These release notes provide information about Cisco StrataView Plus 9.1.10 for AIX that has changed since the publication of the supporting documentation.
This release note contains the following sections:
The following documents, along with these release notes, make up the Cisco StrataView Plus 9.1 documentation set:
To install patch 2 of SV+ 9.1.07 for AIX, complete the following steps:
Step 1 Login as user svplus.
Step 2 Stop core processes by entering 2 from the SV+ Main Menu.
Step 3 Copy the compressed patch file to the SV+ workstation.
Step 4 Login as user root.
Step 5 Uncompress the patch file by entering the following command:
# uncompress patch_file
Step 6 Extract the contents of the uncompressed patch file by entering the following command:
# tar xvf uncompressed_patch_file
Step 7 Activate the SNMP agent by entering the following commands:
# cd /usr/users/svplus
# ./INSTALL_AGENT
Step 8 Logout as user root and login as user svplus.
Step 9 Start core processes by entering 1 from the SV+ Main Menu.
The 9.1.10 Cisco StrataView Plus for AIX software release supports the existing Cisco WAN switching products (including the Cisco IGX 8400 series and the Cisco BPX 8600 series) running the Switch software version 9.1 based release, and introduces the following features:
x21InvertClock OBJECT-TYPE SYNTAX INTEGER { normal(1), invert(2), normalDontExpectRcvClk(3), invertDontExpectRcvClk(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object configures two options: a) Whether you want to invert the clock sent with the TX data b) Whether you expect to receive a clock from the other side normal(1) - a)=dont invert, b)=expect rcv clock invert(2) - a)=invert, b)=expect rcv clock normalDontExpectRcvClk(3) - a)=dont invert, b)=dont expect rcv clock invertDontExpectRcvClk(4) - a)=invert, b)=dont expect rcv clock Default is normal(1) " ::= { x21CnfGrpEntry 9 }
| Connection Category | SV+ Service Type | Remote Card Group Type | Limits |
|---|---|---|---|
ATM-FR | atfst | FR | Local end point should be on a routing node. Remote end point should be on a feeder node. |
ATM-FR | atftfst | FR |
|
ATM-FR | atfxfst | FR |
|
ATM-ATM | atfst | ATM | Both end points should be on routine nodes. |
ATM-ATM | atftfst | ATM |
|
ATM-ATM | atfxfst | ATM |
|
| Card Group Type | Cards in the Card Group |
|---|---|
FR | FRSM (4T1,4E1,8T1,8E1), FRM, UFM, FRP |
ATM | ASI, ASI-155, BXM, UXM |
| Old Name | New Name |
|---|---|
BPX | BPX 8600 |
IGX | IGX 8400 |
AXIS | MGX 8220 |
| Connection Category | Supported Cards | Service Type |
|---|---|---|
ATM-FR | BXM-FRSM AUSM-FRSM | VBR3 ABRFS |
ATM-ATM | BXM-BXM AUSM-BXM AUSM-AUSM | ABR1 ABRFS VBR1 VBR2 VBR3 CBR1 VBR1 |
Service MIB UPC Paramenter Name | Description |
|---|---|
atmEndPointIBS | Initial Burst Size |
atmEndPointVcQSize | Maximum VC queue depth |
atmEndPointEfciQSize | The threshold setting used by the explicit congestion notification feature for this end-point's transmit queue |
atmEndPointHiCLP | CLP (Cell Loss Priority) tagging activation threshold |
atmEndPointLoCLP | CLP (Cell Loss Priority) tagging deactivation threshold |
Category | CWM Service Type | Local End Point Card Group Type | Remote End point Card Group Type | Restriction/Comments |
|---|---|---|---|---|
ATM-ATM | ABR.FS | UXM/BXM/AUSM | UXM/BXM/AUSM | atmEndPointIBS is not applicable |
ATM-ATM | ABR.1 | UXM/BXM | UXM/BXM | only with VSVD enabled atmEndPointIBS is not applicable |
ATM-ATM | ABR.1 | AUSM | AUSM | atmEndPointIBS is not applicable |
ATM-ATM | ATFST | UXM/BXM/AUSM | UXM/BXM/AUSM |
|
ATM-FR | ABR.FS | UXM/BXM/AUSM | FRSM/UFM | atmEndPointIBS is not applicable |
ATM-FR | ATFST | UXM/BXM/AUSM | FRSM/UFM |
|
ATM-FR | ABR.FS | UXM/BXM/AUSM | FRP/FRM | Connection is not supported |
ATM-FR | ATFST | UXM/BXM/AUSM | FRP/FRM | Connection is not supported |
| Variable | Time (seconds) | Link Number |
|---|---|---|
link0 keep-alive interval | 120 | if number_of_link0 < 29 |
| 180 | if 30 < number_of_link0 < 59 |
| 240 | if 60 < number_of_link0 < 89 |
| 300 | if 90 < number_of_link0 |
link1 keep-alive interval | 300 |
|
.
| Software | Release | Patch | Y2K compliance Certified By | Remarks |
|---|---|---|---|---|
StrataView Plus | 9.1.07 | N/A | Cisco Systems 29 Test Case suite |
|
NetView | 5.1 | N/A | IBM |
|
WINGZ | 2.5 | N/A | IISC |
|
Informix | 7.2.3.UC4 | N/A | Informix |
|
AIX OS | 4.1.5/4.2 | For 4.1.5 the required patches are IX83425 IX79576 IX81658 For 4.2 the required patches are IX82633 IX83741 IX79576 IX81658 | IBM |
|
The StrataView Plus Release 9.1 Connection Manager supports CESM ports, structured and unstructured connections and supports CESM 8 port cards. Until SV+ 9.0 the addressing scheme used for CESM 4 port cards was logical addressing. In SV+ 9.1 the addressing scheme has been changed to physical addressing.
The StrataView Plus Release 9.1 Connection Manager supports management of UXM ports and connections.
The network will allow up to 12 SV+ stations to be connected into it. There is no change in StrataView Plus Release 9.1 software for this feature, the switch software and AXIS (4.04 onwards) have increased their limits to support this.
StrataView Plus Release 9.1.10 will be able to manage 40 different disjoint networks running switch software releases 8.2, 8.4, 8.5 or 9.1 provided all the networks elements have unique network IP addresses and unique names across all the networks managed by StrataView Plus. Different networks may run different versions of switch software as long as the releases are those listed above.
New Features Supported
CESM-(8T1/8E1): Connection Manager and service agent are enhanced to support CESM ports, structured and unstructured connections and to support CESM 8 port cards. Until SV+ 9.0 the addressing scheme used for CESM 4 port cards was logical addressing. In SV+ 9.1 the addressing scheme has been changed to physical addressing.
Table 4 lists the versions of switch software and firmware required to support various front and back cards on specific hardware platforms.
| Platform | Front Card | Back Card | Firmware version | Software version |
|---|---|---|---|---|
IGX 8400 | NPM | SCM | CVJ,CWP | 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | NTM | BC-T1/E1/SR/Y1 |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | BTM | AIT-T3/E3/E2/HSS1/E1 | AJF,BCF,BDK,BDL | 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | FRM | FRI-T1/E1/V.35/X.21 |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | FTM | FPC-V35/T1/E1/X.21 |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | HDM | SDI V.35/RS-449/RS-232C/RS-232D | CEF | 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | LDM | LDI RS-2324/RS-2328/RS-232D |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | CVM | BC-T1/E1/J1/Y1/SR | AFF,AHF,BHC | 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | UVM | UVI-2T1EC/2E1EC |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | UFM-C | UFI-8T1/8E1-DB15,UFI-8E1-BNC |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | UFM-U | UFI-V35/X21/HSI |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | ALM-A | BC-UAI-1E3/1T3 |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | ALM-B | BC-UAI-1T3 /1E3 |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | ARM | ARI | BA | 9.1.00 to 9.1.10 or later releases of 9.1 |
IGX 8400 | UXM | UAI-4OC3MMF/40C3SMF/2OC3SMF/6T3/6E3/3T3/3E3/8T1-IMA/8E1-IMADB15/8E1-IMABNC | AAB,ENW,P0512 | 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | BCC | BCC-bc/3-bc | B0406,BKF,BKJ,BMH,BYJ | 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | ASM | LM-ASM | AAA,ABA,ACA,BC03 | 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | BNI-T3 | LM-3T3 | CCJ,CEL,CHD,CHF | 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | BNI-E3 | LM-3E3 | CFD,CFF,CLF | 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | BNI-155 | LM-OC3-SMF/SMFLR/MMF |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | ASI-1 | LM-2T3/2E3, | BDK,BFJ,BXJ | 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | ASI-155 | LM-2OC3-SMF/SMFLR/MMF | CB30,HFA | 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | BXM-T3/E3 | BPX-T3/E3-BC |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | BXM-15 5 | MMF/SMF/SMFLR-155 | DC1,DL1 | 9.1.00 to 9.1.10 or later releases of 9.1 |
BPX 8600 | BXM-622 | MMF/SMF/SMFLR-622 |
| 9.1.00 to 9.1.10 or later releases of 9.1 |
MGX 8220 | FRSM-4 | DB-15-4T1/4E1, BNC-4E1 | 2.1.16e | 4.0.00 to 4.0.19, 4.1.00 to 4.10.3 |
MGX 8220 | CESM-4 | DB-15-4T1/4E1, BNC-4E1 | 3.0.00 | 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | AUSM-4 | DB-15-4T1/4E1, BNC-4E1 | model-A 2.0.01 | 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | FRSM-8 | RJ48-8T1/8E1, SMB-8E1 |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | AUSM-8 | RJ48-8E1/8T1 |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | CESM-8 | RJ48-8T1/8E1, SMB-8E1 |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | IMATM-B | RJ48-T3T1/E3E1/E3T1/T3E1 |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | FRSM-HS1 | HSI-4X21/3HSSI/V.35 |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | BNM-T3/E3 | T3E3-B/D |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | BNM-155 | 155-SMF |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | SRM | DB-15-T1/E1, LM-3T3 |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
MGX 8220 | ASC | ASC-LM |
| 4.0.00 to 4.0.19, 4.1.00 to 4.1.03 |
The endpoint Policing Parameter in the strata.mib is atmEndptPolicing. This parameter specifies the traffic policing for the ATM endpoint. The following table provides
| Policing Type | 1st Bucket | 2nd Bucket |
|---|---|---|
vbr.1 | CLP(0+1) | CLP(0+1) |
vbr.2 | CLP(0+1) | CLP(0) |
vbr.3 | CLP(0+1) | CLP(0) with CLP Tagging |
pcrplc | CLP(0+1) | none |
none | none | none |
ATM endpoint policing is applicable only to the following connection types:
The following service types support policing:
| Category | SV+ Service Type | Local endpoint Card Group Type | Remote endpoint Card Group Type | Value of Policing | Comments |
|---|---|---|---|---|---|
ATM-ATM | CBR.1 | ATM | ATM | pcrplc(4) |
|
ATM-FR | CBR.1 | ATM | FR | pcrplc(4) | not in 9.1 |
ATM-ATM | VBR.1 | ATM | ATM | vbr1(1) |
|
ATM-ATM | RTVBR1 | ATM | ATM | vbr1(1) | not in 9.1 |
ATM-ATM | VBR2 | ATM | ATM | vbr2(2) |
|
ATM-ATM | RTVBR2 | ATM | ATM | vbr2(2) | not there in 9.1 |
ATM-FR | VBR2 | ATM | FR | vbr2(2) | not there in 9.1 |
ATM-FR | RTVBR2 | ATM | FR | vbr2(2) | not there in 9.1 |
ATM-ATM | VBR3 | ATM | ATM | vbr3(3) |
|
ATM-ATM | RTVBR3 | ATM | ATM | vbr3(3) | not there in 9.1 |
ATM-FR | VBR3 | ATM | FR | vbr3(3) |
|
ATM-FR | RTVBR3 | ATM | FR | vbr3(3) | not there in 9.1 |
ATM-ATM | ABR.FS | ATM | ATM | vbr3(3) |
|
ATM-FR | ABR.FS | ATM | FR | vbr3(3) |
|
ATM-ATM | ABR.1 | ATM | ATM | Can be set to any value between 1 and 5 for ASI family ASI, BXM, BME, UXM | VSVD enabled |
ATM-ATM | ABR.1 | ATM | ATM | not set | VSVD not enabled |
ATM-ATM | ATFST | ATM | ATM | Can be set to any value between 1 and 5 for ASI family | not there in 9.2 |
ATM-FR | ATFST | ATM | FR | Can be set to any value between 1 and 5 for ASI family | not there in 9.2 |
ATM-FR | ATFTFST ATFXFST | ATM | FR | vbr3(3) | not there in 9.2 |
ATM-ATM | ATFTFST ATFXFST | ATM | ATM | vbr3(3) | not there in 9.2 |
UPC parameters can be specified only through the Proxy, not through Connection Manager GUI. If a connection is added from the Connection Manager GUI, default UPC parameter values are used. If a connection is modified from the Connection Manager GUI, UPC parameters remain unchanged. Table 7 provides the Service MIB UPC parameters and their description.
| UPC Parameter | Description |
|---|---|
atmEndPointIBS | Initial Burst Size |
atmEndPointVcQSize | Maximum VC queue depth |
atmEndPointEfciQSize | The threshold setting used by the explicit congestion notification feature for this endpoint's transmit queue |
atmEndPointHiCLP | CLP (Cell Loss Priority) tagging activation threshold |
atmEndPointLoCLP | CLP (Cell Loss Priority) tagging deactivation threshold |
| ATM endpoint UPC Parameter | Column Used in Table 9 |
|---|---|
VcQ Depth | 1 |
EfciQSize | 2 |
IBS | 3 |
CLP Hi | 4 |
CLP Lo | 5 |
Oe Vc Depth | 6 |
Oe EfciQSize | 7 |
Oe IBS | 8 |
Oe CLP Hi | 9 |
Oe CLP Lo | 10 |
| Category | SV+ Service Type | Local endpoint Card Group Type | Remote endoint Card Group Type | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 1 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ATM-ATM | ABR.FS | UXM/BXM | UXM/BXM | x | x |
| x | x | x | x |
| x | x |
ATM-ATM | ABR.FS | AUSM | AUSM | x | x | x | x | x |
|
|
|
|
|
ATM-ATM | ABR.1 with VSVD enabled | UXM/BXM | UXM/BXM | x | x |
| x | x | x | x |
| x | x |
ATM-ATM | ABR.1 with VSVD disabled | Any ATM | Any ATM |
|
|
|
|
|
|
|
|
|
|
ATM-ATM | ABR.1 | AUSM | AUSM | x | x | x | x | x |
|
|
|
|
|
ATM-ATM | ATFST | UXM/BXM | UXM/BXM | x | x | x | x | x | x | x | x | x | x |
ATM-ATM | ATFST | AUSM | AUSM | x | x | x | x | x |
|
|
|
|
|
ATM-FR | ABR.FS | UXM/BXM | FRSM/UFM | x | x |
| x | x | x | x |
| x | x |
ATM-FR | ABR.FS | AUSM | FRSM/UFM | x | x | x | x | x |
|
|
|
|
|
ATM-FR | ATFST | UXM/BXM | FRSM/UFM | x | x | x | x | x | x | x | x | x | x |
ATM-FR | ATFST | AUSM | AUSM | x | x | x | x | x |
|
|
|
|
|
ATM-FR | ABR.FS | UXM/BXM | FRM/FRP (Feeder) | x | x |
| x | x | x | x |
| x | x |
ATM-FR | ABR.FS | AUSM | FRM/FRP (Feeder) | x | x | x | x | x |
|
|
|
|
|
ATM-FR | ATFST | UXM/BXM | FRM/FRP (Feeder) | x | x | x | x | x | x | x | x | x | x |
ATM-FR | ATFST | AUSM | FRM/FRP (Feeder) | x | x | x | x | x |
|
|
|
|
|
ATM-FR | ABR.FS | UXM/BXM | FRM/FRP (Routing and NIW) | x | x | x | x | x | x | x | x | x | x |
ATM-FR | ATFST | AUSM | FRP/FRM (Routing and NIW) | x | x | x | x | x |
|
|
|
|
|
ATM-FR | ABR.FS | UXM/BXM/AUSM | FRP/FRM (Routing and SIW) | x | x | x | x | x |
|
|
|
|
|
ATM-FR | ATFST | UXM/BXM/AUSM | FRP/FRM (Routing and SIW) |
|
|
|
|
|
|
|
|
|
|
SV+ Service Agent is packaged along with StrataView Plus and is not an optional feature. SNMP Agent and Proxy processes are run along with other StrataView Plus core processes. The option to run SNMP agent from the SV+ menu has been removed.
CiscoView is not on the SV+ 9.1 CD. CiscoView consists of CiscoView engine and device package files. CiscoView engine, device package files and required patches of CiscoView engine are on a separate CD included in SV+ bill of materials. CiscoView device package files are also available on CCO and the AXIS/BPX/IGX device files are also available on SV+ CD.
Three types of machines are supported for StrataView Plus 9.1.10 as standard platforms. They are low-end, mid-range and high-end platforms. The configuration of each platform type is listed in Table 10. Other equivalent platforms running AIX 4.2 are also supported.
Machine Type | IBM Power PC model 42T or E30 |
Number of CPUs | 1 |
Size of RAM | 256 MB |
Graphic Card Type | 24 bits |
Hard Disk Space | Two 2 GB drives OR one 4 GB drive |
Swap Space | 512 MB |
Number of SV+ Desktops | less than five |
Number of Connections | less than 5,000 |
The selection of a proper SV+ platform depends on a number of factors, such as number of SV+ desktops, number of managed connections and number of statistics collected and stored. The above table also lists recommended SV+ platforms based on the size of network.
The following are additional notes for SV+ platform requirements:
If a Low End SV+ system is used for mid-range or large-range networks, the following problems may be observed.
Three types of machines are supported for SV+ 9.1 stand-alone SCM as standard platforms. They are low-end, mid-range and high-end platforms. The configuration of each platform type is listed in Table 11.
| Machine Type | Number of CPUs | Amount of RAM | Hard Disk Drive | Size of Swap Space |
|---|---|---|---|---|
IBM Power PC Model 42T or E30 | 1 | 128 MB | One 2 GB drive | 256 MB |
The SV+ 9.1 release works with IBM NetView Release 5.0 for AIX 4.1.5/AIX 4.2
For IBM NetView installation requirements and procedures, please refer to appropriate IBM documentation.
The default color of the background map can make it difficult to see the color of the nodes and the trunks on the map. To change the color of the background map, see See "Default Color of Background Map"
Make sure at least 750 MB of disk space in /usr/users/svplus area can be allocated for SV+ 9.1.10 installation. In the case of upgrade, disk space used by existing SV+ software plus free disk space should exceed 750 MB.
If you have installed SV+ 9.1.00, remove the Informix package from your system and reinstall Informix package from 9.1.10 CD. Make sure Informix processes are not running before removing the informix package. To remove the existing informix package, execute the command as a root user:
# pkgrm CSCOinf
You do not have to remove the Informix package if you had installed Informix from 9.1.01 or later CD.
If you plan to use auto install and intend to partition the disk during auto install you have two choices for installing Wingz:
1. Install Wingz in /opt/Wingz before installing SV+ and then execute IntegrateWingz.
2. Install Wingz in /usr/users/Wingz after installing SV+ and then execute IntegrateWingz.
If you do not plan to partition the disk during auto install or if you are using manual install you have two choices for installing Wingz:
1. Install Wingz either in /usr/users/Wingz or /opt/Wingz before installing SV+.
2. Install Wingz either in /usr/users/Wingz or /opt/Wingz after installing SV+ and run IntegrateWingz.
Install Wingz software from the Wingz tape or CD. Note that WingZ version 2.5 should be installed for SV+ release 9.1.10. After installing, contact Wingz for a runtime license and blend it with SV+ 9.1.10. Failing to do so will result in following error message when clicking on the SV+ Report icon: "There is a problem with the registration information for this machine. Contact your system administrator".
