Sun Microsystems, Inc.
spacerspacer
spacer www.sun.com docs.sun.com |
spacer
black dot
 
 
5.  Troubleshooting To Resolve Configuration Problems  Previous   Contents   Next 
   
 

To Resolve Applet Downloading Problems

  1. If you see the following message while trying to download the applet on the card, it is possible that you have not added the ATR of the smart card inserted in the reader to the list of valid ATRs the system can accept.

    SmartcardInvalidCardException
  2. Try updating the card's ATR by following the procedure in "To Add Support for a New Card Type (New ATR)".

To Add a Missing ATR

When you try to add a smart card in the Smartcard Console, a screen displays the ATR of the card inserted in the reader. If the ATR displayed does not exist in the list of valid ATRs, add the ATR to the card-name.ATR property.

See "To Add Support for a New Card Type (New ATR)" for more information. See command-line example below.

Example--Adding a Missing ATR (Command Line)

Display ocfserv properties to see if the card_name.ATR property exists.

# smartcard -c admin

For example, ocfserv lists a property MySCM.0.ATR, where MySCM is the user-friendly name of the card reader. This property reflects the ATR of the smart card inserted in the reader. This property is temporary and is added by ocfserv only for the time the card is in the reader. This property is removed when the card is removed.

Add this ATR to the card_name.ATR property if the ATR displayed by this property does not exist in the list of valid ATRs.

 
 
 