Traffic Management

Traffic Management

MGX 8250 traffic management features are designed to minimize congestion while maximizing the efficiency of traffic routing. Parameters such as minimum cell rate (MCR), committed information rate (CIR), committed port rate (CPR), and committed delivery rate (CDR) provide deterministic performance and fairness for each VC and for each service class.

The MGX 8250 platform reserves queues specifically for IP traffic, and uses queuing and prioritizing algorithms to enhance the standard CoS offerings, which include:

Traffic Management Functions

On the MGX 8250, the traffic management functions are performed in two separate locations:

    1. In service modules (including the virtual service module that handles the PXM 1 broadband interfaces)

  The following traffic management functions are performed on service modules and the VSM:

    2. In the switch fabric's queue engine on PXM 1

  The queue engine (QE) ASIC provides the traffic management functions related to VC queues, QoS queues, and interface queues. This is done for both directions of traffic. The PXM 1 card can have up to four physical lines. The user can split the line resources into multiple logical ports up to a maximum of 32. The switching fabric maps each of these logical ports defined on the PXM 1 lines to what is termed a virtual interface (VI). The switching fabric also maps each service module slot to a virtual interface.
  Figure 7-1 reflects functional flow of data passing through the PXM 1 switch fabric and daughter card.

Figure 7-1: PXM Switch Fabric (Redraw Illustration)


  Ingress traffic is defined as data flowing toward the switch fabric. Ingress data can come from either the service modules through the backplane or the PXM 1 uplink back card.
  Egress traffic is defined as data flowing away from the switch fabric.
  Ingress data from service modules arrives at the PXM 1 via the cell bus and hits the switch fabric, where the VC and Qbin queueing occurs. The destination of this traffic defines which VI queue it will be placed into. Ingress data from the PXM 1 will first be channeled through the uplink daughter card where policing will occur. The uplink ingress data will then pass through the switching fabric and the same VC, Qbin, and VI queuing will occur.

Figure 7-2 show in detail the general traffic flow. Figure 7-3 shows the Switch Module to Switch Fabrication arbitration. Figure 7-4 shows Egress Traffic Management.


Figure 7-2: Ingress Traffic Management



Figure 7-3: Service Module to Switch Fabric Arbitration



Figure 7-4:
Egress Traffic Management


Configurable Traffic Parameters

There are four groups of traffic management parameters that are configured for each connection:

    1. Policing Parameters are applied in service modules and the VSM (virtual service module). These are effective for the ingress traffic coming into the service modules/VSM. Following are examples:

    pcr
    scr
    ibs
    mbs
    ingrUpcFGCRAEnable
    cdvt
    scrPolicingEnable
    cir
    bc
    be
    ibs
    None used
    pcr
    scr
    cdvt
    mbs
    scrPolicingEnable

    2. The second group of parameters controls the VC queue properties in the service modules. These parameters also apply to the ingress traffic only. Please note that this set of parameters does not apply to VSM since it does not have VC queuing capability. Examples of parameters include:

    ingressQDepth
    ingressClpHiThresh
    ingressClpLoThresh
    ingressEFCITHresh
    Discard option
    ingressQDepth
    ingressQDEThresh
    ingressQECNThresh
    None used
    None used

    3. The third set of parameters controls the properties of VC queues and QoS queues in the PXM 1. These parameters are applicable to both directions of traffic. These parameters are not set on a per-connection basis. Rather, they are controlled/managed through customer-configurable service templates (not currently implemented). The concept of a service template allows customers to define a set of service classes by fine-tuning the VC queue and QoS queue parameters. These templates are configured once in the system. At the time of connection, provisioning each connection is associated with one of the classes through the "service type" MIB object. The queue parameters configured for that service type are then applied to that connection in the QE. Thus, a finite sets of queue parameter combinations are defined in the beginning. The user can choose one predefined set of parameter combinations for each connection to be provisioned.

Currently, the service templates are not implemented in the MGX 8250 platform. The VC queue parameters are currently defaulted as follows for all connections:

    4. The fourth set of parameters selects the egress service queue type for the traffic leaving the system through service modules. This does not apply to VSM because it does not have any egress service queues. Examples of these parameters include:

  None used

Connection Admission Control

Connection Admission Control (CAC) is performed on-port in the ingress and egress directions. Port overbooking is optionally supported on both the FRSM and the AUSM/B. The CAC override function is configurable on a per-connection basis.

