Cisco Broadband Fixed Wireless System Transverter Replacement Instructions

Cisco Broadband Fixed Wireless System Transverter Replacement Instructions

Product Number: CISCO-WT2772-PAA=

This document explains how to remove and replace the wireless transverter component of a Cisco broadband fixed wireless system. It includes instructions for powering down the system, removing an installed transverter, and installing a new transverter.


Note   Use this document in conjunction with the Cisco uBR7200 Series Universal Broadband Router Installation and Configuration Guide and Regulatory Compliance and Safety Information for the Cisco uBR7200 Series Universal Broadband Router that shipped with your Cisco uBR7200 series router, and the Cisco uBR7200 Series Universal Broadband Router Wireless Modem Card and Subsystem Installation and Configuration document that shipped with your broadband fixed wireless modem card.

This document includes the following sections:

If You Need More Information

The Cisco IOS software running on your router contains extensive features and functionality. The effective use of many of these features is easier if you have more information. For additional information on configuring and maintaining the Cisco uBR7200 series router, the following documentation resources are available:

Wireless Transverter Overview

The wireless transverter (often referred to as the outdoor unit or ODU) is the control and data interface to the indoor subsystems. It provides up/down conversion for IF to RF frequencies and power amplification.

The wireless transverter consists of the following components:

Figure 1 shows the connectors on the wireless transverter, and Table 1 describes their use.


Figure 1: Wireless Transverter with Duplexer Assembly Installed



Table 1: Wireless Transverter and Duplexer Assembly Connectors
Connector Type Input/Output Function

Antenna connector

N-type weatherized (female)

Input and Output

Antenna connection

Test

Mono phone (female) 3.5 mm

Output

Measures voltage for antenna alignment

Control

LEMO-type (8-pin, R, 1K series)

Input and output

Provides RF subsystem control interface

IF input

N-type weatherized (female)

Input and Output

Carries receive and transmit IF signals, power, and IF reference frequency

Ground lug

Two-hole compression

Ground

Installation Prerequisites

This section provides a list of parts and tools you need to remove and replace a wireless transverter. This section also includes safety and ESD-prevention guidelines to help you avoid injury to yourself and damage to the equipment.

Parts and Tools

To remove and replace the transverter, you need the following tools and parts. If you need additional equipment, contact a service representative for ordering information.


Note   Some N-type connectors require specific tools. Obtain this information from your cable vendor.

Safety Guidelines

The following are safety guidelines that you should observe when working with any equipment that connects to electrical power or telephone wiring.

Safety Warnings


Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the "Regulatory Compliance and Safety Information" section in this document.

Waarschuwing

Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het gedeelte Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen in dit document.

Varoitus

Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät tämän asiakirjan Regulatory Compliance and Safety Information -osasta (määräysten noudattaminen ja tietoa turvallisuudesta).

Attention

Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez la section Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) de ce document.

Warnung

Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Abschnitt "Regulatory Compliance and Safety Information" (Informationen zu behördlichen Vorschriften und Sicherheit) in diesem Dokument.

Avvertenza

Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nella documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) nel presente documento.

Advarsel

Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i avsnittet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) i dette dokumentet.

Aviso

Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte a secção Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) neste documento.

¡Advertencia!

Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar la sección titulada Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que aparece en este documento.

Varning!

Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Om du vill se översättningar av de varningar som visas i denna publikation, se avsnittet "Efterrättelse av föreskrifter och säkerhetsinformation" i detta dokument.

Electrical Equipment Guidelines

Follow these basic guidelines when working with any electrical equipment.

Telephone Wiring Guidelines

When working with any equipment that is connected to telephone wiring or to other network cabling, use the following guidelines:

Removing and Replacing the Wireless Transverter

To remove and replace the wireless transverter, follow these instructions.


Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. This equipment contains an energy hazard. Disconnect the system before servicing.


Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.


Warning A radiation hazard may exist within a specific radius around the center point of the antenna. Table 2 associates antenna gain (in dBi) with a minimum acceptable distance according to FCC rules. Determine the gain of the antenna and use Table 2 to locate the minimum acceptable distance from the center point of the antenna.