If Informix is installed on a disk array (typically the device name is /dev/vx/rdsk/rootdg/vol03) then the ownership of the device and the group ownership of the device should be set to informix. The mode of the device should be 770. Otherwise, after reboot the machine, the following error message will appear in the console, "Shared memory is not initialized".
If you are installing HP/OV 5.01 over an existing version make sure that the /etc/snmpd and /etc/snmpd.conf files are removed or re-named before carrying out the upgrade. If these files are not removed or renamed, it is likely that you will see the following message when trying to re-start OV:
object manager name: netmon behavior: OVs_WELL_BEHAVED state: NOT_RUNNING PID: - last message: Can't talk to snmpd; see /usr/OV/log/netmon.trace for info exit status: exit(1)
Information left in these files causes problems for the new version of OV.
These files are not removed by the ovremove program.
The SV+ upgrade is not supported across different platforms. For example, an AIX-based SV+ release cannot be upgraded to a Solaris based SV+ release or vice versa. The following upgrades are not supported in this version (9.1.10):
The SV+ 8.2 or 8.4 or SV+ 9.0 to SV+ 9.1 upgrade is supported.
After performing the creation of a new database by executing the SV+CreateDb command, if StrataView Plus is restarted before it is synchronized with the network, it will result in a database inconsistency. In this case, perform create_db before restarting SV+ to avoid database inconsistency.
The logical_connection table count for a node in SV+ database may not match the master lcon counts in that node. This will happen if the database contains FastPAD connections, or if the database has slave lcons with no connections.
If Gateway node is upgraded or rebuilt, before SV+ has synchronized with the network, SV+ needs to be cold-started (created SV+ database and restart SV+). This is required to ensure SV+ database consistency.
SV+ database and network may differ by value 1 for parameters PCR(0+1), SCR(0+1), MCR, ICR of some ATM-FR conceitedness. This happens because of the difference (rounding effect) in conversion algorithms used by SV+ and switch to convert values in cells/sec units to 100 bit/sec units.
SV+ CM GUI has text fields for the parameters PCR(0+1), SCR(0+1), MCR and ICR (all in the unit of cell/sec) on the ATM side of the ATM - FR ABR.FS provision window.
The front-end application (CM GUI) passes these values to the back-end process to setup the SNMP request PDU for the switch agent. Following are the MIB variable and the association value from the GUI:
| MIB Variable | GUI Association |
|---|---|
atmEndptPCR | PCR(0+1) |
atmEndptSCR | SCR(0+1) |
atmEndptMCR | MCR |
atmEndptQIR | IC |
After the SNMP set request to the switch is done, the values will be deposited in the user_connection table. Following are the database table column names:
| Field in user_connection Table | GUI Association |
|---|---|
l_pir (100 bit/sec) | PCR(0+1) |
l_cir (100 bit/sec) | SCR(0+1) |
l_mir (100 bit/sec) | MCR |
l_qir (100 bit/sec) | IC |
Since the unit for those four columns are in 100 bit/sec, conversion from cell/sec to 100 bit/sec is done. The conversion algorithm results in 100 bps = ((384 * cps) + 99) / 100 as shown in the following table:
| cell/second | 100 bit/second |
|---|---|
50 | 192 |
5760 | 22119 |
3259 | 12515 |
2834 | 10883 |
The conversion factor used by the switch (in this case BPX 9.1) is different from that used by SV+. Therefore, after the ConnObj Robust Message update, the user_connection table would have different values for those 4 columns. See the following table with example values:
| Cell/second | SV+ 100 bit/second | Switch 100 bit/second |
|---|---|---|
5760 | 22119 | 22118 |
3259 | 12515 | 12514 |
2834 | 10883 | 10882 |
SV+ database, intermittently, may have incomplete connections for the following reasons. When a multi-segment PVC is being added, if a node receives connection add request, but doesn't respond to SV+, SV+ backs out all the segments from the other nodes which have responded to the add request and deletes those segments from the StrataView DB. The node which didn't respond ends up having that segment. Because of this, any further attempt to add that connection, after the node becomes reachable, results in 'connection already exists' error in StrataView. However, this connection segment may or may not appear in SV+ database, depends on which node was not responsive. Here are the two example scenarios:


In Figure 1 and Figure 2, F1, F2 are feeder shelves, and S1 and S2 are switch nodes. If S1 becomes unreachable after receiving an add request from SV+ but before sending the response back, 'middle segment' will be added on S1 between S1 and S2. However, the connection segment details will not be there in SV+ database. After S1 becomes reachable, configuration changes will be sent to StrataView and StrataView database will be updated with the middle segment details. You can delete the incomplete connection at this time, using StrataView.
However, if F1 (or F2) is Axis shelf and it becomes unreachable after receiving add connection segment request, SV+ doesn't get updated with the end segment details, even if the node becomes reachable. The database update happens whenever the next periodic Node Resync by SV+ happens with that shelf.
Similar DB inconsistency can happen in case of delete connection operation. In this case, while a multi-segment PVC is being deleted, if a node receives connection delete request, but doesn't respond to SV+, SV+ doesn't delete this segment information from the database. This results in a dangling connection segment in SV+ DB, which doesn't exist on the node. However, this connection segment will be deleted from SV+ database eventually. The time taken for this database synch-up once the node become reachable, depends on the type of the node.
In the Figure 1 and Figure 2, if S1 becomes unreachable after receiving delete request from SV+, but before sending the response back, 'middle segment' will be deleted on S1, between S1 and S2. However, this connection segment details will not be deleted from SV+ database. Once S1 becomes reachable configuration changes will be sent to StrataView and StrataView database will be updated accordingly.
However, if F1 (or F2) is an Axis shelf and it becomes unreachable after receiving delete connection segment request, SV+ doesn't delete the end segment details from the DB, even if the node becomes reachable. The database update happens whenever the next periodic Node Resync by SV+ happens with that shelf.
Any node with IP address 192.0.0.0 or 0.0.0.0 will not be displayed or stored in SV+ database. In order to configure the correct network IP address use cnfnwip command on the switch.
Each IPX/BPX/IGX/MGX 8220 node to be managed by StrataView Plus must be configured with an IP Relay IP Address (cnfnwip). The gateway node must be configured with both LAN and IP Relay IP Addresses.
The IPX/BPX routing and IPX/AF feeder modes must be configured with read and write SNMP community names. The SNMP community names "public" and "private" are configured in SV+ for GET and SET respectively as defaults.
The directly attached node (Gateway node) must be configured with IP Relay IP address before starting StrataView Plus.
Node names, IP Addresses and NWIP addresses of the nodes in a network and across networks in multiple networks scenarios, should be uniquely configured.
For adding a connection, the connectionIndex must be 0 (there is no need to do a GET on connAvailIndex). The actual index is internally generated by the connection service agent itself.
For DAS connections, deleting an end point from a segment and later adding it to another segment at a very fast rate may result in a database inconsistency.
Test Connection and Test Delay do not work for connections routed through a Cisco virtual trunk cloud when the connection originates from an Axis or BPX midpoint.
Connection Manager GUI for preferred route displays ALL available trunks without considering the traffic class. As a result, it is possible to set a preferred route for a CBR connection traversing trunks that do not support CBR traffic.
SV+ shows the status of a connection based only on the routing segment status.
In the Connection Manager GUI, you must enter both the end points (i.e. node, shelf, slot, port) in the Add Connection window before entering any connection or midpoint parameters.
For an FRSM - ASI PVC connection, the error message "Remote SCR value out of range" generated by the remote BPX, indicates that the CIR value of the Frame Relay side is below the acceptable limit (cell rate) of the trunk between the AXIS shelf and its routing node. To correct the problem, one can increase the value of CIR. E.g., if the trunk between the AXIS shelf and the routing node is a BXM trunk, the CIR value should be at least 19.2 kbps (= 50 cell/sec).
ABR.FS connections cannot be added with default values for ATM-FR SIW connection. The 'ICR TO' value has to be changed.
Certain types of connections, such as VBR.1 or CBR, with policing parameters can't be modified by SV+ if the default was changed using the switch command line interface.
While adding three segment frame relay connections where one routing node is IGX and another is BPX, connections must be mastered on feeders connected to BPX. Attempting to master connections on feeders attached to IGX hub will generate an "Internal error" error message, and the connection will not be added.
Three segment voice and data connections can only be added when both routing nodes are IGXs.This is due to a switch software limitation.
While adding connections originating and terminating on same feeder nodes, SV+ will treat these connections as three segment connections and will add three segments (two on the same feeder node, one on the routing node) to realize this connection.
Switch software supports only ATFR and ATFST type of connections for UXM on a feeder node. SV+ does not support ATFR or ATFST for ATM to ATM connection (on Connection manager GUI select Configure->New ATM-TM connection->VBR.3) the connection type on switch CLI will show as ATFR for all 3 segments. If you select ABR.FS connection type for ATM to ATM connection (on connection manager GUI select Configure->New ATM-ATM connection->ABR.FS) the connection type on CLI will be ATFST for all 3 segments. For all other limitations of connection type supported for UXM on feeder node please refer to the switch software release notes for release 9.1.
ATM-FR connections with FR endpoint on IGX/IPX running 8.4.x switch software can not be set with channel type SIW (Service InterWorking) transparent or SIW translate. This feature is not supported by IGX/IPX running 8.4.X SWSW. The connections thus set using 9.1 Connection Manager would fail.
The default values provided by the Connection Manager GUI for the Frame Relay end point parameters Ingress/Egress ECN Threshold and DE Threshold are not the same as those provided by the connection service agent.
The Connection Manager GUI uses percentage notation for both the ECN Threshold and DE Threshold. However, the service agent MIB uses the absolute value for those MIB variables. If the defaults were used for GUI and service agent, following values would be setup for the PVC:
| Parameter | GUI Default Values | Service Agent |
|---|---|---|
Ingress ECN Threshold | 10% of Ingress VC Q Depth -> 6554 | 6553 |
Ingress DE Threshold | 50% of Ingress VC Q Depth -> 32768 | 32767 |
Egress ECN Threshold | 10% of Egress VC Q Depth -> 6554 | 6553 |
Egress DE Threshold | 50% of EGress VC Q Depth -> 32768 | 32767 |
The switch generates error message Failure validating remote endpoint description when the PVC was modified or deleted using SV+. The problem occurs when SV+ is managing a mix release network and the node mastering the PVC has an older release than the remote end, and the remote end point is in a newer card which was introduced after the older release. This is switch software limitation. The PVC can be deleted using the switch CLI.
Connection manager doesn't check for the SVC VPI/VCI partitioning range, if VPI value is ZERO and if SVC Hi VPI and Low VPI are set to ZERO on the switch. Because of this, VPI 0 can be used for provisioning. However, if you reserve only 0 for SVC range, Connection manager will not block the PVC provisioning.
When you start a stand-alone SCM, the following message is not an error message: Cannot communicate with SV+, either SV+ is not active or another GUI is running presently.
You should select a routing node for the SCM time sync node.
For a group of selected nodes from which statistics files are to be collected by a stand-alone SCM, the collection period should be set to the same value for all nodes.
If statistics files are being saved, the SCM does not purge these files even if the disk is full.
The SCM supports 3100 nodes maximum in stand-alone mode.
For "CISCO 3800" node types, the network parameter 'Time-out period' has to be 5 seconds.
Whenever you perform a create_db operation, the statshistory.stats file must be manually deleted.
In SWSW 8.5, the following rules are used when you configure peak interval through SV+. Violating these rules will cause TFTP error 22 displayed in the SCM.
The switch needs some processing time to parse the stats.enable file. Depending on the number of statistics and the number of objects this time can be very large. Currently SCM has a finite value for time-out (maximum 420 seconds) to wait for the switch response. Hence there might be cases where SCM will time-out waiting for switch to finish parsing the stats.enable file. If there are excessive time-outs, do one of the following:
1. Cut down on number of statistics enabled and be able to get the status of stats-enabling from SCM or
2. Keep the number of statistics but lose the status of stats-enabling from the SCM
You can use CLI commands such as dspstatparms, dspchstatcnf, dsptrkstatcnf, dspportstatcnf and dsplnstatcnf to make sure their desired statistics are enabled. Note that there can be occasional time-outs if a node is busy for that period of time, but this case at the best is intermittent and should go away once loading on the node stabilizes Following is the formula to calculate the time to enable statistics on the switch:
time = (stats / cnt) * delay
where
stats = (conns * stats_per_con) +
(CLNs * stats_per_cln) +
(trks * stats_per_trk) +
(ports * stats_per_port)
cnt = number of stats configured in one group before giving up CPU, a configurable parameter on the switch.
delay = a delay time between each group of stats get enabled, this is also a configurable parameter on switch.
This is captured in CR CSCdj39737.
SV+ must not be started from the OpenWindows Command Tool Window. If SV+ is started from Command Tool, the Command Tool may freeze the screen when Command Tool window's log buffer fills.
While SV+ is running, if the X server crashes for any reason, then SV+ should be stopped and restarted.
While SV+ is running, if remote display is killed without properly shutting down the SV+ Desktop, then reopening it remotely may not succeed.
The following limitations apply to VNS nodes:
The Wingz "Add Comment" option is not supported for virtual trunk and ATM connections. Wingz sometimes does not scroll up the list box properly.
It may occasionally take 2-3 minutes to display new nodes after addition of virtual trunks. This is due to the time required to setup link0 and link1 subscriptions.
If a blue trace is left behind on dragging a node on Network Topology, stop SV+ core processes and restart motif window manager or if possible reboot the system. Restart SV+ and check if blue trace is still left behind on dragging a node on network topology. If the problem does not go away by restarting motif window manager or rebooting the system there could be problem in the graphics card on the system. Stop SV+ core processes and edit /usr/users/svplus/.cshrc file and include the following statement in it:
setenv NWTOPOLOGY_LABEL_SHADOW offExecute the command:
source /usr/users/svplus/.cshrcRestart SV+ core processes.
This will disable the feature to draw the label as the node icon is being dragged on network topology map. For more detail, refer to bug # CSCdj86512.
Both NWTopology and SvOvTopology maps display the status of a routing node or a 3810 cluster node using the concept of compound status where the compounding is done by propagating the most critical status. The routing node icon on a map displays the color representing the worst case status of either the routing node or any of the feeder shelves connected to the routing node. The 3810 cluster icon similarly shows a color representing the worst case status of either the parent IGX node or any of the 3810 connected to the IGX node. The actual status of each node is displayed on the submap brought up by double-clicking on either the routing node icon or the 3810 cluster icon. The SvOvTopology map uses the different mechanism of compounding the node status by default. To display the correct node status on the SvOvTopology (also to be consistent with NWTopology map) the correct compound status propagation mechanism needs to be set. To do this, first bring up the "Map Description" dialog by clicking on Map->Maps->Describe/Modify command. Next, choose the "Propagate Most Critical" item from the selections under the "Compound Status:" label. Finally, select the "OK" button on the dialog. This setup will be saved in the HPOV database when exiting the SvOvTopology map and no further action is required until the HPOV database is cleaned up at which time this configuration must be performed again. There is no API provided by HPOV to do this configuration from the SvOvTopology application.
The default color of the background map can make it hard to see the color of the nodes and trunks on the map. At times it may be convenient to turn off the background map and have a solid grey background. To do this, first bring up the "Submap Description" window by clicking on the Map->Submap->Describe/Modify command. Now, delete the text from under the "Background Graphics" label and click on the "OK" button. This will replace the background map with a solid grey background. To replace the background map with another map, click on the "Browse" button in the "Submap Description" dialog mentioned above. This brings up a file selection dialog called the "Background Graphics" with a list of available GIF files. Select a GIF file and click on "OK" first in the "Background Graphics" dialog followed by in the "Submap Description" dialog. This will replace the background map. The background map selection will be in effect as long as the HPOV database is not cleared at which point the selection need to made again.
If the nodes are grouped in the topology, a double click on that group shows only the list of nodes in that group. It doesn't give access to any of those nodes. The list doesn't show the status of the node(s) also.
Network Browser will not come up if the color allocation fails during it's start-up, due to other active color intensive applications, like Netscape browser. However, NWBrowser process will be running in the background. So next time when you try to bring up network browser, it will not come up, since already on instance is running.
Always use the SV+ ImageDownload program to do a SW/FW download. Since SV+ does not make any assumptions on the filename, it requires you to tell the SW the filename and the path to download, avoiding any inconsistencies resulting from the file naming assumptions made by the getfwrev and loadfwrev commands. If the SV+ ImageDownload program does not work, then there is some problem with the file transfer or the image.
Voice connection G729 and G729A are not supported from connection manager and service agent
Multicast, voice and data connections are not supported though service agent.
There is no support for Equipment manager GUI for Axis 4.1. Cisco View is used for equipment management of Axis 4.1.
The basic SNMP Agent functionality is unchanged from release 8.2. ATM-ATM and ATM-FR cross connections are supported through the Connection Service Agent.The Port Service Agent will support a physical port addressing for FRSM and a logical port addressing for the rest of the cards. In the case of CESM and FRP, the logical port addressing is identical to physical port addressing. The structure of the SV+ 8.4 service MIB has been re-organized.
The SNMP master agent is configured to use 8161 as a default port id for agent communication. The configuration file SNMPAgent.conf for the master agent is located in /usr/users/svplus/config. If you are running another Network Manager which uses port number 8161, this UDP port can be configured to some other port number in this file as follows:
The Service MIB (Connection Service MIB and Port Service MIB) uses community strings for authentication. The Connection Service Agent and Port Service Agent processes use /usr/users/svplus/config/SNMPProxy.conf file as a configuration file. The SNMP community name strings can be configured in this file as follows:
The SNMP community names "public" and "private" are configured in this file for GET and SET respectively as defaults.
The telnet command in AIX 4.x(x>= 1) has the following problem. If it is used to login to any of the StrataView nodes (BPX/IPX/IGX), the login user name and password are not taken properly and the login always fails. The workaround for this is to set the 'telnet' mode to character mode. For this enter the telnet escape character (usually combination of Control key and ']' - left square bracket -keys), which is shown on the screen as soon as the telnet command is given at 'Enter User ID:' prompt. telnet > mode character <ENTER>
The telnet command in AIX 4.1 (and above) has a login problem. If used to login to any of the StrataView nodes (BPX, IPX, or IGX), the login user name and password are not received properly by the workstation and the login always fails.
The workaround for this is to set the telnet session to character mode. To set the telnet session to character mode, complete the following stops:
Step 1 Enter the telnet command to connect to the remote host.
% telnet hostname
Trying 192.10.1.2...
Connected to hostname.cisco.com
Escape character is '^]'.
login:
Step 2 Enter the escape character at the login prompt (Control and right square bracket simultaneously).
login: Ctrl ]
telnet>
Step 3 Enter the following at the telnet prompt.
telnet> mode character
Step 4 Enter the login user ID and press Return.
user_ID
Password:
Step 5 Enter the password and continue as usual.
The following changes were made in axis.mib in SV+ 9.1.08.
Changes from axis.mib release 4.0.18 to 4.0.19.
Changes from axis.mib release 4.0.19 to 4.0.20/4.1.04.
egrQCLPThreshLow, egrQEfciThresh in ausmPortCnfServiceQueGrpTable.
Support for cesChanIdleCodeIntgnPeriod object has been added. This has been done as a result of idle supression bugfix.
The following changes were made in SV+Service mib in SV+ 9.1.07.
The following changes were made in axis.mib in SV+ 9.1.07 (changes from axis.mib release 4.1.00 to 4.1.02).
The section provides a summary of changes to the SV+ database definitions with new tables and additions to existing database definition tables.
The following columns were added to the database from 9.1.06 to 9.1.07:
| Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|
min_rx_links | no | short | Minimum number of receive links required to be active for IMA group to be in the UP state |
min_tx_links | no | short | Mimimum number of transmit links required to be active for IMA group to be in the UP state |
ima_symmetry | no | short | Symmetry of IMA Group. |
This section lists tables that were not in the 8.4 and /or 9.0 releases of Cisco StrataView Plus.
