MGX 8850 Command Line Interface

MGX 8850 Command Line Interface

The preferred tools for configuring, monitoring, and controlling an MGX 8850 switch are the CiscoView and Cisco WAN Manager applications for equipment management and connection management, respectively. (The Cisco WAN Manager application is the former Cisco StrataView Plus application with the equipment management removed.) The command line interface (CLI) also provides access to the MGX 8850 switch and is highly applicable during initial installation, troubleshooting, and any situation where low-level control is useful.

The MGX 8850 commands in the tables that follow are divided by major functional group. Each table shows the complete name of the command and the cards for which the command is valid. For further reference, the Cisco MGX 8850 Wide Area Edge Switch Installation and Configuration document provides conceptual information on how the Cisco MGX 8850 wide area edge switch implements network services. Examples of usage for the more common commands appear in the configuration chapters of this manual.

The command line prompt shows the name of the switch, the number of the switch (which is always "1"), the slot number and type for the current card, and whether the card is in the active ("a") or standby state ("s"). The following is an example of the command line prompt:

excel.1.6.AUSM.a >
 

In this case, the current card is an active AUSM in slot 6, and the name of the node is "excel."

The command notation and argument parameters follow standard programming convention: a space separates the command and each parameter; variables have an italicized typeface; required arguments appear within "<>" marks; optional parameters appear within square brackets ("[ ]"); and a vertical bar (|) represents the logical OR function.


Note You must type all command arguments then press Return or Enter rather than enter one parameter at a time.

When you enter a command with no parameters, a usage message appears. This message shows syntax and ranges for the applicable command parameters.

The list of commands for the common equipment cards PXM and SRM appear in Table 1-1. These commands are available when you log into the PXM. The Portable AutoRoute (PAR) commands appear in Table 1-2. Applicable service module commands become available when you switch to a card by executing the cc command. The list of service module commands appear in Table 1-3. Many commands apply to both the common equipment cards and the service modules.


Table 1-1: PXM Commands
Command Description
Shelf Group

addtrapmgr

Add Trap Manager

clrcderrs

Clear Card Errors in BRAM

clrmsgcnt

Clear Control Message Counter

cnfclksrc

Configure Network Clock Source

cnfstatsmgr

Configure Statistics Manager

cnftrapmgr

Configure/Add/Delete Trap Managers

deltrapmgr

Delete Trap Manager

dspcd

Display Card

dspcderrs

Display Card Errors in BRAM

dspcds

Display Cards

dspclksrc

Display Clock Sources

dspfwrevs

Display Firmware Revisions

dspmsgcnt

Display Control Message Counter

dspsarcnts

Display SAR Counters

dspsmcnf

Display Service Module Configuration

dspstatparms

Display Statistics Alarms

dsptrapmgr

Display Trap Manager

dsptrapmgrs

Display Trap Managers

resetcd

Reset Card

switchcc

Switch Core Cards

version

Version (displays version data for a card)

User Group

adduser

Add User

cc

Change Card

clrscrn

Clear Terminal Screen

clrlog

Clear Event/Message Log

cnfpwd

Configure Password

deluser

Delete User

dsplog

Display Event/Message Log

dspusers

Display Users

Help

Help (list of commands per card)

users

Users

Node Group

cnfname

Configure Shelf Name

cnfdate

Configure Date

cnftime

Configure Time

cnftmzn

Configure Time Zone

cnftmzngmt

Configure Time Zone to GMT

cnfifip

Configure Interface IP Address

delifip

Delete Interface IP Address

dspifip

Display LAN interface IP

Redundancy Group

addred

Add Redundancy

delred

Delete Redundancy

dspfeature

Display Feature

dspred

Display Redundancy

softswitch

Soft Switch

switchback

Switch Back

Broadband Interface Group

addrscprtn

Add Resource Partition

clratmlncnt

Clear an ATM Line's Counters

clratmlncnts

Clear All ATM Line Counters

clrifcnt

Clear Counters for a Broadband Interace

clrifcnts

Clear All Counters for a Broadband Interface

cnfatmln

Configure ATM Line

cnfcdrscprtn

Configure Card Resource Partition

cnfif

Configure a Broadband Interface

cnfrscprtn

Configure Resource Partition

cnfsvclcn

Configure SVC LCNs

cnfsvcrange

Configure SVC Range

dnif

Down Interface

dspatmlncnf

Display ATM Line Configuration

dspcdrscprt

Display Card Resource Partition

dspcdrsctype

Display Card Resource Type

dspif

Display Interface

dspifcnt

Display Interface Count

dspifrsc

Display Interface Resource

dspifs

Display Interfaces

dsplnrsc

Display Line Resource

dsprscprtns

Display All Resource Partitions

dspsvcrange

Display SVC Range

upif

Up Interface

Alarm Group

clralm

Clear Line Alarms

clralmcnt

Clear Alarm Counters/Statistics

dspalm

Display Alarms for a Line

dspalms

Display All Alarms on Card

dspalmcnf

Display Alarm Threshold Configuration

dspalmcnt

Display Alarm Counters/Statistics (line)

dspshelfalm

Display Shelf Alarms

Line Group

addapsln

Add APS on a Line

addln

Add Line

delln

Delete Line

dspln

Display Line Configuration

dsplns

Display All Lines on Card

dspsrmlns

Display All Lines on Card

Channel Group

clrsarcnt

Clear SAR Counters

dspsarcnt

Display SAR Counters

dspservrate

Display Service Rate

SRM-3T3 Group

addlink

Add an SRM-3T3 T3 link to a T1slot and line

clrsrmcnf

Clear SRM-3T3 configuration

cnfsrmclksrc

Configure SRM-3T3 clock source

dellink

Delete an SRM-3T3 T3 link to a T1slot and line

delslotlnk

Delete a link from a T1 slot

dsplink

Display an SRM-3T3 T3 link to a T1slot and line

dspslotlnk

Display a link in a T1 slot

dspsrmclksrc

Display SRM-3T3 clock source

Self-Test Group

clrslftst

Clear Self-Test

dspslftsttble

Display Self-Test Table


Table 1-2:
Command Description

addtrk

Add Trunk

clrerr

Clear Error Log

cnfclksrc

Configure Clock Source

cnfcmparm

Configure Connection Manager Parameters

cnfifastrk

Configure Interface as Trunk

cnfname

Configure Node Name

cnfnwip

Configure Network IP Address

cnfswfunc

Configure Software Function

cnfsysparm

Configure System Parameters

cnftrk

Configure Trunk

deltrk

Delete Trunk

dncon

Down Connection

dspcmparm

Display Connection Manager Parameters

dspcon

Display a Connection

dspcons

Display Connections

dsperr

Display Error Log

dspload

Display Load

dspmnup

Display Mandatory Update Parameters

dspname

Display Nodename

dspnw

Display Network

dspnwcons

Display Network Connections

dspnwip

Display Network IP Address

dspswfunc

Display Software Functions

dspsysparm

Display System Parameters

dsptrkcnf

Display Trunk Configuration

dsptrkcons

Display Trunk Connections

dsptrkload

Display Trunk Load

dsptrkmcons

Display Trunk Management Connections

dsptrks

Display Trunks

uncnfifastrk

Unconfigure Interface Trunk

upcon

Up Connection

Portable AutoRoute Commands

Table 1-3:
Service Module Commands
Command Description FRSM AUSM CESM VISM CESM-T3E3
Shelf Group

clrcderrs

Clear Card Errors in BRAM

X

X

clrmsgcnt

Clear Control Message Counter

X

X

X

clrsmcnf

Clear Service Module Configuration

X

X

X

X

cnfcdrscprtn

Configure Card Resource Partition

X

X

X

cnfclksrc

Configure Network Clock Source

X

cnffst

Configure ForeSight

X

X

cnfsvcrange

Configure SVC Range

X

X

dspcd

Display Card

X

X

X

X

X

dspcderrs

Display Card Errors in BRAM

X

X

dspcdrscprtn

Display Card Resource Partition

X

X

dspclksrc

Display Clock Sources

X

dspmsgcnt

Display Control Message Counter

X

X

X

X

X

dspsmcnf

Display Service Module Configuration

X

dspstatparms

Display Statistics Parameters

X

dsptotals

Display Totals

X

X

resetcd

Reset Card

version

Version (displays card version data)

X

X

X

X

User Group

cc

Change Card

X

X

X

X

clrscrn

Clear Terminal Screen

X

X

X

X

dspmaptbl

Display Map Table

X

X

X

Help

Help (list of commands per card)

X

X

X

X

X

Alarm Group

clralm

Clear Line Alarms

X

X

X

X

X

clralmcnt

Clear Alarm Counters/Statistics

X

X

X

X

X

clralms

Clear All Alarms on the Card

X

X

X

X

X

dspalm

Display Alarms for a Line

X

X

X

X

X

dspalmcnf

Display Alarm Threshold Configuration

X

X

X

X

X

dspalmcnt

Display Alarm Counters/Statistics (line)

X

X

X

X

X

dspalms

Display All Alarms on Card

X

X

X

X

X

Line Group

addln

Add Line

X

X

X

X

X

addlnloop

Add Line Loop

X

X

X

X

cnfds3ln

Configure DS3 Line

cnfln

Configure Line

X

X

X

X

X

cnfplpp

Configure PLPP Parameters

X

delln

Delete Line

X

X

X

X

X

dellnloop

Delete Line Loop

X

X

X

X

dspds3ln

Display a DS3 Line

dspds3lns

Display DS3 Lines

dspln

Display Line Configuration

X

X

X

X

X

dsplns

Display All Lines on Card

X

X

X

X

X

Port Group

addport

Add Port

X

X

clrportcnt

Clear Port Counters

X

X

clrportcnts

Clear All Port Counters

X

X

cnfegrq

Configure Egress Queue

X

cnfilmi

Configure ILMI

X

cnfport

Configure FR Port(s)

X

X

cnfportcllm

Configure Port CLLM Parameters

X

X

cnfportq

Configure AUSM port queue

X

copyports

Copy Port Configuration

X

X

delport

Delete FRSM or AUSM Port

X

delports

Delete Port Configurations

X

X

X

dnport

Down Port

X

X

dspegrq

Display Egress Queue

dspegrqs

Display Egress Queues

dspilmi

Display ILMI

X

dspilmicnt

Display ILMI Counters

X

dspport

Display Port Configuration

X

X

dspportcnt

Display FR Port Counters

X

X

dspportq

Display Port Queue

X

dspportqs

Display Port Queues

X

dspports

Display All Ports

X

X

dspportstats

Display Port Statistics

X

upport

Up Port

X

Channel Group

addchan

Add Channel

X

X

X

X

addchanloop

Add a Channel Loopback

X

X

X

clrchancnt

Clear Channel Counter for FRSM or AUSM Channels

X

X

X

X

clrsarcnts

Clear SAR Counters

X

X

X

cnfchancaoff

Configure Channel Admission Control Off

X

clrchancnts

Clear Channel Counter for all FR Channels

X

X

X

cnfchanegressq

Configure Channel Egress Queue

X

cnfchanfst

Configure Channel ForeSight

X

X

cnfchaningressq

Configure Channel Ingress Queue

X

cnfchanmap

Configure Channel Map

X

X

X

cnfchanpol

Configure Channel Policing

X

cnfchanq

Configure Channel Queue

X

X

copychans

Copy Channel Configurations

X

X

X

delchan

Delete Channel(s)

X

X

X

X

delchanloop

Delete a Channel Loopback

X

X

X

delchans

Delete Channels

X

X

X

dspchan

Display Channel Configuration

X

X

X

X

dspchancnt

Display Channel Counters

X

X

X

X

dspchans

Display All Channels

X

X

X

dspchstats

Display Channel Statistics

X

dspsarcnt

Display SAR Counters

X

X

X

X

Connection Group

addcon

Add Connection

X

X

cnfupcabr

Configure UPC for ABR

X

cnfupccbr

Configure UPC for CBR

X

cnfupcubr

Configure UPC for UBR

X

cnfupcvbr

Configure UPC for VBR

X

delcon

Delete Connection

X

X

dspcon

Display a Connection

X

X

dspcons

Display Connections

X

X

dsploads

Display Loads

X

tstcon

Test Connection

X

X

X

X

tstconseg

Test Connection Segment

X

Self-Test Group

clrslftst

Clear Self-Test

X

X

X

X

dspslftsttble

Display Self-Test Table

X

X

X

X

IMA Group

cnfimagrp

Configure IMA Group

X

abort

The abort command aborts copying the selected firmware file into the PXM.

Full Name

Abort copying the firmware load

Syntax

abort <fw_load>

where:

fw_load

is the firmware file name. The SM card must match its name on the FW directory, (CESM=sm90.fw, FRSM=sm35.fw, AUSM=sm50.fw, FRSM-VHS=sm130.fw).

Related Commands
commit, copy, install
Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
spirit4.1.8.PXM.a > abort pxm_1.0.00Ef.fw
Description

Abort loading firmware file named pxm_1.0.00Ef.fw.

System Response

none

addapsln

The addapsln command adds APS to a line.

Full Name

Add APS to a Line

Syntax

addapsln <wSlot> <wLine> <pSlot> <pLine> <mode>

where:

wSlot

is the working slot number. Must be either 7 or 8.

wLine

is the working line number. For OC-3 the range is 1 through 4.
For OC-12: 1 is the ONLY valid number

pSlot

is the protection slot number. Must be either 7 or 8.

pLine

is the protection line number. For OC-3 the range is 1 through 4.
For OC-12: 1 is the ONLY valid number

mode

APS architect mode on the working/protection line pairs.

1: 1+1 one backcard

2: 1+1 two backcards

3: 1:1 one backcard

4: 1+1 Annex B

Related Commands
cnfapsln, delapsln, dspapsln, switchapsln
Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example
spirit4.1.8.PXM.a > addapsln 7 1 8 1 2
Description

Add APS Protection line 1 on slot 8 to APS Working line1 on slot 7. Set the APS architect mode on the working/protection line pair to 1+1.

System Response

none

addaimgrp

This command adds an AIMUX group.

Full Name

Add AIM Group

Syntax

addaimgrp <aimux_grp> <list_of_lines>

where:

aimux_grp

AIMUX group number to be added. The range is 1 through 8.

list_of_lines

list of physical lines to be included in "aimux_grp" separated by dots. The range is 1 through 8.

Related Commands

delaimgrp, cnfaimgrps, dspaimgrp, dspaimgrps

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2


Note There should not be any ATM UNI ports established with the same "port_n" since ATM ports and AIMUX groups both share the same set of port numbers.
Example
 spirit4.1.18.PXM.a > addaimgrp 2 1 3.4.5 
Description

Add IMA group 2 as UNI with lines 3, 4, and 5.

System Response

none

addcdrscprtn

The addcdrscprtn command lets you configure card-level resource partitions. This command applies only if the card partition type is controllerBased. The resource you can partition at the card level is the number of connections available to a network controller such as PAR. With card-level partitioning:

The matrix in Table 1-4 describes the effects of each of three usages of addcdrscprtn.


Table 1-4: Degrees of Card-Level Resource Partitioning
Command Description

addcdrscprtn off

Card-level partitioning is inactive. You must partition resources at the port level. The applicable CLI command is cnfportrscprtn.

addcdrscprtn on

This condition is the default for a card. Card-level partitioning is on, but no allocation for a specific controller is specified. The maximum number of connections on a port is available to each controller, so each controller competes for the connections.

addcdrscprtn on <x> <y> <z>

The x, y, and z represent a number of connections per port available to the PAR, PNNI, and Tag controllers, respectively. Note that PNNI is always 0 in the MGX 8800 Release 1.

In addition to the definitions in Table 1-4, note the following characteristics of this command:

Full Name

Add Card Resource Partition

Syntax

addcdrscprtn <PAR_max_conns> <PNNI_max_conns> <Tag_max_conns>

Related Commands

cnfcdrscprtn, dspcdrscprtn, delcdrscprtn, cnfcdrsctype

Cards on Which This Command Executes

PXM, AUSM, FRSM, CESM, VISM

Example
spirit4.1.8.PXM.a > addcdrscprtn 10000 0 10000
Description

On the current PXM, change the card-level partitioning to give 10000 GLCNs to PAR and 10000 GLCNs to Tag. Note that the value for PNNI currently is 0.

System Response

none

addchan

Add a channel to the current PXM, FRSM, or CESM. (An addchan command exists for the AUSM but has different syntax. Refer to the AUSM-specific command description.) No messages appear on-screen after you complete the command unless the command cannot execute as entered.

Full Name

Add Channel

Syntax

On PXM:

addchan <LCN> <if_num> <conn_type> <vpi> <vci> <serv_type> <y_vpi> <y_vci> <y_nsap> <chan_master>

where:

LCN

is the logical connection number in the range 16-4111.

if_num

is the number of the logical interface port. The range is 1-32. This is the interface that receives connection traffic.

conn_type

is a number representing a VPC or VCC connection type. 1=VPC (Virtual Path Connection). 2=VCC (Virtual Channel Connection).

vpi

is the VPI value. The range is 0-4095.

vci

is the VCI value. The range is 0-65535.

serv_type

is a number representing the service type:

· 1 specifies CBR, which stands for Constant Bit Rate.

· 2 specifies VBR, which stands for Variable Bit Rate.

· 3 specifies ABR, which stands for Available Bit Rate.

· 4 specifies UBR, which stands for Unspecified Bit Rate.

y_vpi

is the remote VPI value. The range is 0-4095.

y_vci

is the remote VCI value. The range is 0-65535.

y_nsap

is the remote node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

chan_master

specifies whether the local endpoint is the master or slave. 1=master. 2=slave.

Possible errors are:

On FRSM-8T1E1:

addchan <chan> <port> <dlci> <cir> <chan_type> [CAC_enable] <mastership> <locnsap> <rmtvpi> <rmtvci> <rmtnsap>

where:

chan

is a channel number in the range 16-1015.

port

is a port number in the range 1-192 for T1;
1-248 for E1.

dlci

is the DLCI in the range 0-1023.

cir

is committed information rate: 0-1536000 bps for T1;
0-2048000 bps for E1.

chan_type

is the channel type indicator with a range of 1-5:

1=NIW

2=SIW-transparent

3=SIW-translation

4=FUNI

5=frame forwarding

CAC_enable

is the optional Connection Admission Control enable, where
1=enable, 2=disable (default).

mastership

specifies whether the current end is the master or slave: 1=master, and 2=slave

locnsap

is the local node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

rmtvpi

is the remote VPI. The range is from 1 to 65535.

rmtvci

is the remote VCI. The range is from 1 to 65535.

rmtnsap

is the remote node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

Possible errors are:

On FRSM-VHS:

addchan <chan> <port> <dlci> <cir> <chan_type> <serv_type> [CAC_enable] <mastership> <locnsap> <rmtvpi> <rmtvci> <rmtnsap>

where:

chan

is a channel number in the range 16-4015.

port

is a port number in the range 1-256.

dlci

is the DLCI in the range 0-1023.

cir

is committed information rate: 0-1536000 bps for T1;
0-2048000 bps for E1.

chan_type

is the channel type indicator with a range of 1-5:

1=NIW

2=SIW-transparent

3=SIW-translation

4=FUNI

5=frame forwarding

serv_type

is a number representing the service type:

· 1 specifies CBR, which stands for Constant Bit Rate.

· 2 specifies VBR, which stands for Variable Bit Rate.

· 3 specifies ABR, which stands for Available Bit Rate.

· 4 specifies UBR, which stands for Unspecified Bit Rate.

CAC_enable

is the optional Connection Admission Control enable, where
1=enable, 2=disable (default).

mastership

specifies whether the current end is the master or slave: 1=master, and 2=slave

locnsap

is the local node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

rmtvpi

is the remote VPI. The range is from 1 to 65535.

rmtvci

is the remote VCI. The range is from 1 to 65535.

rmtnsap

is the remote node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

ON CESM-8T1E1:

addchan <chan_num> <port_num> <Ces_Cas> <partial_fill> <cond_data> <cond_sig> <mastership> <locnsap> <rmtvpi> <rmtvci> <rmtnsap>

where:

chan

is a channel number in the range 32-279.

port

is the port number. For T1, the range is 1-192. For E1, the range is 1-248.

Ces_Cas

is a number that represents the signalling selection. If type is set to 5 (CCS or Common Channel Signaling), it means that this particular channel is carrying signaling information only. All channels on a line should have the same value.

1=basic.

2=E1 CAS.

3=DS1 superframe CAS.

4=DS1 extended superframe CAS.

5=CCS

partial_fill

specifies the number of bytes to partially fill a cell for different lines:

0=a fully filled cell. This is the default.

20-47 cells for structured E1.

25-47 for structured T1.

33-47 for unstructured T1 or E1.

cond_data

specifies a data-conditioning value. For UDT, cond_data is always 255. For SDT, the range is 0-255.

cond_sig

specifies a condition signal in the range 0-15.

mastership

specifies whether the current end is the master or slave. 1=master, and 2=slave

locnsap

is the local node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

rmtvpi

is the remote VPI in the range 1-65535.

rmtvci

is the remote VCI in the range 1-65535. It should have the same value as the logical port number of the remote end point.

rmtnsap

is the remote node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

Possible errors are:

Related Commands
delchan, dspchan, dspchans

ON CESM-T3E3:

addchan <chan_num> <port_num> <cond_sig> <mastership> <locnsap> <rmtvpi> <rmtvci> <rmtnsap>

where:

chan

is a channel number, 32 for CESM-T3E3

port

is the port number. 1 for CESM-T3E3

cond_sig

specifies a condition signal in the range 0-15.

mastership

specifies whether the current end is the master or slave. 1=master, and 2=slave

locnsap

is the local node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

rmtvpi

is the remote VPI in the range 1-65535.

rmtvci

is the remote VCI in the range 1-65535. It should have the same value as the logical port number of the remote end point.

rmtnsap

is the remote node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

Possible errors are:

Related Commands

delchan, dspchan, dspchans

Cards on Which This Command Executes

PXM, FRSM, CESM

Attributes

Log: Yes State: Active Privilege: 1-2

addchan (AUSM)

Adds a channel to the current AUSM. No messages appear on-screen after you complete the command unless the command cannot execute as entered.

Full Name

Add Channel

Syntax

addchan <channel number> <connection type> <port number> <vpi> <vci> <service type> <mastership> <locnsap> <rmtvpi> <rmtvci> <rmtnsap>

where:

channel number

channel number has a range of 16-1015

connection type

connection type is either 1 for VPC (Virtual Path Connection) or 2 for VCC (Virtual Path Connection).

port number

port number is in the range 1-8

vpi

The Virtual Path Indicator (VPI) has a value in the range 0-255

vci

The Virtual Channel Indicator (VCI) has a value in the range 0-65535

service type

is a number representing the service type:

· 1 specifies CBR. (Constant Bit Rate)

· 2 specifies VBR. (Variable Bit Rate)

· 3 specifies ABR. (Available Bit Rate)

· 4 specifies UBR. (Unspecified Bit Rate)

mastership

specifies whether the current end is the master or slave. 1=master, and 2=slave

locnsap

is the local node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

rmtvpi

is the remote VPI in the range 1-65535.

rmtvci

is the remote VCI in the range 1-65535. It should have the same value as the logical port number of the remote end point.

rmtnsap

is the remote node name, slot, and port in NSAP format. This 20-byte string is the hexadecimal form of the ASCII characters.

Related Commands

delcon, dspcons, dspcon

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Any Privilege: Any

Example

spirit4.1.18.AUSM.a > addchan 16 2 1 1 1 3 1

Description

Add a VCC connection to channel 16 on port 1 with vpi=1, vci=1, ABR service type, and an egress queue number of 1

System Response

none

addchanloop

Add a channel loopback to the current FRSM, AUSM or CESM. Causes the channel to loop at the SAR (segmentation and reassembly) stage.

No messages appear on screen after command entry unless the command cannot execute as entered.

Full Name

Add a Channel Loopback

Syntax

addchanloop <chan_num>

where:

chan_num

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For PXM, 16-1024

· For AUSM, 16-1015

· For CESM-8T1/E1, 32-279

· For CESM-T3/E3, one connection starting at 32

Related Commands

delchanloop, tstcon, tstdelay

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: Yes State: Active Privilege: 1-4

addcon

Adds a connection to the current card. The addcon command is preferable to addchan for adding a connection because addcon does not require the NSAP addresses.

Command execution includes a specification of the endpoint as either the master or the slave. Execute addcon first at the slave end then the master end. The Syntax section shows the syntax for the slave and master end for each card to which this command applies. Note the syntax for the master end includes a parameter SlaveConID. Rather than a single number, SlaveConID is the node name, slot number, port number, and connection identifier (if applicable) of the slave end. No messages appear on-screen after you complete the command unless the command cannot execute as entered.


Note When you add a three-segment connection across a network, specify the PXM as slot 0.
Full Name

Add Connection

Syntax

On the FRSM-8T1/8E1:

addcon <port number> <DLCI> <CIR> <channel type> [Adm_cntrl] <controller_type> <mastership> <RemoteEndConID>

where:

port number

port number is in the range 1-192 for T1 or 1-248 for E1.

DLCI

is the DLCI in the range 0-1023.

CIR

is the committed information rate in the range 0-1536000 bps for T1; 0-2048000 bps for E1.

channel type

is a number indicating the type of connection on this channel:

1=NIW (network interworking)

2=SIW-transparent (service interworking without any SDU translation)

3=SIW-translation (service interworking with SDU translation)

4=FUNI (frame relay UNI)

5=frame forwarding.

Adm_cntrl

is the Connection Admission Control toggle, which is optional. 1 = enable CAC, 2 = disable CAC. The default is 2 (disable CAC).

controller_type

is the signalling controller type, where:

signalling controller type is either:

1 PVC (PAR), or 2 SPVC (PNNI)

The default is 1 PVC (PAR)

mastership

sets whether the connection is the master or the slave, where:

1 = master, 2 = slave

The default is 2 (slave).

RemoteEndConID

is the node name, slot number, port number, and DLCI

or

the node name, slot number, port number, Controller ID, and DLCI for a Frame Relay endpoint.

where Controller ID is either:

1 (PAR), 2 (PNNI), or 3 (TAG)

or

the node name, slot number, port number, and VPI.VCI for an ATM endpoint.

On the FRSM-2CT3:

addcon <port number> <DLCI> <CIR> <channel type> <egress service type> [Adm_cntrl] <controller_type> <mastership> <RemoteEndConID>

where:

port number

port number is in the range 1-256.

DLCI

is the DLCI in the range 0-1023.

CIR

is the committed information rate in the range 0-1536000 bps

channel type

is a number indicating the type of connection on this channel:

1=NIW (network interworking)

2=SIW-transparent (service interworking without any SDU translation)

3=SIW-translation (service interworking with SDU translation)

4=FUNI (frame relay UNI)

5=frame forwarding.

egress service type

is a number indicating the type of egress service provided on this channel:

1=highpriorityQ (typically committed bit rate connections)

2=rtVBRQ (real-time variable bit rate connections)

3=nrtVBRQ (non real-time variable bit rate connections)

4=aBRQ (available bit rate connections)

5=uBRQ (unspecified bit rate connections).

Adm_cntrl

is the Connection Admission Control toggle, which is optional. 1 = enable CAC, 2 = disable CAC. The default is 2 (disable CAC).

controller_type

is the signalling controller type, where:

signalling controller type is either:

1 PVC (PAR), or 2 SPVC (PNNI)

The default is 1 PVC (PAR)

mastership

sets whether the connection is the master or the slave, where:

1 = master, 2 = slave

The default is 2 (slave).

RemoteEndConID

is the node name, slot number, port number, and DLCI

or

the node name, slot number, port number, Controller ID, and DLCI for a Frame Relay endpoint.

where Controller ID is either:

0 (PAR), 1 (PNNI), or 2 (TAG)

or

the node name, slot number, port number, and VPI.VCI for an ATM endpoint.

On the FRSM-2T3/2E3:

addcon <port number> <DLCI> <CIR> <channel type> <egress service type> [Adm_cntrl] <controller_type> <mastership> <RemoteEndConID>

where:

port number

port number is in the range 1-2.

DLCI

is the DLCI in the range 0-1023.

CIR

is the committed information rate in the range 0-44210000 bps for 2T3, 0-34010000 bps for 2E3

channel type

is a number indicating the type of connection on this channel:

1=NIW (network interworking)

2=SIW-transparent (service interworking without any SDU translation)

3=SIW-translation (service interworking with SDU translation)

4=FUNI (frame relay UNI)

5=frame forwarding.

egress service type

is a number indicating the type of egress service provided on this channel:

1=highpriorityQ (typically committed bit rate connections)

2=rtVBRQ (real-time variable bit rate connections)

3=nrtVBRQ (non real-time variable bit rate connections)

4=aBRQ (available bit rate connections)

5=uBRQ (unspecified bit rate connections).

Adm_cntrl

is the Connection Admission Control toggle, which is optional. 1 = enable CAC, 2 = disable CAC. The default is 2 (disable CAC).

controller_type

is the signalling controller type, where:

signalling controller type is either:

1 PVC (PAR), or 2 SPVC (PNNI)

The default is 1 PVC (PAR)

mastership

sets whether the connection is the master or the slave, where:

1 = master, 2 = slave

The default is 2 (slave).

RemoteEndConID

is the node name, slot number, port number, and DLCI

or

the node name, slot number, port number, Controller ID, and DLCI for a Frame Relay endpoint.

where Controller ID is either:

0 (PAR), 1 (PNNI), or 2 (TAG)

or

the node name, slot number, port number, and VPI.VCI for an ATM endpoint.

On the FRSM-HS2:

addcon <port number> <DLCI> <CIR> <channel type> <egress service type> [Adm_cntrl] <controller_type> <mastership> <RemoteEndConID>

where:

port number

port number is in the range 1-2.

DLCI

is the DLCI in the range 0-1023.

CIR

is the committed information rate in the range 0-51840000 bps

channel type

is a number indicating the type of connection on this channel:

1=NIW (network interworking)

2=SIW-transparent (service interworking without any SDU translation)

3=SIW-translation (service interworking with SDU translation)

4=FUNI (frame relay UNI)

5=frame forwarding.

egress service type

is a number indicating the type of egress service provided on this channel:

1=highpriorityQ (typically committed bit rate connections)

2=rtVBRQ (real-time variable bit rate connections)

3=nrtVBRQ (non real-time variable bit rate connections)

4=aBRQ (available bit rate connections)

5=uBRQ (unspecified bit rate connections).

Adm_cntrl

is the Connection Admission Control toggle, which is optional. 1 = enable CAC, 2 = disable CAC. The default is 2 (disable CAC).

controller_type

is the signalling controller type, where:

signalling controller type is either:

1 PVC (PAR), or 2 SPVC (PNNI)

The default is 1 PVC (PAR)

mastership

sets whether the connection is the master or the slave, where:

1 = master, 2 = slave

The default is 2 (slave).

RemoteEndConID

is the node name, slot number, port number, and DLCI

or

the node name, slot number, port number, Controller ID, and DLCI for a Frame Relay endpoint.

where Controller ID is either:

0 (PAR), 1 (PNNI), or 2 (TAG)

or

the node name, slot number, port number, and VPI.VCI for an ATM endpoint.

On the AUSM:

addcon slave <port number> <vpi> <vci> <Conn type> <Service Type> [PAR | PNNI]

addcon master <port number> <vpi> <vci> <Conn type> <Service Type> <SlaveConID> [PAR | PNNI]

where:

slave

indicates the slave end of the connection.

master

indicates the master end of the connection.

port number

port number is in the range 1-8.

vpi

vpi has a value in the range 0-255.

vci

vci has a value in the range 0-65535.

Conn type

is the connection type. Connection Type: 0 - VCC, non zero - Local VP Id of the VPC(1 to 20(UNI)/100(STI)/340(NNI)).

Service Type

is the service type: 1=CBR, 2=VBR, and 3=ABR.

SlaveConID

is the node name, slot number, port number, vci, and vpi of the slave end. This parameter applies only at the master end.

PAR | PNNI

is the optional controller specification.

On CESM 8T1/E1:

addcon <port number> <signalling type> <partial_fill> <cond_data> <cond_signalling> <controller_type> <mastership> <RemoteEndConID>]

where:

port number

port number is in the range 1-192 for T1, 1-248 for E1.

signalling type

CAS: Channel associated signalling set to one of the following four values:

1=basic.

2=E1 CAS.

3=DS1 superframe CAS.

4=DS1 extended superframe CAS.

partial_fill

specifies the number of bytes to partially fill a cell for different lines. The value for partial fill is in the range 0-47. A partial fill value of 0 (or 47) means fully filled cells.

The lower limit for structured T1 is 25. The value for partial fill of structured T1cells is in the range 25-47.

The lower limit for structured E1 is 20. The value for partial fill of structured E1cells is in the range 20-47.

The lower limit for unstructured T1/E1 is 33. The value for partial fill of unstructured T1/E1cells is in the range 33-47.

cond_data

Conditional data is sent on the line when there is an underflow and also towards the network when forming dummy cells. For UDT, cond_data is always 255. For SDT, the range is 0-255.

cond_signalling

Conditional signalling is sent on the line when there is an underflow and also towards the network when forming dummy cells. The cond_signalling range is 0-15.

controller_type

is the signalling controller type, where:

signalling controller type is either:

1 PVC (PAR), or 2 SPVC (PNNI)

The default is 1 PVC (PAR)

mastership

sets whether the connection is the master or the slave, where:

1 = master, 2 = slave

The default is 2 (slave).

RemoteEndConID

is the node name, slot number, port number, and DLCI

or

the node name, slot number, port number, Controller ID, and DLCI for a Frame Relay endpoint.

where Controller ID is either:

0 (PAR), 1 (PNNI), or 2 (TAG)

or

the node name, slot number, port number, and VPI.VCI for an ATM endpoint.

Note: the slot number should be set to 0 (zero) to point to the active PXM.

Related Commands

delcon, dspcons, dspcon

Cards on Which This Command Executes

PXM, FRSM, CESM, AUSM

Attributes

Log: Yes State: Active Privilege: Any

Example

spirit4.1.18.AUSM.a > addcon 16 2 1 1 1 3 1

Description

Add a VCC connection to channel 16 on port 2 with vpi=1, vci=1, ABR service type, and an egress queue number of 1

System Response

none

addendpt

The addendpt command adds the endpoints on the VISM card. An endpoint is a logical port that consists of one or more DS0s. It resembles the logical port on the channelized FRSM or CESM card. The ds1_num and the ds0_list are used to create the endpoint ID. The SU requires the endpoint ID to send the Create Connection (CRCX) command of the SGCP protocol to the VISM.

Full Name

Add End Point

Syntax

addendpt <endpoint_num> <ds1_num> <ds0_list>

where:

endpoint_num

is an integer in the range 1-240.

ds1_num

is the physical line number in the range 1-8.

ds0_list

is the list of DS0s at this endpoint. The range of DS0 numbers is 1- 31 for E1 and 1-24 for T1. The DS0s on a VISM can be non-contiguous. You must separate individual DS0s by a period ("."). For the current release of the VISM, only 1 DS0 can exist on an endpoint. For multiple DS0s, you can specify a range of DS0s with a dash ("-"). For example, 1.3-5 means DS0s 1, 3, 4, and 5.

Related Commands

none

Cards on Which This Command Executes

VISM

Attributes

Log: Yes State: Active Privilege: Any

Example
spirit4.1.28.VISM.a > addendpt 1 1 1
Description

Add endpoint number 1 to physical line 1. This endpoint uses DS0 1.

System Response

none

addimagrp

This command adds an IMA group

Full Name

Add IMA Group

Syntax

addimagrp <group_num> <port_type> <list_of_links>

where:

group_num

IMA group number to be added (1-8)

port_type

Port type to be added (1-UNI, 2-NN1)

list_of_links

list of links to be included in group_num separated by dots

Related Commands

dspimagrp, dspimagrpcnt, dspimagrps, dspimainfo, dspimalncnt

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
 spirit4.1.88.AUSM.a > addimagrp 2 1 3.4.5 
Description

Add IMA group 2 as UNI with lines 3, 4, and 5.

System Response

none

addlink

The addlink command adds a link between a T1 line within a T3 line on a SRM-3T3 card and a slot and line number on a T1 service module.

Full Name

Add Link

Syntax

addlink <T3 line number> <T1 line number> <Target Slot number> <Slot line number>

where:

T3 line number

SRM-3T3 T3 line number in the format slot.line where slot can be either 15 or 31, and the port range is 1-3. Slot number 15 is used for the cards in slot and 15 and 16, whichever is active and slot 31 is used for cards in 31 and 32.

T1 line number

start T1 line number within the T3 line (range 1-28)

Target Slot number

T1 service module slot number to be linked, where Target Slot number = 1-6|9-14|17-22|25-30

Slot line number

T1 line number in the slot to be linked (range 1-4 or 1-8) depending upon the ports in the service module

Related Commands

dsplink, dellink

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
 spirit4.1.8.PXM.a > addlink 15.2 1 3 5 
Description

Add a link between the T1 line 1 within T3 line 2 on the SRM-3T3 card in slot 15 and T1 line number 5 on the T1 service module in slot 3.

System Response

none

addlmiloop

The addlmiloop command activates a line on the current card. The applicable line types are OC-12, OC-3, T3, and E3.

Full Name

Add Line

Syntax

On a service module:

addlmiloop <line number>

On a PXM:

addlmiloop -ds3 <line number> | -e3 <line number> | -sonet <line number>

where:

line number is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.
line number is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.

Note You can activate only one PXM line on the feeder implementation of an MGX 8850 node. With an OC-12 trunk, the only active port with any MGX 8850 switch implementation is Port 1.
Related Commands

dellmiloop, dsplmiloop

Cards on Which This Command Executes

FRSM, AUSM, CESM, PXM

Attributes

Log: No State: Active Privilege: 1

Example

spirit4.1.8.PXM.a > addlmiloop 1

Description

Add an LMI loopback line numbered 1 to the current card (the PXM in slot 8)

System Response

none

addln

The addln command activates a line on the current card. The applicable line types are OC-12, OC-3, T3, and E3.

Full Name

Add Line

Syntax

On a service module:

addln <line number>

On a PXM:

addln -ds3 <line number> | -e3 <line number> | -sonet <line number>

where:

line number is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.
line number is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.
line number is in the format slot.port, where slot must always be 7, and port is a value in the range 1-n, and n is the highest numbered port on the card.

Note You can activate only one PXM line on the feeder implementation of an MGX 8850 node. With an OC-12 trunk, the only active port with any MGX 8850 switch implementation is Port 1.
Related Commands

cnfln, delln, dspln

Cards on Which This Command Executes

PXM, FRSM-series, AUSM, SRM-3T3, CESM-series, VISM

Attributes

Log: No State: Active Privilege: 1 (Any on PXM)

Example

spirit4.1.8.PXM.a > addln 1

Description

Add a line numbered 1 to the current card (the PXM in slot 8)

System Response

none

On FRSM HS1:

Syntax

addln <line number> <line type> <line rate>

where:

<line number>

value from 1-2 used for HSSI, 1-4 used for X.21

<line type>

value from 1-2 where 1: DCE 2: DTE

<line rate>

value from 48kbps-52Mbps

Syntax

addln <line number> <loop type> <loop code>

where:

<line number>

value from 1-2 used for HSSI, 1-4 used for X.21

<loop type>

value from 1-4 where 1: Front-card 2: Metallic 3: Remote 4: No Loop

<line rate>

value from 1-3 where 1: LoopA/B (HSSI) 2: Local loop (X.21) 3: Unloop

addlnloop

The addlnloop command puts a line in a loopback state for the current card.

Full Name

Add Line Loop

Syntax

For a service module:

addlnloop <line number>

where:

line number

a value in the range 1-n, where n is the highest numbered port on the card.

For the PXM:

addlnloop <-ds3 | -e3 | -sonet> <line number>

where:

line number is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.
line number is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.
line number is in the format slot.port, where slot must always be 7, and port is a value in the range 1-n, and n is the highest numbered port on the card.
Related Commands

dellnloop

Cards on Which This Command Executes

PXM, AUSM, FRSM, CESM

Attributes

Log: No State: Active Privilege: Service (Any on PXM)

addlns2aimgrp

This command adds lines to an existing AIMUX group.

Full Name

Add Lines to an AIM Group

Syntax

addlns2aimgrp <aimux_grp> <list_of_lines>

where:

aimux_grp

AIMUX group to which lines should be added (1-8)

list_of_lines

list of lines in the AIMUX group separated by dots

Related Commands

dellnsfmaimgrp

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit4.1.18.AUSM.a > addlns2aimgrp 2 1.2
Description

Add lines 1 and 2 to IMA group 2.

System Response

none

addport

The addport command adds a service port to the shelf's configuration. The screen does not display a message after successful execution.

Full Name

Add a Port

Syntax for PXM OC3 back cards

addport <port_num> <line_num> <Pc_bw> <min_vpi> <max_vpi>

where:

port_num

numbers in the range 1-32 are valid

line_num

value ranging from 1 to 4 for OC3

Pc_bw

percentage of bandwidth in the range 1 - 100

min_vpi

VPI (Virtual Path Identifier) has a value in the range 0-255

max_vpi

VPI (Virtual Path Identifier) has a value in the range 0-255

Syntax for PXM OC12 back cards

addport <port_num> <line_num> <Pc_bw> <min_vpi> <max_vpi>

where:

port_num

numbers in the range 1-32 are valid

line_num

value is 1 for OC12

Pc_bw

percentage of bandwidth in the range 1 - 100

min_vpi

VPI (Virtual Path Identifier) has a value in the range 0-255

max_vpi

VPI (Virtual Path Identifier) has a value in the range 0-255

Syntax for PXM T3/E3 back cards

addport <port_num> <line_num> <Pc_bw> <min_vpi> <max_vpi>

where:

port_num

numbers in the range 1-32 are valid

line_num

value ranging from 1 to 2 for T3/E3

Pc_bw

percentage of bandwidth in the range 1 - 100

min_vpi

VPI (Virtual Path Identifier) has a value in the range 0-255

max_vpi

VPI (Virtual Path Identifier) has a value in the range 0-255

Syntax for FRSM-8T1E1 cards

addport <port_num> <line_num> <ds0_speed> <begin_slot> <num_slot> <port_type>

where:

port_num

numbers in the range 1-192 are valid for FRSM-8T1 and 1-248 for FRSM-8E1

line_num

value ranging from 1 to 8

ds0_speed

is the bit rate for the DS0. Type a "1" for 56Kbps or a "2" for 64Kbps.

begin_slot

beginning timeslot number in the T1 or E1 frame

num_slot

number of consecutive timeslots in the T1 or E1 frame

port_type

is either 1, 2, or 3: 1 = frame relay, 2 = FUNI, 3=frame forwarding

Syntax for FRSM-2T3E3 cards

addport <port_num> <line_num> <ds0_speed> <begin_slot> <num_slot> <port_type>

where:

port_num

numbers in the range 1-2 are valid for FRSM-2T3 or FRSM-2E3

line_num

value ranging from 1 to 56

ds0_speed

is the bit rate for the DS0. Type a "1" for 56Kbps or a "2" for 64Kbps.

begin_slot

beginning timeslot number in the T1 or E1 frame

num_slot

number of consecutive timeslots in the T1 or E1 frame

port_type

is either 1, 2, or 3: 1 = frame relay, 2 = FUNI, 3=frame forwarding

Syntax for FRSM-2CT3 cards

addport <port_num> <line_num> <ds0_speed> <begin_slot> <num_slot> <port_type>

where:

port_num

numbers in the range 1-256 are valid for FRSM-2CT3

line_num

value ranging from 1 to 56

ds0_speed

is the bit rate for the DS0. Type a "1" for 56Kbps or a "2" for 64Kbps.

begin_slot

beginning timeslot number in the T1 or E1 frame

num_slot

number of consecutive timeslots in the T1 or E1 frame

port_type

is either 1, 2, or 3: 1 = frame relay, 2 = FUNI, 3=frame forwarding

Syntax for FRSM-HS2 cards

addport <port_num> <line_num> <ds0_speed> <begin_slot> <num_slot> <port_type>

where:

port_num

numbers in the range 1-2 are valid for FRSM-HS2

line_num

value ranging from 1 to 56

ds0_speed

is the bit rate for the DS0. Type a "1" for 56Kbps or a "2" for 64Kbps.

begin_slot

beginning timeslot number in the T1 or E1 frame

num_slot

number of consecutive timeslots in the T1 or E1 frame

port_type

is either 1, 2, or 3: 1 = frame relay, 2 = FUNI, 3=frame forwarding

Syntax for CESM-8T1E1 cards

addport <port_num> <line_num> <ds0_speed> <begin_slot> <num_slot> <port_type>

where:

port_num

numbers in the range 1-192 are valid for CESM-8T1 and 1-248 for CESM-8E1

line_num

value ranging from 1 to 8

begin_slot

beginning timeslot number in the T1 or E1 frame

num_slot

number of consecutive timeslots in the T1 or E1 frame

port_type

is either 1, 2, or 3: 1 = structured, 2 = unstructured, 3=framing on VC disconnect

Syntax for CESM-T3E3 cards

addport <port_num> <line_num>

<where:

port_num

The only valid entry for port_num is 1 for CESM-T3E3

line_num

value is 1 for CESM-T3E3

Related Commands

addportlpbk, cnfport, delport, dspport, dspports

Cards on Which This Command Executes

PXM, FRSM, CESM

Attributes

Log: Yes State: Active Privilege: 1 (Any on PXM)

Example
node501.1.1.CESM.a > addport 1 1 1 24 1
Description

Add port 1 on line 1 with DS0 timeslots 1 through 24 assigned as structured.

System Response

none

addred

The addred command links two MGX 8850 slots (a primary slot and a secondary slot) so that the switch treats the cards in these slots as a redundant pair of cards. The secondary slot should be in the same half of the shelf (upper or lower) as the primary slot. Redundancy can be 1:1 or 1:N. If the redundancy is 1:N, you must link one secondary slot to N primary slots through multiple executions of this command.

Full Name

Add Redundancy

Syntax

addred <redPrimarySlotNum> <redSecondarySlotNum> <RedType>

where:

redPrimarySlotNum

is slot number of the slot containing the primary card of the card pair. The range is 1-6, 9-14, 17-22, and 25-30.

redSecondarySlotNum

is slot number of the slot containing the secondary card of the card pair. The range is 1-6, 9-14, 17-22, and 25-30.

RedType

is type of redundancy, where 1 = 1:1, and 2 = 1:N.

Related Commands

dspred, delred

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
node501.1.7.PXM.a > addred 1 4 1
Description

Add 1:1 redundancy between the card in slot 4 and the card in slot 1.

System Response

none

addrscprtn

The addrscprtn command specifies parameters for the resource partitions. A resource partition on a PXM consists of a percent of bandwidth, a VPI/VCI range, and the number of global logical connection numbers (GLCNs) available to a network control application. The network control applications are Portable AutoRoute (PAR) and Tag Switching. The configuration should reflect future development plans for PNNI or other controllers.


Note On a virtual trunk, the min_vpi and max_vpi should be the same. Only a routing node can support virtual trunking.
Full Name

Add Resource Partition

Syntax

addrscprtn <if_num> <ctrlr_num> <ingr_pct_bw> <egr_pct_bw> <min_vpi> <max_vpi> <min_vci> <max_vci> <max_chans>

where:

if_num

is the logical interface number in the range 1- 32.

ctrlr_num

is the number for a network control application, as follows: enter a 1 for PAR a 2 for PNNI, or a 3 for TAG.

ingr_pct_bw

is the percent of ingress bandwidth---a number in the range 0-100.

egr_pct_bw

is the percent of egress bandwidth---a number in the range 0-100.

min_vpi

is the minimum VCI Value---a number in the range 0-65535.

max_vpi

is the maximum VPI Value---a number in the range 0-4095.

min_vci

is the minimum VCI Value---a number in the range 0-65535.

max_vci

is the maximum VCI Value---a number in the range 0-65535.

max_chans

is the maximum GLCNS---a number in the range 0-32767.

Related Commands

cnfrscprtn, delrscprtn, dspifrsc, dspifs, dsprscprtns, dsprscprtn, dsplnrsc

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

addtrapmgr

This command adds an SNMP trap manager for use with stand-alone applications. A trap manager registered (added) and reregistered through the SNMP interface by Cisco WAN Manager is deregistered (deleted) after 30 minutes if it is not reregistered. Trap managers which are added using the addtrapmgr command will not age, and will not be deleted after 30 minutes.

Full Name

Add trap manager

Syntax

addtrapmgr <ipaddr> <portnum>

where:

ipaddr

The IP address assigned to the trap manager: its format is nnn.nnn.nnn.nnn., where n = 0-9 and nnn < 256.

.portnum

The port the trap manager uses to receive traps. The default is 162.

Related Commands

deltrapmgr, cnftrapmgr, dsptrapmgr, xcnftrapmgr

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example
node501.1.7.PXM.a > addtrapmgr 161.10.144.56 162
Description

Add a trap manager with the IP address of 161.10.144.56 to port 162.

System Response

none

addtrk

The PAR command addtrk activates a trunk. This command applies to only the routing node implementation. Execute addtrk after you have partitioned resources for PAR by using addrscprtn and configured the broadband interface as a trunk by using cnfifastrk.


Note Traffic class and max vpc conids should match before executing the addtrk command
Full Name

Add Trunk

Syntax

addtrk <slot.port>

where:

slot.port

The port of the trunk to activate. The variable slot is in the range 1-6, 9-14, 17-22, or 25-30, and port is a value in the range 1-n, where n is the highest numbered port on the card.

Related Commands

cnftrk, dsptrkcnf, dsptrkload, dsptrks

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 1

Example
node501.1.7.PXM.a > addtrk 1.4
Description

Activate the trunk on port 4 in the card in slot 1.

System Response

none

adduser

Add a user to the shelf configuration. The added user cannot have a privilege level that is higher than the current user. No screen output appears unless an error in the input occurred.

Full Name

Add User

Syntax

adduser <user ID> <accessLevel>

where:

user ID

name for the user. The name can be up to twelve characters. The name can consist of letters, special characters "_" and "-" and numbers. It must begin with a letter and cannot contain spaces. The name is case sensitive.

accessLevel

privilege is the highest level of access the user has. The choices are: GROUP1, GROUP2, GROUP3, GROUP4, GROUP5, or ANYUSER

Related Commands

dspusers, deluser

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 5-6

Example
spirit.1.7.PXM.a > adduser fin ANYUSER
Description

Add a user named fin with privilege level ANYUSER.

