This chapter lists the error messages by facility. Within each facility, the messages are listed by severity levels 1 to 7, where 1 is the highest severity level and 7 is the lowest severity level. Each message is followed by an explanation and a recommended action.
This section contains the boot (BOOT) messages.
Explanation The serial port is hung (HCR is set wrong), resetting the serial device.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the Processor Switch Module (PXM) to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The serial port is hung (read interrupt disabled), resetting the serial device.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The serial port is hung (write interrupt disabled), resetting the serial device.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Cell Bus Controller (CBC) messages.
Explanation Unknown/Invalid Board Id.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The given CBC Slot is unmapped and invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation cbcIN(y/present deasserted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Physical slot not configured to Logical slot.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to write to CBD chip.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation RAM access failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Channel Statistics Module (CHS) messages.
Explanation Channel initialization failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Command Line Interface (CLI) messages.
Explanation The above command was entered by the user via CLI.
Recommended Action No action required.
Explanation CLI API Error. A call to the above function failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A telnet session was attempted by the user.
Recommended Action No action required.
Explanation Could not send Login/Logout SNMP trap for CLI session.
Recommended Action No action required.
Explanation The task with given task id could not be deleted.
Recommended Action No action required.
Explanation Problems caused by routine calls that need attention.
Recommended Action No action required.
This section contains the Card Management Mode (CMM) messages.
Explanation CMM/VSM initialization error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in receiving message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in receiving event.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown message received.
Recommended Action No action required.
Explanation Error in sending a message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in receiving messages.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The input parameter to this function was invalid.
Recommended Action No action required.
Explanation Slot number is successfully set.
Recommended Action No action required.
This section contains the Control Point Software (CNTP) messages.
Explanation Attempt to allocate a buffer using ssiFrameBufferAlloc from the control point subsystem failed the specified number of times.
Recommended Action No action required.
This section contains the Database Manager (DBM) messages.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function was invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The named parameter passed in as an argument to the named function either had a length of zero or exceeded the maximum value specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The named parameter passed in as an argument to the named function had an invalid character in the string.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function is out of the specified range of values.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function exceeded maximum value specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. An invalid parameter range was specified for the name function. The starting number plus the number to do exceeds the total number available in the specified database object.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The state for the specified database object was invalid for the named function. A call was made out of sequence or too soon to be serviced. Any previous database failures could cause this condition.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. A database update operation was attempted for the named database when the card is not active. This happened in the named function. Updates can only be done on the active card.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to get RAM data for the specified table and specified element number in the named function. The element block pointer is invalid. There is no data block available for the element.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified callback function for the specified table failed with the return code specified. The function address which failed is also specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A duplicate name was passed as an argument to the named function. That name has already been used.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The named table does not exist for the previously created named database. A table cannot be added to a previously registered database or once registration complete has been called.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The configured size of the specified database table changed from the disk config without a version change. The database version must be upgraded to support the config change or the database must be deleted first.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The named operation is not currently supported in the specified function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified table name has not been registered during the initialization of the software. The table exists in the current version of the database.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. There are no updates to be committed to the specified database even though database commit has been called.
Recommended Action No action required.
Explanation Unable to create the specified semaphore in the named function. It failed with the specified error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to take the specified semaphore for the specified database in the named function. It failed with the specified return code and error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to create the specified pipc port in the named function. It failed with the specified return code and error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to get a pipc memory buffer. It failed with the specified return code and error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to send a pipc message of the specified type to other pxm card. It failed with the specified return code and error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to allocate the specified memory buffer for the specified database in the named function. It failed with the specified error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to spawn the specified task in the named function. It failed with the specified rc and error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified PMM function call failed. It failed with the specified return code and error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to perform the specified operation to the disk db table for the specified database in the named function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to perform the specified operation to the disk db table for the specified database in the named function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to perform the specified send operation for the specified database in the named function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to perform the specified sync operation for the specified database in the named function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified operation on the version file for the specified disk database has failed in the named function. See previous event for detailed failure information and next event for error context.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified operation on the map control file for the specified disk database has failed in the named function. See previous event for detailed failure information and next event for error context.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified operation on the specified disk database table has failed in the named function. See previous event for detailed failure information and next event for error context.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to remove directory tree for the specified database in the named function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to add specified message to db list for Dbm Sync task to process. See previous event for detailed failure information.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The processing of the specified message for the specified database has failed in the named function. See previous event for detailed failure information.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The sending of the specified message for the specified database has failed in the named function. See previous event for detailed failure information.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The disk map control file in the version directory for the specified database does not contain the correct header information. The database files are corrupt or were restored to the wrong location. The disk or filesystem could also have a problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The disk flag control file in the version directory for the specified database does not match the correct version. The database files are corrupt or were restored to the wrong location. The disk or filesystem could also have a problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The disk table file in the version directory for the specified database does not contain the correct header information. The database files are corrupt or were restored to the wrong location. The disk or filesystem could also have a problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified disk table file had a corrupted element. It has been invalidated and reset to the default state. Data has been lost in the table.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified database map file for the specified table number does not contain the correct checksum information. The map control file is corrupt or were restored to the wrong location.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified disk table file has been corrupted by data being changed during a write. The commit of the update has been aborted.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified field of the message passed as a parameter to the named function was invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The request to the database manager timed out the response. No response was given in indicated interval. The Database manager could have died or is hung processing this or another request.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The window resource request to get a buffer window timed out. It was unable to get a resource count in the time specified. Window resources have been lost for the database or message were lost.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified name in the message passed as parameter to the named function was invalid. It was not found with the hashkey specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified sequence number in the message passed as parameter to the named function was invalid. The correct value is specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperrcommand from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Internal Messaging Error. The field value for the named parameter passed in as an argument to the named function was invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The communication between active and standby has been lost for the specified database name. Communication has been retried the specified number of times. Core Redundancy for the Database has been lost.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The syncing of the databases to the standby card failed. Core Redundancy cannot be established.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified filename is being reported as part of a file operation or I/O error. This event is associated with that error event from the same task.
