This chapter describes making the interface connections between a VNS and the Cisco StrataCom node (IGX or IPX) and the StrataView Plus workstation. It includes the following sections:

Physical Interfaces

After you have rack mounted the VNS and connected the power, you must connect the physical interfaces to it. These interfaces, which are shown in Figure 6-1, are:


Note The Frame Relay Card is only connected to a node when there are multiple VNS service areas (or domains) in the network.

Figure 6-1:
VNS Physical Interfaces



Figure 6-1 illustrates the VNS directly connected to an IGX node. With an IGX, the Frame Relay Card is connected to an FRM in the IGX, and the E1 NICs are connected to an CVM cards. If the directly connected node were an IPX the Frame Relay Card would be connected to an FRP (Frame Rely PAD), and the E1 NICs would be connected to CDPs (Channelized Data PADs).

There are slight differences in the location of the interface connections on VNS-AC and VNS-DC models and VNS-AC-E and VNS-DC-E models. Figure 6-2 shows the location of the connectors for the VNS-AC physical interfaces; the interface connectors are in the same location on a VNS-DC model. Figure 6-3 shows the location of the interface connectors for VNS-AC-E physical interfaces; the interface connectors are in the same location on a VNS-DC-E model.


Figure 6-2: VNS-AC Interface Connectors




Figure 6-3:
VNS-AC-E Interface Connectors



Connecting a Terminal

You can attach a terminal (or PC running a terminal emulation program, such as ProCom), to the VNS to perform some of the configuration locally.

Attach your terminal cable, typically a null modem cable, to the A/B (Terminal) connector on the VNS's back panel, as shown in Figure 6-2 (or Figure 6-3). This is an asynchronous ttya port on the UNIX-based VNS. Your terminal or PC and emulation software must be set to match the VNS's communication parameters:

Caution A terminal (or PC) which has been connected to a VNS-AC or VNS-DC A/B (Terminal) port should not have its power recycled because this can cause the VNS to enter a different mode.

The VNS terminal port has been set up at the factory. If you have trouble displaying VNS files and menus cleanly, you might reset the following parameters:

stty rows 24
stty erase ^h
setenv TERM vt100

Also if you are connected to the VNS through an XTERM session, you should run the following command:

eval 'resize' or resize

This lets XTERM know about the number of rows and columns.

Connecting the E1 NICs to the Node

The E1 NICs (Channelized E1) connect to either an IGX's CVM with a BC-E1 back card, or an IPX's CDP with a BC-E1 back card. Each E1 NIC has two 75-ohm BNC connectors, one for transmit and one for receive, as shown in Figure 6-4. (Figure 6-2 illustrates which E1 NIC is referred to as Voice Port 1 and which is referred to Voice Port 2.)

To connect an E1 NIC to the node, follow these steps:

Step 1 Determine which physical port on the node is considered Voice Port 1. This port will be connected to Voice Port 1 on the VNS as shown in Figure 6-2 (or Figure 6-3).

Step 2 Connect a 75-ohm coax cable from the transmit (TX) connector on the VNS's E1 NIC to the RX (receive) connector on the node's CDP/CVM BC-E1 card.

Step 3 Connect a 75-ohm coax cable from the receive (RX) connector on the VNS's E1 NIC to the TX (transmit) connector on the node's CDP/CVM BC-E1 card.

Step 4 If both E1 NICs are being connected to the node, repeat Steps 1 to 3 for Voice Port 2 and the second E1 NIC in you VNS.


Figure 6-4: E1 NIC Rear Panel



Configuring the Voice Port on the Node

The Voice Port on the node is either a IGX's CVM or a IPX's CDP. These cards must be upped and configured, with the upcd (up card), upcln (up circuit line), and cnfcln (configure circuit line) commands, like any other card on the IGX or IPX. You can find detailed descriptions of the IGX or IPX's command line interface in the Cisco StrataCom Command Reference.

At the node (i.e., IGX/IPX), the circuit line between the node and the VNS should be configured with the cnfcln (configure circuit line) command for:

Figure 6-5 illustrates a typical IGX cnfcln menu with the parameters set for connecting to a VNS E1 NIC.

The signaling channels over this physical interface are configured through the VNS command line interface, covered in Chapter 7, Understanding the VNS Configuration Interface, and Chapter 8, VNS Network Operation.


