Traps are generated by the AXSM card on various actions. Examples of these actions are adding, deleting, or modifying resources and line failures.
There are three types of traps.
1. Line related traps include traps arising from the SONET, DS3, or ATM lines.
2. Virtual interface related traps are associated with ATM port addition, modification, and deletion.
3. Connection related traps are associated with channel addition, modification, and deletion.
This chapter includes the following sections:
Line related traps include traps created from fault conditions on the SONET, DS3, or ATM lines.
SONET Line related traps are presented in Table 14-1.
![]() |
Note All mandatory trap varbinds are described in Table 14-6. For information about the miscellaneous trap varbinds, see Table 14-7. |
| Trap Name | Trap No. | Specific-Varbinds | Description |
|---|---|---|---|
60101 | ifIndex, ifName | This trap is sent when a SONET line is enabled. | |
60102 | ifIndex, ifName | This trap is sent when a SONET line is disabled. | |
60103 | ifIndex, ifName | This trap is sent when a SONET line goes through any configuration change. | |
60104 | ifIndex, ifName, sonetSectionCurrentStatus, sonetLineCurrentStatus, sonetPathCurrentStatus, ssTraceFailure, cspTraceFailure | This trap is sent when the SONET line goes into alarm. The alarm status bitmap is one of the varbinds of the trap. | |
60105 | ifIndex, ifName, sonetSectionCurrentStatus, sonetLineCurrentStatus, sonetPathCurrentStatus, cssTraceFailure, cspTraceFailure | This trap is sent when a SONET line alarm is cleared. | |
60106 | ifIndex, ifName, sonetSectionCurrentStatus, sonetLineCurrentStatus, sonetPathCurrentStatus | This trap is sent when loopback is enabled on a SONET line. | |
60107 | ifIndex, ifName, sonetSectionCurrentStatus, sonetLineCurrentStatus, sonetPathCurrentStatus | This trap is sent when loopback is disabled on SONET line. | |
60108 | ifIndex, ifName, cwsSectionStatAlarmStatus | This trap is sent when a SONET section layer encounters a statistical alarm. | |
60109 | ifIndex, ifName, cwsLineStatAlarmStatus | This trap is sent when a SONET line layer encounters a statistical alarm. | |
60110 | ifIndex, ifName, cwsPathStatAlarmStatus | This trap is sent when a SONET path layer encounters a statistical alarm. | |
60121 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, ifName | This trap is sent when the APS feature is enabled on a SONET line. | |
60122 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, ifName | This trap is sent when APS feature is disabled on a SONET line. | |
60123 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, csApsLineFailureCode, ifName | This trap is sent when the SONET APS line encountered an abnormal condition. | |
60124 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, csApsLineSwitchReason, ifName | This trap is sent when the SONET line APS switch occurs. | |
60125 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, csApsLineSwitchReason, ifName | This trap is sent when an abnormal condition occurred during the SONET APS switch. | |
60126 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, sonetSectionCurrentStatus, sonetLineCurrentStatus, sonetPathCurrentStatus, ifName | This trap is sent when the SONET APS redundant line is not in service. | |
60127 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, sonetSectionCurrentStatus, sonetLineCurrentStatus, sonetPathCurrentStatus, ifName | This trap is sent when the SONET APS redundant line alarm has been cleared. | |
60128 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, csApsLineFailureCode, ifName | This trap is sent when the SONET APS line failure has been cleared. | |
60129 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, ifName | This trap is sent when the SONET APS configuration parameters changes, for example, if signal degrade parameter changes. | |
60130 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, ifName | This trap is sent when the Sonet APS architecture mode on the two ends of the APS pair is different. This mismatch does not cause an APS failure, the mode on one end is automatically changed to match the other end. | |
60131 | cwTrapIndex, csApsProtectionIndex, csApsActiveLine, ifName | This trap is sent when the Sonet APS architecture mode mismatch is cleared. |
DS3 Line related traps are presented in Table 14-2.