Recommended Action No action required.
Explanation The specified operation on a database file failed with the specified error number. There could be a problem with the disk or filesystem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified operation on a database file failed with the specified error number. There could be a problem with the disk or filesystem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified operation on a database directory failed with the specified error number. There could be a problem with the disk or filesystem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Internal API Software Error. The parameter value for the named parameter passed in as an argument to the named function was invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Internal API Software Error. The parameter value for the named parameter passed in as an argument to the named function exceeded maximum value specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The named table is full. There are no more entries available to create any database ids. The database manager limit needs to be increased.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The buffer list for the named database is empty when it should not be empty. The process count semaphore indicate there should be a message to process in the list.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The disk database specified is being created for the first time on disk at the specified version.
Recommended Action No action required.
Explanation The disk database specified is being upgraded from the specified version to the specified version.
Recommended Action No action required.
Explanation The disk database specified is being downgraded to the specified version.
Recommended Action No action required.
Explanation The disk database table specified is being created for the first time on disk with the specified configuration.
Recommended Action No action required.
Explanation The syncing of the specified database on the standby card has started. This must complete before the card will go to standby state.
Recommended Action No action required.
Explanation The syncing of the specified database on the standby card is complete. This standby card can go to the standby state.
Recommended Action No action required.
Explanation The specified shelf action for the specified database has happened.
Recommended Action No action required.
This section contains the File Manager (FILM) messages.
Explanation Firmware was downloaded to the Service Module successfully.
Recommended Action No action required.
Explanation This information event indicates that PXM Firmware has been downloaded.
Recommended Action No action required.
Explanation PXM Backup Boot Code has been downloaded.
Recommended Action No action required.
Explanation Unable to create a new task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to create a message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function was invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to write file to disk.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to do intercard communication through SCM.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Firmware download failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Open API of the specified file failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Open API of the specified file passed.
Recommended Action No action required.
Explanation File read failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation File write failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Closing the specified file.
Recommended Action No action required.
Explanation Card Type doesn't match the image header.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Integrated Local Management Interface (ILMI) messages.
Explanation Unable to create message queues during initialization.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Bad SNMP version.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SNMP community string purser error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown message type received.
Recommended Action No action required.
Explanation Error during sending a message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in receiving a message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid ILMI community string.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation PDU paring function returned error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Received an invalid PDU.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in ILMI trap.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in making octet string.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error PDU building function returned error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in making Var Bind.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Clone Enterprise failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in authenticating the community string.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SNMP related error happened.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid port number in the parameter sent to this function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation ILMI PrefixTable overflow.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error during sending a message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Memory not available.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to allocate SAR buffer.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Frame transmission function returned error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error while taking a semaphore.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Installation Module (INST) messages.
Explanation Initialization error in upgrade task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Wrong event received.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in receiving messages.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in allocating a buffer.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Bad event received.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown message type received.
Recommended Action No action required.
Explanation Error in sending a message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in receiving a message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation This function received an invalid input parameter.
Recommended Action No action required.
Explanation Successful slot number update.
Recommended Action No action required.
Explanation Received a sync message from INSTALL.
Recommended Action No action required.
Explanation Timer expired notification.
Recommended Action No action required.
Explanation File read or write error.
Recommended Action No action required.
Explanation Timeout waiting for response.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation NAK message received notification.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid card message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in receiving a CLI message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in sending a CLI message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Other PXM has successfully been reset.
Recommended Action No action required.
Explanation Starting the abort of all processes.
Recommended Action No action required.
Explanation Downloading FW to a card failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Downloading Firmware notification.