System Response
Enter password:
Re-enter password:
 
 
spirit.1.7.PXM.a >

aimhelp

Displays the Help screen for the AUSM service module.

Full Name

AIM Help

Syntax

aimhelp

Related Commands

Help

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Any state Privilege: 1-6

Example
mogul3.1.10.AUSMB8.a > aimhelp
Description

Display the Help screen for the AUSM service module.

System Response
 
AUSM-8P Commands
 
  addcon          :  Add a Connection
  addimagrp       :  Add an IMA group
  addln           :  Add a line
  addlnloop       :  Configure a line in local loopback
  addlns2imagrp   :  Add lines to an existing IMA group
  clralmcnt       :  Clear DS1 alarm count
  clralmcnts      :  Clear alarm count for all DS1 lines
  clralm          :  Clear the DS1 line alarms
  clrchancnt      :  Clear Channel Counters
  clrchancnts     :  Clear Channel Counters for all channels
  clralms         :  Clear DS1 alarms on all lines
  clrimagrpcnt    :  Clear IMA group Counters
  clrimalncnt     :  Clear IMA counters on a particular line
  clrportcnt      :  Clear Port Counters
  clrportcnts     :  Clear Port Counters for all ports
  clrsarcnt       :  Clear SAR channel counters
  clrsarcnts      :  Clear SAR counters for all channels
  clrslftst       :  Clear self test results
  clrimatst       :  clear IMA test procedure
 
Type <CR> to continue, Q<CR> to stop:
 
  cnfchanfst      :  Configure the channel foresight parameters
  cnfchanq        :  Configure the channel queue parameters
  cnffst          :  Configure foresight params of a card
  cnfportq        :  Configure Egress queue parameters
  cnfimagrp       :  Configure an IMA group
  cnfilmi         :  Configure ILMI parameters of a port
  cnfln           :  Configure DS1/E1 line
  cnflnloop       :  Configure DS1/E1 line
  cnfplpp         :  Configure DS1/E1 line
  cnfslftst       :  Configure self test parameters
  cnfsvcrange     :  Partition Resource between PVCs & SVCs
  cnfupccbr       :  Configure UPC parameters of CBR connection
  cnfupcvbr       :  Configure UPC parameters of VBR connection
  cnfupcabr       :  Configure UPC parameters of ABR connection
  cnfupcubr       :  Configure UPC parameters of UBR connection
  cnfimatst       :  Enable the IMA test procedure
  cnfimaalmparm   :  COnfigure the IMA alaram Integration UP and DOWN times
  copychans       :  Copy a template connection
  delimagrp       :  Delete an IMA group
  delcon          :  Delete a connection
  delln           :  Delete DS1 line
  dellnloop       :  Remove a DS1 line from local loopback
  dellnsfmimagrp  :  Delete lines from an existing IMA group
  dnport          :  Down an ATM port
  dspalm          :  Display DS1 alarms on a line
  dspalmcnf       :  Display DS1 alarm configuration
  dspalmcnt       :  Display alarm count for DS1 line
  dspalms         :  Display DS1 alarms on all lines
  dspcd           :  Display card information
  dspchancnt      :  Display channel counters
  dspcon          :  Display connection configuration
  dspcons         :  Display all the configured connections
  dspfeature      :  Display the features
  dspfst          :  Display the card Foresight params
  dspilmi         :  Display ILMI parms of a port
  dspilmicnt      :  Display ILMI counters of a port
  dspimagrp       :  Display all parms configured for an IMA group
  dspimagrpcnt    :  Display IMA group Counters
  dspimagrps      :  Display the configured IMA groups
  dspimalncnt     :  Display IMA counters on a particular line
  dspimatst       :  Display IMA test status
  dspimaln        :  Display IMA link status
  dspimaalmparm   :  Display IMA alaram integration times
  dspln           :  Display DS1 line
  dsplns          :  Display all DS1 lines
  dsploads        :  Display the total bandwidth used up in each port
  dspplpp         :  Display the PLPP configuration of each line
  dspport         :  Display the configured ATM/IMA port
  dspportcnt      :  Display Port Counters
  dspportq        :  Display the egress queue configuration
  dspportqs       :  Display configuration of all egress queues
  dspports        :  Display the configured ATM/IMA ports
  dspsarcnt       :  Display the SAR counters of a connection
  dspsarcnts      :  Display the SAR counters of all connections
  dspslftst       :  Display self test configuration
  dspslftsttbl    :  Display the self test results
  dspsttatparms   :  Display the statistics params configured
  dspsvcrange     :  Display the resource partition between PVCs & SVCs
  dsptotals       :  Display the total connections configured per port
  runslftstno     :  Run a particular self test
 
 
Type <CR> to continue, Q<CR> to stop:
 
  tstcon          :  Test the connection towards the N/W side
  tstconseg       :  Test the connection towards the CPE side
  tstconsti       :  Test the connection towards the N/W side using STI supervil
  tstdelay        :  Measure the delay towards the N/W side
  tstdelaysti     :  Measure the delay towards the N/W side using STI supervisol
  upport          :  Up an ATM port
  xcnfalm         :  Configure alms of a DS1 line
  xcnfln          :  Configure a DS1 line
  
spirit3.1.10.AUSMB8.a >
 
 

bye

The bye command lets you exit the current CLI shell.

Full Name

Bye

Syntax

bye

Related Commands

logout

Cards on Which This Command Executes

PXM, FRSM, AUSM, VISM

Attributes

Log: Yes State: Any Privilege: Any

Example
spirit.1.8.PXM.a > bye
Description

Exit the current CLI shell.

System Response
 
(session ended)
 
 
 

cc

Changes the card into which the user is logged. If the card slot is empty, an error message appears.

Full Name

Change Card

Syntax

cc <slot number>

where

slot number

is the card slot.

:

Related Commands

none

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: Yes State: Any state Privilege: Any

Example
node1.1.22.AUSM8.a > cc 8
Description

Switch from the AUSM in slot 22 to the PXM in slot 8.

System Response
 
 
(session redirected)
 
node1.1.8.PXM.a >
 

clraimgrpcnt

This command clears all the AIMUX related counters for all lines in the specified AIMUX group.

Full Name

Clear AIM Group Counters

Syntax

clraimgrpcnt <aimux_grp>

where:

aimux_grp

AIMUX group number in the range 1-8.

Related Commands

delaimgrpcnt

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
node1.1.22.AUSM8.a > clraimgrpcnt 8
Description

Clear all the AIM group counters in AIM group 8.

System Response

none

clraimlncnt

This command clears all the AIMUX line counters for the specified IMA group.

Full Name

Clear AIM (or Clear IMA) Line Counters

Syntax

clraimlncnt (or clrimalncnt) <aimux_grp>

where:

aimux_grp

AIMUX group number in the range 1-8

Related Commands

dspaimlncnt, clrimalncnt

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
node1.1.22.AUSM8.a > clraimlncnt 8
Description

Clear all the AIM line counters in AIM group 8.

System Response

none

clrallcnf

The clrallcnf command clears all configuration elements for all the cards in the node.


Note This command is extremely dangerous.
Full Name

Clear All Configurations

Syntax

clrallcnf

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 1-3

Example
node1.1.7.PXM.a > clrallcnf
Description

Clear all the configuration elements for all the cards in the node.

System Response

none

clralm

The clralm command clears alarms on a specified line on the current card. Alarms occurring after this command executes are not affected. If alarms on a line are cleared with this command, the results may be observable through the dspalm command.

This command can clear alarms caused only by the collection of statistical data. Alarms caused by network failure cannot be cleared. For example, an alarm caused by a collection of bipolar errors can be cleared, but an alarm caused by a card failure cannot.

Full Name

Clear Alarm

Syntax

For a PXM:

clralm -ds3 <LineNum>

where:

-ds3 LineNum

LineNum is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, where n is the highest numbered port on the card.

or

clralm -e3 <LineNum>

where:

-e3 LineNum

LineNum is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, where n is the highest numbered port on the card.

or

clralm -sonet <LineNum>

where:

-sonet LineNum

LineNum is in the format slot.port, where slot must be 7, and port is a value in the range 1-n, where n is the highest numbered port on the card.

or

clralm -plcp <PLCPNUM>

-plcp PLCPNUM

PLCPNum = 1-n, where n is the highest number line on the card.

For an FRSM, VISM, AUSM, or CESM:

clralm -ds1 <LineNum>

where:

LineNum

LineNum = 1-n, where n is the highest number line on the card.

For an SRM-3T3:

clralm <-srmds3> <LineNum>

where:

LineNum

LineNum = 1-n, where n = 3 if SRM-3T3

Related Commands

clralms, dspalm, dspalms

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: 5-6

Example
node1.1.22.AUSM8.a > clralm -ds1 1
Description

Clear all the alarms caused by the collection of statistical data for line 1 on the current card.

System Response

none

clralmcnt

The clralmcnt command clears all the alarm counters and statistics on the specified line on the current card. All counters are reset to 0. The terminal does not display a response unless an error exists in the syntax.

Full Name

Clear Alarm Counters

Syntax

For a PXM:

clralmcnt -ds3 <LineNum>

where:

-ds3 LineNum

LineNum is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, where n is the highest numbered port on the card.

or

clralmcnt -e3 <LineNum>

where:

-e3 LineNum

LineNum is in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, where n is the highest numbered port on the card.

or

clralmcnt -sonet <LineNum>

where:

-sonet LineNum

LineNum is in the format slot.port, where slot must be 7, and port is a value in the range 1-n, where n is the highest numbered port on the card.

or

clralmcnt -plcp <PLCPNUM>

where:

-plcp PLCPNUM

PLCPNum = 1-n, where n is the highest number line on the card.

For an FRSM, VISM, AUSM, or CESM:

clralmcnt -ds1 <LineNum>

where:

LineNum

LineNum = 1-n, where n is the highest number line on the card.

Related Commands

dspalmcnt, clralmcnts

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any (5 on PXM)

Example
node1.1.22.AUSM8.a > clralmcnt -ds1 1
Description

Clear all the alarm counters and statistics collected for line 1 on the current card.

System Response

none

clralmcnts

The clralmcnts command clears all the alarm counters and statistics on the current card. All counters are reset to 0. The terminal does not display a response unless an error exists in the syntax.

Full Name

Clear All Alarm Counters/statistics on the Current Card.

Syntax

clralmcnts

Related Commands

dspalmcnt, clralmcnt

Cards on Which This Command Executes

FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: 1-5

Example
node1.1.22.AUSM8.a > clralmcnts
Description

Clear all the alarm counters and statistics collected for the current card.

System Response

none

clralms

The clralms command clears alarms on the current card. Alarms occurring after this command executes are not affected.

This command can clear alarms caused only by the collection of statistical data. Alarms caused by network failure cannot be cleared. For example, an alarm caused by a collection of bipolar errors can be cleared, but an alarm caused by a card failure cannot.

Full Name

Clear Alarms on Card

Syntax

For an FRSM, VISM, AUSM, or CESM:

clralms -ds1 <LineNum>

where:

LineNum

LineNum = 1-n, where n is the highest number line on the card.

Related Commands

clralm, dspalm, dspalms

Cards on Which This Command Executes

FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: 1-5

Example
node1.1.22.AUSM8.a > clralms -ds1 1
Description

Clear all the alarms triggered by the collection of statistics for line 1 on the current card.

System Response

none

clratmlncnt

The clratmlncnt clears the ATM event counters for the specified line on the PXM.

Full Name

Clear All ATM Line Counters on the specified Line Number

Syntax

clratmlncnt <LineNum >

where LineNum is the line number in the range 1-n, where n is the highest numbered line on the card.

Related Commands

clratmlncnts

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
node1.1.7.PXM.a > clratmlncnt 1
Description

Clear all the ATM event counters for line 1 on the PXM.

System Response

none

clratmlncnts

The clratmlncnts commands clears all the ATM counters on all the lines on the current card.

Full Name

Clear all ATM Line Counters on All Lines

Syntax

clratmlncnts

Related Commands

clratmlncnt

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
node1.1.7.PXM.a > clratmlncnts
Description

Clear all the ATM event counters on the PXM.

System Response

none

clrcderrs

The clrcderrs command clears all card-related errors in an MGX 8850 card. No response messages appear on screen. Refer to the dspcderrs description to see an example of the errors that this command clears, or execute the dspcderrs command before and after executing the clrcderrs command.

Full Name

Clear Hardware/reset Errors in BRAM

Syntax

clrcderrs

Related Commands

dspcderrs

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: No State: Any Privilege: SuperUser

Example
node1.1.4.FRSM.a > clrcderrs
Description

Clear all the card-related errors on the FRSM in slot 4.

System Response

none

clrchancnt

This command clears the channel counters for the specified channel on the current card (can be an FRSM, a CESM, or an AUSM). Counting resumes after the command executes.

Full Name

Clear Channel Counters on a specified channel

Syntax

clrchancnt <channel number>

where:

channel number

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For PXM, 16-4111

· For AUSM, 16-1015

· For CESM-8T1/E1, 32-279

· For CESM-T3/E3, one connection starting at 32

Related Commands

dspchan, clrchancnts, dspchancnt

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: Yes State: Any Privilege: Any

Example
node1.1.4.FRSM.a > clrchancnt 16
Description

Clear all the channel counters for channel 16 on the FRSM in slot 4.

System Response

none

The frame relay counters for each channel are:

clrchancnts

The clrchancnts command clears all the channel counters for all channels on the current service module (can be an FRSM, an AUSM, or a CESM service module). The counters resume accruing after the command executes. For a list of the frame relay counters, refer to the description of clrchancnt.

Full Name

Clear all Channel Counters on the Card

Syntax

clrchancnts

Related Commands

dspchan, clrchancnt, dspchancnt

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: Yes State: Any Privilege: 1-3 (Any on PXM)

Example
node1.1.4.FRSM.a > clrchancnts
Description

Clear all the channel counters for all channels on the FRSM in slot 4.

System Response

none

clrconcnt

This command clears the counters for the specified Connection Identifier on the current card (must be a PXM). Counting resumes after the command executes.

Full Name

Clear Connection Counters for a specified Connection Identifier

Syntax

clrconcnt conn_ID

where:

conn_ID

A string in the format:

PortNum.VPI.VCI

where:

PortNum = 1-n, where n is the highest numbered port on the card.

VPI = virtual path identifier in the range 0-255 for UNI or 0-4095 for NNI.
Typically, the UNI applies to a line connecting a stand-alone node to a workstation.

VCI = virtual circuit identifier in the range 0-65535

Related Commands

dspcon, clrconcnts, dspconcnt, dspconcnts

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Any Privilege: Any

Example
node4.1.8.PXM.a > clrconcnt 1.2.2
Description

Clear all the counters for the connection on port 1 with a VPI of 2 and a VCI of 2.

System Response

none

clrconcnts

This command clears the counters for all the connections on the current card (must be a PXM). Counting resumes after the command executes.

Full Name

Clear Connection Counters for All Connections on the Card

Syntax

clrconcnts

Related Commands

dspcon, clrconcnt, dspconcnt, dspconcnts

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Any Privilege: Any

Example
node4.1.8.PXM.a > clrconcnts
Description

Clear all the counters for all the connections on the PXM card.

System Response

none

clrerr

The clrerr command removes all error log files or optionally removes a specific error log file if you include the -en argument and a slot number. This command is a card-level command.

Syntax:

clrerr [-en <error slot>]

where:

-en

is the optional argument that precedes a specific log file number.

error slot

is the number of the log file to clear and is identical to the slot number of the card. If you type the -en argument, a slot number is mandatory.

Related Commands

dsperr

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

wilco.1.7.PXM.a > clrerr

Description

Clear all error log files on the PXM card.

System Response

none

clrifcnt

The clrifcnt command clears the counters for a specified broadband interface.

Full Name

Clear Interface Counters for the specified interface

Syntax

clrifcnt <if_num>

where:

if_num

is the interface number in the range 1-32.

Related Commands

clrifcnts

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

wilco.1.7.PXM.a > clrifcnt 1

Description

Clear the counters for the specified broadband interface (1).

System Response

none

clrifcnts

The clrifcnts command clears the counters for all the broadband interfaces.

Full Name

Clear All Interface Counters

Syntax

clrifcnts

Related Commands

clrifcnt

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

wilco.1.7.PXM.a > clrifcnts

Description

Clear the counters for all broadband interfaces on the PXM card.

System Response

none

clrimagrpcnt

This command clears IMA (inverse multiplexing ATM) group counters on the current AUSM card for the specified IMA group.

Full Name

Clear Inverse Multiplexing ATM Group Counters

Syntax

clrimagrpcnt (or clraimgrpcnt) <imagroup>

where:

imagroup

IMA group number in the range 1-8.

Related Commands

dspimagrp, dspimagrpcnt, dspimagrps, dspimainfo, dspimalncnt

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
flyers01.1.17.AUSM.a > clrimagrpcnt 1
Description

Clear all the inverse multiplexing ATM group counters for IMA group 1 on the AUSM card in slot 17.

System Response

none

clrimalncnt

This command clears all the AIMUX line counters for the specified line in an IMA trunk.

Full Name

Clear AIM (or Clear IMA) Line Counters

Syntax

clrimalncnt (or clraimlncnt) <aimux_grp>

where:

aimux_grp

AIMUX group number

Related Commands

dspaimlncnt, clraimlncnt

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
flyers01.1.17.AUSM.a > clrimalncnt 1
Description

Clear all the inverse multiplexing ATM line counters for IMA group 1 on the AUSM card in slot 17.

System Response

none

clrlmistats

The clrlmistats command clears the LMI (Local Management Interface) related statistics on the current card.

Full Name

Clear All LMI Statistics

Syntax

clrlmistats

Related Commands

dsplmistats

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

wilco.1.7.PXM.a > clrlmistats

Description

Clear the LMI statistics on the PXM card.

System Response

none

clrlog

The clrlog command clears all event log files or the log file specified with option <-log>. The log resumes accumulating event log messages after the command executes.

Full Name

Clear Log

Syntax

clrlog [-log <log slot>]

where:

-log

indicates that a specific log file number follows.

log slot

is the number in the event log file.

Related Commands

dsplog

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Any Privilege: 1

Example

wilco.1.7.PXM.a > clrlog

Description

Clear all event log files on the PXM card.

System Response

none

clrmsgcnt

The clrmsgcnt command clears the control message counters. The control message counters are for the total numbers of:

This message also clears the control cell header received on the last unknown channel.

Full Name

Clear Control Message Counters

Syntax

clrmsgcnt

Related Commands

dspmsgcnt

Cards on Which This Command Executes

FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: 1-5

Example
flyers01.1.17.AUSM.a > clrmsgcnt 1
Description

Clear all the control message counters on the AUSM card in slot 17.

System Response

none

clrportcnt

The clrportcnt command is used to clear the values of a port's counter on the current PXM, AUSM or FRSM.

No message appears upon successful execution of the command.

Full Name

Clear Port Counters

Syntax

clrportcnt <port number>

where:

On a PXM, port number is in the range 1-32.

On an AUSM, port number is in the range 1-8.

On an FRSM, port number is in the range 1-192 for T1, 1-248 for T1.

Related Commands

clrportcnts, dspportcnt

Cards on Which This Command Executes

PXM, FRSM, AUSM

Attributes

Log: No State: Any Privilege: 1-5 (Any on PXM)

Example
flyers01.1.17.AUSM.a > clrportcnt 1
Description

Clear all the port counters on port 1 on the AUSM card in slot 17.

System Response

none

clrportcnts

The clrportcnts command clears all port counters on the current PXM, FRSM or AUSM.

No messages appear on screen after command entry unless the command cannot execute as entered.

Full Name

Clear Port Counts

Syntax

clrportcnts

Related Commands

clrportcnt, dspportcnt

Cards on Which This Command Executes

PXM, FRSM, AUSM

Attributes

Log: No State: Any Privilege: 1-5

Example
flyers01.1.17.AUSM.a > clrportcnts
Description

Clear all the port counters on all the ports on the AUSM card in slot 17.

System Response

none

clrsarcnt

The clrsarcnt command clears the Segmentation and Reassembly (SAR) counters on the current card. The SAR counters are:

Full Name

Clear SAR Counters

Syntax

clrsarcnt

Related Commands

dspsarcnt

Cards on Which This Command Executes

FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: 1-5

Example
flyers01.1.17.AUSM.a > clrsarcnt
Description

Clear all the SAR counters on the AUSM card in slot 17.

System Response

none

clrsarcnts

The clrsarcnts command clears all the SAR counters on all applicable cards.

Full Name

Clear SAR Counts

Syntax

clrsarcnts

Related Commands

clrsarcnt, dspsarcnt, dspsarcnts

Cards on Which This Command Executes

FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any user

Example
flyers01.1.17.AUSM.a > clrsarcnts
Description

Clear all the SAR counters on all the cards in the node.

System Response

none

clrscrn

The clrscrn command clears the control terminal screen. After this command executes, only the current command line prompt appears on the screen.

Full Name

Clear Terminal Screen

Syntax

clrscrn

Related Commands

none

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example
flyers01.1.17.AUSM.a > clrscrn
Description

Clear the screen.

System Response

flyers01.1.17.AUSM.a >

clrslftst

The clrslftst command clears the results of the last self test on the current card.

Full Name

Clear Self Test

Syntax

clrslftst

Related Commands

cnfslftst, dspslftst, runslftstno

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: Any user

Example
flyers01.1.17.AUSM.a > clrslftst
Description

Clear the results of the last self test for the AUSM card in slot 17.

System Response

none

clrsmcnf

The clrsmcnf command clears configuration elements for the selected service module. You must specify a slot number in the range 1-6, 9-14, 17-22, or 25-30. The elements that clrsmcnf clears are:


Note Before executing the clrsmcnf command, clear/delete all lines, ports and channels on the affected service module(s).
Full Name

Clear Service Module Configuration

Syntax

clrsmcnf <slot number>

where:

slot number

is a number in the range 1-6, 9-14, 17-22, or 25-30.

Related Commands

dspsmcnf

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 3

Example
flyers01.1.7.PXM.a > clrsmcnf 17
Description

Clear all the configuration elements on the AUSM card in slot 17.

System Response

none

clrsrmcnf

The clrsrmcnf command clears the SRM-3T3 card information and removes all T1 link mappings. All links are switched back to their respective service modules.

Full Name

Clear SRM-3T3 Configuration

Syntax

clrsrmcnf <slot number>

where:

slot number

is either 15 or 31. Slot number 15 is used for the cards in slot 15 or 16, whichever is active and slot 31 is used for cards in slots 31 and 32.

Related Commands
addlink, dsplink, xcnfsrmlink, xdspsrmlink
Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: Any

Example
flyers01.1.7.PXM.a > clrsrmcnf 15
Description

Clear all the configuration information and remove all T1 link mappings on the SRM-3T3 card in slot 15.

System Response

none

cmdhistory

The cmdhistory command displays the last 10 commands executed on the current card.

Full Name

Display Command History

Syntax

cmdhistory

Related Commands

history

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > cmdhistory
Description

Display the last 10 commands executed on the PXM card.

System Response
Size of cmdHistory is currently 10 line(s)
  1 dspconcnt 2.39.45
  2 dsplmistats
  3 dsplmiloop
  4 dsplm
  5 clrportcnt
  6 dspportcnts
  7 dspportcnt
  8 dspportcnt 1
  9 dsplmistats
 10 cmdhistory
 

cnfaimgrp

This command configures the parameters of an AIMUX group.

Full Name

Configure AIM Group

Syntax

cnfaimgrp <aimux_grp> -rwdiff <read_wr_ptr_diff> -severity <link_loss_severity> -maxdiff <maximum_diff_delay> -red <num_red_links>

where:

aimux_grp

AIMUX group number for this group (1-8)

read_wr_ptr_diff

difference between the read and write pointer maintained (1-8)

link_loss_severity

seriousness of a single link failure (1: m)

maximum_diff_delay

maximum tolerable differential delay

num_red_links

number of redundant links in the AIMUX group

Related Commands

addaimgrp, delaimgrp, dspaimgrp, dspaimgrps

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2


Note Redundant link(s) indicates the number of link(s) the system can lose without bringing down the AIMUX group. However, the <link_loss_severity> option overrides this feature.

The <read_wr_ptr_diff> value cannot be decreased from its existing value---it can only be increased (this is because decreasing the <read_wr_ptr_diff> in an established AIMUX group involves dropping cells that are stored in the delay compensation buffer.
Example
flyers01.1.17.AUSM.a > cnfaimgrp 1 -rwdiff 5 -severity 2 -maxdiff 3 -red 2
Description

Configure AIMUX group 1 on the AUSM card in slot 17 to have a read/write pointer differential of 5, a link loss severity of 2, a maximum tolerable differential delay of 5, and 2 redundant links.

System Response

none

cnfapsln

The cnfapsln command lets you specify APS parameters for a line.

Full Name

Configure APS Line

Syntax

cnfapsln <line> <SFBER> <SDBER> <WTR> <Direction> <Revertive> <K1K2>

where:

line

is the working line number. For OC-3 the range is 1 through 4.
For OC-12: 1 is the ONLY valid number

SFBER

is the signal failure BER threshold. The range is 3 to 13. If SFBER is set to 5, it means that the signal failure BER threshold = 10 ^^ -5.

SDBER

is the signal degrade BER threshold. The range is 5 to 13. If SDBER is set to 5, it means that the signal degrade BER threshold = 10 ^^ -5.

WTR

This is the amount of time (in minutes) to wait before attempting to switch back to the working line. The range is 0 to 12. It is not applicable if the line is configured in non-revertive mode (Revertive set to 1).

Direction

configures the switching direction that this APS line supports. Unidirectional means that this APS line supports only one direction. Bidirectional means that this APS line supports both ends of the line. 0: unidirectional 1: bidirectional

Revertive

used to configure the APS revertive or non-revertive option. Setting Revertive to enable allows the line to switch back to the working line after the Wait-To-restore interval has expired and the working line SF/SD has been cleared. 1: non-revertive; 2: revertive.

K1K2

enables or disables the K1/K2 inband interface on the protection line. 1: enable; 2: disable.

Related Commands

addapsln, delapsln, dspapsln, switchapsln

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example
flyers01.1.7.PXM.a > cnfapsln 1 5 5 1 2 1 0
Description

Configure the APS working line 1 on the active PXM card in slot 7 to have a signal failure BER threshold of 10^^5, a signal degrade BER threshold of 10^^5, to enable switch back after signal failure or degradation has cleared, to wait 2 minutes before attempting to switch back, to make switching bidirectional, and to enable the K1/K2 inband interface on the protection line.

System Response

none

cnfatmln

The cnfatmln command lets you specify a cell header type for a PXM trunk. The types are UNI and NNI. This command applies to a PXM in an MGX 8850 stand-alone node. The default is NNI. The typical use for UNI cell headers would be for a line that connects to a workstation rather than a switch. You must configure the cell header type using the cnfatmln command before adding lines and ports.

Full Name

Configure ATM Line

Syntax

cnfatmln <line_num> <type>

where:

line_num

is the line number. For OC-3 the range is 1 through 4, For OC-12 1 is the ONLY valid number.

type

is either 2 for UNI or 3 for NNI (the default).

Related Commands

dspatmlncnf, clratmlncnt

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
flyers01.1.7.PXM.a > cnfatmln 1 3
Description

Set the cell header type for trunk 1 on the PXM to NNI.

System Response

none

cnfcdprtntype

The cnfcdprtntype command configures the type of partition that serves as the basis for sharing GLCNs. The GLCNs are shared by the network controller applications (PAR, for example) on a logical broadband interface.

Full Name

Configure Card Resource Type

Syntax

cnfcdprtntype <prtn_type>

where:

prtn_type

Card Partition Type---a number in the range 1-3, where:

· 1 specifies noPartition. This means that all controllers compete for the total number of (G)LCNs available for the card

· 2 specifies controllerBased. This means that the total number of (G)LCNs available to each controller is fixed but there is no reservation on each port.

· 3 specifies portControllerBased. This means that a certain number of (G)LCNs available on each port for each controller are reserved

Related Commands

cnfrscprt, cnfcdrscprtn, dspcdrsctype

Cards on Which This Command Executes

PXM, AUSM, FRSM, CESM

Attributes

Log: No State: Any Privilege: Any

Example
spirit3.1.10.AUSMB8.a > cnfcdprtntype 1
Description

Allow all controllers access to all the (G)LCNs available for the card.

System Response

none

cnfcdrscprtn

The cnfcdrscprtn command lets you modify card-level resource partitions on the current card. The resource you can partition at the card level is the number of connections available to a network controller such as PNNI or Tag. With card-level partitioning:

The matrix in Table 1-5 describes the effects of each of three usages of cnfcdrscprtn.


Table 1-5: Degrees of Card-Level Resource Partitioning
Command Description

cnfcdrscprtn off

Card-level partitioning is inactive. If you specify that card-level partitioning is off (cnfcdrscprtn off), you must configure port-level partitions. The CLI command is cnfportrscprtn.

cnfcdrscprtn on

This condition is the default for a card. Card-level partitioning is on, but no allocation for a specific controller is specified. The maximum number of connections on a port is available to each controller, so each controller competes for the connections.

cnfcdrscprtn on <x> <y> <z>

The x, y, and z represent a number of connections per port available to the PAR, PNNI, and Tag controllers, respectively. Note that PNNI is always 0 in Release 1 of the MGX 8850.

Additional characteristics of this command are:

Full Name

Configure Card Resource Partition

Syntax

cnfcdrscprtn <PAR_max_conns> <PNNI_max_conns> <Tag_max_conns>

where:

PAR_max_conns

PNNI_max_conns
(currently can be only 0)

Tag_max_conns

is the maximum number of connections for the current card by controller,
as follows:

PXM, 0-32,767 GLCNs

AUSM, 1-1000

FRSM, 1-4000

CESM, 1-1000

SRM, 1-1000

Related Commands

addcdrscprtn, delcdrscprtn, dspcdrscprtn, dspcdrsctype

Cards on Which This Command Executes

PXM, AUSM, FRSM, CESM, VISM

Attributes

Log: Yes State: Any (Active for PXM) Privilege: Any

Example
spirit.1.7.PXM.a > cnfcdrscprtn 10000 0 10000
Description

On the current PXM, change the card-level partitioning to give 10000 GLCNs to PAR and
10000 GLCNs to Tag. Note that the value for PNNI currently is 0.

System Response

none

cnfchan

The cnfchan command configures parameters on a specific channel.

Full Name

Configure a Channel

Syntax

cnfchan <port> <chan_num>

where

port

is the port number.

chan_num

is the channel number. On the FRSM, chan_num is the DLCI. On the AUSM, chan_num is the vpi.vci. On the CESM chan_num is the LCN

:

On CESM-8T1E1
Syntax

cnfchan <chan_num> <CDVT> <CLIP> <bufsize> <clockmode> <ISenable> <ForceIS>

where:

chan_num

is the channel number. On the FRSM, chan_num is the DLCI. On the AUSM, chan_num is the vpi.vci. On CESM chan_num is the LCN

CDVT

Cell Delay Variation Tolerance.

125-24000 micro seconds for T1

125-32000 micro seconds for E1

CLIP

Cell Loss Integration Period.

1000-65535 milli seconds

bufsize

Maximum Egress Buffer size, in bytes:

a maximum of 9216 bytes for Structured T1,

a maximum of 16384 bytes for unstructured T1 and all E1.

clock mode

clock mode of the CBR virtual circuit.

1 for synchronous clocking,

2 for Synchronous Residual Time Stamp clocking,

3 for Adaptive clocking

ISenable

1 to disable Idle Suppression feature

2 to enable Idle Suppression feature

ForceIS

1 for normal operation

2 to force Virtual Circuit into Idle signal code suppression

On CESM-T3E3
Syntax

cnfchan <chan_num> <CDVT> <CLIP> <bufsize>

where:

chan_num

is the channel number. On the CESM-T3E3, chan_num is the LCN (valid number is 32)

CDVT

Cell Delay Variation Tolerance.

125-24000 micro seconds for T3

125-32000 micro seconds for E3

CLIP

Cell Loss Integration Period.

1000-65535 milli seconds

bufsize

Maximum Egress Buffer size, in bytes:

a maximum of 16384 for unstructured T3 or E3.

On AUSM-8T1E1
Syntax

cnfchan <chan_num> <RoutingPriority> <MaxCost> <RestrictTrunkType> <PCR> <MCR> <PctUtil>

where:

chan_num

is the channel number. On the AUSM, chan_num is in the range
16-1015.

RoutingPriority

Routing Priority.

1-15 is the range.

MaxCost

Maximum cost.

1-255 is the range.

RestrictTrunk
Type

Restrict Trunk Type.

1: No Restriction

2: Terrestrial Trunk

3: Satellite Trunk

pcr

is the peak cell rate in the range 1-65525 cells/second.

mcr

is the minimum cell rate in the range 1-65525 cells/second.

PctUtil

is the percentage utilization in the range 1-100.

Syntax on PXM

cnfchan LCN chan_rte_pri chan_max_cost chan_restrict_trk_type

where:

LCN

LCN -- a number 16-4111

chan_rte_pri

Route Priority -- a number 1-15

max_cost

Max Cost -- a number 1-255

chan_restrict_trk_type

Restrict Trunk Type -- a number 1-3 (1: No Restriction 2: Terrestrial Trunk 3: Satellite Trunk)

Related Commands

addchan

Cards on Which the Command Executes

FRSM, AUSM, CESM, PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.17.AUSM.a > cnfchan 16 1 5 2 65525 65525 100
Description

On the current AUSM in slot 17, change the configuration for channel 16 to set a routing priority of 1, a maximum cost of 5, restrict trunk routing for this channel to terrestrial trunks only, set the peak cell rate to 655525 cells per second, set the minimum cell rate to 655525 cells per second, and set the percent utilization to 100 percent.

System Response

none

cnfchancacoff

The cnfchancacoff command turns off the connection admission control (CAC) function for a channel.

Full Name

Configure Channel CAC Off

Syntax

cnfchancacoff <chan_num>

where:

chan_num

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

Related Commands

none

Cards on Which This Command Executes

FRSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.27.FRSM.a > cnfchancacoff 16
Description

On the current FRSM in slot 27, change the configuration for channel 16 to turn off the connection admission control (CAC) function.

System Response

none

cnfchanegressq

The cnfchanegressq command configures the egress queue for a specified channel.

Full Name

Configure Channel Egress Queue

Syntax

cnfchanegressq <chan_num> <Qsel> <Qdepth> <QDEThresh> <QECNThresh>

where:

chan_num

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

Qsel

(FRSM-8T1/E1 only) Egress queue select in the range 1-3, where:

1 = High priority queue (Usually used for CBR (Committed Bit Rate) connections).

2 = Low priority queue

3 = Indicates that this entry is not used

Note that selection 3 is for the FRSM-T3/E3/HS2 and FRSM-2CT3 service modules. For these service modules, the queue to which the channel gets mapped is determined by the channel service type.

The default is 2 (low priority queue).

Qdepth

Egress queue depth in the range 1-65535 bytes. It sets the max depth for the queue, before it starts dropping cells. The default value is 65535 bytes.

QDEThresh

Egress queue DE Threshold in the range 1-65535 bytes. It sets the max depth for the queue, before the cells are tagged as discard eligible (DE). The default value is 32767 bytes.

QECNThresh

Egress queue ECN Threshold in the range 1-65535 bytes. It sets the max depth for the queue, before it starts using flow control. The default value is 65535 bytes.

Related Commands

cnfchaningressq

Cards on Which This Command Executes

FRSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.27.FRSM.a > cnfchanegressq 16 1 65535 32767 65535
Description

On the current FRSM in slot 27, change the configuration of the egress queue for channel 16 to set the priority to high, set the maximum queue depth to 65535, the Discard Eligible threshold to 32767, and the ECN threshold to 65535.

System Response

none

cnfchanfst

The cnfchanfst command configures the ForeSight parameters for a frame relay or ATM channel. No messages appear on screen unless an error occurs.

Full Name

Configure Channel ForeSight

Syntax

For FRSM:

cnfchanfst <chan_num> <fst_enable> <mir> <pir> <qir>

where:

chan_num

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

fst_enable

is the ForeSight Enable---1 for enable, 2 for disable.

mir

is the minimum information rate. For FRSM-8T1/E1, the range is 10-8000 in cell/sec. For FRSM-T3/E3/HS2/2CT3, the range is 10-400000 in cell/sec. The default is 1000.

pir

is the peak information rate. For FRSM-8T1/E1, the range is 10-8000 in cell/sec. For FRSM-T3/E3/HS2/2CT3, the range is 10-400000 in cell/sec. The default is 1000.

qir

is the quiescent information rate. For FRSM-8T1/E1, the range is 10-8000 in cell/sec. For FRSM-T3/E3/HS2/2CT3, the range is 10-400000 in cell/sec. The default is 1000.

For AUSM:

cnfchanfst <chan_num> <enable | disable> <fgcra_enable> <ibs> <pcr> <mcr> <icr>

where

chan_num

is the channel number range is 16-1015.

enable | disable

pertains to ForeSight: 1 = disable, 2 = enable.

fgcra_enable

FGCRA enable is for the specified channel: 1 = disable, 2 = enable.

ibs

is the initial burst size in the range 10-5000 cells.

pcr

is the peak cell rate in the range 10-38328 cells/second.

mcr

is the minimum cell rate in the range 10-38328 cells/second.

icr

is the initial cell rate in the range 10-38328 cells/second.

:

Related Commands

dspchan

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.27.FRSM.a > cnfchanfst 16 1 1000 1000 1000
Description

On the current FRSM in slot 27, change the configuration of the ForeSight for channel 16 to enable ForeSight, to set the minimum information rate to 1000 cells per second, to set the peak information rate to 1000 cells per second, and to set the quiescent information rate to 1000 cells per second.

System Response

none

cnfchaningressq

The cnfchaningressq command configures the ingress queue for a specified channel.

Full Name

Configure Channel Ingress Queue

Syntax

cnfchaningressq <chan_num> <Qsel> <Qdepth> <QDEThresh> <QECNThresh>

where:

chan_num

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

Qsel

(FRSM-8T1/E1 only) Ingress queue select in the range 1-3, where:

1 = High priority queue

2 = Low priority queue

3 = Indicates that this entry is not used

Note that selection 3 is for the FRSM-T3/E3/HS2 and FRSM-2CT3 service modules. For these service modules, the queue to which the channel gets mapped is determined by the channel service type.

The default is 2 (low priority queue).

Qdepth

Ingress queue depth in the range 1-65535 bytes. It sets the max depth for the queue, before it starts dropping cells. The default value is 65535 bytes.

QDEThresh

Ingress queue DE Threshold in the range 1-65535 bytes. It sets the max depth for the queue, before the cells are tagged as discard eligible (DE). The default value is 32767 bytes.

QECNThresh

Ingress queue ECN Threshold in the range 1-65535 bytes. It sets the max depth for the queue, before it starts using flow control. The default value is 65535 bytes.

Related Commands

cnfchanegressq

Cards on Which This Command Executes

FRSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.27.FRSM.a > cnfchaningressq 16 1 65535 32767 65535
Description

On the current FRSM in slot 27, change the configuration of the egress queue for channel 16 to set the priority to high, set the maximum queue depth to 65535, the Discard Eligible threshold to 32767, and the ECN threshold to 65535.

System Response

none

cnfchanmap

The cnfchanmap command configures interworking field mapping for a specified channel.

Full Name

Configure Channel Map

Syntax

cnfchanmap <chan_num> <chanType> <FECN/EFCI> <DE to CLP> <CLP to DE>

where:

chan_num

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

chanType

channel type in the range 1-5.

1 = network interworking,
2 = service interworking in transparent mode,
3 = service interworking in translation mode,
4 = FUNI,
5 = frame forwarding

FECN/EFCI

Mapping between FECN and EFCI fields in the range 1-2.

1 = map EFCI, (this option valid only for service interworking)
2 = make EFCI 0

DE to CLP

DE to CLP mapping in the range 1-3.

1 = map DE to CLP, 2 = make CLP 0, 3 = make CLP 1.

CLP to DE

CLP to DE mapping in the range 1-4.

1 = map CLP to DE, 2 = make DE 0, 3 = make DE 1, 4 = ignore CLP (this option valid only for network interworking).

Related Commands

dspchanmap

Cards on Which This Command Executes

FRSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.27.FRSM.a > cnfchanmap 16 1 1 1
Description

On the current FRSM in slot 27, change the configuration of the interworking channel mapping for channel 16 to set the channel type to network interworking, to set EFCI equal to 0, to set the DE to CLP mapping to map DE to CLP, and to set the CLP to DE mapping to map CLP to DE.

System Response

none

cnfchanpol

The cnfchanpol command configures the frame relay policing parameters for a channel. No messages appear on screen unless an error occurs.

Full Name

Configure Channel Policing

Syntax

cnfchanpol <chan_num> <cir> <bc> <be> <ibs> <detag>

where:

chan_num

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

cir

Committed Information Rate in bits per second. The range varies, depending on the service module:

0-1536000 bps for T1

0-2048000 bps for E1

0-44210000 bps for T3

0-34010000 bps for E3

0-51840000 bps for HSSI

Note that for the FRSM-2CT3 service module, the peak value for permissible CIR is 1536000 bits per second.

The default value is 2400 bits per second (bps).

bc

Burst Committed in bytes. The range varies, depending on the service module:

For FRSM-8T1/E1, 0-65535 in bytes

For FRSM-T3/E3/HS2 and FRSM-2CT3, 0-2097151 in bytes

The default value is 5100 bytes.

Note that the Burst Committed value can not be 0 when the Committed Information Rate is not 0.

The Burst Committed value MUST be set to 0 when the Committed Information Rate is set to 0.

be

Burst Excess in bytes. The range varies, depending on the service module:

For FRSM-8T1/E1, 0-65535 in bytes

For FRSM-T3/E3/HS2 and FRSM-2CT3, 0-2097151 in bytes

The default value is 5100 bytes.

Note that the Burst Excess value can not be 0 when the Committed Information Rate is set to 0.

ibs

Initial Burst Size in bytes. The range varies, depending on the service module:

For FRSM-8T1/E1, 0-65535 in bytes

For FRSM-T3/E3/HS2 and FRSM-2CT3, 0-2097151 in bytes

The default value is 100 bytes.

Note that the Initial Burst Size should be less than or equal to the value of Burst Committed when the Committed Information Rate is set to greater than 0. When the Committed Information Rate is set to 0, the Initial Burst Size MUST be set to 0.

detag

Enables Discard Eligible (DE) tagging in the ingress direction only.

1 for enable, 2 for disable.

The default value is 2 (Discard Eligible (DE) tagging disabled).

Related Commands

dspchan

Cards on Which This Command Executes

FRSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.27.FRSM.a > cnfchanpol 16 1 100000 65535 65535 1000 1
Description

On the current FRSM in slot 27, change the configuration of the ForeSight for channel 16 to enable ForeSight, to set the committed information rate to 100000 cells per second, to set the committed burst size to 65535 bytes, to set the burst excess to 65535 bytes, to set the initial burst size to 1000 bytes, and to enable Discard Eligible tagging.

System Response

none

cnfchanq

The cnfchanq command configures a channel's queue parameters on the current AUSM or PXM. No messages appear on screen unless an error occurs.

Full Name

Configure Channel Queue

Syntax

For AUSM

cnfchanq <chan_num> <vc_q_depth> <clp_thresh_high> <clp_thresh_low> <efci_thresh>

where:

chan_num

range 16-1015 on an AUSM

vc_q_depth

Ingress Queue Depth: 0-16000 Cells

clp_thresh_high

CLP Threshold High: 1-16000 Cells

Once the High Cell Loss Priority threshold is exceeded cells can have a CLP bit set, making them discard eligible.

clp_thresh_low

CLP Threshold Low: 1-16000 Cells

The Low Cell Loss Priority threshold

Once the low Cell Loss Priority threshold is passed cells will no longer have the CLP bit set, making them discard eligible.

efci_thresh

EFCI Threshold:

An Explicit Forward Congestion Indicator is sent to the sending node when the threshold is exceeded.

1-16000 Cells

Syntax

For PXM

cnfchanq <chan_num> <discard_option> <clp_thresh_high> <clp_thresh_low> <efci_thresh>

where:

chan_num

range 16-4111 on a PXM

discard_option

Discard option: 1 or 2; where 1 is CLP Hysteresis and 2 is Frame Discard

clp_thresh_high

CLP Threshold High: 1-491520 Cells

Once the High Cell Loss Priority threshold is exceeded cells can have a CLP bit set, making them discard eligible.

clp_thresh_low

CLP Threshold Low: 1-491520 Cells

The Low Cell Loss Priority threshold

Once the low Cell Loss Priority threshold is passed cells will no longer have the CLP bit set, making them discard eligible.

efci_thresh

EFCI Threshold:

An Explicit Forward Congestion Indicator is sent to the sending node when the threshold is exceeded.

1-491520 Cells

Congestion Update

A number 1-4; where 1 is Don't Update, 2 is Set CI Bit, 3 is Set EFCI Bit and 4 is Clear EFCI

Max Cell Count

Max Cell Count: 0-512000 Cells

Related Commands

dspchan

Cards on Which This Command Executes

AUSM, PXM

Attributes

Log: Yes State: Active Privilege: 1-2 on AUSM, Any on PXM

Example
spirit.1.1.AUSM.a > cnfchanq 16 16000 16000 10000 12000
Description

On the current AUSM in slot 1, change the configuration of the channel queue for channel 16 to set the ingress queue depth to 16000, the CLP High threshold to 16000, the CLP Low threshold to 10000, and the EFCI threshold to 12000.

System Response

none

cnfclksrc

The cnfclksrc command configures an interface as a clock source. This command is a PAR command when you execute it on the PXM and a node-level command when you execute it on a service module. Any combination of clock sources are configurable in any order, but you can configure only one clock source each time you execute cnfclksrc.

Full Name

Configure Clock Source

Syntax

Configuring Clock Sources on the Service Modules:

cnfclksrc <slot.port> <clktype>

where:

slot.port

identifies the interface by slot and port. The variable slot is in the range 1-6, 9-14, 17-22, or 25-30, and port is a value in the range 1-n, where n is the highest numbered port on the card.

clktype

is the clock type sourced on the specified interface. Enter p for "primary," s for "secondary," t for "tertiary," or n for "null."

Configuring Network Clock Sources on the PXM:

cnfclksrc <slot.port> <clktype>

where:

slot.port

identifies the interface by slot and port. The variable slot is in the range 7 or 8, and port is a value in the range 1-n, where n is the highest numbered port on the card.

clktype

is the clock type sourced on the specified interface. Enter p for "primary," s for "secondary," t for "tertiary," or n for "null."

Related Commands

dspclksrc

Cards on Which This Command Executes

PXM, FRSM, CESM

Attributes

Log: No State: Active Privilege: 1

Example
tomato01.1.7.PXM.a > cnfclksrc 7.1 p
Description

Configure the primary clock source to port 1 on the current PXM in slot 7.

System Response

none

cnfcmparm

The cnfcmparm command lets you configure parameters that relate to connection rerouting. The specifications govern all connections under PAR control.

Full Name

Configure Connection Management Parameters

Syntax

Note In the following syntax description, the syntax line shows only the argument that indicates a parameter follows but not the actual parameter. The subsequent list defines each argument and the parameter that follows it. This command allows you to specify only one parameter each time you execute cnfcmparm.

cnfcmparm [-cmrb | -cmrrtime | -cmrstime | -cmdup | -cmdnuptime | -cmrrerrs | -cmrrcycint | -cmrrcyc | -cmrrpausetime | -cmmxupdt | -cmrrgrps | -cmrrgrpsz | -cmrrgrpinc | -cmcb | -cmcache | -cmdelay | -cmmxvia]

where:

-cmrb

is the maximum routing bundle size (the maximum number of connections that can be routed in one routing cycle). The range is 1 through 29. The default value is 24.

-cmrrtime

is the reroute timer. The range is 0 through 900. The units of measure are milliseconds. The default value is 0.

-cmrstime

specifies whether the reroute timer should reset when the routed connection's path fails. This timer can be enabled (yes) or disabled (no) with this parameter. If set to yes, the timer resets after detecting path fail. The default value is Yes.

-cmdup

is the maximum number of connections the switch can down or up during a single rerouting pass. The range is 0 through 255. The default value is 50.

-cmdnuptime

is the minimum time between scheduled down states. The range is 1000 through 65535. The units of measure are milliseconds. The default value is 30000 (30 seconds).

-cmrrerrs

is the threshold limit for reroute failures. The range is 0 through 65535. The default value is 50. Setting this parameter to 0 disables the feature.

-cmrrcycint

is the interval for the connection management reroute cycle in minutes. It specifies the time (in minutes) to wait before re-attempting to route a connection that had exceeded the reroute failure threshold. The range is 1 through 8. The default value is 5.

-cmrrcyc

is the number of failed reroutes for a group before software declares the connection to be unrouteable. The range is 0 through 255. The default value is 10.

-cmrrpausetime

is the time interval between two routing cycles. The range is 0 through 65535. The units of measure are milliseconds. The default value is 0.

-cmmxupdt

is the maximum number of connection management updates in one scheduled update cycle. The range is 1 through 233. The default value is 10.

-cmrrgrps

is the total number of reroute groups. The range is 1 through 200. The default value is 50.

-cmrrgrpsz

is the minimum size of the reroute group. The units of measure are cell load units. The range is 0 through 9600. The default value is 0.

-cmrrgrpinc

is the increment in group size from one reroute group to the next reroute group. The range is 1 through 9600. The default value is 100.

-cmcb

is the cost based routing feature. This feature can be enabled (yes) or disabled (no) with this parameter. The default value is disabled (no).

-cmcache

allows you to store cost based routing routes in cache. This feature can be enabled (yes) or disabled (no) with this parameter. The default value is disabled (no).

-cmdly

allows you to enable or disable compensation for delay while using cost based routing. This feature can be enabled (yes) or disabled (no) with this parameter. The default value is disabled (no).

-cmmxvia

is the maximum number of via connections that can be routed through this node before software declares the connection to be unrouteable. The range is 0 through 80000. The default value is 50000.

