Preparing for Configuration

Preparing for Configuration

This chapter introduces common MGX 8850 switch topologies, provides an overview of the configuration process, and presents guidelines for collecting the information you will need to complete the configuration.

Typical Topologies

Release 2.0 of the MGX 8850 switch supports the following topologies:

The following sections introduce these topologies.

Core Switch

Figure 1-1 shows the MGX 8850 switch operating in a core switch topology.


Figure 1-1: Core Switch Topology


In the core switch topology, the MGX 8850 switch works with other ATM switches to transfer broadband ATM traffic from one ATM edge device to another. The core acts like a freeway and the edge devices act like freeway on-ramps.

The MGX 8850 switch supports the following types of trunks: DS3, E3, OC-3, OC-12, OC-48, STM-1, STM-4, and STM-16. Typically, core edge nodes communicate with multiple external nodes over relatively slower broadband trunks such as DS3, OC-3, and STM-1trunks. The internal core node communicates with other core nodes using relatively faster links such as OC-12, OC-48, and STM-16 trunks.

Multiservice Edge Aggregation

Figure 1-2 shows the MGX 8850 switch operating in a multiservice edge aggregation topology.


Figure 1-2: Multiservice Edge Aggregation Topology


In the multiservice edge aggregation topology, the MGX 8850 switch is colocated with other ATM equipment and communicates with one or more core switches at remote locations. The MGX 8850 switch aggregates the traffic from multiple local ATM devices, and packages it for high-speed communications over the core.

Typically, multiservice edge nodes communicate with colocated ATM devices over relatively slower broadband trunks such as DS3 and E3 trunks. The multiservice edge node communicates with core nodes using relatively faster links such as OC-12, OC-48, and STM-16 trunks.

The MGX 8850 Release 1 node shown in Figure 1-2 is called a feeder node. For instructions on configuring the MGX 8850 Release 2 switch to communicate with an MGX 8850 Release 1 feeder node, see "Provisioning."

MGX 8850 edge nodes also support virtual trunks as shown in Figure 1-3.


Figure 1-3: Virtual Trunk Topology


A virtual trunk provides a private virtual network path through an independent network such as a public ATM network. Using virtual trunks, Company A can establish a private virtual path between two sites using a public ATM network that supports this feature. From Company A's point of view, they have a private virtual path between the two sites that can support multiple virtual circuits (VCs). Company A's network topology is completely private, as all communications are simply passed between edge devices, with no need for translation or routing. To accomplish this, the virtual trunk supports the SSCOP (VCI=5), PNNI (VCI=18) and ILMI (VCI=16) signaling protocols.

Figure 1-3 shows two virtual trunks, Virtual Trunk A and Virtual Trunk B. At Private Switch A, both virtual trunks use the same line to connect to the core ATM network. Within the core ATM network, Soft Virtual Permanent Paths (SPVPs) are defined to enable direct communications between the core edge nodes. The result is that Private Switch A has virtual trunks to Private Switches B and C and communicates with them as though they were directly connected to Private Switch A.

DSL Aggregation

Figure 1-4 shows the MGX 8850 switch operating in a Digital Subscriber Link (DSL) edge aggregation topology.


Figure 1-4:
DSL Edge Aggregation Topology


In the DSL edge aggregation topology, the MGX 8850 switch is colocated with Digital Subscriber Line Access Multiplexers (DSLAMs) and communicates with one or more core switches at remote locations. The MGX 8850 switch aggregates the DSL traffic from multiple DSLAMs, and packages it for high-speed communications over the core.

Typically, DSL edge nodes communicate with colocated DSLAMs over relatively slower broadband trunks such as DS3 and E3 trunks. The DSL edge node communicates with core nodes using relatively faster links such as OC-3, OC-12, and OC-48 trunks.

Configuration Tasks

Switch configuration is easier if you are familiar with the overall configuration process. To configure and start up the MGX 8850 switch, you need to do some or all of the following:

"Configuring General Switch Features," describes how to set up general switch features such as the date, the PNNI controller, and network management. You need to follow the procedures in this chapter to prepare your switch for general operation.