Figure 6-5: E1 Configuration for CVM Port connected to E1 NIC
supigx1        TN    StrataCom       IGX 16    8.4.15    Feb. 22 1998 16:17 GMT 
 
CLN 8 Configuration   E1/31                 CVM slot: 8                         
Loop clock:           No                  
                                          
Line framing:         --                  
     coding:          HDB3                
     CRC:             No                  
     recv impedance:  75 ohm + gnd        
     E1 signalling:   CCS                 
     encoding:        A-LAW               
     T1 signalling:   --                  
     cable type:      --                  
     length:          --                  
     56KBS Bit Pos:   msb                 
     pct fast modem:  100                 
                                          
                                                                                
Last Command: cnfcln 8 N HDB3 N 1 100
 
 
Next Command: 

Connecting the Frame Relay Card to the Node

The Frame Relay Card is used to connect to other VNSs when there are multiple VNS service areas. The Frame Relay Card (RS449 connector) connects to an IGX's FRM with a Frame Relay Interface (FRI) V.35 (or X.21) back card, or an IPX's FRP with a Frame Relay Interface V.35 (or X.21) back card. The Frame Relay Card has an RS449 physical connector.

Cisco supplies two types of cables to connect the Frame Relay Card to the node. One cable has an RS449 connector for the VNS and a V.35 connector for the node's V.35 Frame Relay Interface (back card). The other cable has an RS449 connector for the VNS and an X.21 connector for the node's X.21 Frame Relay Interface (back card). These cables are ordered independently along with the VNS.


Note If there is only a single VNS area in your network, the Frame Relay card does not have to be connected to the node. The RS449 physical connector, however, should be terminated with a loopback connector.

To connect the VNS's Frame Relay Card to the node, follow these steps:

Step 1 Connect the RS449-end of the cable (ordered with the VNS) to the RS449 connector on the VNS, shown in Figure 6-2 (or Figure 6-3).

Step 2 Connect the V.35- or X.21-end of the cable to the appropriate port on the node's Frame Relay Interface (V.35 or X.21) back card.

Configuring the Frame Relay Port

The frame-relay LMI parameters for the VNS side of the frame-relay connection to the node (IGX, IPX, etc., ) are set in a UNIX file, fr_config. This factory has configured this file for no LMI. If you wish to choose Strata-LMI or Annex D LMI, follow these steps:

Step 1 Log in to the VNS.

Step 2 If they are running, stop the VNS processes using the VNS CLI as described in Chapter 5 in the section Shutting Down the VNS.

Step 3 Change directory (cd) to /usr/net/fr.

Step 4 Execute ./frstop

Step 5 Edit (vi) fr_config.

Step 6 Change the following line (configuration line at the beginning of the file):

HOST RS449 clock 0 N393 0 INARP NO
to ONE of the following forms:
HOST RS449 clock 0 GOF N393 4 INARP NO 		 		# Strata-LMI
HOST RS449 clock 0 N393 4 INARP NO        	 #  Annex D

Step 7 Save the modified fr_config file (:ZZ).

Step 8 Execute ./frstart

Step 9 Restart the VNS processes.

The LMI default Timer/Counter values are:

The default values should be appropriate for most applications. If needed, these values may be changed by inserting the appropriate identifier-and-value pair in the configuration line (similar to the "N393 4" Step 6 above).

The node's Frame Relay Port must be upped and configured, with the upfrport (up Frame Relay Port) and cnffrport (configure Frame Relay Port) commands, like any other port on the node. You can find detailed descriptions of using the IGX or IPX's command line interface in the Cisco StrataCom Command Reference.

You must also configure the Frame Relay Port (FRP, FRM, FRSM) to match the LMI set on the VNS. Depending on the type of node, the node's Frame Relay Port will be configured with the appropriate IPX, IGX, AXIS configuration command, such as cnffrport for an IGX FRM. Figure 6-6 illustrates a typical Frame Relay Port configured for no LMI.