For AUSM/B, PXM 1, and FRSM, CAC admits a new connection if the following holds true:

For CAC on FRSM-8T1E1

Ingress (when CAC override is off or CAC is enabled):

Egress:

When CAC overide is ON or CAC is disabled, the load is still cumulated on the port for a channel, but it is always admitted if CIR/chanEgrSrvRate is less than port speed.

For CAC on AUSM/B-8T1E1

For the ingress rate, ingrUpcPCR01 is used for CBR/VBR & UBR, foresightMIR is used for ABR. For the egress side, the rate used is ausmChanEgrSrvRate.

CAC Algorithms:

Ingress side:

Egress side:

For the rest of the cases, CAC passes.

Policing

The edge concentrator complies with the UPC policing standards as defined by the ATM Forum UNI 3.1 specifications. The following are the traffic descriptors configurable on a per-connection basis:

Configuring Traffic Descriptors

The AUSM/B modules—depending on the type of connection—different connection's bandwidth control parameters can be defined. For CBR and UBR connections, PCR and CDVT are specified. For VBR and ABR connections, and PCR and CDVT, SCR and BT are specified. Table 7-1shows the different parameters that can be defined during connection setup. It also indicates that UPC can be enabled/disabled on a per connection basis.


Table 7-1: Connection Parameters
Parameter Description

<chan_num>

Channel number

<enable>

Enable/disable for UPC: 1 = disable, 2 = enable

<pcr[0+1]>

Peak cell rate [0+1]

<cdvt[0+1]>

Cell delay variation [0+1]

<pcr[0]>

Peak cell rate [0]

<cdvt[0]>

Cell Delay Variation [0]

<scr>

Sustained cell rate

<scr_police>

Specifies the type of scr policing: 1 = CLP[0] Cells,2 = CLP[0+1] Cells,
and 3 = no SCR policing

<mbs>

Maximum burst size

<clp_tag>

Enable for CLP tagging: 1 = disable, 2 = enable

The pcr [0], cdvt [0] and clp_tag parameters shown above do not apply for the PXM 1 UNI ports. On the FRSM modules, the Frame Relay policing parameters are configurable per channel as shown in Table 7-2.


Table 7-2: Frame Relay Policing Parameters
Parameter Description

<chan_num>

Channel number

<cir>

Committed information rate

<bc>

Committed burst

<be>

Excess burst

<ibs>

Initial burst size

<de tag>

Enable or disable DE (Discard Eligible) bit tagging on ingress frames

<egress service rate>

Specify the rate that the channel will be serviced at egress

Policing Using ATM Forum Standards

The MGX 8250 UPC function can be configured to police incoming traffic streams on any combination of PCR (0), PCR (0+1), SCR, CDVT, and BT. For broadband interfaces, the policing is done by the RCMP chip on the trunk card. The RCMP supports two approximations to the GCRA algorithm for each connection. Per-VC policing is done to adhere to parameters negotiated at connection setup. For CBR and UBR connections, PCR and CDVT are specified. For VBR and ABR connections, in addition to PCR and CDVT, SCR and BT are specified. Policing can be done on a programmable combination of cell types: user cells, OAM cells, high or low-priority cells, or RM cells.

The MGX 8250 provides a selective cell-discard function (distinguishing high-priority cells over low-priority cells) that can be utilized for all QoS classes except those associated with the constant bit rate (CBR) service class.

During connection setup, the action taken on a non-conforming cell can be programmed on a per-VC basis:

For CBR and UBR connections, only one policing instance (GCRA-1) is needed to check for PCR and CDVT conformance. For VBR and ABR connections, one policing instance (GCRA-1) is needed to check for PCR, CDVT conformance, and another instance (GCRA-2) for SCR, BT conformance. Frame discard features are supported in the queue engine.

Policing features supported by the different service modules are summarized as described in Table 7-3.