Table 2: Radiation Hazard Calculation (Transmitter Power = 33 dBm)
Antenna Gain
(dBi)
EIRP
(dBm)
EIRP
(W)
Minimum Acceptable Distance under FCC Rules—Uncontrolled Environment (m) Minimum Acceptable Distance under FCC
Rules—Controlled Environment (m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Removing the Wireless Transverter

To remove an installed wireless transverter:

    1. Shut Down the Wireless Link

    2. Disconnect the Power

    3. Remove the Cables

    4. Remove the Wireless Transverter from the Antenna Mast

Shut Down the Wireless Link

The wireless transverter is a required component of the broadband fixed wireless system, and can only be removed when the wireless link is down. Using the procedures established at your installation, shut down the wireless link with the shut command.

Disconnect the Power


Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.

To disconnect the DC power from the wireless transverter:


Step 1   Ensure that the DC power source is disconnected. (See warning above.)

Step 2   Switch the wireless transverter power/breaker switches on the rear panel of the power feed panel to the OFF position. (See Figure 2.)


Figure 2: Wireless Transverter Power/Breaker Switches on Power Feed Panel (OFF)



Remove the Cables


Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last.


TimeSaver To make replacement easier, be sure all cables are labeled.

To remove the cables from the wireless transverter:


Step 1   Remove the RF cable leading to the antenna from the Antenna connection. (See Figure 3.)


Figure 3: Wireless Transverter Cable Connections


Step 2   Remove the IF cable from the IF input connection. (See Figure 3.)

Step 3   Remove the control cable from the Control connection. (See Figure 3.)

Step 4   Remove the two screws securing the ground lug. (See Figure 4.)


Figure 4: Removing the Ground Lug



Remove the Wireless Transverter from the Antenna Mast


Caution Do not leave the transverter unattended with the fasteners removed.

To remove the wireless transverter from the antenna mast:


Step 1   Starting with the shock mounts secured to the lower mounting bracket, remove the four nuts and four washers fastening the shock mount bolts to the upper and lower brackets. (See Figure 5.)


Note   Do not remove the four shock mounts, which remain attached to the transverter. Do not loosen the mounting brackets or remove them from the antenna mast.


Figure 5: Removing the Transverter from the Mounting Brackets


Step 2   Grip the transverter with both hands and pull it away from the mounting brackets until all four of the shock mount bolts are free of the brackets.


Transferring the Duplexer

If you will be transferring the duplexer to a new transverter, remove the duplexer and transfer it to
the new transverter according to the instructions shipped with the duplexer, or the instructions in the Cisco uBR7200 Series Universal Broadband Router Wireless Modem Card Subsystem Installation and Configuration document shipped with your wireless modem card.

Replacing the Wireless Transverter

To replace the wireless transverter:

    1. Install the Duplexer in the Wireless Transverter

    2. Assemble the Shock Mounts

    3. Install the Shock Mounts

    4. Mount the Wireless Transverter on the Antenna Mast

    5. Attach the Cables

    6. Reinstate the Power

    7. Initiate the Wireless Link

Install the Duplexer in the Wireless Transverter

Install the duplexer in the transverter. Refer to the instructions shipped with the duplexer, or the instructions in the Cisco uBR7200 Series Universal Broadband Router Wireless Modem Card Subsystem Installation and Configuration document shipped with your wireless modem card.

Assemble the Shock Mounts

To assemble each of the four shock mounts:


Step 1   Place the hex bolt in the hole in the center of the hex bolt slot in the adapter plate. (See Figure 6.)


Note   The hex bolt slot holds the head of the bolt in place when the nut is fastened to the bolt.


Figure 6: Shock Mount Assembly


Step 2   Place the cupmount on top of the adapter plate, lining up the four corner holes in each.

Step 3   Use the four screws with the square cone washers to attach the cupmount to the adapter plate.


Install the Shock Mounts

To attach each of the four shock mounts to the transverter:


Step 1   Put a split lock washer and a flat washer on each of the four 5/16-hex bolts. The split lock washer goes on first. (See Figure 7.)