VOICE_CHANNEL describes a new database table that was not in the SV+ 8.4.
| Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|
chnl_obj_id | Yes | int | Voice channel Object ID. |
l_node_id | Yes | int | Cisco SV+ node ID. |
1_slot |
| short | Slot number. |
l_line |
| short | Port number. |
l_chnl |
| short | Channel number. |
per_util |
| short | Percent utilization (0 - 100). |
cos |
| short | Class of service. |
eia |
| short | EIA rate (0 - 20). |
dfm_len |
| short | DFM length (0, 1, 7, 8, 16). |
chnl_info |
| short | Data channel info: Bit5: OCU: 0 = reset, 1 = Set Bit4: DS0A, UCS: 0 = reset, 1 = Set Bit3: DTE: 0 = DCE, 1 = DTE Bit2-1: Clocking: 0 = normal, 1 = split, 2 = looped Bit0: DFM flag: 0 = Off, 1 = On |
input_loss |
| short | Input loss. |
output_loss |
| short | Output loss. |
onhook_ab |
| short | Onhook AB: Bit4-2: Onhook B: 0 = 0, 1 = 1, 2 = don't care, 3 = unknown, 4 = not used. Bit1-0: Dial type: 0 = Inband, 1 = pulse, 2 = User Dial. |
onhook_cd |
| short | Onhook CD: Bit4-2: Onhook D: 0= 0, 1 = 1, 2 = don't care, 3 = unknown, 4 = not used. Bit1: Sig Inject. BIt0: Sig Extract. |
chnl_type |
| short | Channel type. |
cndt_crtr_indx |
| short | Conditioning criterion index. |
tx_ab_sgnl |
| short | Transmit AB signalling: Bit7-5: Tx/Rcv X signalling Bit4-2: Tx/Rcv Y signalling 0=sig. bit is 0, 1= sig. bit is 1, 2=tx sig. bit transparently, 3=don't tx sig. bit, 4=Reverse/Inverse sig. bit. Bit1=0: Spare |
tx_cd_sgnl |
| short | Transmit CD signalling. Same as tx_ab_sgnl. |
rcv_ab_sgnl |
| short | Receive AB signalling (same as tx_ab_sgnl). |
rcv_cd_sgnl |
| short | Receive CB signalling (same as tx_ab_sgnl). |
sgnl_intgr_time |
| short | Signalling integration time(ms). |
min_wink |
| int | Minimum wink (ms) (100 - 300). |
playout_delay |
| short | Playout_delay (120 - 200). |
iec |
| short | IEC parms: |
DATA_CHANNEL describes a new database table that was not in the SV+ 8.4.
| Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|
chnl_obj_id | yes | int | Data channel Object ID. |
l_node_id | yes | int | Cisco SV+ node ID. |
1_slot |
| short | Slot number. |
l_line |
| short | Line number. |
l_channel |
| short | Channel number. |
per_util |
| short | Percent utilization (0 - 100). |
cos |
| short | Class of service. |
eia |
| short | EIA rate (0 - 20). |
dfm_len |
| short | DFM length (0, 1, 7, 8, 16). |
chnl_info |
| short | Data channel info: |
../../../../../../../../home/home.htm describes a new database table that was in neither SV+ 8.4 nor SV+ 9.0.
| Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|
node_id | Yes | int | Cisco SV+ node ID. |
slot | Yes | short | Slot number. |
type | Yes | short | Protocol type: |
group | Yes | short | Group number. |
config_type |
| short | Config type: |
local_ack |
| short | Local ack flag: |
state |
| short | Operational status: |
LINK_STATION describes a new database table that was in neither SV+ 8.4 nor SV+ 9.0.
| Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|
obj_id | Yes | int | Object ID. |
node_id | Yes | int | Cisco SV+ node ID. |
slot |
| short | Slot number. |
line |
| short | Line number. |
port |
| short | Port number. |
logical_port |
| short | Logical port number. |
address |
| short | Address. |
mac_address |
| char (15) | Physical address. It is 6 bytes in hex as format "0000.0000.0000". |
max_frame |
| short | Maximum size of a frame on this station. Value is given in bytes. |
xid |
| int | XID value to be exchanged for this station. |
state |
| short | operational status: |
CHANNEL_ROUTE describes a new database table that was in neither SV+ 8.4 nor SV+ 9.0.
| Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|
obj_id | Yes | int | Object ID. |
node_id | Yes | int | Cisco SV+ node ID. |
slot |
| short | Slot number. |
line |
| short | Line number. |
port |
| short | Port number. |
logical_port |
| short | Logical port number. |
dlci |
| short | DLCI number. |
lcn |
| short | Logical channel number. |
address |
| short | Station address number (for BSTUN, it is CU address. For FRASBAN, it is route ID. For others, it is Link Station address). |
type |
| short | Route type: |
lsap |
| short | The LSAP used to differentiate between tunnels on this DLCI (for STUN/BSTUN/FRAS-BNN only). |
rsap |
| short | The RSAP used to differentiate between connections on this DLCI (for FRAS-BNN only). |
th_type |
| short | th_type (for FRASBNN only): none 1 |
bni |
| char (15) | The BNI used for this BAN addressing scheme. It is 6 bytes in hex as format "0000.0000.0000" (for FRAS-BAN only). |
state |
| short | operational status: |
STATION_DATA describes a new database table that was in neither SV+ 8.4 nor SV+ 9.0.
| Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|
timestamp | Yes | integer | Time stamp. |
l_node_id | Yes | integer | Node ID. |
stn_obj_id | Yes | integer | Station Object ID. |
stat_type | Yes | short | Statistics Type. |
bucket_type | Yes | short | Bucket interval in minutes. |
totald |
| float | Total count. |
peak |
| float | Peak count. |
This section lists new entries in the SV+ 9.1 database tables that were not in the SV+ 8.4 database tables.
| Table | Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|---|
PACKET_LINE | l_num_phy_line |
| short | Local number of physical lines: |
PACKET_LINE | r_num_phy_line |
| short | Remote number of physical lines: 1 for normal and virtual trunks having physical lines. 2 to 8 for IMA Trunks. Default value for upgrade to SV+ 9.1 is -1. |
CIRCUIT_LINE | l_port |
| short | Local-end logical port number. |
CIRCUIT_LINE | line_info |
| short | line info flag: bit2-Coding: 0=U-law, 1=A-law bit1-CAS: 0=FALSE, 1=TRUE bit0-CCS: 0=FALSE, 1=TRUE |
FRP | elmi |
| short | 1 = ELMI enabled -1 = ELMI disabled or this field is not applicable. This field was earlier used only for Axis nodes. Beginning with Cisco SV+ version 9.1, it is also used for IGX. |
FRP | subrate_speed |
| short | Port subrate speed (for FRASM only): |
FRP | interface |
| short | Port interface (for FRASM only): ds0, ds0a or ds0b. |
FRP | encoding |
| short | Port encoding: nrz or nrzi (for FRASM only). |
FRP | role |
| short | Port role: primary, secondary or negotiable (for FRASM only). |
FRP | max_frame |
| short | Maximum number of bits expected in an inbound frame (for FRASM SDLC port only). |
FRP | retry_cnt |
| short | Number of retry attempts (for FRASM SDLC and BSC port only). |
FRP | ack_wait_time |
| int | Number of milliseconds the software waits for an ack before attempting recovery (for FRASM SDLC port only). |
FRP | vmac |
| char (15) | Virtual mac address for BAN group addressing. It is 6 bytes in hex. The format is "0000.0000.0000" (for FRASM SDLC port only). |
FRP | poll_cycle |
| short | Number of 1/10 of a second intervals to wait between the start of a polling cycle (for FRASM BSC port only). |
FRP | poll_intv |
| short | Number of 1/10 second intervals between polls (for FRASM BSC port only). |
FRP | group |
| short | Protocol group number (for FRASM STUN or BSTUN port only). |
USER_CONNECTION | l_rate_type |
| short | Local rate type (for voice/data connections only): |
USER_CONNECTION | l_rate_fctr |
| short | Local rate factor (for data connections only): |
USER_CONNECTION | l_smpl_per_pckt |
| short | Local sample per packet (for data connections only). |
USER_CONNECTION | r_rate_type |
| short | Remote rate type (for voice/data connections only). |
USER_CONNECTION | r_rate_fctr |
| short | Remote rate factor (for data connections only). |
USER_CONNECTION | r_smpl_per_pckt |
| short | Remote sample per packet (for data connections only). |
USER_CONNECTION | l_cbr_clock_mode |
| short | Local end CBR clock mode - CESM. |
USER_CONNECTION | l_cas |
| short | Local end signalling pass - CESM. |
USER_CONNECTION | l_partial_fill |
| short | Local end partial fill - CESM. Value range: 0-47 |
USER_CONNECTION | l_idle_detection |
| short | Local end idle detection - CESM-8. Values: disable (1) and onhook (2). |
USER_CONNECTION | l_onhook_code |
| short | Local end onhook code - CESM-8. Values range: 0-15. |
USER_CONNECTION | l_idle_suppression |
| short | Local end idle suppression - CESM-8. |
USER_CONNECTION | r_cbr_clock_mode |
| short | Remote end CBR clock mode - CESM. |
USER_CONNECTION | r_cas |
| short | Remote end signalling pass - CESM. Values: |
USER_CONNECTION | r_partial_fill |
| short | Remote end partial fill - CESM. |
USER_CONNECTION | r_idle_detection |
| short | Remote end idle detection - CESM-8. |
USER_CONNECTION | r_onhook_code |
| short | Remote end onhook code - CESM-8. |
USER_CONNECTION | r_idle_suppression |
| short | Remote end idle suppression - CESM-8. |
USER_CONNECTION | l_mc_type |
| short | Local multicast type flag (for multicast connections). The values are normal (0), root (1) and leaf (2). |
USER_CONNECTION | r_mc_type |
| short | Remote multicast type flog (for multicast connections). |
USER_CONNECTION | l_end_nni
|
| short | -1: unknown port type. |
USER_CONNECTION | r_end_nni |
| short | -1: unknown port type. |
CONNECTION | rate_type |
| short | For voice/data connections only: |
CONNECTION | rate_fctr |
| short | For data connections only: |
CONNECTION | smpl_per_pckt |
| short | For data connections only: |
CONNECTION | retry_cnt |
| short | Number of retry attempts before declaring failure (for FRASM llc port only). |
CONNECTION | ack_wait_time |
| int | Number of millisecond intervals the implementation waits before resending unacknowledged information frames (for FRASM llc port only). |
ATM_CONNECTION | mc_type |
| short | Multicast type: |
ASI_LINE | l_trk |
| short | Logical Trunk number for trunks having physical lines. For non physical lines it is -1. Default value for upgrade to Cisco SV+ 9.1 is -1. |
ASI_LINE | l_vtrk |
| short | When trunks have physical lines and it is a virtual trunk, it contains the virtual trunk number, otherwise it is -1. Default value for upgrade to Cisco SV+ 9.1 is -1. |
ASI_LINE | l_line |
| short | Physical line number. This is unique per card. For example, when physical lines are 2, 3 for one trunk and 6, 7 for another trunk on the same card, this field is 2, 3 for the first trunk and 6, 7 for the second trunk. For non physical lines it is -1. Default value for upgrade to Cisco SV+ 9.1 is -1. |
CARD | fc_fab_num |
| char (21) | Front card FAB number. |
AUSM_PORT | ima_symmetry |
| short | Symmetry of the IMA group; not modifiable after create. Asymmetric Operation and Asymmetric Configuration are not supported. ATM Forum compliant IMA ports only. |
AUSM_PORT | min_tx_links |
| short | Minimum number of transmit links required to be active for the IMA group to be in the Up state.Eventhough the range is 1..8, this value should be <= maximum number of configured links in IMA group. ATM Forum compliant IMA ports only. |
AUSM_PORT | min_rx_links |
| short | Minimum number of receive links required to be active for the IMA group to be in the Up state.At present, since only symmetric configuration is supported, this should be equal to axisImaGroupMinNumTxLinks. ATM Forum compliant IMA ports only. |
CESM_CONNECTION | l_line |
| short | Local line number. |
CESM_CONNECTION | r_line |
| short | Remote line number. |
CESM_CONNECTION | cbr_clock_mode |
| short | Specifies clocking mode of the CBR service: |
CESM_CONNECTION | cas |
| short | Specifies when CAS bits are carried by the service. |
CESM_CONNECTION | partial_fill |
| short | Number of user octets per cell, when partial cell fill is used. |
CESM_CONNECTION | idle_detection |
| short | Idle Detection (CESM-8). |
CESM_CONNECTION | onhook_code |
| short | Onhook Code (CESM-8). |
CESM_CONNECTION | idle_suppression |
| short | Idle Suppression (CESM-8). |
CESM_CONNECTION | cbr_clock_mode |
| short | Specifies clocking mode of the CBR service: |
This section lists new entries in the SV+ 9.1 database tables that were not in the SV+ 9.0 database tables.
| Table | Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|---|
PACKET_LINE | l_num_phy_line |
| short | Local number of physical lines: |
PACKET_LINE | r_num_phy_line |
| short | Remote number of physical lines: 1 for normal and virtual trunks having physical lines. 2 to 8 for IMA Trunks. Default value for upgrade to SV+ 9.1 is -1. |
FRP | subrate_speed |
| short | Port subrate speed (for FRASM only): |
FRP | interface |
| short | Port interface (for FRASM only): ds0, ds0a or ds0b. |
FRP | encoding |
| short | Port encoding: nrz or nrzi (for FRASM only). |
FRP | role |
| short | Port role: primary, secondary or negotiable (for FRASM only). |
FRP | max_frame |
| short | Maximum number of bits expected in an inbound frame (for FRASM SDLC port only). |
FRP | retry_cnt |
| short | Number of retry attempts (for FRASM SDLC and BSC port only). |
FRP | ack_wait_time |
| int | Number of milliseconds the software waits for an ack before attempting recovery (for FRASM SDLC port only). |
FRP | vmac |
| char (15) | Virtual mac address for BAN group addressing. It is 6 bytes in hex. The format is "0000.0000.0000" (for FRASM SDLC port only). |
FRP | poll_cycle |
| short | Number of 1/10 of a second intervals to wait between the start of a polling cycle (for FRASM BSC port only). |
FRP | poll_intv |
| short | Number of 1/10 second intervals between polls (for FRASM BSC port only). |
FRP | group |
| short | Protocol group number (for FRASM STUN or BSTUN port only). |
USER_CONNECTION | l_cbr_clock_mode |
| short | Local end CBR clock mode - CESM. |
USER_CONNECTION | l_cas |
| short | Local end signalling pass - CESM. |
USER_CONNECTION | l_partial_fill |
| short | Local end partial fill - CESM. Value range: 0-47 |
USER_CONNECTION | l_idle_detection |
| short | Local end idle detection - CESM-8. Values: disable (1) and onhook (2). |
USER_CONNECTION | l_onhook_code |
| short | Local end onhook code - CESM-8. Values range: 0-15. |
USER_CONNECTION | l_idle_suppression |
| short | Local end idle suppression - CESM-8. |
USER_CONNECTION | r_cbr_clock_mode |
| short | Remote end CBR clock mode - CESM. |
USER_CONNECTION | r_cas |
| short | Remote end signalling pass - CESM. Values: |
USER_CONNECTION | r_partial_fill |
| short | Remote end partial fill - CESM. |
USER_CONNECTION | r_idle_detection |
| short | Remote end idle detection - CESM-8. |
USER_CONNECTION | r_onhook_code |
| short | Remote end onhook code - CESM-8. |
USER_CONNECTION | r_idle_suppression |
| short | Remote end idle suppression - CESM-8. |
USER_CONNECTION | l_mc_type |
| short | Local multicast type flag (for multicast connections). The values are normal (0), root (1) and leaf (2). |
USER_CONNECTION | r_mc_type |
| short | Remote multicast type flog (for multicast connections). |
USER_CONNECTION | l_end_nni
|
| short | -1: unknown port type. |
USER_CONNECTION | r_end_nni |
| short | -1: unknown port type. |
CONNECTION | retry_cnt |
| short | Number of retry attempts before declaring failure (for FRASM llc port only). |
CONNECTION | ack_wait_time |
| int | Number of millisecond intervals the implementation waits before resending unacknowledged information frames (for FRASM llc port only). |
ATM_CONNECTION | mc_type |
| short | Multicast type: |
ASI_LINE | l_trk |
| short | Logical Trunk number for trunks having physical lines. For non physical lines it is -1. Default value for upgrade to Cisco SV+ 9.1 is -1. |
ASI_LINE | l_vtrk |
| short | When trunks have physical lines and it is a virtual trunk, it contains the virtual trunk number, otherwise it is -1. Default value for upgrade to Cisco SV+ 9.1 is -1. |
ASI_LINE | l_line |
| short | Physical line number. This is unique per card. For example, when physical lines are 2, 3 for one trunk and 6, 7 for another trunk on the same card, this field is 2, 3 for the first trunk and 6, 7 for the second trunk. For non physical lines it is -1. Default value for upgrade to Cisco SV+ 9.1 is -1. |
CESM_CONNECTION | cbr_clock_mode |
| short | Specifies clocking mode of the CBR service: |
CESM_CONNECTION | cas |
| short | Specifies when CAS bits are carried by the service. |
CESM_CONNECTION | idle_detection |
| short | Idle Detection (CESM-8). |
CESM_CONNECTION | onhook_code |
| short | Onhook Code (CESM-8). |
CESM_CONNECTION | idle_suppression |
| short | Idle Suppression (CESM-8). |
CESM_CONNECTION | cbr_clock_mode |
| short | Specifies clocking mode of the CBR service: |
ACCESS_NODE | device_id |
| short | Device ID |
This section lists known anomalies and anomalies corrected in this release.