Figure 6-6: Frame Relay Port Configuration
supigx1        TN    StrataCom       IGX 16    8.4.15    Feb. 22 1998 16:23 GMT 
 
Port:       3.1               [INACTIVE]
Interface:  FRI-V35 DCE                       Configured Clock:   256 Kbps
Clocking:   Normal                            Measured Rx Clock:    0 Kbps
                                       Min Flags / Frames           1
Port ID                        0
Port Queue Depth           65535       OAM Pkt Threshold            3 pkts
ECN Queue Threshold        65535       T391 Link Intg Timer        10 sec
DE Threshold                 100 %     N391 Full Status Poll        6 cyl
Signalling Protocol         None       EFCI Mapping Enabled        No
Asynchronous Status           No       CLLM Enabled/Tx Timer   No/  0 msec
T392 Polling Verif Timer      15       IDE to DE Mapping          Yes
N392 Error Threshold           3       Interface Control Template
N393 Monitored Events Count    4          Lead    CTS    DSR    DCD
Communicate Priority          No          State   ON     ON     ON
Upper/Lower RNR Thresh  75%/ 25%
                                                                                
Last Command: dspfrport 3.1
 
 
Next Command: 
 

Note that the Frame Relay port at the other end (the other VNS) will also have to be configured. The Frame Relay connection between these two VNSs will be built through the VNS Configuration Interface which is described in Chapters 7 and 8. The connection will default to a Frame Relay Class of Service 1. The Cisco StrataCom Command Reference contains detailed information about Frame Relay classes.

Modifying the Default Range of VNS DLCIs

The VNS's Frame Relay Port comes from the factory with DLCIs 101 to 113 configured for use. These DLCIs are used for establishing Frame Relay PVCs between VNSs in different VNS areas. If you need to use a DLCI other than 101 to 113, you will have to add it to the fr_conv file. This applies to both the local and remote ends of the Frame Relay PVC between the VNSs.

These DLCIs are used by the VNS Configuration Interface and are described in Chapter 7 in the section, Local Adjacency Information.


Note You should not modify fr_conv unless you are sure you need to use a DLCI which is not in the default range.

To modify the default range of DLCIs used for PVCs between VNSs in different VNS areas, follow these steps:

Step 1 Log in to the VNS on which you need to add a DLCI. This could be either the local or the remote VNS.

Step 2 If they are running, stop the VNS processes using the VNS CLI as described in Chapter 5 in the section Shutting Down the VNS.

Step 3 Change directory (cd) to /usr/net/fr.

Step 4 Execute ./frstop

Step 5 Edit (vi) fr_conv. A typical fr_conv file is shown below:

Sample fr_conv File
# ADAX Frame Relay IP address to DLCI (0, . . . , 1023) to port mapping
#
# Note: ports 0-7 are physical, upper ports 8-15 are for protocol layers
#   connected to the Frame Relay Multiplexer package (i.e. TCP/IP).
#
# IP Address    Frame Relay DLCI        Port
# 189.0.0.1     123                     0
# 189.0.0.2     234                     0
# 189.0.0.3     0x345                   2       # Hex-coded DLCI is OK
# 189.0.0.4     0x345                   2       # Same DLCI
# 1             456                     3       # SNA encapsulation
# 2             567                     3       # X.25 encapsulation
# 189.0.0.6     678                     8       # Local TCP/IP home port
#
# The following examples would only be used if Frame Relay were operating as
# network and performing Frame Relay switching.  This is a rarely used option.
#
# Lines that begin with a dash (-) indicate a port-to-port DLCI and port number
# mapping.  Each entry consists of five fields, including the dash.  The second
# through fifth fields are the source DLCI and port, and the destination DLCI
# and port.
#
#                 Source      Destination
#              DLCI   Port     DLCI   Port
# -             25      0       22      1       # software <-> hardware
# -             30      0       39      2       # demo <-> software
# -             30      1       40      2       # demo <-> hardware
# -             31      3       41      2       # bacchus <-> hardware
# -             33      3       43      0       # bacchus <-> eng_lab
# -             134     0       144     7       # software <-> Dial-up
# -             135     1       45      7       # hardware <-> Dial-up
# -             136     3       46      7       # bacchus <-> Dial-up
# -             137     5       47      7       # silenus <-> Dial-up
# -             38      5       48      3       # silenus <-> bacchus
-               100     0       100     9       # silenus <-> bacchus
-               101     0       101     9       # silenus <-> bacchus
-               102     0       102     9       # silenus <-> bacchus
-               103     0       103     9       # silenus <-> bacchus
-               104     0       104     9       # silenus <-> bacchus
-               105     0       105     9       # silenus <-> bacchus
-               106     0       106     9       # silenus <-> bacchus
-               107     0       107     9       # silenus <-> bacchus
-               108     0       108     9       # silenus <-> bacchus
-               109     0       109     9       # silenus <-> bacchus
-               110     0       110     9       # silenus <-> bacchus
-               111     0       111     9       # silenus <-> bacchus
-               112     0       112     9       # silenus <-> bacchus
-               113     0       113     9       # silenus <-> bacchus

The lines at the end of the file that began with a dash (-) indicate a port-to-port DLCI and port number mapping. These are the DLCIs reserved for the Frame Relay connections to the VNS's Frame Relay Port. Each entry consists of five fields, including the dash. The second through fifth fields are the source DLCI and port and the destination DLCI and port.