Figure 7: Attaching the Shock Mounts to the Transverter


Step 2   Line up the center hole in each cupmount with a mounting hole at the corner of the transverter.

Step 3   Attach each shock mount to the transverter with the hex bolt and washers (see Figure 7), but do not fully tighten the bolts until after the shock mounts are properly aligned. The mounting brackets seat correctly in the mounting bracket slots only when the shock mounts are properly aligned. Improper alignment prevents the mounting bracket from seating correctly, which could allow the shock mount to slide across the mounting bracket and move the transverter.

Step 4   Align each shock mount so that the mounting bracket slot on the shock mount (see Figure 8) is parallel to one of the shorter sides of the transverter. The mounting bracket slots on the upper shock mounts must be parallel to the top of the transverter. The mounting bracket slots on the lower shock mounts must be parallel to the bottom of the transverter.


Figure 8: Shock Mount Alignment


Step 5   Tighten each hex bolt to between 7 and 8 foot-pounds of torque.

Step 6   Make sure that the mounting bracket slot on each shock mount is still positioned correctly.

Step 7   When the shock mounts are attached to the transverter, they must not touch the fins on the back of the transverter. Check all four shock mounts to make sure that none of them is touching the transverter fins. (See Figure 9.)


Figure 9: Shock Mount Positioning



Mount the Wireless Transverter on the Antenna Mast


Caution Do not leave the transverter unattended with the fasteners removed.

To mount the replacement transverter on the antenna mast:


Step 1   Insert the four 3/8-hex bolts extending from the shock mounts into the holes in the upper and lower mounting brackets attached to the mast. (See Figure 10.)


Figure 10: Attaching the Transverter to the Mounting Brackets


Step 2   Push the transverter toward the mast until the mounting brackets mate with the mounting bracket slots on the shock mounts.

Step 3   Make sure that the mounting brackets are seated correctly in the corresponding mounting bracket
slots on all four shock mounts. If a mounting bracket does not seat correctly in the mounting bracket slot on any shock mount, you must loosen the 5/16-bolt fastening the misaligned shock mount to the transverter, realign the shock mount, then secure it again.

Step 4   Make sure that the head of each hex bolt is properly positioned in the shock mount hex bolt slot to keep it from spinning when the nut is tightened. (See Figure 6.)

Step 5   Place a washer and nut on each bolt, then finger-tighten the nut. (See Figure 10.)

Step 6   Make sure that the mounting brackets are still seated correctly in the mounting bracket slots on the shock mounts.

Step 7   Tighten all four nuts to 15 foot-pounds of torque.


Attach the Cables

To attach the cables to the new wireless transverter:


Step 1   Attach the ground lug. (See Figure 11.)


Figure 11: Attaching the Ground Lug


Step 2   Connect the control cable to the control connector. (See Figure 12.)


Figure 12: Wireless Transverter Cable Connections


Step 3   Connect the IF cable to the IF input connector. (See Figure 12.)

Step 4   Connect the RF cable leading to the antenna to the N-type antenna connector in the middle of the duplexer. (See Figure 12.)

Step 5   After the cable connections have been verified, install the cable-connection weatherproofing included with the transverter on the IF and RF cable connections (IF input and Antenna).


Note   Do not use common electrical tape, or similar types of tape, as weatherproofing because the resulting seal is not adequate. These types of tape do not withstand sunlight well. They also leave a gummy residue when they are removed.


Reinstate the Power

To reinstate the power:


Step 1   Reconnect the DC power source.

Step 2   After wiring the DC power supply, remove the tape from the circuit breaker switch handle and reinstate the power by moving the handle of the circuit breaker to the ON position.

Step 3   Switch the wireless transverter power/breaker switches on the rear panel of the power feed panel to the ON position. (See Figure 13.)


Figure 13: Wireless Transverter Power/Breaker Switches on Power Feed Panel (ON)



Initiate the Wireless Link

Reinstate the wireless link using the procedures established at your installation and the no shut command.

This completes the procedure for removing or replacing the wireless transverter in a Cisco broadband fixed wireless system.