The following is the list of known anomalies in the 9.1.10 release of Cisco StrataView Plus software.
| Bug ID | Descriptions |
|---|---|
CSCdk82083 | Loop timing on CESM lines on AXIS shelf cannot be configured using Equipment Manager GUI. |
CSCdk84287 | SV+ Topology doesn't update the node status when the nodes become unreachable. |
CSCdk89647 | SV+ INSTALL fails, if there are multiple entries in /etc/hosts file with the same host name, even though they are commented. |
CSCdk58425 | If an IMA group has failed on AXIS shelf, PVCs in another group will be shown in failed state. |
CSCdm46717 | The connchk script in /usr/users/svplus/tools directory doesn't list all the incomplete connections and shows incorrect status for some of the connections. |
CSCdk58425 | If an IMA group has failed on AXIS shelf, PVCs in another group will be shown in failed state. |
CSCdk83208 | Network Browser intermittently shows nodes in sync state, though some of the cards in those node are marked as out of sync in SV+ Database card table. |
CSCdk84287 | SV+ Topology doesn't update the node status when the nodes become unreachable. |
CSCdm46717 | The connchk script in /usr/users/svplus/tools directory doesn't list all the incomplete connections and shows incorrect status for some of the connections. |
CSCdr31980 | Number of incomplete user connections increased at one of three CWMs in 9.1. |
CSCdp43612 | Intermittently, the connection manager does not see ports. The issue was with failure to get shared memory access. In a large network whenever the problem occurred, the "Failed to get shared memory" error message was displayed. |
CSCdp90026 | Added a CESM to CESM 3 segment T1 structured connection without a loopback on one of the CESMs. Connection manager showed an a-bit alarm for this connection. Placed a loopback on the CESM port and added more structured connections. The new connections were displayed with an OK status but after repeated refreshes, the original connection still showed an a-bit alarm. No alarms were present on AXIS or BPXs. Executed a test delay on the connection and it passed succesfully but connection manager changed the connection status to failed. |
CSCdr34196 | ConnProxy ABR1 MIN modify failure. A general SNMP failure occurred on the agent. |
CSCdr02040 | New Reports Traffic Summary reports trunk load > 100 %. A customer is producing reports using the new reports application and the Top Utlization reports displays trunks with Util > 100 %. The reports appear to be inaccurate. The trunk that these stats were collected from is a E3. The problem occurred when collecting statistics and producing the output using New reports. The customers database has been recreated but the problem remained. |
CSCdr26425 | New reports hangs when you run connection traffic summary report on Voice connection. Customer is running 9.1.07. I reproduced on 171.68.205.131 which is running 9.1.09 patch 7. igx28 has 3 voice connections. Lab 9.2 CWM was able to graph these same connections successfully. |
CSCdm09863 | Statsmanager GUI shows many time sync node timeouts. SCM is enhanced to try connecting to time sync host 15 times before giving up and record "failed" error. Previously, when connect to time sync host has an error, SCM recorded incorrectly a "timed out" error. |
CSCdr46338 | Statistics for "Frame Received with BECN" and "Frame Received with FECN" were enabled on StatsMgr. These items were defined as 44, 45 in StatsMgr. However, 44, 45 were defined as "44 = Unkn Prot Frms Dscd at Egress" and "45 = Cells Received from Port" in IGX. |
CSCdr45344 | CWM allows a frame relay connection on a UFM-U card with CIR, MIR, PIR, QIR of virtually any speed, even 5000 on a v.35 port of 256kbps. The same, when tried from the CLI of the IGX card, gives an error message saying "MIR exceeds peak". It also allows a PCR value of 5000 cps on the ATM side simultaneously. This is true when modifying the connections too. |
CSCdr54592 | Some problems happened when executed unGroup command. Please add in unGroup tools: -dncon/upcon about each connection. Please fix for LONG HOP COUNT Routes. Customer is using Group Connection and current SWSW Release is 8.4.21. They will soon upgrade to 9.1.xx, but SWSW 9.1 does not support 'Group Connection'. They must therefore ungroup for their connection before upgrading. Customer had executed 'unGroup' command. Then, They had experienced two problems: (1) A-Bit=0 happened about some connections on remote AXIS (by dspchstats), and (2) Preferred Route had not been set as to the connection that HOP count was high. |
The following anomalies have been corrected with the 9.1.10 version of Cisco StrataView Plus.
| BugID | Description |
|---|---|
CSCdr43788 | Disabled or an expired time-limited version of XR/table. When customer opens Equipment Manager, the error message This application is built with a XR/table is displayed. Workaround: An installation and update was performed their 9.1.09 release with the latest patch # 7. |
CSCdp62721 | Support for Audible Alarms has been reintroduced in release 9.1.09 but audible alarm does not work. Workaround: Support for Audible Alarms has been reintroduced in release 9.1.09. |
CSCdm88329 | Unable to add HI_PRIORITY or VBR-RT connections using CMGUI. Added DAX connection between VHS cards (FR-FR connection, same card -2 ports) using CMGUI, only VBR-NRT ,ABR and UBR are highlighted and VBR-rt and HI_PRIORITY are disabled. If VBR-rt or HI_PRIORITY is selected as service type, automatically the sevice type changes to VBR-nrt while adding connections. Workaround:From CLI, both VBR-rt and Hi_Priority type of connections can be added and same was displayed properly in CMGUI. |
CSCdm91369 | cmgrd does not understand node release 9.2.3.as realtime connection capable node. Therefore we cannot add real-time VBR,UBR connections on nmsigx38. Workaround: None. |
CSCdm91654 | BXM-FRSM ATM_FR atfst connection is shown as ATM-ATM in Conn-Mgr GUI. Workaround: None. |
CSCdp01303 | When customer uses Connection Manager to view/modify data/voice connections, SV+ complains of an internal error and does not allow customer to view connection information. Customer is using non-standard (not public/private) community strings. Workaround. Connection Manager is attempting to contact switches using public community string, even though svplus.conf and watchdog.conf have been modified. |
CSCdj93910 | Cannot add/mod ATM ABR1 OC3 cons w/MCR=353208 (max) using ConnProxy. Workaround: Successfully added/modified using CLI. |
CSCdm95379 | .Some ATM-FR invisible when selecting only ATM-FR. New ATM-FR connection did appear in the list until click apply (Note: This will occur if selecting only ATM-FR.) Workaround. None. |
CSCdr25930 | Connection added through GUI shows Fail on CLI (Non-DAX). Workaround: Use the new default values from the MIB. |
CSCdm86541 | Frame Relay connection details are not being updated into the StrataView Plus database correctly, some are missing and some are incomplete. Workaround: After code start on SV+, added a connection to force updates to SV+ from SWSW. SV+ reported that the verification on SWSW data base looks fine. |
CSCdr03982 | Installation script cannot handle disk partition with name of nine characters. Workaround: Limit naming to eight characters. |
CSCdk36752 | .In some circumstances, the SV+ (manual) install script hangs in ilog_cleanup. Workaround: comment out SV+ Install script to not run ilog_cleanup. |
CSCdp16178 | Number of Buffers setup for Informix takes up all memory. Workaround: None. |
CSCdp16182 | If the Informix directory not removed before upgrade, Informix 72 is not installed properly. Workaround: None. |
CSCdp16184 | 9.1.09 upgrade from 9.1.06 waits for data when it should not. Also snmp.conf.orig not copied to snmp.conf. Workaround: None. |
CSCdm92999 | The traps seen in HPOV are in extended form and not per functional specification. Workaround: None. |
CSCdp72969 | SV+ dumped core when adding an ins object into the HPOV map. Workaround: Reason was user did not have all HPOV patches installed. Install all HPOV patches. |
CSCdk89004 | ConnProxy CESM 8T1C - CESM 8T1C addition fails. Workaround: The root cause is that ConnProxy has a bad default value for MaxBufSize for CESM 8T1 structured port. |
CSCdp27322 | ConnProxy coredumped. Workaround: The coredump was caused because the makefile in /src/agent/cmpa/src.Patch3 was pointing to old cmgrd/ilog/ but should have been pointing to new cmgrd.patch3/ilog. Mismatch of Ausmparams structure in cmui.h that caused the core dump. Build in /src/agent/cmpa/src.Patch3 by correcting the makefile to point to /cmgrd.patch3/ilog. |
CSCdk13201 | 97r1 compiler warnings. Workaround: Fixed in 11.3AA build. |
CSCm83613 | SNMP mods of PVCs thru ServiceMib forces %UTIL to %100. Workaround: Fixed the Problem in Rel 9.2.x.Files Changed: 1) src/agent/cmpa/src/frTable.c 2) src/agent/cmpa/src/frConnection. |
CSCdm92944 | Error message display year 2000 in wrong format. Workaround: Fixed the Problem in ConnProxy for Rel 9.1.x. |
CSCdp04800 | ConnProxy return CDVT(0+1) out of range incorrectly. Workaround: Could not reproduce the problem . The Max limit for CDVT0 5000000. |
CSCdp90676 | Modify connections failed thru proxy when atmEndPointICR was set. The GUI modification went thru fine. Note that in GUI ICR field was not modifiable. GUI took whatever value was set in the PCR field. Workaround: Do this check on done on the connproxy side, or Service MIB may be modified to say that this field is not modifiable. |
CSCdm91232 | If Narrowband Trunks were deleted and added, Narrowband Trunk ID changed on SV+ 'Reports' function. To be matched Logical Trunk No. is very difficult with physical Trunk No. Workaround: New Reports function has displayed correctly. |
CSCdp01973 | New Reports inaccurate for Top Utilization reports for trunks. Workaround: None. |
CSCdp01986 | New Reports graph for trunk traffic summary shows incorrect with E1/32 and SR/16 trunks. Workaround: None. |
CSCdp02074 | New Reports complains that start time must be before end time. Workaround: None. |
CSCdm88576 | SCM is not sending the correct enablelist to the nodes. Workaround: Manually tftp the latest enabled stat list of each node to the particular node affected and were able to collect stats. Do not use the GUI's Send Enabed stats button to avoid disabling of the parms. |
CSCdp09814 | SCM closes intermittantly. Workaround: Only one instance of SCM can be run at the same machine. |
CSCdj81162 | NW Topology does not display any Access Devices attached to feeder nodes. Workaround: Now these features have been implemented on both NWTopology as well as SvOvTopology. |
CSCdp09082 | NWTopology core dumping. Workaround: If you remove the config files under the NWTopology directory the system will function correctly. |
CSCdp38552 | llvTransformer erros when starting topology. Workaround: This bug was due to resizing the overview window below a certain size. The fix has been put such that user is not allowed to resize the window below a certain size. |
CSCdp16956 | No trap when AXIS goes unreachable. Workaround: CWM displays the event log messages received from the SW as they are in the HP OV event browser. When an AXIS node becomes unreachable,CWM gets Comm Failure from the Switch.These messages are converted into SNMP traps & sent to trap process of HPOV,which shows these traps in the event browser.CWM is transparent as far as these event log messages are concerned. |
CSCdp75366 | unGroup -c does not work with BCC-3-32/BCC-3-64/BCC-4. When using unGroup -c in BCC-3, the following error message is displayed: Ram size out of range: -1. Error getting processor card RAM size from switch. Workaround: None. |
The following anomalies have been corrected with the 2.0.00 release of WANCV which is distributed along with 9.1.10 version of StrataView Plus.
| Bug ID | Descriptions |
|---|---|
CSCdm46308 | The backcard display is 15PX and the interface line type is v35 , hence the display do not match |
CSCdm38256 | For MGX88.pkg versions earlier than 2.02, information about cards in the standby state may be displayed incorrectly for SRM modules in slots 31 or 32. The information displayed is for the SRM in the active state, if one is present in adjacent slot. |
CSCdk00065 | HPOV grapher malfunctions in CisvoView. This problem has been fixed in Cisco View engine as part of fix for anomaly CSCdk76858. |
CSCdk05434 | Display problems with Port/Channel monitor. Some MIB variables were defined as INTEGER instead of Counter in axis.my. This caused the CiscoView monitoring dialogs to display them as numbers instead of the normal counter display. A large number of variables was redefined as Counter instead of INTEGER in axis.my. This defect has been fixed in AXIS.pkg version 1.03. |
CSCdm06256 | Cisco View, rear view for IGX shows wrong card layout for UXM card. |
CSCdk07747 | BNM-155 line color changes do not function in CiscoView. Status monitoring for BNMs has been fixed in AXIS.pkg version 1.03. |
CSCdk17076 CSCdk10759 | Cisco View reports false error message while deleting a port from FRSM-8E1 card. |
CSCdk20837 | Intermittently, when changing from rear to front chassis view or vice-versa the chassis view shows up as a mix of the front and rear views. |
CSCdk21358 | Front view of a BPX in CiscoView don't get refreshed if back cards are removed first. This problem has been fixed in IGX 9.1 switch software. |
CSCdk21445 | Cisco View retrieves random number of Cards/Ports/Channels from respective table upon query. This problem was observed, when large number pots and channels are configured on FRSM-8 card. |
CSCdk51704 CSCdk18768 | Reconfiguration attempts of resource partition on CESM-8E1 card fail intermittently. This happens if there are more than 1 service module in the shelf. |
CSCdk57700 | When using Ciscoview to configure a port on an SRM3T3 card on an AXIS shelf there is no option to configure the line type to dsx3M23. |
CSCdk91145 | Cisco View front view for BPX doesn't light FAIL LED, even though the card in failed state. |
CSCdm14151 | The label for frLportPortSpeed was enhanced to clearly show the units of 100s of bits per second. |
The following anomalies have been corrected with the 9.1.09 version patch level 1 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdp09761 | BXM - FRM one segment connection other end parameters are not set properly. |
The following anomalies have been corrected with the 9.1.09 version patch level 2of Strata View Plus.
| BugID | Description |
|---|---|
CSCdp10497 | Cannot select the service type of ATFST in the Connection Manager. |
CSCdp01303 | Connection Mgr uses incorrect community strings when contacting switches. |
The following anomalies have been corrected with the 9.1.09 version patch level 3 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdm91654 | BXM-FRSM ATM_FR atfst connection is shown as ATM-ATM in Conn-Mgr GUI. |
CSCdj93910 | Cannot add or modify ATM ABR1 OC3 cons w/MCR=353208 (max) using ConnProxy |
CSCdm95379 | Some ATM-FR connections invisible when selecting only ATM-FR from ConnMgr. |
CSCdj93904 | ConnProxy should not allow atmEndptCCDV for IPX->BPX atf/atfst connections |
CSCdj93905 | Inconsistencies for atmEndptCBS between switch,mib,ConnProxy & CMGUI. |
CSCdp16178 | Number of Buffers setup for INFORMIX hog all memory. |
CSCdp16182 | When upgrading from 9.0/8.4 informix not installed properly |
CSCdp16184 | Upgrade to 9.1.09 from 9.1.06 not working (waits for data when it should not). |
CSCdk13201 | ConnProxy does invalid range checking for MinAdjustPeriod for BXM endpts. |
CSCdm83613 | SNMP modification of PVCs thru ServiceMib forces %UTIL to %100 |
CSCdm92944 | Error message displays year 2000 in wrong format |
CSCdp04800 | ConnProxy return CDVT(0+1) out of range incorrectly |
CSCdm91232 | If executing addtrk and deltrk, Narrowband TRUNK ID will change on SV+ Reports function |
CSCdp01973 | New Reports inaccurate for Top Utilization reports for trunks |
CSCdp01986 | New Reports Trunk traffic summary is comparing bytes transmitted to peak byte received |
CSCdp02074 | New Reports complain that start time must be before end time. |
CSCdm88576 | SCM is not sending the correct enablelist to the nodes |
CSCdp09814 | SCM closes intermittantly |
CSCdj81162 | Network Topology does not display any Access Devices attached to feeder nodes |
CSCdp09082 | Network Topology core dumping |
CSCdm93003 | Network Topology, map takes too long to update when Fastpad devices are deleted. |
CSCdp16956 | Axis shelf went unreachable with no traps captured in the svplus. |
CSCdp09761 | BXM - FRM one segment connection other end parameters are not set properly. |
CSCdp11459 | Connection addition between ASI & FRSM fails with error wrong Policing. |
CSCdp00125 | SV+ NWTopology process causes core dump. |
The following anomalies have been corrected with the 9.1.09 version patch level 4 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdp38552 | llvTransformer errors when starting topology. |
The following anomalies have been corrected with the 9.1.09 version patch level 5 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdp49596 | ECN Threshold shows up as zero in one segment BXM-FRM connection |
The following anomalies have been corrected with the 9.1.09 version patch level 6 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdp89024 | ECN Threshold mapping not correct for one segment BXM-FRM connection. |
The following anomalies have been corrected with the 9.1.09 version patch level 7 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdp62721 | On SV+ 9.1.09 AIX don't support audible alarm for all major alarms as in 8.4.10. |
CSCdp31386 | Audible alarm does not work. |
CSCdm39409 | StrataView+ 9.1.06 no longer supports Audible Alarms. |
The following anomalies have been corrected with the 9.1.09 version patch level 8 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdm76586 | network_id field in line table is incorrect. |
CSCdp60172 | Bad usage of tm_year, inappropriate date in error messages. |
CSCdm72969 | SV+ dumps core while trying to add a new object of type INS through HP OV. |
The following anomalies have been corrected with the 9.1.09 version patch level 10 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdr54592 | Some problems happened when executed unGroup command. |
The following anomalies have been corrected with the 9.1.09 version patch level 11 of Strata View Plus.
| BugID | Description |
|---|---|
CSCdr70644 | Some problems happened when executed unGroup Command. |
The following anomalies have been corrected in the 9.1.09 version of Strataview Plus.
