cc/td/doc/product/wanbu/mgx8850/20x
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

MIBs Supported

MIBs Supported

This chapter describes those Management Information Base (MIBs) supported by PXM45 Version 2.0. Existing MIBs include those public MIBs that are part of the Internet Official Protocol Standards and are published as Request for Comments (RFC) text files. Another category of existing MIBs are Cisco Enterprise MIBs, which are common for Cisco products. In both categories, PXM45 implementation does not support all of the tables defined in a particular MIB.

This chapter includes the following sections:

Standard MIBs

Note that not all of the objects in a MIB are supported by PXM45. Table 1-1 shows the standard MIBs supported by PXM45. Restrictions on the use of these MIBs are listed in Table 1-4.


Table 1-1: Standard MIBs in PXM45
MIB RFC Number MIB File Name Supported Objects

IF MIB

RFC 2233

IF-MIB.my

ifTable, ifXTable

ENTITY MIB

RFC2 737

ENTITY-MIB.my

entPhysicalTable

entPhysicalContainsTable

entLastChangeTime

RS 232 MIB

RFC 1659

RS-232-MIB.my

rs232Number

rs232PortTable

rs232AsyncPortTable

SNMP v2 MIB

RFC 1907

SNMPv2-MIB.my

All the objects

SNMP v2 SMI

RFC 2578

SNMPv2-SMI.my

Object Identifier Definitions

SNMP v2 TC

RFC 2579

SNMPv2-TC.my

Textual Conventions used in MIBs

SNMP v2 CONF

RFC 2580

SNMPv2-CONF.my

Conformance Statements used in MIBs

Cisco Enterprise MIBs

Table 1-2 lists the Cisco Enterprise MIBs supported by PXM45.


Note   Not all of the objects in a MIB are supported by PXM45.


Table 1-2: Cisco Enterprise MIBs in PXM45
MIB MIB File Name Supported Objects

CISCO FRU CONTROL MIB

CISCO-ENTITY-FRU-CONTROL-
MIB.my

cefcModuleTable

SENSOR MIB

CISCO-ENTITY-SENSOR-MIB.my

All the objects

CISCO PRODUCTS MIB

CISCO-PRODUCTS-MIB.my

Only OIDs1 used for sysObjectID object for MSSBU products

CISCO SMI

CISCO-SMI.my

CISCO-Specific Structure of Management Information

CISCO TC

CISCO-TC.my

CISCO-Specific Textual Conventions

CISCO SYSTEM MIB

CISCO-SYSTEM-MIB.my

All the objects

ENTITY VENDORTYPE MIB

CISCO-ENTITY-VENDORTYPE-
MIB.my

Those OIDs used for entphysicalVendorType Object for MSSBU products

CISCO VSI CONTROLLER

CISCO-VSI-CONTROLLER-MIB.my

All the objects

1OID is defined as object identifiers.

StrataCom® Enterprise MIBs

The StrataCom Enterprise MIBs supported in PXM45 are part of the AXIPOP-MIB.my file. These are listed in Table 1-3.


Table 1-3: StrataCom Enterprise MIBs in PXM45
MIB MIB File Name Supported Objects

RTM MIB

RTM-MIB.my

All the objects

ERROR STATUS MIB

ERROR-STATUS-MIB.my

All the objects

BASIS SHELF MIB:

For Shelf and Redundancy Table

BASIS-SHELF-MIB.my

statsMasterIpAddress

statsCollectionInterval

statsBucketInterval

userName

shelfIntegratedAlarm

shelfNum

redPrimarySlotNum

redRowStatus

redPrimaryState

redSecondarySlotNum

redSecondaryState

redType

redCoveringSlot

MODULE MIB for TRAPS

BASIS-GENERIC-MIB.my

moduleTrapAlarmSeverity

GENERIC MIB for TRAPS

GENERICOBJECT-MIB.my

genericTimeStamp

MIB Support Restrictions

For certain standard MIB objects, the access defined in the MIB and the access as implemented in PXM45 are different, with a different default value in certain cases. These constitute MIB support limitations.

Table 1-4 lists the MIB supported limitation objects. In all cases, the access defined by the MIB is for read-write, while only read-only is supported in the PXM45.


