FRSM-HS2 module sits in any of the MGX 8850 Service Module slots. The FRSM-HS2 is a high Speed frame relay service module. It provides two 52 Mbps HSSI lines and a peak throughput of 04 Mbps.
This chapter describes dialogs that show configuration information for:
Select the FRSM card to display FRSM card configuration dialogs by doing one of the following:
The FRSM-HS2 Card Category menu contains the following items:
These dialogs are described in the sections that follow.
Use the Card Configuration dialog to view FRSM-HS2 card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Figure 8-1.
| Parameter | Description |
|---|---|
Slot Number | Number of the current slot the card is installed in. |
Card Type | Current card type. In this case, it is an FRSM-HS2. |
Card State | Front card status. Can be one of the following:
|
Front Card Description | Description of the front card. |
Front Card Serial No | Serial number of the front card. |
Card Hardware Revision | Current card hardware revision. |
Card Firmware Revision | Current card firmware revision. |
MIB Version Number | MIB version number updated when any part of the MIB changes. |
Card Reset Reason | Reason for the last card reset. Can be one of the following:
|
Line Module Type | Current line module number. Can be one of the following:
|
Line Module State | Current back card state. Can be notPresent, Present, invalid. |
Line Module Description | Description of the current back card. |
Line Module Serial Number | Serial number of the current back card. |
Line Module Hardware Revision | Hardware revision of the current back card. |
Line Module Firmware Revision | Firmware revision of the current back card. |
Use the Service Module Features dialog to view service module features for the FRSM-HS2 card. (See Figure 8-2.)
The parameters are described in Table 8-1.
| Parameter | Description |
Channelized Card? | Indicates whether this card will support DS0 channels. |
Card Supports Foresight? | Indicates whether this card will support ForeSight. Can be rateControlEnabled or rateControlDisabled. |
![]() |
Note This is not a configurable dialog. The CLI commands related to this dialog are dspfeature, chanfst, and clrsmcnf commands. |
Use the FR Port Realtime Counters dialog to configure FR port Realtime counters on a FRSM-HS2 card. (See Figure 8-3.)
The FR Port Realtime Counters dialog parameters are described in Table 8-3.
| Parameter | Description |
|---|---|
Port Num | Port number. |
Rcv Port Frames | Total number of receive port frames. |
Rcv Port Bytes | Total number of receive port bytes. |
Rcv Port Frames with DE | Total number of frames received in the Ingress direction. |
Rcv Port FECNs | Total number of frames with forward explicit congestion notification (FECN) bit set in the Ingress direction. |
Rcv Port BECNs | Total number of frames with backward explicit congestion notification (BECN) bit set in the Ingress direction. |
Rcv CRC ErrFrames | Total number of frames discarded in Ingress due to cycle redundancy check (CRC) error. |
Rcv Frames DiscAlignmentErr | Total number of frames discarded in Ingress due to alignment error. |
Rcv Frames DisIllLen | Total number of frames discarded in Ingress due to alignment error. |
Rcv Frames DiscIllLen | Total number of frames discarded in Ingress due to illegal length. |
Rcv Frames Illegal Header | Total number of frames discarded in Ingress due to illegal header. |
Rcv Frames Abort | Total number of received frames aborted. |
Rcv Frames Unknown DLCI | Total number of frames received with an unknown DLCI. |
Rcv Last UnKnown DLCI | Last unknown DLCI received. |
Rcv Frames Tagged FECN | Total number of frames received that were tagged with forward explicit congestion notification (FECN) bit. |
Rcv FramesTaggedBECN | Number of frames received that were tagged with backward explicit congestion notification (BECN) bit. |