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: SuperUser

Example
wilco.1.7.PXM.a > cnfcmparm -cmrb 250 -cmrrtime 21 -cmrstime y -cmdnup 50 -cmdnuptime 30000 -cmrrerrs 5 -cmrrcycint 5 -cmrrcyc 1 -cmrrpausetime 0 -cmmxupdt 10 -cmrrgrps 50 -cmrrgrpsz 0 -cmcb n -cmcache n -cmdly n -cmmxvia 1024
Description

Configure connection rerouting parameters

System Response

none

Enter the dspcmparm command to confirm.

wilco.1.7.PXM.a > dspcmparm


CONNECTION MANAGEMENT PARAMETERS
    1   Maximum Routing Bundle            250
    2   Reroute Timer                     21
    3   Reset Timer                       YES
    4   Max Down/Up Per Pass              50
    5   Down/Up Timer                     30000
    6   Max Route Errs per cycle          5
    7   Time between Rrt cycles           5
    8   Max. Rrt Err cycles               1
    9   Routing pause timer               0
    10  Max msgs sent per update          10
    11  # of reroute groups used          50
    12  Starting size of RR grps          0
    13  Increment between RR grps         0
    14  Cost Based routing                NO
    15  Use cache based route selection   NO
    16  Use end-to-end delay for routing  NO
    17  Max Via Connections               1024

cnfcon

Configures connection parameters on the PXM, AUSM, FRSM, or CESM. The applicable parameters were previously specified by the addcon command.

Full Name

Configure Connection

Syntax

On FRSM or AUSM:

cnfcon <port number>. <DLCI> <connection type> <CIR> <adm control>

On CESM:

cnfcon <chan_num> <vpcflag> <connection service type> <routing_priority> <max_cost> <restricted_trunk_type> <pcr> <mcr> <pct_util>

On PXM:

cnfcon <conn_ID> <routing_priority> <max_cost> <restricted_trunk_type> [<CAC>]

Related Commands

addcon, dspcon, dspcons, delcon

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: Yes State: Active Privilege: Any

Example
spirit01.1.7.PXM.a > cnfcon 1.2.5 15 255 3 2

Description

Configures the connection on port 1 with a VCI of 2 and a VPI of 5 to use routing priority 15, a maximum routing cost of 255, to not use satellite trunks, and to enable connection admission control.

System Response

none

cnfdate

The cnfdate command lets you configure the date.

Full Name

Configure Date

Syntax

cnfdate <mm/dd/yyyy>

where:

mm

identifies the month. This is a two digit number in the range 01 through 12.

dd

identifies the day. This is a two digit number in the range 01 through 31.

yyyy

identifies the year. This is a four digit number in the range 0000 through 9999.

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example
excel.1.3.PXM.a > cnfdate 11/24/1999
Description

Configure the date to be 11/24/1999

System Response
excel.1.3.PXM.a > cnfdate 11/24/1999
 
 
  Date = 11/24/1999
 

cnfextclk

The cnfextclk command lets you configure the line type and impedance of the external clocking source.

Full Name

Configure External Clocking

Syntax

cnfextclk <ClockType> <Impedance>

where:

ClockType

is the type of line the clocking will be extracted from. Enter 1 for T1, or 2 for E1.

Impedance

is the impedence of the line selected as the external clocking source. Enter 1 for 75 ohms, 2 for 100 ohms, or 3 for 120 ohms.

Related Commands

dspextclk

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 3

Example
excel.1.3.PXM.a > cnfextclk 2 2
 
Description

Configure the clocking to be extracted from an E1 line with an impedance of 100 ohms.

System Response

none

cnffst

The cnffst command configures the ForeSight parameters for the current card.

Full Name

Configure ForeSight

Syntax

cnffst <rate_up> <rate_down> <rate-fast_down> <qir_time_out> <rtd_interval>

where:

rate_up

rate up in the range 1-100. If free bandwidth is available, the rate at which ForeSight increases transmission (as a percentage of MIR).

rate_down

rate down in the range 1-100. If free bandwidth becomes unavailable, the rate at which ForeSight decreases transmission (as a percentage of current rate).

rate-fast_down

rate fast down in the range 1-100. If a cell is dropped or the TxQ is full, the rate at which ForeSight decreases transmission (as a percentage of current rate).

qir_time_out

QIR timeout period before resetting IR to QIR in the range 1-255 seconds

rtd_interval

Interval between Round Trip Delay measurement requests in the range 1-255 seconds

Related Commands

dspfst

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

cnfif

The cnfif command modifies parameters for an existing broadband interface on a PXM. System software does not allow you to conflict with existing configurations. You may need to reduce the bandwidth allocation or VPI/VCI range on one or more interfaces before you expand the resources for a interface. Refer to the upif command description for more information on resource partitioning.

Full Name

Configure a Broadband Interface

Syntax

cnfif <if_num> <pct_bw> <min_vpi> <max_vpi>

where:

if_num

is the number of the logical interface. The range for if_num is 1-32

pct_bw

is the percent of the line bandwidth for the logical interface. The pct_bw range
is 0-100. The value applies to both the ingress and egress.

min_vpi

is the minimum VPI value. The range is 0-255 for UNI or 0-4095 for NNI.
Typically, the UNI applies to a line connecting a stand-alone node to a workstation.

max_vpi

is the maximum VPI value. The range is 0-255 for UNI or 0-4095 for NNI.
Typically, the UNI applies to a line connecting a stand-alone node to a workstation.

Related Commands

upif

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
wilco.1.7.PXM.a > cnfif 1 10 0 19
Description

Configure broadband interface number 1 to use 10% of the line bandwidth for both ingress and egress, have a minimum virtual path interface (VPI) of 0, and a maximum virtual path interface (VPI) of 19.

System Response

none

Enter the dspif command to confirm.

wilco.1.7.PXM.a > dspif


 
 ifNum  Status  Line  ingrPctBw egrPctBw minVpi maxVpi
------------------------------------------------------
  1     Ena       1       10       10        0     19
 

cnfifastrk

The cnfifastrk command lets you specify that a logical interface on the PXM acts as a feeder trunk. The application for this command is dependent upon the activation of the paid feature option of feeder capability on the MGX 8850 node. Before configuring the interface as a feeder trunk the option must be activated with the cnfswfunc command. Therefore, the default is "rtrk" for routing trunk. The routing trunk utilization applies to both a routing node and a stand-alone node.

Full Name

Configure Interface as Trunk

Syntax

cnfifastrk <slot.port> <iftype>

where:

slot.port

is the slot and port number of the line you want to serve as the trunk, in the format slot.port, where slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.

iftype

is the type of trunk---"ftrk" for a feeder trunk or "rtrk" for a routing trunk. The default is "rtrk."

Related Commands

uncnfifastrk

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 2

Example
wilco.1.7.PXM.a > cnfifastrk 7.1 ftrk
Description

Configure line 1 on the PXM in slot 7 as a feeder trunk.

System Response

none

cnfifip

The cnfifip command configures the interface address. The configurable addresses are for LAN, SLIP, and ATM.

Full Name

Configure Interface Address

Syntax

cnfifip <Interface> <IP_Addr> <Net_Mask> <BrocastAddr>

where:

Interface

Interface is the number 26, 28, or 37, as follows:

· 26 for Ethernet

· 28 for SLIP

· 37 for ATM

IP_Addr

IP address = nnn.nnn.nnn.nnn, where the range for n is 1-9, and nnn is < 256.

Net_Mask

NetMask = nnn.nnn.nnn.nnn, where the range for n is 1-9, and nnn is < 256.

BrocastAddr

BroadcastAddress = nnn.nnn.nnn.nnn, where the range for n is 1-9, and nnn is < 256.

Related Commands

dspifip

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Any Privilege: SuperUser

Example

wilco.1.7.PXM.a > cnfifip 28 192.169.3.18 255.255.255.000

Description

Configure the SLIP interface to use the IP address 192.169.3.18 and the netmask 255.255.255.000.

System Response

none

Enter the dspifip command to confirm.

wilco.1.7.PXM.a > dspifip

   Interface     IPAddress             NetMask       BroadcastAddress
  ------------  -----------------  ----------------- -----------------
   Ethernet     172.29.37.40        255.255.255.000
   Slip         192.169.3.18        255.255.255.000
   ATM                              255.255.255.000
 
wilco.1.7.PXM.a >

cnfilmi

The cnfilmi command configures a port's local management interface. No messages appear on screen unless an error occurs.

Full Name

Configure ILMI

Syntax

cnfilmi <port_num> <signal_type> <vpi> <vci> <scr> <trap_enable> <min_trap_int> <keep_alive>

where:

port_num

port number in the range 1-8

signal_type

signalling type: 1 = other, 2 = no signalling, and 3 = ILMI

vpi

virtual path identifier in the range 0-259

vci

virtual circuit identifier in the range 0-65535

trap_enable

ILMI trap enable: 1 = disable, 2 = enable

min_trap_int

minimum trap interval in the range 1-10 seconds.

keep_alive

enable for Keep Alive Polling: 1 = disable, 2 = enable

Related Commands

dspilmi, dspilmicnt

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1, (Cisco for PXM)

cnfimagrp

The cnfimagrp command configures delay and resilient links IMA (inverse multiplexing ATM) parameters on the current AUSM card.

Full Name

Configure IMA Group

Syntax

cnfimagrp <grp> <max_diff_delay> <n_res_lns>

where:

grp

IMA group number. The range is 1 through 8.

max_diff_delay

Maximum tolerable differential delay between the various links in the IMA group in milliseconds. The range depends on the type of service module:

0-275 for AUSM8-T1

0-200 for AUSM8-E1.

n_res_lns

number of resilient links in the inverse multiplexer. This defines the number of links the system can lose from this IMA group without bringing it down.

The default is one less than the number of links in the selected group.

Related Commands

dspimagrp, dspimagrps, dspimagrpcnt

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
flyers01.1.17.AUSM.a > cnfimagrp 1 -rwdiff 5 -severity 2 -maxdiff 3 -red 2
Description

Configure AIMUX group 1 on the AUSM card in slot 17 to have a read/write pointer differential of 5, a link loss severity of 2, a maximum tolerable differential delay of 5, and 2 redundant links.

System Response

none

cnfln

The cnfln command lets you configure line characteristics for the current card. The line types are SONET, T3, E3, T1, or E1.

Full Name

Configure Line

Syntax

For a T1 or E1 line on a service module:

cnfln <line_num> <line_code> <line_len> <clk_src> [E1-signaling]

where:

line_num

the line number in the range 1-8

line_code

line coding:

2 for B8ZS, applies to T1

3 for HDB3, applies to E1

4 for AMI, applies to T1 or E1

line_len

is a number that points to a length:

For T1: 10-15

For E1 with SMB module: 8

For E1 with RJ48 module: 9

clk_src

is the clock source:

1 for loop clock

2 for local clock

E1-signaling

CAS: CAS, no CRC
CAS_CRC: CAS with CRC
CCS: CCS no CRC
CCS_CRC: CCS with CRC
CLEAR: Clear E1

For T3 lines on a PXM:

cnfln -ds3 <LineNum> -lc <LineCoding> -len <LineLength> -oof <LineOOFCriteria>
-cb <LineAIScBitsCheck> -lpb <LoopCmd> -rfeac <LineRcvFEACValidation>

where:

-ds3

indicates that the line is a T3.

LineNum

is the line number in the format slot.line. If the slot number is 7, 15, or 31, the range for line is 1-n, where n is the highest line number.

-lc

indicates that the line coding specification (LineCoding) follows.

LineCoding

is the line coding for Zero Code Suppression. Enter a "1" for B3ZS on a dsx3 line or a "2" for HDB3 on an E3 line.

-len

indicates that the line length specification (LineLength) follows.

LineLength

is the length of the line. Type a "1" for less than 225 feet or a "2" for 225 feet or more.

-oof

indicates that the out of frame criteria specification follows.

LineOOFCriteria

sets the threshold for triggering an Out Of Frame condition. Type a "1" for 3 out of 8 (an Out Of Frame condition is declared if at least 3 of 8 framing bits are in error) or
a "2" for 3 out of 16 (an Out Of Frame condition is declared if at least 3 of 16 framing bits are in error).

-cb

indicates the c-bit test enable (LineAIScBitsCheck) follows.

LineAIScBitsCheck

determines the test of the c-bit in response to AIS status. The choices for LineAIScBitsCheck are 1-2, where "1" means "check the c-bit," and a "2" means "ignore the c-bit."

-lpb

indicates that the loopback specification follows.

LoopCmd

determines the loopback configuration of the DS3/E3 interface.

The values mean:

dsx3NoLoop

Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as its value.

dsx3RemoteLineLoop

Near End loops back Remote data

dsx3LocalLineLoop

Near End loops back Local data(outbound).

dsx3InboundLoopback

Near End in bound loopback Local data(inbound).

-rfeac

indicates the LineRcvFEACValidation specification follows.

LineRcvFEACValidation

is the specification for the FEAC (far-end alarm and control) code validation criteria. The possible entries are 1-2, where a "1" specifies "4 out of 5," and a "2" specifies "8 out of 10."

If 1 is specified then a valid FEAC code is declared if 4 of 5 codes match. When 2 is specified then a valid FEAC code is declared when 8 of 10 codes match.

For an E3 line on a PXM:

cnfln -e3 <LineNum> -lc <LineCoding> -len <LineLength> -lpb <LoopCmd>
-topt <TrailTraceOption> -txtt <txTrailTrace> -txma <txTimingMarker>
-rxma <rxTimingMarker> -txpt <txPayloadType>

where:

-e3

indicates that the line is an E3.

LineNum

is the line number in the format slot.line. If the slot number is 7, 15, or 31, the range for line is 1-n, where n is the highest line number.

-lc

indicates that the line coding specification (LineCoding) follows.

LineCoding

is the line coding. Enter a "1" for B3ZS on a dsx3 line or a "2" for HDB3 on an E3 line.

-len

indicates that the line length specification (LineLength) follows.

LineLength

is the length of the line. Type a "1" for less than 225 feet or a "2" for 225 feet or more.

-lpb

indicates that the loopback specification follows.

LoopCmd

determines the loopback configuration of the E3 interface.

The values mean:

dsx3NoLoop

Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as its value.

dsx3RemoteLineLoop

Near End loops back Remote data

dsx3LocalLineLoop

Near End loops back Local data (outbound).

dsx3InboundLoopback

Near End in bound loopback Local data (inbound).

-topt

indicates the trail trace enable follows.

TrailTraceOption

is the enable for trail trace. The values for TrailTraceOption are 1-2, where a "1" means disable, and a "2" means enable.

-txtt

means the transmit trail trace specification follows.

txTrailTrace

is the length of the trail trace string in the transmit direction (away from the switch). The maximum length of txTrailTrace is 16 bytes.

-txma

indicates the traceability specification for timing markers for the transmit direction follows.

txTimingMarker

specifies whether the timing marker is traceable. Type a "1" to make it traceable or a "2" to make it untraceable.

-rxma

indicates the traceability specification for timing markers for the receive direction follows.

rxTimingMarker

specifies whether the timing marker is traceable. Type a "1" to make it traceable or a "2" to make it untraceable.

-txpt

indicates the payload type specification follows.

txPayloadType

specifies the payload type. The range is 1-4. Enter a "1" for unequipped, a "2" for equipped, a "3" for ATM, or a "4" for sdhtu12s.

For a SONET line on a PXM:

cnfln -sonet <LineNum> -slt <LineType> -lpb <LoopCmd> -smask <HCSmasking>
-sps <PayloadScramble> -sfs <FrameScramble>

where:

-sonet

indicates that the line is an SONET line.

LineNum

is the line number in the format slot.line. The slot number must be 7, and the range for line is 1-n, where n is the highest line number.

-slt

indicates that the line type follows.

LineType

is the line type. The values for LineType have the range 1-4. Type a number to specify one of the following line types:

"1" for sonetSts3c

"2" for sonetStm1

"3" for sonetSts12c

"4" for sonetStm4

-lpb

indicates that the loopback enable follows.

LoopCmd

is the enable for loopback. Enter a "1" to disable or a "2" to enable loopback

-smask

indicates that the HCS masking enable follows.

HCSmasking

is the enable for HCS masking. Enter a "1" to disable or a "2" to enable HCS masking.

-sps

indicates that the payload scramble enable follows.

PayloadScramble

is the enable for payload scramble. Enter a "1" to disable or a "2" to enable payload scramble.

-sfs

indicates that the frame scramble enable follows.

FrameScramble

is the enable for frame scramble. Enter a "1" to disable or a "2" to enable frame scramble.

Related Commands

addln, delln, dsplns, dspln

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: Yes State: Active Privilege: 1

Example
wilco.1.4.AUSM.a > cnfln 4 2 10 1 
Description

Configure line 4 on the current card (an AUSM in slot 4) to be T1 with B8ZS line coding, have a length of 10, and use the loop clock as a clock source.

System Response

No system response unless an error occurs.

cnfname

The cnfname command configures a name for the switch. The name can be up to eight characters. The name can consist of letters, special characters "_" and "-" and numbers. It must begin with a letter and cannot contain spaces. The name is case sensitive.

Full Name

Configure Name

Syntax

cnfname <node name>

where node name can have up to eight characters.

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 1

Example
NODENAME.1.7.PXM.a > cnfname kanchendzonga
Description

The prompt returns with the new name. However, on the command line, the name is truncated to eight characters because of the information displayed in the prompt.

System Response
 
kanchend.1.3.PXM.a > 

cnfnwip

The cnfnwip command configures the network IP address for the switch.

Full Name

Configure Network IP Address

Syntax

cnfnwip <IP_Addr> <Net_Mask> <BrocastAddr>

where:

IP_Addr

IP address = nnn.nnn.nnn.nnn, where the range for n is 1-9, and nnn is < 256.

Net_Mask

NetMask = nnn.nnn.nnn.nnn, where the range for n is 1-9, and nnn is < 256.

BrocastAddr

BroadcastAddress = nnn.nnn.nnn.nnn, where the range for n is 1-9, and nnn is < 256.

Related Commands

dspnwip

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: SuperUser

Example
wilco.1.7.PXM.a > cnfnwip 192.5.5.5
 
Description

Configure the network IP address for the switch as 192.5.5.5.

System Response
 
pmmNodeNameTrapCBFunc : Status is 0, index is 9, pNodeName is wilco
 
 
Node IP : 192.5.5.5
 

cnfpasswd

The cnfpasswd command changes a password for the specified User ID. When the command is entered without arguments, you are changing your own password. Prompts appear for you to enter the new password and confirm it.

Full Name

Configure Password

Syntax

cnfpasswd [user_id] <new password> <new password again>

Related Commands

cnfpwd

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
spirit4.1.8.PXM.a > cnfpasswd

Description

Change your own password. Prompts appear for you to enter the new password and confirm it.

System Response
Enter password:
Re-enter password:
 
 
spirit4.1.8.PXM.a >
 

cnfplpp

The cnfplpp command configures PLPP parameters on the current AUSM card.

Full Name

Configure PLPP

Syntax

cnfplpp <phy_port_num> <loopback> <scramble> <singlebit_errcorr_ena>

where:

phy_port_num

Physical port number in the range 1-8

loopback

PLPP loopback specification with possible values of 1-3, where:

  • 1 = no loopback

  • 2 = remote loopback

  • 3 = local loopback

scramble

cell scramble enable, where: 1 = no scramble, 2 = scramble.

singlebit_errcorr_ena

single-bit error correction enable, where, 1 = disable, 2 = enable.

Related Commands

dspplpp

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit3.1.22.AUSM8.a > cnfplpp 1 1 1 1
 
 
Description

Configure the PLPP parameters on port 1 on the current AUSM card in slot 22 to disable cell scramble, to disable PLPP loopback, and to disable Single-bit error correction.

System Response

none

Verify your work with the dspplpp command.

spirit3.1.22.AUSM8.a > dspplpp 1

  PhysicalPortNumber:            1
  CellFraming:                   ATM
  CellScramble:                  No Scramble
  Plpp Loopback:                 No Loopback
  Single-bit error correction:   Disabled
 
 
Syntax : dspplpp "port_num"
         physical port number -- value should be between 1 to 8
 
 
spirit3.1.22.AUSM8.a >

cnfport

The cnfport command configures a service port on an FRSM or a PXM.

The screen does not display a message after successful command entry. The configuration can be verified using the dspport command.

The syntax for this command differs according to the service module being addressed.

Full Name

Configure Port

Summary for FRSM

Syntax

cnfport <port_num> <lmi_sig> <asyn> <T391> <T392> <N391> <N392> <N393>

where:

port_num

logical port number is in the range of values 1-192 for an 8 port FRSM card (T1), 1-248 for an 8 port FRSM card (E1), or 1-4 for a 4 port FRSM HS1 or HS2 card or unchannelized E1 or T1 FRSM, or 1-2 for a 2 port FRSM HS1 or HS2 card or unchannelized E3 or T3 FRSM. 1-56 for a channelized T3 FRSM.

lmi_sig

LMI signaling: protocol type. 1 = Other, 2 = None, 3 = StrataLMI,
4 = AnnexAUNI, 5 = AnnexDUNI, 6 = AnnexANNI,
7 = AnnexDNNI

asyn

asynchronous update is (y)es or (n)o. The default value is disabled (no).

T391

T391 timer is in the range 5-30 seconds. It sets the interval in seconds for NNI status polling. The default is 10.

T392

T392 timer is in the range 5-30 seconds. It sets the interval in seconds for UNI status polling. The default is 15.

N391

N391 counter is in the range 1-255. This sets the number of UNI/NNI polling cycles. The default is 6.

N392

N392 counter is in the range 1-10. This sets the UNI/NNI error threshold. The default is 3.

N393

N393 counter is in the range 1-10. This sets the UNI/NNI monitored events threshold. Must be greater than N392. The default is 4.

Possible errors are:

Related Commands

addport, delport, dspport, dspports

Cards on Which This Command Executes

PXM, FRSM

Attributes

Log: Yes State: Active Privilege: Any

Example
spirit3.1.8.PXM.a > cnfport 1 100 0 4095
 
 
Description

Configure the port parameters on port 1 on the current PXM card in slot 8 to allocate all the bandwidth and to set the VPI range to 0 through 4095.

System Response

none

cnfportcllm

The cnfportcllm command configures the CLLM (Consolidated Link Layer Management) parameters for a specified port on the current card. Use CLLM to pass ForeSight to another Cisco WAN Switching network using NNI.

Full Name

Configure Port CLLM

Syntax

cnfportcllm <port_num> <CLLMEN> <CLLMTM>

where:

port_num

logical port number is in the range of values 1-192 for an 8 port FRSM card (T1), 1-248 for an 8 port FRSM card (E1), or 1-4 for a 4 port FRSM HS1 or HS2 card or unchannelized E1 or T1 FRSM, or 1-2 for a 2 port FRSM HS1 or HS2 card or unchannelized E3 or T3 FRSM. 1-56 for a channelized T3 FRSM.

CLLMEN

CLLM Enable is either 1 = Disable or 2 = Enable. The default value is disabled (1).

CLLMTM

CLLM Timer is in the range 40-5000 milliseconds. This is the amount of time to wait to receive CLLM updates before timing out. The default value is 1000 (1 second).

Related Commands

dspportcllm

Cards on Which This Command Executes

FRSM

Attributes

Log: Yes State: Active Privilege: 1-2

cnfportq

The cnfportq command configures a port's queue parameters on the current AUSM. No messages appear on screen unless an error occurs.

Full Name

Configure Port Queue

Syntax

cnfportq <port_num> <q_num> <q_algo> <service_seq> <q_depth> <clp_high> <clp_low> <efci_thres>

where:

port_num

port_num is a port number in the range 1-8

q_num

q_num is the queue number in the range 1-4: 1 is CBR 2 is ABR 3 is VBR and 4 is UBR

q_algo

queue algorithm is the queue algorithm in the range 1-5, 0 = disable queue

service_seq

service sequence is the service sequence number in the range 1-16

q_depth

queue depth is the maximum queue depth in the range 1-16000 cells

clp_high

CLP high is the high Cell Loss Priority in the range 1-16000 cells

clp_low

CLP low is the low Cell Loss Priority in the range 1-16000 cells

efci_thres

EFCI threshold is the EFCI threshold in the range 1-16000 cells

Related Commands

none

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1

cnfportrscprtn

The cnfportrscprtn command configures the resources each controller application receives at a port. The reasons for configuring partitions at the port level:

If you used the addcdrscprtn or cnfcdrscprtn command and configured card-level resource partitioning to be off, you must configure resources at each port.

Optionally, if you have used addcdrscprtn or cnfcdrscprtn and configured resource partitioning to be merely on or on with specific controller allocations, you can modify the partitioning at the port level by using cnfportrscprtn.

Full Name

Configure Port Resource Partition

Syntax for Service Modules:

cnfportrscprtn <portnum> <controller> <conn ID range> <percent bandwidth> [number of conns]

where:

port_num

is the logical port number is in the range of values 1-192 for an 8 port FRSM card (T1), 1-248 for an 8 port FRSM card (E1), or 1-4 for a 4 port FRSM HS1 or HS2 card or unchannelized E1 or T1 FRSM, or 1-2 for a 2 port FRSM HS1 or HS2 card or unchannelized E3 or T3 FRSM. 1-56 for a channelized T3 FRSM.

controller

specifies the controller type: 1=PAR, 2=PNNI (currently not used), 3=Tag

conn ID range

is the range of connection IDs available to the controller.

percent bandwidth

is the percentage of the port bandwidth available to the controller. This specification applies to ingress and egress.

number of conns

is the optional specification of the actual number of connections available to a controller on a port.

Syntax for PXM:

cnfportrscprtn <if_num> <ctrlr_num> <ingr_pct_bw> <egr_pct_bw> <min_vpi> <max_vpi> <min_vci> <max_vci> <max_chans>

where:

if_num

is the logical interface number in the range 1- 32.

ctrlr_num

is the number for a network control application, as follows: enter a 1 for PAR, a 2 for PNNI, or a 3 for TAG.

ingr_pct_bw

is the percent of ingress bandwidth---a number in the range 0-100.

egr_pct_bw

is the percent of egress bandwidth---a number in the range 0-100.

min_vpi

is the minimum VPI Value---a number in the range 0-4095.

max_vpi

is the maximum VPI Value---a number in the range 0-4095.

min_vci

is the minimum VCI Value---a number in the range 0-65535.

max_vci

is the maximum VCI Value---a number in the range 0-65535.

max_chans

is the maximum number of GLCNs---a number in the range 0-32767.

Related Commands

none

Cards on Which This Command Executes

PXM, AUSM, FRSM, CESM, VISM

Attributes

Log: Yes State: Active Privilege: 1 (Service for PXM)

cnfpref

cnfpref ANYUSER ACTIVE_ONLY -

spirit4.1.8.PXM.a > cnfpref 1 1 54 887 
ERR: incorrect number of parameters: (not enough)
        slot number -- a number between 1 and 6 or 9 and 14
        port number -- a number between 1 and 255
        vpi -- a number between 0 and 4095
        vci -- a number between 0 and 65535
        preferred route -- a route string of ltrk/nodename starting from master
 
spirit4.1.8.PXM.a >
 
 

cnfpwd

The cnfpwd command changes a password. Prompts appear for the old and new passwords when the command is entered (without arguments).

Full Name

Configure Password

Syntax

cnfpwd <old password> <new password> <new password again>

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example

cnfpwd

System Response
old password: 
 
new password: 
 
verify new password: 
 
 

cnfrscprtn

The cnfrscprtn command lets you modify an existing resource partition. Refer to the description of addrscprtn for information on resource partitions.

A resource partition on a PXM consists of a percent of bandwidth, a VPI/VCI range, and the number of global logical connection numbers (GLCNs) available to a network control application. The current network control applications are Portable AutoRoute (PAR) and Tag Switching.

Full Name

Configure Resource Partition

Syntax

cnfrscprtn <if_num> <ctrlr_num> <ingr_pct_bw> <egr_pct_bw> <min_vpi> <max_vpi> <min_vci> <max_vci> <max_chans>

where:

if_num

is the logical interface number in the range 1- 32.

ctrlr_num

is the number for a network control application, as follows: enter a 1 for PAR, a 2 for PNNI, or a 3 for TAG.

ingr_pct_bw

is the percent of ingress bandwidth---a number in the range 0-100.

egr_pct_bw

is the percent of egress bandwidth---a number in the range 0-100.

min_vpi

is the minimum VPI Value---a number in the range 0-4095.

max_vpi

is the maximum VPI Value---a number in the range 0-4095.

min_vci

is the minimum VCI Value---a number in the range 0-65535.

max_vci

is the maximum VCI Value---a number in the range 0-65535.

max_chans

is the maximum GLCNS---a number in the range 0-32767.

Related Commands

addrscprtn, delrscprtn, dspifrsc, dspifs, dsprscprtns, dsprscprtn, dsplnrsc

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Service

Example
MGX-01.1.2.PXM.a > cnfrscprtn 1 1 100 100 0 4095 0 65535 32767 
 

cnfslftst

The cnfslftst command configures the self test routine on the current card.

Full Name

Configure Self Test

Syntax

cnfslftst -en <SelftestEnable> -tm <SelftestPeriod>

where:

-SelftestEnable

Enable/disable self test, 1 = disabled, 2 = enabled.

SelftestPeriod

Period, in minutes, between self tests in the range 1-60.

Related Commands

clrslftst, dspslftst, runslftstno

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: Any

Example
spirit3.1.22.AUSM8.a > cnfslftst -en 2 -tm 5
 
Description

Enable the self test for the AUSM in slot 22, with a self test period of five minutes.

System Response

none

cnfsrmclksrc

The cnfsrmclksrc command configures the SRM clock source to be acquired from either the PXM or from an SRM-3T3 T3 line.

Full Name

Configure SRM Clock Source

Syntax

cnfsrmclksrc -ds3 <T3 line number> -srmclk <source number>

where:

T3 line number

SRM-3T3 T3 line number in the format slot.port where slot is either 7, 15 or 31, and line is in the range 1 to n, where n is the highest available port number on the card..

source number

1: backplane clock for PXM or 2: recovery clock from T3 line. 1 is the default.

Related Commands

dspsrmclksrc

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

cnfstatsmgr

The cnfstatsmgr command identifies the IP address of the workstation with the statistics manager to the MGX 8850 node. If the MGX 8850 node does not have this IP address, it refuses requests for statistical information from the workstation that is running Cisco WAN Manager.

Full Name

Configure Statistics Manager

Syntax

cnfstatsmgr <IP_Addr>

where:

IP_Addr

IP address = nnn.nnn.nnn.nnn, where n = 0-9, and nnn < 256.

Related Commands

dsptrapmgr

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

cnfswfunc

The cnfswfunc command configures certain node-level, paid features on an MGX 8850 switch. The features are the feeder implementation of the switch and virtual source/virtual destination (VSVD) control for ABR traffic. The defaults are disabled for VSVD and the routing implementation of the MGX 8850 switch.

Full Name

Configure Software Function

Syntax

cnfswfunc [<-vsvd enable(yes) | disable(no)>] | [<-ndtype> <fdr | routing>]

where:

-vsvd

indicates the VSVD enable/disable follows.

e or d

enables or disables VSVD for ABR connections on the node.

-ndtype

indicates the node implementation follows. The choices are "fdr" for a feeder implementation or "routing" for either the stand-alone or routing node implementation. The default is routing.


Note The cnfswfunc command does not let you enable more than one feature at a time.
Related Commands

dspswfunc

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Service

Example

wilco.1.7.PXM.a > cnfswfunc -vsvd yes -ndtype routing

System Response

none

cnfsysparm

The cnfsysparm command lets you configure certain system-level parameters.

Full Name

Configure System Parameters

Syntax

cnfsysparm [-tspktage <TS Packet Age> -connfail <enable(yes)/disable(no)> ]

where:

-tspktage

a packet age for time-stamped packets follows.

TS Packet Age

is the number of milliseconds a time-stamped packet can exist before the system discards it.

-connfail

indicates the enable for connection failure response follows.

yes or no

enables or disables connection failure response.

Related Commands

dspsysparm

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 1

Example
wilco.1.7.PXM.a > cnfsysparm -tspktage 10000 -connfail yes
System Response

none

cnftime

The cnftime command configures the time. The node uses a 24-hour clock.

Full Name

Configure Time

Syntax

cnftime <hh:mm:ss>

where:

hh

is the hour of the day and has the range 1-24.

mm

is the minute of the hour and has the range 1-60.

ss

is the number of seconds in the minute and has the range 1-60.

Related Commands

cnftmzn, cnfdate

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example

cnftime 14:22:03

System Response
excel.1.3.PXM.a > cnftime 14:11:22
11/14/98-14:11:22 3  tDbgCmdTask 1220 informational        : TIME/DATE updated        
 
11/14/98-14:11:22 3  StrataCom    0 cnftime 14:11:22    
 
 

cnftmzn

The cnftmzn command configures the timezone for the switch.

Full Name

Configure Timezone

Syntax

cnftmzn <timezone>

where:

timezone

is 1 for GMT, 2 for EST, 3 for CST, 4 for MST, 5 for PST

Related Commands

cnftime, cnfdate

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example

cnftmzn 3

Description

Configures the timezone in the node to U.S. Central Standard Time.

System Response

none

cnftmzngmt

The cnftmzngmt command configures the timezone for the shelf relative to GMT.

Full Name

Configure Timezone Relative to GMT

Syntax

cnftmzngmt <timeoffsetGMT>

where:

timeoffsetGMT

is the offset in hours from GMT. The range of possible values for timeoffsetGMT is -12 through 12.

Related Commands

cnftmzn, cnftime, cnfdate

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: Superuser

Example

cnftmzngmt 4

Description

Sets time zone in the shelf to GMT plus 4 hours.

System Response

none

cnftrapip

The cnftrapip command is used to configure the IP address, that is put in all out-going traps from the shelf. This should be configured to one of the interface addresses. The system displays errors if they occur.

Full Name

Configure Trap IP Address

Syntax

cnftrapip <ip_addr>

where:

ip_addr

is the IP address of the trap manager in the format nnn.nnn.nnn.nnn, where n = 0-9, and nnn < 256. The default value is 255.255.255.255.

Related Commands

None

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
 
spirit4.1.8.PXM.a > cnftrapip 192.169.3.102 
 
System Response

none

cnftrapmgr

The cnftrapmgr command enables, configures, or disables the trap manager function. If you enable the trap manager, this command lets you configure the number and IP address of the trap manager you intend to receive traps. The system displays errors if they occur.

Full Name

Configure Trap Manager

Syntax

cnftrapmgr -ip <ip_addr> -pt <portnum> -en <enabled> -tf <TrapFlag> -seq <SeqNum>

where:

-ip

indicates that an IP address follows.

ip_addr

is the IP address of the trap manager in the format nnn.nnn.nnn.nnn, where n = 0-9, and nnn < 256.

-pt

means that a port number follows.

portnum

is a port number in the range 1-n, where n is the highest port number.

-en

means that an enable flag follows.

enabled

is the action on a row: 1 = add row; 2 = delete row; and 3 = modify row.

-tf

means a trap flag follows.

TrapFlag

is the trap flag.

-seq

means a sequence number follows.

SeqNum

is the sequence number.

Related Commands

None

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example

spirit4.1.8.PXM.a > cnftrapmgr -ip 192.169.3.102 -pt 3 1 -tf 1 -seq 100

System Response

none

cnftrk

The cnftrk command lets you configure various trunk parameters. Execute this command after you have configured the interface as a routing trunk using the cnfifastrk command and activated the trunk on a node through the addtrk command.

Full Name

Configure Trunk

Syntax

Note You can execute this command for only one optional (all but -slot.port) parameter at a time.

cnftrk -slot.port slot.port [-stres <Stats Reserve> | -CcRstr <CC Restrict> | -LnTyp <Line Type> | -PassSync <yes/no> | -DrtDly <Deroute Delay> | -Fst <yes/no> |
-Fr <yes/no> | -nts <yes/no> | -ts <yes/no> | -voice <yes/no> | -cbr <yes/no> | -vbr <yes/no> |
-abr <yes/no> | -rtcost <Routing Cost> | -vpcconid <Max VPC Con IDs>]

where:

slot.port

specifies the trunk. Typically, slot is 7. The range for port is 1-n, where n is the highest numbered port on the card.

-stres

indicates the statistical reserve specification follows.

Stats Reserve

is the statistical reserve. The units of measure are cells per second, and the range is 0-maximum bandwidth of the card.

-CcRstr

indicates the specification for control plane restriction follows.

CC Restrict

activates or deactivates the control plane communication restriction. With this restriction, the switch avoids sending PAR control data over this trunk but does send control data if no other trunk is available. Enter "yes" to activate the restriction or "no" to allow PAR control communication.

-LnTyp

indicates a line type specification follows.

Line Type

is the line type. Enter "terrestrial" or "satellite."

-PassSync

indicates the enable for the trunk to pass the synchronization clock follows. Enter "yes" to enable the trunk to pass sync or "no" to disable it.

-DrtDly

indicates the deroute delay specification follows.

Deroute Delay

is the number of milliseconds the switch waits to deroute connections after a trunk failure occurs. The purpose of delaying connection deroute is that occasional, transitory trunk failures do not warrant the loss of service due to connection derouting.

-Fst

indicates the ForeSight enable status follows. Enter "yes" to indicate traffic under ForeSight control.

-Fr

indicates the presence of Frame Relay-based traffic. Type "-Fr" followed by "yes" to indicate the presence of Frame Relay-based traffic.

-nts

indicates the presence of non-timestamped traffic. Follow "-nts" with a "yes" to indicate the presence of non-timestamped traffic.

-ts

indicates the presence of timestamped traffic. Follow "-ts" with a "yes" to indicate the presence of timestamped traffic.

-voice

indicates the presence of voice traffic. Follow "-voice" with a "yes" to indicate the presence of voice traffic.

-cbr

indicates the presence of constant bit rate traffic. Follow "-cbr" with a "yes" to indicate the presence of constant bit rate traffic.

-vbr

indicates the presence of variable bit rate traffic. Follow "-vbr" with a "yes" to indicate the presence of variable bit rate traffic.

-abr

indicates the presence of available bit rate traffic. Follow "-abr" with a "yes" to indicate the presence of available bit rate traffic.

-rtcost

indicates the routing cost specification follows.

Routing_Cost

is the routing cost for this trunk.

-vpcconid

indicates the number of Virtual Path Connection IDs follows.

Max VPC Con IDs

is the number of available Virtual Path Connection IDs for this trunk.

Related Commands

addtrk, dsptrks, dsptrkcnf, dsptrkload

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 2

Example
tango1.1.8.PXM.a > cnftrk 7.1-stres 1000 -ccrstr no -lntyp s -passsync yes -drtdly 0 -fst yes -fr yes -nts yes -ts yes -voice yes -cbr yes -vbr yes -abr yes -rtcost 10 -vpcconid 255
System Response

none


cnfupcabr

The cnfupcabr command lets you configure bandwidth control parameters for ABR connections on the current AUSM. No messages appear on screen unless an error occurs.

Full Name

Configure Parameter Control for ABR

Syntax

cnfupcabr <chan_num> <enable> <pcr[0+1]> <cdvt[0+1]> <scr> <scr_police> <mbs> <clp_tag>

where:

chan_num

is a channel number in the range 16-1015.

enable

is the enable/disable for UPC: 1 = Disable, 2 = Enable.

pcr[0+1]

sets the peak cell rate for cells with CLP=0 and CLP=1 in cells per second. The actual value depends on the speed of the logical port (which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal) or an IMA E1 (clear) port). Note that the IMA port's speed is variable and depends on the number of links in the port. The range is 10-38328 cells per second.

cdvt[0+1]

is the cell delay variation [0+1]: the range is
1-250000 micro seconds.

scr

sets the sustained cell rate in cells per second. The actual value depends on the speed of the logical port (which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal) or an IMA E1 (clear) port). Note that the IMA port's speed is variable and depends on the number of links in the port. The range is 10-38328 cells per second.

scr_police

specifies the type of SCR policing: 1 = CLP[0] Cells,
2 = CLP[0+1] Cells, and 3 = no SCR policing

mbs

is the maximum burst size: the range is 1-5000 cells

clp_tag

is the enable for CLP tagging: 1 = disable, 2 = enable

Related Commands

dspcon, dspcons, cnfupccbr, cnfupcvbr

Cards on Which This Command Executes

AUSM, PXM

Attributes

Log: Yes State: Active Privilege: 1-2 (Any for PXM)

cnfupccbr

The cnfupccbr command configures a connection's bandwidth control parameters for the constant bit rate (CBR) connection type on the current AUSM. No messages appear on screen unless an error occurs.

Full Name

Configure User Parameter Control Constant Bit Rate

Syntax

cnfupccbr <chan_num> <enable/disable> <pcr[0+1]> <cdvt[0+1]> <pcr[0]> <cdvt[0]> <clp_tag>

where:

chan_num

is a channel number in the range 16-1015.

enable/disable

is the UPC enable: 1 = disable, 2 = enable.

pcr[0+1]

sets the peak cell rate for cells with CLP=0 and CLP=1 in cells per second. The actual value depends on the speed of the logical port (which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal) or an IMA E1 (clear) port). Note that the IMA port's speed is variable and depends on the number of links in the port. The range is 10-38328 cells per second.

cdvt[0+1]

is the cell delay variation tolerance for cells with CLP=0 and CLP=1. The range is 1-250000 micro seconds.

pcr

sets the peak cell rate in cells per second. The actual value depends on the speed of the logical port (which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal) or an IMA E1 (clear) port). Note that the IMA port's speed is variable and depends on the number of links in the port. The range is 10-38328 cells per second.

cdvt

is the cell delay variation tolerance for cells with CLP=0. The range is 1-250000 micro seconds.

clp_tag

is the CLP tagging enable/disable: 1 = disable, 2 = enable.

Related Commands

dspcon, dspcons, cnfupcabr, cnfupcvbr

Cards on Which This Command Executes

PXM, AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

cnfupcubr

The cnfupcubr command configures usage parameter control (upc) parameters for unspecified bit rate (ubr) on the current AUSM8 card. No messages appear on screen unless an error occurs.

Full Name

Configure User Parameter Control Unspecified Bit Rate

Syntax

cnfupcubr <chan_num> <enable> <pcr[0-1]> <cvdt[0-1]> <IngPcUtil> <clp_tag>

where:

chan_num

channel number in the range 16-1015

enable

enable or disable upc in the range 1-2, 1 = disable, 2 = enable.

pcr[0-1]

sets the peak cell rate in cells per second. The actual value depends on the speed of the logical port (which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal) or an IMA E1 (clear) port). Note that the IMA port's speed is variable and depends on the number of links in the port. The range is 10-38328 cells per second.

cvdt[0-1]

cell delay variation in range of 1-250000 microseconds

IngPcUtil

Ingress percentage utilization in the range 1-100 (0 = default)

clp_tag

CLP tag enable in the range 1-2, 1 = disable, 2 = enable

Related Commands

dspcon, dspcons, cnfupcabr, cnfupcvbr

Cards on Which This Command Executes

PXM, AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

cnfupcvbr

The cnfupcvbr command configures a channel's bandwidth control parameters for a variable bit rate (VBR) connection type on the current AUSM. No messages appear on screen unless an error occurs.

Full Name

Configure User Parameter Control Variable Bit Rate

Syntax

cnfupcvbr <chan_num> <enable> <pcr[0+1]> <cdvt[0+1]> <scr> <scr_police> <mbs> <clp_tag>

where:

chan_num

is a channel number in the range 16-1015.

enable

is the enabled/disable for UPC: 1 = Disable, 2 = Enable.

pcr

is the peak cell rate for CLP [0+1] cells. The actual value depends on the speed of the logical port (which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal) or an IMA E1 (clear) port). Note that the IMA port's speed is variable and depends on the number of links in the port. The range is 10-38328 cells per second.

cdvt

cdvt[0+1] is the cell delay variation tolerance for cells with CLP=[0+1]. The range is 1-250000 micro seconds.

scr

is the sustained cell rate: the range is 1-4670 cells per second.

scr_police

specifies the type of SCR policing: 1= CLP[0] Cells,
2 = CLP[0+1] Cells, and 3 = no SCR policing.

mbs

is the maximum burst size: the range is 1-5000 cells.

clp_tag

is the enable for CLP tagging: 1 = disable, 2 = enable.

Related Commands

dspcon, dspcons, cnfupcabr, cnfupccbr

Cards on Which This Command Executes

PXM, AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

cnfvismip

The cnfvismip command configures the VISM IP address and the SU (signaling unit) IP address on the VISM card. An IP address for each VISM is necessary for it to communicate with the SU and serves as the identifier for VoIP endpoints. Together, the VISM IP address and the local RTP port identify the bearer channel of each VoIP connection.

.Any of the above three parameters can be configured with "cnfvismip" command. It is possible to configure all of them in a single command invocation or separate invocations. Once configured, these IP addresses will be stored on the hard disk on the PXM and will be retrieved from there for subsequent re-boots of the card.

Note that no automatic mechanism exists for communicating or registering the VISM IP address to the LightSpeed unit. Therefore, you must configure the signaling unit with the IP address of each CU that the SU controls.

Full Name

Configure VISM IP Address

Syntax

cnfvismip -cuip <VISM IP address> | -mask <net mask> | -suip <SU IP address>

where:

-cuip

Indicates the IP address of the VISM follows.

VISM IP address

IP address of the VISM (CU). The format is nnn.nnn.nnn.nnn, where n = 0-9, and nnn < 256.

-mask

Indicates a network mask follows.

net mask

The network mask in the format nnn.nnn.nnn.nnn, where n = 0-9, and nnn < 256.

-suip

Indicates the IP address of the signaling unit (SU) follows.

SU IP address

IP address of the signaling unit (SU). The format is nnn.nnn.nnn.nnn, where n = 0-9, and nnn < 256.

commit

The commit command confirms copying the selected firmware file into the PXM.

Full Name

Confirm copying the firmware load

Syntax

commit <fw_load>

where:

fw_load

is the firmware file name. filename mapping of the SM card to its name on the FW directory, (CESM=sm90.fw, FRSM=sm35.fw, AUSM=sm50.fw, FRSM-VHS=sm130.fw).

Related Commands
abort, copy
Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: Any

Example
spirit4.1.8.PXM.a > commit pxm_1.0.00Ef.fw
Description

Commit to begin loading the firmware file named pxm_1.0.00Ef.fw.

System Response

none

copy

The copy command copies the selected firmware file into the PXM.

Full Name

Copy the firmware load

Syntax

copy <fw_load>

where:

fw_load

is the firmware file name.

Related Commands
abort, commit
Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > copy pxm_1.0.00Ef.fw
Description

Copy loading firmware file named pxm_1.0.00Ef.fw.

System Response

none

copychans

The copychans command copies a channel configuration to one or more channels. The purpose of this command is to create and configure multiple channels from the channel that serves as a template.

Full Name

Copy Channels

Syntax

copychans <template chan #> <start chan #> <start dlci> <# of chans>

where:

template chan #

template channel number. A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For AUSM, 16-1015

start chan #

start channel number. A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For AUSM, 16-1015

start dlci

start dlci for FRSM, start vci for AUSM

# of chans

number of channels

Related Commands

delchan, delchans

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: No State: Active Privilege: 1

copyports

The copyports command copies a port configuration to one or more ports. The purpose of this command is to create and configure multiple ports from a single port that serves as a template.

Full Name

Copy Ports

Syntax

copyports <template port #> <start port #> <start time slot> <# of ports>

where:

template port #

template port number is the number of the port to be copied

start port #

start port number is the port to be copied

start time slot

start time slot is the starting time slot in the port to be copied

# of ports

number of ports is the number of contiguous time slots to be copied

Related Commands

delport, delports

Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Active Privilege: 1

delaimgrp

This command deletes an AIMUX group.

Full Name

Delete AIMUX Group

Syntax

delaimgrp <aimux_grp>

where:

aimux_grp

AIMUX group number to be deleted (1-8)

Related Commands

addaimgrp, cnfaimgrps, dspaimgrp, dspaimgrps

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
delaimgrp 2 
Description

Delete AIMUX group 2 on the current AUSM card.

System Response

none

delcdrscprtn

The delcdrscprtn command deletes GLCNs allocated to a controller. This command applies if the card partition type is controllerBased.

Full Name

Delete Card Resource Partition

Syntax

delcdrscprtn <ctrlr_num>

where:

ctrlr_num

is the controller number: 1 for PAR/PVC, 2 for PNNI/SPVC, or 3 for TAG.

Related Commands

addcdrscprtn, cnfcdrscprtn, dspcdrscprtn

Cards on Which This Command Executes

PXM, AUSM, FRSM, CESM, VISM

Attributes

Log: Yes State: Any Privilege: Service

Example
spirit4.1.8.PXM.a > delcdrscprtn 3
Description

Delete the allotment of connections on the current card for the Tag controller.

System Response

none

delchan

Deletes a channel. After you finish this command, no messages appear on-screen unless the command cannot execute as entered.

Full Name

Delete Channel

Syntax

delchan <channel number>

where:

channel number

is the channel number. For FRSM, channel number is the DLCI. For the PXM, channel number is in the range 16-4111. For the CESM-T1E1, channel number is in the range 32-279. For the CESM-T3E3, channel number is 32.

Related Commands

dspchan, addchan, cnfchan

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: Yes State: Any Privilege: Any

delchanloop

Delete a channel loopback from the current FRSM or AUSM.

No messages appear on screen after command entry unless the command cannot execute as entered.

Full Name

Delete a channel loopback

Syntax

delchanloop <chan_num>

where:

chan_num

channel number is in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For AUSM, 16-1015

Related Commands

addchanloop, tstcon, tstdelay

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: Yes State: Active Privilege: 1-4

delchans

The delchans command deletes a range of Frame Relay or ATM channels.

Full Name

Delete Channels

Syntax

delchans <start chan #> <# of chans>

where:

start chan #

start channel number. A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For AUSM, 16-1015

# of chans

number of channels to delete

Related Commands

none

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: No State: Active Privilege: 1

delcon

Deletes a connection from an AUSM or VISM card.

No messages appear on screen after command entry unless the command cannot execute as entered.

Full Name

Delete a Connection

Syntax for Service Modules:

delcon <connection number>

where:

connection number

connection number is in the range 16-1015

Syntax for PXM:

delcon <connection id>

where:

connection id

connection id is a string in the format: PortNo.VPI.VCI

Related Commands

addcon, dspcons, dspcon

Cards on Which This Command Executes

PXM, AUSM, VISM

Attributes

Log: Yes State: Active Privilege: 1-2 (Any on PXM)

delifip

The delifip deletes a management interface.