"Preparing AXSM Cards and Lines for Communication," describes how to configure card and line redundancy, and how to bring up lines for physical layer communications.

"Provisioning," describes how to configure ATM communications on the lines and how to configure different types of connections.

For instructions on configuring different ways to manage the MGX 8850 switch, see "Supporting and Using Additional CLI Access Options."

Collecting Information

To successfully configure the MGX 8850 switch, you must collect information about the other devices to which it will connect. You need to know the line speeds and protocols used on the trunks that connect to the switch. You also need to know addressing plan for the network in which the switch is installed. This information can be grouped into the following categories:

The following sections introduce these types of data and provide guidelines for collecting the data you need for switch configuration.

General Configuration Data

During configuration, you will need to enter general configuration data that describes the switch and how it will be used in the network. This data includes

The following sections describe these topics in more detail.

Unique Switch Name

Each switch must have its own unique name (which consists of up to 32 characters) within the ATM network. If you are adding a switch to a network, find out if the network administrator has established switch naming conventions, and find out which names have already been used. It is a good practice to name switches according to location, as this conveys both the switch identity and its location. The procedure for setting the name is described in "Setting and Viewing the Switch Name" in "Configuring General Switch Features."

Network Addressing Plan

A network addressing plan is critical for successful operation of the MGX 8850 switch in an ATM network. The Private Network-to-Network Interface (PNNI) protocol uses structured network addresses to logically group network devices and determine routes between devices.

PNNI network addressing is described in "Guidelines for Creating an Address Plan," which appears later in this chapter.

Administrator Data

In most cases, more than one administrator will manage the switch. The MGX 8850 switch supports multiple administrators and several different administration levels. As part of the planning process, you might want to identify who will be managing the switch and at what level. You can learn more about managing administrators by reading "Configuring User Access" in "Configuring General Switch Features."

Network Clock Source Plan

Clock synchronization in an ATM network is very important. If two switches have trouble synchronizing their communications, traffic between the switches may slow down or stop. Figure 1-5 shows an example network clock source topology.


Figure 1-5: Example Network Clock Source Topology with a Single Master Clock Source


In Figure 1-5, Switch 1 operates as the master network clock source and uses highly accurate external Building Integrated Timing System (BITS) clock sources to time its transmissions to the other switches. These BITS clock sources are T1 or E1 lines with stratum 1, 2, or 3 clock signals. Switch 1 uses one BITS line as the primary clock source and uses the secondary BITS source only if a failure occurs on the primary BITS line. If the primary BITS line fails and recovers, the switch will revert back to the primary line.

Switches 2 through 5 synchronize their transmissions to Switch 1 with the master clock signal, which they receive over AXSM lines. Switch 6 synchronizes its communications using the master clock source, which is forwarded from Switch 3. In this topology, all switches synchronize to the same clock source, and this configuration reduces the possibility that two switches might not be able to synchronize communications.

Figure 1-6 shows an example network clock source topology that uses two master clock sources.


Figure 1-6: Example Network Clock Source Topology with Two Master Clock Sources


In Figure 1-6, Switches 1 and 2 both use BITS clock sources. Switch 1 operates as the master and distributes its BITS clock source over AXSM lines to Switches 2 through 4. Switch 2 is the standby master and receives its primary clock signal over the AXSM line from Switch 1. As long Switch 1 and its primary BITS clock source are operating correctly, the entire network is synchronized to the BITS clock source from Switch 1.

In this example, the secondary clock source for Switch 2 is its BITS clock source, and all other switches are configured to use the AXSM lines from Switch 2 as their secondary clock source. If Switch 1 or its BITS clock source fails, all the switches, including Switch 1, start using the clock signals from Switch 2 for network communications. This configuration preserves network sychronization when either a clock source or a switch fails.

To develop a network clock source plan, create a topology drawing and identify which switches serve as active and standby master clock sources. For each switch that receives clock sources from other switches, indicate which lines carry the primary and secondary clock signals.