Rcv Frames Tagged DE | Total number of frames received that were tagged with discard eligible (DE) bit. |
Rcv Frames Disc Exceeded Threshold | Total number of frames discarded in Ingress due to exceeded discard eligible (DE) threshold. |
Rcv Kbps AIR | Received Average Information Rate (AIR) in Kbps. |
Rcv Buf Not Available | The total number of times the receiver is turned off. |
Xmt Port Frames | Total number of frames transmitted. |
Xmt Port Bytes | Total number of bytes transmitted. |
Xmt Port Frames FECN | Total number of frames transmitted with forward explicit congestion notification (FECN) bit already set. |
Xmt Port Frames BECN | Total number of frames transmitted with backward explicit congestion notification (BECN) bit already set. |
Xmt Port Disc ExceedQDepth | Total number of frames discarded in Egress due to exceeded queue depth. |
XmtPortBytesDiscXceedQDepth | The total number of bytes discarded in Egress due to exceeded queue depth. |
Xmt Port Frames During LMI Alarm | The total number of frames transmitted during Local Management Interface (LMI) logical port alarm. |
Xmt Port Bytes During LMI Alarm | The total number of bytes transmitted during LMI logical port alarm. |
Xmt Port Frames Abort | The total number of transmit frames aborted. |
Xmt Port Underrun | The total number of frames discarded due to overrun. |
Xmt Kbps AIR | Transmit Average Information Rate in Kbps. |
Xmt Buf Not Available | The total number of times the transmitter is turned off. |
Rcv Frames Discarded due to No Chan | The total number of frames received when no channel is set up. |
Rcv Status Inquiry | The total number of Status Inquiry messages received. |
Rcv Invalid Request | The total number of Invalid Request messages received. |
Rcv Uni Seq Mismatch | The number of times User-Network Interface (UNI) messages with sequence number mismatches were received. |
Xmt Status | The number of times Status Response messages were transmitted. |
Xmt Asynch Update | The number of times Asynchronous Status messages were transmitted. |
UNI Signalling Timeout | The number of times User-Network Interface (UNI) Status Requests were not received. |
Xmt Status Inquiry | The number of status inquiry messages transmitted. |
RCV Asynch Update | The number of times asynchronous status messages were received. |
Rcv NNI Seq Mismatch | The number of times Network-to-Network (NNI) messages with sequence number mismatches were received. |
Rcv NNI Signaling Timeout | The number of times Network-to-Network (NNI) status requests were not received. |
Rcv Frames CLLM | The total number of CLLM frames received. |
Rcv Bytes CLLM | The total number of CLLM bytes received. |
Xmt Frames CLLM | The total number of CLLM frames transmitted. |
Xmt Bytes CLLM | The total number of XMT CLLM bytes received. |
CLLM Failures | The number of times an expected CLLM message was not received. |
![]() |
Note The FR Port Realtime Counters dialog is not a configurable dialog. |
Use the LCN Partition Type dialog to configure LCN partition type on a FRSM-HS2 card. (See Figure 8-4.)
Choose one from the cardLcnPartitionType pulldown menu:
| Disables partitioning on the current card. |
| Enables controller based resource type for the current card. This means the total number of LCNs available to each controller is fixed but no reservation on each port. |
| Enables card specific resource partitioning on the current card. This means that a certain number of LCNs available on each port for each controller is reserved as specified in the port resource. |
![]() |
Note The dialog must be configured before adding any connections. Once a connection is added, this dialog cannot be changed until all of the connections are deleted. |
To modify LCN partition type, make the changes you want and click Modify.
Use the Card/Ports dialog to configure Ports on a FRSM-HS2 card. (See Figure 8-5.)
The Card/Ports dialog parameters are described in Table 8-4.