Full Name

Delete a Management Interface

Syntax

delifip <Interface>

where:

Interface

Interface is the number 26, 28, or 37:

· 26 for Ethernet

· 28 for SLIP

· 37 for ATM

Related Commands

cnfifip, dspifip

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Any Privilege: SuperUser

Example
spirit1.1.8.PXM.a > delifip 37
Description

Delete the ATM interface (indicated by the number 37).

System Response

None

dellink

The dellink command deletes a link between a T1 line within a T3 line on a SRM-3T3 card and a slot and line number on a service module.

Full Name

Delete Link

Syntax

dellink <T3 line number> <T1 line number>

where:

T3 line number

SRM-3T3 T3 line number in the format slot.port where slot is either 15 or 31, and line is in the range 1 to n. (range 1-3)

T1 line number

starting T1 line number within the T3 line (range 1-28)

Related Commands

dsplink, addlink

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
spirit1.1.8.PXM.a > dellink 15.1 1
 
Description

Delete the link between the first T3 line on the SRM-T3 in slot 15 and T1 line 1.

System Response

None

delln

The delln command deletes a line from the current card.

Full Name

Delete Line

Syntax

For a T1 or E1 line:

delln <LineNum>

For a SONET, T3, or E3 line:

delln <-ds3 | -e3 | -sonet> <LineNum>

where:

LineNum

is the number of the line to deactivate on the current card. SRM-3T3 T3 line number is in the format slot.port where slot is either 7, 15 or 31, and line is in the range 1 to n. (range 1-3)

-ds3

indicates a T3 line.

-e3

indicates an E3 line.

-sonet

indicates a SONET line.

Related Commands

dspln, addln, cnfln

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: Yes State: Active Privilege: 1

Example

delln 4

Description

Delete line 4 from the current card.

System Response

None. No system response unless an error occurs.

dellnloop

This command removes a T1 or E1 line loopback state for the current card.

Full Name

Delete Line Loop

Syntax

dellnloop -ds3 | -e3 | -sonet <line number>

where:

line number

for ds3 or e3, line number is in the format slot.port where slot is either 7, 15 or 31, and line is in the range 1 to n.

for sonet, line number is in the format slot.port where slot is 7, and line is in the range 1 to n.

value from 1-8 used for FRSM, VISM, AUSM, and CESM

Related Commands

addlnloop

Cards on Which This Command Executes

PXM, AUSM, FRSM, CESM, VISM

Attributes

Log: No (Yes PXM) State: Active Privilege: -1 (Service) (Any on PXM)

dellnsfmaimgrp

This command deletes lines from an existing AIMUX group.

Full Name

Delete Lines From an AIM Group

Syntax

dellnsfmaimgrp <aimux_grp> <list_of_lines>

where:

aimux_grp

AIMUX group from which lines should be deleted (1-8)

list_of_lines

list of lines to be deleted from the AIMUX group separated by dots

Related Commands

addlns2aimgrp

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit1.1.8.PXM.a > dellnsfmaimgrp 2 3.5 
Description

Delete lines 3 and 5 from AIMUX group 2.

System Response

None. No system response unless an error occurs.

delport

The delport command deletes a port from an FRSM, a PXM, or a CESM.

No messages appear on screen with successful completion of this command.

Full Name

Delete Port

Syntax

delport <port-number>

where:

port-number

port number of the port to be deleted

Related Commands

addport, cnfport, dspport, dspports

Cards on Which This Command Executes

PXM, FRSM, CESM

Attributes

Log: Yes State: Active Privilege: 1

delports

The delports command deletes a specified number of contiguous port configurations.

No messages appear on screen with successful completion of this command.

Full Name

Delete Ports

Syntax

delports <start port #> <# of ports>

where:

start port #

start port number is the port to be deleted

# of ports

number of ports is the number of contiguous time slots to be deleted

Related Commands

copyports

Cards on Which This Command Executes

FRSM, CESM

Attributes

Log: No State: Active Privilege: 1

delred

The delred command deletes a redundancy link for the specified primary card slot.

Full Name

Delete Redundancy

Syntax

delred <redPrimarySlotNumber>

where:

redPrimarySlotNumber

slot number of the slot containing the primary card of the card pair. The range is 1-6, 9-14, 17-22, and 25-30.

Related Commands

dspred, addred

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

delrscprtn

The delrscprtn command deletes a resource partition. Refer to the description of addrscprtn for information on resource partitions.

Full Name

Delete Resource Partition

Syntax

delrscprtn <if_num> <ctrlr_num>

where:

if_num

Interface Number---a number between 1 and 32

ctrlr_num

Controller Number---1:PAR, 2:PNNI, or 3:TAG

Related Commands

addrscprtn

Cards on Which This Command Executes

PXM, FRSM

Attributes

Log: No State: Any Privilege: Any

delslotlink

The delslotlink command deletes SRM-3T3 link information for a specified slot.

Full Name

Delete Slot Link

Syntax

delslotlink <slot number> <line number>

where:

slot number

Slot number for which the link is to be deleted.

line number

Line number for which the link is to be deleted. Use 0 to unlink all lines, or select a number in the range 1 through n, where n is the highest number line on the card in the chosen slot.

Related Commands

dspslotlink

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

deltrapmgr

Delete the specified trap manager associated with the specified IP address.

Full Name

Delete Trap Manager

Syntax

deltrapmgr <ipaddr>

where:

ipaddr

IP address of the trap manager to delete. The format is nnn.nnn.nnn.nnn, where n = 0-9, and nnn < 256.

Related Commands

addtrapmgr, dsptrapmgr, dsptrapmgrs

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

deltrk

Deactivates a trunk.

Full Name

Delete Trunk

Syntax

deltrk <trunk number>

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 1

deluser

Delete a user from the list of users on the MGX 8850 node. The system does not allow you to delete a user with a privilege level higher than the level at which you execute the command. For example, if the current user privilege is 2, you cannot delete a user at level 1. No screen output appears unless an error occurs.

Full Name

Delete User

Syntax

deluser <user ID>

where:

user ID

is the ID of the user.

Related Commands

dspusers, adduser

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 1-5

dncon

The dncon command temporarily downs a connection. The typical purpose of dncon is some form of operational modification or troubleshooting. You can subsequently up the connection with upcon.

Full Name

Down Connection

Syntax

dncon <slot >.<port>.<vpi>.<vci>

where the connection specification has the format slot.port.vpi.vci, where slot is within the ranges 1-6, 9-14, 17-22, or 25-30, and port is a value in the range 1-n, where n is the highest numbered port on the card.

Related Commands

upcon

Cards on Which This Command Executes

AUSM, VISM, CESM

Attributes

Log: No State: Active Privilege: 2

dnif

The dnif command deactivates the specified broadband interface. Note that, for a user-port, you must remove all UNI channels on the interface before you deactivate the port.

Full Name

Down Interface

Syntax

dnif <if_num>

where:

if_num

is the interface number in the range 1-32.

Related Commands

cnfif, dspif, upif

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 1

dnport

The dnport command deactivates a port. No messages appear on screen unless an error occurs.

Full Name

Down Port

Syntax

dnport <PortNum>

where:

PortNum

is the number of the port. The range is 1-n, where n is the highest port number on the card.

Related Commands

upport

Cards on Which This Command Executes

AUSM, FRSM

Attributes

Log: No State: Active Privilege: 1

dspaimgrp

This command displays detailed status and configuration information for a specified AIMUX group.

Full Name

Display AIM Group Status and Configuration

Syntax

dspaimgrp <aimux_grp>

where:

aimux_grp

AIMUX group number for the group to be displayed (1-8)

Related Commands

addaimgrp, delaimgrp, cnfaimgrps, dspaimgrps

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.19.AUSM8.a > dspaimgrp 1
Description

Display all the detailed status and configuration information for AIMUX group 1 on the current card.

System Response

   IMA Group number                 : 1
   Port type                        : NNI
   Lines configured                 : 1.2.3
   Enable                           : Enabled
   IMA Port state                   : Sig. Failure
   IMA Group Ne state               : Startup
   PortSpeed (cells/sec)            : 13470
   GroupTxAvailCellRate (cells/sec) : 0
   ImaGroupTxFrameLength(cells)     : 128
   LcpDelayTolerance (IMA frames)   : 1
   ReadPtrWrPtrDiff  (cells)        : 4
   Minimun number of links          : 2
   MaxTolerableDiffDelay (msec)     : 200
   Lines Present                    :
   ImaGroupRxImaId                  : 0x100
   ImaGroupTxImaId                  : 0x0
   Observed Diff delay (msec)       : 0
   Clock Mode                       : CTC
   GroupAlpha                       : 2
   GroupBeta                        : 2
   GroupGamma                       : 1
 
Type <CR> to continue, Q<CR> to stop:
 
 
   GroupConfiguration               : 1
   IMAGrp Failure status            : Ne StartUp
   Timing reference link            : 1
 
 
Syntax : dspimagrp (or dspaimgrp) "imagroup_number"
         IMA group number -- value ranging from 1 to 8
 

dspaimgrpcnt

This command displays all the AIMUX related counters for a line in an AIMUX group.

Full Name

Display AIM Group Count

Syntax

dspaimgrpcnt <aimux_grp>

where:

aimux_grp

AIMUX group number

Related Commands

clraimgrpcnt

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.19.AUSM8.a > dspaimgrpcnt 1
Description

Display all the AIMUX related counters for AIMUX group 1 on the current card.

System Response

  IMA Group number:                           1
  Ne Number of failures                   :   0
 
 
Syntax : dspimagrpcnt (or dspaimgrpcnt) imagroup
         IMA group number -- value ranging from 1 to 8

dspaimgrps

This command displays the status and configuration information for all current AIMUX groups.

Full Name

Display Status and Configuration of All AIM Groups

Syntax

dspaimgrps

Related Commands

addaimgrp, delaimgrp, cnfaimgrps, dspaimgrp

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
spirit.1.19.AUSM8.a > dspaimgrps
Description

Display the status and configuration information for all AIMUX groups on the current card.

System Response
 List of IMA groups:
 ===================
 
ImaGrp PortType Speed  Lines configured  Lines present  Tol Diff  Port State
                                                        Delay(ms)
------ -------- -----  ----------------  -------------  --------- ----------
 19.1   NNI     13470  1.2.3                             200      Sig. Failure
 
  NextPortNumAvailable:  6
 
Syntax : dspimagrps (or dspaimgrps)
 

dspaimlncnt

This command displays all the AIMUX line counters for the specified line in an IMA trunk.

Full Name

Display AIM (or Display IMA) Line Count

Syntax

dspaimlncnt <aimux_grp> <line_num>

where:

aimux_grp

AIMUX group number. Range is 1 to 8.

line_num

AIMUX line number. Range is 1 to 8.

Related Commands

clraimlncnt, clrimalncnt, dspimalncnt

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
spirit.1.19.AUSM8.a > dspaimlncnt 1 1
Description

Display the line counters for line 1 of IMA group 1.

System Response
   IMA group number                : 1
   Line number                     : 1
   Acp Cells Received              : 0
   Acp Errored Cells Recvd         : 0
   Port changed from LDS           : 0
   # HEC errored cells             : 0
   # HEC errored seconds           : 0
   # Severely HEC errored seconds  : 0
 
Syntax : dspimalncnt (or dspaimlncnt) imagroup linenum
         IMA group number -- value ranging from 1 to 8
         line number -- value ranging from 1 to 8

dspalm

The dspalm command displays the alarms for a line.

Full Name

Display Alarms for a Line

Syntax

dspalm -ds1 <LineNum> | -ds3 <LineNum> | -e3 <LineNum> | -plcp <PCLPNum> | -sonet <LineNum>

where, for

-ds1, LineNum is in the range 1-8 on the FRSM, VISM, AUSM or CESM.

-ds3, LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3.

-e3, LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3.

-plcp, PLCPNum = LineNum; LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3

-sonet, LineNum = slot.line, where slot is 7, and line is in the range of 1 to 4 for OC-3 and is just 1 for OC-12

Related Commands

clralm, dspalms

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Active Privilege: Any

Example 1
spirit.1.7.PXM.a > dspalm -ds3 7.2
Description

On a PXM, display alarms on the T3 line number 2.

System Response
spirit.1.7.PXM.a > dspalm -ds3 7.2
  LineNum:                   2
  LineAlarmState:            No Alarms
  LineStatisticalAlarmState: No Statistical Alarms         
Example 2

spirit.1.7.PXM.a > dspalm -sonet 7.1

Description

On a PXM, display alarms on OC-3 line 1.

System Response
 LineNum:                       1
 SectionCurrentStatus:          Clear
 LineCurrentStatus:             Clear
 PathCurrentStatus:             Clear
 SectionStatAlarmStatus:        Clear
 LineStatAlarmStatus:           Clear
 PathStatAlarmStatus:           Clear
Example 3
wilco.1.7.PXM.a > dspalm -e3 7.1
Description

On a PXM, display alarms on E3 line 1.

System Response
  LineNum:                   1
  LineAlarmState:            XmtRAI,RcvLOS
  LineStatisticalAlarmState: UAS15minAlarm,UAS24hrAlarm
 
Example 4
spirit.1.19.AUSM8.a > dspalm -ds1 1
Description

On an AUSM, display alarms on T1 line 1.

System Response
  LineNum:                   1
  LineAlarmState:            Alarm(s) On --
                                RcvLOS
  LineStatisticalAlarmState: Alarm(s) On --
                                UAS15minAlarm
                                UAS24hrAlarm
Example 5
spirit.1.5.VISM8.a > dspalm -ds1 1
Description

Display alarms on line 1 on the current card (a VISM).

System Response
  
  LineNum:                   1
  LineAlarmState:            No Alarms
  LineStatisticalAlarmState: No Statistical Alarms
 
 
spirit.1.5.VISM8.a >

dspalmcnf

The dspalmcnf command displays the threshold information about the alarm statistics being collected.

Full Name

Display Alarm Configuration

Syntax

dspalmcnf -ds1 <LineNum> | -ds3 <LineNum> | -e3 <LineNum> | -plcp <PCLPNum> | -sonet <LineNum>

where, for

-ds1, LineNum is in the range 1-8 on the FRSM, VISM, AUSM or CESM.

-ds3, LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3.

-e3, LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3.

-plcp, PLCPNum = LineNum; LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3

-sonet, LineNum = slot.line, where slot is 7, and line is in the range of 1 to 4 for OC-3 and is just 1 for OC-12

Related Commands

dspalm, dspalms

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Active Privilege: Any

Example 1

spirit.1.17.FRSM.a > dspalmcnf -ds1 17.4

Description

Display the alarm configuration for line 4 on the current FRSM (slot 17 in this example).

System Response
         Severity   AlarmUpCount  AlarmDnCount  AlarmThreshold
  Line  Red / RAIS    NE / FE       NE / FE       NE  /  FE
  ---- ----- -----  ----- -----   ----- -----    ----- -----
  17.4  Major/Minor      6/1        1500/6            1/1500
Example 2

spirit.1.7.PXM.a > dspalmcnf -ds3 7.1

Description

Display the alarm configuration for the current PXM.

System Response
  LineNum:                  1
  RedSeverity:              Major
  RAISeverity:              Minor
  NEAlarmUpCount:           6
  NEAlarmDnCount:           1
  NEAlarmThreshold:         150
  FEAlarmUpCount:           6
  FEAlarmDnCount:           1
  FEAlarmThreshold:         150
  StatisticalAlarmSeverity: Minor
  LCV15minThreshold:        3870
  LCV24hrThreshold:         38650
  LES15minThreshold:        86
  LES24hrThreshold:         864     PSES24hrThreshold:        40
  LSES15minThreshold:       4       SEFS15minThreshold:       120
  LSES24hrThreshold:        40      SEFS24hrThreshold:        1200
  PCV15minThreshold:        382     AISS15minThreshold:       120
  PCV24hrThreshold:         3820    AISS24hrThreshold:        1200
  PES15minThreshold:        86      UAS15minThreshold:        120
  PES24hrThreshold:         864     UAS24hrThreshold:         1200
  PSES15minThreshold:       4
 
Example 3
spirit.1.19.AUSM8.a > dspalmcnf -ds1 1
Description

Display the alarm configuration on the current AUSM for E1 line 1.

System Response
 
  LineNum:                  1
  RedSeverity:              Major
  RAISeverity:              Minor
  NEAlarmUpCount:           6
  NEAlarmDnCount:           6
  NEAlarmThreshold:         1
  FEAlarmUpCount:           1
  FEAlarmDnCount:           1500
  FEAlarmThreshold:         1500
  StatisticalAlarmSeverity: Minor
  lCV15minThreshold:        14
  lCV24hrThreshold:         134
  lES15minThreshold:        12
  lES24hrThreshold:         121
  lSES15minThreshold:       10
  lSES24hrThreshold:        100
  cRC15minThreshold:        14
  cRC24hrThreshold:         134
  cRCES15minThreshold:      12
  cRCES24hrThreshold:       121
  cRCSES15minThreshold:     10
  cRCSES24hrThreshold:      100
  SEFS15minThreshold:       2
  SEFS24hrThreshold:        17
  AISS15minThreshold:       2
  AISS24hrThreshold:        17
  UAS15minThreshold:        10
  UAS24hrThreshold:         10
 
 
spirit.1.19.AUSM8.a >
 
Example 4
spirit.1.5.VISM8.a > dspalmcnf -ds1 1
Description

Display the alarm configuration on the current VISM for E1 line 1.

System Response
         Severity   AlarmUpCount  AlarmDnCount  AlarmThreshold
  Line  Red / RAIS    NE / FE       NE / FE       NE  /  FE
  ---- ----- -----  ----- -----   ----- -----    ----- -----
  5.1  Major/Minor      6/6           1/1         1500/1500
 
 spirit.1.5.VISM8.a >
Example 5
 
spirit.1.1.VHS2T3.a > dspalmcnf -ds3 1
Description

Display the alarm configuration on the current FRSM-2T3 for line 1.

System Response
 
  LineNum:                  1
  RedSeverity:              Major
  RAISeverity:              Minor
  NEAlarmUpCount:           4
  NEAlarmDnCount:           3
  NEAlarmThreshold:         1200
  FEAlarmUpCount:           4
  FEAlarmDnCount:           3
  FEAlarmThreshold:         1200
  StatisticalAlarmSeverity: Minor
  LCV15minThreshold:        3870
  LCV24hrThreshold:         38650
  LES15minThreshold:        86
  LES24hrThreshold:         864
  LSES15minThreshold:       4
  LSES24hrThreshold:        40
  PCV15minThreshold:        382
  PCV24hrThreshold:         3820
  PES15minThreshold:        86
  PES24hrThreshold:         864
  PSES15minThreshold:       4
  PSES24hrThreshold:        40
  CCV15minThreshold:        382
  CCV24hrThreshold:         3820
  CES15minThreshhold:       86
  CES24hrThreshold:         864
  CSES15minThreshold:       4
  CSES24hrThreshold:        40
  SEFS15minThreshold:       120
  SEFS24hrThreshold:        1200
  AISS15minThreshold:       120
  AISS24hrThreshold:        1200
  UAS15minThreshold:        120
  UAS24hrThreshold:         1200
 
 
spirit.1.1.VHS2T3.a >

dspalmcnt

The dspalmcnt command displays the alarm counters and statistics.

Full Name

Display Alarm Counters

Syntax

dspalmcnt -ds1 <LineNum> | -ds3 <LineNum> | -e3 <LineNum> | -plcp <PCLPNum> | -sonet <LineNum>

where, for

-ds1, LineNum is in the range 1-8 on the FRSM, VISM, AUSM or CESM.

-ds3, LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3.

-e3, LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3.

-plcp, PLCPNum = LineNum; LineNum = slot.line, where slot is either 7, 15, or 31, and line is 1-3

-sonet, LineNum = slot.line, where slot is 7, and line is in the range of 1 to 4 for OC-3 and is just 1 for OC-12

Related Commands

clralmcnt, clralmcnts

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Active Privilege: Any

Example 1

wilco.1.7.PXM.a > dspalmcnt -ds3 7.1

Description

Display alarm count for line 1 (T3) of a PXM.

System Response
spirit.1.7.PXM.a > dspalmcnt -ds3 7.1
  LineNum:             1
  LCVCurrent:          0
  LCVLast15minBucket:  0
  LCVLast24hrBucket:   0
  LESCurrent:          0
  LESLast15minBucket:  0
  LESLast24hrBucket:   0
  LSESCurrent:         0
  LSESLast15minBucket: 0
  LSESLast24hrBucket:  0
  PCVCurrent:          0
  PCVLast15minBucket:  0
  PCVLast24hrBucket:   0
  PESCurrent:          0
  PESLast15minBucket:  0
  PESLast24hrBucket:   0
  PSESCurrent:         0
  PSESLast15minBucket: 0
  PSESLast24hrBucket:  0
  SEFSCurrent:         0
  SEFSLast15minBucket: 0
  SEFSLast24hrBucket:  0
  AISSCurrent:         0
  AISSLast15minBucket: 0
  AISSLast24hrBucket:  0
  UASCurrent:          0
  UASLast15minBucket:  0
  UASLast24hrBucket:   0
  PercentEFS:          0
  RcvLOSCount:         1
  RcvOOFCount:         0
  RcvRAICount:         0
  RcvCCVCount:         0
  RcvFECount:          0
spirit.1.7.PXM.a >              
Example 2

spirit.1.11.FRSM.a > dspalmcnt -ds1 1

Description

Display alarms and counters for line 1 on the current FRSM.

System Response
  Line  RcvLOSCount  RcvOOFCount  RcvRAICount  RcvFECount
  ----  -----------  -----------  -----------  ----------
  11.1            1            2           17           2
Example 3
spirit11.1.7.PXM.a > dspalmcnt -sonet 7.1
Description

Display alarms and counters for line 1 on the PXM with OC3.

System Response
  SonetLineNum:                         1
 
  SectionCurrentValidFlag:              valid
  SectionCurrent15minTimeElapsed:       429s
  SectionCurrentESs:                    0
  SectionCurrentSESs:                   0
  SectionCurrentSEFSs:                  0
  SectionCurrentCVs:                    0
  SectionCurrentDayValidFlag:           valid
  SectionCurrentDayESs:                 100
  SectionCurrentDaySESs:                100
  SectionCurrentDaySEFSs:               100
  SectionCurrentDayCVs:                 5149776
  SectionCounterLOSs:                   2
  SectionCounterLOFs:                   2
  LineCurrentValidFlag:                 valid
  LineCurrent15minTimeElapsed:          429s
  LineCurrentESs:                       0
  LineCurrentSESs:                      0
  LineCurrentCVs:                       0
  LineCurrentUASs:                      0
  FarEndLineCurrentValidFlag:           valid
  FarEndLineCurrent15minTimeElapsed:    429s
  FarEndLineCurrentESs:                 0
  FarEndLineCurrentSESs:                0
  FarEndLineCurrentCVs:                 0
  FarEndLineCurrentFCs:                 0
  FarEndLineCurrentUASs:                0
  FarEndLineCurrentDayValidFlag:        valid
  FarEndLineCurrentDayESs:              2
  FarEndLineCurrentDaySESs:             2
  FarEndLineCurrentDayCVs:              46
  FarEndLineCurrentDayFCs:              0
  FarEndLineCurrentDaySEFSs:            0
  LineCurrentDayValidFlag:              valid
  LineCurrentDayESs:                    100
  LineCurrentDaySESs:                   100
  LineCurrentDayCVs:                    100
  LineCurrentDaySEFSs:                  0
  LineCounterAISs:                      2
  LineCounterRFIs:                      0
  PathCurrentValidFlag:                 valid
  PathCurrent15minTimeElapsed:          429s
  PathCurrentESs:                       0
 
Example 4
spirit11.1.7.PXM.a > dspalmcnt -e3 7.1
Description

Display alarms and counters for line 1 (E3) on the PXM.

System Response
  LineNum:             1
  LCVCurrent:          0
  LCVLast15minBucket:  0
  LCVLast24hrBucket:   0
  LESCurrent:          0
  LESLast15minBucket:  0
  LESLast24hrBucket:   0
  LSESCurrent:         0
  LSESLast15minBucket: 0
  LSESLast24hrBucket:  0
  SEFSCurrent:         0
  SEFSLast15minBucket: 0
  SEFSLast24hrBucket:  0
  AISSCurrent:         0
  AISSLast15minBucket: 0
  AISSLast24hrBucket:  0
  UASCurrent:          572
  UASLast15minBucket:  900
  UASLast24hrBucket:   4496
  BIP8CVCurrent:       0
  BIP8CV15MinBucket:   0
  BIP8CV24HrBucket:    0
  BIP8ESCurrent:       0
  BIP8ES15MinBucket:   0
  BIP8ES24HrBucket:    0
  BIP8SESCurrent:      0
  BIP8SES15MinBucket:  0
  BIP8SES24HrBucket:   0
  PercentEFS:          100
  RcvLOSCount:         0
  RcvOOFCount:         0
  RcvRAICount:         0
  RcvCCVCount:         0
  RcvFECount:          0
 
 
Example 5
spirit.1.5.VISM8.a > dspalmcnt -ds1 1
Description

Display alarms and counters for line 1 on the VISM.

System Response
 
 
  Line  RcvLOSCount  RcvOOFCount  RcvRAICount  RcvFECount
  ----  -----------  -----------  -----------  ----------
  5.1             0            0            0        4095
 
 
spirit.1.5.VISM8.a >
Example 5
 
spirit.1.1.VHS2T3.a > dspalmcnt -ds3 1
Description

Display alarms and counters for line 1 on the FRSM-2T3.

System Response
 
 
  LineNum:             1
  LCVCurrent:          0
  LCVLast15minBucket:  0
  LCVLast24hrBucket:   0
  LESCurrent:          0
  LESLast15minBucket:  0
  LESLast24hrBucket:   0
  LSESCurrent:         0
  LSESLast15minBucket: 0
  LSESLast24hrBucket:  0
  PCVCurrent:          0
  PCVLast15minBucket:  0
  PCVLast24hrBucket:   0
  PESCurrent:          0
  PESLast15minBucket:  0
  PESLast24hrBucket:   0
  PSESCurrent:         0
  PSESLast15minBucket: 0
  PSESLast24hrBucket:  0
  CCVCurrent:          0
  CCVLast15minBucket:  0
  CCVLast24hrBucket:   0
  CESCurrent:          0
  CESLast15minBucket:  0
  CESLast24hrBucket:   0
  CSESCurrent:         0
  CSESLast15minBucket: 0
  CSESLast24hrBucket:  0
 
Type <CR> to continue, Q<CR> to stop:
 
  SEFSCurrent:         0
  SEFSLast15minBucket: 0
  SEFSLast24hrBucket:  0
  AISSCurrent:         0
  AISSLast15minBucket: 0
  AISSLast24hrBucket:  0
  UASCurrent:          0
  UASLast15minBucket:  0
  UASLast24hrBucket:   0
  PercentEFS:          0
  RcvLOSCount:         0
  RcvOOFCount:         0
  RcvRAICount:         0
  RcvCCVCount:         0
  RcvFECount:          0
 
 
spirit.1.1.VHS2T3.a >

dspalms

The dspalms command displays all alarms for the selected linetype on the card.

Full Name

Display all Alarms on a Card

Syntax

dspalms <lineType>

where:

lineType

The line type can be -ds1 on the T1 or E1 lines or ds3, e3, sonet, or plcp on the other lines (note the absence of a dash for ds3, e3, sonet, or plcp).

Related Commands

dspalm

Cards on Which This Command Executes

PXM, FRSM, AUSM, SRM-3T3, CESM, VISM

Attributes

Log: No State: Active Privilege: Any

Example 1

spirit.1.17.FRSM.a > dspalms -ds1

Description

Display alarms on the current FRSM (slot 17, in this case).

System Response
  Line  AlarmState   StatisticalAlarmState
  ----  -----------  ---------------------
  17.1  Alarm(s) On  No Statistical Alarms
  17.2  No Alarms    No Statistical Alarms
  17.3  No Alarms    No Statistical Alarms
  17.4  No Alarms    No Statistical Alarms
  17.5  Alarm(s) On  No Statistical Alarms
  17.6  No Alarms    No Statistical Alarms
  17.7  No Alarms    No Statistical Alarms
  17.8  No Alarms    No Statistical Alarms
Example 2
wilco.1.7.PXM.a > dspalms e3 7
Description

Display alarms on the 2 E3 lines on the current card (a PXM).

System Response
Line :  1
   AlarmState            : XmtRAI,RcvLOS
   StatisticalAlarmState : UAS15minAlarm,UAS24hrAlarm
Line :  2
   AlarmState            : No Alarms
   StatisticalAlarmState : No Statistical Alarms
Example 3
spirit.1.5.VISM8.a > dspalms -ds1
Description

Display alarms on the 3 E1 lines on the current card (a VISM).

System Response
 
 
  Line  AlarmState   StatisticalAlarmState
  ----  -----------  ---------------------
  5.1   No Alarms    No Statistical Alarms
  5.2   No Alarms    No Statistical Alarms
  5.3   No Alarms    No Statistical Alarms
Example 4
spirit.1.1.VHS2T3.a > dspalms -ds3
Description

Display alarms on the 2 T3 lines on the current card (an FRSM-2T3).

 
  Line  AlarmState   StatisticalAlarmState
  ----  -----------  ---------------------
  1.1   No Alarms    No Statistical Alarms
  1.2   No Alarms    No Statistical Alarms
 
 
spirit.1.1.VHS2T3.a >

dspatmlncnf

The dspatmlncnf command shows the cell header configuration for the line. The display indicates NNI or UNI cell headers. The configuration is the result of cnfatmln execution. This command applies to stand-alone configurations of the MGX 8850 switch.

Full Name

Display ATM Line Configuration

Syntax

dspatmlncnf <line_num>

where line_num is in the range 1-n and n is the highest line number on the card.

Related Commands

cnfatmln, clratmlncnt

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
wilco.1.7.PXM.a > dspatmlncnf 2
Description

Display the line configuration for line 2 of PXM.

System Response
 
 lineNum   atmLineInterfaceFormat
----------------------------------
    2             NNI

dspatmlncnt

The dspatmlncnt command shows the ATM cell counters for the specified line. The display shows the total number of cells received, the total number of cells transmitted, and the number of cells received with HEC errors. The configuration is the result of cnfatmlncnt execution. This command applies to stand-alone configurations of the MGX 8850 switch.

Full Name

Display ATM Line Counters

Syntax

dspatmlncnt <line_num>

where line_num is in the range 1-n and n is the highest line number on the card.

Related Commands

cnfatmln, clratmlncnt, clratmlncnts

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
wilco.1.7.PXM.a > dspatmlncnt 1
Description

Display the ATM line counters (total cells received, total cells transmitted, and number of cells received with HEC errors) for line 1 of the PXM.

System Response
Line Number            :          1 
Total Rcvd. Cells      :    5214310 
Total Xmtd. Cells      :     368687 
Rcvd. HEC Error Cells  :          0 
 

dspcd

This command displays characteristics of the current card's hardware and firmware and information on its status. Card characteristics include serial number and hardware and firmware revision levels. Status may include the reason for the last reset (FunctionModuleResetReason) and state of the integrated alarm (cardIntegratedAlarm), which can be useful in debugging the card or the
MGX 8850 switch, respectively. Some of the information is common to the version command display, but version shows boot code version in bold.

Full Name

Display Card

Syntax

dspcd [slot number]

where:

slot number

Not needed when logged into the service modules. While logged into the PXM, slot number is the slot number of the service module you want to view: the range is 15, 16, 31-32.

Related Commands

dspcds, version

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1

dspcd on the current AUSM-8T1

System Response
  ModuleSlotNumber:          14
  FunctionModuleState:       Active
  FunctionModuleType:        AUSM-8T1
  FunctionModuleSerialNum:   FNTYPE
  FunctionModuleHWRev:       fk
  FunctionModuleFWRev:       model-A 2.0.00
  FunctionModuleResetReason: Reset by PXM from PIO
  LineModuleType:            LM-DB15-8T1
  LineModuleState:           Present
  mibVersionNumber:          4
  configChangeTypeBitMap:    CardCnfChng, LineCnfChng
  cardIntegratedAlarm:       Minor
  cardMinorAlarmBitMap:      Channel failure
          
Example 2

dspcd on the current PXM

System Response
    ModuleSlotNumber:          7
    FunctionModuleState:       Active
    FunctionModuleType:        PXM1-T3E3
    FunctionModuleSerialNum:   ABCDEFGHIJK
    FunctionModuleHWRev:       A0
    FunctionModuleFWRev:       1.0.00ap
    FunctionModuleResetReason: Reset From Shell
    LineModuleType:            Missing
    LineModuleState:           Present
    SecondaryLineModuleType:   LM-BNC-2T3
    SecondaryLineModuleState:  Present
    mibVersionNumber:          0
    configChangeTypeBitMap:    No changes
    cardIntegratedAlarm:
Example 3

dspcd on the current FRSM-8T1

System Response
  ModuleSlotNumber:          3
  FunctionModuleState:       Active
  FunctionModuleType:        FRSM-8T1
  FunctionModuleSerialNum:   622758
  FunctionModuleHWRev:       bb
  FunctionModuleFWRev:       5.0.00ak
  FunctionModuleResetReason: Power reset
  LineModuleType:            LM-RJ48-8T1
  LineModuleState:           Present
  mibVersionNumber:          20
  configChangeTypeBitMap:    CardCnfChng, LineCnfChng
  cardIntegratedAlarm:       Clear
  fab number:                282069-01                  
 
Example 4

dspcd on the current FRSM-2CT3

System Response
  ModuleSlotNumber:          3
  FunctionModuleState:       Active
  FunctionModuleType:        FRSM-2CT3
  FunctionModuleSerialNum:   CAB024804K8
  FunctionModuleHWRev:       ex
  FunctionModuleFWRev:       5.0.00_11Jan99_1_tti
  FunctionModuleResetReason: Reset by ASC from Cell Bus
  LineModuleType:            LM-BNC-2T3
  LineModuleState:           Present
  mibVersionNumber:          20
  configChangeTypeBitMap:    CardCnfChng, LineCnfChng
  cardIntegratedAlarm:       Clear
  pcb part no-(800 level):   800-02910-04
  pcb part no-(73 level):    73-02265-04
 
wilco.1.3.VHS2CT3.a >
 
Example 5

dspcd on the current FRSM-8E1

System Response
  ModuleSlotNumber:          3
  FunctionModuleState:       Active
  FunctionModuleType:        FRSM-8E1
  FunctionModuleSerialNum:   782908
  FunctionModuleHWRev:       ab
  FunctionModuleFWRev:       5.0.00_21Dec98
  FunctionModuleResetReason: Power reset
  LineModuleType:            LM-RJ48-8E1
  LineModuleState:           Present
  mibVersionNumber:          20
  configChangeTypeBitMap:    CardCnfChng, LineCnfChng
  cardIntegratedAlarm:       Major
  cardMajorAlarmBitMap:      Line Alarm
  cardMinorAlarmBitMap:      Channel failure
  fab number:                28-2069-02          
 
Example 6

dspcd on the current CESM-8T1

System Response
  ModuleSlotNumber:          1 
  FunctionModuleState:       Active 
  FunctionModuleType:        CESM-8T1 
  FunctionModuleSerialNum:   786327 
  FunctionModuleHWRev:       ab 
  FunctionModuleFWRev:        5.0.00bq 
  FunctionModuleResetReason: Reset by ASC from Cell Bus 
  LineModuleType:            LM-RJ48-8T1 
  LineModuleState:           Present 
  mibVersionNumber:          20 
  configChangeTypeBitMap:    CardCnfChng, LineCnfChng 
  cardIntegratedAlarm:       Major 
  cardMajorAlarmBitMap:      Line Alarm 
  cardMinorAlarmBitMap:      Channel failure 
 
  fab number:                28-2199-02 
Example 7

dspcd on the current VISM-8E1

  
spirit.1.5.VISM8.a > dspcd
 
System Response
 
  ModuleSlotNumber:          5
  FunctionModuleState:       Active
  FunctionModuleType:        VISM-8E1
  FunctionModuleSerialNum:   CAB0246014W
  FunctionModuleHWRev:       0.0
  FunctionModuleFWRev:       rangar
  FunctionModuleResetReason: Power reset
  LineModuleType:            LM-RJ48-8E1
  LineModuleState:           Present
  mibVersionNumber:          20
  configChangeTypeBitMap:    CardCnfChng, LineCnfChng
  cardIntegratedAlarm:       Clear
  pcb part no - (800 level): 800-04399-01
  pcb part no - (73 level):  73-03618-01
  Fab Part no - (28 level):  28-02791-01
  PCB Revision:              05
 
  Daughter Card Information:
  Daughter Card Serial Number: CAB024601FU
  pcb part no - (73 level):    73-03722-01
  Fab Part no - (28 level):    28-02905-01
  PCB Revision:                02
 
spirit.1.5.VISM8.a >
Example 8

dspcd on the current PXM (viewing the SRM-T3E3 in slot 15).

 
tinky.1.7.PXM.a > dspcd 15
 
System Response
    ModuleSlotNumber:          15
    FunctionModuleState:       Active
    FunctionModuleType:        SRM-3T3
    FunctionModuleSerialNum:   785324
    FunctionModuleHWRev:       be
    FunctionModuleFWRev:       1.0.00
    FunctionModuleResetReason: Reset From Shell
    LineModuleType:            LM-SRM-3T3
    LineModuleState:           Present
    SecondaryLineModuleType:   Missing
    SecondaryLineModuleState:  Invalid
    mibVersionNumber:          0.0.06
    configChangeTypeBitMap:    No changes
    cardIntegratedAlarm:       Clear
    cardMajorAlarmBitMap:      Clear
    cardMinorAlarmBitMap:      Clear
 
tinky.1.7.PXM.a >

dspcderrs

The dspcderrs command displays information about card errors.

Full Name

Display Card Errors

Syntax

dspcderrs

Cards on Which This Command Executes

PXM, FRSM, AUSM, VISM

Attributes

Log: No State: Any Privilege: Any

Example

wilco.1.7.PXM.a > dspcderrs

Description

If no errors have occurred, no messages appear on screen.

System Response
dspcderrs
08/05/95-18:53:05 tRootTask    3 Task failed          : scm                     
09/05/95-09:14:08 tRootTask    3 Task failed          : scm                     
value = 0 = 0x0

dspcdprtntype

The dspcdprtntype command displays the card partition type on the current module.

Full Name

Display Card Resource Type

Syntax

dspcdprtntype

Related Commands

cnfcdprtntype

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.7.PXM.a > dspcdprtntype
Description

Display the card resource partition type on the current PXM

System Response
spirit.1.7.PXM.a > dspcdprtntype
cardLcnPartitionType : controllerBased 
 

dspcdrscprtn

The dspcdrscprtn command displays allocated resource information to a controller. This command applies to cards with a card partition type of controllerBased.

Full Name

Display Card Resource Partition

Syntax

dspcdrscprtn

Related Commands

addcdrscprt

Cards on Which This Command Executes

PXM, FRSM, AUSM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1
spirit.1.13.VHS2CT3.a > dspcdrscprtn
 
Description

Display the number of LCNs available for each of the three possible partitions on the current card (FRSM 2CT3).

System Response
 
   User   Status  NumOfLcnAvail
  ------  ------  -------------
   PAR     Add       1000
   PNNI    Add       1000
   TAG     Add       1000
 
 
Example 2
 
spirit.1.17.CESM.a > dspcdrscprtn
Description

Display the number of LCNs available for each of the three possible partitions on the current card (CESM 8T1).

System Response
  
   User   Status  NumOfLcnAvail
  ------  ------  -------------
   PAR     Mod         248
   PNNI    Mod         248
   TAG     Mod         248
Example 3
spirit.1.1.FRSM.a > dspcdrscprtn
Description

Display the number of LCNs available for each of the three possible partitions on the current card (FRSM 8T1).

System Response
  
   User   Status  NumOfLcnAvail
  ------  ------  -------------
   PAR     Add       1000
   PNNI    Add       1000
   TAG     Add       1000
Example 4
 
spirit.1.7.PXM.a > dspcdrscprtn
Description

Display the number of LCNs available for each of the three possible partitions on the current card (PXM T1).

System Response
  
    Controller  Status    Number of Available LCNs
    -----------------------------------------------
    PAR         Enabled       32767
    PNNI        Enabled       32767
    TAG         Enabled       32767

dspcds

The dspcds command displays the status of all the cards in the MGX 8850 shelf.

Full Name

Display Card Shelf Information

Syntax

dspcds

Related Commands

dspcd

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
wilco.1.7.PXM.a > dspcds  
Description

Display all cards in the switch (executed from a PXM).

System Response

The following represents the first of three screens.

 
    Slot  CardState    CardType     CardAlarm  Redundancy
    ----  -----------  --------     ---------  -----------
    1.1   Active       FRSM-8T1     Major
    1.2   Empty                     Clear
    1.3   Active       FRSM-2CT3    Clear
    1.4   Empty                     Clear
    1.5   Empty                     Clear
    1.6   Empty                     Clear
    1.7   Active       PXM1-T3E3    Major
    1.8   Empty                     Clear
    1.9   Empty                     Clear
    1.10  Empty                     Clear
    1.11  Empty                     Clear
    1.12  Active       RPM          Clear
    1.13  Empty                     Clear
    1.14  Empty                     Clear
    1.15  Empty                     Clear
    1.16  Empty                     Clear
    1.17  Active       CESM-8E1     Clear
    1.18  Empty                     Clear
    1.19  Empty                     Clear
 
Type <CR> to continue, Q<CR> to stop:
 

After hitting return, the second screen displays:

 
    Slot  CardState    CardType     CardAlarm  Redundancy
    ----  -----------  --------     ---------  -----------
    1.20  Empty                     Clear
    1.21  Empty                     Clear
    1.22  Empty                     Clear
    1.25  Empty                     Clear
    1.26  Empty                     Clear
    1.27  Empty                     Clear
    1.28  Empty                     Clear
    1.29  Empty                     Clear
    1.30  Empty                     Clear
    1.31  Empty                     Clear
    1.32  Empty                     Clear
 
    NumOfValidEntries:    32
    NodeName:             wilco
    Date:                 02/01/1999
    Time:                 07:32:41
    TimeZone:             PST
    TimeZoneGMTOff:       -8
    StatsMasterIpAddress: 0.0.0.0
 
Type <CR> to continue, Q<CR> to stop:
 

Press return again, and the final screen displays:

 
 
    shelfIntegratedAlarm: Major
    BkplnSerialNum:       12345
    BkplnType:            2
    BkplnFabNumber:       73-0123-01
    BkplnHwRev:           80
 
wilco.1.7.PXM.a >

dspchan

Displays a channel on a PXM, FRSM, VISM, AUSM, or CESM.

Full Name

Display Channel

Syntax

dspchan <channel number>

where:

channel number

is the channel number. For FRSM, the channel number is the DLCI. For the AUSM, the channel number is the vpi.vci. The CESM does not require a channel number. For the PXM, the range is 16 through 4111.

Related Commands

dspchans, cnfchan

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1

spirit.1.17.FRSM.a > dspchan 69

Description

Display the channel characteristics of channel 69 on an FRSM.

System Response
  ChanNum:                  69
  ChanRowStatus:            Mod
  ChanPortNum:              1
  ChanDLCI:                 100
  EgressQSelect:            1
  IngressQDepth:            65535
  IngressQDEThresh:         32768
  IngressQECNThresh:        65535
  EgressQDepth:             65535
  EgressQDEThresh:          32768
  EgressQECNThresh:         6553
  DETaggingEnable:          Disabled
  CIR:                      24000
  Bc:                       5100
  Be:                       5100
  IBS:                      100
  ForeSightEnable:          Enabled
  QIR:                      260
  MIR:                      62
  PIR:                      500
  ChanLocalRemoteLpbkState: Enabled
  ChanTestType:             TestOff
  ChanTestState:            NotInProgress
  ChanRTDresult:            65535 ms
  ChanType:                 NIW
  ChanFECNmap:              setEFCIzero
  ChanDEtoCLPmap:           mapCLP
  ChanCLPtoDEmap:           mapDE
  ChanFrConnType:           PVC 
  ChanIngrPercentUtil:      100 
  ChanEgrPercentUtil:       100 
  ChanEgrSrvRate:           1536000 
  ChanOvrSubOvrRide:        Enabled 
  ChanLocalVpi:             0 
  ChanLocalVci:             100 
  ChanLocalNSAP:            535052494e543031000000000000000002000100 
  ChanRemoteVpi:            10 
  ChanRemoteVci:            134 
  ChanRemoteNSAP:           535052494e543031000000000000000000000100 
  ChanMastership:           Master 
  ChanVpcFlag:              Vcc 
  ChanConnServiceType:      ATFR 
  ChanRoutingPriority:      1 
  ChanMaxCost:              255 
  ChanRestrictTrunkType:    No Restriction 
  ChanConnPCR:              4000 
  ChanConnMCR:              4000 
  ChanConnPercentUti:       100 
 
  ChanNumNextAvailable:  17
Example 2
spirit.1.19.AUSM8.a > dspchan 16
Description

Display the channel characteristics of channel 16 on an AUSM.

System Response
 
  ChanNum:                           16
  RowStatus:                         Del
  ConnectionType:                    VCC
  ServiceType:                       CBR
  ChanSvcFlag:                       PVC
  PortNum:                           1
  VPI:                               0
  VCI (For VCC):                     0
  Local VPId(for VPC):               0
  EgressQNum:                        0
  IngressQDepth(cells):              1000
  IngressDiscardOption:              CLP hysterisis
  IngressFrameDiscardThreshold       1000
  IngressQCLPHigh(cells):            900
  IngressQCLPLow(cells):             800
  QCLPState:                         LOW
  IngressEfciThreshold(cells):       1000
  UPCEnable:                         Enabled
  PeakCellRate[0+1](cells/sec):      50
  CellDelayVariation[0+1]:           10000 (micro secs)
  PeakCellRate[0](cells/sec):        50
  CellDelayVariation[0]:             10000 (micro secs)
  SustainedCellRate(cells/sec):      50
  MaximumBurstSize(cells):           1000
  SCRPolicing:                       CLP[0]
  CLPTagEnable:                      Enabled
  FrameGCRAEnable:                   Disable
  ForesightEnable:                   Disable
  InitialBurstSize(cells):           0
  ForeSightPeakCellRate(cells/sec):  50
  MinimumCellRate(cells/sec):        0
  InitialCellRate(cells/sec):        1
  LocalRemoteLpbkState:              Disable
  ChanTestType:                      No Test
  ChanTestState:                     Not In Progress
  ChanRTDresult:                     65535 ms
  Ingress percentage util:           100
  Egress percentage util :           100
  Egress Service Rate:               50
  LocalVpi:                          0
  LocalVci:                          0
  LocalNSAP:                         5468697320697320612064756d6d79204e534150
  RemoteVpi:                         0
  RemoteVci:                         0
  RemoteNSAP:                        5468697320697320612064756d6d79204e534150
  Mastership:                        Slave
  VpcFlag:                           Vcc
  ConnServiceType:                   CBR
  RoutingPriority:                   1
  MaxCost:                           255
  RestrictTrunkType:                 No Restriction
  ConnPCR:                           50
  ConnMCR:                           0
  ConnPercentUtil:                   100
 
  ChanNumNextAvailable     :  17
  Local VpId NextAvailable :  2
Example 3
MGX-01.1.1.CESM.a > dspchan 32 
Description

Display the channel characteristics of channel 32 on the current CESM.

System Response
  ChanNum:                  32 
  ChanRowStatus:            Add 
  ChanLineNum:              1 
  ChanMapVpi:               1 
  ChanMapVci:               32 
  ChanCBRService:           structured 
  ChanClockMode:            Synchronous 
  ChanCAS:                  Basic 
  ChanPartialFill:          47 
  ChanMaxBufSize:           6144 bytes 
  ChanCDV:                  6000 micro seconds 
  C L I P:                  2500 milliseconds 
  ChanLocalRemoteLpbkState: Disabled 
  ChanTestType:             TestOff 
  ChanTestState:            NotInProgress 
  ChanRTDresult:            65535 ms 
  ChanPortNum               1 
  ChanConnType              PVC 
  ISDetType                 DetectionDisabled 
  CondData                  255 
  CondSignalling            0 
  ExtISTrig                 DisableIdleSupression 
  ISIntgnPeriod             4095 seconds 
  ISSignallingCode          0 
  OnHookCode                1 
  ChanLocalVpi:             0 
  ChanLocalVci:             1 
  ChanLocalNSAP:            535052494e543031000000000000000001000100 
  ChanRemoteVpi:            10 
  ChanRemoteVci:            132 
  ChanRemoteNSAP:           535052494e543031000000000000000000000100 
  ChanMastership:           Master 
  ChanVpcFlag:              Vcc 
  ChanConnServiceType:      CBR 
  ChanRoutingPriority:      1 
  ChanMaxCost:              255 
  ChanRestrictTrunkType:    No Restriction 
  ChanConnPCR:              4128 
  ChanConnMCR:              4128 
  ChanConnPercentUtil:      100 
 
  ChanNumNextAvailable:  32 
 
Example 4
MGX-01.1.7.PXM.a > dspchan 16 
Description

Display the channel characteristics of channel 16 on the current PXM.

System Response
bbChanCnfNum                : 16 
bbChanRowStatus             : 1 
bbChanConnType              : 2 
bbChanServiceType           : 1 
bbChanConnDesc              : 0x828d4e30 
bbChanSvcFlag               : 2 
bbChanSvcConnId             : 0 
bbChanIfNum                 : 1 
bbChanVpi                   : 10 
bbChanVci                   : 134 
bbChanUpcEnable             : 1 
bbChanUpcPCR                : 50 
bbChanUpcCDVT               : 10000 
bbChanUpcSCR                : 0 
bbChanUpcMBS                : 0 
bbChanGcra1Action           : 1 
bbChanGcra2Action           : 1 
bbChanEfciThreshold         : 98304 
bbChanDiscardOption         : 1 
bbChanFrmDiscardThreshold   : 0 
bbChanClpHiThreshold        : 0 
bbChanClpLoThreshold        : 0 
bbChanCongstUpdateCode      : 1 
bbChanMaxCellMemThreshold   : 131072 
bbChanIngrPercentUtil       : 100 
bbChanEgrPercentUtil        : 100 
bbChanEgrSrvRate            : 50 
bbChanOvrSubOvrRide         : 2 
bbChanLocalVpi              : 10 
bbChanLocalVci              : 134 
bbChanLocalNsapAddr         : 0x828d4a20 
bbChanRemoteVpi             : 0 
bbChanRemoteVci             : 100 
bbChanRemoteNsapAddr        : 0x828d49f0 
bbChanMaster                : 2 
bbChanRtePriority           : 1 
bbChanMaxCost               : 255 
bbChanRestrictTrkType       : 1 
bbChanTestType              : 3 
bbChanTestState             : 4 
bbChanTestResult            : 0 
bbChanTestTypeCPESide       : 2 
bbChanTestStateCPESide      : 4 
bbChanUpcSCRPolicing        : 3 
bbConnVpcFlag               : 2 
bbConnServiceType           : 1 
bbConnPCR                   : 50 
bbConnSCR                   : 0 
bbConnPercentUtil           : 100 
bbRemoteConnPCR             : 50 
bbRemoteConnSCR             : 0 
bbRemoteConnPercentUtil     : 100 
Example 5
 
spirit.1.5.VISM8.a > dspchan 37
Description

Display the channel characteristics of channel 37 on the current VISM.