When creating your network clock source plan, consider the following:

Network Management Plan

You can use the following tools to manage the Cisco MGX 8850 switch:

The Command Line Interface (CLI) that comes with the switch is the least expensive option. To use the other tools, you must purchase Cisco WAN Manager (CWM) or a Simple Network Management Protocol (SNMP) manager. The MGX 8850 switch comes with an SNMP agent for use with an SNMP manager.

The advantage to using CWM or an SNMP manager is that you can use one program to simultaneously manage multiple devices. Also, CWM is the only management tool that can configure Service Class Templates (SCTs), which are described in "Provisioning." Most installations require at least one CWM workstation to complete the switch configuration.

This guide describes how to configure and monitor the switch using the CLI. For instructions on managing the switch with CWM, refer to the following guides:

For information on managing the switch with an SNMP manager, refer to the following:

Line and Trunk Data

When configuring lines and trunks that connect the switch to other devices, you need to collect the following types of data:

The MGX 8850 switch supports many of the most common ATM configuration parameters. To successfully configure lines and trunks, be sure that the configuration settings used on the switch match the configuration settings used at the other end of the line or trunk. In some cases, options you want to use at one end of the trunk aren't supported at the other end. In these situations, change your configuration plan to use settings that are supported at both ends. "Preparing AXSM Cards and Lines for Communication," describes how to configure physical layer line communications. "Provisioning," describes how to configure ATM ports.

Planning for Card and Line Redundancy

Card redundancy is a feature that associates two cards. If one card fails, the other card assumes operation. PXM45 card redundancy is preconfigured on the MGX 8850 switch. If PXM45 cards and their associated back cards are inserted in slots 7 and 8, they will automatically operate as redundant cards. One card assumes the active role, and the other card operates in standby mode.

AXSM cards and their associated lines can be configured for either standalone or redundant operation. Because a configuration change interrupts service and can require substantial configuration teardown, it is important to develop a redundancy plan early. The redundancy plan determines how AXSM cards must be installed in the chassis, and how lines must connect to the cards. Once the hardware is installed, the software configuration team uses the redundancy plan to configure the switch. The software configuration must match the hardware configuration.

The MGX 8850 switch supports the following card and line redundancy options:

The following sections provide planning guidelines for these configurations.

Planning Standalone AXSM Configurations with Redundant Lines

AXSM cards can operate in either standalone or redundant mode. Standalone mode is the default mode, and standalone cards can be configured for either standalone line operation or Automatic Protection Switching (APS) line operation, which uses redundant lines for fault tolerance. If a standalone AXSM card fails, all calls are lost and the associated lines go out of service. However, if the AXSM card is configured to support redundant lines, a failure on the working line causes a switchover to the protected line, and operation continues.

Figure 1-7 shows how a single AXSM card connects to redundant lines.


Figure 1-7: Standalone AXSM Configuration with Redundant Lines


The redundant lines shown in Figure 1-7 are labeled the working line and the protection line, as defined in the SONET specification for APS. The working line is the primary communications line, and the protection line is the line that will be used if the working line fails.

Two types of APS communications are supported: 1+1 and 1:1. The 1+1 communications type transmits data on both the working line and the protection line. The 1:1 communications type transmits data on either the working line or the protection line.

Notice that both the working line and the protection line connect to the same back card in Figure 1-7. This is why this configuration is also known as an intracard APS configuration. When planning an intracard APS configuration, consider the following:

Planning Redundant AXSM Configurations with Standalone Lines

In a redundant AXSM configuration, matched sets of front and back cards are installed in the switch, and redundancy is established during software configuration. In a redundant AXSM configuration, a failure on the active AXSM front card causes a switchover to the standby AXSM card set, and no calls are lost.


Note   This configuration provides fault tolerance for the AXSM front card only. This configuration does not provide fault tolerance for back cards or lines. If you need this level of protection, use the redundant AXSM configuration with redundant lines.

Figure 1-8 shows how a redundant AXSM cards connect to standalone lines.


Figure 1-8: Redundant AXSM Configuration with Standalone Lines


Figure 1-8 shows two complete sets of AXSM cards. Each port in an active card slot is connected to the corresponding port in the standby card slot through a Y-cable, which joins the two ports to a common line. If the front card in the active card set fails, the standby card set becomes active and continues to support calls over the shared communication line.