Step 6 To add another DLCI for use at this VNS's Frame Relay Port, add it at the end of the file. For instance to add DLCI to the range of DLCIs available, you would enter:

-               114    0        114     9        # additional DLCI 114

Step 7 Add all the DLCIs that you need to the end of this file.

Step 8 Save the modified fr_conv file (:ZZ).

Step 9 Execute ./frstart.

Step 10 Execute ./frroute.

Step 11 Restart the VNS processes.

Connecting to an Ethernet Segment

The VNS connects to an ethernet to communicate both with the node, the IPX Nodal Processor Card (NPC), or the IGX Nodal (i.e., Network) Processor Module (NPM), and with an SV+ Workstation. Figure 6-7 illustrates the ethernet connections.


Figure 6-7: Ethernet Connection



Normally the VNS is connected from its 10Base-T connector (see Figure 6-2) to an Ethernet Hub. (The 10Base-T Ethernet Hub is not supplied by Cisco.) The node's LAN port and the SV+ Workstation are also connected to this same ethernet segment.


Note If the SV+ Workstation is collecting statistics, it is recommended that it not be connected to the same ethernet segment as the VNS and the node. The heavy statistics traffic can affect the operation of VNS.

Local LAN Environment

You may have to modify some of the VNS's UNIX operating system (i.e., Solaris 2.4) files for your local LAN environment. To do this, you will need to use a text editor such as vi to modify files and a few simple Sun operating system (SunOS) commands.

Using vi

vi is a UNIX-based screen editor which can be used to make some minor modifications to the UNIX-based files. You can find out more about vi, by typing man vi at the VNS's UNIX prompt and pressing Enter. In vi there is a command mode and an editing (i.e., insertion) mode. Most commands are entered from the command mode; while the file is actually modified in the editing mode. You quit the editing mode with ESC. Since only minor changes need to be made to VNS UNIX files, you should only need to know a few commands:

When you are logged in to the VNS, you can find out the use and syntax of operating system commands with the man page command; for instance, enter man login to find out about the login command.

A quick procedure for editing any of the files:

Step 1 cd to where the file is located.

Step 2 vi filename.

Step 3 Position cursor where you want to add or change text (use the arrow keys or h, j, k, l).

Step 4 Enter o to add a new line, i to edit a line, or R to enter overwrite mode.

Step 5 Enter your text.

Step 6 Hit ESC when you are done adding text. You are now back in the command mode.

Step 7 Enter ZZ to save the file. (You can use more filename to check that file has been modified).


Note If you are uncomfortable with vi, you might copy the (cp) the original file to another name before editing it; for example, cp filename newfilename.

Modifying LAN (Ethernet) Parameters


Note The local LAN parameters can be very involved, particularly if NIS+ is running on your network. These UNIX-based files should only be modified by an experienced system administrator who is familiar with the Solaris 2.4 operating system.

After checking with your system administrator, set the IP address, hostname, and other parameters necessary for operating the VNS in your local area network environment, as follows:

Step 1 Connect a terminal to the VNS.

Step 2 Log in to VNS as superuser.


Note Once you start changing host names and IP addresses, you must make sure you complete all the files. Do not turn off power or reboot in the middle of this process or you could disable your VNS.

Step 3 Use vi to screen edit the file /etc/hosts and add the IP address for VNS and the IP address for the SV+ Workstation.

