27.  Dynamically Configuring Devices (Tasks) SCSI Hot-Plugging With the cfgadm Command SPARC: How to Add a SCSI Device to a SCSI Bus  Previous   Contents   Next 
   
 

SPARC: How to Replace an Identical Device on a SCSI Controller

The following procedure uses SCSI disk c1t4d0 as an example of replacing an identical device on a SCSI controller.

  1. Become superuser.

  2. Identify the current SCSI configuration.

    # cfgadm -al
    Ap_Id                Type          Receptacle   Occupant     Condition
    c0                   scsi-bus      connected    configured   unknown
    c0::dsk/c0t0d0       disk          connected    configured   unknown
    c0::rmt/0            tape          connected    configured   unknown
    c1                   scsi-bus      connected    configured   unknown
    c1::dsk/c1t3d0       disk          connected    configured   unknown
    c1::dsk/c1t4d0       disk          connected    configured   unknown
  3. Replace a device on the SCSI bus with another device of the same type.

    # cfgadm -x replace_device c1::dsk/c1t4d0
    Replacing SCSI device: /devices/sbus@1f,0/SUNW,fas@1,8800000/sd@4,0
    This operation will suspend activity on SCSI bus: c1
    1. Type y at the Continue (yes/no)? prompt to proceed.

      I/O activity on the SCSI bus is suspended while the hot-plug operation is in progress.

      Continue (yes/no)? y
      SCSI bus quiesced successfully.
      It is now safe to proceed with hotplug operation.
    2. Power off the device to be removed and remove it.

    3. Add the replacement device. Then, power it on.

      The replacement device should be of the same type and at the same address (target and lun) as the device to be removed

    4. Type y at the Enter y if operation is complete or n to abort (yes/no)? prompt.

      Enter y if operation is complete or n to abort (yes/no)? y
  4. Verify that the device has been replaced.

    # cfgadm -al
    Ap_Id                Type          Receptacle   Occupant     Condition
    c0                   scsi-bus      connected    configured   unknown
    c0::dsk/c0t0d0       disk          connected    configured   unknown
    c0::rmt/0            tape          connected    configured   unknown
    c1                   scsi-bus      connected    configured   unknown
    c1::dsk/c1t3d0       disk          connected    configured   unknown
    c1::dsk/c1t4d0       disk          connected    configured   unknown

SPARC: How to Remove a SCSI Device

The following procedure uses SCSI disk c1t4d0 as an example of removing a device on a SCSI controller.

  1. Become superuser.

  2. Identify the current SCSI configuration.

    # cfgadm -al
    Ap_Id                Type          Receptacle   Occupant     Condition
    c0                   scsi-bus      connected    configured   unknown
    c0::dsk/c0t0d0       disk          connected    configured   unknown
    c0::rmt/0            tape          connected    configured   unknown
    c1                   scsi-bus      connected    configured   unknown
    c1::dsk/c1t3d0       disk          connected    configured   unknown
    c1::dsk/c1t4d0       disk          connected    configured   unknown
  3. Remove the SCSI device from the system.
    # cfgadm -x remove_device c1::dsk/c1t4d0
    Removing SCSI device: /devices/sbus@1f,0/SUNW,fas@1,8800000/sd@4,0
    This operation will suspend activity on SCSI bus: c1

    1. Type y at the Continue (yes/no)? prompt to proceed.

      Continue (yes/no)? y
      SCSI bus quiesced successfully.
      It is now safe to proceed with hotplug operation.

      I/O activity on the SCSI bus is suspended while the hot-plug operation is in progress.

    2. Power off the device to be removed and remove it.

    3. Type y at the Enter y if operation is complete or n to abort (yes/no)? prompt.

      Enter y if operation is complete or n to abort (yes/no)? y
  4. Verify that the device has been removed from the system.

    # cfgadm -al
    Ap_Id                Type          Receptacle   Occupant     Condition
    c0                   scsi-bus      connected    configured   unknown
    c0::dsk/c0t0d0       disk          connected    configured   unknown
    c0::rmt/0            tape          connected    configured   unknown
    c1                   scsi-bus      connected    configured   unknown
    c1::dsk/c1t3d0       disk          connected    configured   unknown

SPARC: Troubleshooting SCSI Configuration Problems

This section provides error messages and possible solutions for troubleshooting SCSI configuration problems. For more information on troubleshooting SCSI configuration problems, see cfgadm(1M).

Error Message
cfgadm: Component system is busy, try again: failed to offline:
     device path
          Resource              Information
     ------------------  --------------------------
     /dev/dsk/c1t0d0s0   mounted filesystem "/file-system"
Cause

You attempted to remove or replace a device with a mounted file system.

Solution

Unmount the file system that is listed in the error message and retry the cfgadm operation.

If you use the cfgadm command to remove a system resource, such as a swap device or a dedicated dump device, an error messages similar to the following is displayed if the system resource is still active.

Error Message
cfgadm: Component system is busy, try again: failed to offline:
     device path
          Resource              Information
     ------------------  --------------------------
     /dev/dsk/device-name   swap area
Cause

You attempted to remove or replace one or more configured swap areas.

Solution

Unconfigure the swap areas on the device that is specified and retry the cfgadm operation.

Error Message
cfgadm: Component system is busy, try again: failed to offline:
     device path
          Resource              Information
     ------------------  --------------------------
     /dev/dsk/device-name   dump device (swap)
Cause

You attempted to remove or replace a dump device that is configured on a swap area.

Solution

Unconfigure the dump device that is configured on the swap area and retry the cfgadm operation.

Error Message
cfgadm: Component system is busy, try again: failed to offline:
     device path
          Resource              Information
     ------------------  --------------------------
     /dev/dsk/device-name   dump device (dedicated)
Cause

You attempted to remove or replace a dedicated dump device.

Solution

Unconfigure the dedicate dump device and retry the cfgadm operation.

 
 
 