Document fins/I0544-2


FIN #: I0544-2

SYNOPSIS: QFE cards installed on Netra t1 servers may experience a fitting
          problem with RJ45 cables.

DATE: May/16/00

KEYWORDS: QFE cards installed on Netra t1 servers may experience a fitting
          problem with RJ45 cables.


---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                            FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)



SYNOPSIS:  QFE cards installed on Netra t1 servers may experience a  
           fitting problem with RJ45 cables.  
             

TOP FIN/FCO REPORT: No 
 
PRODUCT_REFERENCE:  Netra t1 QFE RJ45 Cable
 
PRODUCT CATEGORY:   Server / System Box; 

PRODUCTS AFFECTED:   
  
Mkt_ID   Platform   Model   Description   Serial Number
------   --------   -----   -----------   -------------
Systems Affected
----------------

  -     Netra t1    100     Netra t1 Server       -
  -     Netra t1    105     Netra t1 Server       -
 
X-Options Affected
------------------

X1032A  -           -      OPT INT PCI 10/100BASET NIC   -
X1034A  -           -      OPT QFE PCI CARD W/SW         -

Part Number   Description   Model
-----------   -----------   -----

530-1871-04   CBL, ASSY RJ45-RJ45,4M,CAT5

REFERENCES:

BugId: 4294803
ESC: 523439
MANUAL:  806-1551-10  Netra t1 105 100 installation guide


PROBLEM DESCRIPTION:

A problem has been identified with the Netra t1 model 100 and 105.
The problem reported is difficulty fitting the QFE card in a Netra
t1.  However, upon further investigation,  two separate problems 
have been discovered.


Problem 1:

The PCI gasket design incorporates 'dimples' to ensure good contact
with the PCI card rear panel.  However, an identified design weakness
means that it is possible, without due care, to incorrectly install the
PCI card with its bracket sitting on top of these 'dimples'.  This has
the effect of pushing the PCI board out of alignment with the connector
slot on the chassis creating difficulties inserting two of the four
connectors.


Problem 2:

The second problem identified affects the molded hood variety of RJ45
connectors such as used on cable assembly P/N 530-1871-04.  This
problem is caused by an interference fit between the connector
over-moldings and the Netra t1 chassis and lid.  This problem can cause
the customer to be unable to plug in and or remove the RJ45 connector
to the QFE PCI (described above). A definitive list of cable part
numbers that should not be used is being developed.

These issues have been noted by various customers and are currently
being tracked by escalation 523439 and BugId 4294803.

================================================================
In this -2 update to FINI0544-1, the X1032A x-option has been 
added on the X-Options Affected Section on the FIN.  No update 
needed on both the Problem Description or the Corrective Action.
================================================================


IMPLEMENTATION:
 
         ---
        |   |   MANDATORY (Fully Pro-Active)
         ---    
         
  
         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---



CORRECTIVE ACTION: 

Enterprise Customers installing or replacing a QFE PCI (X1034A) in an
existing Netra t1 model 100 or 105 may avoid the above mentioned QFE
PCI card and RJ45 cable fitting problem by following the recommendation
as shown below:

The recommended solution for Problem 1 is to follow the PCI
installation procedure as described below:

Recommended QFE PCI Card Installation

NOTE: Reference Docs: P/N 806-1551-10, Netra t1 105 100 installation 
      guide.

Step 1: 
-------
a.  Remove the system from the shipping package. OR
b.  Remove the system from the rack if already in use.
 
Step 2:
-------
a.  Remove the Flapjack top cover by removing the screw at the rear  
    and center of the unit. 
b.  Slide top cover back and lift off.  
 
Step 3:
-------
a.  Remove processor baffle located in the rear center of the unit by    
    lifting out.  

Step 4: 
-------
a.  If a PCI card is already installed, unclip the slide retainer from 
    the edge of the card.  
b.  Remove the mid baffle by removing the screw at rear of unit and push 
    towards the drive bays and lift out of unit. 
  
Step 5
------
a.  Remove blanking panel or existing PCI card.

Note: Problem 1 must be addressed first to ensure successful RJ45 cable
      installation for Problem 2.
      

Re-Installing PCI card or new PCI card.
=======================================
 
Please note the key to a successful PCI installation is dependent upon
the PCI card fitting into the PCI connector and remaining in a
horizontal plane.  Great care must be exercised to ensure that the PCI
card does not lift and rest on the PCI gasket dimples which is located
at the rear PCI opening.
 
Note:  A photo reference of the PCI gasket dimples is available as an  
       attachment on the EDISTserver. For access, follow the footnote 
       instructions shown below under Supporting Documents
 
Step 6
------  
a.  A visual inspection should be made to ensure the PCI is installed    
    correctly. 
   
Step 7
------
a.  Re-insert the mid baffle with the slide member attached, and secure with 
    the rear screw.  
b.  Push the slide of the baffle forward to hold the corner of the PCI in 
    place.  

Step 8 
------
a.  Re-install the processor baffle, ensuring tabs in corners locate under 
    rear I/O card.  
   
Step 9
------
Make another visual inspection of the installation and make sure the 
horizontal alignment of the PCI card has been maintained and that no 
cables have been trapped. 
 
Step 10
-------
Reinstall the lid and secure screw at the rear of the unit. 


Now proceed to the recommended cable installation. 
--------------------------------------------------

Installing the PCI card as described in the above steps are the tested 
corrective action to provide a solution to Problem 2 is the use of a 
shielded RJ45 connector cable assembly P/N 530-2093-01. 
 
This cable has been tested at Sun and can be installed and removed from the 
current shipping rev Netra t1 105 and 100 with a QFE PCI card installed.
 
As there is limited space for fingertips within a Netra t form-factor,  
it is advised that the left most port RJ45 connector must be installed 
first, followed by adjacent ports to the right.

The  recommended  solution for Problem 2 is to use the shielded RJ45
cable assembly as shown below:

Cable Assembly 
==============
Part Number   Description   
-----------   -----------  
530-2093-0X   ASY,CBL,SHLD,TP-ENET,RJ45-RJ45

This cable may be obtained by the customer from the Sun Spares Price List  
or by contacting your local Sales Representative.

NOTE:  Enterprise Services Field service Representatives are not authorized
       to provide RJ45 cables to customers.  RJ45 cables are the customers 
       responsibility.
       

COMMENTS: 


--------------------------------------------------------------------------
Implementation Footnote:

i)   In case of MANDATORY FINs, Enterprise Services will attempt to    
     contact all affected customers to recommend implementation of 
     the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical    
     support teams will recommend implementation of the FIN  (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the   
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
  accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "Enterprise Services Documenta- 
  tion" and click on "FIN & FCO attachments", then choose the
appropriate   
  folder, FIN or FCO.  This will display supporting directories/files for 
  FINs or FCOs.
   
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
---------------------------------------------------------------------------  


Copyright (c) 1997-2003 Sun Microsystems, Inc.