When planning a redundant AXSM configuration with a standalone line, consider the following:

Planning Redundant AXSM Configurations with Redundant Lines

Maximum fault tolerance is achieved when redundant AXSM cards are used with redundant APS lines. In this configuration, fault tolerance is provided for the front card and for the combination of the back card and the communication line. If the working line or the back card to which it is connected fails, communications traffic is rerouted through the protection line and the back card to which it is connected.

Figure 1-9 shows how a redundant AXSM cards connect to redundant APS lines.


Figure 1-9: Redundant AXSM Configuration with Redundant Lines


Figure 1-9 shows two complete sets of AXSM cards. Each port in each card slot connects to an independent line. If the front card in the active card set fails, the standby card set becomes active and continues to support calls over the shared communication line. If the working line fails, communications are rerouted through the protection line for that port.

When planning a redundant AXSM configuration with a redundant lines, consider the following:

Guidelines for Creating an Address Plan

This section lists general guidelines for creating a network address plan and explains concepts and issues that apply to PNNI operation on the MGX 8850 switch.


Note   All MGX 8850 switches ship with default addresses. These defaults are provided for lab evaluations of the MGX 8850 switch. Before the switch is deployed, Cisco advises you to reconfigure the default addresses using the address plan guidelines in this section.

Planning Overview

At the end of this chapter, there is an Address Plan Worksheet into which you enter your WAN address values. If you are familiar with designing PNNI address structures, or if a plan is already completed, you can go directly to the Address Plan Worksheet and enter the values. Nodal address configuration is explained in "Configuring General Switch Features." Port address configuration is explained in "Provisioning."

The remainder of this chapter explains the following steps that you can use to create a WAN address plan:

    1. Selecting an Address Format.

    2. Selecting a PNNI Level.

    3. Selecting the PNNI Peer Group ID.

    4. Selecting the Node Prefix.

    5. Selecting the ATM Address.

    6. Selecting the ILMI Address Prefix.

    7. Selecting the SPVC Address Prefix.

    8. Selecting the IISP Address Prefix.

    9. Selecting Static Addresses for UNI Ports.

In a PNNI WAN, the architecture is determined by the node prefixes and addresses. PNNI nodes or peers, broadcast their addresses and prefixes to all other peers in their peer group. Prefixes are partial addresses that are used to summarize a group of addresses. Prefixes reduce overhead in a PNNI network because it is more efficient to advertise one prefix than it is to advertise a group of individual addresses.

Correct address selection will meet the critical WAN architecture goals of

Selecting an Address Format

Each PNNI node must be configured for at least one address format. To establish ATM connections, each ATM UNI end system must have at least one ATM end system address (AESA) that uniquely identifies that ATM endpoint. This section explains the supported AESA address formats and their structures.


Caution Each node must support the address format of all its neighboring nodes.

Supported Address Formats

The MGX 8850 supports the following standard ATM formats:

The native E.164 address specifies an Integrated Services Digital Network (ISDN) number and is used by public PSTNs. A native E.164 address has variable length of up to 15 BCD digits. The other address formats are usually used for private networks. The default address format for the MGX 8850 switch is the ICD format.

In the PNNI network, native E.164 addresses are mapped to an E.164 AESA format. The native AESA will be inserted as a left-justified IDI portion of the AESA, with the semi-octet Hex FFFF padded to form an integral byte at the end. This left-justified rule may be changed to right-justified via CLI if needed.

The substructures of the address formats are transparent to PNNI routing. Figure 1-10 shows the substructures of the supported ATM address formats. Table 1-1 describes the substructures shown in Figure 1-10.


Figure 1-10: Supported ATM Address Formats



Table 1-1: ATM Address Components
ATM Field Description Default Values

AFI

1-byte authority format identifier.

47

Cisco ICD

2-byte Cisco specific International Code Designator.

0091

IDI

Initial Domain Identifier. The contents of this field vary depending on the value of the AFI. For example, with a DCC AESA (AFI=39), the IDI value of Hex 840F identifies the United States.