System Response
 
  ChanNum:                  37
  ChanRowStatus:            Add
  ChanLocalRemoteLpbkState: Disabled
  ChanTestType:             TestOff
  ChanTestState:            NotInProgress
  ChanRTDresult:            65535 ms
  ChanPortNum:              1
  ChanPvcType:              VoIP
  ChanConnectionType:       PVC
  ChanLocalVpi:             0
  ChanLocalVci:             1
  ChanLocalNSAP:            4e4f44454e414d45000000000000000005000100
  ChanRemoteVpi:            58
  ChanRemoteVci:            59
  ChanRemoteNSAP:           4e4f44454e414d45000000000000000000000100
  ChanMastership:           Master
  ChanVpcFlag:              Vcc
  ChanConnServiceType:      CBR
  ChanRoutingPriority:      1
  ChanMaxCost:              255
  ChanRestrictTrunkType:    No Restriction
 
Type <CR> to continue, Q<CR> to stop:
 
  ChanConnPCR:              100000
  ChanConnPercentUtil:      100
 
  ChanNumNextAvailable:  34
 
Syntax : dspchan "chan_num"
         channel number -- values : 32 - 255
 
 
spirit.1.5.VISM8.a >

dspchancnt

Displays the contents of the statistical counters for a channel.

Full Name

Display Channel Counters

Syntax

dspchancnt <channel number>

where:

channel number

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For PXM, 16-4111

· For AUSM, 16-1015

· For CESM-8T1/E1, 32-279

· For CESM-T3/E3, one connection starting at 32

Related Commands

dspchstats

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: Any

Example 1

wilco.1.17.FRSM.a > dspchancnt 69

Description

Display the counters for channel 69 of the current FRSM

System Response
ChanNum:          69
ChanState:        okay
 
ChanUpTime:       10186
 
                                  Tx                            Rx
                             ---------------            ---------------
  AbitState:                 Sending A=1                Receiving A=1
  ATMState:                  Not sending any state      Not receiving any state
  Total Frames:              0                          0
  Total Bytes:               0                          0
  Frames DE:                 0                          0
  Bytes DE:                  0                          0
  Frames Discarded:          0                          0
  Bytes Discarded:           0                          0
  FramesDiscXceedQDepth:     0                          0
  BytesDiscXceedQDepth:      0                          0
  FramesDiscXceedDEThresh:   0                          0
  Frames FECN:               0                          0
  Frames BECN:               0                          0
  FramesTagged FECN:         0                          0
  FramesTagged BECN:         0                          0
  KbpsAIR:                   0                          0
  FramesTaggedDE:            0                          0
  BytesTaggedDE:             0                          0
  RcvFramesDiscShelfAlarm:                              0
  XmtFramesDiscPhyLayerFail: 0
  XmtFramesDiscCRCError:     0
  XmtFramesDiscReAssmFail:   0
  XmtFramesDiscSrcAbort:     0
  XmtFramesDuringLMIAlarm:   0
  XmtBytesDuringLMIAlarm:    0
  RcvFramesDiscUPC:                                     0
  XmtFramesInvalidCPIs:      0
  XmtFramesLengthViolations: 0
  XmtFramesOversizedSDUs:    0
  XmtFramesUnknownProtocols: 0
  RcvFramesUnknownProtocols:                            0
Example 2

wilco.1.19.AUSM.a > dspchancnt 16

Description

Display the counters for channel 16 of the current AUSM.

System Response
  ChanNum:                         16
  ChannelState:                    Active
  ChannelEgressRcvState:           Normal
  ChannelEgressXmitState:          Normal
  ChannelIngressRcvState:          Normal
  ChannelIngressXmtState:          Normal
  ChanInServiceSeconds:            1126725
  ChanIngressPeakQDepth(cells):    1
  ChanIngressReceiveCells:         41160574
  ChanIngressClpSetCells:          0
  ChanIngressEfciSetRcvCells:      0
  ChanIngressUpcClpSetCells:       0
  ChanIngressQfullDiscardCells:    1
  ChanIngressClpSetDiscardCells:   0
  ChanIngressTransmitCells:        41160574
  ChanShelfAlarmDiscardCells:      0
 
 
Syntax : dspchancnt "chan_num"
         channel number---value ranging from 16 to 1015
Example 3
MGX-01.1.1.CESM.a > dspchancnt 32 
Description

Display the counters for channel 32 of the current CESM-8E1.

System Response
ChanNum:                   32 
Chan State:                alarm 
Chan RCV ATM State:        Receiving AIS OAM 
Chan XMT ATM State:        Sending AIS OAM 
Cell Loss Status:          Cell Loss 
Reassembled Cells:         0 
Generated Cells:           1134344 
Header Errors:             0 
Seqence Mismatches :       0 
Lost Cells:                0 
Channel Uptime (secs.)     277 
Signalling Status          Offhook 
  
 
Syntax : dspchancnt "chan_num" 
         channel number -- values : 32 - 279 

dspchanmap

The dspchanmap command displays interworking field mapping for a specified channel.

Full Name

Display Channel Map

Syntax

dspchanmap

Related Commands

cnfchanmap

Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Any Privilege: Any


dspchans

This command displays all the current channels on the card.

Full Name

Display Channels

Syntax

dspchans

Related Commands

dspchan, addchan, delchan

Cards on Which This Command Executes

FRSM, AUSM, CESM, PXM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1

spirit.11.1.FRSM.a > dspchans

Description

Display the channels on the current FRSM

System Response
    DLCI       Chan  EQ  I/EQDepth  I/EQDEThre  I/EECNThre  Fst/DE  Type  Alarm
  ------------- ---- -- ----- ----- ----- ----- ----- ----- --- --- ----- -----
  11.1.1.100    69   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.101    70   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.102    71   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.103    72   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.104    73   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.105    74   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.106    75   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.107    76   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.108    77   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.109    78   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.110    79   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.111    80   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.112    81   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.113    82   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.114    83   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.1.115    84   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
  11.1.2.100    85   1  65535/65535 32768/32768 65535/6553  Ena/Dis NIW    No
 
Example 2

wilco.1.7.PXM.a > dspchans

Description

Display the channels on the current PXM

System Response
Chan Stat Intf locVpi locVci conTyp srvTyp PCR[0+1] Mst rmtVpi rmtVci State 
---------------------------------------------------------------------------- 
  16 Ena    1     10     134  VCC    CBR         50 Slv     0     100 normal 
  32 Ena    1     10     132  VCC    CBR         50 Slv     0       1  alarm 
 
Example 3
spirit.1.5.VISM8.a > dspchans
Description

Display the channels on the current VISM

System Response
    Channel     ChanNum   Status
  ------------  -------   ------
  5.0.1.37        37       Add
 
  Number of channels:    1
 
  ChanNumNextAvailable:  33
 
Syntax : dspchans
 
spirit.1.5.VISM8.a >

Note  For an AUSM, the display is the same as for the dspcon command.

dspchstats

Displays the current statistics of a channel.

Full Name

Display Channel Statistics

Syntax

dspchstats <line#>.<1st_DS0>.<DLCI>

where:

line#

line number is in the range 1-8

1st_DS0

1st_DS0 is in the range of 1-24 for T1, 1-32 for E1

DLCI

DLCI is the connection for which the statistics are to be displayed

Related Commands
dspchan, dspchans
Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Any Privilege: Any

Example

wilco.1.17.FRSM.a > dspchstats 1.4.1000

Description

Display the counters for line 1, 1st_DS0 of 4, and DLCI of 1000 for the current FRSM.

System Response
                          lineNum:           1
                          Physical Port Num: 4
                          Logical Port Num:  2
                          ChanDLCI:          1000
                          ChanNum:           1
                          ChanState:        okay
 
                          ChanUpTime:       10186
 
                                  Tx                            Rx
                             ---------------            ---------------
  AbitState:                 Sending A=1                Receiving A=1
  ATMState:                  Not sending any state      Not receiving any state
  Total Frames:              0                          0
  Total Bytes:               0                          0
  Frames DE:                 0                          0
  Bytes DE:                  0                          0
  Frames Discarded:          0                          0
  Bytes Discarded:           0                          0
  FramesDiscXceedQDepth:     0                          0
  BytesDiscXceedQDepth:      0                          0
  FramesDiscXceedDEThresh:   0                          0
  Frames FECN:               0                          0
  Frames BECN:               0                          0
  FramesTagged FECN:         0                          0
  FramesTagged BECN:         0                          0
  KbpsAIR:                   0                          0
  FramesTaggedDE:            0                          0
  BytesTaggedDE:             0                          0
  RcvFramesDiscShelfAlarm:                              0
  XmtFramesDiscPhyLayerFail: 0
  XmtFramesDiscCRCError:     0
  XmtFramesDiscReAssmFail:   0
  XmtFramesDiscSrcAbort:     0
  XmtFramesDuringLMIAlarm:   0
  XmtBytesDuringLMIAlarm:    0
  RcvFramesDiscUPC:                                     0
  XmtFramesInvalidCPIs:      0
  XmtFramesLengthViolations: 0
  XmtFramesOversizedSDUs:    0
  XmtFramesUnknownProtocols: 0
  RcvFramesUnknownProtocols:                            0

dspclkinfo

The dspclkinfo command displays detailed information about all the configured clock sources in the node.

Full Name

Display Clock Information

Syntax

dspclkinfo

Related Commands

dspclksrc, cnfclksrc

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 3

Example
spirit3.1.7.PXM.a > dspclkinfo
Description

Displays the detailed clock information for the MGX 8850 shelf.

System Response
 
 ****** Clock HW registers ********
SEL_T1 = t1      SEL100 = ON     SEL120 = ON     SEL120 = ON
NOEXTCLK = ON
 
 priMuxClockSource = INTERNAL_OSC
 prevPriMuxClockSource = INTERNAL_OSC
 primaryInbandClockSourceLineNum = 0
 secMuxClockSource = EXTERNAL_CLOCK
 prevSecMuxClockSource = EXTERNAL_CLOCK
 secondaryInbandClockSourceLineNumber = 1
 currentClockSetReq = primary
 currentClockHwStat = primary
 PreviousClockHwStat = internal
 extClockPresent = No
 extClkConnectorType = RJ45
 extClkSrcImpedance = 100 Ohms
 Internal Clock Status=1, Primary Clock Status=1
 
                 Secondary Clock Status=0, Last inband Clock State=0
 last Inband Clock state= 0, Last External Clock Present = 1

dspclksrc

The dspclksrc command displays all the configured clock sources in the node.

Full Name

Display Clock Sources

Syntax

dspclksrc

Related Commands

cnfclksrc

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example

spirit3.1.7.PXM.a > dspclksrc

Description

Displays the current clock source for the MGX 8850 shelf.

System Response
  PrimaryClockSource:   Internal Oscillator
  SecondaryClockSource: External T1/E1 from C.O.
  CurrentClockSource:   Internal Oscillator
  ClockSwitchState:     NoChange
  ExtClkPresent:        Not Present
  ExtClkSrcImpedance:   75 ohms
  ExtClkConnectorType:  BNC

dspcmparm

dspcmparm SUPER_GP ANY_STATE -

 
spirit4.1.8.PXM.a > dspcmparm
CONNECTION MANAGEMENT PARAMETERS
    1   Maximum Routing Bundle            250
    2   Reroute Timer                     42
    3   Reset Timer                       YES
    4   Max Down/Up Per Pass              50
    5   Down/Up Timer                     30000
    6   Max Route Errs per cycle          5
    7   Time between Rrt cycles           5
    8   Max. Rrt Err cycles               1
    9   Routing pause timer               0
    10  Max msgs sent per update          10
    11  # of reroute groups used          50
    12  Starting size of RR grps          0
    13  Increment between RR grps         0
    14  Cost Based routing                NO
    15  Use cache based route selection   NO
    16  Use end-to-end delay for routing  NO
    17  Max Via Connections               1024
 
spirit4.1.8.PXM.a >
 

dspcon

Displays configuration data for a connection.

Full Name

Display Connection

Syntax

dspcon <port number> <connection number>

where:

port number

is the port number. The range is 1 through 8.

connection number

is the connection number. For the FRSM, connection number is the DLCI. For an AUSM or PXM, connection number is the vpi.vci. The CESM does not require connection number.

Related Commands

addcon, delcon, dspcons

Cards on Which This Command Executes

AUSM, PXM, FRSM, CESM, VISM

Attributes

Log: No State: Active Privilege: Any

Example 1

spirit3.1.22.CESM.a > dspcon 16

Description

Display the connection parameters for channel 16 on a CESM.

System Response
  ChanNum:                                  16
  RowStatus:                                Add
  ConnectionType:                           VCC
  ServiceType:                              CBR
  PortNum:                                  1
  VPI:                                      10
  VCI:                                      100
  EgressQNum:                               1
  IngressQDepth (cells):                    100
  IngressQCLPHigh (cells):                  70
  IngressQCLPLow (cells):                   60
  IngressEfciThreshold (cells):             50
  CompliantCellDelayVariation (micro secs): 0
  CompliantInfoRate (cells/sec):            0
  InitialBurstSize (cells):                 0
  MaxFrameSize (cells):                     0
  PeakInformationRate (cells/sec)           1000
  CLPTagEnable:                             Disabled
  FrameGCRAEnable:                          Disabled
 
Example 2
spirit.1.3.FRSM.a > dspcon 3.500
Description

Display the connection parameters for the connection on channel 51 (port 3, DLCI 500) on the current FRSM.

System Response
  ChanNum:                  51
  ChanRowStatus:            Mod
  ChanPortNum:              3
  ChanDLCI:                 500
  EgressQSelect:            2
  IngressQDepth:            65535
  IngressQDEThresh:         32768
  IngressQECNThresh:        6554
  EgressQDepth:             65535
  EgressQDEThresh:          32768
  EgressQECNThresh:         6554
  DETaggingEnable:          Disabled
  CIR:                      1024000
  Bc:                       5100
  Be:                       5100
  IBS:                      100
  ForeSightEnable:          Enabled
  QIR:                      2666
  MIR:                      2666
  PIR:                      5333
  ChanLocalRemoteLpbkState: Disabled
  ChanTestType:             TestOff
  ChanTestState:            NotInProgress
  ChanRTDresult:            65535 ms
  ChanType:                 SIW-Xlat    
  ChanFECNmap:              setEFCIzero
  ChanDEtoCLPmap:           mapCLP    
  ChanCLPtoDEmap:           mapDE    
  ChanFrConnType:           PVC
  ChanIngrPercentUtil:      100
  ChanEgrPercentUtil:       100
  ChanEgrSrvRate:           1024000
  ChanOvrSubOvrRide:        Enabled
  ChanLocalVpi:             0
  ChanLocalVci:             500
  ChanLocalNSAP:            73776973735f7031000000000000910003000300
  ChanRemoteVpi:            3
  ChanRemoteVci:            14
  ChanRemoteNSAP:           73776973735f7031000000000000910000000100
  ChanMastership:           Master
  ChanVpcFlag:              Vcc
  ChanConnServiceType:      ATFR
  ChanRoutingPriority:      1
  ChanMaxCost:              255
  ChanRestrictTrunkType:    No Restriction
  ChanConnPCR:              5333
  ChanConnMCR:              2666
  ChanConnPercentUti:       100
 
  ChanNumNextAvailable:  63
 
Example 3
spirit.1.5.VISM8.a > dspcon 37
Description

Display the connection parameters for the connection on channel 37 on the current VISM.

System Response
 
  ChanNum:                  37
  ChanRowStatus:            Add
  ChanLocalRemoteLpbkState: Disabled
  ChanTestType:             TestOff
  ChanTestState:            NotInProgress
  ChanRTDresult:            65535 ms
  ChanPortNum:              1
  ChanPvcType:              VoIP
  ChanConnectionType:       PVC
  ChanLocalVpi:             0
  ChanLocalVci:             1
  ChanLocalNSAP:            4e4f44454e414d45000000000000000005000100
  ChanRemoteVpi:            58
  ChanRemoteVci:            59
  ChanRemoteNSAP:           4e4f44454e414d45000000000000000000000100
  ChanMastership:           Master
  ChanVpcFlag:              Vcc
  ChanConnServiceType:      CBR
  ChanRoutingPriority:      1
  ChanMaxCost:              255
  ChanRestrictTrunkType:    No Restriction
 
Type <CR> to continue, Q<CR> to stop:
 
  ChanConnPCR:              100000
  ChanConnPercentUtil:      100
 
  ChanNumNextAvailable:  36
 
Syntax : dspcon "chan_num"
         channel number -- values : 32 - 255
 
 
spirit.1.5.VISM8.a >
 
 

dspconcnt

Displays the counter data for the specified connection.

Full Name

Display Connection Counters

Syntax

dspconcnt <con_id> <connection number>

where:

con_id

A string in the format port.vpi.vci where:

· port is in the range 1 through n, where n is the highest numbered port on the card.

· vpi is the virtual path interface, in the range 1-4095

· vci is the virtual channel interface, in the range 1-65535

Related Commands

addcon, delcon, dspcon, dspcons

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
 
spirit4.1.8.PXM.a > dspconcnt 2.39.45
 
Description

Display the connection counters for the connection on port 2 with a VPI of 39 and a VCI of 45 on the current PXM.

System Response
Channel Number               :         17
Channel State                :      alarm
Channel Ingress State        :      alarm
Channel Egress State         :      other
CLP=0  Rcvd. Cells           :          0
CLP=1  Rcvd. Cells           :          0
GCRA1  Non Conforming Cells  :          0
GCRA2  Non Conforming Cells  :          0
EOF    Cells Rcvd.           :          0
CLP=0  Discard Cells         :          0
CLP=1  Discard Cells         :          0
Total  Xmtd. Cells           :       7253
CLP=0  Xmtd. Cells           :          0
CLP=1  Xmtd. Cells           :      10867
CLP=0  Discard Cells to Port :          0
CLP=1  Discard Cells to Port :          0
 
spirit4.1.8.PXM.a >

dspcons

Displays details of all connections on the current card.

Full Name

Display Connections

Syntax

dspcons

Related Commands

dspcon, addcon, delcon

Cards on Which This Command Executes

AUSM, PXM, FRSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1

spirit3.1.1.AUSM.a > dspcons

Description

Display parameters for the connections on the current AUSM.

System Response
Chan    Port.VPI.VCI    ConnType    Service Type    PCRlot1   Q-Depth     State
30        1.10.100       VCC            ABR          3622      2000       Active
33        1.10.200       VPC            CBR          3622      100        Alarm
 
Example 2
 
spirit.1.5.VISM8.a > dspcons
Description

Display parameters for the connections on the current VISM.

System Response
 
  ConnId            ChanNum Status
------------------- ------- ------
spirit.5.1.0       37      Add
 
  ChanNumNextAvailable:  35
 
Syntax : dspcons
 

dspcurclk

Displays the current clock source for the switch.

Full Name

Display Current Clock Source

Syntax

dspcurclk

Related Commands

dspclksrc, cnfclksrc, dspclkinfo

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
spirit4.1.8.PXM.a > dspcurclk
Description

Display the current clock source for the connections on the current PXM.

System Response
        Current Clock Source
      ----------------------
Source Node: spirit4
 
Clock Level: --
Clock Type : INTERNAL
 
 
spirit4.1.8.PXM.a >
 
 

dsperr

The dsperr command displays the contents of either all error log files or a specific error log file.

Syntax

dsperr [-en <error slot>]

where:

-en

Indicates that you are specifying a particular log file.

error slot

Number of the error log file (optional)

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example 1
spirit3.1.7.PXM.a > dsperr
Description

Display all error log files. The output appears one screen at a time. A prompt appears at the bottom of the screen requesting you to continue to the next screen or quit.

System Response
----------
Stack Trace:
    0x801e5714 vxTaskEntry              +  c: sysTaskSetup()
    0x80024d2c sysTaskSetup             + 58: rmm_main()
    0x800dff7c rmm_main                 +624: rmm_process_message()
    0x800df764 rmm_process_message      + 98: rmm_delete_seat()
    0x800e0f54 rmm_delete_seat          + ac: ipc_remove_seat()
    0x800d1140 ipc_remove_seat          + 50: ipc_renumber_as_slave()
    0x800d0a10 ipc_renumber_as_slave    +208: my_free()
    0x800d3430 my_free                  +  8: ssiFree()
    0x8001c378 ssiFree                  + 8c: ssiEvent()
    0x800274dc ssiEvent                 +11c: ssiEvent()
    0x800277bc ssiEvent                 +3fc: sysStackTrace()
----------
No Dump Trace before the event
----------
No Dump Trace after the event
Type <CR> to continue, Q<CR> to stop:               
----------
Stack Trace:
    0x801e5714 vxTaskEntry              +  c: sysTaskSetup()
    0x80024d2c sysTaskSetup             + 58: rmm_main()
    0x800dff7c rmm_main                 +624: rmm_process_message()
    0x800df764 rmm_process_message      + 98: rmm_delete_seat()
    0x800e0f54 rmm_delete_seat          + ac: ipc_remove_seat()
    0x800d1140 ipc_remove_seat          + 50: ipc_renumber_as_slave()
    0x800d0a10 ipc_renumber_as_slave    +208: my_free()
    0x800d3430 my_free                  +  8: ssiFree()
    0x8001c378 ssiFree                  + 8c: ssiEvent()
    0x800274dc ssiEvent                 +11c: ssiEvent()
    0x800277bc ssiEvent                 +3fc: sysStackTrace()
----------
No Dump Trace before the event
----------
No Dump Trace after the event
Type <CR> to continue, Q<CR> to stop:                   
 
Example 2
spirit3.1.7.PXM.a > dsperr -en 3
Description

Display the error log for the card in slot 3. In this example, the card is an FRSM-8T1.

System Response
Stack Trace:
    0x801e5714 vxTaskEntry              +  c: sysTaskSetup()
    0x80024d2c sysTaskSetup             + 58: rmm_main()
    0x800dff7c rmm_main                 +624: rmm_process_message()
    0x800df764 rmm_process_message      + 98: rmm_delete_seat()
    0x800e0f54 rmm_delete_seat          + ac: ipc_remove_seat()
    0x800d1140 ipc_remove_seat          + 50: ipc_renumber_as_slave()
    0x800d0a08 ipc_renumber_as_slave    +200: ipc_remove_ports_on_seat()
    0x800d02a8 ipc_remove_ports_on_seat + a0: ipc_remove_port()
    0x800d01dc ipc_remove_port          +190: ipc_subsys_init()
    0x800cecf0 ipc_subsys_init          +204: my_free()
    0x800d3430 my_free                  +  8: ssiFree()
    0x8001c378 ssiFree                  + 8c: ssiEvent()
    0x800274dc ssiEvent                 +11c: ssiEvent()
    0x800277bc ssiEvent                 +3fc: sysStackTrace()
----------
No Dump Trace before the event
----------
No Dump Trace after the event
UNKNOWN.1.7.PXM.a >                                      
 

dspfst

Displays the current ForeSight parameter settings for the current service module. See the description of the cnffst command for an explanation of the ForeSight parameter settings.

Full Name

Display ForeSight Parameters

Syntax

dspfst

Related Commands

cnffst

Cards on Which This Command Executes

FRSM

Attributes

Log: Yes State: Active Privilege: 1-4

Example
wilco.1.3.VHS2CT3.a > dspfst
Description

Displays the current ForeSight parameter settings for the current service module (an FRSM-2CT3).

System Response

A typical response is shown below:

 
  RateUp:        10 percent
  RateDown:      87 percent
  RateFastDown:  50 percent
  QIRTimeout:    10 seconds
  RTD:           5 seconds
 

dspfw

Displays the current revision levels of the firmware in the MGX 8850 switch.

Full Name

Display Firmware Revisions

Syntax

dspfw

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
wilco.1.7.PXM.a > dspfw
System Response

A typical response is shown below:

1.0.00cd2
1.0.00gb5
1.0.00ce1

dspif

The dspif command displays configuration and state information for a broadband interface.

Full Name

Display Broadband Interface

Syntax

dspif <if_num>

where:

if_num

is the interface number in the range 1-32.

Related Commands

cnfif

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.7.PXM.a > dspif 1

Description

Display configuration and state information for broadband interface number 1.

System Response

A typical response is:

 ifNum  Status  Line  ingrPctBw egrPctBw minVpi maxVpi
------------------------------------------------------
  1     Ena       1       10       10        0     19
 

dspifcnt

The dspifcnt command displays the interface counters for a broadband interface.

Full Name

Display Interface Counters

Syntax

dspifcnt <if_num>

where:

if_num

Interface Number---a number in the range 1-32.

Related Commands

cnfifcnt

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.7.PXM.a > dspifcnt 1

Description

Display counters and state information for broadband interface number 1.

System Response

A typical response is:

Interface Num                  :          1
Interface State                : Line Failure
Total Cells                    :          0
Received RM Cells              :          0
Received OAM Cells             :          0
Received CLP0 Cells            :          0
Received CLP1 Cells            :          0
Received CLP0,Discarded Cells  :          0
Received CLP1,Discarded Cells  :          0
Transmitted OAM Cells          :          0
Transmitted RM Cells           :          0
Transmitted CLP0 Cells         :          0
Transmitted CLP1 Cells         :          0
 
wilco.1.7.PXM.a >
 

dspifip

The dspifip command displays all the configured interface IP addresses on the current PXM. The possible interfaces are Ethernet, SLIP, and ATM.

Full Name

Display Interface IP Configuration

Syntax

dspifip

Related Commands

cnfifip, delifip

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.7.PXM.a > dspifip

Description

Display the IP LAN configuration.

System Response
 
   Interface     IPAddress             NetMask       BroadcastAddress
  ------------  -----------------  ----------------- -----------------
   Ethernet     172.29.37.40        255.255.255.000
   Slip         1.1.1.6             255.255.255.000
   ATM                              255.255.255.000

dspifrsc

The dspifrsc command displays all resource partition information for the specified interface.

Full Name

Display Interface Resource Partition

Syntax

dspifrsc <if_num>

where:

if_num

Interface Number---a number in the range 1-32

Related Commands

dspif

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
POP1.1.7.PXM.a > dspifrsc 1
Description

Display the resource partition information for all controller types on broadband interface 1.

System Response

 bbIfNum Ctrlr Status ingrPctBw egrPctBw minVpi maxVpi minVci maxVci maxChans
-----------------------------------------------------------------------------
    1    PAR     Mod      100      100       1   2000      0  65535    2000
    1    PNNI    Ena      100      100       1   2000      0  65535   32767
    1    TAG     Ena      100      100       1   2000      0  65535   32767
    1    SVC     Dis        0        0       0      0      0      0       0
 
POP1.1.7.PXM.a >

dspifs

The dspifs command displays the list of configured broadband interfaces.

Full Name

Display List of Broadband Interfaces

Syntax

dspifs

Related Commands

upif, cnfif

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

POP1.1.7.PXM.a > dspifs

Description

Display configuration and state information for all the broadband interfaces on the current PXM. In the response below, only broadband interface number 1 exists on the current PXM.

System Response

A typical response is:

 ifNum  Status  Line  ingrPctBw egrPctBw minVpi maxVpi
------------------------------------------------------
  1     Ena       1       10       10        0     19
 

dspilmi

The dspilmi command displays the interim local management interface (ILMI) configuration.

Full Name

Display ILMI

Syntax

dspilmi <port_num>

where:

port_num

The number of the port in the range 1-8.

Related Commands

cnfilmi, dspilmicnt

Cards on Which This Command Executes

PXM, AUSM

Attributes

Log: No State: Any Privilege: Any

Example 1

spirit3.1.20.AUSM.a > dspilmi 1

Description

Display the ILMI configuration for port 1 on the AUSM.

System Response
  Port Num:                      1
  Signalling:                    No signalling
  SignallingVPI:                 0
  SignallingVCI:                 0
  ILMITrap:                      Disabled
  ILMI-Min-Trap-Interval (secs): 1
  KeepAlivePolling:              Disabled
  ErrorThreshold:                3
  EventThreshold:                4
  PollingInterval (secs):        30
  MinimumEnquiryInterval (secs):  10
  EXT Operation:                 port 2
Example 2

spirit3.1.7.PXM.a > dspilmi 1

Description

Display the ILMI configuration for port 1 on the PXM.

System Response
 
    Sig.    Ilmi     Sig  Sig   Ilmi          T491       T492   T493   Addr
    Port State/Type  Vpi  Vci Trap/Int KA ErrTh/Pollint EvntTh EnqInt  Reg.
    ---- ---------  ---- ---- -------- --- ------------- ------ ------ ----
       1 Off/none     0   16  Off/01   Off     3/v6        4     10     Off
 

dspilmicnt

The dspilmicnt command displays the ILMI counters.

Full Name

Display ILMI Counters

Syntax

dspilmicnt <port_num>

where:

port_num

port_num is in the range 1-8

Related Commands

cnfilmi, dspilmi

Cards on Which This Command Executes

AUSM, PXM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.20.AUSM.a > dspilmicnt 1

Description

Display the ILMI counters for port 1 on the current AUSM card.

System Response
  Port Num:                 1
  SNMPPDUsReceived:         0
  Get RequestsReceived:     0
  GetNextRequestsReceived:  0
  SetRequestsReceived:      0
  TrapReceived:             0
  GetResponseReceived       0
  GetResponseTransmitted:   0
  GetRequestTransmitted:    0
  TrapsTransmitted:         0
  InvalidPDUReceived:       0
  Asn1ParseError:           0
  NoSuchNameError:          0
  TooBigError:              0

dspilmis

The dspilmis command displays all the interim local management interface (ILMI) configurations.

Full Name

Display All ILMI Configurations

Syntax

dspilmis

Related Commands

cnfilmi, dspilmi, dspilmicnt

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.7.PXM.a > dspilmis

Description

Display the ILMI configuration for all ports on the PXM.

System Response
 
    Sig.    Ilmi     Sig  Sig   Ilmi          T491       T492   T493   Addr
    Port State/Type  Vpi  Vci Trap/Int KA ErrTh/Pollint EvntTh EnqInt  Reg.
    ---- ---------  ---- ---- -------- --- ------------- ------ ------ ----
       1 Off/none     0   16  Off/01   Off     3/v6        4     10     Off
 
 

dspimagrp

The dspimagrp command displays delay and resilient links IMA (inverse multiplexing ATM) parameters on the current AUSM card.

Full Name

Display IMA Group

Syntax

dspimagrp <aimux_grp>

where:

aimux_grp

AIMUX group number for the group to be displayed (1-8)

Related Commands

cnfimagrp, dspimagrps, dspimagrpcnt

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
spirit.1.19.AUSM8.a > dspimagrp 1
Description

Display all the detailed status and configuration information for AIMUX group 1 on the current card.

System Response
   IMA Group number                 : 1
   Port type                        : NNI
   Lines configured                 : 1.2.3
   Enable                           : Enabled
   IMA Port state                   : Sig. Failure
   IMA Group Ne state               : Startup
   PortSpeed (cells/sec)            : 13470
   GroupTxAvailCellRate (cells/sec) : 0
   ImaGroupTxFrameLength(cells)     : 128
   LcpDelayTolerance (IMA frames)   : 1
   ReadPtrWrPtrDiff  (cells)        : 4
   Minimun number of links          : 2
   MaxTolerableDiffDelay (msec)     : 200
   Lines Present                    :
   ImaGroupRxImaId                  : 0x100
   ImaGroupTxImaId                  : 0x0
   Observed Diff delay (msec)       : 0
   Clock Mode                       : CTC
   GroupAlpha                       : 2
   GroupBeta                        : 2
   GroupGamma                       : 1
 
Type <CR> to continue, Q<CR> to stop:
 
 
   GroupConfiguration               : 1
   IMAGrp Failure status            : Ne StartUp
   Timing reference link            : 1
 
 
Syntax : dspimagrp (or dspaimgrp) "imagroup_number"
         IMA group number -- value ranging from 1 to 8
 

dspimagrpcnt

This command displays IMA (inverse multiplexing ATM) counters on the current AUSM card for all IMA groups.

Full Name

Display IMA Group Counters

Syntax

dspimagrpcnt <aimux_grp>

where:

aimux_grp

AIMUX group number for the group to be displayed (1-8)

Related Commands

dspimagrp, dspimagrpcnt, dspimagrps, dspimainfo, dspimalncnt

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
spirit.1.19.AUSM8.a > dspimagrpcnt 1
Description

Display all the detailed status and configuration information for the IMA (inverse multiplexing ATM) counters for AIMUX group 1 on the current card.

System Response
  IMA Group number:                           1
  Ne Number of failures                   :   0
 

dspimagrps

The dspimagrps command displays IMA (inverse multiplexing ATM) parameters for AUSM.

Full Name

Display IMA Groups

Syntax

dspimagrps

Related Commands

dspimagrp, cnfimagrp, dspimainfo, dspimagrpcnt

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
spirit.1.19.AUSM8.a > dspimagrps
Description

Display all the IMA (inverse multiplexing ATM) parameter information for all AIMUX groups on the current card.

System Response
 List of IMA groups:
 ===================
 
ImaGrp PortType Speed  Lines configured  Lines present  Tol Diff  Port State
                                                        Delay(ms)
------ -------- -----  ----------------  -------------  --------- ----------
 19.1   NNI     13470  1.2.3                             200      Sig. Failure
 
  NextPortNumAvailable:  8

dspimainfo

This command displays information about IMA (inverse multiplexing ATM) parameters on the current AUSM card.

Full Name

Display AIM (or Display IMA) Information

Syntax

dspimainfo

Related Commands

dspimagrp, cnfimagrp

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
spirit.1.19.AUSM8.a > dspimainfo
 
Description

Display all the IMA (inverse multiplexing ATM) parameter information for all AIMUX groups on the current card.

System Response
 
Link      NeTx            NeRx           TxId   RxID
          State           State
-----------------------------------------------------
   1      (null)         (null)            0      0
   2      (null)         (null)            0      0
   3      (null)         (null)            0      0
   4      (null)         (null)            0      0
   5      (null)         (null)            0      0
   6      (null)         (null)            0      0
   7      (null)         (null)            0      0
   8      (null)         (null)            0      0
 
spirit.1.19.AUSM8.a >

dspimalncnt

This command displays all the AIMUX line counters for the specified line in an IMA trunk.

Full Name

Display AIM (or Display IMA) Line Count

Syntax

dspaimlncnt <aimux_grp> <line_num>

where:

aimux_grp

AIMUX group number. Range is 1 to 8.

line_num

AIMUX line number. Range is 1 to 8.

Related Commands

clraimlncnt, clrimalncnt, dspaimlncnt

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

Example
spirit.1.19.AUSM8.a > dspimalncnt 1 1
Description

Display the line counters for line 1 of IMA group 1.

System Response
 
   IMA group number                : 1
   Line number                     : 1
   Acp Cells Received              : 0
   Acp Errored Cells Recvd         : 0
   Port changed from LDS           : 0
   # HEC errored cells             : 0
   # HEC errored seconds           : 0
   # Severely HEC errored seconds  : 0
 
Syntax : dspimalncnt (or dspaimlncnt) imagroup linenum
         IMA group number -- value ranging from 1 to 8
         line number -- value ranging from 1 to 8
  

dsplink

The dsplink command displays a link on a T3 line on a SRM-3T3 card.

Full Name

Display Link

Syntax

dsplink <T3 line number>

where:

T3 line number

SRM-3T3 T3 line number is in the format slot.line, where slot is either 15 or 31, and line is in the range 1-3)

Related Commands

dellink, addlink

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 1

System Response

T3Line StartT TRowStatus TargetSlot TargetSlotLine

1

1

Add

7

1

1

2

Add

7

2

1

3

Add

7

3

1

4

Add

7

4

dsplmistats

The dsplmistats command displays all the local management interface (LMI) configurations.

Full Name

Display All LMI Statistics

Syntax

dspilmis

Related Commands

cnfilmi, dspilmi, dspilmicnt, dspilmis

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > dsplmistats
Description

Display the LMI statistics for the PXM.

System Response
  
Enabled        :          1   Port Status    :          0
VPI.VCI        :        3.31
Polling enable :          1
T393           :         10   N394           :          5
T394           :         10   N395           :          5
WaitStatus     :          0   WaitStAck      :          0
Retry Timer    :          0   Retry Count    :          0
Poll Timer     :          0   Trans Num      :          0
Status     Rx  :          0   Status     Tx  :          0
UpdtStatus Rx  :          0   UpdtStatus Tx  :          0
Status Enq Rx  :          0   Status Enq Tx  :          0
Status Ack Rx  :          0   Status Ack Tx  :          0
NodeStatus Rx  :          0   NodeStatus Tx  :      18329
NodeStaAck Rx  :          0   NodeStaAck Tx  :          0
Bad PDU Rx     :          0   Bad PDU Len Rx :          0
Unknown PDU Rx :          0   Invalid I.E. Rx:          0
Invalid Trans  :          0
BPX IP Addr    :  172.1.1.215
 
 
spirit4.1.8.PXM.a >

dspln

The dspln command displays the characteristics of a physical line. When the current card is a PXM, you must specify the line type:

Full Name

Display Line

Syntax

On a FRSM, AUSM, CESM, VISM

dspln <line number>

where:

line number

is the line number in the range 1-n, where n is the highest port number on the line module.

On PXM:

dspln <-ds3 | -e3 | -sonet> <line number>

where:

-ds3

indicates a T3 line specification follows.

-e3

indicates an E3 line specification follows.

-sonet

indicates a SONET line specification follows.

line number

is the line number in the format slot.line, where slot is either 7, 15, or 31, and line is in the range 1-n, where n is the highest port number on the line module.

Related Commands

addln, cnfln, delln

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: No State: Active on PXM, any state on service modules Privilege: Any

Example 1

spirit3.1.20.AUSM.a > dspln 2

Description

Display line 2 on the current AUSM card.

System Response
 LineNum:                 2
 LineConnectorType:       BNC
 LineType:                dsx1E1CAS
 LineEnable:              Enabled
 LineCoding:              dsx1HDB3
 LineLength:              G.703 75 ohm
 LineXmtClockSource:      LocalTiming
 LineLoopbackCommand:     NoLoop
 LineSendCode:            NoCode
 LineUsedTimeslotsBitMap: 0xffffffff
 ConfigChangePortBitMap:  0x0
 
  LineNumOfValidEntries: 4
Example 2

spirit3.1.7.PXM.a > dspln -ds3 7.1

Description

Display T3 line 1 on the current PXM.

System Response for PXM With BNC-2T3
 
  LineNum:               1
  LineType:              dsx3CbitParity
  LineCoding:            dsx3B3ZS
  LineLength:            lessThan225
  LineOOFCriteria:       fBits3Of8
  LineAIScBitsCheck:     Check C-bits
  LineLoopbackCommand:   NoLoop
  LineRcvFEACValidation: 4 out of 5 FEAC codes
  LineEnable:            Disable           
 
Example 3

spirit3.1.7.PXM.a > dspln -sonet 7.1

Description

Display OC-3 line 1 on the current PXM.

System Response for PXM With OC-3
  sonetLineNum:                 1
  sonetLineType:                sonetSts3c
  sonetLineLoopback:            NoLoop
  sonetHCSmasking:              Enabled
  sonetPayloadScramble:         Enabled
  sonetFrameScramble:           Enabled
  sonetLineEnable:              Disable
  sonetMediumType:              sonet
  sonetMediumTimeElapsed:       0
  sonetMediumValidIntervals:    0
  sonetMediumLineCoding:        NRZ
  sonetMediumLineType:          LongSingleMode
  sonetMediumCircuitIdentifier: Sonet Line
 
spirit.1.8.PXM.a >
Example 4
spirit3.1.3.FRSM.a > dspln 3
Description

Display line 3 on the current FRSM card.

System Response
  LineNum:                   3
  LineConnectorType:         RJ-48
  LineType:                  dsx1E1CLEAR
  LineEnable:                Enabled
  LineCoding:                dsx1HDB3
  LineLength:                G.703 120 ohm
  LineXmtClockSource:        LocalTiming
  LineLoopbackCommand:       NoLoop
  LineSendCode:              NoCode
  LineUsedTimeslotsBitMap:   0xffffffff
  LineLoopbackCodeDetection: codeDetectDisabled
  LineBertEnable:            Disable
 
  LineNumOfValidEntries: 8
 
Syntax : dspln "line_num" 
         line number -- values ranging from 1-8 are accepted, for FRSM_8
 
 

dsplnrsc

The dsplnrsc command displays resource partition information for a line.

Full Name

Display Line Resource

Syntax

dsplnrsc <line_num>

where:

line_num

is the line number in the range 1-n, and n is the highest numbered line on the PXM line module.

Related Commands

addrscprtn, cnfrscprtn

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.7.PXM.a > dsplnrsc 1
Description

Display partition information for line 1 on the current PXM.

System Response
 ifNum  Status  Line  ingrPctBw egrPctBw minVpi maxVpi
------------------------------------------------------
    1      1      1       100      100       0   4095
 

dsplns

The dsplns command displays the configuration for all lines on the current card. The displayed parameters depend on the card. On the PXM, you must specify the line type.

Full Name

Display Lines

Syntax

On all cards other than a PXM, enter dsplns without arguments. On a PXM:

dsplns <LineTable> <slot>

where:

LineTable

represents the line type. Enter "ds3," "e3," or "sonet." If you do not know the line type, execute dspcd.

slot

is either 7, 15, or 31

Related Commands

addln, cnfln, delln, dspcds, dspln

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: PXM: Active. Others: Any Privilege: Any

Example 1

spirit3.1.3.FRSM.a > dsplns

Description

Display lines on the current FRSM card.

System Response
  Line  Conn      Type     Status/Coding      Length     XmtClock Alarm Stats
        Type                                             Source         Alarm
  ----  ----- ------------ ------ -------- ------------- -------- ----- -----
  3.1   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  3.2   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  3.3   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  3.4   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  3.5   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  3.6   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  3.7   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  3.8   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
Example 2

spirit3.1.7.PXM.a > dsplns ds3 7

Description

Display lines on the current PXM with BNM-T3E3 trunk card.

System Response
Line       Type        Coding      Length       Criteria   AIScBitsCheck
----  --------------  --------  -------------  ----------- -------------
1  dsx3CbitParity     Dis / dsx3B3ZS  lessThan225    fBits3Of8   Check C-bits
1  dsx3CbitParity     Dis / dsx3B3ZS  lessThan225    fBits3Of8   Check C-bitLineNumOfValidEntries: 1
Example 3

spirit3.1.19.AUSM.a > dsplns

Description

Display lines on the current AUSM.

System Response
Medium   Medium   Medium    Medium 
  Line  Conn      Type     Status/Coding      Length     XmtClock Alarm Stats
        Type                                             Source         Alarm
  ----  ----- ------------ ------ -------- ------------- -------- ----- -----
  19.1  SMB   dsx1E1CCS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  19.2  SMB   dsx1E1CCS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  19.3  SMB   dsx1E1CCS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  19.4  SMB   dsx1E1CCS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  19.5  SMB   dsx1E1CCS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  19.6  SMB   dsx1E1CCS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  19.7  SMB   dsx1E1CCS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  19.8  SMB   dsx1E1CCS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  LineNumOfValidEntries: 8
 
Example 4
spirit.1.8.PXM.a > dsplns sonet 7
Description

Display lines on the PXM with OC3.

System Response
                                                    Medium  Medium Medium Medium
  Sonet Line  Line   Line   HCS   Payload  Frame    Time    Valid  Line   Line
  Line  Type  Status Lpbk   mask  Scramble Scramble Elapsed Intvls Coding Type
  ----- ----- ------ ------ ---- -------- -------- ------- ------ ------ ------
   1   sonet Dis    NoLoop Ena  Enabled  Enabled   0       0      NRZ   LongSine
   2   sonet Dis    NoLoop Ena  Enabled  Enabled   0       0      NRZ   LongSine
   3   sonet Dis    NoLoop Ena  Enabled  Enabled   0       0      NRZ   LongSine
   4   sonet Dis    NoLoop Ena  Enabled  Enabled   0       0      NRZ   LongSine
Example 5
spirit3.1.7.PXM.a > dsplns sonet 7
Description

Display lines on the PXM with OC12.

System Response
                                                    Medium  Medium Medium Medium
  Sonet Line  Line   Line   HCS   Payload  Frame    Time    Valid  Line   Line
  Line  Type  Status Lpbk   mask  Scramble Scramble Elapsed Intvls Coding Type
  ----- ----- ------ ------ ---- -------- -------- ------- ------ ------ ------
   1   sonet Ena    NoLoop Ena  Enabled  Enabled   96734   96     Other LongSingleMode
 
spirit3.1.7.PXM.a >
 

dspload

The dspload command displays the connection load at a port. The purpose of this command is to help you determine whether adding more connections is advisable. The display shows the load in cells per second. The layout of the display is in rows and columns. One column exists for each port, and one row exists for each connection type. If the traffic is exceeding the bandwidth configured for the port, an "overload" message appears at the bottom of the column for the overloaded port.

Full Name

Display Loads

Syntax

dspload

Related Commands

none

Cards on Which This Command Executes

AUSM, PXM

Attributes

Log: No State: Active Privilege: Any

Example

spirit3.1.20.AUSM.a > dspload

Description

Display the load on the current AUSM.

System Response
                Load Display for AUSM ports
 
                        Port 1  Port2   Port3   Port4
                        *******************************
CBR (based on PCR0+1)       0       0       0       0
 
VBR (based on PCR0+1)       0       0       0       0
 
ABR (based on MCR)      64000   64000   64000   64000
                        -------------------------------
 
Total                   64000   64000   64000   64000
 
Load Status             OverloadOverloadOverloadOverload
 
Note: All Cell Rates are multiplied by respective
                Percentage Utilization factors

dsplog

The dsplog command displays the events and messages in the log. The most recent events appear at the top of the list.

The dsplog command displays the MGX 8850 log. If you enter the command without either of the optional parameters, the system displays the entire log for all cards. Optionally, you can display the log for a particular card or a particular log entry.

Full Name

Display Log

Syntax

dsplog [ -log log slot ] [ -sl slot# ]

where:

log slot

is the number in the event file.

slot#

is the slot number of the card whose log you want to display.

Related Commands

clrlog, dsplogs

Cards on Which This Command Executes

PXM, FRSM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.7.PXM.a > dsplog

Description

Display all the log files.

System Response
dsplog
04/01/70-13:10:03 tRootTask    2 Illegal msg received
04/01/70-13:10:07 aum        1312 local IP address not programmed
03/01/70-20:11:31 smm        1207 slave ack timeout   
 

dsplogs

The dsplogs command displays information from all event log files.

Full Name

Display Logs

Syntax

dsplogs

Related Commands

clrlog, dsplog

Cards on Which This Command Executes

PXM, FRSM

Attributes

Log: No State: Any Privilege: Any

Example
spirit11.1.7.PXM.a > dsplogs

Description

Display all the log files.

System Response
spirit11.1.7.PXM.a > dsplogs
log_file:   C:/LOG/event04.log
    created when 11/08/1998-19:19:58
    error sequence # :     0
 
log_file:   C:/LOG/event03.log
    created when 11/04/1998-03:34:38
    error sequence # :     0
 
log_file:   C:/LOG/event02.log
    created when 11/04/1998-03:18:26
    error sequence # :     0
 
log_file:   C:/LOG/event01.log
    created when 11/04/1998-03:15:22
    error sequence # :     0
 
 
 

dspmaptbl

The dspmaptbl command displays the numbers assigned to frame relay ports or ATM ports on the FRSM or AUSM, respectively.

Full Name

Display Map Table

Syntax

dspmaptbl

Related Commands

none

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: No State: Active Privilege: Any

Example 1

spirit3.1.17.FRSM.a > dspmaptbl

Description

Display the map table for the current FRSM.

System Response
PortNum  DLCI  ChanNum  LineNum
  -------  ----  -------  -------
   1       100    69        1
   1       101    70        1
   1       102    71        1
   1       103    72        1
   1       104    73        1
   1       105    74        1
   1       106    75        1
   1       107    76        1
   1       108    77        1
   1       109    78        1
   1       110    79        1
   1       111    80        1
   1       112    81        1
   1       113    82        1
   1       114    83        1
   1       115    84        1
   2       100    85        1
   2       101    86        1
   2       102    87        1
   2       103    88        1
 
Type <CR> to continue, Q<CR> to stop:
Example 2

spirit3.1.20.AUSM.a > dspmaptbl

Description

Display the map table for the current AUSM.

System Response
 PortNum  VPI  VCI ChanNum  Channel Type
  -------  ---  --- -------  ------------
   1       1    16   16        VCC
   1       1    17   17        VCC
   1       1    18   18        VCC
   1       1    19   19        VCC
   1       1    20   20        VCC
   1       1    21   21        VCC
   1       1    22   22        VCC
   1       1    23   23        VCC
   1       1    24   24        VCC
   1       1    25   25        VCC
   1       1    26   26        VCC
   1       1    27   27        VCC
   1       1    28   28        VCC
   1       1    29   29        VCC
   1       1    30   30        VCC
   1       1    31   31        VCC
   1       1    32   32        VCC
   1       1    33   33        VCC
   1       1    34   34        VCC
   1       1    35   35        VCC
 
Type <CR> to continue, Q<CR> to stop:
 

dspmnup

The dspmnup command displays the current values of mandatory update parameters.