For direct Ethernet connection where, for example, you have an SV+ Workstation with a hostname of nms and an IP address of 200.1.2.3 and a VNS with a hostname of ins1 and an IP address of 200.1.2.4, you would add the two lines, shown in bold type, to the hosts file:


Contents of /etc/hosts
#
127.0.0.1	localhost
#
200.1.2.4	ins1	loghost	# INS1 (VNS 1 local Ethernet port) 
200.1.2.3	nms		# SV+ Workstation
#192..x.x.x	fr-ins1	 frhost	# INS1 (Frame-Relay)
# End of hosts
Note that the frhost (frame-relay host) IP address is used for remote SV+ Workstation connectivity and can be commented out by adding a # sign to beginning of line. This feature is not used with the VNS.

Step 4 If required for your local network, use vi to screen edit the file /etc/networks, which will appear similar to the following:

Contents of /etc/networks file:
#
# The loopback network is used only for intra-machine communication
#
loopback	127
#
# Internet networks
#
arpanet	10	arpa	# Historical
nms-net	200.1.2		# SV+ network
# End of networks
For our example, the line in bold text, nms-net . . ., is added to the networks file.

Step 5 If required for your local network, use vi to screen edit the file /etc/netmasks to add the appropriate subnet mask for your LAN segment.

Step 6 If required for your local network, use vi to screen edit the file /etc/hostname.le0 to name the VNS's ethernet port.

Step 7 If required for your local network, use vi to screen edit the file /etc/nodename to name the VNS node, and verify that this name is the same name as /etc/hostname.le0.

Step 8 Use the date SunOS command to set the local date and time.

Step 9 Set the VNS's local timezone by editing /ect/TIMEZONE file. Table 6-1 lists the supported time zones. Open the file (with vi) and look for the line:

Change this line to the required TimeZone;
for example:


Save the /etc/TIMEZONE file .


Step 10 Execute the reboot command to restart the VNS.


Note For VNS operation, the /etc/defaultrouter file should be empty.

Note Note that the UNIX ifconfig command could be used to configure the VNS's Ethernet port IP address. So for our example:

ifconfig le0 200.1.2.4

This should not be necessary if the IP address has been added to /etc/hosts.


Remote StrataView Plus Workstation


Table 6-1: Supported Time Zones
Australia/ Brazil/ CET CST6CDT Canada/
Chile/ Cuba EET EST EST5EDT
Egypt Erie Etc/ Factory GB
GB-Eire GMT GMT+0 GMT+1 GMT+10
GMT+11 GMT+12 GMT+13 GMT+2 GMT+3
GMT+4 GMT+5 GMT+6 GMT+7 GMT+8
GMT+9 GMT-0 GMT-1 GMT-10 GMT-11
GMT-12 GMT-2 GMT-3 GMT-4 GMT-5
GMT-6 GMT-7 GMT-8 GMT-9 Greenwich
HST Hongkong Iceland Iran Israel
Jamaica Japan Kwajalein Libya MET
MST MST7&MDT Mexico/ Mideast NZ
NZ-CHAT Navajo PRC PST8PDT Poland
ROC ROK Singapore Turkey UCT
US/ UTC Universal W-SU WET
Zulu posixrules


For the following you need to enter both country/area (for example, US/Eastern)


For Australia:

ACT Broken_Hill LHI NSW North
Queensland South Tasmania Victoria West
Yancowinna


For Brazil:

Acre DeNoronha East West


For Canada:

Atlantic Central East-Saskatchewan Eastern Mountain
Newfoundland Pacific Yukon


For Chile:

Continental EasterIsland


For Etc:

GMT GMT+0 GMT+10 GMT+11 GMT+12
GMT+2 GMT+3 GMT+4 GMT+5 GMT+6
GMT+7 GMT+8 GMT+9 GMT-0 GMT-1
GMT-10 GMT-11 GMT-12 GMT-13 GMT-2
GMT-3 GMT-4 GMT-5 GMT-6 GMT-7
GMT-8 GMT-9


For Mexico:

BajaNorte BajaSur General


For Mideast:

Riyadh87 Riyadh88 Riyadh89


For US:

Alaska Aleutian Arizona Central East-Indiana
Eastern Hawaii Michigan Mountain Pacific
Pacific-New Samoa

Where the VNS and the StrataView Plus Workstation are not on the same Ethernet, they must communicate over a frame-relay connection. In this case, the SV+ Workstation and the VNS are connected to separate Ethernet segments, as shown in Figure 6-8.