Recommended Action No action required.
Explanation Downloading of Firmware is successful.
Recommended Action No action required.
Explanation Change of state notification.
Recommended Action No action required.
Explanation Change of state notification.
Recommended Action No action required.
Explanation rstupgrade command notification.
Recommended Action No action required.
Explanation Beginning of install.
Recommended Action No action required.
Explanation Notification of setting primary/secondary PXM image.
Recommended Action No action required.
Explanation install command notification.
Recommended Action No action required.
This section contains the Line Driver (LDRV) messages.
Explanation Config update function detected number of requested lines exceed the maximum number of line in the PSM.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to update the configuration data base because of the invalid DB version number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Requested function detected invalid Port number passed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The pio does not indicate a known daughter card type.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The DC identification bits are invalid for number of RCMP connection.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation System routine to download FPGA image on a card returns fail.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Back card and daughter card type are mismatched.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Line alarm has been switched to a new state. The severity can be Major, Minor or Clear.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Statistical alarm has been switched to a new state. The severity can be Major, Minor or Clear.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Plcp alarm has been switched to a new state. The severity can be Major, Minor or Clear.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Plcp alarm has been switched to a new state. The severity can be Major, Minor or Clear.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Back card or Daughter card inserted or removed Line Driver enters Fail state if BC or DC is removed Line Driver enters Standby state if both BC and DC are inserted and matched.
Recommended Action No action required.
Explanation The NOVRAM read from the card does not have a valid backcard type. The Line Driver enters Fail state until a valid back card is inserted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation RCMP reset fail for the specified Daughter card. Line Driver enters Fail state.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid CMM Message length on this receive queue. Line Driver discarded the message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation CMM requests to set an invalid card state. Line Driver discarded the message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation CMM requests an invalid message type. Line Driver discarded the message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Message from an unexpected source. Line Driver discarded the message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Message not intended for Ldrv is detected. Line Driver discarded the message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SSI receive message routine detected an error. Message is being lost.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation DC and C type did not match with the MIB config type This could happen when user is swapping different line cards. Line Driver will use default configuration.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Sonet Line number does not match with the configuration database.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid SONET Scrambling option is detected in the configuration. It has to be either enabled or disabled. Line Driver will reset config to default value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid SONET medium is detected in the configuration. Line Driver will reset config to default value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid section Trace Number is detected in the configuration. Line Driver will reset config to default value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid statSeverity/lineAlmCfg is detected in the configuration. Line Driver will reset config to default value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation dsx3LineLength not in the range of 1..255. Line Driver will reset config to default value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation dsx3RedSeverity is not in the range of detected minor..major. Line Driver will reset config to default value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation dsx3LineLength not in the range of 1..255. Line Driver will reset config to default value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to register the Line Driver data base. Ldrv task will not be able to spawn properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to register a table entry into the database. Ldrv task will not be able to spawn properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to read/update database entry because of invalid table ID. Ldrv task will not be able to spawn properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The database has information that conflicts with the current Back card type. Line Driver will reset config to default value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to read/write DSx3 PLPP register because of invalid line number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to read/write OC3 PLPP register because of invalid line number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to read/write OC12 PLPP register because of invalid line number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation External Clock impedance is invalid. Expected value is 75 or 120 Ohms.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation External Clock connector type is invalid. Expected value is RJ45 or SMB.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Inband recovered clock has invalid line number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Inband Frame Pulse Clock has invalid line number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Requested Inband Frame Pulse Clock source but configuration doesn't allow it.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to config requested clock source because clock source is unknown.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to config requested clock source because clock MUX is unknown.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Line Driver Clock source changed the current clock source selection.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An SNMP config set request is made to the clock module to switch clock.
Recommended Action No action required.
Explanation A request was made to set interface type with invalid ifType.
Recommended Action No action required.
Explanation Invalid parameters passed into function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Some of QUNI chip config parameters apply to all lines, even when a change is effected through one MIB object
Recommended Action No action required.
This section contains the Operations Administration and Management Module (OAM) messages.
Explanation OAM Task Init Success.
Recommended Action No action required.
Explanation Message receive failed.
Recommended Action No action required.
Explanation Failure in receiving a cell.
Recommended Action No action required.
This section contains the MGX Inter Process Communication (PIPC) messages.
Explanation PIPC Severe Error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the MGX Management Module (PMM) messages.
Explanation The 'default' case in a switch statement has been hit.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The 'default' case in a switch statement has been hit.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Synchronization request between requested slots failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Buffer allocation failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Message error happened during sending a response.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error happened in sending a message.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation PMM time out.
Recommended Action No action required.
Explanation Application Timer Add function failed.
Recommended Action No action required.
Explanation Card assuming Mastership.
Recommended Action No action required.
Explanation Input parameter to a function is invalid or a task reported error.