Regulatory Compliance and Safety Information

This section provides international agency compliance, safety, and statutory information regarding the removal and replacement of the Cisco broadband fixed wireless system transverter.

FCC Registration and Requirements

The following paragraphs describe requirements and information based on FCC rules.

This Cisco product has been tested and complies with the limits for a Class A digital device, pursuant to Part 15 and Part 21 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, can cause harmful interference to radio transmissions.

This product complies with FCC Class B limits with the use of shielded control cable.

Translated Safety Warnings

This section repeats in multiple languages the warnings found in this document.

Energy Hazard Warning


Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. This equipment contains an energy hazard. Disconnect the system before servicing.

Waarschuwing

Alleen getraind en gekwalificeerd personeel mag deze uitrusting installeren, vervangen of onderhouden. Deze uitrusting bevat energierisico's. Ontkoppel het systeem voordat u het onderhoudt.

Varoitus

Tämän laitteen asennuksen, vaihdon tai huollon saa suorittaa ainoastaan koulutettu ja pätevä henkilökunta. Laitteessa on sähköiskuvaara. Irrota järjestelmä ennen huoltoa.

Attention

Cet équipement ne doit être installé, remplacé ou entretenu que par du personnel d'entretien qualifié et formé. Cet équipement contient de l'énergie électrique potentiellement dangereuse. Débrancher le système avant tout entretien/révision.

Warnung

Gerät nur von geschultem, qualifiziertem Personal installieren, auswechseln oder warten lassen. Im Gerät liegt gefährliche Spannung an. Vor allen Wartungsarbeiten Gerät vom Netz trennen.

Avvertenza

Questo apparato può essere installato, sostituito o revisionato solo da personale qualificato e competente. Questo apparecchio presenta pericolo di scosse elettriche. Scollegare il sistema prima di procedere alla revisione.

Advarsel

Dette utstyret skal bare monteres, skiftes ut eller vedlikeholdes av kvalifisert personell som har gjennomgått opplæring. Det kan være fare for elektrisk støt forbundet med dette utstyret. Kople fra systemet før igangsetting av vedlikeholdsarbeid.

Aviso

Apenas pessoal treinado e qualificado deve ser autorizado a instalar, substituir ou fazer a revisão deste equipamento. Este equipamento constitui risco de choque eléctrico. Desligar o sistema antes de efectuar qualquer serviço de revisão.

¡Advertencia!

Solamente el personal calificado debe instalar, reemplazar o reparar este equipo, ya que existe riesgo de descarga eléctrica. Desenchufe el sistema antes de proceder al mantenimiento del mismo.

Varning!

Endast utbildad och behörig personal får utföra installation, utbyte eller service av denna utrustning. Denna utrustning kan medföra fara för elstöt. Koppla ifrån systemet innan service utförs.

Lightning Activity Warning


Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.

Waarschuwing

Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen.

Varoitus

Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.

Attention

Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.

Warnung

Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert.

Avvertenza

Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.

Advarsel

Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner.

Aviso

Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada).

¡Advertencia!

No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera.

Varning!

Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar.

Potential Radiation Hazard Warning


Warning A radiation hazard may exist within a specific radius around the center point of the antenna. Table 1 associates antenna gain (in dBi) with a minimum acceptable distance according to FCC rules. Determine the gain of the antenna and use to locate the minimum acceptable distance from the center point of the antenna.

Antenna Gain (dBi)
EIRP (dBm)
EIRP (W)
Minimum Acceptable Distance under FCC 
Rules - Uncontrolled Environment (m)
Minimum Acceptable Distance under FCC 
Rules - Controlled Environment(m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Waarschuwing

Binnen een bepaalde afstand tot het centrale punt van de antenne kan sprake zijn van stralingsgevaar. In tabel 1 ziet u de verhouding tussen antennevermogen (in dBi) en minimaal aan te houden afstand volgens FCC-voorschriften. Bepaal het vermogen van de antenne en kijk vervolgens in de tabel welke afstand tot het centrale punt van de antenne minimaal moet worden aangehouden.