Full Name

Display Mandatory Update Parameters

Syntax

dspmnup

Related Commands

cnfmnup

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
wilco.1.7.PXM.a > dspmnup
System Response
 
    1    Update Interval (sec)          : 15
    2    # nodes per Update Interval    : 20
 

dspmsgcnt

The dspmsgcnt command displays the control message counters for the card.

Full Name

Display Control Message Counters

Syntax

dspmsgcnt

Related Commands

clrmsgcnt

Cards on Which This Command Executes

FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1
spirit.1.19.AUSM8.a > dspmsgcnt
Description

Displays the control message counters for the current card (an AUSM).

System Response
  RiscXmtCtrlMsg:            88006
  RiscRcvCtrlMsg:            53494
  SARXmtCtrlMsg:             88006
  SARRcvCtrlMsg:             53494
  SARCtrlMsgDiscLenErr:      0
  SARCtrlMsgDiscCRCErr:      0
  SARCtrlMsgDiscUnknownChan: 0
  SARCtrlMsgLastUnknownChan: 0
Example 2
spirit.1.5.VISM8.a > dspmsgcnt
Description

Displays the control message counter for the current card (a VISM).

System Response
  RiscXmtCtrlMsg:            83606
  RiscRcvCtrlMsg:            83606
  SARXmtCtrlMsg:             83445
  SARRcvCtrlMsg:             83606
  SARCtrlMsgDiscLenErr:      0
  SARCtrlMsgDiscCRCErr:      0
  SARCtrlMsgDiscUnknownChan: 0
  SARCtrlMsgLastUnknownChan: 0
 
spirit.1.5.VISM8.a >

dspname

The dspname command displays the name of the node.

Full Name

Display Name

Syntax

dspname

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
wilco.1.7.PXM.a > dspname

System Response
Node Name : wilco
 

dspnw

The dspnw command displays the network that contains the current switch.

Full Name

Display Network

Syntax

dspnw

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > dspnw

System Response
 spirit4    1
-----------
 
spirit4.1.8.PXM.a >
 

dspnwip

The dspnwip command displays the network IP address for the switch.

Full Name

Display Network IP Address

Syntax

dspnwip

Related Commands

cnfnwip

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
wilco.1.7.PXM.a > dspnwip
 
Description

Display the network IP address for the switch.

System Response
Node IP : 192.0.0.0
 

dsponoff

The dsponoff command displays all the parameters activated by the onoff command for the current PXM.

Full Name

Display Onoff Command Settings

Syntax

dsponoff

Related Commands

onoff

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 2

Example
spirit4.1.8.PXM.a > dsponoff
Description

Display all the parameters activated by the onoff command for the current PXM.

System Response
 
    1   Background Updates        NO
    2   Dynamic BW Allocation     YES
    3   Cm Updates                YES
    4   Cm_Rerouting              YES
    5   Comm Fail Test            YES
    6   Deroute Delay             YES
    7   Auto Renum Fail Recov     YES
 
spirit4.1.8.PXM.a >

dspparifs

The dspparifs command displays all the PAR (Portable AutoRoute) interfaces for the current PXM.

Full Name

Display PAR (Portable AutoRoute) Interfaces

Syntax

dspparifs

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
spirit.1.7.PXM.a > dspparifs
Description

Display all the PAR (Portable AutoRoute) interfaces for the current PXM.

System Response
slot.port   type         status      vpi           vci          txRate     rxRae
--------------------------------------------------------------------------------
      7.1   UNI_IF       FAILED    0 to 4095     0 to 65535      96000      9600
     0.33   CLK_IF       FAILED    0 to    0     0 to     0          0         0
     7.33   UNI_IF           UP    0 to  255     0 to 65535     176604     17664
     7.34   UNI_IF           UP    0 to  255     0 to 65535     176604     17664
 
 

dspplpp

The dspplpp command displays all currently configured PLPP (Physical Layer Protocol Processor) parameters on the current AUSM card.

Full Name

Display PLPP

Syntax

dspplpp <port number>

where:

<port number>

port number is in the range 1-8 for an 8 port card

Related Commands

cnfplpp

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1

Example
 
spirit.1.19.AUSM8.a > dspplpp 1
Description

Display the PLPP (Physical Layer Protocol Processor) parameters for port 1 on the current AUSM card.

System Response
  PhysicalPortNumber:            1
  CellFraming:                   ATM
  CellScramble:                  Scramble
  Plpp Loopback:                 No Loopback
  Single-bit error correction:   Disabled

dspport

On an FRSM and CESM, the dspport command displays the port configuration for the specified port. On an AUSM, the dspport command displays the Physical Layer Protocol Processor configuration for the specified port.

Full Name

Display Port

Syntax

dspport <port number>

where:

On an FRSM, port number is the port number in the range 1-192 for T1, 1-248 for E1

or

On an AUSM or CESM, port number is the port number in the range 1-8

Related Commands

FRSM: addport, cnfport, delport

AUSM: upport, dnport

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Active Privilege: Any

Example 1

spirit3.1.17.FRSM.a > dspport 1

Description

Display the port configuration for port 1 on the current FRSM8-T1.

System Response
  SlotNum:                      7
  PortLineNum:                  1
  PortNum:                      1
  PortRowStatus:                Add
  PortDs0Speed:                 64k
  PortDs0ConfigBitMap:          0xffffff
  PortEqueueServiceRatio:       1
  PortFlagsBetweenFrames:       1
  PortSpeed:                    1536kbps
  SignallingProtocolType:       NoSignalling
  AsynchronousUpdates:          Disable
  T391LineIntegrityTimer:       10
  T392PollingVerificationTimer: 15
  N391FullStatusPollingCounter: 6
  N392ErrorThreshold:           3
  N393MonitoredEventCount:      4
  PortState:                    FailedDuetoLineFailure
  PortSignallingState:          No Signalling Failure
  CLLMEnableStatus:             Disable
  CLLMxmtStatusTimer:           0
  portType:                     frameRelay
  PortIngrPercentUtil:          200
  PortEgrPercentUtil:           150
  PortOversubscribed:           True
 PortSvcStatus:                Disable
 PortSvcInUse:                 Not In-Use
 PortSvcShareLcn:              Card-based
 PortSvcLcnLow:                0
 PortSvcLcnHigh:               0
 PortSvcDlciLow:               0
 PortSvcDlciHigh:              0
 
  PortDs0UsedLine1:             0x00ffffff
  PortDs0UsedLine2:             0x00ffffff
  PortDs0UsedLine3:             0x00ffffff
  PortDs0UsedLine4:             0x00ffffff
  PortNumNextAvailable:         60
Syntax : dspport "port_num"
         port number---values ranging from 1-192 are accepted
Example 2

spirit3.1.20.AUSM.a > dspport 1

Description

Display port 1 on the current AUSM.

  PortNumber:     1
  Cell Framing:   ATM
  Cell Scramble:  No Scramble
  Plpp Loopback:  No Loopback

dspportcnt

This command displays counters for a specified port.

Full Name

Display Port Counters

Syntax

dspportcnt <port number>

where:

port number

port number is in the range 1-192 for T1, 1-248 for E1 on the FRSM or CESM eight port cards, 1-8 on the AUSM, 1 on the CESM-T3/E3

Related Commands

cnfcd, dspcds

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: Any

Example 1

spirit3.1.20.AUSM.a > dspportcnt 1

Description

Display port counters on port 1 of the current AUSM.

System Response
 
  PortNum:                               1
  PortState:                             Sig. Failure
  IngressRcvCells:                       0
  IngressRcvCellRate (cells/sec):        0
  IngressRcvUtilization (percentage):    0
  IngressXmtCells:                       0
  IngressGFCErrorCells:                  0
  IngressVpiVciErrCells:                 0
  IngressUnknownVpiVci:                  0x0
  IngressRcvClpSetCells:                 0
  EgressRcvCells:                        0
  EgressRcvCellRate (cells/sec):         0
  EgressRcvUtilization (percentage):     0
  EgressXmtCells:                        0
  EgressXmtCellRate (cells/sec):         0
  EgressXmtUtilization (percentage):     0
  EgressPortAlarmDiscardCells:           0
  EgressXmtClpSetCells:                  0
  EgressXmtEfciSetCells:                 0
  PortXmtAisCells:                       0
  PortXmtSgmtLpbkCells:                  0
  PortRcvAisCells:                       0
  PortRcvFerfCells:                      0
  PortRcvSgmtLpbkCells:                  0
  PortRcvCrcErrOAMCells:                 0
  TotalIngressQFullDiscardCells:         0
  TotalIngressClpSetDiscardCells:        0
  TransmitFIFOFullCount (per card):      0
  ReceivedHECErrorCells:                 0
  HECErroredSeconds:                     0
  SeverelyHECErroredSeconds:             0
Example 2

spirit3.1.17.FRSM.a > dspportcnt 1

Description

Display port counters on port 1 of the current FRSM.

System Response
                                      Tx                 Rx
                               ---------------    ---------------
  Total Frames:                0                  0
  Total Bytes:                 0                  0
  Frames FECN:                 0                  0
  Frames BECN:                 0                  0
  Frames Abort:                0                  0
  Buf Not Available:           0                  0
  KbpsAIR:                     0                  0
  XmtFramesDiscXceedQDepth:    0
  XmtBytesDiscXceedQDepth:     0
  XmtFramesDuringLMIAlarm:     0
  XmtByteDuringLMIAlarm:       0
  XmtFramesUnderrun:           0
  RcvFramesDE:                                    0
  RcvFramesDiscCRCError:                          0
  RcvFramesDiscIllegalHeader:                     0
  RcvFramesDiscAlignmentError:                    0
  RcvFramesDiscIllegalLen:                        0
  RcvFramesDiscXceedDEThresh:                     0
  RcvFramesUnknownDLCI:                           0
  RcvLastUnknownDLCI:                             0
  RcvFramesTaggedFECN:                            0
  RcvFramesTaggedBECN:                            0
  RcvFramesTaggedDE:                              0
  Status:                      0                  0
  StatusInquiry:               0                  0
  AsynchUpdate:                0                  0
  RcvInvalidRequest:                              0
  RcvUNISeqMismatch:                              0
  RcvNNISeqMismatch:                              0
  UNISignallingTimeout:                           0
  NNISignallingTimeout:                           0
  FramesCLLM:                  0                  0
  BytesCLLM:                   0                  0
  CLLMFailures:                               		    0
 
 
Example 3
 spirit4.1.8.PXM.a > dspportcnt 1
 
Description

Display port counters on port 1 of the current PXM.

System Response
Interface Num                  :          1
Interface State                : Line Failure
Total Cells                    :          0
Received OAM Cells             :          0
Received RM Cells              :          0
Received CLP0 Cells            :          0
Received CLP1 Cells            :          0
Received CLP0,Discarded Cells  :          0
Received CLP1,Discarded Cells  :          0
Transmitted OAM Cells          :          0
Transmitted RM Cells           :          0
Transmitted CLP0 Cells         :     256656
Transmitted CLP1 Cells         :          0
 
spirit4.1.8.PXM.a >

dspportq

The dspportq command displays queue information for a specified port and egress queue on the AUSM.

Full Name

Display Port Queue Information

Syntax

dspportq <port number> <egress queue number>

where:

port number

port number is in the range 1-8

egress queue number

egress queue number is in the range 1-12

Related Commands

dspportqs

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.20.AUSM.a > dspportq 1 1

Description

Display queue information for egress queue 1 on port 1.

System Response
 
  ServicePortNum:                 1
  QueueNumber:                    1
  PortBinState:                   Disable
  ServiceSequence:                255
  QueueDepth(cells):              500
  CLPThresholdHigh(cells):        450
  CLPThresholdLow(cells):         400
  EFCIThreshold(cells):           400
  QueueAlgorithm:                 255
  MaxBandwidthIncrement:          4096
  MinBandwidthIncrement:          0
  QCLPState:                      Low
  QFullDiscardedCells:            0
  CLPSetDiscardedCells:           0
 
 
Syntax : dspportq "port_num egress_q"
         port number -- values ranging from 1-8
         queue # -- queue number : 1 - 16, 0 - for default in addchan

dspportqs

The dspportqs command displays queue information for all the egress queues on an AUSM port.

Full Name

Display Port Queue Information

Syntax

dspportqs

Related Commands

dspportq

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.19.AUSM8.a > dspportqs
Description

Display egress queue information for all the egress queues on the AUSM.

System Response
Port   Q Num  State   Q-Algo Service-Seq Depth-Max  CLP-High  CLP-Low  EFCI-Thrsh
----  -----  -----   ------ ----------- ---------  --------  -------  ----------
  1     1    Enabled    3       1           200      180        160      160
  1     2    Enabled    3       2           900      800        700      700
  1     3    Enabled    3       3           900      800        700      700
  4     1    Enabled    3       1           200      180        160      160
  4     2    Enabled    3       2           900      800        700      700
  4     3    Enabled    3       3           900      800        700      700
 
 
Syntax : dspportqs

dspportrscprtn

The dspportrscprtn command displays the port resource partition on the current PXM.

Full Name

Display Port Resource Partition Information

Syntax

dspportrscprtn

Related Commands

dspcdrscprtn, dsplnrsc, dsprscprtn

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
 
spirit4.1.8.PXM.a > dspportrscprtn
Description

Display the port resource partition on the current PXM.

System Response
 
    Port  Ctrlr  Row    PctBw       VPI          VCI       Max
    Num   Type   Stat   In/Out    min/max      min/max    GLCNs
    -------------------------------------------------------------
      1   PAR     ON   100/100      0/255        0/65535  32767
      1   PNNI    ON   100/100      0/255        0/65535  32767
      1   TAG     ON   100/100      0/255        0/65535  32767
      2   PAR     ON   100/100      0/255        0/65535  32767
      2   PNNI    ON   100/100      0/255        0/65535  32767
      2   TAG     ON   100/100      0/255        0/65535  32767
 
spirit4.1.8.PXM.a >

dspports

The dspports command displays information on all the ports on the current card.

Full Name

Display Ports

Syntax

dspports

Related Commands

addport, cnfport, delport, dspport

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: Any

Example 1

spirit3.1.17.FRSM.a > dspports

Description

Display the ports on the current FRSM.

System Response
   Port   Ena/Speed EQService  SignalType  T391 T392 N391 N392 N393 InAlarm
                       Ratio
  --------  --- ----- --------- ------------ ---- ---- ---- ---- ---- -------
  17.2.1    Add/1536k    1      NoSignalling   10   15    6    3    4   No
  17.2.2    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.3    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.4    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.5    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.6    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.7    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.8    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.9    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.10   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.11   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.12   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.13   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.14   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.15   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.16   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.17   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.18   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.19   Add/  64k    1      NoSignalling   10   15    6    3    4   No
Example 2
 
spirit.1.19.AUSM8.a > dspports
Description

Display the ports on the current AUSM.

System Response
 
No ATM T1/E1 UNI ports currently active
 
 List of IMA groups:
 ===================
 
ImaGrp PortType Speed  Lines configured  Lines present  Tol Diff  Port State
                                                        Delay(ms)
------ -------- -----  ----------------  -------------  --------- ----------
 19.1   NNI     13470  1.2.3                             200      Sig. Failure
 
  NextPortNumAvailable:  2
 
Syntax : dspports
 
 
spirit.1.19.AUSM8.a >
Example 3
 
MGX-01.1.1.CESM.a > dspports
Description

Display the ports on the current CESM.

System Response
  Port     Ena/Speed   Type 
  ------   --- ------ -------- 
  1.1.1    Add/1536k structur 
 
  Number of ports:    1 
 
  PortDs0UsedLine1:             0x00ffffff 
  PortDs0UsedLine2:             0x00000000 
  PortDs0UsedLine3:             0x00000000 
  PortDs0UsedLine4:             0x00000000 
  PortDs0UsedLine5:             0x00000000 
  PortDs0UsedLine6:             0x00000000 
  PortDs0UsedLine7:             0x00000000 
  PortDs0UsedLine8:             0x00000000 
  PortNumNextAvailable:         10 
 
Syntax : dspports 
  
 

dspportstats

The dspportstats command displays statistics information for a specified port on the FRSM.

Full Name

Display Port Statistics

Syntax

dspportstats <line#> <1st_DS0>

where:

line#

line number is in the range 1-8

1st_DS0

1st_DS0 is in the range 1-24, for T1, and 1-32 for E1

Related Commands

dspchstats

Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.17.FRSM.a > dspportstats 1 12

Description

Display statistics information for port 1 on first DS0 of 12.

System Response
Line Num:1
Physical Port Num: 12
Logical Port Num: 4
                                    Tx                 Rx
                               ---------------    ---------------
  Total Frames:                0                  0
  Total Bytes:                 0                  0
  Frames FECN:                 0                  0
  Frames BECN:                 0                  0
  Frames Abort:                0                  0
  Buf Not Available:           0                  0
  KbpsAIR:                     0                  0
  XmtFramesDiscXceedQDepth:    0
  XmtBytesDiscXceedQDepth:     0
  XmtFramesDuringLMIAlarm:     0
  XmtByteDuringLMIAlarm:       0
  XmtFramesUnderrun:           0
  RcvFramesDE:                                    0
  RcvFramesDiscCRCError:                          0
  RcvFramesDiscIllegalHeader:                     0
  RcvFramesDiscAlignmentError:                    0
  RcvFramesDiscIllegalLen:                        0
  RcvFramesDiscXceedDEThresh:                     0
  RcvFramesUnknownDLCI:                           0
  RcvLastUnknownDLCI:                             0
  RcvFramesTaggedFECN:                            0
  RcvFramesTaggedBECN:                            0
  RcvFramesTaggedDE:                              0
  Status:                      0                  0
  StatusInquiry:               0                  0
  AsynchUpdate:                0                  0
  RcvInvalidRequest:                              0
  RcvUNISeqMismatch:                              0
  RcvNNISeqMismatch:                              0
  UNISignallingTimeout:                           0
  NNISignallingTimeout:                           0
  FramesCLLM:                  0                  0
  BytesCLLM:                   0                  0
  CLLMFailures:                               		    0
 
 

dspred

The dspred command displays the current redundant slot links.

Full Name

Display Redundancy

Syntax

dspred

Related Commands

addred, delred

Cards on Which This Card Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
spirit.1.7.PXM.a > dspred
Description

Display the current redundant slot links on the switch.

System Response
  Primary  Primary  Primary  Secondary  Secondary  Secondary  Red.  Red.Slot
  SlotNum   Type     State    SlotNum     Type       State    Type   Cover
  -------  -------  -------  ---------  ---------  ---------  ----  --------
    3      FRSM-8T1  Active      4        FRSM-8T1   Standby   1:N     0
 
spirit.1.7.PXM.a >
 

dsprscprtn

The dsprscprtn command displays the resource partition information for the specified interface.

Full Name

Display Resource Partition

Syntax

dsprscprtn <if_num> <ctrlr_num>

where:

if_num

Interface Number---a number between 1 and 32

ctrlr_num

Controller Number---1:PAR 2:PNNI or 3:TAG

Related Commands

addrscprtn, cnfrscprtn

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
MGX-01.1.7.PXM.a > dsprscprtn 1 1 
 
Description

Display resource partition information for the PAR controller on broadband interface 1 on the current PXM.

System Response
 bbIfNum Ctrlr Status ingrPctBw egrPctBw minVpi maxVpi minVci maxVci maxChans 
----------------------------------------------------------------------------- 
    1      1    Ena       100      100       0   4095       0  65535   32767 
 

dsprscprtns

The dsprscprtns command displays the resource partition information for all the interfaces.

Full Name

Display Resource Partitions

Syntax

dsprscprtns

Related Commands

addrscprtn, cnfrscprtn

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
MGX-01.1.7.PXM.a > dsprscprtns
 
Description

Display resource partition information for all the broadband interfaces on the current PXM.

System Response
 bbIfNum Ctrlr Status ingrPctBw egrPctBw minVpi maxVpi minVci maxVci maxChans 
----------------------------------------------------------------------------- 
    1      1    Ena       100      100       0   4095       0  65535   32767 
 

dspsarcnt

The dspsarcnt command displays the Segmentation and Reassembly (SAR) counters for the current card.

Full Name

Display SAR counters

Syntax

dspsarcnt <ChanNum>

where ChanNum is:

Related Commands

dspsarcnts

Cards on Which This Command Executes

FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1

spirit3.1.13.CESM.a > dspsarcnt 22

Description

Display SAR count on the current CESM, channel 22.

System Response
                          SarShelfNum:         1
                          SarSlotNum:          13
                          SarChanNum:          22
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            11227853              11529804
  Total CellsCLP:         0                     0
  Total CellsAIS:         498805                0
  Total CellsFERF:        0                     302222
  Total CellsEnd2EndLpBk: 0                     0
  Total CellsSegmentLpBk: 0                     0
  RcvCellsDiscOAM:                              0
 
 
Syntax : dspsarcnt "chan_num"
         channel number---value ranging from 32 to 279
 
        possible errors are :
        a) illegal/invalid parameters
        b) channel doesn't exist
Example 2
wilco.1.1.FRSM.a > dspsarcnt 17
Description

Display SAR count on the current FRSM, channel 17.

System Response
 
                          SarShelfNum:         1
                          SarSlotNum:          1
                          SarChanNum:          17
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            0                     0
  Total CellsCLP:         0                     0
  Total CellsAIS:         3852                  0
  Total CellsFERF:        0                     0
  Total CellsEnd2EndLpBk: 0                     0
  Total CellsSegmentLpBk: 0                     0
  RcvCellsDiscOAM:                              0
 
 
Syntax : dspsarcnt "chan_num"
         channel number -- value ranging from 16 to 1015
 
        possible errors are :
        a) illegal/invalid parameters
        b) channel doesn't exist
 
 
Example 3

spirit3.1.4.AUSM.a > dspsarcnt 98

Description

Display SAR count for channel 98 on the current card (an AUSM).

System Response
                          SarShelfNum:         1
                          SarSlotNum:          4
                          SarChanNum:          98
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            141357                0
  Total CellsCLP:         0                     0
  Total CellsAIS:         0                     0
  Total CellsFERF:        0                     0
  Total CellsEnd2EndLpBk: 0                     0
  Total CellsSegmentLpBk: 0                     0
  RcvCellsDiscOAM:                              0
Example 4
 
spirit.1.5.VISM8.a > dspsarcnt 37
Description

Display SAR count for channel 37 on the current card (a VISM).

System Response
                          SarShelfNum:         1
                          SarSlotNum:          5
                          SarChanNum:          37
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            667605215             2717092629
  Total CellsCLP:         0                     0
  Total CellsAIS:         2151235452            2150307780
  Total CellsFERF:        229                   33554690
  Total CellsEnd2EndLpBk: 2150293128            15
  Total CellsSegmentLpBk: 50331906              2151235408
  RcvCellsDiscOAM:                              2
 
 
Syntax : dspsarcnt "chan_num"
         channel number -- values : 32 - 255
 
        possible errors are :
        a) illegal/invalid parameters
        b) channel doesn't exist

dspsarcnts

Displays the current SAR (segmentation and reassembly) counter values.

Full Name

Display SAR Counters

Syntax

dspsarcnts

Related Commands

dspsarcnt

Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Any Privilege: Any

Example
wilco.1.1.FRSM.a > dspsarcnts
System Response

A typical response is shown below:

 
                          SarShelfNum:         1
                          SarSlotNum:          1
                          SarChanNum:          0
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            0                     0
  Total CellsCLP:         0                     0
  Total CellsAIS:         0                     0
  Total CellsFERF:        0                     0
  Total CellsEnd2EndLpBk: 0                     0
  Total CellsSegmentLpBk: 0                     0
  RcvCellsDiscOAM:                              0
 
Type <CR> to continue, Q<CR> to stop:
 
                          SarShelfNum:         1
                          SarSlotNum:          1
                          SarChanNum:          2
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            3912                  9611
  Total CellsCLP:         0                     0
  Total CellsAIS:         0                     0
  Total CellsFERF:        0                     0
  Total CellsEnd2EndLpBk: 0                     0
  Total CellsSegmentLpBk: 0                     0
  RcvCellsDiscOAM:                              0
 
Type <CR> to continue, Q<CR> to stop:
 
                          SarShelfNum:         1
                          SarSlotNum:          1
                          SarChanNum:          3
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            0                     0
  Total CellsCLP:         0                     0
  Total CellsAIS:         0                     0
  Total CellsFERF:        0                     0
  Total CellsEnd2EndLpBk: 0                     0
  Total CellsSegmentLpBk: 0                     0
  RcvCellsDiscOAM:                              0
 
Type <CR> to continue, Q<CR> to stop:
 
                          SarShelfNum:         1
                          SarSlotNum:          1
                          SarChanNum:          15
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            0                     0
  Total CellsCLP:         0                     0
  Total CellsAIS:         0                     0
  Total CellsFERF:        0                     0
  Total CellsEnd2EndLpBk: 0                     0
  Total CellsSegmentLpBk: 0                     0
  RcvCellsDiscOAM:                              0
 
Type <CR> to continue, Q<CR> to stop:
 
                          SarShelfNum:         1
                          SarSlotNum:          1
                          SarChanNum:          17
                                Tx                      Rx
                          ---------------       ---------------
  Total Cells:            0                     0
  Total CellsCLP:         0                     0
  Total CellsAIS:         3952                  0
  Total CellsFERF:        0                     0
  Total CellsEnd2EndLpBk: 0                     0
  Total CellsSegmentLpBk: 0                     0
  RcvCellsDiscOAM:                              0
 

dspservrate

The dspservrate command displays the service rate in cells per second on the selected channel.

Full Name

Display Service Rate

Syntax

dspservrate <ChanNum>

where ChanNum is the channel number in the range:

Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Any Privilege: Any

Example

spirit3.1.17.FRSM.a > dspservrate 22

Description

Display the service rate on channel 22 on the current card.

System Response
Service Rate (cells/sec):      1000
 

dspshelfalm

The dspshelfalm command displays the shelf alarms for the MGX 8850 shelf. The status of every alarm appears in the display unless you include the optional argument and include a specific alarm number. See the example for the number for each alarm.

In the dspshelfalm display, the State column shows whether the alarm has been asserted. "Normal" means that no alarm has been asserted. If an alarm exists, State shows "Above Normal" or "Below Normal." The presence of the word "missing" in the State column means that the input is missing or ignored. The content of the Severity column indicates the severity of the alarm.

Full Name

Display Shelf Alarms

Syntax

dspshelfalm [-alm <alarm number>]

where the optional argument "-alm" indicates a specific alarm number, and alarm number is the specific alarm to display. The range for alarm number is 1-27.

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any


Example 1

spirit3.1.7.PXM.a > dspshelfalm

Description

Display the status of all the shelf alarms.

System Response
Alarm     Type     Unit Thresh Severity Measurable Val State
 ----- ------------ ---- ------ -------- ---------- --- -----
   1   Temperature    1  50      Minor      Yes    40  Normal
   2   Power Supply   1  0       Minor      No     0   missing
   3   Power Supply   2  0       Minor      No     0   missing
   4   DC Level       1  42-54   Minor      Yes    0   missing
   5   DC Level       2  42-54   Minor      Yes    47  Normal
   6   Fan Unit       1  2000    Minor      Yes    0   missing
   7   Fan Unit       2  2000    Minor      Yes    0   missing
   8   Fan Unit       3  2000    Minor      Yes    0   missing
   9   Fan Unit       4  2000    Minor      Yes    0   missing
   10  Fan Unit       5  2000    Minor      Yes    0   missing
   11  Fan Unit       6  2000    Minor      Yes    0   missing
 
  ASMNumOfValidEntries: 11
  ASMShelfAlarmState:   2
 
Example 2

spirit3.1.7.PXM.a > dspshelfalm -alm 6

Description

Display the status of shelf alarm 6.

System Response
 
spirit.1.7.PXM.a > dspshelfalm -alm 6
 Alarm     Type     Unit Thresh Severity Measurable Val State
 ----- ------------ ---- ------ -------- ---------- --- -----
   6   Power Supply   4  ?       Minor      No      0   Normal
  ASMNumOfValidEntries: 27
  ASMShelfAlarmState:   2 
spirit.1.7.PXM.a >

dspslftst

This command displays the self test routine on the current card.

Full Name

Display Self Test

Syntax

dspslftst

Related Commands

clrslftst, cnfslftst, runslftstno

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: Any user

Example
wilco.1.1.FRSM.a > dspslftst
Description

Display the self test results for the switch.

System Response
  SelfTestEnable:            Enabled
  SelfTestPeriod:            5
  SelfTestState:             SelfTest Passed
  SelfTestResultDescription: No failure information available
 
 

dspslftsttbl

Displays the current contents of the self test table.

Full Name

Display Self Test Table

Syntax

dspslftsttbl

Related Commands

dspslftst

Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Any Privilege: 1-6

Example
wilco.1.3.VHS2CT3.a > dspslftsttbl
System Response

A typical response is shown below:

Test #  Test Name                 Thold Fail Pass Last Enab Destr Card Rst
  1     CPU DRAM access test       1     0    0    P    Y    N     Y
  2     SAR self test              1     0    0    P    Y    N     Y
  3     ISE self test              1     0    0    P    Y    N     Y
  4     ESE self test              1     0    0    P    Y    N     Y
  5     CODE checksum test         1     0    0    P    Y    N     Y
  6     Line loopback test         1     0    0    P    Y    Y     Y
  7     FREEDM test                1     0    0    P    Y    Y     Y
  8     Data loopback test         1     0    0    P    Y    Y     Y
  9     CellBus test               1     0    0    P    Y    N     N
 
wilco.1.3.VHS2CT3.a >
 

dspslotlink

The dspslotlink command displays SRM-3T3 link information for all the lines on the specified service module slot.

Full Name

Display Slot Link

Syntax

dspslotlink <slot number>

where:

slot number

slot number for the displayed links.

Related Commands

delslotlink

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 1

Example
spirit3.1.7.PXM.a > dspslotlink 1
Description

Display the SRM-3T3 link information for slot 1.

System Response

A typical response is shown below:

Slot Num    : 1
Max Lines   : 0
Link Counter: 0
 
Slot  Line#  T3 Line#  T1 Slot#
====  =====  ========  =========
  1     1       0        0
  1     2       0        0
  1     3       0        0
  1     4       0        0
  1     5       0        0
  1     6       0        0
  1     7       0        0
  1     8       0        0

dspsmcnf

The dspsmcnf command displays configuration-enable status for the service modules in the system.
The output displays the following for each card slot:

Full Name

Display Service Module Configuration

Syntax

dspsmcnf

Related Commands

clrsmcnf

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: Any

Example
MGX 88003.1.3.PXM.a > dspsmcnf
Description

Display the configuration of all the service modules in the switch.

System Response
 
    slot      Card        Rate     Channel                         MIB     Feature
     No.      Type       Control    ized       IMA     MULTRKS   Version    Bits
   ------   ----------   -------   -------   -------   -------   -------   -------
      1     ------>  No configuration file exist for this slot  <------
      2     ------>  No configuration file exist for this slot  <------
      3     FRSM-8T1       On        On        Off       Off        20      0x3
 
      4     FRSM-8T1       On        On        Off       Off        20      0x3
 
      5     ------>  No configuration file exist for this slot  <------
      6     ------>  No configuration file exist for this slot  <------
 
 
      9     ------>  No configuration file exist for this slot  <------
     10     ------>  No configuration file exist for this slot  <------
     11     ------>  No configuration file exist for this slot  <------
     12     ------>  No configuration file exist for this slot  <------
     13     ------>  No configuration file exist for this slot  <------
     14     ------>  No configuration file exist for this slot  <------
 
 
     17     ------>  No configuration file exist for this slot  <------
     18     ------>  No configuration file exist for this slot  <------
     19     ------>  No configuration file exist for this slot  <------
     20     FRSM-8E1       Off       Off       Off       Off        20      0x0
 
     21     ------>  No configuration file exist for this slot  <------
     22     ------>  No configuration file exist for this slot  <------
 
 
     25     ------>  No configuration file exist for this slot  <------
     26     ------>  No configuration file exist for this slot  <------
     27     ------>  No configuration file exist for this slot  <------
     28     ------>  No configuration file exist for this slot  <------
     29     ------>  No configuration file exist for this slot  <------
     30     ------>  No configuration file exist for this slot  <------
 
 
spirit.1.7.PXM.a > 

dspsrmclksrc

The dspsrmclksrc command displays the SRM-3T3 clock source for a specified T3 line.

Full Name

Display SRM Clock Source

Syntax

dspsrmclksrc -ds3 <T3 line number>

where:

T3 line number

SRM-3T3 T3 line number is in the format slot.line, where slot is either 7, 15, or 31, and line is in the range 1-3

Related Commands

cnfsrmclksrc

Cards on Which This Command Executes

SRM-3T3

Attributes

Log: No State: Active Privilege: 1

Example

spirit.1.7.PXM.a > dspsrmclksrc -ds3 15.1
Description

Display the clock source for T3 line 1 on the SRM-3T3 in slot 15.

System Response
  LineNum:               1
  LineXmtClockSource:    backplane clock from BNM
 
spirit.1.7.PXM.a >

dspstatparms

The dspstatparms command displays the statistics parameters.

Full Name

Display Statistics Parameters

Syntax

dspstatparms

Cards on Which This Command Executes

PXM, AUSM, CESM, FRSM

Attributes

Log: No State: Active Privilege: 1

Example
wilco.1.3.VHS2CT3.a > dspstatparms
Description

Display statistics parameter settings on the current card (FRSM-2CT3).

System Response
TFTP Retry Count:               1
TFTP ACK time-out (sec):       60
Bucket Interval:                0
File Interval:                  0
Peak Enable Flag:        Disabled
Object Count:                   0         STATS COLLECTION: Disabled
Object Subtype Counts:    0  0  0  0
Total File Memory Used:         0
Number of File Allocated:       0
Current File Size:              0
Stat Memory Allocated:          0
Auto Memory Allocated:          0
Auto Mem Rgn Size:         6291456
 
wilco.1.3.VHS2CT3.a >

dspswfunc

The dspswfunc command displays the status of certain node-level, paid features on the node. The features are the feeder implementation (or default routing implementation) of the switch and virtual source/virtual destination (VSVD) control for ABR traffic.

Full Name

Display Software Function

Syntax

dspswfunc

Related Commands

cnfswfunc

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example
spirit.1.8.PXM.a > dspswfunc
 
Description

Display whether or not paid features (feeder implementation (or default routing implementation) of the switch and virtual source/virtual destination (VSVD) control for ABR traffic) have been enabled.

System Response
 
     1.   ABR VSVD(enable(yes)/disable(no):    NO
     2.   Node Type(routing(routing)/Feeder(fdr):   ROUTING
 

dspsysparm

The dspsysparm command displays system parameters.

Full Name

Display System Parameters

Syntax

dspsysparm

Related Commands

cnfsysparm

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.8.PXM.a > dspsysparm
Description

Display the system parameters for the node.

System Response
    Max Time Stamped Packet Age(msec)                                32
    Fail Connections On Communication Break                           YES
    Interval Statistics polling rate for VCs                          5
    Max Network Delay for 'v' connections(msec)                       112
    Max Network Delay for 'c' connections(msec)                       112
    Max Network Delay for 't' & 'p' connections(msec)                 112
    Max Network Delay for 'a' connections(msec)                       216
    Max Network Delay for High Speed Data connections(msec)           256
    Max Network Delay for CDP-CDP 'v' connections(msec)               512
    Max Network Delay for CDP-CDP 'c' connections(msec)               512
    Max Network Delay for CDP-CDP 't' & 'p' connections(msec)         512
    Max Network Delay for CDP-CDP 'a' connections(msec)               512
    Max Network Delay for CDP-CDP High Speed Data connections(msec)   512
    Max Local Delay for Interdom CDP-CDP 'v' conns (msec)             216
    Max Local Delay for Interdom CDP-CDP 'c' conns (msec)             216
    Max Local Delay for Interdom CDP-CDP 't' & 'p' conns(msec)        216
    Max Local Delay for Interdom CDP-CDP 'a' conns(msec)              216
    Max Local Delay for Interdom CDP-CDP High Speed Data conns(msec)  216
    Max Local Delay for Interdom High Speed Data conns (msec)         216
    FastPAD Jitter Buffer Size  (msec)                                3
    Enable Discard Eligibility                                        0
    Use Frame Relay Standard Parameters Bc and Be                     0
    Enable Connection Deroute Delay feature                           0
    Number of Consecutive Invalid Login Attempts to Cause Major Alarm 0
spirit.1.8.PXM.a >

dsptotals

Displays the line, port, and channel totals for the current card.

Full Name

Display Totals

Syntax

dsptotals

Related Commands

none

Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Any Privilege: 1-6

Example
spirit.1.13.VHS2CT3.a > dsptotals
System Response

A typical response is shown below:

 
       total active lines = 0/56
       total active ports = 0/256
       total active chans = 0/1000
 
spirit.1.13.VHS2CT3.a >
 

dsptrapip

The dsptrapip command displays the IP address that will be placed in outgoing traps.

Full Name

Display Outgoing Trap IP Address

Syntax

dsptrapip

Related Commands

addtrapmgr, deltrapmgr, xdsptrapmgr

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
spirit.1.8.PXM.a > dsptrapip
Description

Display the IP address that will be placed in outgoing traps.

System Response
 
Trap IP Address :172.29.22.214
 

dsptrapmgr

The dsptrapmgr command displays a list of all the SNMP Managers that are registered to receive traps.

Full Name

Display Trap Managers

Syntax

dsptrapmgr

Related Commands

cnftrapmgr

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
wilco.1.7.PXM.a > dsptrapmgr
Description

Display the configuration of all the SNMP Managers that are registered to receive traps on the switch.

System Response

     ipAddress     PortNum  RowStatus   ReadTrapFlag  NextTrapSeqNum
  ---------------  -------  ----------  ------------  --------------
  172.29.23.5       2500       Add           Off       14647
  172.29.27.111     2500       Add           Off       0
  172.29.37.75      2500       Add           Off       8624
  172.29.37.122        2       Add           Off       0
  172.29.37.171     2500       Add           Off       15244
  172.29.37.199     2500       Add           Off       7364
 
  LastTrapSeqNum:  0
  NumOfValidEntries:  6
 

dsptrkcnf

The dsptrkcnf command displays the configuration for a trunk.

Full Name

Display Trunk Configuration

Syntax

dsptrkcnf <slot.port>

where slot.port identifies the trunk.The variable slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.

Related Commands

addtrk, dsptrks, cnftrk, dsptrkload

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit3.1.8.PXM.a > dsptrkcnf 7.1
Description

Display the configuration on trunk 1 on the card in slot 7.

System Response
      TRUNK   CONFIGURATION
     -----------------------
     Statistical Reserve     : 1000
     CC Restriction          : NO
     Line Type               :
     Pass Sync               : TRUE
     Deroute Delay           : 0
     Traffic Classes         : FST FR NTS TS VOICE CBR VBR ABR
     Routing Cost            : 10
     Vcc Conids              : 0
     Vpc Conids              : 0

dsptrkload

The dsptrkload command displays load information for a trunk. This command applies to only the routing node implementation.

Full Name

Display Trunk Load

Syntax

dsptrkload <slot.port>

where slot.port identifies the trunk.The variable slot is either 7, 15, or 31 and port is a value in the range 1-n, and n is the highest numbered port on the card.

Related Commands

addtrk, dsptrks, cnftrk, dsptrkcnf

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit3.1.8.PXM.a > dsptrkload 7.1
Description

Display the load on trunk 1 on the card in slot 7.

System Response
 

dsptrks

The PAR command dsptrks displays all the trunks on the node. This command applies to only the routing node implementation.

Full Name

Display Trunks

Syntax

dsptrks

Related Commands

addtrk, cnftrk, dsptrkcnf, dsptrkload

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit3.1.8.PXM.a > dsptrks 
Description

Display all the trunks on the node.

System Response

   TRK    Current Alarm Status        Other End
 
   7.1    MAJOR Interface Failed      far3bpx1

dspunit391

The dspunit391 command displays the current setting for T391.

Full Name

Display UNI T391

Syntax

dspunit391

Related Commands

addtrk, cnftrk, dsptrkcnf, dsptrkload

Cards on Which This Command Executes

FRSM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.1.FRSM.a > dspunit391
 
Description

Display the current setting for T391.

System Response

System UNI T391 = 5 seconds
 
spirit.1.1.FRSM.a >

dspupgrade

This command displays the upgrade state for the two PXMs.

Full Name

Display Upgrade State

Syntax
dspupgrade
Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > dspupgrade
Description

Display the upgrade state for the two PXMs.

System Response
active: 'upgrade idle'
standby: 'upgrade idle'
 
spirit4.1.8.PXM.a >

dspusers

Displays the users that have been added to the configuration. The screen shows the user name and highest privilege level and displays the number of those levels above user-privilege.

Full Name

Display Users

Syntax

dspusers

Related Commands

adduser, deluser

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
wilco.1.7.PXM.a > dspusers
Description

Display the users configured for this shelf. The users in this example are Raoul and Duke.

System Response
 
    UserId        AccessLevel
    -------------------------
    cisco         CISCO_GP
    service       SERVICE_GP
    superuser     SUPER_GP
      raoul       GROUP3
       duke       GROUP1

dspver

This command displays the version of firmware running in both PXM cards.

Full Name

Display Firmware Version

Syntax
dspver
Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > dspver
Description

Display the version of firmware running in both PXM cards.

System Response
active: 1.0.00
standby: 1.0.00
 
spirit4.1.8.PXM.a >
 

dspvismip

The dspvismip command displays the IP configuration information for the VISM card. It displays the parameters that are configurable through cnfvismip.

Full Name

Display VISM IP Parameters

Syntax

dspvismip

Related Commands

cnfvismip

Cards on Which This Command Executes

VISM

Attributes

Log: No State: Active Privilege: Any

Example
spirit.1.5.VISM8.a > dspvismip
Description

Display the IP configuration information for the current VISM card

System Response
 
  VismIpAddress:       198.45.26.101
  NetMask:             255.255.255.0
 
spirit.1.5.VISM8.a >
 

exit

The exit command lets you exit the current CLI shell.

Full Name

Exit from CLI

Syntax

exit

Related Commands

bye, logout

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: Yes State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > exit
Description

Exit from the current CLI shell.

System Response
(session ended)

Help

Lists the commands available on the current card. The Help command is case-sensitive. This command takes no arguments, so it does not display information on individual commands.

Full Name

Help

Syntax

Help

Related Commands

none

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1
spirit1.1.8.PXM.a > Help
Description

Display the commands available on the current card. In this case, the card is a PXM.

System Response
 
    Available commands
    ------------------
    ?
    abort
    addchan
    addcon
    addlink
    addlmiloop
    addln
    addlnloop
    addport
    addred
    addtrapmgr
    addtrk
    adduser
    arpFlush
    arpShow
    bye
    cc
    clidbxlevel
    clrallcnf
    clralm
    clralmcnt
    clratmlncnt
    clratmlncnts
    clrchancnt
    clrchancnts
    clrconcnt
    clrconcnts
    clrerr
    clrifcnt
    clrifcnts
    clrlmistats
    clrlog
    clrportcnt
    clrportcnts
    clrscrn
    clrsmcnf
    clrsrmcnf
    cmdhistory
    cnfatmln
    cnfcdrscprtn
    cnfchan
    cnfchanq
    cnfclksrc
    cnfcmparm
    cnfcon
    cnfdate
    cnfextclk
    cnfif
 
Type <CR> to continue, Q<CR> to stop:
 
    Available commands
    ------------------
    cnfifastrk
    cnfifip
    cnfln
    cnfname
    cnfpasswd
    cnfport
    cnfportrscprtn
    cnfpref
    cnfsrmclksrc
    cnfstatsmgr
    cnfsysparm
    cnftime
    cnftmzn
    cnftmzngmt
    cnftrapip
    cnftrk
    cnfupcabr
    cnfupccbr
    cnfupcubr
    cnfupcvbr
    commit
    delchan
    delcon
    delifip
    dellink
    dellmiloop
    delln
    dellnloop
    delport
    delred
    delslotlink
    deltrapmgr
    deltrk
    deluser
    dncon
    dnif
    downloadflash
    drtop
    dspalm
    dspalmcnf
    dspalmcnt
    dspalms
    dspatmlncnf
    dspatmlncnt
    dspcd
    dspcderrs
    dspcdprtntype
    dspcdrscprtn
    dspcds
    dspchan
    dspchancnt
    dspchans
    dspclkinfo
    dspclksrc
    dspcmparm
    dspcon
    dspconcnt
    dspcons
    dspcurclk
    dsperr
 
Type <CR> to continue, Q<CR> to stop:
 
    Available commands
    ------------------
    dspfw
    dspif
    dspifcnt
    dspifip
    dspifrsc
    dspifs
    dsplink
    dsplmiloop
    dsplmistats
    dspln
    dsplnrsc
    dsplns
    dspload
    dsplog
    dsplogs
    dspname
    dspnw
    dspnwip
    dsponoff
    dspparifs
    dspportcnt
    dspportrscprtn
    dspports
    dspred
    dsprscprtn
    dsprscprtns
    dspshelfalm
    dspslotlink
    dspsmcnf
    dspsrmclksrc
    dspstatparms
    dspsysparm
    dsptrapip
    dsptrapmgr
    dsptrkcnf
    dsptrkload
    dsptrks
    dspupgrade
    dspusers
    dspver
    dumptrace
    exit
    formatdisk
    Help
    history
    ifShow
    install
    logout
    memShow
    mkfs
    myid
    newrev
    onoff
    pagemode
    passwd
    ping
    printlog
    printrev
    resetcd
    resetsys
 
Type <CR> to continue, Q<CR> to stop:
 
    Available commands
    ------------------
    restoreallcnf
    rnmnd
    routeShow
    routestatShow
    rrtcon
    rstupgrade
    saveallcnf
    sesntimeout
    showsyserr
    shutdisk
    smclrscrn
    softswitch
    switchcc
    syncdisk
    syserr
    timeout
    tstcon
    tstconseg
    tstdelay
    uncnfifastrk
    upcon
    upif
    users
    version
    who
    whoami
    xcnfifip
    xcnfred
    xcnfsrmlink
    xcnftrapmgr
    xdspred
    xdspsrmlink
    xdsptrapmgr
 
spirit1.1.8.PXM.a >
Example 2
spirit1.1.22.AUSM8.a > Help
Description

Display the commands available on the current card. In this case, the card is an AUSM.

System Response
  
Command               Logging  State   Priority
--------------------  -------  ------  -------------------------
?                     No       Any     Any User
Help                  No       Any     Any User
addaimgrp             Yes      Active  Group 1
addchan               Yes      Active  Group 2
addchanloop           No       Active  Group 4
addcon                Yes      Active  Group 2
addimagrp             Yes      Active  Group 1
addln                 Yes      Active  Group 1
addlns2aimgrp         Yes      Active  Group 1
addlns2imagrp         Yes      Active  Group 1
addport               Yes      Active  Group 1
addrscprtn            Yes      Active  Group 1
aimhelp               No       Any     Any User
clear                 No       Any     Any User
clraimgrpcnt          No       Active  Group 1
clraimlncnt           No       Active  Group 1
clralm                No       Any     Group 5
clralmcnt             No       Any     Group 5
clralmcnts            No       Any     Group 5
clralms               No       Any     Group 5
clrcderrs             No       Any     Super Group (0)
clrchancnt            No       Any     Group 5
clrchancnts           No       Any     Group 3
clrimagrpcnt          No       Active  Group 1
clrimalncnt           No       Active  Group 1
clrimatst             No       Any     Group 1
clrmsgcnt             No       Any     Group 5
clrportcnt            No       Any     Group 5
clrportcnts           No       Any     Group 5
clrsarcnt             No       Any     Group 5
clrsarcnts            No       Any     Group 5
clrscrn               No       Any     Any User
clrslftst             No       Any     Any User
cls                   No       Any     Any User
cnfaimgrp             Yes      Active  Group 1
cnfcdprtntype         Yes      Active  Group 2
cnfcdrscprtn          Yes      Active  Group 1
cnfchan               Yes      Active  Group 2
cnfchanfst            Yes      Active  Group 2
cnfchanq              Yes      Active  Group 2
cnfcon                Yes      Active  Group 2
cnffst                Yes      Active  Super Group (0)
cnfilmi               Yes      Active  Group 1
cnfimaalmparm         No       Any     Group 1
cnfimagrp             Yes      Active  Group 1
cnfimatst             No       Active  Group 1
cnfln                 Yes      Active  Group 1
cnfplpp               Yes      Active  Group 1
cnfportrscprtn        Yes      Active  Group 1
 
Type <CR> to continue, Q<CR> to stop:
 
cnfrscprtn            Yes      Active  Group 1
cnfslftst             Yes      Active  Any User
cnfsvcrange           Yes      Active  Group 1
cnfupcabr             Yes      Active  Group 2
cnfupccbr             Yes      Active  Group 2
cnfupcubr             Yes      Active  Group 2
cnfupcvbr             Yes      Active  Group 2
copychans             Yes      Active  Group 1
delaimgrp             Yes      Active  Group 1
delcdrscprtn          Yes      Active  Group 1
delchan               Yes      Active  Group 2
delchanloop           No       Active  Group 4
delchans              Yes      Active  Group 1
delcon                Yes      Active  Group 2
delimagrp             Yes      Active  Group 1
delln                 Yes      Active  Group 1
dellnsfmaimgrp        Yes      Active  Group 1
dellnsfmimagrp        Yes      Active  Group 1
delport               Yes      Active  Group 1
delrscprtn            Yes      Active  Group 1
dnport                Yes      Active  Group 1
dspaimgrp             No       Active  Group 1
dspaimgrpcnt          No       Active  Group 1
dspaimgrps            No       Active  Group 1
dspaimlncnt           No       Active  Group 1
dspalm                No       Any     Any User
dspalmcnf             No       Any     Any User
dspalmcnt             No       Any     Any User
dspalms               No       Any     Any User
dspcd                 No       Any     Any User
dspcderrs             No       Any     Any User
dspcdprtntype         Yes      Active  Group 2
dspcdrscprtn          Yes      Active  Group 1
dspchan               No       Any     Any User
dspchancnt            No       Any     Any User
dspchans              No       Any     Any User
dspcon                No       Any     Any User
dspcons               No       Any     Any User
dspilmi               No       Any     Any User
dspilmicnt            No       Any     Any User
dspimaalmparm         No       Any     Group 1
dspimagrp             No       Active  Group 1
dspimagrpcnt          No       Active  Group 1
dspimagrps            No       Active  Group 1
dspimainfo            No       Active  Any User
dspimaln              No       Any     Group 1
dspimalncnt           No       Active  Group 1
dspimatst             No       Any     Group 1
dsplcn                No       Any     Any User
dspln                 No       Any     Any User
dsplns                No       Any     Any User
dsploads              No       Active  Any User
dspmsgcnt             No       Any     Any User
dspplpp               Yes      Active  Group 1
dspport               No       Any     Any User
dspportcnt            No       Any     Any User
dspportq              No       Any     Any User
dspportqs             No       Any     Any User
dspportrscprtn        Yes      Active  Group 1
dspports              No       Any     Any User
dsprscprtn            Yes      Active  Group 1
dspsarcnt             No       Any     Any User
 
Type <CR> to continue, Q<CR> to stop:
 
dspsarcnts            No       Any     Any User
dspslftst             No       Any     Any User
dspslftsttbl          No       Any     Any User
dspstatparms          No       Any     Any User
dspsvcrange           Yes      Any     Any User
dsptotals             No       Any     Any User
memShow               No       Any     Any User
myid                  No       Any     Any User
oldcnfcdrscprtn       Yes      Active  Group 1
runslftstno           No       Any     Any User
setcmdc               No       Any     Any User
setpagemode           No       Any     Any User
tstcon                No       Active  Group 4
tstconseg             No       Active  Group 4
tstconsti             No       Active  Group 4
tstdelay              No       Active  Group 4
tstdelaysti           No       Active  Group 4
upport                Yes      Active  Group 1
version               No       Any     Any User
xaddcon               Yes      Active  Group 1
xclrchancnt           No       Any     Group 3
xclrportcnt           No       Any     Group 3
xcnfalmcnt            Yes      Active  Group 3
xcnfcon               Yes      Active  Group 1
xcnfilmi              Yes      Active  Group 1
xcnfportq             Yes      Active  Group 1
xdelcon               Yes      Active  Group 1
xdnport               Yes      Active  Group 1
xdspcon               No       Any     Any User
xdspcons              No       Any     Any User
xdspilmi              No       Any     Any User
xdspln                No       Any     Any User
xdsplns               No       Any     Any User
xdspport              No       Any     Any User
xdspportq             No       Any     Any User
xdspportqs            No       Any     Any User
xdspports             No       Any     Any User
xupport               Yes      Active  Group 1
 
spirit1.1.22.AUSM8.a >
 
 
Example 3
spirit1.1.20.FRSM.a > Help
Description

Display the commands available on the current card. In this case, the card is an FRSM.