Table 7-3: Supported Policing Features
Service Module Description

Frame Service Module (FRSM)

Polices every valid cell received from the T1/E1 ports

Policing function is based on CIR, Be, Bc, IBS

ATM UNI Service Module (AUSM/B)

For CBR connections, traffic is policed using a single policing instance GCRA-1 that checks for PCR and CDVT conformance

For VBR and ABR connections, traffic is policed using a dual policing instance: GCRA-1 that checks for PCR, CDVT conformance, and GCRA-2 that checks for SCR, BT conformance

Partial Packet Discard is implemented in the policing function

Early Packet Discard is done on Per VC Qs

Policing Provisioned Point-to-Point Virtual Circuits

The granularity of the PCR is defined by the sampling rate of the policing algorithm. Table 7-4 shows the minimum PCR, and maximum CDVT parameters for the available sampling rates on PXM1.


Table 7-4: Policing Rates
Sampling Rate 20 ns

PCR min (CPS)

48

CDVT max (sec)

5

Service Module Policing Function

Frame Service Module (FRSM)

The policing function for the FRSM cards is based on a dual leaky bucket operation. The first bucket checks for compliance with the burst Bc, and the second bucket checks for compliance with the burst Be. The policing function in the FRSM measures the incoming traffic average rate over a period "T." It then decides if the traffic should be:

The policing mechanism differs slightly between the lower speed FRSM cards (FRSM-8T1/8E1/8-T1-C/8-E1-C/HS1/B) and the higher speed FRSM cards (FRSM-HS2/2CT3/2T3E3).

The overall dual leaky bucket algorithm is used for both types of cards, but there are a few differences regarding limits, the credit scheme, and the IBS function as described below:

For the lower speed FRSMs, if the amount of credit accumulated is less than the IBS value (which is user configurable), then the frame was marked for a separate IBS queue.

Figure 7-5 shows the ingress cell flow on the FRSMs.


Figure 7-5: Ingress Cell Flow


For FRSM modules, the F-GCRA feature is not available at the UPC policing point.

ATM Service Module (AUSM/B)

The UPC in AUSM/B can be configured to run either a frame-based generic cell rate algorithm (FGCRA) or the GCRA defined in ATM UNI3.0. In case of FGCRA, at the arrival of the first cell of the frame, the bucket depth is compared with a limit parameter (example: L1). If the first cell is noncompliant, then all the remaining cells in the frame will be treated as noncompliant. If the first cell is compliant, then remaining cells will be compliant if the depth of the bucket upon cell arrival is less than or equal to a limit parameter (example: L2).

Once the cell has passed through UPC, it will be queued onto the ingress queue after the following checks:

    1. The queue is full (the cell is then discarded)

    2. The CLP High Threshold is exceeded (the CLP set cells will therefore be discarded)

    3. The CLP hysteresis is set (once cells reach CLP threshold, they will be dropped until CLP low threshold is reached)

    4. EPD/PPD discard is set (if the first cell of the frame exceeds EPD threshold, then all cells of that frame are discarded)

In addition to the FGCRA algorithms provided by the AUSM/B, there is an EPD/PPD feature available in QE. This is enabled on a per-connection basis. Figure 7-6 shows the ingress flow on the AUSM/Bs.


Figure 7-6: Ingress Flow on an AUSM/B


Figure 7-7 and Figure 7-8 show the policing for the different types of traffic.


Figure 7-7: CBR Traffic Policing



Figure 7-8:
VBR Traffic Policing


Table 7-5 summarizes the UPC actions based on the type of policing selected for VBR traffic.


Table 7-5: UPC Actions Based on VBR Traffic Policing
SCR Policing Type Cells Policed on Second Bucket CLP Tagging Value Results of Noncompliance

1

CLP = 0 only

Disable

Discarded

1

CLP = 0 only

Enable

Set CLP = 1

2

All cells

Disable

Discarded

2

All cells

Enable

Set CLP = 1

3

No cells

-

All cells passed to network

ABR Traffic Policing


Figure 7-9: ABR Traffic Policing



Figure 7-10: UBR Traffic Policing


Processor Switch Module (PXM 1)

The broadband line daughter card polices data from broadband ports configured as user ports. UPC is performed on a per-channel basis. Figure 7-11, Figure 7-12, and Figure 7-13 show the policing for the different types of traffic.


