cc/td/doc/product/wanbu/mgx8850/20x
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

PNNI Traps

PNNI Traps

This chapter describes the traps specific to PNNI.

Contents of this chapter include:

PNNI-Specific Traps

Table 5-1 provides descriptions of the supported traps PNNI-specific traps.


Note   All mandatory trap varbinds are described inTable 5-2. For a description of each miscellaneous trap varbind, see Table 5-3.


Table 5-1: PNNI List of Traps
Name Number Specific-Varbinds Description

ciscoWANSscopLinkChange

70003

ifIndex, cwspPhyIdentifier, cwspSscopStatus

Specifies if the Sscop link status is failed or established.

ciscoWANControllerStateChange

70004

cwspPnniControllerStatus, cwspPnniControllerPhySlot

Indicates the PNNI controller is active or standby.

ciscoWANIntfAddTrap

70005

ifIndex, cwspPhyIdentifier

Adds an interface.

ciscoWANIntfDeleteTrap

70006

ifIndex, cwspPhyIdentifier

Deletes an interface.

ciscoWANIntfConfigurtaion
ChangeTrap

70007

ifIndex, cwspPhyIdentifier

Changes the configuration for an interface.

ciscoWANIntfOperationChange
Trap

70008

ifIndex, cwspPhyIdentifier, cwspOperStatus, cwspOperIfcType, cwspOperFailReason

Changes the operation status for an interface.

ciscoWANSpvcFailTrap

70009

ifIndex, cwspConnTraceSrcVpi, cwspConnTraceSrcVci, cwspCallCallingAddress, ciscoWANSpvcFailReason

Indicates the Soft Permanent Virtual Connection (SPVC) failure that is recognized in the PNNI controller.

ciscoWANPnniControllerStndby
Failed

70010

cwspPnniControllerPhySlot

Indicates the PNNI standby controller failed.

ciscoWANSpvcNodePrefix
Change

70011

cwspSpvcNodePrefix

Specifies the PNNI controller can send this notification when the SPVC node prefix is changed. The cwspSpvcNodePrefix can contain the updated prefix.

Mandatory Trap Varbinds

Table 5-2 lists the trap variables (varbinds) in each trap generated by the switch. Each of these varbinds, in the order given, is available for each trap generated.


Table 5-2: Mandatory Trap Varbinds
Varbind Data Type Description

lastSequenceNumber

INTEGER

Contains the sequence number assigned to the trap. This can be used by Network Management System (NMS) applications to implement a Robust Trap Mechanism.

sysName

OctetString

Contains the node name of the switch.

entPhysicalContainedIn

INTEGER(0..2147483647)

Contains the chassis number into which the module is connected.

entPhysicalParentRelPos

INTEGER(-1..2147483647)

Contains the physical slot number to into which the module is connected.

entPhysicalVendorType

ObjectID

Contains the type of module for which the trap is generated.

moduleTrapAlarm Severity

INTEGER ( enumeration)

Contains the alarm severity of the trap.

genericTimeStamp

OctetString(1..30)

Contains the time when the trap is generated.

Trap-Specific Varbinds

Table 5-3 lists the trap-specific varbinds.


Note   These trap varbinds are not available for all the traps.


Table 5-3: PNNI Trap-Specific Varbinds
Varbind Data Type Description

ifIndex

Integer32(1..2147483647)

Specifies a unique value, greater than zero, for each interface. It is recommended that values are assigned starting with one.

ifName

OctetString(0..255)

Specifies the textual name of the interface.

cwspPhyIdentifier

OctetString(0..255)

Indicates the physical identification of the interface.

cwspSscopStatus

INTEGER

Specifies the Sscop link status on an Network-to-Network Interface (NNI).

cwspPnniControllerStatus

INTEGER (enum)

Specifies the administrative status of the PNNI controller.

cwspPnniControllerPhySlot

Integer32

Specifies the PNNI controller physical location.

cwspOperStatus

INTEGER

Specifies the operational state of the interface.

cwspOperIfcType

INTEGER

Specifies the interface type.

cwspOperFailReason

INTEGER

Defines the SVC port failures.


Note   This object is used only for a trap varbind.

NMS applications should not use issue SNMP get and get-next requests for this object.

cwspConnTraceSrcVpi

Integer32(0..4095)

Shows the VPI value of the starting point on this interface.

cwspConnTraceSrcVci

Integer32(0..65535)

Shows the VCI value of the starting point on this interface.

cwspCallCallingAddress

OctetString

Shows the calling party address of the call.

ciscoWANSpvcFailReason

INTEGER (enumeration)

Defines the SPVC manager failures.


Note   This object is used only for a trap varbind.

NMS applications should not depend on the impenmentation of this object. SNMP get and get-next requests are not valid for this object.

cwspSpvcNodePrefix

OctetString(13..13)

Specifies that write access is currently not permitted.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Fri Sep 15 11:18:54 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.