Traps and alarms are sent by the PXM45 card on various actions. Examples of these actions are adding, deleting, or modifying resources and line failures.
Table 3-1 describes the various PXM45 traps and alarms.
| Trap Name | Trap No. | Description |
|---|---|---|
60001 | Sent when the integrated alarm for the shelf is changed. | |
60002 | Sent when a user logs in. | |
60003 | Sent when a user logs out. | |
60004 | Sent when the shelf is rebooted. | |
60006 | Sent when the node name is modified. | |
60007 | Sent when the IP Address (Ethernet IP, ATM IP) is modified. | |
60008 | Sent when a VSI Controller is added. | |
60009 | Sent when a VSI Controller is deleted. | |
60026 | Sent when the temperature is back to normal. | |
60027 | Sent when the temperature is above the threshold. | |
60028 | Sent when the DC Level is back to normal. | |
60029 | Sent when the DC level is below the normal range. | |
60030 | Sent when the power supply is back to normal voltage. | |
60031 | Sent when the power supply is failed. | |
60032 | Sent when the fan rpm is back to normal. | |
60033 | Sent when the fan rpm is below the normal value. | |
60051 | Sent when the Front Module is plugged into a slot. This trap is sent for Processor Module as well as Service Modules. | |
60052 | Sent when the Front Module is removed from the slot.This trap is sent for Processor Module and service modules. | |
60053 | Sent when the Front Module is plugged into a slot which was configured with some other module earlier. | |
60055 | Sent when a module becomes active. This may be a due to switch over or a failed card becomes active. | |
60056 | Sent when a module becomes standby due to switch over. | |
60057 | Sent when a module goes to a failed state. | |
60058 | Sent when a line module (back card ) is inserted. | |
60059 | Sent when a line module (back card ) is removed. | |
60060 | Sent when a incompatible line module ( back card ) is inserted into the front module or inserted line module is not same as the one configured earlier. | |
60078 | Sent when there is a switch over for core card set. | |
60079 | Sent when a redundancy is added for a module pair | |
60080 | Sent when a module pair is deleted from the redundancy configuration. | |
60081 | Sent when a secondary module becomes active. This is due to switch over. | |
60082 | Sent when a primary module becomes active.This is due to switch over. | |
60901 | Sent when the bulk file creation is started. | |
60902 | Sent when the bulk file creation is done. | |
60903 | Sent when the bulk file creation is aborted. | |
60904 | Sent when the bulk file creation failed due to non availability of task. | |
60905 | Sent when the bulk file creation is failed for reasons other than the non-availability of the task. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()