Figure 6-8: Connectivity Using Two Ethernet Segments



In the situation shown in Figure 6-8, the messages from the VNS to the SV+ (i.e., SNMP Traps) are routed over Ethernet 2 to Router 2 to the StrataCom Network to Router 1 to Ethernet 1 to the SV+ Workstation. The only configuration that needs to be done is to provide the route from the VNS to the SV+ Workstation on the IP network. Consult your network administrator for help in setting up this route over the routers.

Multiple Remote VNSs

When there are multiple VNSs in the network, a separate ethernet connection will have to be made between each VNS and the SV+ Workstation as shown in Figure 6-9. Your network administrator should assist you in setting up these connections over the additional routers.


Figure 6-9: Multiple VNSs



Connecting the Redundant VNS

When configuring redundancy, do not switch on the redundant VNS until the active unit is fully configured. You connect the redundant VNS, or second VNS in a redundant pair, in exactly the same way as you did with the first VNS. As shown in Figure 6-10, the second VNS uses identical physical interfaces:

The Frame Relay Card and E1 NICs physical connections will be to different physical ports on the IGX/IPX node, although these ports do not necessarily have to be on separate cards.

The second VNS will also have to have its local LAN environment set up, and it will use a different IP address and host name than the first VNS.


Figure 6-10: Redundant VNS




Note The Frame Relay Card connection is only used when there are multiple VNS areas in your network. Since this feature is not supported in VNS Release 1.0, this connection will not be made when connecting the redundant VNS.

Configuring the Node

When adding Voice Network Switching (VNS) to a StrataCom network, the node connected to the VNS may require some high-level adjustments to its operating parameters. These parameters are adjusted with:

Table 6-2 lists these commands and the parameters that can have an effect on the operation of a VNS network.

Caution The cnfnodeparm and cnfcmparm are superuser-level commands and should be used carefully. And, although the cnftrk command is not superuser-level command, it should also be used carefully. Note that these parameter changes can adversely affect your network's operation. They should be adjusted only after your network has been carefully modeled.

Table  6-2: Configuring the Node Commands
Command Parameter Adjustment
cnfnodeparm Nw Pkt Tx Rate (pps)
Network Packet Transmit Rate
The default of 500 packets per second can be changed to 1000 packets per second.
cnfcmparm 17 Max SVC Retry1

18 Send SVC urgent msg1

Should be set to 5.

Should be set to Yes.

cnftrk Statistical Reserve The Statistical Reserve for trunks connecting to the VNS node should be doubled.
  1. The cnfnodeparm and cnfcmparm commands are described in detail in the Cisco StrataCom SuperUser Command Reference.
  2. The cnftrk command is described in detail in the Cisco StrataCom Command Reference.

  3. 1. In switched software release 8.5, Max SVC Retry and Send SVC urgent msg parameters apply only to IPX nodes.

SNMP Community Names

Each of the nodes (i.e., Cisco-StrataCom switches) in the network need to have their SNMP community names set up before Voice Network Switching will work. You should ensure that the Cisco-StrataCom nodes and network have seen set up for proper IP connectivity. If necessary, refer to the Release 8.4 Cisco StrataCom Command Reference or Cisco StrataCom SuperUser Command Reference and use the following commands:

Adding Network IP Routes

The VNS must be able to communicate with each node in the network. If there is not an Ethernet connection to each node, the VNS can communicate with the nodes through IP Relay. This involves setting up the Network IP addresses (cnfnwip), creating a Network IP (NWIP) subnet, and adding the gateway to that subnet with the route add net command on the VNS. (The route add net command can be stored in a file at /etc/rc3.d that executes at system startup time.)

For instance in Figure 6-11, IGX 1 is connected to the same Ethernet segment as VNS 1. IGX 1 has a LAN IP address of 200.1.2.5. The other three IGX's (IGX2, 3, and 4) will communicate with VNS 1 using IP Relay. This IP Relay network will have become a subnet with address 200.200.200.0. Traffic from VNS 1 to IGX 2, 3, or 4 has to be directed out the Network IP (NWIP) subnet (200.200.200.0) through IGX 1. In effect IGX 1 serves as a gateway to the NWIP subnet.


Figure 6-11: Network IPs



To configure this sample NWIP subnet, you would follow these steps:

Step 1 The Network IPs (NWIP) for each of the four nodes will have to be configured with each node's cnnwip command. (They are all be put on the same subnet with the subnet mask argument, 255.255.255.0.)