HO-DSP

High-Order Domain Specific Part. The meaning is defined by the address authority controlling the AESA. This component couples with AFI and IDI to route a call to the appropriate switch.

ESI

6-byte end system identifier. This field repeats the PNNI Controller MAC address when the ATM address identifies the PNNI node. (When an ATM address identifies an ATM end system, the ESI field will be completed through ILMI registration with the end system. In this case, the ESI is typically the MAC address of the ATM CPE. The unique ESI field will distinguish that ATM end system [ATM CPE] from all other ATM end systems.)

PXM45 MAC address at first boot.

SEL

1-byte that is used to distinguish Classical IP interfaces that use the same physical interface. The currently supported values are 01 for PNNI and 99 for ping.

00

Guidelines for Selecting an Address Format

If an address format is already chosen for the WAN, or if your WAN will consist of existing nodes for which an address format has been selected, you can select that address format.

Both Public ATM networks (PSTNs) and Narrowband Integrated Services Digital Networks (N-ISDN) usually use E.164 numbers. This type of deployment is then configured with 11-byte IISP static addressees. PNNI will allow end-system reachability to be advertised via the E.164 address prefix.

In the Data Country Code (DCC) format, each country has a unique DCC code value. If you select this address format, your value must match this standard.

In the International Code Designator (ICD) format, the ICD identifies an organization such as a company or campus. This is a benefit if you are deploying a WAN that will be accessed by several campuses or sites.

Native E.164 addresses can be embedded in the AESA.

Enter the address format or formats that you select into the nodal address worksheet, Table 1-4, which appears at the end of this chapter.


Note   Local AFIs should NOT be used for addressing within ATM Service Provider networks.

Address Registration Authorities

Table 1-2 lists the address registration authorities.


Table 1-2: Address Registration Authorities
Category Type Authorities

ATM Service Providers
(ASPs)

ICD

    1. US—American National Standards Institute (ANSI)

    2. UK—British Standards Institution (BSI)
    Identifiers for Organizations for Telecommunications Addressing (IOTA)
    http://www.bsi.org.uk/disc/iota.html.

DCC

    1. ISO National Administrative Authority (Registration Authority)

    2. List of authorities - http://www.fei.org.uk/fei/dcc-nsap.htm

  • US—American National Standards Institute (ANSI)

  • UK—Federation of the Electronics Industry (FEI)

  • Germany—Deutsche Industrie-Normen (DIN)

E.164

International Telecommunications Union (ITU), the National Numbering Authority.

Private Networks

ASP Addresses

Private ATM networks can apply to their ATM Service Provider for addresses.

ICD

Identifiers for Organizations for Telecommunications Addressing (IOTA) http://www.bsi.org.uk/disc/iota.html.

DCC

    1. ISO National Administrative Authority (Registration Authority)

    2. List of authorities - http://www.fei.org.uk/fei/dcc-nsap.htm

Unregistered Addresses

Private networks may create unregistered addresses. Note that such addresses are not globally unique. It is recommended that unregistered addresses be formed using the local AFI (49).

Selecting a PNNI Level

The PNNI level defines the position of a switch within the PNNI network. In the current release, the MGX 8850 switch supports one network with a single PNNI level. For evaluation networks, you can accept the default PNNI level, which is 56.

However, if you are deploying the MGX 8850 switch in a production environment, you might want to select a different PNNI level that conforms with a long term PNNI deployment plan. The PNNI standard supports 2 types of topologies: Single Peer Group (SPG) and Multiple Peer Group (MPG). The following sections describe SPG and MPG issues that affect the PNNI level setting.

Single Peer Group Networks

The Cisco MGX 8850 switch currently supports only SPG WANs. Figure 1-11 shows an example topology of a PNNI Single Peer Group WAN.


Figure 1-11: Single Peer Group WAN


In a SPG network, all nodes are in the same group. Although you can configure a PNNI level, or accept the default level, you should not configure more than one level. To define all the nodes as part of the same group, the nodes must all be assigned the same level and group identification number.