| BugID | Description |
|---|---|
CSCdm43968 | Equipment manager msg:"Unable to invoke equip. management. CV is not installed or not integrated" |
CSCdm50556 | All traps received from BPX/IGX shows SV+ station as source rather than BPX name. |
CSCdm56837 | Some AXIS nodes may not get synced up (when CWM is brought up) and stay in init state. Workaround: Warm start CWM |
CSCdm38338 | Unable to add 3-segment connection from PRM to PXM-UNI. Unable to select port at PXM-UNI end. |
CSCdm59711 | When SV+ is warm started, PVCs involving AXIS may show spurious 'ABIT' condition. This could happened AUSM/FRM cards. Workaround: Coldstart SV+. |
CSCdm48074 | When doing CE-CE Connection additions trying set value for IdleCodeIntegration Period will result in an Error. There are lots of Conditions /Constraints before this variable could be set. Hence the rejection from switch. Workaround: Use default parameter or don't sent this specific value. |
CSCdm65437 | Attempts to add connections fail with subtypes atfst, atftfst and atfxfst. |
CSCdm55748 | No objects displayed for Connection->FrameRelay or ServiceLines->T1 for stats reports and util_ext: db fetch 0 shows up on the screen. |
CSCdm36901 | Various L1 errors appear in svplusL1.log |
CSCdm05854 | SV+ reports GUI, doesn't show RcvFramesUnknownProtocols stat object. This problem has been fixed in SV+ Wingz interface utility. |
CSCdm12801 | SV+ Connection Manager GUI doesn't allow the user to set partial fill value for connections on unstructured CESM 8T1/E1 ports. However, it complains that the partial fill value is not greater than 47. This problem has been fixed in Connection Manger GUI. |
CSCdm19166 | SV_CreateDB, intermittently shows some error message saying that "/usr/users/svplus/emsc*.msgs: No such file or directory." This problem has been fixed in SV+CreateDB process. |
CSCdm24894 | ALM trunks do not appear in the New Reports -> Performance Data -> Trunks -> Trunk Traffic Summary. This has been fixed in NewReports. |
CSCdm26653 | SV+ INSTALL procedure applies the patches to HP OpenView, without checking whether they are already installed or not. Because of this SV+ would overwrite some of the latest patches of HP OpenView. This problem has been fixed in SV+ install process. |
CSCdm29796 | SV+ Connection Service Agent doesn't do the valid range checking for ceEndPointMaxBufsize MIB object, while setting up the connections. This problem has been fixed in ConnProxy process. |
CSCdm30550 | While modifying a CESM 8E1 channelized connection with CDVRxT value 32000 using Connection Manager GUI, the GUI reports an error message "CeMaxBufSize should be between 5120 to 4170". However, the connection modification still fails, even after setting the CeMaxBuffSize to a value within the suggested range. This problem has been fixed in Connection Manager GUI process. |
CSCdm33287 | An intermittent DB inconsistency problem, which wrongly sets the A-bit status of ATM connections in atm_connection table to FAIL has been fixed. |
CSCdm34273 | When a user is logs on remotely, to SV+ station as svplus user, an error message 'xrdb: Can't open display' is shown. This problem happens because the environment variable DISPLAY hasn't been set. SV+ environment setup files (.cshrc etc.) have been updated to set the DISPLAY variable to either the SV+ system or to the machine from the user has logged in. If you do a remote login to launch SV+.The number of remote logins should be restricted to 1. Secondly, you should set the font size of the DISPLAY using the Style ManagerTool available in CDE. It should have a size of Small(3) or less. |
CSCdm35603 | When CiscoView is selected from Equipment Manager button of SV+ Desktop to manage BPX/IPX/IGX device running 8.4 or 8.5 release, it aborts with a error message 'selected node runs 8.x. Equipment Manager only supported for 9.1 onwards'. This problem has been fixed in Desktop process. |
CSCdm39407 | SV+ Connection Manager daemon gives VPI/VCI collision error messages during FR-CE, ATM-CE connection provisioning. The problem has been fixed in databroker process by adding the code to check for presence of colliding VPCONS while adding VCCONS. |
CSCdm41998 | SV+ Connection Manager doesn't do range checking on the CIR value against portspeed for PVCs on FRSM-8 card. This problem has been fixed in cmgrd process. |
CSCdm44647 | SV+ New Reports shows 'No Trunks found' when all trunks are selected in trunk traffic summary report. The trunk report is shown properly for each individual trunk if only one trunk is selected. |
CSCdm47446 | SV+ Connection Proxy fails with the SNMP error "Idle Code Integration Period Cannot be set if idle detection is not Enable_OnHook" error when an attempt is to made to modify a CE-CE connection without supplying CesmIdleCodeIntegrationPeriod. This problem has been fixed in ConnProxy process. |
CSCdm47461 | SV+ Connection Proxy fails to add CE-CE connection with an error message MaxBufSize is out of range. |
CSCdm48173 | SV+ Connection Proxy agent gives a general error, when an attempt is made to do snmpwalk on svConnTable in a network with CESM connections. This problem has been fixed in ConnProxy process. |
CSCdm03119 | If the SV+ Service Mib object atmEndPointMinAdjustPeriod is set to < 20 for a ATM endpoint on BXM/UXM card, SV+ Connection Service Agent considers it as invalid value and rejects the request. The valid range for this atmEndPointMinAdjustPeriod mib object in SV+ Service Mib is corrected to the following . ASI/BNI T3/E3: 20-250 msec . BXM/UXM: 3-255 msec . ABR.1: 1-100 msec The range is applicable to ABR.1 and ABR.FS connections when VSVD is enabled. |
CSCdm55596 | asi_line table does not have uxm_lines. |
CSCdm56383 | SV+ 9.1.07 connection manager fails to find AUSM port of AXIS shelf. |
CSCdm63914 | If running switch software 8.2.56, the line_load, interface, card_type from packet_line all come back as zero. Workaround: Upgrade switch software. |
CSCdm65332 | Netview does not display major/critical alarms in RED. |
CSCdm69328 | Link0 and Link1 do not always come up after reboot. |
CSCdm57341 | Setting UPC Param for Ausm_BXM or BXM_BXM Connections resulted in Connection Failure. |
CSCdm34088 | Display and updating of the "Objects Available" window in Wingz2. is slow. |
CSCdm68237 | Error message "Invalid Object Type Count in Enable List. 011" is returned when sending stats enable to a BPX node running 9.1.x and enabling some objects available under Service Interfaces --> Physical line T3/E3/OC3 sub-categories. Workaround: Disable the Physical Line T3/E3/OC3 objects causing this error before sending stat enable to the BPX node. |
CSCdk72512 | The following set of actions will cause the dialog box to appear Step 1 Double-click on a trunk icon only Step 2 Trunk listing window appears Step 3 Do not close this trunk listing window. Click somewhere in the topology window. Step 4 Click in a grey area of the trunk listing window (which will be behind the topology window). Do not click on a trunk listing row, just the grey area below it. In the above situations, a dialog box appears stating "Trunk has been deleted". |
CSCdm71424 | Upgrade from 9.1.06.SOL to 9.1.09E is dropping the database. |
CSCdj94046 | During upgrade of SV Plus, the following message occurs: "ipc.c:606:IPC Connect Failed, Address(9002) PID(862):: Connection refused" |
CSCdm82112 | Cannot see trunks on submap. This problem occurred intermittently. |
CSCdm85965 | After Backup, ANI connection selected and Add or Delete button becomes sensitive, if another ANI is selected the button remains sensitive. |
CSCdm59720 | When the % Utilization parameter is changed on an AXIS PVC, SV+ connection manager does not update the display. |
CSCdm63582 | User is unable to use the save configuration tool to get the ASC configuration saved. Items being saved are only Service Modules and not the ASC. |
CSCdm58376 | Install Script says "Welcome to Online help installation of SV+" This is misleading and is removed from the install script. |
CSCdm83480 | SV+Service.mib is not updated for UPC parameters. UPC parameters do not reflect anything for BXM or AUSM-AUSM |
CSCdm89055 | Cannot Modify BXM-FRSM and BXM-BXM atfst connections |
CSCdm88377 | Connection Manager does not set remote-end upd parameters BXM-BXM atfst connections. |
CSCdm89514 | While adding connection when AUSM is one end. Connection addition fails with an error from axis saying "wrong CLPTagFlag value" |
CSCdm91654 | BXM-FRSM ATMFRatfst connection shown as ATM-ATM in conngui. |
CSCdm06466 | The user is able to add CE connection on a port in use on AXIS nodes. The connection get refused by the switch and then backed off by the CWM. |
CSCdm85947 | NWTopology Core dumps after running for a long time. |
CSCdm87458 | SV+Service.mib needs explanations added. ATFRneeds to be defined. All Variables "atmEndpt*" are not there in service MIB, they are copied from strata.mib. Proper mapping of all the variables is required. ABR.V and ABR.nV needs some more explanation from SV+Service.mib point of view. |
CSCdm84769 | SV+ core dumps while trying to add a new object of type INS through HP OV |
CSCdm92944 | Error message display year 2000 in wrong format |
CSCdm89026 | SV+Service.mib does not say that VSVD is not modifiable |
CSCdm91232 | Narrowband Trunk ID is displayed incorrectly in "Object Available" field on SV+ 9.1.xx. If TRUNKs were deleted and added, TRUNK No. changed on 'Reports' function. 'Logical TRUNK No.' is displayed. |
CSCdm88576 | SCM is not sending the correct enablelist to the nodes |
CSCdm89040 | DBSchema document does not explain different values of VSVD. According to SV+Service.mib, vsvd=1 means enable and vsvd=2 means disable, but when a connection is added from cmgui or conn-proxy with vsvd enable, database shows vsvd=2. |
CSCdm59074 | IMA trunk failures are not highlighted on the SV+ topology map when 'Retained Links' is enabled |
CSCdk82202 | Printed topology map shows deselected background |
CSCdm83466 | EMC coredumps when emc gets tftp timeout and tries to send a cancellation request to tftpd. |
CSCdm06466 | When a connection already exists on a port on axis node, the CWM let the user create another connection. This connection gets rejected by the switch software. Upon rejection, CWM backs off the connection from the database. |
CSCdm88839 | Major/Critical alarms are not displayed on the StrataCom map within Netview. |
The following is the list of known anomalies in the 9.1.07 release of Cisco StrataView Plus software.
| Bug ID | Descriptions |
|---|---|
CSCdk88933 | SV+ topology beeps whenever user double clicks on grouped icon or group trunk icon. This happens only when the NUMLOCK or CAPLOCK is set on the keyboard. Workaround: Ensure NUMLOCK or CAPLOCK is not set. |
CSCdk90900 | The UXM card on an IGX goes into alarm and resets if the connection was added using switch CLI and then modified using the Connection Manager GUI. The work-around is to add connection using the Connection Manager GUI and modify it using the switch CLI. |
The following anomalies have been corrected with the 9.1.07 version of StrataView Plus.
| Bug ID | Descriptions | ||||||
|---|---|---|---|---|---|---|---|
CSCdj47891 | SV+ Statistics Manager GUI takes lot of time during its start-up to its initialization, before giving control to user. This is more evident in large network environments. During start-up SCM does SNMP GET operation synchronously on all the nodes to get their configured statsmaster. This adds up to it takes for the initialization. This problem has been fixed in statsmain process by making these SNMP operation asynchronous | ||||||
CSCdj68372 | Stat types "Packets Received" and "Receive Packets Discarded" are missing in Data Connection section of Statistics Collection Manager. These statistic types have been added Statistics Collection Manager and the reports tool. | ||||||
CSCdj69487 | SV+ Connection Proxy agent fails to modify preferred route of a CESM connection. This problem has been fixed in ConnProxy process. | ||||||
CSCdj77506 | The currentRoute of a PVC is shown as NULL after test delay operation done using SV+ SNMP agent. This problem has been fixed in ConnProxy process. | ||||||
CSCdj81530: | Connection Proxy and Connection Management GUI can't setup ATM connections if the VPI value given is in the range of 256-4096 for connections involving BXM/ASI NNI port. It has been fixed to take the values for atmEndPointVpi in the range of 0 to 4095 for BXM/ASI NNI port. For UNI port the range is 0-255.For AUSM NNI VPI range is 0-255. | ||||||
CSCdj88008 | The following non-interval IGX statistics for the UXM have been removed from statsenablelist.stats file. ASI Connection 0 7 300 Average Cell Rx Q Depth 2 51 91 Average Cell Tx Q Depth 2 59 91 Egress VSVD Allowed Cell Rate 2 58 91 Ingress VSVD Allowed Cell Rate 2 57 91 ASI Port 3 1 300 Last known VPI/VCI 2 37 91 | ||||||
CSCdk02155 | Information traps are not handled properly by SV+. SV+Network.mib (to include info enum value) and emsc process have been updated to fix this problem. | ||||||
CSCdk02834 | Frame Forward and FUNI enum are missing from SV+ Service mib for frEndPointchanType mib object. Enumerations frFUNI(4), frForward(5) have been added to this mib variable. Defaults for this attribute: FUNI ports: frFUNI FF ports : frForward Other : frNIW frFUNI is applicable for FUNI ports only. frForward is applicable for FrameForwarding ports only. | ||||||
CSCdk04116 | Database inconsistency between two SV+ stations managing same network, after the cold start (after creating SV+ DB) has been fixed in SV+CreateDB process. | ||||||
CSCdk04123 | Error window in SCM has been made scrollable. | ||||||
CSCdk04921 | Local DLCI field in DB gets populated with -1 values for voice and data connections. This has been fixed in emsc process. l_dlci is not applicable to voice and data connections. Now the new value being set is 1. | ||||||
CSCdk12929 | StrataView Plus Connection Manager GUI only allows the range 1..24,000 cells for the parameter MBS of the BXM cards. BXM cards support the range 1..5,000,000 cells for MBS. This problem has been fixed Connection Manager GUI process. | ||||||
CSCdk16795 | An intermittent problem in topod process, because of which some of the AXIS nodes are wrongly shown as unreachable in NWBrowser has been fixed. This problem occurs when an AXIS node has no alarm or connection problem with its routing node. During SV+ cold start, these nodes are mistakenly reported as alarm status 'clear', but mgmt_state 'unreachable'. | ||||||
CSCdk21838 | Communication break alarms 20016 and 20017 are not getting generated, instead 20006 and 20007 get generated. The trap numbers were changed in 9.1, the correct trap numbers are 20016 and 20017. | ||||||
CSCdk23119 | The default value shown for chanType in Connection Manager GUI is SIW for ATM-FR new connection window. But SIW is not supported for FR cards on switch feeders IPX/IGX. This problem has been fixed in Connection Manager GUI process. | ||||||
CSCdk24081 | If axis is in minor alarm and for any reason a feeder alarm for that axis is generated, there is no corresponding clear feeder alarm getting generated when the feeder alarm is cleared. This bug has been fixed in emsc process. | ||||||
CSCdk25132 | SV+ install fails if the target disk/slice has more than one digit. That is, if the disk that the raw-partition is being installed on has tNN, where NN is the target, the install script will fail as in the following example: /dev/dsk/c0t15d0s5. This problem has been fixed in SV+ INSTALL process. | ||||||
CSCdk32996 | A database inconsistency issue, where ipx_netw_id field in network table is always populated as -1, has been fixed in topod process. | ||||||
CSCdk34622 | Values for the column protocol_type in SV+ database table - frp for certain rows, do not match with the enumerations specified in the SV+ Database Interface Manual. This happens for protocol types - none and LMI with Async Updates. This has been fixed by update SV+ Database Interface Manual.' | ||||||
CSCdk35335 | SV+ SNMP Agent gets the VSVD as disabled even if VSVD is enabled on a connection. This problem has been fixed in ConnProxy process. | ||||||
CSCdk37713 | SV+ install overrides root users PATH environment variable. This has been fixed in SV+ install procedure. | ||||||
CSCdk37805 | When EMGUI is iconified and EM desktop button is pressed EMGUI does not deiconifed. This problem has been fixed in Equipment Manager GUI process. | ||||||
CSCdk38099 | The switch generated error messages shown on the CM GUI result window sometimes are vague to indicate the true problem. This occurs when SV+ release 9.1 is used to provision pre 8.5 IPX/IGX frame relay PVC with channel type option as SIW-Translate or SIW-Transparent. The SIW-Translate and SIW-Transparent channel types are not supported by the IPX/IGX switch until 8.5 release. This is a switch limitation which prohibits the creation of such PVC. No true workaround exists for pre 8.5 switch software. If SIW-Translate or SIW-Transparent feature is needed, upgrading switch software is the only solution. The enhancement implemented on the SV+ side is to generate a more user friendly message to point out the feature is not supported by the switch running pre 8.5 switch software. | ||||||
CSCdk38581 | SV+ system log shows error message, even the peak value given in SCM wholly divides the collection interval and bucket interval. This has been fixed in statsmain process. | ||||||
CSCdk39653 | A DB inconsistency issue related to voice and data connection in user_connection and connection tables has been fixed. This problem has been fixed in emsc process. Because of this problem, when voice and data connection are added, DB doesn't get properly updated. | ||||||
CSCdk42137 | SV+ Service Agent will fail on adding a new CESM port that spans time slot 16, if the line is configured for CAS. This happens only when a port is added on CESM E1 card, when line is configured for CAS. As a work-around, skip timeslot 17 in the bit map, while using Proxy Agent to do port creation with such configuration. Further problem description: When adding a new CESM port that spans timeslot 16, the proxy will fail if the line is configured for CAS. This operation is successful when adding the port from the command line. On CESM, when an E1 line is in CAS or CAS_CRC mode timeslot 17 is allocated for signalling and can't be used for port creation. Using CLI to create a port spans timeslot 17, agent will automatically skip the timeslot. This can be verified by the timeslot bitmap in dspport. When using Proxy Agent to do port creation with such configuration, you have to skip timeslot 17 in the bitmap. | ||||||
CSCdk42244 | LMI setting won't change on FRSM-HS1 card in Equipment Manager GUI. When adding a new port on FRSM-HS1 with LMI protocol other than "No signalling," or modifying the LMI setting, Equipment Manager GUI will return back to the original setting when it prompts "Completed." Further Problem Description: 1. When adding a port on a FRSM-HS1 card, if select protocol type other than "No signalling" in LMI parameter field, the result box will print "Wrong Value", and all setting in LMI parameter field return back to No signalling. Go back to the port selection window and hit Apply button again shows that the port was added and the LMI parameters were set correctly. 2. When modifying a port on a FRSM-HS1 card, after apply the change the result window shows Completed but the LMI parameter field go back to "No signalling" (the default setting). Re-select the port for modification shows that the port parameters did not get changed. | ||||||
CSCdk42752 | A problem in topod process, where it doesn't populate its internal node cache with SV+ gateway field has been fixed. The SV+ gateway field is the key to link0/link1 IP reachability trap generation. Without the clear indication whether a node is SV+ gateway, the current link0/link1 IP reachability capability would generate traps twice for the SV+ gateway node. | ||||||
CSCdk42768 | A functional inconsistency in Network Browser process in reporting state of AXIS nodes and state of routing nodes has been fixed. | ||||||
CSCdk43249 | bc (back card) value is not updated properly in connection table when creating a FR-FR connection using Connection Manager. A wrong value of 65535 is stored always. | ||||||
CSCdk44179 | Slot dialog in Connection Manager shows slot 0 when selecting Voice and Data slots on an IPX node. This problem occurs when using SV+ 9.1 to manage 8.4 IPX node. This problem has been fixed in emsc process. | ||||||
CSCdk44435 | SV+ Connection Manager does not allow the "Signalling pass through" option be changeable during pvc addition on CESM structured port. The problem only occurs when the CESM structured port speed is greater than 64Kbps (more than 1 T1/E1 timeslot). There is no work-around to this problem, other than changing the option from AXIS CLI. Further Problem Description: The "Signalling pass through" option is applicable for any CESM structured port no matter the structured port included only one or more than one timeslots. | ||||||
CSCdk45518 | After a FRP port is deleted, it takes sometimes before it can be added back, even though SNMP get on the port confirms that the port is deleted. The wait is usually more than 30 seconds. This has been fixed in ConnProxy process. Further problem description: This is a timing issue. After the port is deleted, if an attempt to add back that port is done immediately, ConnProxy may not allow you to do so. The reason is ConnProxy goes to the DB to check for port existence. And if it happens that the robust message has not come from the network to update the FRP table, ConnProxy thinks the port still exists and hence reject the add operation. The fix is to remove the DB port existence check, and forward the add request to the switch to let it determine if the port exists or not. | ||||||
CSCdk45650 | PVC Failed trap 25011 sent when AXIS switch to secondary FRSM card and the PVC is shown in failed state. This happens when secondary FRSM-8 card takes over from primary FRSM-8 card in a redundant card setup in AXIS shelf. Further Problem Description: When switch from a primary FRSM-8 card to a secondary FRSM-8 card on an AXIS shelf, a PVC failed trap is sent from SV+ and on Connection Manager the connection will be in Failed state and later on back to clear state. In OpenView/NetView trap log, you will see User Connection Failed followed by User Connection Clear traps. | ||||||
CSCdk46980 | The MIB definitions for svConnAlarmLocalEndNNI and svConnAlarmRemoteEndNNI do not correspond to the OID values being sent in the PVC traps. The MIB defines these variables as: 1.3.6.1.4.1.351.1.101.1.17.1.10 1.3.6.1.4.1.351.1.101.1.17.1.11 The Trap sends: 1.3.6.1.4.1.351.1.101.1.17.1.12 1.3.6.1.4.1.351.1.101.1.17.1.13 This has been fixed in databroker process. | ||||||
CSCdk47096 | SV+ sends trap 20003 instead of trap 20011 for UFM port alarms. | ||||||
CSCdk47462 | SV+ still reports 1000 - 1003 event log traps are reported, instead of 1004 - 1007. With this fix only 1004 - 1007 event log traps will be generated with one less varbind than the original 1000 - 1003 traps. | ||||||