System Response
Command               Logging  State   Priority
--------------------  -------  ------  -------------------------
?                     No       Any     Any User
Help                  No       Any     Any User
addcdrscprtn          Yes      Active  Group 1
addchan               Yes      Active  Group 2
addchanloop           No       Active  Group 4
addcon                Yes      Active  Group 2
addln                 Yes      Active  Group 1
addport               Yes      Active  Group 1
addrscprtn            Yes      Active  Group 1
clear                 No       Any     Any User
clralm                No       Any     Group 5
clralmcnt             No       Any     Group 5
clralmcnts            No       Any     Group 5
clralms               No       Any     Group 5
clrcderrs             No       Any     Super Group (0)
clrchancnt            No       Any     Group 5
clrchancnts           No       Any     Group 3
clrmsgcnt             No       Any     Group 5
clrportcnt            No       Any     Group 5
clrportcnts           No       Any     Group 5
clrsarcnt             No       Any     Group 5
clrsarcnts            No       Any     Group 5
clrscrn               No       Any     Any User
clrslftst             No       Any     Any User
cls                   No       Any     Any User
cnfcdprtntype         Yes      Active  Group 1
cnfcdrscprtn          Yes      Active  Group 1
cnfchancacoff         Yes      Active  Group 2
cnfchanegressq        Yes      Active  Group 2
cnfchanfst            Yes      Active  Group 2
cnfchaningressq       Yes      Active  Group 2
cnfchanmap            Yes      Active  Group 2
cnfchanpol            Yes      Active  Group 2
cnfcon                Yes      Active  Group 2
cnffst                Yes      Active  Super Group (0)
cnfln                 Yes      Active  Group 1
cnfoamlpbk            No       Any     Any User
cnfport               Yes      Active  Group 1
cnfportcllm           Yes      Active  Group 1
cnfportrscprtn        Yes      Active  Group 1
cnfrscprtn            Yes      Active  Group 1
cnfslftst             Yes      Any     Any User
cnftrafficgen         No       Any     Any User
cnfunit391            No       Active  Super Group (0)
copychans             Yes      Active  Group 1
copyports             Yes      Active  Group 1
delcdrscprtn          Yes      Active  Group 1
delchan               Yes      Active  Group 2
delchanloop           No       Active  Group 4
delchans              Yes      Active  Group 1
 
Type <CR> to continue, Q<CR> to stop:
 
delcon                Yes      Active  Group 2
delln                 Yes      Active  Group 1
delport               Yes      Active  Group 1
delports              Yes      Active  Group 1
downport              Yes      Active  Group 2
dspalm                No       Any     Any User
dspalmcnf             No       Any     Any User
dspalmcnt             No       Any     Any User
dspalms               No       Any     Any User
dspbufoverflow        No       Any     Super Group (0)
dspcd                 No       Any     Any User
dspcderrs             No       Any     Any User
dspcdprtntype         No       Any     Any User
dspcdrscprtn          No       Any     Any User
dspchan               No       Any     Any User
dspchancnt            No       Any     Any User
dspchanmap            No       Any     Any User
dspchans              No       Any     Any User
dspchstats            No       Any     Any User
dspcon                No       Any     Any User
dspcons               No       Any     Any User
dspfst                Yes      Active  Group 4
dsplcn                No       Active  Any User
dspln                 No       Any     Any User
dsplns                No       Any     Any User
dspmaptbl             No       Any     Any User
dspmsgcnt             No       Any     Any User
dspoamlpbk            No       Any     Any User
dspport               No       Any     Any User
dspportcnt            No       Any     Any User
dspportrscprtn        No       Any     Any User
dspports              No       Any     Any User
dspportstats          No       Any     Any User
dsprscprtn            No       Any     Any User
dspsarcnt             No       Any     Any User
dspsarcnts            No       Any     Any User
dspservrate           No       Any     Super Group (0)
dspslftst             No       Any     Any User
dspslftsttbl          No       Any     Any User
dspstatparms          No       Any     Any User
dsptotals             No       Any     Any User
dsptrafficgen         No       Any     Any User
dspunit391            No       Active  Any User
memShow               No       Any     Any User
myid                  No       Any     Any User
oldcnfcdrscprtn       Yes      Active  Group 1
runslftstno           No       Any     Any User
setcmdc               No       Any     Any User
setpagemode           No       Any     Any User
tstcon                No       Active  Group 4
tstconsti             No       Active  Group 4
tstdelay              No       Active  Group 4
tstdelaysti           No       Active  Group 4
upport                Yes      Active  Group 2
version               No       Any     Any User
xclrchancnt           No       Any     Group 3
xclrportcnt           No       Any     Group 3
xcnfalmcnt            Yes      Active  Group 3
xcnfchan              Yes      Active  Group 2
xcnfport              Yes      Active  Group 1
xdspchan              No       Any     Any User
xdspchancnt           No       Any     Any User
 
Type <CR> to continue, Q<CR> to stop:
 
xdspchans             No       Any     Any User
xdspln                No       Any     Any User
xdsplns               No       Any     Any User
xdspport              No       Any     Any User
xdspportcnt           No       Any     Any User
xdspports             No       Any     Any User
 
spirit1.1.20.FRSM.a >
Example 4

Help

Description

Display the commands available on the current card. In this case, the card is an VISM.

System Response
?
Help
addchan
addcon
addendpt
addln
addlnloop
chkflash
clralm
clralmcnt
clralmcnts
clralms
clrmsgcnt
clrsarcnt
clrsarcnts
clrscrn
clrtaskinfo
cnfalm
cnfcompsize
cnfcompvad
cnfdomain
cnfecancnt
cnfecanidle
cnfecannoise
cnfecannr
cnfecannrn
cnfecanrec
cnfecantail
cnfecantone
cnfln
cnfsuip
cnfvismip
delchan
delcon
delendpt
delln
dellnloop
dmShellConn
dspalm
dspalmcnf
 
 
Type <CR> to continue, Q<CR> to stop:
 
dspalmcnt
dspalms
dspcarddsp
dspcd
dspchan
dspchans
dspcon
dspcons
dspdomain
dspendpt
dspendpts
dsplinedsp
dspln
dsplns
dspmsgcnt
dspsarcnt
dspsarcnts
dspsuip
dsptaskinfo
dspvismip
i
memShow
shellConn
version
 
Example 5
spirit1.1.21.CESM.a > Help
Description

Display the commands available on the current card. In this case, the card is a CESM.

System Response
 
Command               Logging  State   Priority
--------------------  -------  ------  -------------------------
?                     No       Any     Any User
Help                  No       Any     Any User
addcdrscprtn          No       Any     Any User
addchan               Yes      Active  Group 2
addcon                Yes      Active  Group 2
addln                 Yes      Active  Group 1
addport               Yes      Active  Group 1
clear                 No       Any     Any User
clralm                No       Any     Group 5
clralmcnt             No       Any     Group 5
clralmcnts            No       Any     Group 5
clralms               No       Any     Group 5
clrcderrs             No       Any     Super Group (0)
clrchancnt            No       Any     Group 5
clrchancnts           No       Any     Group 3
clrmsgcnt             No       Any     Group 5
clrsarcnt             No       Any     Group 5
clrsarcnts            No       Any     Group 5
clrscrn               No       Any     Any User
clrslftst             No       Any     Any User
cls                   No       Any     Any User
cnfcdprtntype         No       Any     Any User
cnfcdrscprtn          No       Any     Any User
cnfchan               Yes      Active  Group 2
cnfcon                Yes      Active  Group 2
cnfln                 Yes      Active  Group 1
cnfportrscprtn        No       Any     Any User
cnfslftst             Yes      Active  Any User
cnfswparms            No       Any     Any User
delcdrscprtn          No       Any     Any User
delchan               Yes      Active  Group 2
delchans              Yes      Active  Group 1
delcon                Yes      Active  Group 2
delln                 Yes      Active  Group 1
delport               Yes      Active  Group 1
delports              Yes      Active  Group 1
dspalm                No       Any     Any User
dspalmcnf             No       Any     Any User
dspalmcnt             No       Any     Any User
dspalms               No       Any     Any User
dspcd                 No       Any     Any User
dspcderrs             No       Any     Any User
dspcdrscprtn          No       Any     Any User
dspchan               No       Any     Any User
dspchancnt            No       Any     Any User
dspchans              No       Any     Any User
dspcon                No       Any     Any User
 
Type <CR> to continue, Q<CR> to stop:
 
dspcons               No       Any     Any User
dsplcn                No       Active  Any User
dspln                 No       Any     Any User
dsplns                No       Any     Any User
dspmsgcnt             No       Any     Any User
dspport               No       Any     Any User
dspportrscprtn        No       Any     Any User
dspports              No       Any     Any User
dspsarcnt             No       Any     Any User
dspsarcnts            No       Any     Any User
dspslftst             No       Any     Any User
dspslftsttbl          No       Any     Any User
dspstatparms          No       Any     Any User
memShow               No       Any     Any User
myid                  No       Any     Any User
oldcnfcdrscprtn       No       Any     Any User
oldcnfportrscprtn     No       Any     Any User
runslftstno           No       Any     Any User
setpagemode           No       Any     Any User
tstchan               No       Active  Group 4
tstchansti            No       Active  Group 4
tstcon                No       Active  Group 4
tstconsti             No       Active  Group 4
tstdelay              No       Active  Group 4
tstdelaysti           No       Active  Group 4
version               No       Any     Any User
xclrchancnt           No       Any     Group 3
xcnfalmcnt            Yes      Active  Group 3
xcnfchan              Yes      Active  Group 2
xcnfport              Yes      Active  Group 1
xdspchan              No       Any     Any User
xdspchancnt           No       Any     Any User
xdspchans             No       Any     Any User
xdspln                No       Any     Any User
xdsplns               No       Any     Any User
xdspport              No       Any     Any User
xdspports             No       Any     Any User
 
spirit1.1.21.CESM.a >

history

The history command displays the last 10 commands executed on the current card.

Full Name

Display Command History

Syntax

history

Related Commands

cmdhistory

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > history
Description

Display the last 10 commands executed on the PXM card.

System Response
Size of cmdHistory is currently 10 line(s)
  1 dspconcnt 2.39.45
  2 dsplmistats
  3 dsplmiloop
  4 dsplm
  5 clrportcnt
  6 dspportcnts
  7 dspportcnt
  8 dspportcnt 1
  9 dsplmistats
 10 history
 

ifShow

The ifShow command displays the contents of all the currently configured interfaces.

Full Name

Show Interfaces

Syntax

ifShow

Related Commands

memShow, routeShow

Cards on which the command executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > ifShow

System Response

A typical response is shown below:

lnPci (unit number 0):
     Flags: (0x63) UP BROADCAST ARP RUNNING
     Internet address: 172.29.23.149
     Broadcast address: 172.29.23.255
     Netmask 0xffff0000 Subnetmask 0xffffff00
     Ethernet address is 00:c0:43:00:2d:c7
     Metric is 0
     Maximum Transfer Unit size is 1500
     599468 packets received; 34476 packets sent
     0 input errors; 0 output errors
     0 collisions
lo (unit number 0):
     Flags: (0x69) UP LOOPBACK ARP RUNNING
     Internet address: 127.0.0.1
     Netmask 0xff000000 Subnetmask 0xff000000
     Metric is 0
     Maximum Transfer Unit size is 4096
     4 packets received; 4 packets sent
     0 input errors; 0 output errors
     0 collisions
sl (unit number 0):
     Flags: (0x71) UP POINT-TO-POINT ARP RUNNING
     Internet address: 0.0.0.0
     Destination Internet address: 0.0.0.0
     Netmask 0xff000000 Subnetmask 0xff000000
     Metric is 0
     Maximum Transfer Unit size is 576
     0 packets received; 0 packets sent
     0 input errors; 0 output errors
     0 collisions
atm (unit number 0):
     Flags: (0x43) UP BROADCAST TRAILERS ARP RUNNING
     Internet address: 172.1.1.149
     Broadcast address: 172.1.1.255
     Netmask 0xffff0000 Subnetmask 0xffffff00
     Ethernet address is 00:00:00:00:00:00
     Metric is 0
     Maximum Transfer Unit size is 1500
     0 packets received; 47272 packets sent
     0 input errors; 47272 output errors
     0 collisions
 
spirit4.1.8.PXM.a >

install

The install command aborts copying the selected firmware file into the PXM or optionally, to a selected service module.

Full Name

Install the firmware load

Syntax
install [sm <slot>] <version>

where:

slot

is the SM card must match its name on the FW directory, (CESM=sm90.fw, FRSM=sm35.fw, AUSM=sm50.fw, FRSM-VHS=sm130.fw).

version

is the firmware file name. The SM card must match its name on the FW directory, (CESM=sm90.fw, FRSM=sm35.fw, AUSM=sm50.fw, FRSM-VHS=sm130.fw).

Related Commands
abort, commit, copy, newrev
Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
spirit4.1.8.PXM.a > install pxm_1.0.00Ef.fw
Description

Begin loading firmware file named pxm_1.0.00Ef.fw.

System Response

none

logout

The logout command lets you exit the current CLI shell.

Full Name

Log Out

Syntax

logout

Related Commands

bye, exit

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: Yes State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > logout
Description

Log out of the current CLI shell.

System Response
(session ended)

memShow

The memShow command displays the current memory map.

Full Name

Show memory

Syntax

memShow

Related Commands

ifShow, routeShow

Cards on which the command executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > memShow

System Response

A typical response is shown below:

  status   bytes    blocks   avg block  max block
 ------ --------- -------- ---------- ----------
current
   free   2967104       37      80192   2879008
  alloc   2561600     1774       1443        -
cumulative
  alloc  241511616  1019558        236        -
 
spirit4.1.8.PXM.a >

myid

The myid command displays information about the user of the current terminal session.

Full Name

My ID

Syntax

myid

Related Commands

none

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.7.PXM.a > myid
Description

Display the login name of the current user---"stratacat" in this case.

System Response
 
    User ID:        stratacat
    Access Level:   GROUP1
    Terminal Port:  telnet.01
 
spirit.1.7.PXM.a >
 

newrev

This command is the second step in the upgrade / downgrade procedure and assumes that the install command has been successfully completed. The "sm <slot>" parameter is optional which is given only when a service module image is being upgraded.

Syntax
newrev [sm <slot>] <version>

where:

<slot>

is the service module slot that needs to be upgraded / downgraded.

<version>

is the version of the new image. The SM card must match its name on the FW directory, (CESM=sm90.fw, FRSM=sm35.fw, AUSM=sm50.fw, FRSM-VHS=sm130.fw).

Related Commands
abort, commit, copy, install
Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: Any

passwd

The passwd command configures the password. If you enter a user-name rather than a password, you can modify the password of that user account.

Full Name

Password

Syntax

passwd [userName]

where:

userName

is the ID of a user.

Related Commands

dspusers

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Any Privilege: Any

Example
spirit.1.7.PXM.a > passwd
 
Description

Configure the password for your account. If you enter a username to modify a password for, it must be a user with a lower privilege level. As shown below, no passwords are echoed to the screen.

System Response
Enter password:
Re-enter password:
 
 
spirit.1.7.PXM.a >

printrev

This command displays the primary and secondary versions of firmware saved in the BRAM.

Full Name

Display Firmware Version

Syntax
printrev
Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > printrev
Description

Display the version of firmware running in both PXM cards.

System Response
primary : 1.0.00
secondary : 1.0.00
 
spirit4.1.8.PXM.a >

resetcd

The resetcd command resets either the hardware of a selected service module or the failure history of the current card. Without a slot number, the command resets only the failure history on the PXM. With a slot number, the resetcd command resets the card in the specified slot.

Full Name

Reset Card

Syntax

resetcd [slot number]

where:

slot number

is the optional slot number of a specific card. The range is 1-32.

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 1-3

routeShow

The routeShow command shows the current IP routing of the network layer of the operating system.

Full Name

Show Routing

Syntax

routeShow

Related Commands

routestatShow

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > routeShow
 
Description

Display the current IP routing of the network layer of the operating system.

System Response
 
ROUTE NET TABLE
destination      gateway          flags  Refcnt  Use           Interface
------------------------------------------------------------------------
0.0.0.0          172.29.23.149    1      1       21778         lnPci0
0.0.0.0          172.29.23.1      3      0       2755          lnPci0
172.1.1.0        172.1.1.149      1      0       0             atm0
172.29.23.0      172.29.23.149    1      2       5275          lnPci0
------------------------------------------------------------------------
 
ROUTE HOST TABLE
destination      gateway          flags  Refcnt  Use           Interface
------------------------------------------------------------------------
0.0.0.0          0.0.0.0          5      0       0             sl0
127.0.0.1        127.0.0.1        5      1       0             lo0
172.29.23.3      172.1.1.149      5      0       3555          atm0
172.29.23.5      172.1.1.149      5      0       3304          atm0
172.29.23.7      172.1.1.149      5      0       3335          atm0
171.71.29.18     172.1.1.149      5      0       3304          atm0
172.29.23.18     172.1.1.149      5      0       3304          atm0
172.29.23.28     172.1.1.149      5      0       6127          atm0
172.29.23.29     172.1.1.149      5      1       6065          atm0
171.71.29.32     172.1.1.149      5      0       5842          atm0
171.71.29.44     172.1.1.149      5      0       3304          atm0
172.29.23.53     172.1.1.149      5      0       3304          atm0
171.71.29.59     172.1.1.149      5      0       3304          atm0
171.71.28.126    172.1.1.149      5      0       3309          atm0
------------------------------------------------------------------------
 
spirit4.1.8.PXM.a >

routestatShow

The routestatShow command shows the current IP routing statistics for the network layer of the operating system.

Full Name

Show Routing Statistics

Syntax

routestatShow

Related Commands

routeShow

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.8.PXM.a > routestatShow
 
Description

Display the current IP routing statistics for the network layer of the operating system.

System Response
  
routing:
        0 bad routing redirect
        0 dynamically created route
        0 new gateway due to redirects
        0 destination found unreachable
        11095 uses of a wildcard route
 
spirit4.1.8.PXM.a >
 
 

runslftstno

The runslftstno command runs the self test for the specified self test number on the current card.

Full Name

Run Self Test Number

Syntax

runslftstno <Test #>

where

Test #

Test # is number of the test to be run. If this parameter is omitted, all tests are run

:

Related Commands

none

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: Yes State: Active Privilege: 1-2

Example 1
spirit.1.19.AUSM8.a > runslftstno
Description

Run all self tests on the current card (an AUSM).

System Response
Test #  Test Name          Thold Fail Pass Last Enab Destr Card Rst
  1     DRAM access test     1     0    0    P    Y    N     Y
  2     SRAM access test     1     0    0    P    Y    N     Y
  3     GRAM access test     1     0    0    P    Y    N     Y
  4     BRAM checksum test   1     0    0    P    Y    Y     Y
  5     CODE checksum test   1     0    0    P    Y    N     Y
  6     Line loopback test   1     0    0    P    Y    Y     Y
  7     CellBus test         1     0    0    P    Y    N     N
  8     DPRAM test           1     0    0    P    Y    N     Y
  9     CSERAM test          1     0    0    P    Y    N     Y
 10     CAM test             1     0    0    P    Y    Y     Y
 11     IMA grp lpbk test    1     0    0    P    Y    Y     Y
runslftstno "Test #"
 spirit.1.19.AUSM8.a >
Example 2
spirit.1.1.FRSM.a > runslftstno
 
Description

Run all self tests on the current card (an FRSM).

System Response
Test #  Test Name          Thold Fail Pass Last Enab Destr Card Rst
  1     DRAM access test     1     0    0    P    Y    N     Y
  2     SRAM access test     1     0    0    P    Y    N     Y
  3     GRAM access test     1     0    0    P    Y    N     Y
  4     BRAM checksum test   1     0    0    P    Y    N     Y
  5     CODE checksum test   1     0    0    P    Y    N     Y
  6     Line loopback test   1     0    0    P    Y    Y     Y
  7     M32 test             1     0    0    P    Y    Y     N
  8     Data loopback test   1     0    0    P    N    Y     Y
  9     CellBus test         1     0    0    P    Y    N     N
runslftstno "Test #"
 
spirit.1.1.FRSM.a >
Example 3
spirit.1.3.VHS2CT3.a > runslftstno
Description

Run all self tests on the current card (an FRSM-2CT3).

System Response
Test #  Test Name           Thold Fail Pass Last Enab Destr Card Rst
  1     CPU DRAM access test       1     0    0    P    Y    N     Y
  2     SAR self test              1     0    0    P    Y    N     Y
  3     ISE self test              1     0    0    P    Y    N     Y
  4     ESE self test              1     0    0    P    Y    N     Y
  5     CODE checksum test         1     0    0    P    Y    N     Y
  6     Line loopback test         1     0    0    P    Y    Y     Y
  7     FREEDM test                1     0    0    P    Y    Y     Y
  8     Data loopback test         1     0    0    P    Y    Y     Y
  9     CellBus test               1     0    0    P    Y    N     N
runslftstno "Test #"
spirit.1.3.VHS2CT3.a > runslftstno
 
Example 4
spirit.1.3.VHS2CT3.a > runslftstno 1
 
Description

Run the self test with the specified self test number on the current card.

System Response
Test Number 1 Result: PASS
 

sesntimeout

The sesntimeout command lets you specify the current session's maximum idle time in seconds. If you do not specify a timeout period in seconds, the system displays the current timeout. To disable the session timeout function, enter a 0.

Full Name

Session Timeout

Syntax

sesntimeout [time_out]

where time_out is the number of seconds a session can be idle before the system logs out the user.

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: SuperUser

Example 1
spirit.1.7.PXM.a > sesntimeout
Description

Display the current timeout.

System Response
The timeout period for this session is currently 600 second(s)
 
Example 2
spirit.1.7.PXM.a > sesntimeout 720
Description

Set the session timeout threshold to 12 minutes (720 seconds).

System Response
The timeout period for this session is now set to 720 second(s)
 
spirit.1.7.PXM.a >

softswitch

This command switches control from the primary service module to the secondary (or redundant) service module. The primary service module will reboot and will come up in standby mode. Use the switchback command to revert to normal operation after a softswitch.

Full Name

Switch to Redundant from Primary

Syntax

softswitch <PrimarySlotNum> <SecondarySlotNum>

where:

<PrimarySlotNum>

slot number of the slot containing the primary card of the card pair. Range = 1-6, 9-14, 17-22, or 25-30, primary or secondary card must be in active state.

<SecondarySlotNum>

slot number of the slot containing the secondary card of the card pair. Range = 1-6, 9-14, 17-22, or 25-30, primary or secondary card must be in active state.

Related Commands

switchback, addred, delred, dspred

Cards on which the command executes

PXM

Attributes

Log: No State: Active Privilege: Any


switchapsln

The switchapsln command lets you control APS switching actions.

Full Name

Switch APS Line.

Syntax

switchapsln <option>

where:

option

indicates the action to apply. The range for option is 1-5. Enter as follows:

1 for clear

2 for forced

3 for manual

4 for lock-out

5 for service

Related Commands

addapsln, cnfapsln, delapsln, dspapsln

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 1

switchback

Use this command to revert to normal operation after a softswitch. the switchback command switches control from the secondary (or redundant) service module back to the primary service module. The secondary (or redundant) service module will reboot and will come up in standby mode

Full Name

Switch Back to Primary from Redundant

Syntax

switchback <PrimarySlotNum> <SecondarySlotNum>

where:

<PrimarySlotNum>

slot number of the slot containing the primary card of the card pair. Range = 1-6, 9-14, 17-22, or 25-30, primary or secondary card must be in active state.

<SecondarySlotNum>

slot number of the slot containing the secondary card of the card pair. Range = 1-6, 9-14, 17-22, or 25-30, primary or secondary card must be in active state.

Related Commands

softswitch, addred, delred, dspred

Cards on which the command executes

PXM

Attributes

Log: No State: Active Privilege: Any

switchcc

The switchcc command switches control of the MGX 8850 shelf from the active PXM to the standby PXM. If a standby PXM is not available, the command is not executed.

During a config copy, this command is disabled. If the command is attempted during a config copy, a "Can't execute, BRAM or FLASH is being updated" message is displayed.

Full Name

Switch Core Cards

Syntax

switchcc

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: 1-3

timeout

The timeout command lets you specify the current session's maximum idle time in seconds. If you do not specify a timeout period in seconds, the system displays the current timeout. To disable the session timeout function, enter a 0.

Full Name

Session Timeout

Syntax

timeout [time_out]

where time_out is the number of seconds a session can be idle before the system logs out the user.

Related Commands
sasntimeout
Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: SuperUser

Example 1
spirit.1.7.PXM.a > timeout
Description

Display the current timeout.

System Response
The timeout period for this session is currently 600 second(s)
 
Example 2
spirit.1.7.PXM.a > timeout 720
Description

Set the session timeout threshold to 12 minutes (720 seconds).

System Response
The timeout period for this session is now set to 720 second(s)
 
spirit.1.7.PXM.a >
 

tstcon

Tests the integrity of a connection between an MGX 8850 card and a remote end within the WAN switching network by sending a single collection of supervisory cells to the remote end. The terminal displays only a pass or fail message.

Full Name

Test Connection

Syntax for Service Modules

tstcon <channel number>

where:

channel number

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For PXM, 16-1024

· For AUSM, 16-1015

· For CESM-8T1/E1, 32-279

· For CESM-T3/E3, one connection starting at 32

Syntax for PXM

tstcon <con_id>

where:

con_id

A string in the format port.vpi.vci where:

· port is in the range 1 through n, where n is the highest numbered port on the card.

· vpi is the virtual path interface, in the range 1-4095

· vci is the virtual channel interface, in the range 1-65535

Related Commands

dspcons, tstconseg, tstdelay

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: 1-4

tstconseg

Tests the integrity of a connection between an MGX 8850 card and service equipment (CPE) by sending a single collection of supervisory cells to the remote end. The terminal displays only a pass or fail message.

Full Name

Test Connection Segment

Syntax

tstconseg <channel number>

where:

channel number

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For PXM, 16-4111

· For AUSM, 16-1015

Related Commands

dspcons, tstcon

Cards on Which This Command Executes

PXM, FRSM, AUSM

Attributes

Log: No State: Any Privilege: 1-4

tstdelay

Externally tests the integrity of a connection by sending a single collection of supervisory cells to the remote end to the network and back. The terminal displays a pass or fail message and the round trip time in milliseconds.

Full Name

Test Round Trip Delay

Syntax for Service Modules

tstdelay <channel number>

where:

channel number

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For AUSM, 16-1015

· For CESM-8T1/E1, 32-279

· For CESM-T3/E3, one connection starting at 32.

Syntax for PXM

tstdelay <con_id>

where:

con_id

A string in the format port.vpi.vci where:

· port is in the range 1 through n, where n is the highest numbered port on the card.

· vpi is the virtual path interface, in the range 1-4095

· vci is the virtual channel interface, in the range 1-65535

Related Commands

dspcons, tstcon

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM

Attributes

Log: No State: Active Privilege: 1-4

Example
MGX 880061.1.10.AUSM.a > tstdelay 16
Description

Test the delay for a round trip to and from the network on channel 16.

System Response
TestDelay in progress.
 
TestDelay Passed with 2 ms.
 
MGX 880061.1.10.AUSM.a >
 

uncnfifastrk

The PAR command uncnfifastrk lets you return a line on the PXM to working as a routing trunk.

Full Name

Unconfigure Interface as Trunk

Syntax

uncnfifastrk <slot.port> <iftype>

where:

slot.port

is the slot and port number of the line you want to serve as the trunk.Typically, slot is 7. The range for port is 1-n, where n is the highest numbered port on the card.

iftype

is the type of trunk---"ftrk" for a feeder trunk or "rtrk" for a routing trunk. The default is "rtrk."

Related Commands

cnfifastrk

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example
MGX-01.1.7.PXM.a > uncnfifastrk 7.1 rtrk
Description

Return the line on port 1 in slot 7 to use as a routing trunk.

System Response

none

upcon

The upcon command ups a connection that was previously downed by the dncon command. (The typical purpose of dncon is some form of operational modification or troubleshooting.)

Full Name

Up Connection

Syntax

upcon <slot >.<port>.<vpi>.<vci>

where the connection specification has the format slot.port.vpi.vci, where:

The variable slot is either 1 through 6, 9 through 14, 17 through 22, or 25 through 31

port -- a number between 1 and 255

vpi -- a number between 0 and 4095

vci -- a number between 0 and 65535

Related Commands

dncon

Cards on Which This Command Executes

PXM, AUSM, FRSM, VISM, CESM

Attributes

Log: No State: Active Privilege: 1

upif

The upif command adds a logical interface to a broadband port on a PXM. The purpose of configuring logical interfaces for a line is to create a structure for resource partitioning. The network control applications (PAR, Tag, and so on) require resources linked to the logical interfaces.

A PXM can have 1-32 logical interfaces regardless of the number of physical lines. With multiple lines serving as uplinks, you can divide the 32 logical interfaces between the active lines according to need, yet each line would still have the full range of VPIs and VCIs. In summary, the number of logical interfaces per line can vary, but the maximum number of VPIs and VCIs is fixed (with the actual range subject to your configuration). To change the configuration of an existing logical interface on the PXM, use the cnfif command.


Note On a virtual trunk, the min_vpi and max_vpi should be the same. Only a routing node can support virtual trunking.
Full Name

Up Interface

Syntax

upif <if_num> <line_num> <pct_bw> <min_vpi> <max_vpi>

where:

if_num

is the number of the logical interface. The range for if_num is 1-32

line_num

is the number of the line on the PXM line module. The range for line_num
is 1-4 (1 port on the OC-12 card, 4 ports on the OC-3 card, and 2 ports on the T3/E3 card).

pct_bw

is the percent of the line bandwidth for the logical interface. The pct_bw range is 0-100. The value applies to both the ingress and egress.

min_vpi

is the minimum VPI value. The range is 0-255 for UNI or 0-4095 for NNI. Typically, the UNI range applies to a line connecting a stand-alone node to a workstation.

max_vpi

is the maximum VPI value. The range is 0-255 for UNI or 0-4095 for NNI. Typically, the UNI range applies to a line connecting a stand-alone node to a workstation.

Related Commands

upif

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: 1-4

Example
upif 1 1 100 1 2000
Description

The first "1" is the logical interface number; the second "1" is the line number on the PXM back card to which you are assigning this logical interface number; "100" is the percentage of bandwidth available to this logical interface in both directions; and the VPI range is 1-2000.

System Response

none

upport

The upport command activates ("ups") a port. No messages appear on screen unless an error occurs.

Full Name

Up port

Syntax

upport <PortNum>

where:

PortNum

Port Number = 1-8

Related Commands

dnport

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1

users

Lists the users logged into the current card. The screen display shows the means through which each user logged into the switch, the slot number of the current card, and the login name of the users.

Full Name

Display the names of all users currently logged in to the switch

Syntax

users

Related Commands

none

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.7.PXM.a > users
Description

Display the users logged into the switch.

System Response
    Port        Slot      Idle       UserId       From
    -------------------------------------------------------------
    telnet.01 *    7     0:00:00     cisco        171.71.25.240
    telnet.02      3     0:07:03     cisco        171.71.25.240
 

version

The version command displays different types of version-related information, such as firmware version, operating system kernel version, the date of the software build, and so on (refer to screen examples).

Full Name

Display Versions

Syntax

version

Related Commands

none

Cards on Which This Command Executes

PXM, FRSM, AUSM, CESM, VISM

Attributes

Log: No State: Any Privilege: Any

Example 1
spirit.1.7.PXM.a > version
Description

Display version information on the current card (PXM).

System Response
    VxWorks (for MGX 8850) version 5.3.1.
    Kernel: WIND version 2.5.
    Made on Feb 13 1999, 07:40:57.
    Boot line:
    lnPci(0,0) e=172.29.37.40 g=172.29.37.1
    PXM firmware version : 1.0.00cp1
    Boot Image Version   : 1.0.00av
    
Example 2
MGX 88003.1.11.FRSM.a > version
Description

Display version information on the current card (FRSM).

System Response
***** Cisco Systems, Inc. MGX 8800 FRSM Card *****
    Firmware Version    = eqa2.0.1g
    Backup Boot version = model-B BT_2.0.0
    PXMFRSM Xilinx file = frsm025.h
VxWorks (for STRATACOM) version 5.1.1-R3000.
Kernel: WIND version 2.4.
Made on Wed Jan 13 19:45:10 PST 1999.
Boot line:
 
MGX 88003.1.11.FRSM.a >
 
 
 
Example 3
spirit.1.5.VISM8.a > version
Description

Display version information on the current card (VISM).

System Response
***** Cisco Systems. AXIS VISM Card *****
    Firmware Version    = rangar
    Backup Boot version = 3.2.02
    Xilinx Firmware version = 10/ 2/1998
    DSPCOM FPGA version     =  1/20/1999
    DSPM Firmware Details:
        Major Release   = 3
        Minor Release   = 0
        Build number    = 12
    DSPM ecan Firmware Details:
        Major Release   = 7
        Minor Release   = 3
        Build number    = 9e1
VxWorks (for R5k PDC) version 5.3.1.
Kernel: WIND version 2.5.
Made on Mar  9 1999, 14:19:21.
Boot line:
 
 
spirit.1.5.VISM8.a >
Example 4
MGX 88003.1.14.AUSM.a > version

Description

Display version information on the current card (AUSM).

System Response
MGX 88003.1.14.AUSM.a > version
 
***** Cisco Systems, Inc. MGX 8800 AUSM Card *****
    Firmware Version    = model-A 2.0.00
    Backup Boot version = model-A BT_eqa2.0.1
    AUSM Xilinx file    = ausmfract.h
VxWorks (for STRATACOM) version 5.1.1-R3000.
Kernel: WIND version 2.4.
Made on Thu Jan 21 17:57:59 GMT 1999.
Boot line:
 
MGX 88003.1.14.AUSM.a >
 

who

The who command lists the users logged into the current card. The screen display shows the means through which each user logged into the shelf, the slot number of the current card, and the login name of each user.

Full Name

Who

Syntax

who

Related Commands

adduser, deluser, whoami

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example

spirit.1.7.PXM.a > who
 
Description

Display the users logged into the current card.

System Response
 
    Port        Slot      Idle       UserId       From
    -------------------------------------------------------------
    telnet.01 *    7     0:00:00     cisco        171.71.25.240
 
spirit.1.7.PXM.a >
 

whoami

The whoami command displays information about the user of the current terminal session.

Full Name

Who Am I

Syntax

whoami

Related Commands

adduser, deluser, who

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.7.PXM.a > whoami
 
Description

Display information about the user of the current terminal session.

System Response
    User ID:        cisco
    Access Level:   CISCO_GP
    Terminal Port:  telnet.01
 

xaddcon

This command adds a connection to the current AUSM. No messages appear on screen after command entry unless the command cannot execute as entered.

Full Name

Add Connection

Syntax

xaddcon <channel number> <connection type> <port number> <vpi> <vci> <service type> <egress queue number>

where:

<channel number>

channel number has a range of 16-1015

<connection type>

connection type is either 1 for VPP or 2 for VCC

<port number>

port number is in the range 1-8

<vpi>

vpi has a value in the range 0-255

<vci>

vci has a value in the range 0-65535

<service type>

service type can be: 1 = CBR, 2 = VBR, and 3 = ABR

<egress queue number>

egress queue number can be specified as 1-12 and 0 is for the default in addcon

Related Commands

delcon, dspcons, dspcon

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

Example
MGX 88003.1.14.AUSM.a > xaddcon 16 2 1 1 1 3 1
Description

Add a VCC connection to channel 16 on port 1 with vpi=1, vci=1, ABR service type, and an egress queue number of 1

System Response

No system response unless an error occurs.

xclrchancnt

This command clears the channel counters for a specified frame relay channel on an FRSM, CESM, or AUSM. Counting resumes after the command executes.

Full Name

Clear Channel Counters

Syntax

xclrchancnt -chn <channel number>

where:

<channel number>

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For AUSM, 16-1015

· For CESM-8T1/E1, 32-279

· For CESM-T3/E3, one connection starting at 32

Related Commands

dspchan, clrchancnts, dspchancnt

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attribute

Log: No State: Any Privilege: 1-5

System Response

No system response unless an error occurs.

xclrportcnt

This command is used to clear the values of a port's counters on the current AUSM or FRSM.

No message appears upon successful execution of the command.

Full Name

Clear Port Counters

Syntax

xclrportcnt -pt <port number>

where:

On an AUSM, <port number> is in the range 1-8.

On an FRSM, <port number> is in the range 1-192 for T1, 1-248 for E1.

Related Commands

clrportcnts, xdspportcnt, xdspportcnt, dspportcnt

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: No State: Any Privilege: 1-5

System Response

No system response unless an error occurs.

xcnfalm

This command configures extended alarm counters and statistics for the specified line.

Full Name

Configure Extended Alarm Counters and Statistics

Syntax

xcnfalm -ds1 <LineNum> -red <RedSeverity> -rai <RAISeverity> -neu <NEAlarmUpcount> -ned <NEAlarmDncount> -net <NEAlarmThreshold> -feu <FEAlarmUpcount> -fed <FEAlarmDncount> -fet <FEAlarmThreshold>

where:

<LineNum>

LineNum is the line number only, which is a number in the range 1-n, where n is the maximum number of lines on the interface.

<RedSeverity>

RedSeverity is a number in the range 1-2, where 1: Minor, 2: Major.

<RAISeverity>

RAISeverity is a number in the range 1-2, where 1: Minor, 2: Major.

<NEAlarmUpcount>

NEAlarmUpcount is a number in the range 1-65335.

<NEAlarmDncount>

NEAlarmDncount is a number in the range 1-65335.

<NEAlarmThreshold>

NEAlarmThreshold is a number in the range 1-65335.

<FEAlarmUpcount>

FEAlarmUpcount is a number in the range 1-65335.

<FEAlarmDncount>

FEAlarmDncount is a number in the range 1-65335.

<FEAlarmThreshold>

FEAlarmThreshold is a number in the range 1-65335.

Related Commands

xcnfalmcnt

Cards on which the command executes

FRSM, AUSM, CESM

Attributes

Log: Yes State: Active Privilege: 1

Example
MGX 88003.1.14.AUSM.a > xcnfalm -ds1 1 -red 1 -rai 1 -neu 100 -ned 100 -net 100 -feu 100 -fed 100 -fet 100
  
Description

To configure the ds1 line 1 alarms so that RED and RAI are both minor alarms, and the up and down counts and threshold for both FE and NE are all set to 100.

System Response

No system response unless an error occurs.

xcnfalmcnt

This command configures the extended alarm counters for the specified line.

Full Name

Configure Alarm Counters.

Syntax

xcnfalmcnt -ds1 <LineNum> -sev <StatisticalAlarmSeverity> -lcv15 <lCV15minThreshold> -lcv24 <lCV24hrThreshold> -les15 <lES15minThreshold> -les24 <lES24hrThreshold> -lses15 <lSES15minThreshold> -lses24 <lSES24hrThreshold> -crc15 <cRC15MinThreshold> -crc24 <cRC24HrThreshold> -crces15 <cRCES15MinThreshold> -crces24 <cRCES24HrThreshold> -crcses15 <cRCSES15MinThreshold> -crcses24 <cRCSES24hrThreshold> -sefs15 <sEFS15minThreshold> -sefs24 <sEFS24hrThreshold> -aiss15 <aISS15minThreshold> -aiss24 <aISS24hrThreshold> -uas15 <uAS15minThreshold> -uas24 <uAS24hrThreshold>

Related Commands

cnfalm, dspalmcnt

Cards on Which This Command Executes

AUSM, FRSM, CESM

Attributes

Log: Yes State: Active Privilege: 3

System Response

No system response unless an error occurs.

xcnfchan

This command configures the extended parameters for a channel.

Full Name

Configure Extended Channel Parameters

Syntax

xcnfchan -chn <ChanNum> -en <ChanStatus> [ -cbrserv <CBRService> -clkmode <MODE> -cdv <CDV> -clip <CLIP> -maxbuf <MAX BUF SIZE> ]

Related Commands

cnfchan, delchan, xdspchan, dspchan

Cards on Which This Command Executes

CESM

Attributes

Log: Yes State: Active Privilege: 2

System Response

No system response unless an error occurs.

xcnfif

The xcnfif command modifies parameters for an existing broadband interface on a PXM. System software does not allow you to conflict with existing configurations. You may need to reduce the bandwidth allocation or VPI/VCI range on one or more interfaces before you expand the resources for a interface. Refer to the upif command description for more information on resource partitioning.

Full Name

Configure a Broadband Interface

Syntax
xcnfif -if <bbIfNum> -bl <lineNum> -ie <rowStatus> -ib <ingrPctBw> -eb <egrPctBw> -iv <minVpi> -av <maxVpi>

where:

<bbIfNum>

is the number of the logical interface. Number between 1 and 32

<lineNum>

is the number of the line to tie the logical interface to. Number between 1 and 4

<rowStatus>

Number between 1-3, 1 for enable, 2 for disable, 3 for modify

<ingrPctBw

is the percent of the line ingress queue bandwidth for the logical interface. Number between 0 and 100

<egrPctBw>

is the percent of the line egress queue bandwidth for the logical interface. Number between 0 and 100

<minVpi>

is the minimum VPI value. Number between 0 and 4095

<maxVpi>

is the maximum VPI value. Number between 0 and 4095

Related Commands

upif

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
wilco.1.7.PXM.a > xcnfif -if 1 -bl 4 -ie 1 -ib 10 -eb 10 -iv 0 -av 19
Description

Configure and enable broadband interface number 1 on line 4 to use 10% of the line bandwidth for both ingress and egress, have a minimum virtual path interface (VPI) of 0, and a maximum virtual path interface (VPI) of 19.

System Response

none

Enter the dspif command to confirm.

wilco.1.7.PXM.a > dspif

 
 ifNum  Status  Line  ingrPctBw egrPctBw minVpi maxVpi
------------------------------------------------------
  1     Ena       1       10       10        0     19

xcnfifip

This command configures the IP address for the LAN, Slip and ATM interfaces.

Syntax:

xcnfifip -ifn <Interface> -ipa <ip_addr> -msk <NetMask> -bc <Brocast addr> -ipo <Oper>

where:

<Interface>

Interface = 26. 28, 37, where:
26 for Ethernet,
28 for Slip,
37 for ATM

<ip_addr>

IP address -- nnn.nnn.nnn.nnn, n = 0-9, nnn < 256

<NetMask>

NetMask = nnn.nnn.nnn.nnn, n = 0-9, nnn < 256

<Brocast Addr>

Broadcast Address = nnnnnnnn, n is hexadecimal, ethernet only

<Oper>

enable/disable IP Address: 1 = Add, 2 = Delete

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Any Privilege: SuperUser

Example
spirit4.1.7.PXM.a > xcnfifip -if 26 -ipa 172.29.37.40 -msk 255.255.255.000 -bc 255.255.255.000 -ipo 1
Description

Configure and enable the Ethernet interface to use the IP address 172.29.37.40, the netmask 255.255.255.000, and the broadcast address 255.255.255.000.

System Response

none

Enter the dspifip command to confirm.

spirit4.1.7.PXM.a > dspifip

   Interface     IPAddress             NetMask       BroadcastAddress
  ------------  -----------------  ----------------- -----------------
   Ethernet     172.29.37.40        255.255.255.000  255.255.255.000
   Slip         192.169.3.18        255.255.255.000
   ATM                              255.255.255.000
 
spirit4.1.7.PXM.a >

xcnfilmi

This command configures a port's local management interface. No messages appear on screen unless an error occurs.

Full Name

Configure ILMI

Syntax

xcnfilmi -pti <port_num> -s <signal_type> -vpi <virtual_path_identifier> -vci <virtual_channel_identifier> -t <trap_enable> -mti <min_trap_int> -kap <keep_alive> -eth <ErrorThreshold> -evh <EventThreshold> -pi <PollingInterval> -mei <MinimumEnquiryInterval> -ar <AddrRegEnable>

where:

<port_num>

port number in the range 1-8

<signal_type>

signalling type: 1 = other, 2 = no signalling, and 3 = ILMI

<virtual_path_id>

virtual path identifier in the range 1-255

<virtual_channel_id>

virtual channel identifier in the range 1-65535

<trap_enable>

ILMI trap enable: 1 = disable, 2 = enable

<min_trap_int>

minimum trap interval in the range 1-10 seconds.

<keep_alive>

enable for Keep Alive Polling: 1 = disable, 2 = enable

<ErrorThreshold>

Error Threshold in the range 1-10 seconds.

<EventThreshold>

Event Threshold in the range 1-10 seconds.

<PollingInterval>

Polling interval in the range 5-60 seconds.

<MinimumEnquiryInterval>

minimum enquiry interval in the range 1-20 seconds.

<AddrRegEnable>

enable for Address Registration: 1 = disable, 2 = enable

Related Commands

xdspilmi, dspilmi, dspilmicnt

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1

System Response

No system response unless an error occurs.

xcnfln

This command configures a line on the current card to be either T1 or E1. If the command line does not include the E1 signalling parameter, the line is a T1.

Full Name

Configure Line

Syntax

xcnfln <line_num> <line_code> <line_len> <clk_src> [E1-signalling]

where:

<line_num>

values in the range 1-8

<line_code>

line coding: 2 for B8ZS, 3 for HDB3, 4 for AMI

<line_len>

line length: 1-7 for T1, 8-9 for E1

<clk_src>

clock source: 1 for loop clock; 2 for local clock

[E1-signalling]

CAS: CAS, no CRC
CAS_CRC: CAS with CRC
CCS: CCS no CRC
CCS_CRC: CCS with CRC
CLEAR: Clear E1

Related Commands

cnfln, addln, delln

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: Yes State: Active Privilege: 1

Example

xcnfln 4 2 1 1

Description

Configure line 4 to be T1 with B8ZS line coding, have a length of 1, and use the loop clock as a clock source.

System Response

No system response unless an error occurs.

xcnfport

This command configures a service port on an FRSM or an AUSM.

The screen does not display a message after successful command entry. The configuration can be verified using the xdspport or dspport command.

The syntax for this command differs according to the service module being addressed.

Summary for FRSM

Full Name

Configure Port

Syntax

xcnfport <port_num> <lmi_sig> <asyn> <T391> <T392> <N391> <N392> <N393> <CLLMEN> <CLLMTM>

where:

port_num

port number is in the range of values 1-192 for FRSM T1, 1-248 for FRSM E1

lmi_sig

LMI signalling: 1 = Other, 2 = None, 3 = StrataLMI,
4 = AnnexAUNI, 5 = AnnexDUNI, 6 = AnnexANNI,
7 = AnnexDNNI

asyn

asyn update is (y)es or (n)o

T391

T391 timer is in the range 5-30 sec.

T392

T392 timer is in the range 5-30 sec.

N391

N391 counter is in the range 1-255

N392

N392 counter is in the range 1-10

N393

N393 counter is in the range 1-10

CLLMEN

CLLM Enable is either 1 = Disable or 2 = Enable

CLLMTM

CLLM Timer is in the range 40-5000 ms

Possible errors are:

Related Commands

xcnfport, addport, delport, dspport, dspports, xdspport, xdspports

Cards on Which This Command Executes

FRSM

Attributes

Log: Yes State: Active Privilege: 1-6

Summary for AUSM

Full Name

Configure Port

Syntax

xcnfport <port_num> <plpp loopback>

where:

port_num

range of values 1-8

plpp loopback

1 = no loopback, 2 = remote loopback, 3 = local loopback

Related Commands

cnfport, addport, delport, dspport, dspports, xdspport, xdspports

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1

System Response

No system response unless an error occurs.

xcnfportq

This command configures a port's queue parameters on the current AUSM. No messages appear on screen unless an error occurs.