Recommended Action No action required.
Explanation API Error. This error occurs when an API of a different module, such as SSI, returns an error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to create a new task.
Recommended Action No action required.
Explanation Initialization error.
Recommended Action No action required.
Explanation Invalid state or received invalid event as an input parameter.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A peer communication between the Master and the slave happened.
Recommended Action No action required.
Explanation Error occurred while trying to go active.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Resetting either Master or the Slave.
Recommended Action No action required.
Explanation Database update failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Download or RAM update error occurred.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Redundancy status changed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation This information event indicates that the date and time is broadcast periodically to SMs and Standby PXM.
Recommended Action No action required.
Explanation This information event indicates that the Ethernet interface on Active PXM is enabled.
Recommended Action No action required.
Explanation This information event indicates that the Database is to be cleared on the Standby, whenever a new fw is downloaded and reset request from Master PXM is issued.
Recommended Action No action required.
Explanation This information event indicates that the nodename from VSI Controllers (PAR) is received by the platform.
Recommended Action No action required.
Explanation ADC Conversion error happened.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation ADC related error happened.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation ADC MidVoltage calculation error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Successfully Read Fan RPM.
Recommended Action No action required.
This section contains the Queue Engine (QE) messages.
Explanation The specified QE is unable to initialize during the refresh cycle.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified QE is unable to convert Cell Loss Threshold into Exp format.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified QE got unknown interrupt signal from the system.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified QE got error interrupt signal from the system.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Routing, Control, Monitoring, and Policing (RCMP) messages.
Explanation rpDriverInit routine failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation General Error.
Recommended Action No action required.
Explanation Error while adding connections.
Recommended Action No action required.
Explanation Static RAM read/write error occurred.
Recommended Action No action required.
This section contains the Redundancy Module (RED) messages.
Explanation AC_SEND_MSG_FAILED_ERR
Recommended Action No action required.
Explanation AC_GEN_ERR
Recommended Action No action required.
Explanation AC_INFO_ERR)
Recommended Action No action required.
Explanation AC_MEM_ERR
Recommended Action No action required.
Explanation AC_TIME_OUT_ERR
Recommended Action No action required.
Explanation AC_WRONG_MSG_ERR
Recommended Action No action required.
Explanation AC_DWNL_BRAM_ERR
Recommended Action No action required.
Explanation AC_UPLD_BRAM_ERR
Recommended Action No action required.
Explanation Message error. Data Errors and Unknown Msgs.
Recommended Action No action required.
Explanation Auto Card send message failed error.
Recommended Action No action required.
Explanation Auto Card PMM related failure / BRAM related failure.
Recommended Action No action required.
Explanation Autocard error event.
Recommended Action No action required.
Explanation Auto Card memory error.
Recommended Action No action required.
Explanation Auto Card time out error.
Recommended Action No action required.
Explanation Auto Card wrong message type error.
Recommended Action No action required.
Explanation BRAM download error.
Recommended Action No action required.
Explanation BRAM upload error.
Recommended Action No action required.
Explanation General system error.
Recommended Action No action required.
Explanation System Information.
Recommended Action No action required.
Explanation SMM bad shelf slot.
Recommended Action No action required.
This section contains the Remote File System (RFS) messages.
Explanation Unable to get buffer for communication.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to create port for communication.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to spawn task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown message received.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unsupported message received.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation RFS request dropped.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the RPM Management Module (RMM) messages.
Explanation Unable to get buffer for communication.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to create port for communication.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to create seat for communication.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to delete seat.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to spawn task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown message received.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to ack task init.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to init task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Task unable to go ACTIVE.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to wait for card ready in task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to wait for the card to go ACTIVE.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unexpected seat transport_type.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation RMM seat resync success!!
Recommended Action No action required.
Explanation Unable to resync seats.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Seat is not up.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Initialization failure : check string for details.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unexpected numeric value or return code.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unexpected string value or return code.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the RPM Virtual Task (RVT) messages.
Explanation Error occurred when RVT task tried to initialize.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An IOS IPC error occurred.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation RPM sub interface bulk update failed. There will be inconsistency between the database in RPM and PXM.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A conn resync error occurred.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Segmentation and Reassembly (SAR) messages.
Explanation DMA error has happened.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Shelf Communication Module (SCM) messages.
Explanation Error in receiving message.
Recommended Action No action required.
Explanation SPI path addition failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SCM initialization failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown message type received.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SCM SSI message send to application failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Frame bigger than the expected size received.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown cardInx value.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown frame received.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Card is in the wrong state.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation NULL pointer encountered.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SCM queue overflow.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Retransmit queue is empty.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Destination not present.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SCM frame sequence number mismatch.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SSI frame buffer allocation function returned error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error in receiving SAR buffer.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Frame transmission error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Response time out.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Debug event.