CSCdk48096 | Trap 20009 doesn't have slot number as part of the trap format. The format and definition have been updated in SV+ Network MIB. | ||||||
CSCdk48105 | Trap 20009 doesn't provide line number in UXM IMA set up on IGX nodes. This problem has been fixed in emsc process. | ||||||
CSCdk48184 | Connection Manager GUI has been enhanced to accept 125 msec as the minimum CDVRXT for CESM cards in Axis 4.1.02 release or later. | ||||||
CSCdk48793 | When executing pkgadd -d CSCOsv error message "please create group users9" is shown. For this group'users9' has to be created before running pkgadd command. This problem has been fixed in INSTALL program | ||||||
CSCdk50227 | SCM will not come up again, if X-server of the desktop is shutdown while SCM is running, by invoking from SV+ script, after restarting the X-server. This problem has been fixed in SV+ script. | ||||||
CSCdk50328 | ungroup tool deletes the connection and doesn't add back. | ||||||
CSCdk52835 | An intermittent DB inconsistency problem, in which an incomplete PVC(ATM-FR) shown as complete, has been fixed. This problem has been fixed in databroker process. The problem only occurs intermittently during PVC provisioning when the node of the ATM side is not responding and the traps from the AXIS node arrive not in a timely manner. | ||||||
CSCdk52899 | Typographical errors for trap reason codes 92 and 4005 have been fixed in Network MIB. | ||||||
CSCdk53210 | SV+ Topology map doesn't reflect the correct status of ESP nodes. This problem has been fixed in topod process. | ||||||
CSCdk53307 | Error message "Other end CIR out of range for this end card" is returned when adding or modifying ATM-ATM/ATM-FR 2-segment or 3-segment connection. This problem occur only when there is a BXM card on the routing segment of the connection and CIR is set to < 19.2k or SCR is set to < 50. Further problem description: SV+ is enhanced to round up the SCR parameter to 50 for the routing segment if you are adding or modifying the end segment CIR to < 19.2k or SCR < 50. In a 3-seg con case, the end segments will have the user-configured value for CIR or SCR while the middle segment will have SCR=50. | ||||||
CSCdk53395 | SV+ Connection Proxy doesn't use user-input values to set the parameters HiCLP, LoClp, VCQSize, EfciQSize, IBS for ATM-FR connections on AUSM cards in AXIS shelves. | ||||||
CSCdk53677 | Percent utilization set for connections modified using ConnMgr GUI is not updated properly in database as well as on switch. This problem happens only for FRP-FR DAX connections or 2 segment FRP DAX connections (defined as a 2 segment connection where the routing segment is a DAX connection, and the user endpoint on the routing segment is FRP). SV+ ConnMgr GUI allows you to configure the percent utilization on these types of connection. The Modify Connection screen confirms the modified percent utilization parameters. However, the switch CLI display shows the old percent utilization. In fact, the segment entry in the segment table of SV+ database still shows the old percent utilization value. | ||||||
CSCdk54230 | A problem in StrataView subsystems related to synch-up with network has been fixed. This problem occurs usually in large network setup and due to this problem StrataView could take more time to synch-up with the network. | ||||||
CSCdk54488 | Software, Firmware download window doesn't come up from OpenView window, if IGX8450 node is selected. | ||||||
CSCdk54496 | When IGX8450 is configured as the gateway node for SV+, CiscoView is not launched when Equipment Management icon is selected from the Desktop. | ||||||
CSCdk54751 | Connection Manager GUI doesn't list ATM-FR PVCs, when you select the view from FR end. This problem has been fixed in Connection Manager GUI process. | ||||||
CSCdk55470 | Can not delete a 2 segment ATM-CE connection, if the connection was added with CE as local endpoint. Workaround: Add 2-segment with ATM being the local endpoint. After an add, click on the Apply button to list that newly added connection again. Then delete. The apply button triggers CM GUI to get the connection from user_connection table. The query will result in ATM being the local end. | ||||||
CSCdk55524 | Connection manager GUI shows CE-ATM: Cant get segment info from Data-base for modify/delete kind of operations on ATM-CE PVCS. | ||||||
CSCdk56367 | An intermittent exit problem in emc process has been fixed. | ||||||
CSCdk56493 | A problem in PortProxy process, where add port operation on UFM card fails, has been fixed. | ||||||
CSCdk56970 | PortAlarm trap 20011, has only <slot>.<port> in trapIdString. <line> description is missing. | ||||||
CSCdk57648 | In SV+ Topology, once a group has been created by collecting a set of routing nodes, there is no way to access the individual routing nodes without deleting the group. This problem has been fixed in NWTopology process. To access nodes and trunks in a group, two different dialogs - NodeListDialog and TrunkListDialog - have been implemented. The NodeListDialog provides a list of all the nodes in a group along with information about the nodes. Admin, Display Shelf, and SW/FW Images command are provided on the dialog in the form of buttons. The NodeShelfDialog can be invoked by:
Steps (2) & (3) allow you to bring up the TrunkListDialog. | ||||||
CSCdk57649 | Overview map in SV+ topology doesn't get updated, when a layer (background/name/ip address) is turned off/on in the main map. This problem has been fixed in NWTopology process. | ||||||
CSCdk58237 | ConfigDevice window in Equipment Manager GUI doesn't recognize IGX8450 node. If IGX8450 node is selected, an error message 'Unknown Node type' is shown. | ||||||
CSCdk58256 | In Equipment Manager, upline and support features do not function for UXSM card and ALM/A front card with UAI/T3 as back card in IGX8450 node. | ||||||
CSCdk58273 | PCR(0+1) value for a connection on BXM card can not be set to more then 353208 using ConnProxy process. This problem has been fixed in ConnProxy and Connection Manager GUI processes. SV+ service mib has also been updated | ||||||
CSCdk59072 | SV+ forwards trap 20000 in corrupted format. This problem has been fixed in emsc process. | ||||||
CSCdk60151 | StrataView looses registration with AXIS shelves. This happened because of increase of keep-alive timeout in rtm process, by passing `-k 6000' arguments to rtm from /usr/users/svplus/config/watchdog.conf file. To fix this watchdog.conf file has been updated to not to pass `-k 6000' arguments to rtm process. | ||||||
CSCdk60249 | An unexpected exit problem in Connection Manager GUI has been fixed. This happens when `.' (dot) is entered as port number in Port # field and when Apply button is pressed. Fix has been put in to flag an error message if there is any illegal character entered in this field. | ||||||
CSCdk61676 | Trap 20004 returns incorrect trapReason for clear state. The problem has been fixed in SV+Network MIB file. | ||||||
CSCdk62018 | SV+ INSTALL, while installing CiscoView files, displays the error "ERROR: file /usr/users/svplus/wancv/BPX.pkg not found. Exiting". This problem has been fixed in SV+ INSTALL process. | ||||||
CSCdk63006 | Connection Manager GUI, shows incomplete info for data connections. This happens if there are connections with channel number 255 (the permissible range is 2 to 32) in the database. If a connection with channel number 255 is added Connection Manager GUI complains that it is out of range, but continues to add the connection. This problem has been fixed in Connection Manager GUI process. | ||||||
CSCdk63619 | A DataBase inconsistency problem has been fixed in emd and emc processes. This happens when a node gets deleted (leachability) and re-added, and if the management of that node is given to a different emc process than the one previously managing it. In this situation there was a race condition where the previous emc process would be deleting the objects of this node, while the new emc process is getting the objects from the node and updating the database. | ||||||
CSCdk63784 | SV+ INSTALL displays the disk size in number of sectors, instead of bytes as part of the error message, when there is not sufficient disk space on the selected partition to install as Informix database partition. | ||||||
CSCdk63847 | Installation fails with the message "RESIDENT_VAL: Undefined variable". This problem has been fixed in INSTALL procedure. | ||||||
CSCdk64179 | RTM process abnormally exits if you specify Log level 5 in /usr/users/svplus/watchdog.conf file. This does not have any implication as log level 5 is not enabled by default. The regular logging level is 2. Higher logging is only required for getting debugging information during development or when there is some problem reported. There is not problem if Log level 4 is enabled for RTM. | ||||||
CSCdk65319 | SV+ Network Browser doesn't come up if color map allocation fails during its startup. This problem has been fixed in NWBrowser process. | ||||||
CSCdk66274 | The documentation of MIR, PIR, QIR and IBS objects in SV+ Service mib has been updated to mention that these object must be set for FR connections with foresight. | ||||||
CSCdk66461 | Whenever Connection Manager GUI is invoked SV+ admin window shows "/usr/users/svplus/config/insd.conf open failure" error. The problem has been fixed in Connection Manager GUI Process. | ||||||
CSCdk66993 | An intermittent exit problem in Equipment Manager GUI has been fixed. This problem occurs when a DISPLAY SHELF button is clicked, after changing the node selection from the one that is being displayed to a different shelf. | ||||||
CSCdk67145 | SCM will skip sending request to tftp GET the statistics file for some nodes in a random pattern. This results in missing statistics in the database. This problem has been fixed in statsmain process.CSCdk67145: SCM will skip sending request to tftp GET the statistics file for some nodes in a random pattern. This results in missing statistics in the database. This problem has been fixed in statsmain process. | ||||||
CSCdk67623 | SV+ doesn't get registered with AXIS shelves for a long time. If the first attempt to get registered with the axis fails due to axis agent timeout or other SNMP error and the short timeout (in secs) command line option (-s) is set to a high value for rtm process in /usr/users/svplus/config/watchdog.conf file. Further Problem Description: This problem is fixed by decoupling the use of the short timeout value in the error retry delay scenario. Now, the short timeout value is used only for timeout getting response from snmpcomm. This short timeout can be set to a higher value to avoid too many repeated requests sent to snmpcomm while it's busy and end up flooding its message queue. A new command line option "-d" is introduced to set the error retry delay time in seconds. This error retry delay time is used if response is received from snmpcomm but the request failed. In this case, rtm will retry (resend the request) after the error retry delay time. The default for this retry delay is 60s if its not set. | ||||||
CSCdk67623 | INSTALL takes long time. This problem has been fixed in INSTALL script. INSTALL used to take a long time because it used to uninstall CiscoView packages and then reinstall them again regardless of whether you need the packages or not. Now the INSTALL script accepts the user input and if the you need to install packages, it does so else it skips the installation of the CiscoView package files. | ||||||
CSCdk70434 | Test delay feature from SV+ Connection Manager GUII doesn't function, if the SNMP community strings in /usr/users/svplus/config/svplus.conf files are changed, from the default public for GET community and private for SET community, before Connection Manager GUI startup. | ||||||
CSCdk72506 | SV+ Topology sometimes shows grey text on grey background (state of the node). The contrast between the foreground text in dark grey and the background in light grey is low when a row listing an unreachable node is selected in the NodeShelf dialog of SV+ Topology. The lowered contrast is caused by the fact that by default the color of the cell displaying the alarm is reversed when the row is selected. This problem has been fixed in NWTopology process by making sure that the color inversion doesn't take place during the row selection. Also, the contrast has been enhanced by displaying text in bold as well using a color which is opposite of the background color. A text color of white is used when the background is either dark grey (unreachable alarm) or red (major alarm) and black is used when the background is either yellow (minor alarm) or green (no alarm). | ||||||
CSCdk72509 | A selected node or trunk in SV+ Topology is displayed in a different color (purple) than the regular alarm color. Selection of node/trunk is required to execute pull-down menu commands that require either node or trunk as an argument. The normal behavior is a selected node/trunk stay that way (hiding the alarm) until it is deselected or another node/trunk is selected. The problem is when a node/trunk is double-clicked on to bring up a dialog and in the process the node/trunk gets selected although it is not intended. This problem has been fixed in NWTopology process. The problem has been fixed by making sure that before bringing up a dialog on a node/trunk as a result of a double-click on it, the node/trunk is deselected. However, if a node/trunk is selected and then a pull-down menu command is invoked to bring up a dialog, the node/trunk would continue to be selected even after the dialog has gone away. In this case the node/trunk has to be implicitly deselected. | ||||||
CSCdk72513 | An unexpected exit problem in SV+ Topology, when a group icon is selected and the Component->Node->Display Shelf command is invoked, has been fixed. | ||||||
CSCdk72519 | SV+ Topology main map doesn't show the background map while overview map of topology shows the background map. This has been fixed in NWTopology process. This problem happens, if the configuration is saved when the background map is turned off. On subsequent restart of NWTopology, the main map gets displayed without the background map but the overview map comes up with the background map. Turning on the background map layer on the main map toggles the display of background map on the overview window. | ||||||
CSCdk73834 | Configuration Restore to BPX/IGX/IPX does not use block size specified in the /usr/users/svplus/config.sv file. As a result of this, the configuration restore process doesn't show any performance improvement, even after increasing the block size in /usr/users/svplus/config.sv file.This problem has been fixed in configd process. | ||||||
CSCdk75077 | No statistics option appears in Wingz reports menu. This happens because of the missing Wingz worksheet and configuration files from SV+ 9.1 distribution. | ||||||
CSCdk75148 | StrataView plus doesn't receive some of the traps intermittently. This problem has been observed with port delete trap. This problem has been fixed in rtm process. Further problem description: The problem is that rtm process resets KeepAlive Timer (of the src agent) every time when it receives a trap from that agent. If the KeepAlive timer does not get expired, no KeepAlive (SNMPGET ManagerRowStatus) will be sent. So, in a scenario where traps are received continuously from agent by rtm, rtm will delay sending the keepalive everytime it receives a trap. After 30 minutes of continuous trap receipt, the agent will then deregister the trapmgr entry since no keepalive is received from SV+. | ||||||
CSCdk75845 | SV+ SNMP Proxy agent doesn't filter some of the traps like 50600, 50800, 50018, 50500, 50501, 50502, 50021, 50020, 50131, 50303, 25000, 25001, 25002. This trap filter list is installed in /usr/users/svplus directory as rtmIgnoreTraps file. This problem happened because rtmIgnoreTraps file was not included in SV+ distribution. | ||||||
CSCdk76234 | The existing SV+ configuration files are lost during StrataView plus upgrade. The StrataView Plus installation process has been enhanced to restore user configuration files from previously saved set. You can follow the following procedure: The files you want to save are listed in /usr/users/svplus/config/files_to_be_saved with their full path. For example, if /usr/users/svplus/config.sv has to be saved, add this entire path in the files_to_be_saved file. The names should be one per line. Care should be taken to ensure that the file files_to_be_saved always contains the entry /usr/users/svplus/config/files_to_be_saved. Stop SV+ processes Run /usr/users/svplus/install/saveConfig. This will save all the files which are listed in /usr/users/svplus/config/files_to_be_saved in /tmp/.saved.sv. The SV+ INSTALL process has been upgraded to restore config files from this saved set. | ||||||
CSCdk76868 | SV+ Connection Proxy fails to add CAS connections on CESM-8E1 port if the value of svCEEndPointCAS object is set to 2 (yes). This problem has been fixed in ConnProxy process. | ||||||
CSCdk78372 | RtmProxy process is not configured with large timeout value in /usr/users/svplus/config/watchdog.conf file. Because of this any trap manager that is registered with RtmProxy process times out frequently. RtmProxy line /usr/users/svplus/config/watchdog.conf file has been updated to: RtmProxy on. RtmProxy -k 2147483647 | ||||||
CSCdk78908 | socketd process exits in an unexpected manner, if CDE server in whose environment SV+ processes are running, exits abnormally. This problem has been fixed in socketd process. When the CDE session exit, all process with the TTY associated gets SIGHUP signal. socketd does not have handler for this signal that why it exit. When it exit, it does not kill other processes. | ||||||
CSCdk81857 | SV+ doesn't get registered with AXIS shelves for a long time. If the first attempt to get registered with the axis fails due to axis agent timeout or other SNMP error and the short timeout (in seconds) command line option (-s) is set to a high value for rtm process in /usr/users/svplus/config/watchdog.conf file. This problem is fixed by decoupling the use of the short timeout value in the error retry delay scenario. Now, the short timeout value is used only for timeout getting response from snmpcomm. This short timeout can be set to a higher value to avoid too many repeated requests sent to snmpcomm while its busy and end up flooding its message queue. A new command line option "-d" is introduced to set the error retry delay time in seconds. This error retry delay time is used if response is received from snmpcomm but the request was failed. In this case, rtm will retry (resend the request) after the error retry delay time. The default for this retry delay is 60s if its not set. | ||||||
CSCdk84211 | SV+ Service MIB has incorrect range and description for atmEndPointVpi MIB object if the ATM end point is on a NNI port. For UNI port, VPI range is 0-255. For NNI port, VPI range is 0-4095. | ||||||
CSCdk84820 | Inconsistencies between ConnMgr GUI, SV+Service MIB, strata MIB for minimum values of RateUp/RateDown on ABRFS connections on ASI/BXM/BNI cards in BPX and UXM card in IGX has been fixed. Minimum value for RateDown is 1 on BPX/IGX. For RateUp minimum value is 0, for ASI/BXM/BNI cards on BPX and 7 for UXM cards on IGX. | ||||||
CSCdk84925 | SV+ Connection Manager GUI does not show the preferred route properly. This problem occurs when the preferred route contains routing node having "-" as part of the node name. This problem has been fixed in Connection Manager GUI process. | ||||||
CSCdk86036 | Error "Cmgr: nodeName: 0129/99 11:10:38 from Mgr xx.xx.xx.xx :: SET AtmEndptTable Row 1001343 (MODIFY) Local SCR must not exceed PCR(0+1) (10) Agent:Nodename(xx.xx.xx.xx):Agent reported General Error." is return when adding or modifying ATM-ATM/ATM-FR 2-segment or 3-segment connection. This problem occur only when there is a BXM card on the routing segment of the connection and CIR is set to < 19.2k or SCR and PCR are set to < 50. As a fix to this problem cmgrd process has been enhanced to round up the SCR and PCR parameter to 50 for the routing segment if you are adding or modifying the end segment CIR to < 19.2k or SCR < 50. In a 3-seg con case, the end segments will have the user configured value for CIR or SCR while the middle segment will have SCR=50 and PCR = 50. | ||||||
CSCdk86224 | AXIS shelves become unreachable, if different SNMP community strings, other than the defaults settings, for non AXIS nodes are given in /usr/users/svplus/config/svplus.conf file. This problem has been fixed in rtm process. As a work-around to this SV_COMMUNITY string in /usr/users/svplus/config/svplus.conf file can be changed to public and the GET community string on non-AXIS nodes. Set community string can be something other than the default value private. | ||||||
CSCdk87682 | An SV+ station using Net View reports the error "WARNING!! StrataView Topology submaps are not updating. Either SV+ core process are not running, or there is already an OVW session on this display", during startup OpenView processes. This problem was observed in SV+ 9.1.03 (AXI) Patch1 with NetView 5.0. This happens because of wrong default base port usage during SvOvTopology launch. Workaround: Change the base port option in /usr/users/svplus/OV/registration/C/SV_registration file. Application "DAS/DNS Config" Command -Shared -Initial -Restart "/usr/users/svplus/svOvLaunch.s SvOvTopology -b 19500" and restart Net View. | ||||||
CSCdk88603 | SV+ service agent doesn't check whether ATM port type is UNI or NNI for VPI range. The ConnProxy process has been fixed the following ranges. For AUSM card: vpi range is 0-255 for UNI & NNI. For ASI/BXM/UXM: vpi range is 0-255 for UNI and 0-4095 for NNI | ||||||
CSCdk88677 | StrataView NewReports show only performance data if plot duration is selected as TOD. Also the Start Date field must be left empty, otherwise the error "Stop date/time must be later than start date/time" occurs. | ||||||
CSCdk89004 | PVC addition using Connection Proxy agent between CESM 8T1 to CESM 8T1 cards fails with the error "Parameter modification for add channel failed". This problem has been fixed in ConnProxy process. This problem happens because EndPortMaxBugSize defaults to value 10000 in ConnProxy. As a work-around to this one can set value of svCeEndPointBufMaxSize to any value between CDVRxt time 0.7 to 9216 for CESM T1 connections. | ||||||
CSCdk89167 | SV+ ConnProxy reports that CIR, MIR must be greater than or equal to 19200 on remote FR end, if local end is UXM/BXM, while provisioning ATM-FR connections. This problem has been fixed in ConnProxy process. For FRP, FRM, UFM (FR cards on switches) the restriction on CIR, MIR is that both must be greater than or equal to 19,200. This condition is not valid for FRSM cards in AXIS shelves. | ||||||
CSCdk89368 | StrataView may intermittently loose Link 0 /Link 1 access to all the switches in the network, Topology may not get updates for any kind of alarm on the switch. This was observed only one time and that too in a very large network environment, after a network outage due to user error. The problem has been fixed in topod process. Workaround: SV+ can stopped and re-started. | ||||||