Figure 7-11: CBR Traffic Policing



Figure 7-12:
VBR Traffic Policing



Figure 7-13:
ABR Traffic Policing



Figure 7-14: UBR Traffic Policing


Table 7-6 summarizes the UPC actions based on the type of policing selected for VBR traffic.


Table 7-6: UPC Actions Based on VBR Traffic Policing
Conn. Type Policing Type ATMF TM4.0 Conformance Definition PCR Flow (1st leaky bucket) SCR Flow (2nd leaky bucket) CLP Tagging (SCR noncompliant)

VBR

1

VBR.1

CLP(0+1)

CLP(0+1)

No

VBR

2

VBR.2

CLP(0+1)

CLP(0)

No

VBR

3

VBR.3

CLP(0+1)

CLP(0)

Yes

VBR

4

CLP(0+1)

Off

N/A

VBR

5

Off

Off

N/A

Table 7-7 summarizes the UPC actions based on the type of policing selected for UBR traffic:

QoS and Buffer Architecture


Table 7-7: UPC Actions Based on UBR Traffic Policing
Conn. Type Policing Type ATMF TM 4.0 Conformance Definition PCR Flow (1st leaky bucket) SCR Flow (2nd leaky bucket) CLP Tagging (SCR noncompliant)

UBR

4

UBR.1

CLP(0+1)

N/A

N/A

UBR

3

UBR.2

CLP(0+1)

CLP(0)

Yes

UBR

5

Off

Off

N/A

The QoS classes provisioned for on a per-connection basis in 8250 modules are as follows:

The MGX 8250 can isolate the different QoS traffic streams within each logical interface connecting to the switch fabric so that it has a separate set of Qbins. Each set consists of a Qbin for each distinct CoS (CBR, VBR-RT, VBR-NRT, standard ABR, ForeSight ABR, UBR). All the cells on all connections of a given CoS are queued into the Qbin for that CoS. The servicing of the Qbins of each interface is based on the minimal service rate and the relative priority between all CoSs.

The MGX 8250 provides up to 16 QoS queues for each virtual interface.

In order to provide additional granularity over the six classes of Quality of Service Qbins used (CBR, nt_VBR, nrt_VBR, ABR_std, ABR_fst, UBR), the switch fabric on the MGX 8250 allows per-VC setting of VC queue (VCQ) parameters based on QoS descriptors in the future. At present VCQ parameters are defaulted based on service type. The MGX 8250 switch fabric has egress per-VC queues feeding class of service (CoS) queues. The per-VC queues have a set of parameters that can be set in order to define which per VC queues (VCQ) get admitted into the CoS queues first. The configurable VCQ parameters are:

Each service module has cell-buffering capability in the ingress direction to the network. There is also buffering at each interface in egress direction.

Frame Service Module (FRSM)

For the FRSM cards the buffer size is as follows:

Ingress Queuing

All conforming frames in a VC queue are serviced based on the VC's configured CIR. The CIR measurement is done by monitoring committed burst, Bc, during a burst duration, Tc. If more than Bc bytes of traffic are received within the Tc interval, the arrival rate is considered to exceed CIR.

The per-VC queuing differs slightly for the high-speed FRSM cards and the lower speed FRSM cards.

High-speed FRSM Cards

This group includes the FRSM-HS2, FRSM-2CT3, and the FRSM-2T3E3. In the ingress direction, there are five different classes of service, CBR, rt-VBR, nrt-VBR, ABR, and UBR.

Lower Speed FRSM Cards

This group includes the FRSM-8T1/8E1/8T1-C/8E1-C/HS1/B cards. In the ingress direction, different classes of service are not supported for per-VC queuing.

Figure 7-15 shows the per-VC queuing on the FRSM cards.


Figure 7-15: Per-VC Queuing on FRSM Cards


Egress Queuing

ATM-like CoS queues have been introduced on the high-speed FRSM cards (FRSM-HS2/2CT3/2T3E3). There are four data queues:

The lower speed FRSM cards (FRSM-8T1/8E1/8T1-C/8E1-C/HS1/B) have no ATM-like CoS egress queuing mechanism. These cards have two levels of priority for data traffic: a high-priority queue and a low-priority queue. Queue is determined based upon connection type. In case of two queues, high-priority and VBR-RT connections are assigned to a high-priority queue, and VBR-NRT, ABR, and UBR are assigned to a low-priority queue.