Antennevermogen (dBi)
EIRP (dBm)
EIRP (W)
Minimaal aan te houden afstand volgens FCC-voorschriften - Ongecontroleerde omgeving (meters)
Minimaal aan te houden afstand volgens FCC-voorschriften - Gecontroleerde omgeving (meters)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Varoitus

Tietyllä etäisyydellä antennin ympärillä voi olla säteilyvaara. Taulukossa 1 yhdistetään antennin vahvistus (dBi) FCC:n sääntöjen mukaiseen hyväksyttävään vähimmäisetäisyyteen. Määritä antennin vahvistus ja katso taulukosta 1 hyväksyttävä vähimmäisetäisyys antennin keskiöstä.

Antennin vahvistus (dBi)
EIRP (dBm)
EIRP (W)
FCC:n sääntöjen mukainen hyväksyttävä vähimmäisetäisyys - valvomaton ympäristö (m)
FCC:n sääntöjen mukainen hyväksyttävä vähimmäisetäisyys - valvottu Ympäristö(m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Attention

Des risques d'irradiation sont possibles dans un rayon spécifique autour de l'antenne. Le tableau 1 associe le gain d'antenne (exprimé en dBi) à une distance minimale acceptable conformément aux normes de la FCC. Évaluez le gain d'antenne et utilisez le tableau 1 pour déterminer la distance minimale acceptable de l'antenne.

Gain d'antenne (dBi)
PIRE (dBm)
PIRE (W)
Distance minimale acceptable conformément aux normes de la 
FCC - Environnement non contrôlé (m)
Distance minimale acceptable conformément aux normes de la 
FCC - Environnement contrôlé(m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Warnung

In einem bestimmten Umkreis des Antennenmittelpunkts besteht Strahlungsgefahr. In Tabelle 1 ist die Antennenverstärkung (in dBi) in Zusammenhang mit der zulässigen Mindestentfernung laut Bestimmungen der FCC (Bundes-Kommunikations- Kommission der USA) angegeben. Bestimmen Sie die Verstärkung der Antenne, und finden Sie anhand von Tabelle 1 die zulässige Mindestentfernung vom Antennenmittelpunkt heraus.

Antennenverstärkung (dBi)
EIRP (dBm)
EIRP (W)
Zulässige Mindestentfernung nach FCC-Bestimmungen - Unkontrollierte Umgebung (m)
Zulässige Mindestentfernung nach FCC-Bestimmungen - Kontrollierte Umgebung (m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Avvertenza

Potrebbe esistere un pericolo di radiazione all'interno di un raggio specifico attorno al punto centrale dell'antenna. La tabella 1 associa l'aumento di potenza dell'antenna (in dBi) con una distanza accettabile minima secondo i regolamenti FCC. Determinare l'aumento di potenza dell'antenna e usare la tabella 1 per individuare la distanza accettabile minima dal punto centrale dell'antenna.

Aumento di potenza dell'antenna (dBi)
EIRP (dBm) 
EIRP (W) 
Distanza minima accettabile secondo i regolamenti FCC - Ambiente non controllato (m)
Distanza minima accettabile secondo i regolamenti FCC - Ambiente controllato(m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Advarsel

Det kan være strålingsfare innen en viss radius rundt senterpunktet av antennen. Tabell 1 sammenligner antennens kraft (in dBi) med den minste akseptable avstanden i henhold til FCC-direktivene. Finn ut antennens kraft og bruk Tabell 1 til å lokalisere den minste akseptable avstanden fra senterpunktet av antennen.

Antennekraft (dBi)
EIRP (dBm)
EIRP (W)
Minste akseptable avstand ihht. FCC-direktiv - Ukontrollert miljø (m)
Minste akseptable avstand ihht. FCC-direktiv - Kontrollert Miljø (m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Aviso

Pode existir perigo de radiação dentro de um raio específico no ponto central da antena. A Tabela 1 associa o ganho de antena (em dBi) a uma distância mínima aceitável de acordo com as normas FCC. Determine o ganho da antena e utilize a Tabela 1 para localizar a distância mínima aceitável a partir do ponto central da antena.

