Table 3-1: PXM45 Traps and Alarms
Trap Name Trap No. Description

cwChassisIntegratedAlarm

60001

Sent when the integrated alarm for the shelf is changed.

cwUserLogin

60002

Sent when a user logs in.

cwUserLogout

60003

Sent when a user logs out.

cwShelfRestart

60004

Sent when the shelf is rebooted.

cwNodeNameChange

60006

Sent when the node name is modified.

cwIpAddressChange

60007

Sent when the IP Address (Ethernet IP, ATM IP) is modified.

cwControllerAdd

60008

Sent when a VSI Controller is added.

cwControllerDelete

60009

Sent when a VSI Controller is deleted.

cwChassisTemperatureNormal

60026

Sent when the temperature is back to normal.

cwChassisTemperatureAboveNormal

60027

Sent when the temperature is above the threshold.

cwChassisDclevelNormal

60028

Sent when the DC Level is back to normal.

cwChassisDclevelBelowNormal

60029

Sent when the DC level is below the normal range.

cwChassisPowersupplyNormal

60030

Sent when the power supply is back to normal voltage.

cwChassisPowersupplyFailed

60031

Sent when the power supply is failed.

cwChassisFanrpmNormal

60032

Sent when the fan rpm is back to normal.

cwChassisFanrpmBelowNormal

60033

Sent when the fan rpm is below the normal value.

cwModuleInserted

60051

Sent when the Front Module is plugged into a slot. This trap is sent for Processor Module as well as Service Modules.

cwModuleRemoved

60052

Sent when the Front Module is removed from the slot.This trap is sent for Processor Module and service modules.

cwModuleMismatch

60053

Sent when the Front Module is plugged into a slot which was configured with some other module earlier.

cwModuleActive

60055

Sent when a module becomes active. This may be a due to switch over or a failed card becomes active.

cwModuleStandby

60056

Sent when a module becomes standby due to switch over.

cwModuleFailed

60057

Sent when a module goes to a failed state.

cwLineModuleInserted

60058

Sent when a line module (back card ) is inserted.

cwLineModuleRemoved

60059

Sent when a line module (back card ) is removed.

cwLineModuleMismatch

60060

Sent when a incompatible line module ( back card ) is inserted into the front module or inserted line module is not same as the one configured earlier.

cwCoreCardSwitch

60078

Sent when there is a switch over for core card set.

cwRedundancyAdd

60079

Sent when a redundancy is added for a module pair

cwRedundancyDelete

60080

Sent when a module pair is deleted from the redundancy configuration.

cwRedundancyActivate

60081

Sent when a secondary module becomes active. This is due to switch over.

cwRedundancyRevert

60082

Sent when a primary module becomes active.This is due to switch over.

cwBulkFileCreationStarted

60901

Sent when the bulk file creation is started.

cwBulkFileCreationDone

60902

Sent when the bulk file creation is done.

cwBulkFileCreationAborted

60903

Sent when the bulk file creation is aborted.

cwBulkNoTaskAvailable

60904

Sent when the bulk file creation failed due to non availability of task.

cwBulkFileCreationFailed

60905

Sent when the bulk file creation is failed for reasons other than the non-availability of the task.