For every N times that the high-priority queue is serviced, the low-priority queue is serviced once. N is a user-configurable parameter. There is also a separate queue for LMI traffic.

For the high-speed FRSM cards (FRSM-HS2/2CT3/2TE3) in the egress direction, there is multiple-priority-level queuing per logical port. Four data egress queues and one LMI queue are maintained. There are four egress data queues:

The egress CoS mechanism implemented in the high-speed cards is based on an ATM OptiClass algorithm (algorithm 3). This is the first time that an ATM-like CoS has been introduced in a frame-service module. It is implemented in two stages:

In the second stage described above, the service algorithm uses a weighted-fair-queue mechanism to guarantee different classes of service. The "weight" is determined by the number of credits (or bandwidth increments) accumulated. The credits (or bandwidth increments) are automatically computed from the CIR/MIR of all connections mapped to a particular queue during channel provisioning. Every time a new connection is added or deleted, the credit/bandwidth increment must be recomputed. Port queue thresholds are also introduced in addition to per-channel level thresholds:

Frames are dropped when either the channel threshold or the port queue threshold is exceeded. The credit/bandwidth increment on high-speed cards is important because it determines which queue will be serviced.

The formula to determine the credit for the connection is:

Credit/Bandwidth Increment = (Total CIR for connection type/Port speed) * Scaling Factor

where the Scaling Factor is 214 or 16384.

Figure 7-16 shows the egress traffic flow for the lower speed FRSM service modules.


Figure 7-16: FRSM Egress Flow


In summary, the traffic flow on FRSM cards is as follows.

Ingress Flow

The frame enters from the physical interface.

Step 1: Initial Processing

For the high-speed FRSM cards, the first 32 bytes are sent to the Ingress Service Engine (ISE) for processing. The frame header is read and the ISE first determines whether the frame is an LMI frame, an SVC frame, or neither type (a "data" frame).

Step 2: Policing

The dual leaky bucket algorithm is used to determine how frames are admitted to the network.

Step 3: Interworking

The necessary interworking functions as based on FRF.5 (Network Interworking) or FRF.8 (Service Interworking) are performed.

Step 4: IBS

This function is supported on a per-VC basis to favor connections that have been silent for a long time. For lower speed FRSM cards, this function is linked to policing. If the credit accumulated exceeds the IBS value, the frame is marked for IBS. On the high-speed FRSM cards, the ISE checks if a frame qualifies for IBS function. If the connection has been silent for more than the "QIR Timeout" amount of time, then an "IBS" number of bytes are transferred at a line rate with increased priority to transfer this data ahead of other connections. When "IBS" number of bytes are transmitted, the IR and priority of the connection are reset to their original values.

Step 5: Per-VC queuing

Traffic arriving at the network on a connection has its own dynamically assigned buffer at the entrance to the edge concentrator based on the amount of traffic and on the service-level agreement (SLA).

Step 6: Segmentation

The segmentation and reassembly engine (SAR) segments the frame into cells.

Egress Flow

The frame arrives from the cell bus and moves toward the physical interface.

Step 1: Initial Processing

The cell arrives from the cell bus and is delivered to the SAR Engine. The SAR uses the cell header to find the LCN/PTI.

If the cell is an OAM cell (PTI>=4), it is then sent to the OAM-receive queue, destined for the OAM module on the control processor.

If the cell is a management cell (reserved LCNs of 0-15), then the cell is sent to the management-receive queue, destined for the SCM module on the control processor.

If the cell is neither type (a "data" cell), then the cell is sent to the data-receive queue.

Step 2: Reassembly

The frame is reassembled from the cell.

Step 3: Queuing

While queuing the frame, if DE=1 and the queue depth of the logical port queue is > DE threshold, then the frame is discarded. At this point, FECN and BECN are updated for the outgoing frame by comparing the queue depth of the corresponding Ingress/Egress queue with the QECN threshold.