Table 1-4: MIB Support Limitations
MIB MIB File Name Unsupported Table/Objects

SNMPv2 MIB

SNMPv2-MIB.my

sysORLastChange

sysORTable

IF MIB

IF-MIB.my

ifInNUcastPkts

ifOutNUcastPkts

ifOutQLen

ifSpecific

ifHCInOctets

ifHCInUcastPkts

ifHCInMulticastPkts

ifHCInBroadcastPkts

ifHCOutOctets

ifHCOutUcastPkts

ifHCOutMulticastPkts

ifHCOutBroadcastPkts

ifTableLastChange

ifStackTable

linkDown TRAP

linkUp Trap

All the deprecated Objects

ENTITY MIB

ENTITY-MIB.my

entPhysicalAssetID

entPhysicalAlias

entLogicalTable

entLPMappingTable

entAliasMappingTable

entConfigChange TRAP

CISCO ENTITY FRU CONTROL MIB

CISCO-ENTITY-FRU-CONTROL-MIB.my

cefcFRUPowerSupplyGroupTable

BASIS SHELF MIB

BASIS-SHELF-MIB.my

redPrimaryType

redSecondaryType

redFeature

redLineModuleType

shelfTable

shelfNumValidEntries

shelfDate

shelfTime

shelfTmZn

shelfTmZnGMTOff

shelfBkplnType

shelfBkplnSerialNum

shelfAlarmCardBitMap

apsIpAddress

redundantApsIpAddress

axisFeederTkNo

axisSvcBillingColInterval

axisSvcBillingBucketInterval

axisSvcBilling

BASIS GENERIC MIB

BASIS-GENERIC-MIB.my

all the objects except moduleTrapAlarmSeverity

GENERICOBJECT MIB

GENERICOBJECT-MIB.my

genericLineNum

genericLineType

OID Assignments

This MIB contains OID1 assignments for CISCO components for use by ENTITY-MIB. This MIB module defines the object identifiers that are assigned to various components on Cisco products, which are used by the entPhysicalTable of the ENTITY-MIB to uniquely identify the type of each physical entry.

Table 1-5 lists the values for entPhysicalVendorType object in the switch.

Chassis, Backplane, Slots, and Fans

Table 1-5 lists the OID1 assignments for chassis, backplane, slots, and fans.


Table 1-5: OID1 Assignments—Chassis, Backplane, Slots, and Fans
Component Name OID1 Name OID1 Value

MGX 8850 Chassis

cevChassisMGX8850

cevChasis 86

BPX SES Chassis

cevchassis

cevChassis 101

MGX 8850 Backplane

cevBackplaneMGX8850

cevBackplane 9

BPX-SES Backplane

cevBackplaneBPXSES

cevBackplane 11

Processor Switch Module (PXM) Slot

cevContainerPsmSlot

cevContainer 31

Service Module (SM) Slot

cevContainerSmSlot

cevContainer 32

Service Redundancy Module (SRM) Slot

cevContainerSrmSlot

cevContainer 34

MGX 8800 Fan Tray (9 Fans)

cevContainerMGX8800FanTray

cevContainer 33

SES Fan Tray (8 Fans)

sevContainerSESFanTray

cevContainer 36

MGX 8800 AC Power Supply Tray

cevContainerMGX8800ACPSTray

cevContainer 35

MGX 8800 Single Pulse Fan

cevFanSinglePulse

cevFan 4

MGX 8800 Dual Pulse Fan

cevFanDualPulse

cevFan 5

MGX 8800 Power Entry Module (PEM)

cevPowerSupplyMGX8800Pem

cevPowerSupply 17

MGX 8800 Temperature Sensor

cevSensorMGX8800Temp

cevSensor 11

MGX 8800 Power Supply Voltage Level Monitor (DC Level Monitor)

cevSensorMGX8800PSVoltage

cevSensor 12

Fan Speed Sensor for MGX 8850, SES

cevSensorMGX8800FanSpeed

cevSensor 13

Alternating Current (AC) Power Supply, 1200 Watts

cevPowerSupplyAC1200W

cevPowerSupply 10

Alternating Current (AC) Power Supply, 1050 Watts

cevPowerSupplyAC1050W

cevPowerSupply 23

1OID is defined as an object identifier.

