This chapter describes those Management Information Base (MIBs) supported by PXM45 Version 2.0. Existing MIBs include those public MIBs that are part of the Internet Official Protocol Standards and are published as Request for Comments (RFC) text files. Another category of existing MIBs are Cisco Enterprise MIBs, which are common for Cisco products. In both categories, PXM45 implementation does not support all of the tables defined in a particular MIB.
This chapter includes the following sections:
Note that not all of the objects in a MIB are supported by PXM45. Table 1-1 shows the standard MIBs supported by PXM45. Restrictions on the use of these MIBs are listed in Table 1-4.
| MIB | RFC Number | MIB File Name | Supported Objects |
|---|---|---|---|
RFC 2233 | IF-MIB.my | ||
RFC2 737 | ENTITY-MIB.my | ||
RFC 1659 | RS-232-MIB.my | ||
SNMP v2 MIB | RFC 1907 | SNMPv2-MIB.my | All the objects |
RFC 2578 | |||
RFC 2579 | |||
RFC 2580 |
Table 1-2 lists the Cisco Enterprise MIBs supported by PXM45.
![]() |
Note Not all of the objects in a MIB are supported by PXM45. |
| MIB | MIB File Name | Supported Objects |
|---|---|---|
CISCO-ENTITY-FRU-CONTROL- | ||
CISCO-ENTITY-SENSOR-MIB.my | All the objects | |
CISCO-PRODUCTS-MIB.my | Only OIDs1 used for sysObjectID object for MSSBU products | |
CISCO-SMI.my | CISCO-Specific Structure of Management Information | |
CISCO-TC.my | CISCO-Specific Textual Conventions | |
CISCO-SYSTEM-MIB.my | All the objects | |
CISCO-ENTITY-VENDORTYPE- | Those OIDs used for entphysicalVendorType Object for MSSBU products | |
CISCO-VSI-CONTROLLER-MIB.my | All the objects |
| 1OID is defined as object identifiers. |
The StrataCom Enterprise MIBs supported in PXM45 are part of the AXIPOP-MIB.my file. These are listed in Table 1-3.
| MIB | MIB File Name | Supported Objects |
|---|---|---|
RTM-MIB.my | All the objects | |
ERROR-STATUS-MIB.my | All the objects | |
|
For Shelf and Redundancy Table | BASIS-SHELF-MIB.my | |
BASIS-GENERIC-MIB.my | ||
GENERICOBJECT-MIB.my |
For certain standard MIB objects, the access defined in the MIB and the access as implemented in PXM45 are different, with a different default value in certain cases. These constitute MIB support limitations.
Table 1-4 lists the MIB supported limitation objects. In all cases, the access defined by the MIB is for read-write, while only read-only is supported in the PXM45.
| MIB | MIB File Name | Unsupported Table/Objects |
|---|---|---|
SNMPv2-MIB.my | ||
IF-MIB.my |
All the deprecated Objects | |
ENTITY-MIB.my | ||
CISCO-ENTITY-FRU-CONTROL-MIB.my | ||
BASIS-SHELF-MIB.my | ||
BASIS-GENERIC-MIB.my | all the objects except moduleTrapAlarmSeverity | |
GENERICOBJECT-MIB.my |
This MIB contains OID1 assignments for CISCO components for use by ENTITY-MIB. This MIB module defines the object identifiers that are assigned to various components on Cisco products, which are used by the entPhysicalTable of the ENTITY-MIB to uniquely identify the type of each physical entry.
Table 1-5 lists the values for entPhysicalVendorType object in the switch.