For the lower speed FRSM cards, there are two egress data queues: high and low priority. Traffic is queued up based on how the connection was configured. The high-priority queue is serviced N times for every one time that the low-priority queue is serviced.

For the high-speed FRSM cards:

ATM Service Module (AUSM/B)

For the AUSMT1/E1 cards the ingress/egress buffer size is 16Kcells.

Ingress Queuing

For each connection, a VC queue buffers the cells after they are policed and before they are sent to the cell bus. The purpose of the VC queue is to manage the traffic as it moves from the AUSM/B to the PXM 1 on the shelf. The VC queue has the additional function of shaping the ingress traffic on ABR channels.

The VC queue has several thresholds associated with it to mark and respond to congestion. The EFCI threshold defines the point where the MGX concentrator will tag incoming cells with the EFCI bit. The CLP high and low thresholds determine when CLP tagged cells (CLP=1) are discarded in the VC queue if CLP hysteresis is enabled for the connection (cnfchanq command). If frame-based traffic control is enabled, the EPD threshold determines when to start discarding an AAL5 frame. A connection can have only one method enabled; either CLP hysteresis or frame-based discard (EPD).

In summary, configurable VC queuing characteristics include the following:

Figure 7-17 shows the per-VC queuing on the AUSM/B cards.


Figure 7-17: Per-VC Queuing on AUSM/B Card


Egress Queuing

The egress port queues on the AUSM/B provide traffic management for multiple virtual circuits terminating on a single physical interface. A Qbin is a subqueue on an ATM port that buffers a specific type of traffic. For each port there is a CBR, VBR, ABR, and UBR Qbin.

Qbins are configured using the cnfportq command. Configurable parameters include the following:

Figure 7-18 shows the egress traffic flow for the lower speed AUSM/B service modules.


Figure 7-18: AUSM/B Egress Flow


Circuit Emulation Service Module (CESM)

Egress Queuing

On the CESM, data received over the network is buffered before transmitting online. Buffering takes care of cell delay variation (CDV) in the network. The minimum buffering (low threshold) is a function of CDV value specified for the channel.

The values given below are the maximum values of the buffers:

  For T1 UDT and E1 UDT: 16224 bytes
  For T1 SDT: 384 * N bytes
  For E1 SDT: 417 * N bytes
  For T3 UDT and E3 UDT: 16224 bytes
where N is the number of timeslots assigned in N x 64 connection.
N = 32 for UDT connections.

The buffer size specified for a channel sets the high-threshold value. The low-threshold value decides minimum delay experienced by data and the high-threshold value decides maximum delay experienced by data. If data is not received from the network for a long time, the egress buffer runs out of data and underflow is registered. When data reception resumes, the data is buffered until the low threshold amount of data is accumulated. During underflow, dummy data (0xff) is transmitted online and underflow inserted cell count is incremented.

If data builds up in the egress buffer and crosses the high-threshold mark, an overflow event is registered. Data produced to buffer until low mark is reached is discarded. The number of data bytes discarded during overflow is indicated by the overflow drop bytes counter.

Figure 7-19 shows the egress traffic flow for the lower speed CESM service modules.


Figure 7-19: CESM Egress Flow


Figure 7-20 shows the egress cell buffering on the CESM card.


Figure 7-20: CESM Egress Cell Buffer


Processor Switch Module (PXM 1)

The PXM 1 supports 256K of cell storage that is used by the QE ASICs for its queuing and buffering (128K of cell storage is allocated per direction).

In the switch fabric, there is buffering at three levels: VC queues, COS queues, and interface queues.

The VC queue parameters are currently defaulted as follows for all connections:

When a connection is provisioned, there are two parameters that are specified for handling CLP. They are the CLP hi and CLP lo thresholds. If the queue is full when the cell arrives, the cell is discarded. If the queue is filled above CLP hi, and the incoming cell has CLP=1, then the cell is discarded. If the queue is filled below CLP lo, then the cell is enqueued, regardless of its CLP setting. The area of the queue between CLP hi and CLP lo is called the "transition region." The transition region provides hysteresis for discarding incoming cells that have CLP=1. If the queue was filled above CLP hi but is now emptying such that it is in the transition region (but has not dropped below CLP lo), then incoming cells with CLP=1 are still discarded until the queue drops below the CLP lo threshold. Similarly, if the queue was filled below CLP lo but is now filling such that it is in the transition region (but has not filled above CLP hi), then all incoming cells are enqueued, regardless of their CLP setting.