Front Modules

Table 1-6 lists the OID1 assignments for Front Modules as defined in CISCO-ENTITY-VENDORTYPE-OID-MIB.


Table 1-6: OID1 Assignments—Front Modules
Component Name OID1 Name OID1 Value

PXM1 Module

cevCpuPSM1Gps

cevModuleCpuType 12

PXM1-2-T3E3

cevCpuPsm12t3e3

cevModuleCpuType 16

PXM1-4-155

cevCpuPsm14oc3

cevModuleCpuType 17

PXM1-622

cevCpuPsm11oc12

cevModuleCpuType 18

PXM45

cevCpuPSM45Gbps

cevModuleCpuType 13

AXSM-1-2488

cevAxsm1Oc48

cevModuleWASCommonCards 9

AXSM-8-155

cevAxsm8Oc3

cevModuleWASCommonCards 11

AXSM-16-155

cevAxsm16Oc3

cevModuleWASCommonCards 12

AXSM-16-T3E3

cevAxsm16T3E3

cevModuleWASCommonCards 13

1OID is defined as an object identifier.

Line Modules

Table 1-7 lists the OID1 assignments for Line Modules.


Table 1-7: OID1 Assignments—Line Modules
Component Name OID1 Name OID1 Value

PXM-UI

cevLmPsmUI

cevModuleWASBackCards 11

PXM-HD

cevLmPsmHD

cevModuleWASBackCards 28

PXM-UI-S3

cevLmS3Ui

cevModuleWASBackCards 17

MGX-MMF-4-155

cevLmMmf4oc3

cevModuleWASBackCards 12

MGX-SMFIR-4-155

cevLmSmfIr4oc3

cevModuleWASBackCards 13

MGX-SMFLR-4-155

cevLmSmfLr4oc3

cevModuleWASBackCards 14

MGX-SMFIR-1-622

cevLmSmfIr1oc12

cevModuleWASBackCards 15

MGX-SMFLR-1-622

cevLmSmfLrloc12

cevModuleWASBackCards 16

SMFIR-1-2488

cevLmSmfIr1oc48

cevModuleWASBackCards 26

SMFLR-1-2488

cevLmSmfLr1oc48

cevModuleWSBackCards 27

SMFSR-1-2488

cevLmSmfSrloc48

cevModuleWASBackCards 34

SMFXLR-1-2488

cevLmSmfXlrloc48

cevModuleWASBackCards 35

SMFIR-2-622

cevLmSmfIr2oc12

cevModuleWASBackCards 32

SMFLR-2-622

cevLmSmfLr2oc12

cevModuleWASBackCards 33

SMFLR-1-622/C

cevLmSmfIr1Oc12C

cevModuleWASBackCards 42

SMFLR-1-622/C

cevLmSmfLr1Oc12C

cevModuleWASBackCards 43

SMFIR-4-155/C

cevLmSmfIr4Oc3C

cevModuleWASBackCards 45

SMFLR-4-155/C

cevLmSmfLr4Oc3C

cevModuleWASBackCards 46

MMF-8-155

cevLmMmf8oc3

cevModuleWASBackCards 23

SMFIR-8-155

cevLmSmfIr8oc3

cevModuleWASBackCards 24

SMFLR-8-155

cevLmSmfLr8oc3

cevModuleWASBackCards 25

SMB-8-T3

cevLmSmb8t3

cevModuleWASBackCards 29

SMB-8-E3

cevLmSmb8e3

cevModuleWASBackCards 30

SMB-4-155

cevLmSmb4stm1

cevModuleWASBackCards 31

1OID is defined as an object identifier.

Cisco Products MIB

The Cisco Products MIB contains OID1 assignments to use for the SNMPv2-MIB. This module defines the object identifiers that are assigned to various Cisco products. The sysObjectID values are assigned to the MGX series.

Product Object Identifiers

Table 1-8 lists the OID1 assignments for the switch.


Table 1-8: Product Specific Object Identifiers
Product Name OID1 Name OID1 Value

MGX 8850

ciscoMGX8850

ciscoProducts 228

1OID is defined as an object identifier.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Fri Sep 15 11:53:56 PDT 2000