Ganho de antena (dBi)
EIRP (dBm)
EIRP (W)
Distância mínima aceitável ao abrigo das normas FCC - Ambiente não controlado(m)
Distância mínima aceitável ao abrigo das normas FCC - Ambiente controlado (m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

¡Advertencia!

Existe riesgo de radiación en un área específica alrededor del punto central de la antena. La Tabla 1 asocia la ganancia de antena (en dBi) con una distancia mínima aceptable de acuerdo con las normas de la FCC. Determina la ganancia de la antena y utiliza la Tabla 1 para establecer la distancia mínima aceptable desde el punto central de la antena.

Ganancia de la antena (dBi)
PIRE (dBm)
PIRE (W)
Distancia mínima aceptable según las normas de la FCC - Entorno sin control (m)
Distancia mínima aceptable según las normas de la FCC - Entorno controlado(m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

Varning!

Strålningsrisk kan finnas inom en angiven omkrets runt antennens mittpunkt. Tabell 1 visar riktfaktor (i dBi) med ett minsta godtagbart avstånd enligt FCC-reglerna. Avgör antennens riktfaktor och använd Tabell 1 för att hitta minsta godtagbara avstånd från antennens mittpunkt.

Riktfaktor (dBi)
EIRP (dBm)
EIRP (W)
Minsta godtagbara avstånd enligt FCC-reglerna - Ej kontrollerad miljö (m
Minsta godtagbara avstånd enligt FCC-reglerna - Kontrollerad miljö(m)

10

43

20.0

0.4

20 cm

11

44

25.1

0.4

20 cm

12

45

31.6

0.5

20 cm

13

46

39.8

0.6

0.3

14

47

50.1

0.6

0.3

15

48

63.1

0.7

0.3

16

49

79.4

0.8

0.4

17

50

100.0

0.9

0.4

18

51

125.9

1.0

0.4

19

52

158.5

1.1

0.5

20

53

199.5

1.3

0.6

21

54

251.2

1.4

0.6

22

55

316.2

1.6

0.7

23

56

398.1

1.8

0.8

24

57

501.2

2.0

0.9

25

58

631.0

2.2

1.0

26

59

794.3

2.5

1.1

27

60

1000.0

2.8

1.3

28

61

1258.9

3.2

1.4

29

62

1584.9

3.6

1.6

30

63

1995.3

4.0

1.8

DC Power Disconnection Warning


Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.

Waarschuwing

Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het gelijkstroom circuit uitgeschakeld is. Om u ervan te verzekeren dat alle stroom UIT is geschakeld, kiest u op het schakelbord de stroomverbreker die het gelijkstroom circuit bedient, draait de stroomverbreker naar de UIT positie en plakt de schakelaarhendel van de stroomverbreker met plakband in de UIT positie vast.

Varoitus

Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista. Varmistaaksesi, että virta on KATKAISTU täysin, paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.

Attention

Avant de pratiquer l'une quelconque des procédures ci-dessous, vérifier que le circuit en courant continu n'est plus sous tension. Pour en être sûr, localiser le disjoncteur situé sur le panneau de service du circuit en courant continu, placer le disjoncteur en position fermée (OFF) et, à l'aide d'un ruban adhésif, bloquer la poignée du disjoncteur en position OFF.

Warnung

Vor Ausführung der folgenden Vorgänge ist sicherzustellen, daß die Gleichstromschaltung keinen Strom erhält. Um sicherzustellen, daß sämtlicher Strom abgestellt ist, machen Sie auf der Schalttafel den Unterbrecher für die Gleichstromschaltung ausfindig, stellen Sie den Unterbrecher auf AUS, und kleben Sie den Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest.

Avvertenza

Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non sia alimentato. Per verificare che tutta l'alimentazione sia scollegata (OFF), individuare l'interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere l'interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.

Advarsel

Før noen av disse prosedyrene utføres, kontroller at strømmen er frakoblet likestrømkretsen. Sørg for at all strøm er slått AV. Dette gjøres ved å lokalisere strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på strømbryteren i AV-stilling.