Multiple Peer Group Networks

A MPG WAN uses multiple hierarchical levels to logically divide the WAN into levels and peer groups. MPG switches divide the routing database into partitions for each peer group and level. This reduces the amount of network overhead in each peer group, which allows the WAN to support more ATM devices.

Figure 1-12 shows an example topology of a PNNI Multiple Peer Group WAN.


Figure 1-12: Multiple Peer Group (MPG) WAN Topology


As shown in Figure 1-12, lower level numbers indicate peer groups at higher levels in the hierarchy. The level 40 group is highest in the architecture, yet it has a lower number than level 56, which is used by the lowest level peer groups in the example. The level numbers shown are decimal numbers that represent the binary numbers used by the switch.

Guidelines for Setting the PNNI Level

When selecting a level number, you can use any number between 0 and 104, but is generally easier to work with numbers that represent 8-bit boundaries. These numbers are listed in Table 1-3.


Table 1-3: Recommended PNNI Level Values
Level Binary Value Peer Group ID Length (Bytes)

8

0000 1000

1

16

0001 0000

2

24

0001 1000

3

32

0010 0000

4

40

0010 1000

5

48

0011 0000

6

56

0011 1000

7

64

0100 0000

8

72

0100 1000

9

80

0101 0000

10

88

0101 1000

11

96

0110 0000

12

104

0110 1000

13

As Table 1-3 shows, the PNNI level selects the length of the peer group ID, which is described in the next section. The default PNNI level for the MGX 8850 switch is in the middle of the range of values. Enter the level indicator that you select into the nodal address worksheet, Table 1-4, which appears at the end of this chapter. Remember, in this release, all nodes in the same WAN must be set to the same PNNI level.

Selecting the PNNI Peer Group ID

A node's peer group is determined by its peer group ID, which can be up to 13 bytes long. Figure 1-13 shows the default peer group ID for the MGX 8850 switch.


Figure 1-13: 20-byte Default Cisco ATM Address


As Figure 1-13 shows, the peer group ID begins with the left-most or most-significant byte of the ATM address. The PNNI level, which is introduced in the previous section, defines the length of the peer group ID. For example, the Cisco default level indicator is 56, which specifies a peer group ID that is 7 bytes long. Therefore, the default peer group ID for all MGX 8850 nodes is 47 0091 8100 0000.

When planning the peer group ID for your WAN, consider the following:

Enter the peer group ID into the nodal address worksheet, Table 1-4, which appears at the end of this chapter.

Selecting the Node Prefix

When a specific ATM address is not defined for the node, the ATM address is defined by the node prefix and the MAC address on the active PXM45 card as shown in Figure 1-13. The node prefix is the first 13-bytes of the node's AESA, and consists of the 7-byte peer group ID (0x47 0091 8100 0000) plus the unique 6-byte MAC address. This is also the default SPVC prefix and ILMI prefix.

The default node prefix also serves as the default PNNI summary address. A summary address is a prefix that PNNI advertises to summarize a group of ATM addresses. One or more summary node prefixes may be configured for each UNI port.

When planning the node prefix for your WAN, remember that the most significant bytes in the node prefix must conform to the peer group ID and PNNI levels.

Enter the node prefix into the nodal address worksheet, Table 1-4, which appears at the end of this chapter.

Selecting the ATM Address

The node ATM address must be unique on the WAN and conform to the selections you have made for the following:

To minimize address advertising overhead, the node prefix should match the first 13 bytes of the ATM address.

Figure 1-14 shows the default ATM address for the MGX 8850 switch.


Figure 1-14: 20-byte Node Address


The first byte (47) of the default address identifies the address as an International Code Designator (ICD) ATM End Station Address (AESA). The second and third bytes (0091) are the globally unique ICD assigned to Cisco, and the next four bytes (81000000) are identical for all MGX 8850 switches. The unique portion of the default node address is the 6-byte MAC address, which is used in bytes 8 through 13 and again in bytes 14 through 19. Byte 20, which is the selector byte, is set to 00 by default.

