System management screens configure the overall parameters of an Cisco MGX 8260 node and define its interactions with other nodes and servers.
Before you can configure the Cisco MGX 8260, you must log on as a user with the privilege to change system parameters. You need SuperUser privileges to change most system-level settings.
To log on, follow these steps:
Step 2 Connect to the MGX 8260 HTTP server using the conventional http:// notation. You need to know the host name or IP address for the desired MGX 8260 node.
Step 3 The logon screen is displayed.
Step 4 In the User Id field, type your user name. On a new system, use SuperUser.
Step 5 In the Password field, type your password. On a new system, use cisco or the new password you assigned to this account.
The Cisco MGX 8260 displays the chassis view (see Figure 2-1).

Step 6 From the Navigation pane on the left, select the operation you want to perform. To set node parameters click Node and then click a submenu item.
See the following sections for configuration tasks for nodes:
To view or change general system parameters, follow these steps:
Step 2 Click System.
Three System Configuration forms opens.

Step 3 In the Rack, Node, and Backplane section of the Configuration Settings form, click Set.
The System Configuration Setting screen opens:

Step 4 Enter the rack and node information in the System Configuration Settings form.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
Step 5 Click Modify, and then go back to the Configuration Setting form.

Step 6 In the DS1 Line Interface Mode section, click Set.
The System Ds1 Line Interface Mode Setting screen appears:

Step 7 Specify the interface mode for the chassis.
Parameter | Description |
|---|---|
|
|
|
|
![]() |
Warning Changing the interface mode interrupts service. Perform this operation during light traffic periods or during a pre-arranged maintenance window. |
Step 8 Click Modify.
After changing the interface mode, the node automatically resets.
Step 9 Login, and repeat steps 1 and 2.
Step 10 In the System section of the Configuration Setting screen, click Gateway Control Protocol.
The System Gateway Control Protocol Setting screen appears:

Step 11 Specify the communication protocol for call control.
Parameter | Description |
|---|---|
|
|
|
|
![]() |
Warning Changing this protocol mode interrupts service. Perform this operation during light traffic periods or in a pre-arranged maintenance window. |
Step 12 Click Modify. The system applies the changes.
After changing the protocol for the gateway, the node automatically resets.
To view or change system group parameters, follow these steps:
Step 2 Click System.
The three System Configuration forms open, one of which is the System Group Setting form used in this procedure.

Step 3 Click Set on the System Group Setting form.
The System Group Setting form is redisplayed with several text boxes.

Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Step 4 Enter new values.
Step 5 Click Modify. The system applies the changes.
Step 6 Go back to the System Configuration forms, and go to the next procedure.
To view or change the time, follow these steps:
Step 2 Click System.
The three System Configuration forms open, one of which is the Time Setting form used in this procedure.

Step 3 Click Set on the Time Setting form.
The System Time Setting form is displayed.

Parameter | Description |
|---|---|
|
|
|
|
|
|
| 1GMT = Greenwich Mean Time |
| Zone | Value | Zone | Value | |
|---|---|---|---|---|
gmtplus12 | 1 |
| gmtminus01 | 14 |
gmtplus11 | 2 | gmtminus02 | 15 | |
gmtplus10 | 3 | gmtminus03 | 16 | |
gmtplus09 | 4 | gmtminus04 | 17 | |
gmtplus08 | 5 | est | 18 | |
gmtplus07 | 6 | cst | 19 | |
gmtplus06 | 7 | pdt | 20 | |
gmtplus05 | 8 | pst | 21 | |
gmtplus04 | 9 | gmtminus9 | 22 | |
gmtplus03 | 10 | gmtminus10 | 23 | |
gmtplus02 | 11 | gmtminus11 | 24 | |
gmtplus01 | 12 | gmtminus12 | 25 | |
gmt | 13 |
|
|
|
Step 4 Enter new values.
Step 5 Click Modify. The system applies the changes.
To view the HTML version, follow these steps:
Step 2 Click System.
The three System Configuration forms open, one of which is the HTML form.
Step 3 View the HTML version number.
You configure the MGX 8260 management interface for local or remote operation by setting the appropriate IP addresses and management paths. Assign management IP addresses for each of the following management interfaces that you plan to use:
![]() |
Note If you change the IP address of the port the WebViewer is using, you will interrupt the session. |
To view and change management interface parameters, follow these steps:
Step 2 Click Management IP.
The Management IP Settings form opens, displaying existing settings.

Step 3 Interpret the information as follows:
Displayed Information | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
Step 4 Click Set to modify a management IP setting.
A Management Ethernet IP Setting form, such as the following one, or a similar form for setting the In-Band IP appears.