Step 2 Next you would log into the VNS and create a file containing the UNIX-level route add net command. The command is:

route add net 200.200.200.0 200.1.2.5 1


Where 200.200.200.0 is the network address of the NWIP subnet, and 200.1.2.5 is the LAN address of IGX 1. Note that there is a space between the two IP addresses and a space between the second IP address and the 1. The 1 after the second IP address is a hop metric and must be non-zero if the destination is not directly connected to the VNS's Ethernet segment.


This file with the route add net command should saved in /etc/rc3.d and could be named S70route, as in this example file:


/etc/rc3.d more s70route
#Sample S70route file
#route add default xxx.xxx.xxx.xxx #if applicable, add the address of the default router
route add net 200.200.200.0 200.1.2.5 1
#
# End

This file executes at system startup.


Migrating Voice Connections to a VNS Network

Often Voice Network Switching is added to a Cisco StrataCom wide area network which has previously been configured for voice connections. When migrating voice connections to a VNS network, you should consider the following commands which may have to be adjusted:

cnfchgn (Configure Channel Gain)

cnfchadv (Configure Channel Adaptive Voice)

cnfecparm (Configure Integrated Echo Cancellor Parameters)

The cnfchgn and cnfchadv commands are described in the Cisco StrataCom Command Reference in the Chapter on Voice Connections. The cnfecparm command is a superuser-level command and is described in the Cisco StrataCom SuperUser Command Reference. Note that the cnfecparm command is used to set the Voice Template parameter, which selects either normal level (USA) or high-level (UK) voice.

Ping the VNS

After you have connected and configured the VNS(s), you should log in (or have someone log in) to the SV+ Workstation and Ping the VNS to ensure that they are communicating. You should also be able to ping all the remote nodes.

The rest of the configuration of a VNS network is done with the VNS Configuration Interface, described in Chapter 7. Chapter 8, VNS Network Operation, describes using the VNS Configuration Interface to provision the VNS network.

Adding a VNS Object to the SV+ Topology Maps

After you determine that StrataView Plus and the VNS are communicating (as a result of Ping), you need to install a network map icon, which represents either the VNS or its redundant VNS, on the topology maps of the SV+ Workstation. A VNS icon is added, modified, or deleted only through HP OpenView. This icon shows only the existence of the VNS; StrataView Plus does not manage the VNS object. StrataView Plus does receive SNMP Traps from the VNS, however, and will display the status of the VNS with different colors:

Green Normal
Yellow Minor alarm
Red Major alarm
Brown VNS unreachable

The VNS icon is only visible on the SV+ Workstation where it was added.

To add a VNS icon, which requires access to the HP OpenView network topology main menu on the SV+ Workstation, follow these steps:

Step 1 At the SV+ Workstation open an HP OpenView window (at the UNIX prompt, change to the OV directory, then enter ovw).

Step 2 Double-click your network icon to open a Network Topology window and map, shown in Figure 6-12.


Figure 6-12: HP OpenView Network Topology Map



Step 3 Select the Edit - Add Object... menu.
The Add Object: Palette window appears.

Step 4 Click on the StrataView icon on the Add Object: Palette to open the Symbol Subclasses window where you will find the VNS icon as shown in Figure 6-13.


Figure 6-13: Add Object: Palette and VNS (DNS) icon



Step 5 Using the middle mouse button, drag and drop the VNS symbol from the Palette to the map as shown in Figure 6-14. The Add Object window appears.


Figure 6-14: VNS Icon on HP OpenView Topology Map



Step 6 In the Add Object window, shown in Figure 6-15, you name the VNS object and call up another window to set its object attributes by identifying the StrataCom node to which it is attached. To name the VNS object:

Set to Yes to display the name of the symbol.
Set to No if you do not want to see an object label on the map.
Selecting Explode causes the submap to display when the symbol is double-clicked.
Selecting Execute permits the symbol to execute an application which performs an action on a set of objects when it is double-clicked.

Figure 6-15: Add Object Menu




Note HP OpenView on-line help explains the difference between explodable and executable symbols.

Step 7 Next Select DAS/DNS Config in the Object Attributes: box. This will activate the Set Object Attributes... button.

Step 8 Click the Set Object Attributes... to present the Add Object - Set Attributes window, shown in Figure 6-16, for DAS/DNS Config. The host name of the VNS that you entered in the previous window will appear in the VNS Node Name box.