| Parameter | Description |
|---|---|
Port Num | Logical port number. |
Port Line Number | Line number. |
Port RowStatus | Enables, deletes, or modifies a port. Use the Create button to:
|
Clear Port Status? | Clears the port row status. Choose noaction or yes from the popup menu. |
Port Ds0 Speed | Port speed. Choose speed56k or speed64k from the popup menu. |
EQueue Service Ratio | Number of times queue 1 is serviced for every time queue 2 is serviced. |
Port Speed (Kbps) | Port speed in Kbps. |
Port Admin Status | Port administrative status. Choose one from the popup menu:
|
Port State | Logical port state. Can be one of the following:
|
Port Type | Port type. Choose one from the popup menu:
|
Signalling Protocol Type | Sets the signalling protoco. Choose one from the menu:
|
Async Updates | Enables asynchronous status updates. Choose disable or enable from the popup menu. |
Link Integrity Timer (Secs) | Interval in seconds for Network-to-Network Interface (NNI) to do status polling. |
Poll Verification Timer (Secs) | Interval in seconds for User-Network Interface (UNI) to expect status polling. |
Status Polling Counter | Number of User-Network Interface (UNI)/ Network-to-Network Interface (NNI) polling cycles. |
Error Threshold | User-Network Interface (UNI)/ Network-to-Network Interface (NNI) error threshold. |
Event Count | User-Network Interface (UNI)/ Network-to-Network Interface (NNI) events, always greater than the Error Threshold parameter. |
Enhanced LMI | Indicates whether or not enhanced Local Management Interface (LMI) is enabled on a logical port. Choose disable or enable from the popup menu. |
CLLM Enable | Enables CLLM. Choose disable or enable from the popup menu. |
CLLM XMT Status Timer (Milli Secs) | Interval in milliseconds for CLLM to send CLLM updates. |
Port Signalling State | Port Signalling State. Can be one of the following:
|
Port Oversubscribed | Indicates whether or not the port is oversubscribed. Can be true or false. |
Port Ingress Percent Utilization | Percentage of utilization of the port in the Ingress direction. Ranges from 0-1000. |
Port Egress Percent Utilization | Percentage of utilization of the port in the Egress direction. Ranges from 0-1000. |
There are four ways to select a line (from the front or rear view of the card) to display the appropriate line configuration dialog:
To display the configuration parameters for a HSS1 line/port, select the Category popup menu at the top of the dialog. The categories of line configuration are:
Use the Physical Line Config (HSSI) dialog to view and configure line information. (See Figure 8-6.)
The HSS1 Line Config dialog parameters are described in Table 8-5.
| Parameter | Description |
|---|---|
Line Number | Line number. |
Line Enable | Disables, enables, or modifies a line. Can be one of the following:
The default is enable. |
Line Type | Line type. Can be dte or dce. The default is dce. |
Line/Port Rate (Kbps) | Line rate. |
Line Loopback Command | Line loopback command. Can be one of the following:
|
Line Send Code | Line send code. Can be one of the following:
|
Line Loopback Code Detection | Enables detection of line loopback codes. Can be codeDetectEnabled or codeDetectDisabled. The default is codeDetectDisabled. |
To modify the parameters, make the changes you want and click Modify.
Use the Physical Line Alarm Config (HSSI) dialog to view and configure physical line alarm information. (See Figure 8-7.)
The Physical Line Alarm Config (HSSI) dialog parameters are described in Table 8-6.
| Parameter | Description |
|---|---|
Alarm Line Num | Line number of the HSSI interface. |
Lin Alarm State | Status of the line alarms. A value of zero indicates no alarms. |
Line EIA Status | Status of the HSSI lines. |
Line Severity | Used to set up the severity of an LOS or clock mismatch alarm. When an LOS or clock mismatch occurs, the FRSM-HS1 sends an alarm with the appropriate status. Can be one of the following:
|
To modify the parameters, make the changes you want and click Modify.
The port configuration dialogs are described in the sections that follow. There are four dialogs for an FRSM-HS2 port configuration:
These dialogs are described in the sections that follow.
Use the Logical Port Config dialog to view and configure logical ports on an FRSM card. (See Figure 8-8.)
The Logical Port Config dialog parameters are described in Table 8-7.