Aviso

Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua. Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF (Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.

¡Advertencia!

Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF). Para asegurarse de que toda la alimentación esté cortada (OFF), localizar el interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automático en posición de Apagado (OFF).

Varning!

Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.

Ground Connection Warning


Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last.

Waarschuwing

Bij installatie of vervanging van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt.

Varoitus

Laitetta asennettaessa tai korvattaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.

Attention

Lors de l'installation ou du remplacement de l'appareil, la mise à la terre doit toujours être connectée en premier et déconnectée en dernier.

Warnung

Der Erdanschluß muß bei der Installation oder beim Austauschen der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden.

Avvertenza

In fase di installazione o sostituzione dell'unità, eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo.

Advarsel

Når enheten installeres eller byttes, må jordledningen alltid tilkobles først og frakobles sist.

Aviso

Ao instalar ou substituir a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a última a ser desligada.

¡Advertencia!

Al instalar o sustituir el equipo, conecte siempre la toma de tierra al principio y desconéctela al final.

Varning!

Vid installation eller utbyte av enheten måste jordledningen alltid anslutas först och kopplas bort sist.

Obtaining Documentation

World Wide Web

You can access the most current Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.

Documentation CD-ROM

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM is updated monthly. Therefore, it is probably more current than printed documentation. The CD-ROM package is available as a single unit or as an annual subscription.

Ordering Documentation

Registered CCO users can order the Documentation CD-ROM and other Cisco Product documentation through our online Subscription Services at http://www.cisco.com/cgi-bin/subcat/kaojump.cgi.

Nonregistered CCO users can order documentation through a local account representative by calling Cisco's corporate headquarters (California, USA) at 408 526-4000 or, in North America, call 800 553-NETS (6387).

Obtaining Technical Assistance

Cisco provides Cisco Connection Online (CCO) as a starting point for all technical assistance. Warranty or maintenance contract customers can use the Technical Assistance Center. All customers can submit technical feedback on Cisco documentation using the web, e-mail, a self-addressed stamped response card included in many printed docs, or by sending mail to Cisco.

Cisco Connection Online

Cisco continues to revolutionize how business is done on the Internet. Cisco Connection Online is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information and resources at anytime, from anywhere in the world. This highly integrated Internet application is a powerful, easy-to-use tool for doing business with Cisco.

CCO's broad range of features and services helps customers and partners to streamline business processes and improve productivity. Through CCO, you will find information about Cisco and our networking solutions, services, and programs. In addition, you can resolve technical issues with online support services, download and test software packages, and order Cisco learning materials and merchandise. Valuable online skill assessment, training, and certification programs are also available.

Customers and partners can self-register on CCO to obtain additional personalized information and services. Registered users may order products, check on the status of an order and view benefits specific to their relationships with Cisco.

You can access CCO in the following ways:

You can e-mail questions about using CCO to cco-team@cisco.com.

Technical Assistance Center

The Cisco Technical Assistance Center (TAC) is available to warranty or maintenance contract customers who need technical assistance with a Cisco product that is under warranty or covered by a maintenance contract.

To display the TAC web site that includes links to technical support information and software upgrades and for requesting TAC support, use www.cisco.com/techsupport.

To contact by e-mail, use one of the following:

Language
E-mail Address

English

tac@cisco.com

Hanzi (Chinese)

chinese-tac@cisco.com

Kanji (Japanese)

japan-tac@cisco.com

Hangul (Korean)

korea-tac@cisco.com

Spanish

tac@cisco.com

Thai

thai-tac@cisco.com

In North America, TAC can be reached at 800 553-2447 or 408 526-7209. For other telephone numbers and TAC e-mail addresses worldwide, consult the following web site: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.

Documentation Feedback

If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco.

You can e-mail your comments to bug-doc@cisco.com.

To submit your comments by mail, for your convenience many documents contain a response card behind the front cover. Otherwise, you can mail your comments to the following address:

Cisco Systems, Inc.
Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate and value your comments.





hometocprevnextglossaryfeedbacksearchhelp