Recommended Action No action required.
This section contains the Selftest Module (SLFT) messages.
Explanation Selftest of the card failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Simple Network Management Protocol (SNMP) messages.
Explanation API Software Error. The parameter value for one of the parameters passed in as an argument to the named function was invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function was invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The named parameter passed in as an argument to the named function either had a length of zero or exceeded the maximum value specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified function call failed. It failed with the specified return code. A stack trace was generated.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified function call failed. It failed with the specified return code.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function is out of the specified range of values.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A call to allocate more memory has failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to open the IP layer transport failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to bind to the IP layer transport failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to receive a message from the IP layer failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to send a control point message failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to receive a control point message buffer failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invocation of a function using an invalid SRM slot.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to generate a trap resulted in an error. The card type of the originating slot could not be identified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid varbind was detected during processing.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to create the control point semaphore failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to take the control point semaphore failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to give the control point semaphore failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to take a control point message buffer failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to allocate a SAR Frame buffer failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempted trap generation was disallowed.
Recommended Action No action required.
Explanation An attempted trap generation was disallowed.
Recommended Action No action required.
Explanation The RTM trap log buffer has wrapped around.
Recommended Action No action required.
Explanation An attempt to close an RPM port failed because the port was already closed
Recommended Action No action required.
Explanation An attempt to open an RPM port failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to open an IPC port failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A call to process_dequeue() failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A call to create_watched_queue() failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A call to ipc_create_named_port() failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A call to ipc_get_pak_message() has failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A call to ipc_send_message() has failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A message of a given length was considered too small.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A message of a given length was considered too small.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SNMP RAM DB initialization failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SNMP RAM Table registration failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SNMP RAM Table update to the standby failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Standby RAM update failed. Invalid action requested.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Standby update has the wrong number of elements.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An SNMP request was dropped due to inadequate resources.
Recommended Action No action required.
Explanation An SNMP trap was dropped due to inadequate resources.
Recommended Action No action required.
Explanation An SNMP trap was dropped because PXM state was invalid.
Recommended Action No action required.
Explanation An attempt to generate a non-RTM SNMP trap was rejected.
Recommended Action No action required.
Explanation A message was received from an unexpected source.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Error. Error in cloning an SNMP trap.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Switch Path Interface (SPI) messages.
Explanation Switch Path related error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Card driver error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VI related error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation QB error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SDRV error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Switch Path Management (SPM) messages.
Explanation Failed to initialize shelf archive file header.
Recommended Action No action required.
Explanation Failed to initialize slot archive file.
Recommended Action No action required.
Explanation SPM database corruption.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Failed to initialize Resource RAM Database.
Recommended Action No action required.
Explanation Failed to start the timer.
Recommended Action No action required.
Explanation Failed to allocate memory.
Recommended Action No action required.
Explanation Failed to send message.
Recommended Action No action required.
Explanation General error.
Recommended Action No action required.
Explanation RM API parameter error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation NULL pointer in RM API.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the Service Resource Module (SRM) messages.
Explanation Database Table initialization error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to register the SRM TASK data base SRMCT task will not be able to spawn properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to read/update data base entry because of invalid table ID SRMCT task will not be able to spawn properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to read/update data base entry because of invalid table ID SRMCT task will not be able to spawn properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SrmComTask initialization error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Card insertion notification.
Recommended Action No action required.
Explanation Card removal notification.
Recommended Action No action required.
Explanation Successful back card detection.
Recommended Action No action required.
Explanation Unable to detect the back card.
Recommended Action No action required.
Explanation SRM card in unknown state
Recommended Action No action required.
Explanation Unknown SRM card detected.
Recommended Action No action required.
Explanation PIO initialization failure.
Recommended Action No action required.
Explanation SRM PIOs indicate that the card is not inserted properly.
Recommended Action No action required.
Explanation XIL image encountered.
Recommended Action No action required.
Explanation Function that gets XIL image failed.
Recommended Action No action required.
Explanation SRM XILINX down failed.
Recommended Action No action required.
Explanation SRM card failure message received.
Recommended Action No action required.
Explanation Invalid SRM message received.
Recommended Action No action required.
Explanation Successful SRM clear configuration.
Recommended Action No action required.
Explanation SRM configuration error.
Recommended Action No action required.
Explanation SRM CARD went in to Mismatch because this hardware revision is not supported in POPEYE
Recommended Action No action required.
Explanation Srbm error has occurred.
Recommended Action No action required.
This section contains the System Service Interface (SSI) messages.
Explanation The archive file doesn't exist on the service module.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function was invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function exceeded maximum value specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation API Software Error. The parameter value for the named parameter passed in as an argument to the named function is out of the specified range of values.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A function trace dump has been saved which contains a trace of the operations being done before the current reset. If the reset was a watchdog timeout then this information will indicate what was happening when the watchdog occurred.