![]() |
Note All mandatory trap varbinds are described inTable 14-6. For a description of each miscellaneous trap varbind, see Table 14-7. |
| Trap Name | Trap No. | Specific-Varbinds | Description |
|---|---|---|---|
60151 | ifIndex, ifName | This trap is sent when a ds3 line is enabled. | |
60152 | ifIndex, ifName | This trap is sent when a ds3 line is disabled. | |
60153 | ifIndex, ifName | This trap is sent when a ds3 line goes through any configuration change. | |
60154 | ifIndex, ifName, dsx3LineStatus | This trap is sent when the ds3 line goes into alarm. The alarm status bitmap is one of the varbinds of the trap. | |
60155 | ifIndex, ifName, dsx3LineStatus | This trap is sent when a ds3 line alarm is cleared. | |
60156 | ifIndex, ifName, dsx3LineStatus | This trap is sent when loopback is enabled on a ds3 line. | |
60157 | ifIndex, ifName, dsx3LineStatus | This trap is sent when loopback is disabled on SONET line. | |
60158 | ifIndex, ifName, cds3LineStatisticalAlarmState | This trap is sent when a ds3 line encounters a statistical alarm. | |
60159 | ifIndex, ifName, cds3PlcpLineAlarmState | This trap is sent when a ds3 Plcp line encounters an alarm. | |
60160 | ifIndex, ifName, cds3PlcpLineAlarmState | This trap is sent when a ds3 Plcp alarm is cleared. | |
60161 | ifIndex, ifName, cds3PlcpLineStatistical | This trap is sent when a ds3 Plcp line encounters a statistical alarm. |
ATM Line Related traps are presented in Table 14-3.
![]() |
Note All mandatory trap varbinds are described in Table 14-6. For a description of each miscellaneous trap varbind, see Table 14-7. |
| Trap Name | Trap No. | Specific-Varbinds | Description |
|---|---|---|---|
60371 | ifIndex, ifName | This trap is sent when physical ATM cell layer loss of cell delineation occured. | |
60372 | ifIndex, ifName | This trap is sent when physical ATM cell layer loss of cell delineation alarm cleared. | |
60373 | ifIndex, ifName | This trap is sent when ATM cell layer configuration changes. |
The Virtual Interface related traps are presented in Table 14-4.
![]() |
Note All mandatory trap varbinds are described inTable 14-6. For a description of each miscellaneous trap varbind, see Table 14-7. |
| Trap Name | Trap No. | Specific-Varbinds | Description |
|---|---|---|---|
60351 | ifIndex, ifName, caviFileId | This trap is sent when an ATM port is deleted. | |
60352 | ifIndex, ifName | This trap is sent when an ATM port is deleted. | |
60353 | ifIndex, ifName | This trap is sent when an ATM port is enabled. | |
60354 | ifIndex, ifName | This trap is sent when an ATM port is disabled. | |
60355 | ifIndex, ifName | This trap is sent when an ATM port configuration changes. | |
60356 | ifIndex, ifName, caviFileId | This trap is sent when the SCT file associated with an ATM port is detected to be missing or corrupted. | |
60357 | ifIndex, ifName | This trap is sent when the ATM port comes out of the failed state, caused because of a corrupted/missing SCT file. | |
60358 | ifIndex, cwmIngressSCTFileId | This trap is sent when the ingress SCT file for a card is detected as missing or corrupted on a switchover. | |
60359 | ifIndex, cwmIngressSCTFileId | Card ingress SCT file alarm cleared. | |
60360 | ifIndex, cwmIngressSCTFileId | Card ingress SCT file id is changed. |
Connection related traps are presented in Table 14-5.
![]() |
Note All mandatory trap varbinds are described inTable 14-6. For a description of each miscellaneous trap varbind, see Table 14-7. |
.
| Trap Name | Trap No. | Specific-Varbinds | Description |
|---|---|---|---|
60301 | ifIndex, ifName, cwaChanLocalVpi, cwaChanLocalVci, cwaChanVpcFlag, cwaChanIdentifier, cwaChanUploadCounter | This trap is sent when a channel gets added. | |
60302 | ifIndex, ifName, cwaChanLocalVpi, cwaChanLocalVci, cwaChanVpcFlag, cwaChanIdentifier, cwaChanUploadCounter | This trap is sent when a channel gets deleted. | |
60303 | ifIndex, ifName, cwaChanLocalVpi, cwaChanLocalVci, cwaChanVpcFlag, cwaChanIdentifier, cwaChanUploadCounter | This trap is sent when a channel gets added or modified. | |
60304 | ifIndex, ifName, cwaChanLocalVpi, cwaChanLocalVci, cwaChanVpcFlag, cwaChanIdentifier, cwaChanAlarmState, cwaChanEgressXmtState, cwaChanEgressRcvState, cwaChanIngressXmtState, cwaChanIngressRcvState | This trap is sent when there is a channel failure. | |
60305 | ifIndex, ifName, cwaChanLocalVpi, cwaChanLocalVci, cwaChanVpcFlag, cwaChanIdentifier, cwaChanUploadCounter | This trap is sent when channel parameters are changed. | |
60306 | none | This trap is sent when many channels are in alarm state. |
Table 14-6 lists the trap variables (varbinds) in each trap generated by the switch. Each of these varbinds, in the order given, is available for each trap generated.