CSCdk89649 | StrataView install fails if there multiple entries in the /etc/hosts file with the same host name. It happens even if the entries are commented out. | ||||||
CSCdk89934 | atmEndPointRateDown value description in SV+Service.mib states that range is 0 to 100 for abr-fs. For abr-fs, range should be 1-100%. SV+Service.mib has been modified accordingly. | ||||||
CSCdk90547 | The display of SV+ GUIs like Connection Manager, Stats Collection Manager, malfunction in CDE environment. For CDE support a file called ConnMgr in /usr/users/svplus/app-defaults has been added to SV+ distribution, which specifies the font that should be used when the application is started in CDE. The INSTALL process of SV+ makes a soft link to the above file in /usr/lib/X11/app-defaults directory, so that the font details for SV+ Connection Manager GUI are known to CDE. The window sizes for the SV+ GUI processes like Connection Manager, Stats Collection Manager have been modified, as CDE in some cases need a bigger window size to accommodate all the window components. The font sizes in other related applications have also been modified wherever needed. | ||||||
CSCdk91186 | A database updated problem in emc process, due to which the node table in StrataView DataBase is not updated with the firmware release of AXIS shelves, has been fixed. This problem happens only with AXIS shelves with IP addresses X.0.0.X where X > 0. | ||||||
CSCdk91581 | In a large network (having several hundred nodes), the redundant state changes (redundant messages between SV+ processes) could potentially cause a deadlock between SV+ processes. | ||||||
CSCdk92390 | SV+ INSTALL procedure fails with a error message ` Unmatched `. | ||||||
CSCdk92485 | An intermittent deadlock problem between processes emd and topod has been fixed by throttling number of keep alive messages sent by rtm process to AXIS shelves during one iteration. The deadlock was caused by a blocked by emd process, which was sending axis link status messages to topod. These messages were caused by windup/down messages sent to emd by rtm. | ||||||
CSCdk92758 | A configured preferred route on a PVC is not removable from Connection Manager GUI. This problem has been fixed Connection Manager GUI. As part of this solution Configure button in Connection Manager GUI is not grayed out, when a Clear Preferred route button is selected. | ||||||
CSCdk93082 | If a connection added through switch CLI is modified using Connection Manager GUI, the connection stops working and the connection type gets changed. This happens intermittently. This has been observed when a FR-ATM connection of ATFXFST type is added on switch and CIR value is modified from Connection Manager GUI. The connection stopped working and the type has been changed to SPFTVBR. This problem has been fixed in databroker process. This problem is related to some timing issue, depending on the order in which SV+ receives the add conn robust message from the devices. The problem could occur if SV+ receives add conn message from the node on FR end of the connection before it gets the message from ATM side (BPX). As soon as the add fr conn message is received, databroker populates the conn in the DB as a complete connection. Since it does not know the atm endpoint subtype at this point of time, it arbitrarily picks VBR as the subtype of the connection. The fix is to check the foresight flag on the FR endpoint. If it is ON, populate it as a ABR.FS connection, otherwise VBR connection. | ||||||
CSCdk93192 | SV+ Connection Proxy updates the ICR value while adding or modifying an ATM-ATM ABR1 connection. This behavior is inconsistent with SV+ Connection Manager where ICR field is grayed out while adding/modifying an ATM-ATM ABR1 connection. This problem has been fixed in ConnProxy process. | ||||||
CSCdm00124 | SV+ Network Browser shows that status of 3810 device as unreachable, though 3810 is displayed as reachable in SV+ Network Topology map. As a fix to this problem the management state of a 3810 will no longer be shown as unreachable in Network Browser. Instead a -- would be shown to indicate that the status is not known. | ||||||
CSCdm01892 | SV+ Connection Manager GUI shows ports on cards, which are removed from the nodes, in PortHelpDialog box. This problem has been fixed Connection Manager GUI. | ||||||
CSCdm02239 | SV+ fails to populate database with collected narrow band trunk statistics. This problem has been fixed in statsparser process. | ||||||
CSCdm03319 | SV+ Connection proxy agent fails to modify an existing ATM connection, with atmEndPointMinAdjustPeriod set to a value less than 20. This behavior is inconsistent with SV+ Connection Manager where it allows this value and successfully modifies the connection. This problem has been fixed in ConnProxy process. | ||||||
CSCdm04691 | A problem in watchdog process and some of backend processes which make them terminated or exited in an unexpected manager has been fixed. The problem occurs when control-C is pressed from the same shell script session as the initial SV+ launch. This happens if you press control-C without exiting SV+ menu. Further Problem Description: When control-C is pressed, the Unix kernel sends it to all processes in the same process group. SV+ processes inherited the process group ID from the SV+ launch script. However, some SV+ processes treat control-C as termination request. When they voluntarily exit, watchdog try to restart them again. The problem has been fixed now in a way such that SV+ daemon processes no longer inherit the launch script's process group ID. | ||||||
CSCdm05611 | SV+ Connection Proxy agent fails to add AUSM PVCs if UPC parameters are not specified. The connection addition attempt fails with a error message which says "Wrong ingrQCLPHighThresh value". This problem has been fixed in ConnProxy process. | ||||||
CSCdm06929 | If SV+ window (x-term or shell session from which SV+ menu is used) is closed while stop SV+ core processes option is being executed, some of the SV+ processes may not be stopped properly. Because, of this SV+ doesn't come up properly, when it is started next. Workaround: This problem has been fixed in stop core processes procedure of SV+. | ||||||
CSCdm07087 | SV+ Port Proxy agent fails to add a port on CESM-8E1 card, with the error "svCesmPortTable is not supported for the card: CESM-8" This problem has been fixed in PortProxy process. | ||||||
CSCdm07324 | svPlusL1.log file in /usr/users/svplus/log directory gets the entry "[ConnProxy]GetActiveInsdHostFromFile: fopen[/usr/users/svplus/config/insd.conf, error[2]" added to it very frequently. This happens while ConnProxy process is running. This problem has been fixed in ConnProxy process. | ||||||
CSCdm09211 | SV+ Connection Proxy agent doesn't accept value 0 for atmEndPointRateUP on ATM end point side of ATM-FR ABRFS and ATM-ATM ABRFS connections. This problem has been fixed in ConnProxy process. | ||||||
CSCdm09292 | SV+ imageDonwLoad process fails to download firmware images for FRSM-HS1/B V35 cards in AXIS shelves, from SV+ Topology. This problem has been fixed in imageDownLoad process. | ||||||
CSCdm09566 | SV+ SCM, in integrated environment, fails during startup with the error message "Can't communicate with SV+. Either SV+ is not running or another GUI is already running". The problem has been fixed in SV+ statsmgr process. | ||||||
CSCdm09844 | On SV+ station OpenView reports the error "WARNING!! StrataView Topology submaps are not updating. Either SV+ core process are not running, or there is already an OVW session on this display.", during OpenView processes startup. This problem was observed in SV+ 9.1.06 This happens because of wrong default base port usage during SvOvTopology launch. Workaround: User can change the base port option in /usr/users/svplus/OV/registration/C/SV_registration file. Application "DAS/DNS Config" Command -Shared -Initial -Restart "/usr/users/svplus/svOvLaunch.s SvOvTopology -b 19500"and restart OpenView. | ||||||
CSCdm10618 | Connection Manager GUI does not reflect correct connection status of AUSM 8. This problem has been fixed in emc. The connection manager shows a OK/A-Bit Alarm status on the connections instead of Fail/A-bit status or "Failed" status instead of "OK" status, if a loopback is disabled or enabled on the port on which this connection exists. This problem happens if there is a connection exists on a AUSM 8 port card in a AXIS shelf, and if user enables loopback from a disabled state or disables from a enabled state from Equipment Manager GUI. The above problem has been observed in SV+ 8.4.12 managing AXIS 4.0.16 shelf with AUSM 8 cards. Workaround: User can do node resync on the AXIS shelf from Equipment Manager | ||||||
CSCdm11697 | PVC addition using Connection Proxy agent on a AXIS shelf running release 5.0 and above fails with the error message "Invalid release for AXIS". This has been fixed in ConnProxy process. | ||||||
CSCdm11833 | SV+ Connection Proxy agent fails to modify PCR01 value on ATM-ATM or ATM-FR connections, to a smaller value. This problem has been fixed in ConnProxy process. | ||||||
CSCdm12818 | SV+ Connection proxy agent fails to add a PVC with SCR greater than or equal to 14732 CPS, on AUSM IMA ports. This problem has been fixed in ConnProxy process. | ||||||
CSCdm12903 | SV+ Connection Manageru GUI and Connection Proxy agent do not allow setup of UPC parameters like atmEndPointEfci, atmEndPointHiCLP, atmEndPointLoCLP, atmEndPointVcQSize, atmEndPointIBS on ATM-ATM connections for Ausm on AXIS shelf. The problem has been fixed in cmgrd process. Further problem description: The setting of UPC Parameters for Ausm for ATM-ATM connection is not supported in earlier releases of SV+ 9.1. The setting of UPC parametrs for Ausm is only supported for ATM-FR connections. | ||||||
CSCdm15341 | After repeatedly opening and closing the SV+ Desktop a time may when it will not be possible to have a working Desktop anymore. The NWTopology process will print the warning: WARNING: NWTopology - Failed to connect to topod. Will wait for 60 secs and try again. NWTopology exits after repeating this warning 5 times at which time Desktop will exit as well. This problem has been fixed in NWTopology process. | ||||||
CSCdm15502 | SV+ install script gives the error "/tmp/.saved_sv:No such file or directory". Also it tries to install older version of WANCV, even if it finds a latest version WANCV files on the system. This problem has been observed in SV+ 9.1.06. The error messge problem has been fixed in INSTALL scripts. WANCV release notes has been udpated to caution the user, that while installing if WANCV prompts the user whether to install a older version of WANCV software or not, user is required to decline by typing No. | ||||||
CSCdm15555 | SV+ installation doesn't have an option to upgrade from a previous releases of 9.1 to the current release of 9.1. This problem has been fixed in INSTALL scripts | ||||||
CSCdm17672 | An intermittent exit problem in cmgrd process has been fixed. This problem happens intermittently at the time PVC deletion request and it occurs only when the DataBroker process is busy processing connection or alarm messages from the network | ||||||
CSCdm18580 | An intermiitent exit problem in emd process has been fixed. This was observed when manual resync operation is done from Equipment Manager GUI with an AXIS shelf. | ||||||
CSCdm20291 | SV+ manual install fails, if groups svplus and informix are not added to the system, prior to adding SV+ CSCOconf package. Workaround to the above problem, one can add svplus and Informix groups to the system before running SV+ manual install. | ||||||
CSCdm20301 | SV+ install gives the error Can not open /usr/users/svplus/svplus.conf file. This problem has been fixed in SV+ INSTALL scripts. | ||||||
CSCdm20626 | SV+ SCM error pane shows the dates on the statsfiles with 2 digit year field. These are error messages only and do not have any direct effect on Y2K compliance. This problem has been fixed in statsmain process. |
The following Year 2000 anomaly was fixed in SV+ 9.1.07.
| Bug ID | Descriptions |
|---|---|
CSCdk89132 | In SV+ New Reports, 2/29/99 (DD/MM/YY) is accepted as a valid date in Performance Data window. This is an error, because 1999 is not a leap year. |
The following anomalies have been corrected in Patch 2 of the 9.1.07 release of StrataView Plus.
| Bug ID | Descriptions |
|---|---|
CSCdm50410 | HPOV topod.log shows SV+ station as the source of traps instead of BPX/AXIS. |
CSCdm38578 | telnet to the WAN devices (BPX/IPX/IGX) does not echo user name and does not work. Workaround: Set the telnet session to char mode. For more details on how to do this, please see the "third party limitations" section. |
CSCdm63914 | The trunk robust messages for packet line were not getting parsed for 8.2.5x SWSW. |
CSCdm50556 | All the traps received from BPX/IGX are shown with source as svplus station rather than the BPX name. |
CSCdm37103 | Customer is collecting statistics using Raw Data Report. When the node is selected from the Target Node/Shelf Window, the information displayed in the window labeled Objects Available is inconsistent from information about the nodes, displayed using the dsptrks command or when using the New Reports. |
CSCdm70853 | The installation gives the following error messages: "StrataView Events is not a valid category Enterprise record not found." |
CSCdm41565 | SV+ auto-install fails on AIX systems running OS release 4.2.1 or later because of a conflict between svplus group id(21) and system shutdown group id (21). |
The following anomalies have been corrected in Patch 1 of the 9.1.07 release of StrataView Plus.
| Bug ID | Descriptions |
|---|---|
CSCdm31948 | The attempts get PVC info using SV+ SNMP Agent fail on FR side for ATM-FR connections. This problem has been fixed in ConnProxy process. |
CSCdm38892 | Intermittently SV+ desktop might not be able to bring Equipment Manager GUI upon selection to manage release 4.0.X AXIS shelves. This problem has been fixed in Desktop process. |
CSCdm39168 | SV+ Connection Manager GUI doesn't show the right A-bit status of the connection, when a loop back is removed and added back. Connection Manager GUI shows the A-bit status as failed, though the switch has it in OK/Clear status. |
CSCdm41838 | SV+ database shows a non-existent connection in the network. This happens even after starting the StrataView process after creating the database using "create_db" utility. This problem happens intermittently and has fixed in create_db tool. |
CSCdm42155 | An intermittent exit problem in eventd process has been fixed. Because of this problem, the following error message is continuously shown on SV+ console: "<write_till_finish>: write failed,errno=32,wrote 0 of 2 bytes, ...." The problem usually happens when a lot of alarm messages are received by SV+ from the switch. This has been observed only in large network environment. The problem has been fixed in eventd process. |
CSCdm43968 | When CiscoView is invoked using Equipment Manager button in SV+ Desktop, the following error message is displayed, "Unable to invoke equip. management. CV is not installed or not integrated". This problem occurs only on AIX platform. This problem has been fixed in IntegrateCV script. |
The following anomalies of the 9.0 release of StrataView Plus have been corrected and rolled into the 9.1.07 release of StrataView Plus.
| Bug ID | Descriptions |
|---|---|
CSCdk08930 | A problem related to managing more than 9 networks in emd process has been fixed. This problem shows up in the form of the emd process dying and getting restarted multiple times. This in turn makes the SV+ database to be inconsistent with the status and configuration of Axis nodes in the network. This has been noticed in a multi-network environment where there are more than 8 networks being managed by SV+. The problem was caused by the fact that topod was busy when emd comes up and tries to register with topod. This has been fixed by making sure that topod doesn't subscribe to the network before all the core clients including emd have registered so that the client will be able to register successfully. Also a retry mechanism has been implemented in emd. |
CSCdk17392 | In Connection Manager GUI, DE to CLP mapping is not available for FR-ATM connections. This problem has been fixed in Connection Manager GUI process by enabling the "Set CLP Zero" and "Set CLP One" for Channel types SIW-Transparent and SIW-Translate. |
CSCdk45939 | The % util field in ConnManager is not updated when PCR(0+1) value is changed for ATM-ATM connections. |
The following anomalies of the 8.4 release of StrataView Plus have been corrected and rolled into the 9.1.07 release of StrataView Plus.
| Bug ID | Descriptions | ||||
|---|---|---|---|---|---|
CSCdj59952 | When using the MIB browser in NetView for BPX node in the StrataView map, the nodename is postfixed -BPX. As a result MIB browser doesn't understand if this name is given. In release SV+ 8.4.10 in the routing level map, all bpx nodes label and selection names are constructed from node names suffixed with "-hub". In the feeder level map, the label and selection name of the core shelf are the same as the node name. Select the core shelf for the BPX node in the feeder level map to launch MIB Browser. For IPX, IGX and AXIS, select the respective node and launch MIB Browser. The name/IP address displayed in the MIB Browser will be correct. As a work-around for the above problem the core shelf for the BPX node can be selected from the feeder level map. Then from the Misc menu, if SNMP MIB Browser is selected, the name/IP address displayed in the MIB Browser will be correct. | ||||
CSCdj92179 | The operation for modification of preferred route only through SV+ connection proxy agent is deemed not efficient. A performance enhancement targeted to this specific operation has been done in ConnProxy and cmgrd processes. | ||||
CSCdk09192 | A problem in configd process which makes the loadcnf command given from BPX/IPX/IGX CLI abort has been fixed. This could happen if IP network is prone to drop packets. When configuration packets going from SV+ to a switch get dropped, the retry (retransmission) mechanism in SV+ does not work and loadcnf aborts. The work-around for this to use loadcnf command on the switch when the network is less used. | ||||
CSCdk11108 | SV+ SNMP proxy returns no variable found, when a query is made on MIB variable svMapLogicalPort for non-channelize frsm-8 card. This problem has been fixed in PortProxy process. | ||||
CSCdk12069 | Node resync operation in Equipment Manager GUI fails with Axis shelves running release 4.0.13 software. This problem has been fixed in emc process. | ||||
CSCdk12201 | User connection is not reset back to OK state when connection is re-established. This problem has observed on CESM-CESM connections in SV+ 8.4. This problem has been fixed in Connection Manager GUI process. | ||||
CSCdk21635 | Non existing trunk appear intermittently on SV+ Topology and NetView Topology maps. This problem has been observed in SV+ 8.4 usually after swithcc operation is done on 8.4 SWSW network. The problem has been fixed in topod process.v | ||||
CSCdk22603 | SCM appears to get stuck when it is trying to reach timesync host. This problem could happen in either of these conditions.
This problem has been fixed in statsmain process. With this fix the default retry time to sync with timesync host is 5 minutes and this can be set to anywhere from 4 to 14 minutes by a environment variable TIMESYNCPERIOD. When the above problem happens one can exit SCM and set this TIMESYNCPERIOD to a value more than network response time for timesync host status and then start SCM. This time if timesync host is not reachable, you will be able to change the timesync host from SCM in NodeConfig parameters. Further Problem Description: There was a problem in the way the time sync host was contacted by SCM. If the time sync host was unreachable then a particular host may kept on gutting retried. | ||||
CSCdk30217 | Different SNMP community strings other than the default settings are not supported for VNS. VNS is shown as unreachable on SV+ if the SNMP community strings on VNS are changed from default. This problem has been fixed in rtm process. | ||||
CSCdk36049 | SV+ database table 'column1' shows wrong information in column 'l_line'; the l_line field has value 255. This problem applies to circuit lines on IPX, IGX and BPX only. This problem has been fixed in emsc process. | ||||
CSCdk36749 | Equipment Manager GUI shows 'wrong value' error message when a port is added on FRSM-HS1 with X.21 back card. This problem has been fixed in Equipment Manager GUI process. This problem can occur in the following ways:
| ||||
CSCdk36752 | An intermittent problem in SV+ install where the install process hangs has been fixed. The problem is in ilog_cleanup tool which is used by the install process. | ||||
CSCdk45447 | A problem in Equipment Manger GUI, where it displays incorrect information if a slot number field on Equipment Manager: Configure Port Dialog is changed, has been fixed. | ||||
CSCdk50180 | Equipment Manager GUI, displays "Port configured does not match the current filter" error message, after a port is successfully added. This has been observed when a port is added on FRSM-HS1 card. | ||||
CSCdk60860 | Following BPX statistics have been added to SV+ Stats Collection Manager:
| ||||
CSCdk65341 | Equipment Manager GUI, displays "DS0 BitMap is Wrong for E1" error message, when an attempt to up a E1 port on FRSM card with CAS signalling is made. | ||||
CSCdk67023 | .SV+ does not get registered to the AXIS nodes for a long time. This problem happens if the first attempt to register to the AXIS fails due to AXIS agent time-out or other SNMP error and the short time-out (in secs) given by command line option (-s) to rtm process is set to a high value. Further Problem Description: This problem is fixed by de-coupling the use of the short time-out value in the error retry delay scenario. Now, the short time-out value is used only for time-out getting response from snmpcomm. This short time-out can be set to a higher value to avoid too many repeated requests sent to snmpcomm while its busy and end up flooding its message queue. A new command line option "-d" is introduced to set the error retry delay time in seconds.This error retry delay time is used if response is received from snmpcomm but the request was failed. In this case, rtm will retry (resend the request) after the error retry delay time. The default for this retry delay is 60s if its not set. | ||||
CSCdm09863 | Statistics Collection Manager GUI shows excessive timed out messages to time sync host.This problem has been fixed in stasmain process. As a fix to the above problem, statsmain has been enhanced to try connecting to time sync host 15 times, whenever it receives Node Is Busy or Connection Under Progress type of failure cases, before giving up and record Failed error. For all the other failed cases SCM reports Failed error and logs the error in its log file. |
This section describes known anomalies in the 9.1.03 version of StrataView Plus.