Recommended Action No action required.
Explanation A software exception has occurred. The vector number specifies the type of exception. The EPC is the program counter of the failing instruction. The address field is the address that was attempted to be accessed if a load or store TLB or Address exception. See the associated error log for additional information of the exception state.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The named function was called by an interrupt service routine and it cannot perform any blocking function calls.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The VxWorks semaphore used to protect the specified system table was not able to be taken. SSI may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Creation of a Vxworks object failed due to a memory shortage in the VxWorks system memory partition.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The system semaphore table is full. There are no more entries available to create an SSI_SEMID. The system limit needs to be increased or dynamically created semaphores are not being deleted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid deadlock action value was passed in as an argument to create an SSI semaphore.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid semaphore type value was passed in as an argument to create an SSI semaphore.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid semaphore option value was passed in as an argument to create an SSI semaphore.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid semaphore initial state value was passed in as an argument to create an SSI semaphore.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Creation of a semaphore failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid SSI semaphore id was passed in as an argument into the function. The SSI_SEMID is in the incorrect format.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The SSI semaphore id that was passed in as an argument is no longer valid. The SSI_SEMID probably has been deleted.
Recommended Action No action required.
Explanation The SSI semaphore id that is being deleted is not owned by the deleting task and could be owned by another task. A mutual exclusion semaphore should be taken before deletion.
Recommended Action No action required.
Explanation The deletion of VxWorks semaphore used to implement the SSI_SEMID failed unexpectedly. Memory resources may have been lost.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The Take of VxWorks semaphore used to implement the SSI_SEMID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The SSI semaphore id that is being given is not owned by the giving task and mutual exclusion semaphore can only be given by the owning task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The Give of VxWorks semaphore used to implement the SSI_SEMID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The SSI semaphore id that is being flushed does not support the flush operation and should not be called.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The Give of VxWorks semaphore used to implement the SSI_SEMID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The system message queue table is full. There are no more entries available to create a SSI_MQID. The system limit needs to be increased or dynamically created message queues are not being deleted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid maximum number messages in the message queue was passed in as an argument to create an SSI message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid message length value was passed in as an argument to create an SSI message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid owner task id value was passed in as an argument to create an SSI message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An nonexistent owner task id value was passed in as an argument to create an SSI message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Creation of a message queue failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The creation of VxWorks semaphore used to synchronize multiple SSI_MQID message queues failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid SSI message queue id was passed in as an argument into the function. The SSI_MQID is in the incorrect format.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The SSI message queue id that was passed in as an argument is no longer valid. The SSI_MQID probably has been deleted.
Recommended Action No action required.
Explanation An invalid message queue quota value was passed in as an argument to set the quota on a SSI message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The deletion of VxWorks semaphore used to synchronize multiple SSI_MQID message queues failed unexpectedly. Memory resources may have been lost.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The deletion of VxWorks message queue used to implement the SSI_MQID failed unexpectedly. Memory resources may have been lost.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The receive on the VxWorks message queue to flush it failed unexpectedly. It could have been corrupted or deleted unexpectedly
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid message length value was passed in as an argument to send message to an SSI message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The send to VxWorks message queue used to implement the SSI_MQID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The give of VxWorks semaphore used to synchronize multiple SSI_MQID message queues failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The send to message queue was done by an Interrupt Service Routine with a non zero timeout value. ISRs cannot block.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid message length value was passed in as an argument to receive message from an SSI message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The receive from VxWorks message queue used to implement the SSI_MQID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The give of VxWorks semaphore used to synchronize multiple SSI_MQID message queues failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid message handler function pointer value was passed in as an argument to create an SSI message queue that requires a message handler.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The message handler function returned failure while processing a message received in the SSI message queue.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Getting the number of messages in the VxWorks message queue used to implement the SSI_MQID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid message info structure pointer value was passed in as an argument to get SSI message queue information.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Getting the information about the VxWorks message queue used to implement the SSI_MQID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The system task table is full. There are no more entries available to create a SSI_TID. The system limit needs to be increased or dynamically created tasks are not being deleted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The give of VxWorks semaphore used to synchronize child SSI_TID initialization status with spawning parent failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The child SSI_TID was unable to send its initialization status to the spawning parent task as the parent timed-out and is no longer waiting for the child status.
Recommended Action No action required.
Explanation The SSI_TID failed to initialize properly and was suspended to prevent further errors.
Recommended Action No action required.
Explanation An invalid SSI task id was passed in as an argument into the function. The SSI_TID is in the incorrect format.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The SSI task id that was passed in as an argument is no longer valid. The SSI_TID probably has been deleted.
Recommended Action No action required.
Explanation The deletion of VxWorks task used to implement the SSI_TID failed unexpectedly. Memory resources may have been lost.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The SSI task id that was passed in as an argument is safe from being deleted and it is also suspended. Task may have suspended on an exception after taking a task safe mutual exclusion semaphore.