| Parameter | Description |
|---|---|
Port No. | Logical port number. |
Line No. | Line number associated with the logical port. |
Port RowStatus | Port row status. Choose add, delete, or modify. |
Port Ds0 Config Bitmap | Bitmap of DS0s for a line, used to form this logical port. Bit 0 represents DS0-1. |
Port Ds0 Speed | Port DSO speed in cells per second. |
Port Flags | Number of flags transmitted between frame relay frames. |
EQueue Service Ratio | Number of times queue 1 is serviced for every time queue 2 is serviced. |
Port Speed (kbps) | Port DSO speed in kbps. |
Port Admin Status | Port administrative status. Choose one from the popup menu:
|
Port State | Logical port state. |
portSvcStatus | Port SVC status. |
portSvcShareLcn | Indicates whether or not the LCN and VPid address spaces are shared across all the ports. |
portSvcLcnLow | Beginning of the LCN range reserved for SVCs. |
portSvcLcnHigh | End of the LCN range reserved for SVCs. |
portSvcDlciLow | Beginning of the DLCI range reserved for SVCs. |
portSvcDlciHigh | End of the DLCI range reserved for SVCs. |
Port Type | Port type. Choose one from the pop-up menu:
|
Signalling Protocol Type | Signalling protocol type. Choose one from the pop-up menu:
|
Async Updates | Enables asynchronous status updates. Choose disable or enable. |
Link Integrity Timer (Secs) | Interval in seconds for NNI to do status polling. |
Poll Verification Timer (Secs) | Interval in seconds for UNI to expect status polling. |
Status Polling Counter | Number of UNI/NNI polling cycles. |
Error Threshold | UNI/NNI error threshold. |
Event Count | UNI/NNI events, always greater than the Error Threshold parameter. |
Enhance LMI | Indicates whether or not enhanced LMI is enabled on a logical port. Choose disable or enable. |
CLLM Enable | Enables or disables CLLM. Choose disable or enable. |
CLLM Xmt Status Timer (Milli Secs) | Interval in milliseconds for CLLM to send CLLM updates. |
Port Signalling State | Port signalling state. Bit 0 = 0 LMI okay or not enabled Bit 0 = 1 LMI failed Bit 1 = 0 CLLM okay or not enabled Bit 1 = 1 CLLM failed |
Port Oversubscribed | Indicates whether or not the port is oversubscribed. Can be one of: true or false. |
Port Ingress Percent Utilization | Percentage of utilization of the port in the Ingress direction. |
Port Egress Percent Utilization | Percentage of utilization of the port in the Egress direction. |
Use the FR Port RTCs dialog to view and configure port RealTime counters on a FRSM card. (See Figure 8-9.)
The FR Port RTCs dialog parameters are described in Table 8-8.
| Parameter | Description |
|---|---|
Port Num | Logical port number. |
Rcv Port Frames | Total number of frames received in the Ingress direction. |
Rcv Port Bytes | Total number of bytes received in the Ingress direction. |
Rcv Port Frames with DE | Total number of frames with DE bit set in the Ingress direction. |
Rcv Port FECNs | Total number of frames with FCNS bit set in the Ingress direction. |
Rcv Port BECNs | Total number of frames with BECN bit set in the Ingress direction. |
Rcv CRC ErrFrames | Total number of frames discarded in Ingress due to CRC error. |
Rcv Frames DiscAlignmentErr | Total number of frames discarded in Ingress due to alignment error. |
RcvFrames DiscIllLen | Total number of frames discarded in Ingress due to illegal length. |
Rcv Frames IllegalHeader | Total number of frames discarded in Ingress due to illegal header. |
Rcv Frames Abort | Total number of received frames aborted. |
Rcv Frames Unkn DLCI | Total number of frames received with an unknown DLCI. |
Rcv Last Unkn DLCI | Last unknown DLCI received. |
Rcv Frames Tagged FECN | Total number of frames received that were tagged with FECN bit. |
Rcv Frames Tagged BECN | Total number of frames received that were tagged with BECN bit. |
Rcv Frames Tagged DE | Total number of frames received that were tagged with DE bit. |
Rcv Frames Disc Exceeded Threshold | Total number of frames discarded in Ingress due to exceeded DE threshold. |
Rcv Kbps AIR | Received Average Information Rate in Kbps. |
Rcv Buf Not Available | Total number of times the receiver is turned off. |
Xmt Port Frames | Total number of frames transmitted. |
Xmt Port Bytes | Total number of bytes transmitted. |
Xmt Port Frames FECN | Total number of frames transmitted with FECN bit already set. |
Xmt Port Frames BECN | Total number of frames transmitted with BECN bit already set. |