You do not have to define ATM addresses for MGX 8850 switches if the combination of the node prefix and the MAC address is acceptable. If you want to create a custom ATM address for the switch, enter the address into the nodal address worksheet, Table 1-4, which appears at the end of this chapter.


Caution The default ATM address is created using the primary PXM45 card's MAC address. If the default address is being used and the primary PXM45 card is replaced, the ATM address of the switch changes. After replacing a PXM45 card, check the switch ATM address and reconfigure it if necessary. To avoid this problem entirely, configure a unique ATM address for the switch.

Selecting the ILMI Address Prefix

The MGX 8850 switch supports ILMI dynamic addressing on UNI ports. When dynamic addressing is enabled, one or more ILMI prefixes can be used to generate ATM addresses for CPE as follows:

    1. The CPE retrieves the 13-byte ILMI prefix from the switch.

    2. The CPE prepends its 7-bytes with the 13-byte prefix to form its AESA.

    3. The ILMI running on the switch registers the constructed AESA on the switch.

The default ILMI prefix matches the node prefix, which minimizes the number of prefixes that need to be advertised.

Because the ILMI prefix is used to address CPE and not PNNI nodes, the ILMI prefix is not dependant on the PNNI level, peer group ID, or node prefix. To avoid ambiguity in the network, ILMI prefixes, which are assigned to specific communication ports, should uniquely identify the devices on those ports.

When ILMI is enabled on a UNI port, you can add up to 16 address prefixes for that port. The same ILMI prefix can be assigned to multiple ports. These ILMI prefixes will be advertised by PNNI to enable SVC routing to this node.

Enter the ILMI prefixes you plan to use into the port address worksheet, Table 1-5, which appears at the end of this chapter.

Selecting the SPVC Address Prefix

If you set up Soft Permanent Virtual Connections (SPVCs), the port at each end of the connection must have a globally unique SPVC address. This address is generated by the switch when the connection is defined and consists of the SPVC prefix and an internally generated number that identifies the port.

The default SPVC prefix matches the default node prefix.

When planning the SPVC prefix for your WAN, consider the following:

Enter the SPVC prefix into the nodal address worksheet, Table 1-4, which appears at the end of this chapter.

Selecting the IISP Address Prefix

When you configure an IISP link, you must configure one or more static ATM addresses that define devices at the remote end of the link. If you are configuring an IISP link that leads to a single device, you can configure the link with the ATM address of that device. If the IISP link provides communications to multiple devices, you can configure an IISP summary address to represent all the devices. The summary address is a partial ATM address and represents all destinations for which the most-significant bytes of the ATM address match the summary address.

IISP links are typically used to connect to other WANs or LANs, to isolate high-security parts of a WAN, or to reach devices for which ATM addresses should remain unchanged (for example, server farms).

When planning IISP prefixes for your WAN, consider the following:

Enter the IISP prefix into the port address worksheet, Table 1-5, which appears at the end of this chapter.

Selecting Static Addresses for UNI Ports

If ILMI is not enabled for a UNI port, you can add up to 255 static addresses on that port, if this remains within the maximum addresses per node limit. The addresses are not required to be unique within the node, therefore the same address can be assigned to other UNI ports. These addresses are provided to PNNI to be summarized and advertised.

Enter the static addresses into the port address worksheet, Table 1-5, which appears at the end of this chapter.

Additional Guidelines for Creating an Address Plan

The following are guidelines for creating an address plan:

Configuration Worksheets

Table 1-4 is a worksheet that you can use to write down address planning information that applies to the switches in your WAN. Table 1-5 is another worksheet that you can use to write down address planning information that applies to a port on a single switch. To complete an address plan, you would complete one nodal address worksheet for the WAN and an individual port address worksheet for each switch in the WAN.


Table 1-4: Nodal Address Worksheet
Node Name Address Format PNNI Level Peer Group ID Node Prefix and Summary Addresses ATM Address SPVC Prefix


Table 1-5: Port Address Worksheet
Port ILMI Prefixes IISP Prefixes and Addresses Static Addresses


hometocprevnextglossaryfeedbacksearchhelp