Call to delete task is failed rather than cause hang condition to caller.
Recommended Action No action required.
Explanation The resumption of VxWorks task used to implement the SSI_TID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The suspension of VxWorks task used to implement the SSI_TID failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The SSI task id that was passed in as an argument is safe from being deleted. The task may be holding a mutual exclusion semaphore and should not be suspended. Suspension could result in a deadlock of the system. Suspension is failed rather than cause hang condition to system.
Recommended Action No action required.
Explanation An invalid task priority number was passed in as an argument to create an SSI task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid task priority group was passed in as an argument to create an SSI task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid task application id value was passed in as an argument to create an SSI task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid task stack size value was passed in as an argument to create an SSI task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid task suspend action value was passed in as an argument to create an SSI task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An invalid task fail action value was passed in as an argument to create an SSI task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The creation of VxWorks semaphore used to synchronize SSI_TID initialization with parent failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Spawning of a task failed unexpectedly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The parent SSI_TID timed out the send of initialization status from the child task. Either child task had problems or didn't wait long enough.
Recommended Action No action required.
Explanation The parent SSI_TID was unable to wait for the send of initialization status from the child task.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The SSI task id that is being deleted still owns message queues. These message queues should be deleted before the task is deleted if the task is not being recovered.
Recommended Action No action required.
Explanation The private partition structure which holds information about the partitions has not been allocated. This indicates a software problem (ssiMemPartInit has not been called, or the pointer has been overwritten).
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt was made to create an invalid number of partitions. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error was returned by malloc when attempting to allocate the partition info structure.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error was returned by semBCreate when attempting to create a semaphore.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt was made to allocate memory with a memory type parameter that is invalid. This indicates a software problem
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt was made to allocate memory with an options flag parameter that is invalid. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt was made to allocate 0 bytes. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt was made to allocate more memory than what is allocated for the partition.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation While attempting to get the partition statistics, memPartInfoGet returned an error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation While attempting to allocate low priority memory, the number of free bytes is below the set threshold.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error was returned by memPartAlloc while attempting to allocate memory.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A process that is not the owner of allocated memory is attempting to deallocate the memory. This indicates a software error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error was returned by memPartCreate while attempting; to create the specified partition.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error was returned by memPartFree while attempting to deallocate memory.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The memory address is not within any of the partitions. This indicates a bad address or possible corruption of the memory partition structure.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The memory type stored in the header of the block is wrong. This indicates that the header has been corrupted or is invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The magic number stored at the end of the block is wrong. This indicates that memory has been corrupted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The reference count for the block is 0. This indicates that the block has already been freed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The partition index in the header is invalid. This block was allocated from the VxWorks memory heap and this should be ab1ebeef. This indicates that the header has been corrupted or is invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The partition index in the header is invalid. This indicates that the header has been corrupted or is invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The dynamic partition does not have enough space to allocate the specified number of bytes. The software will try to allocate the space from the static partition.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The static partition does not have enough space to allocate the specified number of bytes. The software will try to allocate the space from the VxWorks heap.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The address is not within the range of the partition stored in the header. This indicates that the header has been corrupted or is invalid.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The chunk memory manager could not create the mutex semaphore necessary for its operation.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error was returned by ssiMalloc when attempting to allocate the memory for the pool.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The required memory size was not allocated for this pool. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error occurred when trying to acquire the mutex. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error occurred when trying to release the mutex. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The pool operation could not be tried because the pool is in use.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The pool ID is invalid. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified pool cannot allocate the requested chunks. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The chunk pointer is invalid. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The chunk is not allocated. This indicates a software problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The magic number stored at the end of the block is wrong. This indicates that memory has been corrupted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The memory chunk is not within the pool specified by the pool ID. This indicates that memory has been corrupted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A process that is not the owner of allocated memory is attempting to deallocate the memory. This indicates a software error.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The system timer table is full. There are no more entries available to create a SSI_TIMERID. The system limit needs to be increased or dynamically created tasks are not being deleted.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt was made to create a system timer with an invalid handler function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to create a Vx POSIX timer failed. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to create a Vx POSIX timer failed. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to cancel a Vx POSIX timer failed. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt to delete a Vx POSIX timer failed. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An SSI function was called with an invalid timer ID. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An SSI function was called for an invalid timer entry. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An SSI function was called to operate on a timer entry by a non-owning task. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An SSI function was called with an invalid timer value. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An SSI function call to either set or get the. timer value failed. SSI timers may not be initialized properly.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An SSI function call to manipulate a POSIX signal failed. This indicates corruption has occurred.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The function call to get the current time-of-day failed. This indicates corruption has occurred.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The function call to mktime to convert a broken down time to an integer second count failed with the error code specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The function call to putenv to put a variable into the environment failed with the error code specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to create the specified watchdog for the specified use in the named function. It failed with the specified error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unable to start the specified watchdog for the specified use in the named function. It failed with the specified return code and error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specfied timeout event could not be found in the named function. The value of the Timeout function and key are specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The synchronous timeout facility was not initialized for the calling task before it tried to call the specified function. Initialization must be called before calling the function.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified timeout handler function failed in the specified function. It was passed the specified key. The function failed with the specified return code and error number.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the System Module (SYS) messages.