Xmt Port Disc. Exceed Q Depth | Total number of bytes discarded in Egress due to exceeded queue depth. |
Xmt PortBytesDiscXceedQDepth | Total number of frames discarded in Egress due to exceeded queue depth. |
Xmt Port Frames During LMI Alarm | Total number of frames transmitted during LMI logical port alarm. |
Xmt Port Bytes During LMI Alarm | Total number of bytes transmitted during LMI logical port alarm. |
Xmt Frames Abort | Total number of transmit frames aborted. |
Xmt Frames Underrun | Total number of frames discarded due to overrun. |
Xmt Kbps AIR | Transmit Average Information Rate in Kbps. |
Xmt Buf Not Available | Total number of times the transmitter is turned off. |
Rcv Frames Discarded due to No Chan | Total number of frames received when no channel is set up. |
Rcv Status Inquiry | Total number of Status Inquiry messages received. |
Rcv Invalid Request | Total number of Invalid Request messages received. |
Rcv UNI Seq. Mismatch | Number of times UNI messages with sequence number mismatches were received. |
Xmt Status | Number of times Status Response messages were transmitted. |
Xmt Async Update | Number of times Asynchronous Status messages were transmitted. |
UNI Signalling Timeout | Number of times UNI Status Requests were not received. |
XMT Status Inquiry | Number of Status Inquiry messages transmitted. |
Rcv Async Update | Number of times Asynchronous Status messages were received. |
Rcv NNI Seq. Mismatch | Number of times NNI messages with sequence number mismatches were received. |
Rcv NNI Signalling Timeout | Number of times NNI Status requests were not received. |
Use the FR Port RTCs (CLLM) dialog to view and configure CLLM port RealTime counters on a FRSM card. (See Figure 8-10.)
The FR Port RTCs (CLLM) dialog parameters are described in Table 8-8.
| Parameter | Description |
|---|---|
Rcv Frames CLLM | Number of CLLM frames received. |
Rcv Bytes CLLM | Number of CLLM bytes received. |
Xmt Frames CLLM | Number of CLLM frames transmitted. |
Xmt Bytes CLLM | Number of CLLM bytes transmitted. |
CLLM Failures | Number of times an expected CLLM message was not received. |
Use the FR Port Resource Partition dialog to view and configure port resource partitions on a FRSM card. (See Figure 8-11.)
The FR Port Resource Partition dialog parameters are described in Table 8-9.
| Parameter | Description | ||
|---|---|---|---|
frResPartPortNum | Logical port number.
| ||
frResPartCtrlrNum | Index number for the controller using this port. Can be one of the following:
| ||
frResPartRowStatus | Used to add, delete or modify the partition. | ||
frResPartDlciLow | Represents low end of reserved DLCI. | ||
frResPartDlciHigh | Represents high end of reserved DLCI. | ||
frResPartIngrPctBw | Percentage of total ingress bandwidth reserved. | ||
frResPartEgrPctBw | Percentage of total egress bandwidth reserved. |
Use the Logical Ports (Service Queue) dialog to view and configure logical ports on an FRSM card. (See Figure 8-12.)
The Logical Ports (Service Queue) dialog parameters are described in Table 8-10.
| Parameter | Description |
|---|---|
frServPortNum | The logical port number. |
portServiceQueueNo | Identifies 4 of 8 possible queues according to the service type:
Queues 5 through 8 are reserved for future use. |
portEgresQDepth | Indicates the peak Egress queue depth for the logical port. The total queue depth of all connections mapped to thsi queue should not exceed this value. The default value is 1048575 |
portEgresECNThresh | ECN threshold for the logical port. If the total queue depth of all connections mapped to this port queue exceeds this threshold, then the appropriate ECN bit (FECN in the downstream direction and BECN in the upstream direction) get set. |
portEgresDEThresh | DE threshold for the logical port. If the total queue depth of all connections mapped to this port queue exceeds this threshold, and the DE bit is set in the incoming frame, then the frame gets dropped. |
portQBwInc | Denotes the bandwidth increment for this port queue. The bandwidth increment is the percentage of the port bandwidth used by all connections mapped to a particular queue scaled by the value 16384. |
portBytesdiscxceedQueFull | Counter maintained for the number of bytes discarded due to the port queue depth exceeded. |
portBytesdiscxceedQueFullDEThresh | Counter maintained for the number of bytes discarded due to the DE threshold exceeded. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Dec 20 18:36:39 PST 1999