| Varbind | Data Type | Contents |
|---|---|---|
lastSequenceNumber | INTEGER | Contains the sequence number assigned to the trap. This can be used by Network Management System (NMS) applications to implement a Robust Trap Mechanism. |
sysName | OctetString | Contains the node name of the switch. |
entPhysicalContainedIn | INTEGER(0..2147483647) | Contains the chassis number into which the module is connected. |
entPhysicalParentRelPos | INTEGER(-1..2147483647) | Contains the physical slot number to into which the module is connected. |
entPhysicalVendorType | ObjectID | Contains the type of module for which the trap is generated. |
moduleTrapAlarm Severity | INTEGER (enumeration) | Contains the alarm severity of the trap. |
genericTimeStamp | OctetString(1..30) | Contains the time when the trap is generated. |
Table 14-7 lists the other trap varbinds.
![]() |
Note These trap varbinds are not available for all the traps. |
| Varbind | Data Type | Contents |
|---|---|---|
ifIndex | Integer32(1..2147483647) | Specifies a unique value, greater than zero, for each interface. It is recommended that values are assigned starting with one. |
ifName | OctetString(0..255) | Specifies the textual name of the interface. |
sonetSectionCurrentStatus | Integer32(1..6) | Indicates the section status of the interface. |
sonetLineCurrentStatus | Integer32(1..6) | Indicates the line status of the interface. |
sonetPathCurrentStatus | Integer32(1..62) | Indicates the path status of the interface |
dsx3LineStatus | INTEGER(1..4095) | Indicates the line status of the interface. It is used for loopback state information and failure state information. |
csApsProtectionIndex | Integer32(1..2147483647) | Indicates the protection line becomes an active line when an APS switch occurs (APS switch can occur because of a failure on the working line). |
csApsActiveLine | INTEGER(enumeration) | Indicates which line is currently active. |
csApsLineFailureCode | INTEGER(enumeration) | Specifies the SONET APS line failure code, or the failure encountered by the APS line. |
cssTraceFailure | INTEGER(enumeration) | Specifies the value of this object is set to true when the SONET section received trace does not match the |
cspTraceFailure | INTEGER(enumeration) | Sets the value of this object to true when the trace received by the SONET Path does not match the |
csApsLineSwitchReason | INTEGER(enumeration) | When the working line on one end fails, its other end is told to do an APS switch. |
cds3PlcpLineAlarmState | Gauge32 | Specifies a bitmap of the DS3 Line Alarms. A value of zero for this object indicates no alarms. |
cds3PlcpLineStatisticalAlarmState | Gauge32 | Specifies a bitmap of the DS3 PLCP Line Statistical Alarms. |
cds3LineStatisticalAlarmState | Gauge32(0..2147483647) | Specifies a bitmap of the DS3 Line Statistical alarms. |
caviFileId | Gauge32 | Determines the ID of the file that holds module specific configuration parameters for this ATM Virtual interface. |
cwmIngressSCTFileId | Gauge32(0..255) | Defines the file ID of the Service Class Template (SCT) file. |
cwsLineStatAlarmStatus | Gauge32 | Indicates the status of the SONET line. |
cwsPathStatAlarmStatus | Gauge32 | Indicates the status of the interface. The |
cwTrapIndex | Integer32(0..2147483647) | Contains the value that is indexed to any table |
cwaChanLocalVpi | Gauge32(0..4095) | Identifies the internal VPI assigned to a local endpoint by the switch. |
cwaChanLocalVci | Gauge32(0..65535) | Identifies the internal VCI assigned to a local endpoint by the switch. |
cwaChanVpcFlag | INTEGER (enumeration) | Identifies whether or not there is a VP/VC endpoint. |
cwaChanIdentifier | Gauge32 | Represents a RESOURCE at the switch that has been assigned for this connection (identified by |
cwaChanUploadCounter | Gauge32 | Tracks the number of configuration changes that happen on a |
cwaChanAlarmState | INTEGER (enumeration) | Defines the alarms associated with an endpoint. |
cwaChanEgressXmtState | INTEGER | Specifies the state of the transmit portion of the endpoint in the egress direction. |
cwaChanEgressRcvState | INTEGER | Specifies the state of the receive portion of the endpoint in the egress direction. |
cwaChanIngressXmtState | INTEGER | Specifies the state of the transmit portion of the endpoint in the ingress direction. |
cwaChanIngressRcvState | INTEGER | Specifies the state of the receive portion of the endpoint in the ingress direction. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Sep 15 11:00:21 PDT 2000