Step 5 Enter new values.
Step 6 Click Modify. The system applies the changes.
This section describes the process of configuring IP routes for the management interfaces.
To view all IP routes, follow these steps:
Step 2 Click IP Route Setup.
The IP Route screen opens:

Step 3 To view detail information about a route, and click the I icon on the desired row.
The IP Route Information form opens:

Step 4 Interpret the information as follows:
| Displayed Information | Description |
|---|---|
Destination | The destination IP address. Destination 0.0.0.0 is the default route. |
Gateway | The gateway, or next hop, for the route. This can be the address of the Ethernet or in-band management ports. |
IF | The interface identifier: 1Primary Ethernet port 2Secondary Ethernet port 3In-band path |
Mask | The subnet for the route. |
Type | The type of route, such as direct or indirect. |
Protocol | The protocol type, such as local or other. |
Age | The age of the route is seconds. |
Mib Information | The version of the MIB associated with the interface. |
Metric 1-5 | The primary and alternate route metrics. These are specific to the protocol type, but -1 indicates not used. |
To add a static route, follow these steps:
The Add IP Route screen opens:

Step 2 Enter the IP Address of the destination.
![]() |
Note Destination 0.0.0.0 is the default route. |
Step 3 Enter the mask.
Step 4 Click Add.
The system adds the IP route to the routing table.
To delete an IP route, follow these steps:
Step 2 Click IP Route Setup.
The IP Route screen opens:

Step 3 Locate the IP Route that you want to delete in the list of routes, and click the - icon on that row.
Step 4 Click Delete.
The IP route is deleted the network.
To view information about an IP route, follow these steps:
Step 2 Click IP Route Setup.
The IP Route screen opens:

The MGX 8260 clock module has three synchronization options:
You assign one clock source as the primary source and another as the secondary source. When using the line clock source, specify both the line and slot associated with the source.
During normal operation, the primary clock is the active source and the secondary clock is the backup source. If the active source fails, the Cisco MGX 8260 switches to the backup clock and reports an alarm. You can also switch to the backup source manually. This section explains how to set primary and secondary clocks and view clock status.
The clock parameters include:
To view or change clock source information, follow these steps:
Step 2 Click Clock Source.
The Clock Source screen opens.

Step 3 Interpret clock settings as follows:
Setting | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
![]() |
Note The selected clock source may not be the active clock source if the selected clock fails. |
Step 4 Click Set to modify the clock source.
The Primary Clock Source Setting form, or the corresponding form for setting the secondary clock, appears.

Step 5 Specify new settings, using the following table as a guide:
Source | Slot | Line | ClkSrcType | ClkSrcCardType |
|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1Optional settings are ignored, but they must be valid entries. |
Step 6 Click Modify.
The system updates the clock settings.
You can force the system to switch between the primary and secondary clock. During normal operation, the current clock is the primary clock. Typically you switch clocks to restore the primary clock source after an automatic switchover to the secondary clock.To switch to the secondary clock, follow these steps:
Step 2 Click Clock Source.
The Clock Source screen opens.
Step 3 On the Clock Source screen, click Switch Clock Source and confirm your action.
When managing the Cisco MGX 8260 from a SNMP manager, security is enforced with password-like community strings. SNMP communities are groupings of workstations and servers (or gateways) that can manage the Cisco MGX 8260. Community strings are important when managing the Cisco MGX 8260 from a Network Management System, like HP Openview. You can configure up to 15 community strings.
To view all community strings, follow these steps:
Step 2 Click SNMP.
Step 3 From the SNMP options, click Community String.
The Community String screen opens.

Step 4 Interpret the table as follows:
Table Entry | Description |
|---|---|
|
|
|
|
|
|
To add a community string, follow these steps:
Step 2 Click SNMP.
Step 3 From the SNMP options, click Community String.
The Community String screen opens.
Step 4 Click the + icon.
The Add Community String form opens.

Step 5 Enter the following parameters:
Parameter | Description |
|---|---|
|
|
|
|
|
|
Step 6 Click the Add button.
The system adds the community string.
To delete a community string, follow these steps:
Step 2 Click SNMP.
Step 3 From the SNMP options, click Community String.
The Community String screen opens.
Step 4 Click the - icon of the community string you want to delete and confirm your action.
The system deletes the community string.
To view trap registrations, follow these steps:
Step 2 Click Trap Registration.
The Trap Registration screen opens.