Table 1-5 lists the OID1 assignments for chassis, backplane, slots, and fans.
| Component Name | OID1 Name | OID1 Value |
|---|---|---|
MGX 8850 Chassis | cevChasis 86 | |
BPX SES Chassis | cevchassis | cevChassis 101 |
MGX 8850 Backplane | cevBackplane 9 | |
BPX-SES Backplane | cevBackplaneBPXSES | cevBackplane 11 |
Processor Switch Module (PXM) Slot | cevContainer 31 | |
Service Module (SM) Slot | cevContainer 32 | |
Service Redundancy Module (SRM) Slot | cevContainerSrmSlot | cevContainer 34 |
MGX 8800 Fan Tray (9 Fans) | cevContainer 33 | |
SES Fan Tray (8 Fans) | sevContainerSESFanTray | cevContainer 36 |
MGX 8800 AC Power Supply Tray | cevContainer 35 | |
MGX 8800 Single Pulse Fan | cevFan 4 | |
MGX 8800 Dual Pulse Fan | cevFan 5 | |
MGX 8800 Power Entry Module (PEM) | cevPowerSupply 17 | |
MGX 8800 Temperature Sensor | cevSensor 11 | |
MGX 8800 Power Supply Voltage Level Monitor (DC Level Monitor) | cevSensor 12 | |
Fan Speed Sensor for MGX 8850, SES | cevSensor 13 | |
Alternating Current (AC) Power Supply, 1200 Watts | cevPowerSupply 10 | |
Alternating Current (AC) Power Supply, 1050 Watts | cevPowerSupply 23 |
| 1OID is defined as an object identifier. |
Table 1-6 lists the OID1 assignments for Front Modules as defined in CISCO-ENTITY-VENDORTYPE-OID-MIB.
| Component Name | OID1 Name | OID1 Value |
|---|---|---|
PXM1 Module | cevCpuPSM1Gps | cevModuleCpuType 12 |
PXM1-2-T3E3 | cevCpuPsm12t3e3 | cevModuleCpuType 16 |
PXM1-4-155 | cevCpuPsm14oc3 | cevModuleCpuType 17 |
PXM1-622 | cevCpuPsm11oc12 | cevModuleCpuType 18 |
cevModuleCpuType 13 | ||
cevModuleWASCommonCards 9 | ||
cevModuleWASCommonCards 11 | ||
cevModuleWASCommonCards 12 | ||
cevModuleWASCommonCards 13 |
| 1OID is defined as an object identifier. |
Table 1-7 lists the OID1 assignments for Line Modules.
| Component Name | OID1 Name | OID1 Value |
|---|---|---|
cevModuleWASBackCards 11 | ||
PXM-HD | cevLmPsmHD | cevModuleWASBackCards 28 |
cevModuleWASBackCards 17 | ||
cevModuleWASBackCards 12 | ||
cevModuleWASBackCards 13 | ||
cevModuleWASBackCards 14 | ||
cevModuleWASBackCards 15 | ||
cevModuleWASBackCards 16 | ||
SMFIR-1-2488 | cevModuleWASBackCards 26 | |
cevModuleWSBackCards 27 | ||
SMFSR-1-2488 | cevLmSmfSrloc48 | cevModuleWASBackCards 34 |
SMFXLR-1-2488 | cevLmSmfXlrloc48 | cevModuleWASBackCards 35 |
SMFIR-2-622 | cevModuleWASBackCards 32 | |
SMFLR-2-622 | cevModuleWASBackCards 33 | |
SMFLR-1-622/C | cevModuleWASBackCards 42 | |
SMFLR-1-622/C | cevLmSmfLr1Oc12C | cevModuleWASBackCards 43 |
SMFIR-4-155/C | cevLmSmfIr4Oc3C | cevModuleWASBackCards 45 |
SMFLR-4-155/C | cevLmSmfLr4Oc3C | cevModuleWASBackCards 46 |
MMF-8-155 | cevModuleWASBackCards 23 | |
SMFIR-8-155 | cevModuleWASBackCards 24 | |
SMFLR-8-155 | cevModuleWASBackCards 25 | |
cevModuleWASBackCards 29 | ||
cevModuleWASBackCards 30 | ||
cevModuleWASBackCards 31 |
| 1OID is defined as an object identifier. |
The Cisco Products MIB contains OID1 assignments to use for the SNMPv2-MIB. This module defines the object identifiers that are assigned to various Cisco products. The sysObjectID values are assigned to the MGX series.
Table 1-8 lists the OID1 assignments for the switch.
| Product Name | OID1 Name | OID1 Value |
|---|---|---|
MGX 8850 | ciscoMGX8850 | ciscoProducts 228 |
| 1OID is defined as an object identifier. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Sep 15 11:53:56 PDT 2000