|
|
This chapter describes the installation and removal of VISM front and back cards in an MGX 8850 shelf. The installation procedure for installing new VISM software versions is also included.
VISM cards are single height cards. Installation of a VISM card set in an MGX 8850 Wide Area Edge Switch consists of installing one front card and one back card (if not in bulk mode) in either an upper or lower shelf slot. Slots 1-6, 9-14, 17-22, and 25-30 are available for VISM cards (see Figure 2-1).
Using all the available slots, the MGX 8850 can be configured with up to 24 VISM cards with the following restrictions.
The two lower shef cellbuses can each sustain a bandwidth of one OC-3/STM-1 link. For example, this bandwidth limits the number of E1 ports on the lower shelf, when using the G.711 codec, to 78 (approximately 10 VISMs).



Step 2 Gently slide the card all the way into the slot and press the insertion/extractor lever until it snaps into the vertical position.
![]() |
Note The card should slide in and out with only slight friction on the adjacent board's EMI gaskets. Do not use force. Investigate any binding. |
Step 2 Position the rear card guides over the appropriate slot at the top and bottom of the card cage.
Step 3 Gently slide the card all the way into the slot and tighten the two captive screws on the back card's faceplate. Tighten the upper and lower screws to prevent misalignment of the card. Do not overtighten the screws. Tighten only enough to secure the card.
Step 2 Gently pull the card out of the card cage.
Step 2 Use a flat screwdriver to undo the two retaining screws in the back card's faceplate.
Step 3 Pull both of the two extractor levers out to the horizontal position. This action will start the removal of the card. Gently pull the card out of the card cage.
VISM releases 1.5.05 and later provides a procedure for the graceful upgrade (one in which the existing VISM configuration is preserved throughout the upgrade procedure) froman earlier software release (Release1.5.03 or later) to the current (or later) software release.
Initial Conditions
The following intitial conditions are required before the graceful upgrade procedure can be started.
Upgrade Procedure
In the following procedure:
Step 2 Execute the PXM install command:
install sm<SM slot#><new-rev>
where:
SM slot# is the slot number of the VISM 2 card and new-rev is the file name ot the new firmware ( for example vism_8t1e1_1.5.0_5.fw).
This command causes the standby VISM 2 to reset and come up in the "hold" state, running the new-rev firmware.The active VISM 1 is unaffected by this command. At this point the primary firmware still the old-rev and the secondary firmware is new-rev.
Step 3 Execute the PXM newrev command:
newrev sm<SM slot#><new-rev>
where:
SM slot# is the slot number of theVISM 2 and new-rev is the filename of the new firmware.
This command causes the VISM 2 to become the active VISM running the new-rev firmware. The previously active VISM 1 changes to a "hold" state and is still running the old-rev firmware. The primary and secondary firmware switches with the new-rev becoming the primary firmware.
Step 4 Execute the PXM commit command:
commit sm<SMslot#><new-rev>
where:
SM slot# is the slot number of the standby VISM 1 and new-rev is the filename of the new firmware.
This command causes both VISMs to run the new-rev firmware. At first, VISM 2 is the active VISM with VISM 1 remaining in the hold state. After a short time, the cards switch automatically with
VISM 1 becoming the active card and VISM 2 the standby card.
The two VISM cards are now back to their original condition exept that both cards are now running the new-rev firmware.
Step 5 Logon to the active VISM card and use the display commands (dspendpts, dspcasvar, etc.) to confirm that the configuration has been preserved through the upgrade process.
It is also recommended that a further verification be performed by making some minor modifications to the configuration, checking that the changes have been executed correctly, and then changing the configuration back again.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Sat Jul 15 10:46:47 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.