Step 3 Interpret the table as follows:
Table Entry | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
| Trap | Description |
|---|---|
Severity | Major (trap severity selection) |
Severity | Minor (trap severity selection) |
Severity | Information (trap severity selection) |
1000-1099 | Shelf |
1100-1199 | Card |
1200-1299 | SNMP |
1300-1399 | Dsx1 Line |
1400-1499 | Dsx3 Line |
1500-1599 | Sonet Line |
1600-1699 | Ether Line |
1700-1799 | Voice Port |
N/A | Ether Channel |
N/A | Voice Channel |
1800-1899 | EMM |
1900-1999 | Clock |
2000-2099 | DSP |
2100-2199 | DMCMAP |
2200-2299 | ISDN |
2300-2399 | MGCP |
2400-2499 | Backhaul Session |
To add SNMP trap subscriptions, follow these steps:
Step 2 Click Trap Registration.
The Trap Registration screen opens.
Step 3 Click the + icon.
The Add Trap Registration form opens.


Step 4 Enter the trap parameters:
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
Step 5 Click Add.
The system registers the traps for the specified manager.
To change SNMP trap subscriptions, follow these steps:
Step 2 Click Trap Registration.
The Trap Registration screen opens.
Step 3 Click the i icon.
The Modify Trap Registration form opens.


Step 4 Modify the trap parameters:
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
Step 5 Click Modify.
The system modifies the trap registration for the specified manager.
To delete SNMP trap registrations, follow these steps:
Step 2 Click Trap Registration.
The Trap Registration screen opens.
Step 3 Click the - icon of the trap registration you want to delete and confirm your action.
The system deletes the registration.
The Cisco MGX 8260 enforces security with user accounts and access levels. Users must log onto the Cisco MGX 8260 before performing any task, and authenticated users can perform only those tasks permitted by their access level. The Cisco MGX 8260 supports up to 20 user accounts, each with access privileges ranging from full control to guest.
| Access Level | Account type | Command groups |
|---|---|---|
1 | SuperUser | Access all features |
2 | Administrator | Configure and view all features except user profiles and community strings |
3 | Provisioning | Configure and view system, port, lines, end points, and connections |
4 | Maintenance | Access selected level 3 commands |
5 | Operator | View system, port, lines, end points, and connections |
6 | Guest | View system, common lines and ports |
A new system has a default SuperUser account. To prohibit unauthorized access to the equipment, replace the default account with a unique one and create new accounts for other personnel.
To view all user accounts, follow these steps:
Step 2 Click User Profile.
The User Profile screen opens.

Step 3 Interpret the table as follows:
Table Entry | Description |
|---|---|
|
|
|
|
|
|
To add a new user, follow these steps:
Step 2 On the Navigation pane, click Node.
Step 3 Click User Profile.
The User Profile screen opens.
Step 4 On the User Profile screen, click the + icon.
The Add New User Profile form opens.

Step 5 Enter the new user parameters:
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
Step 6 Click Add.
The system adds the new user account.
Step 7 Repeat these steps for other users you want to authorize.
To change a user account, follow these steps:
Step 2 On the Navigation pane, click Node.
Step 3 Click User Profile.
The User Profile screen opens.
Step 4 On the User Profile screen, click the i icon for the account you want to modify.
The Modify User Profile form opens.

Step 5 Change the user parameters:
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
Step 6 Click Modify.
The system applies the changes to the user account.
You can always change your own password, but you need SuperUser privilege to change the password of others.
To change a password, follow these steps:
The New Password Setting form opens.

Step 2 Enter the following parameters:
Parameters | Description |
|---|---|
|
|
|
|
|
|
|
|
Step 3 Click Modify Password. The system changes the account password.
To delete a user, follow these steps:
Step 2 On the Navigation pane, click Node.
Step 3 Click User Profile.
The User Profile screen opens.
Step 4 On the User Profile screen, click the - icon on the row of the user you want to delete and then confirm your action.
The system removes the user from the database. Level 1 users return to their original SuperUser account.
To display a list of users who are logged in with information about them and their login session, follow these steps:
Step 2 Click Login Session.
The User Session screen opens.

Step 3 Interpret the information as follows:
Table Entry | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To display duration information about announcement files, follow these steps:
Step 2 Click Announcement File.
Step 3 Click Duration.
The Duration Information of Announcement Files screen opens, showing the maximum, current, and available duration of the announcement files.

To activate, deactivate, or remove an announcement file, follow these steps:
Step 2 Click Announcement File.
Step 3 Click File.
The Announcement File screen opens, showing information about the announcement files.

Step 4 Interpret the information about the announcement files as follows:
Table Entry | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
Step 5 Click the +, -, or R icon on the line with the announcement file you want to activate, deactivate, or remove, respectively.
The system asks you to confirm you action.
Step 6 Click Activate, Deactivate, or Remove.
A message is displayed saying that the announcement file has been successfully activated, deactivated, or removed.
Step 7 Click Display All Announcement Files to return to the Announcement File screen.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Oct 2 23:11:35 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.