Explanation System started after reset.
Recommended Action No action required.
Explanation Version of Backup Boot and runtime FW image.
Recommended Action No action required.
Explanation Failed to spawn task.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation System has detected a ready task.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation System has detected a task that is ready but not using the CPU.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The Root Task is suspended, because of a NAK or timeout trying to spawn the static tasks.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The Background Task is suspended, and could not restart.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The Background Task got suspended, and restart is successful.
Recommended Action No action required.
Explanation A task has disappeared or suspended, and could cause system RESET.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A task has disappeared or suspended.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A task has disappeared or suspended, and SYSTEM is not RESET
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation taskRecover(): wrong type to recover a task.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Failed to open event log file.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Error Task has received a message other than the message type of ERR_LOG_MSG.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Failed to adjust the priority for a task.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Failure to find the highest priority ready task in trGet().
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation BRAM checksum failed.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Exceptional Interrupt occurred.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Invalid card type.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation BRAM checksum failed.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Test for Dump Trace.
Recommended Action No action required.
Explanation Test for Stack Trace.
Recommended Action No action required.
Explanation Test for Stack Trace and Dump Trace.
Recommended Action No action required.
Explanation Test for BRAM and Stack Trace and Dump Trace.
Recommended Action No action required.
Explanation This information event indicates that the date or time for the shelf has been updated. The new time is the timestamp on the event while the old time is given in the message.
Recommended Action No action required.
Explanation This information event indicates that the time zone information for the shelf has been updated. The new and old time zone information is given in the message.
Recommended Action No action required.
Explanation The message received by the specified function as a parameter is invalid. The message size and contents are specified.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The processing of log messages failed the specified number of consecutive times. There is a problem with the received messages or the receiving message queue. The last time failed with the specified error number.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The following counts were accumulated for processing of log messages. The first count is the number of event messages processed. The second count is the number of error messages processed. The third count is the number of invalid messages received. The fourth count is the number of times event save has failed. The fifth count is the number of times error saving has failed.
Recommended Action No action required.
Explanation The saving of events to disk failed the specified number of consecutive times. There is a problem with saving the events to disk. The last time failed with the specified error number.
Recommended Action Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The following counts were accumulated for saving events to disk. The first count is the total number of saves that failed. The second count is the number of event file opens that failed. The third count is the number of event file creates that failed. The fourth count is the number of event file seeks that failed. The fifth count is the number of event file writes that failed. And the sixth count is the number of event file flushes that failed.
Recommended Action No action required.
Explanation The values of the registers whenever a boot of the card happens. This gives detailed information what the state of the CPU was when the reset occurred.
Recommended Action No action required.
This section contains the Trivial File Transfer Protocol (TFTP) messages.
Explanation Received error while trying to read data from TFTP socket.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
TaskStackSize: [dec]
Explanation Spawning of a task failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
This section contains the VSM Connection Management (VCNM) messages.
Explanation Initialization failure.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown message received.
Recommended Action No action required.
Explanation Event received from unknown task.
Recommended Action No action required.
This section contains the Virtual Switch Interface (VSI) messages.
Explanation VSI msg length problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI pg length problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Syntax error in parsing VSI message problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI Controller Problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI SAP problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI msg queue problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI socket problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Unknown VSI command.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI Slave trap problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI Slave transport problem.
Recommended Action No action required.
Explanation NULL pointer
Recommended Action No action required.
Explanation ssiMalloc() failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation ssiFree() failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation ssiFrameBufferAlloc() failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation ssiFrameBufferFree() failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI timer problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation VSI clock source problem.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation SSI VSI IF problem.
Recommended Action No action required.
This section contains the Virtual Service Module (VSM) messages.
Explanation Disk update failed.
Recommended Action Copy the error message exactly as it appears in the system log. Issue the dsperr command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the dsperr output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation BBIF successfully added.
Recommended Action No action required.
Explanation Deleted BBIF successfully.
Recommended Action No action required.
Explanation Modified BBIF successfully.
Recommended Action No action required.
Explanation Configuration change occurred.
Recommended Action No action required.
Explanation BB channel has been successfully added.
Recommended Action No action required.
Explanation BB channel has been successfully deleted.
Recommended Action No action required.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu Jun 17 14:29:07 PDT 1999