Figure 6-16: Add Object - Set Attributes Window



Step 9 In the next three boxes, you enter information about the StrataCom node to which the VNS is attached:


Note Although these boxes are labeled with IPX, they refer to any StrataCom node to which the VNS attaches.

Step 10 If you have entered your information correctly, press the Verify button. The OK button will activate.

Step 11 Press the OK button, you will return to the Add Object window. Press the OK button on the Add Object window and you will return to the HP OpenView network topology map.

Removing the VNS Object From the Topology Map

You must use the StrataCom pull down menu to remove an INS icon from a network topology map. Using any of the other HP OpenView tools, such as Edit--Delete, will cause an error.

To remove the INS icon from you network topology map, follow these steps:

Step 1 With your network topology map displayed, select the VNS icon on the map.

Step 2 Pull down the StrataCom menu from the top menu bar.

Step 3 Select Remove DNS Station from the StrataCom pull down menu.

Adding VNS Users

With this release, user-access verification has been added to the VNS Configuration Interface (i.e., vnscli). In other words, the use of the VNS Command Line Interface is password controlled. The password control has been added through a UNIX-Level vns_passwd file.

Adding a user with specific privileges takes two steps:


  1. Add a UNIX User

  2. Add the VNS User

Adding UNIX users and controlling the vns_passwd file should typically be done by your system administrator.

Add a UNIX User

The system administrator generally adds UNIX users with the Solaris admintool. With its graphical user interface, the admintool simplifies adding users to UNIX operating systems, a task which previously had to be done with the adduser command and by editing the /etc/group file.

To add a UNIX user, the system administrator would follow these steps:

Step 1 From the StrataView Plus Workstation, rlogin or telnet to the VNS.

Step 2 Log in to the VNS as root.

Step 3 At the root prompt, type admintool. The Administration Tool opening screen will appear.

Step 4 Click on the User Account Manager button. The User Account Manager window appears.

Step 5 Press the Edit button and select the Add User option. This will bring up the User Information window.

Step 6 Fill in the username, userid, and the various options. There is a Help button on the menu that provides information about the various options.

Step 7 Press the Add button. The UNIX user now has been added to the VNS.

Add the VNS User

VNS users can be added only after they are UNIX users. The VNS user is added by editing the file /etc/vns_passwd and adding an entry for the VNS user. The entry in the vns_passwd file has the following format:

VnsUserName:Permissions

VnsUserName is the username of the VNS user and must be the same as the one used for the UNIX user which was just added. Permission is the string which specifies the various VNS CLI operations which the user will be permitted to perform. The valid permission options are each specified by a single letter, that is 'a' or 'd' or 'm' or 'b' or 'g' and provide the following permissions:

The two fields must be separated by ':' , the field separator.

A sample factory-default VNS password (vns_passwd) file is shown below:

vns_passwd File
#################################################################
#		This is the passwd file which determines user access to the VNS 
#		database which should exist in /etc.
#
#		The sample format given below has to be adhered to for adding 
#		new users.
#
#		format	:	user_login_id:permissions
#
#		"permissions" can be a string of any of the letters 'a', 'd', 'm',
#		'b', 'g', 'v' which stand for add, delete, modify, browse, debug and validate
#		respectively. These can be specified in any order.
#
#		The user will be allowed to perform only the operations specified
#		by the permission string, on the VNS database using the vnscli.
#
#		The entry for root has been added by default. This line may be 
#		yanked and the required number of users and their permissions
#		may be added. A user not listed in this file is not allowed to 
#		run vnscli. vnscli also does not run if this file is not present.
#
#		A '#' in the first column of a line turns the line into a comment.
#		Users may be deleted by commenting out the corresponding line also.
#
##################################################################
root:amdbgv:

This vns_passwd file shows the root as having all available vnscli privileges (amdbg) as described in the dns_passwd file's comments. To add other users and privilege levels, you edit the file /etc/vns_passwd and add users as shown below:

########################
root:amdbg:
njones:admb:
bsmith:b:
pnirmel:admbv:

Each user is added as a line in the file with the associated privilege levels. In the example above, njones has add, delete, modify, and browse privileges and nsmith has browse (read only) privileges. Save the vns_passwd file after you have added additional VNS users. If the file /etc/vns_passwd does not exist, the VNS Command Line Interface (vnscli) will only operate in the browse mode.


Note The debug privilege 'g' should be reserved for Product Support.