Full Name

Configure Port Queue

Syntax
xcnfportq -pt <port_num> -pqn <q_num> -e <Enable> -qa <q_algo> -sn <service_seq> -qdm <q_depth> -clph <clp_high> -clpl <clp_low> -clpt <efci_thres> -mxbi <EgressMaxBandwidthInc> -mibi <MinimumBandwidthInc>

where:

port_num

port_num is a port number in the range 1-8

q_num

queue number is the queue number in the range 1-16

q_algo

queue algorithm is the queue algorithm in the range 1-5, 0 = disable queue

service_seq

service sequence is the service sequence number in the range 1-16

q_depth

queue depth is the maximum queue depth in the range 1-16000 cells

clp_high

CLP Threshold High: 1-16000 Cells

Once the High Cell Loss Priority threshold is exceeded cells can have a CLP bit set, making them discard eligible.

clp_low

CLP Threshold Low: 1-16000 Cells

The Low Cell Loss Priority threshold

Once the low Cell Loss Priority threshold is passed cells will no longer have the CLP bit set, making them discard eligible.

efci_thres

EFCI Threshold:

An Explicit Forward Congestion Indicator is sent to the sending node when the threshold is exceeded.

1-16000 Cells

EgressMaxBandwidthInc

Egress Maximum Bandwidth Increment:

An Explicit Forward Congestion Indicator is sent to the sending node when the threshold is exceeded.

0-4096 Cells

MinimumBandwidthInc

Minimum Bandwidth Increment:

An Explicit Forward Congestion Indicator is sent to the sending node when the threshold is exceeded.

0-4096 Cells

Related Commands

cnfportq, xcnfportqs

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-6

Example
spirit3.1.22.AUSM8.a > xcnfportq -pt 1

System Response

No system response unless an error occurs.


xcnfred

The xcnfred command links two MGX 8850 slots (a primary slot and a secondary slot) so that the switch treats the cards in these slots as a redundant pair of cards. The secondary slot should be in the same half of the shelf (upper or lower) as the primary slot. Redundancy can be 1:1 or 1:N. If the redundancy is 1:N, you must link one secondary slot to N primary slots through multiple executions of this command.

Full Name

Configure Redundancy

Syntax

xcnfred -pri <redPrimarySlotNum> -en <rowStatus> -ser <redSecondarySlotNum> -type <RedType>

where:

redPrimarySlotNum

is slot number of the slot containing the primary card of the card pair. The range is 1-6, 9-14, 17-22, and 25-30.

<rowStatus>

number between 1 - 3 (1:enable 2:disable 3: modify)

redSecondarySlotNum

is slot number of the slot containing the secondary card of the card pair. The range is 1-6, 9-14, 17-22, and 25-30.

RedType

is type of redundancy, where 1 = 1:1, and 2 = 1:N.

Related Commands

dspred, delred

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Active Privilege: Any

Example
node501.1.7.PXM.a > xcnfred -pri 1 -en 1 -ser 4 -type 1
Description

Add 1:1 redundancy between the card in slot 4 and the card in slot 1.

System Response

none

xcnfrscprtn

This command configures parameters for resource partitions.

Full Name

Configure Resource Partition Extended Parameters

Syntax
xcnfrscprtn -pn <bbIfNum> -cn <ctrlrNum> -pr <rowStatus> -ps <inUse> -pi <ingrPctBw> -pe <egrPctBw> -pi <minVpi> -pu <maxVpi> -pc <minVci> -pd <maxVci> -pth <maxGLCNs>

where:

<bbIfNum>

a number between 1 and 32

<ctrlrNum>

number between 1 and 3 (1:PAR, 2:PNNI, 3:TAG)

<rowStatus>

number between 1 - 3 (1:enable 2:disable 3: modify)

<inUse>

a number between 1 and 2 (1:In Use, 2: Not In Use)

<ingrPctBw>

a number between 0 and 100

<egrPctBw>

a number between 0 and 100

<minVpi>

a number between 0 and 4095

<maxVpi>

a number >= bbIfRscPrtVpiLow and <= 4095

<minVci>

a number between 0 and 65535

<maxVci>

a number between 0 and 65535

<maxGLCNs>

a number between 0 and 32767

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Any Privilege: Cisco

Example
 spirit4.1.7.PXM.a > xcnfrscprtn  -pn 1 -cn 1 -pr 1 -ps 1 -pi 100 -pe 100 -pi 0 -pu 4095 -pc 0 -pd 65535 - pth 32767 
 
Description

Configure and enable a resource partition.

System Response

none

xcnfsrmlink

The xcnfsrmlink command configures and enables a link between a T1 line within a T3 line on a SRM-3T3 card and a slot and line number on a T1 service module.

Full Name

Configure Link

Syntax

xcnfsrmlink -srmt3 <T3 line number> -srmt1 <T1 line number> -en <rowStatus> -srms1 <Target Slot number> -srmln <Slot line number>

where:

T3 line number

SRM-3T3 T3 line number in the format slot.line where slot can be either 15 or 31, and the port range is 1-3. Slot number 15 is used for the cards in slot and 15 and 16, whichever is active and slot 31 is used for cards in 31 and 32.

T1 line number

start T1 line number within the T3 line (range 1-28)

<rowStatus>

number between 1 - 3 (1:enable 2:disable 3: modify)

Target Slot number

T1 service module slot number to be linked, where Target Slot number = 1-6|9-14|17-22|25-30

Slot line number

T1 line number in the slot to be linked (range 1-4 or 1-8) depending upon the ports in the service module

Related Commands

addlink, dsplink, dellink, xdspsrmlink

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example
 spirit4.1.7.PXM.a > xcnfsrmlink -srmt3 15.2 -srmt1 1 -en 1 -srmsl 3 -srmln 5 
Description

Configure and enable a link between the T1 line 1 within T3 line 2 on the SRM-3T3 card in slot 15 and T1 line number 5 on the T1 service module in slot 3.

System Response

none


xcnftrapmgr

This command enables or disables the trap manager function. If enabled, this command configures the port number and IP address of the trap manager that is to receive traps.

Syntax

xcnftrapmgr -ip <ip_addr> -pt <portNum> -en <enabled> -tf <Trap Flag> -seq <SeqNum>

where:

<ip_addr>

IP address -- nnn.nnn.nnn.nnn, n = 0-9, nnn < 256

<portNum>

The port the trap manager uses to receive traps. The default is 162.

<enabled>

Number between 1-3, where 1: Add 2: Delete 3: Modify

<Trap Flag>

Number between 1-2, 1:Off 2: On

<SeqNum>

Sequence Number

Related Commands

None

Cards on Which This Command Executes

PXM

Attributes

Log: Yes State: Active Privilege: SuperUser

Example

cnftrapmgr -ip 192.169.3.102 -pt 125 -en 1 -tf 1 -seq 00

System Response

none


xdelcon

This command deletes a connection on an AUSM.

No messages appear on screen after command entry unless the command cannot execute as entered.

Full Name

Delete a Connection

Syntax

xdelcon <connection number>

where:

connection number

connection number is in the range 16-1015

Related Commands

delcon, xdspcon, dspcon, xdspcons, dspcons, xaddcon, addcon

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1-2

System Response

No system response unless an error occurs.

xdnport

The xdnport command downs a port. No messages appear on screen unless an error occurs.

Full Name

Down Port

Syntax

dnport <PortNum>

where:

PortNum

Port Number = 1-8

Related Commands

upport

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Active Privilege: 1

System Response

No system response unless an error occurs.

xdspchan

Displays a channel on the current card.

Full Name

Display Channel

Syntax

xdspchan <channel number>

where:

channel number

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For AUSM, 16-1015

· For CESM-8T1/E1, 32-279

· For CESM-T3/E3, one connection starting at 32

Related Commands

xdspchans, dspchans, xcnfchan, cnfchan

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: 1-6

Example 1
spirit3.1.20.FRSM.a > xdspchan 22
Description

Display the channel characteristics of channel 22 on the FRSM card in slot 20.

System Response
  ChanNum:                  22
  ChanRowStatus:            Add
  ChanPortNum:              1
  ChanDLCI:                 1000
  EgressQSelect:            2
  IngressQDepth:            65535
  IngressQDEThresh:         32767
  IngressQECNThresh:        6553
  EgressQDepth:             65535
  EgressQDEThresh:          32767
  EgressQECNThresh:         6553
  DETaggingEnable:          Disabled
  CIR:                      9600
  Bc:                       5100
  Be:                       5100
  IBS:                      100
  ForeSightEnable:          Disabled
  QIR:                      25
  MIR:                      25
  PIR:                      25
  ChanLocalRemoteLpbkState: Disabled
  ChanTestType:             TestOff
  ChanTestState:            NotInProgress
  ChanRTDresult:            65535 ms
  ChanType:                 SIW-Xlat
  ChanFECNmap:              setEFCIzero
  ChanDEtoCLPmap:           mapCLP
  ChanCLPtoDEmap:           mapDE
  ChanFrConnType:           PVC
  ChanIngrPercentUtil:      100
  ChanEgrPercentUtil:       100
  ChanEgrSrvRate:           9600
  ChanOvrSubOvrRide:        Enabled
  ChanLocalVpi:             0
  ChanLocalVci:             1000
  ChanLocalNSAP:            504f504559453300000000000000000014000100
  ChanRemoteVpi:            0
  ChanRemoteVci:            0
  ChanRemoteNSAP:           NULL NSAP
  ChanMastership:           Slave
  ChanVpcFlag:              Vcc
  ChanConnServiceType:      ATFR
  ChanRoutingPriority:      1
  ChanMaxCost:              255
  ChanRestrictTrunkType:    No Restriction
  ChanConnPCR:              25
  ChanConnMCR:              25
  ChanConnPercentUti:       100
  ChanNum:                  42
  ChanRowStatus:            Mod
  ChanPortNum:              20
  ChanDLCI:                 300
  EgressQSelect:            2
 
Type <CR> to continue, Q<CR> to stop:
 
  IngressQDepth:            65535
  IngressQDEThresh:         32767
  IngressQECNThresh:        6553
  EgressQDepth:             65535
  EgressQDEThresh:          32767
  EgressQECNThresh:         6553
  DETaggingEnable:          Disabled
  CIR:                      9600
  Bc:                       5100
  Be:                       5100
  IBS:                      100
  ForeSightEnable:          Disabled
  QIR:                      25
  MIR:                      25
  PIR:                      25
  ChanLocalRemoteLpbkState: Disabled
  ChanTestType:             TestOff
  ChanTestState:            NotInProgress
  ChanRTDresult:            65535 ms
  ChanType:                 NIW
  ChanFECNmap:              setEFCIzero
  ChanDEtoCLPmap:           mapCLP
  ChanCLPtoDEmap:           mapDE
  ChanFrConnType:           PVC
  ChanIngrPercentUtil:      100
  ChanEgrPercentUtil:       100
  ChanEgrSrvRate:           9600
  ChanOvrSubOvrRide:        Enabled
  ChanLocalVpi:             0
  ChanLocalVci:             300
  ChanLocalNSAP:            504f504559453300000000000000000014001400
  ChanRemoteVpi:            17
  ChanRemoteVci:            18
  ChanRemoteNSAP:           504f504559453300000000000000000000000100
  ChanMastership:           Master
  ChanVpcFlag:              Vcc
  ChanConnServiceType:      ATFR
  ChanRoutingPriority:      1
  ChanMaxCost:              255
  ChanRestrictTrunkType:    No Restriction
  ChanConnPCR:              25
  ChanConnMCR:              25
  ChanConnPercentUti:       100
 
  ChanNumNextAvailable:  25
 
spirit3.1.20.FRSM.a >
Example 2
spirit3.1.21.CESM.a > xdspchan 33
Description

Display the channel characteristics of channel 33 on the CESM card in slot 22.

System Response
 
  ChanNum:                  33
  ChanRowStatus:            Add
  ChanLineNum:              1
  ChanMapVpi:               5
  ChanMapVci:               33
  ChanCBRService:           structured
  ChanClockMode:            Synchronous
  ChanCAS:                  Basic
  ChanPartialFill:          47
  ChanMaxBufSize:           124 bytes
  ChanCDVT:                  1000 micro seconds
  C L I P:                  2500 milliseconds
  ChanLocalRemoteLpbkState: Disabled
  ChanTestType:             TestOff
  ChanTestState:            NotInProgress
  ChanRTDresult:            65535 ms
  ChanPortNum               2
  ChanConnType              PVC
  ISDetType                 DetectionDisabled
  CondData                  255
  CondSignalling            0
  ExtISTrig                 DisableIdleSupression
  ISIntgnPeriod             4095 seconds
  ISSignallingCode          0
  OnHookCode                1
  ChanLocalVpi:             0
  ChanLocalVci:             0
  ChanLocalNSAP:            504f504559453300000000000000000015000200
  ChanRemoteVpi:            0
  ChanRemoteVci:            0
  ChanRemoteNSAP:           NULL NSAP
  ChanMastership:           Slave
  ChanVpcFlag:              Vcc
  ChanConnServiceType:      CBR
  ChanRoutingPriority:      1
  ChanMaxCost:              255
  ChanRestrictTrunkType:    No Restriction
  ChanConnPCR:              688
  ChanConnMCR:              688
  ChanConnPercentUtil:      100
  ChanNum:                  41
  ChanRowStatus:            Mod
  ChanLineNum:              3
  ChanMapVpi:               5
  ChanMapVci:               41
  ChanCBRService:           unstructured
  ChanClockMode:            Synchronous
  ChanCAS:                  Basic
  ChanPartialFill:          47
  ChanMaxBufSize:           7680 bytes
  ChanCDVT:                  20000 micro seconds
  C L I P:                  30000 milliseconds
  ChanLocalRemoteLpbkState: Disabled
  ChanTestType:             TestOff
  ChanTestState:            Failed
  ChanRTDresult:            65535 ms
  ChanPortNum               10
  ChanConnType              PVC
  ISDetType                 DetectionDisabled
  CondData                  255
  CondSignalling            8
 
Type <CR> to continue, Q<CR> to stop:
 
  ExtISTrig                 DisableIdleSupression
  ISIntgnPeriod             4095 seconds
  ISSignallingCode          0
  OnHookCode                1
  ChanLocalVpi:             0
  ChanLocalVci:             0
  ChanLocalNSAP:            504f504559453300000000000000000015000a00
  ChanRemoteVpi:            11
  ChanRemoteVci:            111
  ChanRemoteNSAP:           504f504559453300000000000000000000000100
  ChanMastership:           Master
  ChanVpcFlag:              Vcc
  ChanConnServiceType:      CBR
  ChanRoutingPriority:      1
  ChanMaxCost:              255
  ChanRestrictTrunkType:    No Restriction
  ChanConnPCR:              4107
  ChanConnMCR:              4107
  ChanConnPercentUtil:      100
 
  ChanNumNextAvailable:  49
 
spirit3.1.21.CESM.a >

xdspchancnt

This command displays the counter contents of all channels (or the specified channel with the optional -chn parameter)..

Full Name

Display Channel Count

Syntax

xdspchancnt [ -chn <channel number>]

where:

channel number

A number in the range:

· For FRSM-8T1/E1, 16-1015

· For FRSM-T3/E3/HS2, 16-2015

· For FRSM-2CT3, 16-4015

· For PXM, 16-4111

· For AUSM, 16-1015

· For CESM-8T1/E1, 32-279

· For CESM-T3/E3, one connection starting at 32

Related Commands

dspchancnt, xdspchstats, dspchstats

Cards on Which This Command Executes

FRSM, AUSM, PXM, CESM

Attributes

Log: No State: Any Privilege: 1-6

Example 1
spirit3.1.20.FRSM.a > xdspchancnt -chn 22
Description

Display the channel counters of all the channels on the FRSM card in slot 20.

System Response
  ChanNum:                   22
  ChanState:                 okay
  ChanUpTime:                1634994
 
                                    Tx                    Rx
                             ---------------       ---------------
  AbitState:                 Sending A=1           Off
  ATMState:                  Not sending any state Not receiving any state
  Total Frames:              64187                 57994
  Total Bytes:               3410008               3317254
  Frames DE:                 0                     0
  Bytes DE:                  0                     0
  Frames Discarded:          2                     7079
  Bytes Discarded:           118                   410582
  FramesDiscXceedQDepth:     0                     0
  BytesDiscXceedQDepth:      0                     0
  FramesDiscXceedDEThresh:   0                     0
  Frames FECN:               0                     0
  Frames BECN:               0                     0
  FramesTagged FECN:         0                     0
  FramesTagged BECN:         0                     0
  KbpsAIR:                   0                     0
 
Type <CR> to continue, Q<CR> to stop:
 
                                   Tx                    Rx
                             ---------------       ---------------
  FramesTaggedDE:            0                     0
  BytesTaggedDE:             0                     0
  RcvFramesDiscShelfAlarm:                         0
  XmtFramesDiscPhyLayerFail: 0
  XmtFramesDiscCRCError:     0
  XmtFramesDiscReAssmFail:   0
  XmtFramesDiscSrcAbort:     0
  XmtFramesDuringLMIAlarm:   14
  XmtBytesDuringLMIAlarm:    794
  RcvFramesDiscUPC:                                0
  XmtFramesInvalidCPIs:      0
  XmtFramesLengthViolations: 0
  XmtFramesOversizedSDUs:    0
  XmtFramesUnknownProtocols: 0
  RcvFramesUnknownProtocols:                       7079
 
Type <CR> to continue, Q<CR> to stop:
 
  ChanNum:                   42
  ChanState:                 alarm
  ChanUpTime:                4
 
                                    Tx                    Rx
                             ---------------       ---------------
  AbitState:                 Sending A=0           Off
  ATMState:                  Sending AIS OAM state Receiving AIS OAM
  Total Frames:              0                     0
  Total Bytes:               0                     0
  Frames DE:                 0                     0
  Bytes DE:                  0                     0
  Frames Discarded:          0                     0
  Bytes Discarded:           0                     0
  FramesDiscXceedQDepth:     0                     0
  BytesDiscXceedQDepth:      0                     0
  FramesDiscXceedDEThresh:   0                     0
  Frames FECN:               0                     0
  Frames BECN:               0                     0
  FramesTagged FECN:         0                     0
  FramesTagged BECN:         0                     0
  KbpsAIR:                   0                     0
 
Type <CR> to continue, Q<CR> to stop:
 
                                   Tx                    Rx
                             ---------------       ---------------
  FramesTaggedDE:            0                     0
  BytesTaggedDE:             0                     0
  RcvFramesDiscShelfAlarm:                         0
  XmtFramesDiscPhyLayerFail: 0
  XmtFramesDiscCRCError:     0
  XmtFramesDiscReAssmFail:   0
  XmtFramesDiscSrcAbort:     0
  XmtFramesDuringLMIAlarm:   0
  XmtBytesDuringLMIAlarm:    0
  RcvFramesDiscUPC:                                0
  XmtFramesInvalidCPIs:      0
  XmtFramesLengthViolations: 0
  XmtFramesOversizedSDUs:    0
  XmtFramesUnknownProtocols: 0
  RcvFramesUnknownProtocols:                       0
Example 2
spirit4.1.7.PXM.a > xdspchancnt -cnt 17
Description

Display the channel counters of channel 17 on the PXM card in slot 7.

System Response
Channel Number               :         17
Channel State                :      alarm
Channel Ingress State        :      alarm
Channel Egress State         :      other
CLP=0  Rcvd. Cells           :          0
CLP=1  Rcvd. Cells           :          0
GCRA1  Non Conforming Cells  :          0
GCRA2  Non Conforming Cells  :          0
EOF    Cells Rcvd.           :          0
CLP=0  Discard Cells         :          0
CLP=1  Discard Cells         :          0
Total  Xmtd. Cells           :       2125
CLP=0  Xmtd. Cells           :          0
CLP=1  Xmtd. Cells           :       3203
CLP=0  Discard Cells to Port :          0
CLP=1  Discard Cells to Port :          0
 
spirit4.1.7.PXM.a > 
 
Example 3
spirit3.1.21.CESM.a > xdspchancnt
Description

Display the channel counters of all the channels on the CESM card in slot 21.

System Response
 
ChanNum:                   33
Chan State:                alarm
Chan RCV ATM State:        Normal
Chan XMT ATM State:        Sending AIS OAM
Cell Loss Status:          No Cell Loss
Reassembled Cells:         0
Generated Cells:           1234508943
Header Errors:             0
Seqence Mismatches :       0
Lost Cells:                0
Channel Uptime (secs.)     1808376
Signalling Status          Offhook
 
Type <CR> to continue, Q<CR> to stop:
 
ChanNum:                   41
Chan State:                alarm
Chan RCV ATM State:        Normal
Chan XMT ATM State:        Sending AIS OAM
Cell Loss Status:          Cell Loss
Reassembled Cells:         0
Generated Cells:           317857344
Header Errors:             0
Seqence Mismatches :       0
Lost Cells:                0
Channel Uptime (secs.)     77406
Signalling Status          Offhook
 
 
spirit3.1.21.CESM.a >
Example 4
spirit3.1.21.CESM.a > xdspchancnt -chn 33
Description

Display the channel counters of channel 33 on the CESM card in slot 21.

System Response
 
ChanNum:                   33
Chan State:                alarm
Chan RCV ATM State:        Normal
Chan XMT ATM State:        Sending AIS OAM
Cell Loss Status:          No Cell Loss
Reassembled Cells:         0
Generated Cells:           1234551200
Header Errors:             0
Seqence Mismatches :       0
Lost Cells:                0
Channel Uptime (secs.)     1808438
Signalling Status          Offhook
 
 
spirit3.1.21.CESM.a >
 
Example 5
spirit3.1.20.FRSM.a > xdspchancnt -chn 22
Description

Display the channel counters of channel 22 on the FRSM card in slot 20.

System Response
 
 
  ChanNum:                   22
  ChanState:                 okay
  ChanUpTime:                1635192
 
                                    Tx                    Rx
                             ---------------       ---------------
  AbitState:                 Sending A=1           Off
  ATMState:                  Not sending any state Not receiving any state
  Total Frames:              64187                 58001
  Total Bytes:               3410008               3317660
  Frames DE:                 0                     0
  Bytes DE:                  0                     0
  Frames Discarded:          2                     7079
  Bytes Discarded:           118                   410582
  FramesDiscXceedQDepth:     0                     0
  BytesDiscXceedQDepth:      0                     0
  FramesDiscXceedDEThresh:   0                     0
  Frames FECN:               0                     0
  Frames BECN:               0                     0
  FramesTagged FECN:         0                     0
  FramesTagged BECN:         0                     0
  KbpsAIR:                   0                     0
 
Type <CR> to continue, Q<CR> to stop:
 
                                   Tx                    Rx
                             ---------------       ---------------
  FramesTaggedDE:            0                     0
  BytesTaggedDE:             0                     0
  RcvFramesDiscShelfAlarm:                         0
  XmtFramesDiscPhyLayerFail: 0
  XmtFramesDiscCRCError:     0
  XmtFramesDiscReAssmFail:   0
  XmtFramesDiscSrcAbort:     0
  XmtFramesDuringLMIAlarm:   14
  XmtBytesDuringLMIAlarm:    794
  RcvFramesDiscUPC:                                0
  XmtFramesInvalidCPIs:      0
  XmtFramesLengthViolations: 0
  XmtFramesOversizedSDUs:    0
  XmtFramesUnknownProtocols: 0
  RcvFramesUnknownProtocols:                       7079
 
 
spirit3.1.20.FRSM.a >

xdspchans

This command displays all the current channels on the card.

Full Name

Display Channels

Syntax

xdspchans

Related Commands

xdspchan, dspchan, addchan, delchan

Cards on Which This Command Executes

PXM, FRSM, CESM

Attributes

Log: No State: Any Privilege: 1-6

Example 1
spirit3.1.20.FRSM.a > xdspchans
Description

Display the channels on the current FRSM.

System Response
 
 
      DLCI      Chan EQ  I/EQDepth  I/EQDEThre  I/EECNThre  Fst/ DE Type  Alarm
  ------------- ---- -- ----- ----- ----- ----- ----- ----- --- --- ----- -----
  20.1.1.1000   22   2  65535/65535 32767/32767  6553/6553  Dis/Dis SIW-X  No
  20.8.20.300   42   2  65535/65535 32767/32767  6553/6553  Dis/Dis NIW    Yes
 
  Number of channels:    2
 
  ChanNumNextAvailable:  26
 
spirit3.1.20.FRSM.a >
Example 2
spirit3.1.21.CESM.a > xdspchans
Description

Display the channels on the current CESM.

System Response
 
    Channel     ChanNum   Status   CDVT   MaxBufSize   CLIP    CBRservice
  ------------  -------   ------  -----  ----------  ------  ------------
  21.1.2.33       33       Add     1000      124      2500   structured
  21.3.10.41      41       Mod    20000     7680     30000   unstructured
 
  Number of channels:    2
 
  ChanNumNextAvailable:  47
 
Example 3
spirit4.1.7.PXM.a > xdspchans
Description

Display the channels on the current PXM.

System Response
 
 
 
Chan Stat Intf locVpi locVci conTyp srvTyp PCR[0+1] Mst rmtVpi rmtVci State
----------------------------------------------------------------------------
  17 ADD    2     39      45  VCC    VBR     353208 Slv     0       0  alarm
 
spirit4.1.7.PXM.a >

xdspcon

Displays configuration data for a connection.

Full Name

Display Connection

Syntax

xdspcon -chn <channel number>

where:

channel number

channel number is in the range 16-1015

Related Commands

dspcon, xaddcon, addcon, xdelcon, delcon, xdspcons, dspcons

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Any Privilege: 1-6

Example
spirit3.1.22.AUSM8.a > xdspcon -chn 16
Description

Display the connection parameters for channel 16.

System Response
 
  ChanNum:                           16
  RowStatus:                         Del
  ConnectionType:                    VCC
  ServiceType:                       CBR
  PortNum:                           1
  VPI:                               0
  VCI (For VCC):                     0
  Local VPId(for VPC):               0
  EgressQNum:                        0
  IngressQDepth(cells):              1000
  IngressDiscardOption:              CLP hysterisis
  IngressFrameDiscardThreshold       1000
  IngressQCLPHigh(cells):            900
  IngressQCLPLow(cells):             800
  QCLPState:                         LOW
  IngressEfciThreshold(cells):       1000
 
  UPCEnable:                         Enabled
  PeakCellRate[0+1](cells/sec):      50
  CellDelayVariation[0+1]:           10000 (micro secs)
  PeakCellRate[0](cells/sec):        50
  CellDelayVariation[0]:             10000 (micro secs)
  SustainedCellRate(cells/sec):      50
 
Type <CR> to continue, Q<CR> to stop:
 
  MaximumBurstSize(cells):           1000
  SCRPolicing:                       CLP[0]
  CLPTagEnable:                      Enabled
  FrameGCRAEnable:                   Disable
 
  ForesightEnable:                   Disable
  InitialBurstSize(cells):           0
  ForeSightPeakCellRate(cells/sec):  50
  MinimumCellRate(cells/sec):        0
  InitialCellRate(cells/sec):        1
 
  LocalRemoteLpbkState:              Disable
  ChanTestType:                      No Test
  ChanTestState:                     Not In Progress
  ChanRTDresult:                     65535 ms
 
  Ingress percentage util:           100
  Egress percentage util :           100
  Egress Service Rate:               50
  LocalVpi:                          0
  LocalVci:                          0
 
Type <CR> to continue, Q<CR> to stop:
 
  LocalNSAP:                         5468697320697320612064756d6d79204e534150
  RemoteVpi:                         0
  RemoteVci:                         0
  RemoteNSAP:                        5468697320697320612064756d6d79204e534150
  Mastership:                        Slave
  VpcFlag:                           Vcc
  ConnServiceType:                   CBR
  RoutingPriority:                   1
  MaxCost:                           255
  RestrictTrunkType:                 No Restriction
  ConnPCR:                           50
  ConnMCR:                           0
  ConnPercentUtil:                   100
 
  ChanNumNextAvailable     :  16
  Local VpId NextAvailable :  4
 
spirit3.1.22.AUSM8.a >

xdspcons

This command displays details of all connections between the current AUSM and the card to which the current shelf is attached.

Full Name

Display Connections

Syntax

xdspcons

Related Commands

dspcons, xaddcon, addcon, xdelcon, delcon, xdspcon

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Any Privilege: 1-6

Example
spirit.1.19.AUSM8.a > xdspcons
Description

Display parameters for the connections on the current AUSM.

System Response
Chan    Port.VPI.VCI    ConnType    Service Type    PCRlot1   Q-Depth     State
30        1.10.100       VCC            ABR          3622      2000       Active
33        1.10.200       VPC            CBR          3622      100        Alarm
 

xdspilmi

This command displays the interim local management interface (ILMI) configuration.

Full Name

Display ILMI

Syntax

xdspilmi -pt <port_num>

where:

port_num

port_num is in the range 1-n, where n is the highest port number on the card.

Related Commands

cnfilmi, xcnfilmi, dspilmicnt

Cards on Which This Command Executes

PXM, AUSM

Attributes

Log: No State: Any Privilege: 1-6

Example 1
spirit.1.19.AUSM8.a > xdspilmi -pt 1
Description

Display the ILMI configuration for port 1.

System Response
  Port Num:                      1
  Signalling:                    No signalling
  SignallingVPI:                 0
  SignallingVCI:                 0
  ILMITrap:                      Disabled
  ILMI-Min-Trap-Interval (secs): 1
  KeepAlivePolling:              Disabled
  ErrorThreshold:                3
  EventThreshold:                4
  PollingInterval (secs):        30
  MinimumEnquiryInterval (secs): 10
  EXT Operation:                 port 2

xdspln

The xdspln command displays the detailed configuration for a specified line.

Full Name

Display Line Configuration

Syntax

On FRSM, CESM, or AUSM cards

xdspln -ds1 <line number>

where:

line number

line number range is 1-8 on 8-port service modules

or

xdspln <-rs232> <line number>

where:

line number

line number range is 1-2

Related Commands

addln, xcnfln, cnfln, delln

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Any state Privilege: 1-6

Example 1
spirit3.1.22.AUSM8.a > xdspln -ds1 2        
Description

Display line 2 on the current AUSM card.

System Response
  LineNum:                   2
  LineConnectorType:         RJ-48
  LineType:                  dsx1ESF
  LineEnable:                Disable
  LineCoding:                dsx1B8ZS
  LineLength:                0-131 ft
  LineXmtClockSource:        LocalTiming
  LineLoopbackCommand:       NoLoop
  LineSendCode:              NoCode
  LineUsedTimeslotsBitMap:   0xffffffff
  LineLoopbackCodeDetection: codeDetectDisabled
  LineBERTEnable:            Disable
 
  LineNumOfValidEntries: 8
Example 2
spirit.1.17.CESM.a > xdspln -ds1 8
 
Description

Display line 8 on the current CESM card.

System Response
  LineNum:                   8
  LineConnectorType:         SMB
  LineEnable:                Enabled
  LineType:                  dsx1E1CAS
  LineCoding:                dsx1HDB3
  LineLength:                G.703 75 ohm
  LineXmtClockSource:        LocalTiming
  LineLoopbackCommand:       NoLoop
  LineSendCode:              NoCode
  LineUsedTimeslotsBitMap:   0x0
  LineLoopbackCodeDetection: codeDetectDisabled
 
  LineNumOfValidEntries: 8
 
spirit.1.17.CESM.a >
 
Example 3
spirit.1.1.FRSM.a > xdspln -ds1 1
Description

Display line 1 on the current FRSM card.

System Response
  LineNum:                   1
  LineConnectorType:         RJ-48
  LineType:                  dsx1ESF
  LineEnable:                Disable
  LineCoding:                dsx1B8ZS
  LineLength:                0-131 ft
  LineXmtClockSource:        LocalTiming
  LineLoopbackCommand:       NoLoop
  LineSendCode:              NoCode
  LineUsedTimeslotsBitMap:   0x0
  LineLoopbackCodeDetection: codeDetectDisabled
  LineBertEnable:            Disable
 
  LineNumOfValidEntries: 8
 
spirit.1.1.FRSM.a >
 
Example 4
spirit3.1.21.CESM.a > xdspln -rs232 1
Description

Display the RS232 line 1 on the current CESM card.

System Response
 
  Port            Type          Enable   Baudrate
  ----  ----------------------  --------  --------
  21.1  Maintenance RS232 Port  Disable    19200
 
 SerialPortNumOfValidEntries: 1
 
spirit3.1.21.CESM.a >

xdsplns

This command displays the configuration parameters for all lines on the current card. The displayed parameters depend on the card.

Full Name

Display Lines

Syntax

xdsplns

Related Commands

dsplns, addln, xaddln, cnfln, xcnfln, xdelln, delln

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: 1-6

Example 1
spirit.1.1.FRSM.a > xdsplns -ds1
Description

Display ds1 lines on the current FRSM card.

System Response
  Line  Conn      Type     Status/Coding      Length     XmtClock Alarm Stats
        Type                                             Source         Alarm
  ----  ----- ------------ ------ -------- ------------- -------- ----- -----
  1.1   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  1.2   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  1.3   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  1.4   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  1.5   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  1.6   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  1.7   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
  1.8   RJ-48 dsx1ESF         Dis/dsx1B8ZS 0-131 ft      LocalTim
 
  LineNumOfValidEntries: 8
Example 2
spirit.1.1.FRSM.a > xdsplns -rs232
Description

Display RS-232 lines on the current FRSM card.

System Response
 
  Port            Type          Enable   Baudrate
  ----  ----------------------  --------  --------
  1.1   Maintenance RS232 Port  Disable    19200
 
 SerialPortNumOfValidEntries: 1
Example 3

spirit.1.7.PXM.a > xdsplns

Description

Display lines on the current PXM with a T3 trunk back card.

System Response
Line       Type        Coding      Length       Criteria   AIScBitsCheck
----  --------------  --------  -------------  ----------- -------------
2.1   dsx3CbitParity  dsx3B3ZS  LessThan450ft  3 out of 8  Check C-bits
 
LineNumOfValidEntries: 1
Example 4

spirit.1.7.PXM.a > xdsplns

Description

Display lines on the current PXM with a SONET 155 back card.

System Response
Medium   Medium   Medium    Medium 
Sonet     Line      Line      HSC      Payload      Frame      Time      Valid      Line      Line
Line      Type      Lpbk      mask     Scramble     Scramble Elapsed     Intvls     Coding    Type
----  --------------  --------  -------------  ----------- ------------------
 
 
LineNumOfValidEntries: 1
 
Example 5
spirit.1.17.CESM.a > xdsplns -ds1
Description

Display E1 lines on the current CESM.

System Response
 
  Line  Conn      Type     Status/Coding      Length     XmtClock Alarm Stats
        Type                                             Source         Alarm
  ----  ----- ------------ ------ -------- ------------- -------- ----- -----
  17.1  SMB   dsx1E1CAS       Ena/dsx1HDB3 G.703 75 ohm  LocalTim  Yes   No
  17.2  SMB   dsx1E1CAS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  17.3  SMB   dsx1E1CAS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  17.4  SMB   dsx1E1CAS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  17.5  SMB   dsx1E1CAS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  17.6  SMB   dsx1E1CAS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  17.7  SMB   dsx1E1CAS       Dis/dsx1HDB3 G.703 75 ohm  LocalTim
  17.8  SMB   dsx1E1CAS       Ena/dsx1HDB3 G.703 75 ohm  LocalTim  Yes   No
 
  LineNumOfValidEntries: 8
 
spirit.1.17.CESM.a >

xdspport

On an FRSM and CESM, the xdspport (or dspport) command displays the port configuration for the specified port. On an AUSM, the xdspport command displays the Physical Layer Protocol Processor of a port on the current AUSM.

Full Name

Display Port

Syntax

xdspport <port number>

where:

On an FRSM, port number is the port number in the range 1-192 for T1, 1-248 for E1

or

On an AUSM, port number is the port number in the range 1-8

or

On a CESM-8T1, port number is in the range 1 - 192

On a CESM-8E1, port number is in the range 1 - 248

On a CESM-T3E3, port number is always 1.

Related Commands

FRSM and CESM: addport, xcnfport, cnfport, delport

AUSM: xupport, upport, xdnport, dnport

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Active Privilege: 1-6

Example 1

spirit.1.17.FRSM.a > xdspport 1

Description

Display the port configuration for port 1 on the current FRSM.

System Response
  SlotNum:                      17
  PortLineNum:                  1
  PortNum:                      1
  PortRowStatus:                Add
  PortDs0Speed:                 64k
  PortDs0ConfigBitMap:          0xffffff
  PortEqueueServiceRatio:       1
  PortFlagsBetweenFrames:       1
  PortSpeed:                    1536kbps
  SignallingProtocolType:       NoSignalling
  AsynchronousUpdates:          Disable
  T391LineIntegrityTimer:       10
  T392PollingVerificationTimer: 15
  N391FullStatusPollingCounter: 6
  N392ErrorThreshold:           3
  N393MonitoredEventCount:      4
  PortState:                    FailedDuetoLineFailure
  PortSignallingState:          No Signalling Failure
  CLLMEnableStatus:             Disable
  CLLMxmtStatusTimer:           0
 
  PortDs0UsedLine1:             0x00ffffff
  PortDs0UsedLine2:             0x00ffffff
  PortDs0UsedLine3:             0x00ffffff
  PortDs0UsedLine4:             0x00ffffff
  PortNumNextAvailable:         60
Syntax : dspport "port_num"
         port number---values ranging from 1-192 are accepted
Example 2

spirit.1.20.AUSM.a > xdspport 1

Description

Display port 1 on the current AUSM.

  PortNumber:     1
  Cell Framing:   ATM
  Cell Scramble:  No Scramble
  Plpp Loopback:  No Loopback

xdspportcnt

This command displays counters for a specified port.

Full Name

Display Port Counters

Syntax

xdspportcnt <port number>

where:

port number

port number is in the range 1-192 for T1, 1-248 for E1 for FRSM, 1-8 for AUSM

Related Commands

cnfcd, dspcds

Cards on Which This Command Executes

FRSM, AUSM

Attributes

Log: No State: Any Privilege: 1-6

Example 1

spirit.1.20.AUSM.a > dspportcnt 1

Description

Display port counters on port 1 of the current AUSM.

System Response
 
  PortNum:                               1
  PortState:                             Sig. Failure
  IngressRcvCells:                       0
  IngressRcvCellRate (cells/sec):        0
  IngressRcvUtilization (percentage):    0
  IngressXmtCells:                       0
  IngressGFCErrorCells:                  0
  IngressVpiVciErrCells:                 0
  IngressUnknownVpiVci:                  0x0
  IngressRcvClpSetCells:                 0
  EgressRcvCells:                        0
  EgressRcvCellRate (cells/sec):         0
  EgressRcvUtilization (percentage):     0
  EgressXmtCells:                        0
  EgressXmtCellRate (cells/sec):         0
  EgressXmtUtilization (percentage):     0
  EgressPortAlarmDiscardCells:           0
  EgressXmtClpSetCells:                  0
  EgressXmtEfciSetCells:                 0
  PortXmtAisCells:                       0
  PortXmtSgmtLpbkCells:                  0
  PortRcvAisCells:                       0
  PortRcvFerfCells:                      0
  PortRcvSgmtLpbkCells:                  0
  PortRcvCrcErrOAMCells:                 0
  TotalIngressQFullDiscardCells:         0
  TotalIngressClpSetDiscardCells:        0
  TransmitFIFOFullCount (per card):      0
  ReceivedHECErrorCells:                 0
  HECErroredSeconds:                     0
  SeverelyHECErroredSeconds:             0
Example 2

spirit.1.17.FRSM.a > dspportcnt 1

Description

Display port counters on port 1 of the current FRSM.

System Response
  PortNum:                     1
 
                                    Tx                   Rx
                             ---------------       ---------------
  Total Frames:                233706                228459
  Total Bytes:                 6181533               5892272
  Frames FECN:                 0                     0
  Frames BECN:                 0                     0
  Frames Abort:                0                     2
  Buf Not Available:           0                     0
  KbpsAIR:                     0                     0
  XmtFramesDiscXceedQDepth:    0
  XmtBytesDiscXceedQDepth:     0
  XmtFramesDuringLMIAlarm:     17
  XmtByteDuringLMIAlarm:       791
  XmtFramesUnderrun:           0
  RcvFramesDE:                                       0
  RcvFramesDiscCRCError:                             0
  RcvFramesDiscIllegalHeader:                        0
  RcvFramesDiscAlignmentError:                       0
  RcvFramesDiscIllegalLen:                           0
  RcvFramesDiscXceedDEThresh:                        0
  RcvFramesDiscNoChan:                               0
  RcvFramesUnknownDLCI:                              2
  RcvLastUnknownDLCI:                                0
  RcvFramesTaggedFECN:                               0
  RcvFramesTaggedBECN:                               0
  RcvFramesTaggedDE:                                 0
  Status:                      169459                0
  StatusInquiry:               0                     169459
  AsynchUpdate:                0                     0
  RcvInvalidRequest:                                 0
  RcvUNISeqMismatch:                                 1
  RcvNNISeqMismatch:                                 0
  UNISignallingTimeout:                              3
  NNISignallingTimeout:                              0
  FramesCLLM:                  0                     0
  BytesCLLM:                   0                     0
  CLLMFailures:                                 0
 
Type <CR> to continue, Q<CR> to stop:
 
  PortNum:                     20
 
                                    Tx                   Rx
                             ---------------       ---------------
  Total Frames:                0                     0
  Total Bytes:                 0                     0
  Frames FECN:                 0                     0
  Frames BECN:                 0                     0
  Frames Abort:                0                     0
  Buf Not Available:           0                     0
  KbpsAIR:                     0                     0
  XmtFramesDiscXceedQDepth:    0
  XmtBytesDiscXceedQDepth:     0
  XmtFramesDuringLMIAlarm:     0
  XmtByteDuringLMIAlarm:       0
  XmtFramesUnderrun:           1
  RcvFramesDE:                                       0
  RcvFramesDiscCRCError:                             0
  RcvFramesDiscIllegalHeader:                        0
  RcvFramesDiscAlignmentError:                       0
  RcvFramesDiscIllegalLen:                           0
  RcvFramesDiscXceedDEThresh:                        0
  RcvFramesDiscNoChan:                               0
  RcvFramesUnknownDLCI:                              0
  RcvLastUnknownDLCI:                                0
  RcvFramesTaggedFECN:                               0
  RcvFramesTaggedBECN:                               0
  RcvFramesTaggedDE:                                 0
  Status:                      0                     0
  StatusInquiry:               0                     0
  AsynchUpdate:                0                     0
  RcvInvalidRequest:                                 0
  RcvUNISeqMismatch:                                 0
  RcvNNISeqMismatch:                                 0
  UNISignallingTimeout:                              0
  NNISignallingTimeout:                              0
  FramesCLLM:                  0                     0
  BytesCLLM:                   0                     0
  CLLMFailures:                                 0
 
 
spirit3.1.20.FRSM.a >
 

xdspportq

The xdspportq command displays queue information for a specified port and egress queue on the AUSM.

Full Name

Display a Specified Egress Queue on the Specified Port.

Syntax

xdspportq -pt <port number> -pqn <egress queue number>

where:

port number

port number is in the range 1-8

egress queue number

egress queue number is in the range 1-16

Related Commands

dspportq, dspportqs

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Any Privilege: 1-6

Example
spirit3.1.22.AUSM8.a > xdspportq -pt 1 -pqn 1
Description

Display queue information for egress queue 1 on port 1.

System Response
  ServicePortNum:                 1
  QueueNumber:                    1
  PortBinState:                   Disable
  ServiceSequence:                255
  QueueDepth(cells):              500
  CLPThresholdHigh(cells):        450
  CLPThresholdLow(cells):         400
  EFCIThreshold(cells):           400
  QueueAlgorithm:                 255
  MaxBandwidthIncrement:          4096
  MinBandwidthIncrement:          0
  QCLPState:                      Low
  QFullDiscardedCells:            0
  CLPSetDiscardedCells:           0

xdspportqs

This command displays queue information for all the egress queues on an AUSM port.

Full Name

Display All Egress Queues on a Specified Port

Syntax

xdspportqs <port number>

where:

port number

port number is in the range 1-8

Related Commands

dspportqs, xdspportq, dspportq

Cards on Which This Command Executes

AUSM

Attributes

Log: No State: Any Privilege: 1-6

Example

spirit.1.20.AUSM.a > xdspportqs 1

Description

Display egress queue information for all the egress queues on port 1.

System Response
Port   Q Num  State   Q-Algo Service-Seq Depth-Max  CLP-High  CLP-Low  EFCI-Thrsh
----  -----  -----   ------ ----------- ---------  --------  -------  ----------
  1     1    Enabled    3       1           200      180        160      160
  1     2    Enabled    3       2           900      800        700      700
  1     3    Enabled    3       3           900      800        700      700
  4     1    Enabled    3       1           200      180        160      160
  4     2    Enabled    3       2           900      800        700      700
  4     3    Enabled    3       3           900      800        700      700
 
 

xdspports

The xdspports command displays information on all the ports on the current card.

Full Name

Display Ports

Syntax

xdspports

Related Commands

dspport, addport, cnfport, delport, dspport

Cards on Which This Command Executes

FRSM, AUSM, CESM

Attributes

Log: No State: Any Privilege: 1-6

Example 1

spirit.1.17.FRSM.a > xdspports

Description

Display the ports on the current FRSM.

System Response
   Port    Ena/Speed EQService  SignalType  T391 T392 N391 N392 N393 InAlarm
                       Ratio
  --------  --- ----- --------- ------------ ---- ---- ---- ---- ---- -------
  17.2.1    Add/1536k    1      NoSignalling   10   15    6    3    4   No
  17.2.2    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.3    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.4    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.5    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.6    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.7    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.8    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.9    Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.10   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.11   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.12   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.13   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.14   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.15   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.16   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.17   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.18   Add/  64k    1      NoSignalling   10   15    6    3    4   No
  17.2.19   Add/  64k    1      NoSignalling   10   15    6    3    4   No
Example 2
wilco.1.1.FRSM.a > xdspports
Description

Display the ports on the current FRSM (FRSM-8E1 in slot 1).

System Response
    Port   Ena/Speed EQServ  SignalType  T391 T392 N391 N392 N393   Type   AlarI
                     Ratio
  -------- --- ----- ------ ------------ ---- ---- ---- ---- ---- -------- -----
  1.1.1    Add/  64k   1    NoSignalling   10   15    6    3    4 frameRel  Yesf
 
  Number of ports:              1
 
  PortDs0UsedLine1:             0x00000001
  PortDs0UsedLine2:             0x00000000
  PortDs0UsedLine3:             0x00000000
  PortDs0UsedLine4:             0x00000000
  PortDs0UsedLine5:             0x00000000
  PortDs0UsedLine6:             0x00000000
  PortDs0UsedLine7:             0x00000000
  PortDs0UsedLine8:             0x00000000
  PortNumNextAvailable:         11
 

xdspred

The xdspred command displays the current redundant slot links.

Full Name

Display Redundancy

Syntax

xdspred

Related Commands

addred, delred, dspred, xcnfred

Cards on Which This Card Executes

PXM

Attributes

Log: No State: Active Privilege: SuperUser

Example
spirit.1.7.PXM.a > xdspred
Description

Display the current redundant slot links on the switch.

System Response
  Primary  Primary  Primary  Secondary  Secondary  Secondary  Red.  Red.Slot
  SlotNum   Type     State    SlotNum     Type       State    Type   Cover
  -------  -------  -------  ---------  ---------  ---------  ----  --------
    3      FRSM-8T1  Active      4        FRSM-8T1   Standby   1:N     0
 
spirit.1.7.PXM.a >
 

xdspshelf

This command displays characteristics of the shelf information on card and line status.

Full Name

Display Shelf

Syntax

xdspshelf

Related Commands

dspshelf

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: 1-6

Example
spirit.1.8.PXM.a > xdspshelf
Description

Display characteristics of the shelf information on card and line status.

System Response
 
    NumOfValidEntries:    32
    NodeName:             spirit
    Date:                 01/29/1999
    Time:                 18:12:48
    TimeZone:             GMT
    TimeZoneGMTOff:       0
    StatsMasterIpAddress: 0.0.0.0
    shelfIntegratedAlarm: Clear
    BkplnSerialNum:       12345
    BkplnType:            2
    BkplnFabNumber:
    BkplnHwRev:           80
 
spirit.1.8.PXM.a >
 

xdspsrmlink

The xdspsrmlink command displays a link on a T3 line on a SRM-3T3 card.

Full Name

Display Link

Syntax

xdspsrmlink <T3 line number>

where:

T3 line number

SRM-3T3 T3 line number is in the format slot.line, where slot is either 15 or 31, and line is in the range 1-3)

Related Commands

dellink, addlink

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit4.1.7.PXM.a > xdspsrmlink 1
 
Description

Display characteristics of the SRM T3 link.

System Response

T3Line StartT TRowStatus TargetSlot TargetSlotLine

1

1

Add

7

1

1

2

Add

7

2

1

3

Add

7

3

1

4

Add

7

4

xdsptrapmgr

The xdsptrapmgr command displays a list of all the SNMP managers that receive traps.

Full Name

Display Trap Manager

Syntax

xdsptrapmgr

Related Commands

cnftrapmgr

Cards on Which This Command Executes

PXM

Attributes

Log: No State: Any Privilege: Any

Example
spirit.1.8.PXM.a > xdsptrapmgr
Description

Display a list of all the SNMP Managers that receive traps.

System Response
     ipAddress     PortNum  RowStatus   ReadTrapFlag  NextTrapSeqNum
  ---------------  -------  ----------  ------------  --------------
  192.168.3.251      2500       Add           Off       571
  192.168.3.254      2500       Add           Off       631
 
  LastTrapSeqNum:  631
  NumOfValidEntries:  2
 
 

xupport

This command ups a port. No messages appear on screen unless an error occurs.

Full Name

Up Port

Syntax

xupport -pt <PortNum> -ptyp <PortType> -ln <PhysLineNum> -e <PortEnable>

where:

PortNum

Port Number = 1-8

PortTyp

Port Type = 1-2, where 1 = NNI, 2 = UNI

PhysLineNum

Physical Line Number = 1-8

PortEnable

Port Enable = 1-2, where 1 = disable, 2 = enable

Related Commands

upport, xdnport, dnport

Cards on Which This Command Executes

AUSM

Attributes

Log: Yes State: Active Privilege: 1

Example
spirit3.1.22.AUSM8.a > xupport -pt 1 -e 2 -ptyp 1 -ln 1
Description

Up port 1 on physical line 1 on the AUSM in slot 22 as an NNI port.

System Response

None. No messages appear on screen unless an error occurs.