The following conditions in the previous releases of SV+ have been corrected with the 9.1.03 version of StrataView Plus.
| Bug ID | Descriptions |
|---|---|
CSCdj63461 | The status for CESM connection gets updated with an undefined value 143. This has been fixed in emc process. |
CSCdj64376 | An intermittent error log problem in emc process has been fixed. emc logs IMATM card with trunk ports as unknown card type in its log file /usr/users/svplus/log directory. CSCdj87578: Wingz data report shows UFM-E1 narrow band trunk category. CSCdk21052: After SV+ install Wingz reports tool may not work due to some file permission problem. This has been fixed in SV+ install procedure. As a work-around, execute the following commands. # ln -s /usr/users/Wingz/DataLink/DBLink /usr/users/Wingz/DBLink # chown -R svplus /usr/users/Wingz # chgrp -R svplus /usr/users/Wingz |
CSCdj87578 | Wingz data report shows UFM-E1 narrow band trunk category |
CSCdk21052 | After SV+ install Wingz reports tool may not work due to some file permission problem. This has been fixed SV+ install procedure. As a work-around, execute the following commands. # ln -s /usr/users/Wingz/DataLink/DBLink /usr/users/Wingz/DBLink # chown -R svplus /usr/users/Wingz # chgrp -R svplus /usr/users/Wingz |
CSCdk21512 | A problem with DB consistency, during SV+ warm-start has been fixed in emc process. SV+ DB doesn't get updated properly during warm-start if some FRSM channels are deleted while SV+ is not running and SV+ is warm-started after this deletion. |
CSCdk21838 | Communication break alarms 20016 and 20017 are not getting generated, instead 20006 and 20007 get generated. The trap numbers were changed in 9.1, the correct trap numbers are 20016 and 20017. |
CSCdk22503 | The tbcount, dbcount and svdbcount scripts in /usr/users/svplus/tools directory are not functional. |
CSCdk23023 | ATM-FR connections can't be added using SV+. An attempt to do so fails with the error message from switch Agent: "Interworking ATM-CONS are not allowed" or "Remote card is inappropriate type (AIT)" This happens when the FR side is an IPX/IGX feeder connected to an IGX hub. This happens because SV+ tries to add the middle segment with subtype=vbr or abr, but it results in error because BTM does not support vbr/abr. |
CSCdk25344 | Trap 20004 generated after a switchcc on BPX gives undefined values for trapReason (3055) and trapCardStatus (4). This problem has been fixed in emsd process. SV+Network.mib has also been updated. |
CSCdk28176 | NWTopology process exits intermittently in an unexpected manner. |
CSCdk29857 | EMGUI will not show the correct line status if there is any alarm or the alarm is cleared. Also the connection status shown on CMGUI will be incorrect in case of alarm of if the alarm is cleared on FRSM or any other card related to following traps: dsx1LineNoAlarmTrap (50120) dsx1LineInAlarmTrap (50121) dsx1LineLpbkEnableTrap (50122) dsx1LineLpbkDisableTrap (50123) As a work-around to this SV+ can be restarted. |
CSCdk30796 | The create_db process in SV+ doesn't create stored procedures if it is run by user root. |
CSCdk33349 | Alarm state of lines of SRM card shown on Equipment Manager GUI line configuration are not correct. The problem has been fixed in Equipment Manager GUII process. |
CSCdk34194 | Traps 25010, 25011, 25012 do not contain correct svConnType if they are generated on ATM-FR connections. |
CSCdk37660 | SV+ AIX install fails with Informix errors. This problem has been fixed in the install procedure. INSTALL Script is not creating the symbolic link from /usr/lib directory to /usr/users/informix72/lib directory for the library : ismdd07b.o As a work-around to this problem the following command can be run as user root, before running SV+ install procedure. # ln -s /usr/users/informix72/lib/ismdd07b.o /usr/lib/ismdd07b.o |
The following anomalies have been corrected in Patch 1 of the 9.1.03 release of StrataView Plus.
| Bug ID | Descriptions |
|---|---|
CSCdk70853 | SV+ INSTALL gives the following error messages: "StrataView Events is not a valid category Enterprise record not found" This problem has been observed during SV+ 9.1.03 (AIX) install process |
CSCdk70884 | SV+ INSTALL gives the following error messages: "cp:/var/opt/OV/share/snmp_mibs/Vendor/cisco/: a file or directory in the path does not exist." This problem has been observed during SV+ 9.1.03 (AIX) install process. |
CSCdk71215 | On certain AIX systems, SV+ has problems in coming up, as port 9000 is in use by x_st_mgrd. One can find x_st_mgrd 9000/tcp entry in /etc/services file. To avoid this problem, base port used by SV+ has been changed to 19500. |
The following anomaly has been corrected in the 8.4 release of StrataView Plus and rolled into the 9.1.03 version of StrataView Plus.
| Bug ID | Descriptions |
|---|---|
CSCdj84298 | Wingz does not display object for selected line statistics for E1 line type. |
The following conditions have been corrected in the 8.4 release of StrataView Plus and rolled into the 9.1.03 version of StrataView Plus.
| Bug ID | Descriptions | ||||
|---|---|---|---|---|---|
CSCdj52072: | Connection Manager GUI does not allow value=0 for %util parameter on BXM card with serviceType=UBR. The problem exists for connections UBR.1 and UBR.2 service types involving BXM cards. A work-around for this is to use CLI to modify the %util value to zero. | ||||
CSCdj63905: | Equipment Manager GUI does not reflect the correct color for administrative state on SRM3T3 in release 4 AXIS shelves. This problem happens because of improper handling of the related trap by emc process. The problem has been fixed in both Axis firmware and StrataView Plus releases. Axis fix is in release 4.0.13 or later. The workaround for this is to do a node resync from Equipment Manager GUI after disabling the line. | ||||
CSCdj72753: | The documentation error regarding atmEndPointMinAdjustPeriod object in SV+Service.mib has been fixed. The range now has been changed to 3 to 255. | ||||
CSCdj77436: | SCM may not collect statistics files 12 collection cycles back if the history files are set to >= 12. This problem has been fixed in statsmain process.This problem only occurs if the number of history files to collect is set to >= 12. | ||||
CSCdj78846: | Unable to collect the following statistics via TFTP from BXM trunk lines when selected from SV+ stats manager: Further explanation of the problem FEBE Count This fix is done in Switch Software. The rest of the missing counters are fixed in StrataView Plus SCM. | ||||
CSCdj80624 | The status of a trunk in the packet_line table of SV+ DB is inconsistent with the status displayed in the CLI of the switch. The packet_line table is written to by both topod and emsd although to update different sets of attributes. But this may at times create the scenario that when either of them is writing the other also tries to write which fails and as a result the database may not get update with the correct values for some of the attributes (trunk status in this case). This gives rise to database inconsistency. This problem has been fixed in topod and emsd processes by introducing retry mechanism for DB writes | ||||
CSCdj83864: | CM GUI differs from SNMP/CLI in configuring CLLM ports. You cannot change the cllm enable, and timer when the fr port is configured to LMI or UNI protocol type, in the Equipment Manager GUI. | ||||
CSCdj85527: | SV+ install script overwrites the perl executable in /usr/local/bin with the version bundled with StrataView media. This problem has been fixed SV+ INSTALL procedure. A work-around for this problem is to save the existing copy of perl before the install and restore it back in /usr/local/bin after StrataView installation. | ||||
CSCdj88137: | TestConn returns erroneous data in SNMP for FR-ATM PVC. The returned values do not match with the values described in SV+Service.mib file. This problem has been fixed in ConnProxy process. The above problem happens if a TestConn is executed for a FR-ATM connection from the ATM end and if the test is successful, the test result returned actually contains the delay, a positive integer value, rather than the expected 0. As a work-around for this any positive value returned can be considered as success. | ||||
CSCdj89037 | :statsparser process fails to parse stat files collected from AXIS shelves with the following error message in /usr/users/svplus/statsmgrdir/statsparser.err file. "Mar 17 17:17:00 ERROR:0 statsparser.c@668:File:/usr/users/svplus/incoming/<axisnodename>.0317981700 Mar 17 17:17:00 ERROR:0 BinaryProcessor.c@258: This problem happens only with release 4.0.09x Axis shelves. | ||||
CSCdj89302: | When statistics collection is in progress SCM does not warn you while exiting that statistics collection will be stopped upon exit. | ||||
CSCdj89609 | Strata View Plus Equipment Manager GUI shows BNM Clock Source as AUM Inband instead of BNM Inband. This problem has been observed with Strata View 8.4.10 manager Axis shelves with release 4 or higher BNM cards. | ||||
CSCdj89825 | :When a SNMP GET operation is done on the ServiceMib object svPortIfType and svAtmPortIfType for a port on a BXM-12T3 or BXM-8T3 card, the Port Proxy Agent returns the wrong value of 16 which is oc12-smf. The correct value should be 4 for t3. Similar problem happens to BXM-8E3 and BXM-12E3 cards also, for which the correct value is 5 for e3. | ||||
CSCdj91893: | OpenView trapd.log file shows some Axis traps in no defined format. This could happen if traps from axis.mib are loaded (using OpenView menu options etc.), prior to StrataView installation. This has been observed in StrataView 8.4.10. The work-around for the above problem is available only for Axis traps 50120-50123. Login as root and run following commands from /usr/users/svplus directory: # /opt/OV/bin/xnmevents -delete dsx1LineNoAlarmTrap dsx1LineInAlarmTrap\ dsx1LineLpbkEnableTr dsx1LineLpbkDisableT # cd /usr/users/svplus # ./SV+_HPOV.install The above problem has two parts | ||||
|
These missing traps have been added to StrataView's StrataCom_trapd.conf file. | ||||
CSCdk01192: | When adding a BXM or ASI port that is already existing, the error message in the error table is incorrect. The error message reported the wrong port with a bogus shelfName, in the format "Port routingNodeName.shelfName.slot.port already exists". The correct error message should not have the shelfName. This problem has been fixed in PortProxy process. | ||||
CSCdk07105: | When trap 50045 is received, the HPOV event browser dumps the varbind list instead of trap description string. This trap is generated when secondary card becomes active as the primary card fails. | ||||
CSCdk07451: | For userLogoutTrap (55021) from axis, OpenView event browser shows incorrect value in user field. | ||||
CSCdk09486: | A database inconsistency problem related to user_connection table has been fixed in emsc process. Because of this problem entries in user_connection table do not match with status on network and atm_connection table. This problem could happen if addition and deletion of connections on the same switch are done at a rapid rate or when SV+ is down. As a work-around for this problem SV+ database can be re-created and SV+ can be started | ||||
CSCdk10508: | A database inconsistency issue related to logical connections has been fixed in emsc process. SV+ database table logical_conn contains rows that do not correspond to any existing connection. These rows are leftovers from connections that have been deleted. This problem can happen if connection addition & deletion is performed while SV+ is down or if SV+ is up but the network is busy. As a work-around for this problem SV+ database can be re-created and SV+ can be started. | ||||
CSCdk10837: | Equipment Manager GUI shows the primary slot as empty after the cold start even though the primary card is covered by the secondary card. It should show the primary card as covered slot. This problem can happen in the following scenario. When primary and secondary cards are setup and then primary card is removed while SV+ is running, Equipment Manager GUI shows the secondary card as active and the primary card as covered slot. If SV+ is then stopped and restarted after creating SV+ database, Equipment Manager GUI shows the primary slot as empty. As a work-around for this the primary card can be inserted back into the slot. | ||||
CSCdk11895: | Equipment Manager GUI displays incorrect values for rcv/xmt AIR counter values for FR-channels, in the view counter screen. This problem happens if the network has Axis 4 shelves with FRSM-4 cards and SV+ is 8.4.09, 8.4.10 or 8.4.11. | ||||
CSCdk13002: | As a work-around to this problem, the line field in Equipment Manager GUI Port configure window can be left out. This results in ports on line 4 displayed along with the other ports. | ||||
CSCdk13155: | In a redundancy card setup, when a secondary card takes over in primary card failure situation, no new ports or PVCs can be added to the primary card, if the primary card is pulled out. This problem has been fixed in emc process. This problem has been observed with SV+ 9.1.02 and prior releases managing release 4.0.12 or later Axis shelves. | ||||
CSCdk13162: | StrataView node resync with axis shelves fails. This problem happens only when any redundancy action occurred like softswitch, primary card failed or pulled out. In such cases the SV+ database will be out of sync with axis shelves. This has been observed with StrataView 8.4.11 managing Axis 4.0.13 shelves. This problem has been fixed in emc process. | ||||
CSCdk14193: | As a work-around to this problem, node resync can be opted from Equipment Manger GUI. This will update the GUI with line distribution status. | ||||
CSCdk14782: | An intermittent exit problem in Desktop process has been fixed. This problem has been observed when SV+ processes are stopped while Desktop is running. | ||||
CSCdk21314: | The equipment management subsystem (emd, emc processes) and DataBase schema have been updated to support the new card state reserved in Axis releases 4.0.16 onwards. Axis send this reserved state if a card is pulled out from its slot. In Equipment Manager GUI a card in this state will be shown as empty slot. | ||||
CSCdk22603: | SCM appears to get stuck when it is trying to reach timesync host. This problem could happen in either of these conditions.
This problem has been fixed in statsmain process. With this fix the default retry time to sync with timesync host is 5 minutes and this can be set to anywhere from 4 to 14 minutes by a environment variable TIMESYNCPERIOD. When the above problem happens one can exit SCM and set this TIMESYNCPERIOD to a value more than network response time for timesync host status and then start SCM. This time if timesync host is not reachable, you will be able to change the timesync host from SCM in NodeConfig parameters Further Problem Description: There was a problem in the way the time sync host was contacted by SCM. If the time sync host was unreachable then a particular host may kept on gutting retried. | ||||
CSCdk24102: | Maintenance logs (event logs) on switches are logged but do not immediately appear in NetView event browser. Sometimes the delay is very significant, i.e.,in hours. Traps may seem to be bursted into NetView event browser every 2 to 3 minutes. This has been fixed in eventd process. The problem occurs when a new switch is added to the network, but not yet added to SV+ workstation(s) local /etc/hosts file or on the DNS server. The problem also occurs whenever the entire network status changes. As a work-around to this problem an entry with node name "NETWORK" (all capital letters) and a dummy IP address can be added to SV+ workstation(s) local /etc/hosts file (or to SV+ system(s) hosts database if /etc/hosts is not consulted by system running SV+). Prior to introducing a new switch to the network, the node name and its IP address should be added to the SV+ workstation(s) local /etc/hosts file (or to SV+ system(s) host database if /etc/hosts is not consulted by system running SV+). If for whatever reason, the symptoms occur, try to "ping" all the nodes and node "NETWORK" from the SV+ workstation(s). If any node is unreachable, add the node name to local /etc/hosts file (or to SV+ system(s) hosts database if /etc/hosts is not consulted by system running SV+). A work-around to this is to select a IPX/IGX feeder which is connected a BPX hub or connection can be added using CLI. | ||||
CSCdk24394 | If the softswitch command is executed on CLI to switch primary card to secondary card in redundant card setup, the PVCs on primary card are stayed in failed state on SV+ CMGUI. even though the PVCs on AXIS shelves and switches are in clear state. This problem has been fixed in emc process. As a work-around for this problem, StrataView can be cold started (clearing the DB and restarting SV+). | ||||
CSCdk28135: | Checksum error is shown in statsmain error log even though the collected statistics file is not corrupted. This problem has been fixed in statschild and statsparser processes. This problem occurs when the collected statistics file is of such a size such that the checksum straddles two blocks. Each block is assumed to be of size 4096. Further Problem Description: The child process on getting the statistics file validates it using the checksum at the end of the file. When this checksum straddles two blocks of size 4096, StrataView checksum computation procedure breaks down and flags the file as corrupt.The child process on getting the statistics file validates it using the checksum at the end of the file. When this checksum straddles two blocks of size 4096, StrataView checksum computation procedure breaks down and flags the file as corrupt. | ||||
CSCdk33001: | Statistics collection won't get completed on nodes running 8.4.X SWSW. This problem has been observed when running SCM with SV8.4.11.Patch2 and SCMSA_8.4.11.Patch2 on 8.4.X nodes. This problem has been fixed in statschild process. |
When installing statistics collection management (SCM) over existing 9.1.X SV+, there are two procedures to follow to get the correct behavior for SCM autoenable and config files.
The SCM has a master file used to autoenable a switch during statistics collection.
In the /usr/users/svplus/statsmgr directory, enable.master.81.stats is a binary file that is sent to the switch when autoenable is invoked. It comes initially set to 60 minute collection and 60 minute buckets for statistics and a limited set of statistics for Frame Relay.
During normal operation, when a you select new statistics or different collection intervals, this file is reset to whatever values you have selected in your configuration and setup.
If a you install a new 9.1.X over an existing environment, the enable file will be overwritten to the defaults. To avoid this, move the enable.master.81.stats file to a temporary file then move it back after install. Or you can bring up the SCM GUI, select the statistics as desired, send statistics enable to the network, and the enable file will automatically be overwritten by your settings.
The SCM has a master file used to setup the selected statistics in the user interface.
In the /usr/users/svplus/statsmgr directory, statsenablelist.stats is a ASCII file that is used to initialize the list boxes for statistics in the GUI. The file is initially set to a limited set of statistics for Frame Relay.
During normal operation, when a you select new statistics, this file is reset to whatever values you have selected in your configuration and setup.
If you install a new 9.1.X over an existing environment, the file will be overwritten to the defaults supplied on the install file. To avoid this, the you can move the file to a temporary file then move it back after install. Or you can bring up the SCM GUI, select the statistics as desired and select the OK button in the window. The file will automatically be overwritten by your settings.
Some users who will be doing redundant file collection and others who will be using multiple SCMs to collect files to a common SV+ workstation. The restrictions that are discussed here apply to both configurations. Refer to Figure 3 Multiple Statistics Collection Manager Configuration below.

There are SV+ WingZ and Parser considerations if you are using multiple SCMs for TFTP Statistics collection. When you configure a node for TFTP collection, the SCM keeps a copy of the node configuration on the LOCAL SCM workstation.This configuration list is used by WingZ to determine what statistics have been enable/disabled on a given node. In order for WingZ to turn on the statistics enable table, these configuration files are opened and parsed by the SV+ statsenable program, and the database "stat_enable" table updated for that node.
It is recommended that you use a single SCM to enable all TFTP statistics for all nodes in the network. The single SCM should be the SCM that runs on the same workstation as WingZ and SV+.
It also important to note, that the Network Parameters window on the SCM that is running stand-alone contains configuration parameters for the statsParser. Since the SCM is running stand-alone where there is no statsParser or SV+, the Parser parameters will have no effect upon other SCMs running on other machines. If you want to change a statsParser parameter, you must go to the machine where SV+ and the parser are running and configure the parameters appropriately for them to take effect
The auto enable feature is only available in SCM which is running along with SV+ core processes. Stand alone SCM does not have auto enable functionality. The function of auto enable is to do TFTP put statistics enable to the nodes which are configured to have statistics master SCM as this one. This is done when SCM first starts up. If no statistics enable file was sent to a node from this SCM, it will send a default enable.master.81.stats file; otherwise, SCM will send the same stats enable file which was sent by this SCM to that node previously.
The important note for this auto enable feature is that there is no provision to turn this feature off. The side effect is that after the installation of SV+ 9.1.X, for the first time when SCM is run, it will put the default enable.master.81.stats file to all the nodes which are configured to have stats master SCM as this one. In this case, if you do not want default statistics, you must again select the statistics and send to the nodes.
The other important note for SCM in 9.1.X is that the stand alone SCM uses YP page if ypbind is running otherwise it uses local /etc/hosts file to get the nodes name. On the other hand, SCM which is running with SV+ core processes, gets all the node from topology.
SCM 9.1.X does not support local host or any UNIX work station as time sync node. You must select one of the routing node for time sync node.
SCM 9.1.X allows different groups of nodes to have different bucket intervals, collection intervals and time sync nodes. However, the main window in SCM always displays the most recent settings of network parameters. They are valid for those nodes which were enabled and done start collection, after these parameters were set. To see the collection period, bucket interval and time sync node, you can select a node and apply Show Collect Info from node selection window.
For service and support for a product purchased from a reseller, contact the reseller. Resellers offer a wide variety of Cisco service and support programs, which are described in the section "Service and Support" in the information packet that shipped with your chassis.
For service and support for a product purchased directly from Cisco, use CCO.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.

![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Jun 27 15:03:12 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.