The PXM 1 card can have up to four physical lines. The user can split the line resource into multiple partitions called broadband interfaces. The maximum number of interfaces on the PXM 1 card is 32. There is a 1:1 mapping of the broadband interface to the virtual interface on the QE. The QE implements virtual interface buffers and CoS buffers. A service group (virtual interface) is defined for each physical port on a card. A service group (VI) is also defined for each virtual trunk on the card. Multiple CoS buffers (Qbins), one for each of VBR-RT, VBR-NRT, CBR, ABR, and UBR are associated with each interface. Within each VI, there are 16 CoS queues. This configuration allows multiple service types to be configured across the same physical interface and allows high-priority traffic to bypass low-priority traffic, thus guaranteeing QoS. The VI and CoS queues can be programmed with the following parameters:


VI and COS Queues Architecture

From topology's point of view, there are three flows:

    1. SM1

    QE0

    SM2

    2. SM1

    QE1

    PXM 1 uplink

    3. PXM 1 uplink

    QE0

    SM1

All above connections topologies follow the same queuing flow on PXM 1. It is a two-stage process.

Stage 1: VI selection

Based on the minimum rate of each VI (there are 32 VIs on each QE; on QE0, each slot is mapped to a VI, and on PXM 1 uplink, each VI is mapped to a virtual interface—a logical partition of a physical link), QE selects one VI it needs to service to satisfy the rate requirement.

Stage 2: Qbin selection

Based on the Qbin MIN rate of each Qbin of the selected VI in stage 1, a Qbin is selected.

Once a Qbin is selected, the cell at the head of that Qbin queue is moved to the output queue for that physical link or slot to be transmitted.

Cells do not physically pass the VCQ. However, when a cell is being serviced, accounting is done for VCQ threshold function.

On the PXM 1, each QE is used for both directions (ingress and egress). Note that ingress and egress are defined from the perspective of QE on PXM 1 whereas on BXMs they are defined from the perspective of the backplane. With this definition, each switch path (except those terminating on PXM 1) has an ingress segment and an egress segment.

Separate queues can be used to support IP QoS.

IP QoS mechanisms use the three precedence bits in the type-of-service (ToS) field of the IP header to indicate IP precedence. Precedence values are used within the network to implement different service classes. There can be as many service classes as there are unique values of this three-bit field. Two of these values are reserved for traffic control, leaving six unique values for assignment to service classes.

Effective coupling of IP and ATM QoS is particularly challenging because of the differing paradigms (connectionless vs. connection-oriented). However, providing a seamless QoS capability between IP and ATM is essential when ATM is used as the backbone transport infrastructure for an IP VPN. This scenario allows QoS for intranet-based IP applications to take advantage of ATM QoS capabilities. MPLS is the key to this seamless integration.

In a VPN-aware network, the label header includes a CoS field with three bits to indicate a packet service class in a label-switched network. This value may be copied from the IP header when the label is applied, or it may be explicitly set by a precedence policy on the service provider edge router. As in an IP network, the CoS value is used to denote service class for each packet. When MPLS is implemented in an IP network, IP QoS capabilities are used the same way as in a traditional IP-routed network. In this case, however, service class is indicated by the CoS field in the label header instead of the IP header.

When the core of the service provider network uses ATM label switches, additional QoS capabilities are possible; they include:

Cisco edge concentrators such as the MGX 8250 provide IP service classes in addition to the standard ATM classes. These IP classes use a class-based queuing (CBQ) mechanism to implement separate queuing for IP flows while still utilizing the OptiClass buffer management feature to manage system buffers. This scenario allows the edge concentrator to provide ATM and Frame Relay services in parallel with IP while optimally allocating buffer space for all services.

Alternatively, MPLS allows a separate label VC to be used for each precedence value to a given destination. A percentage of link bandwidth can be allocated to each class of traffic using WFQ among classes to ensure that each class receives its allocated share of the link bandwidth. With the Cisco OptiClass buffer management feature, any unused bandwidth is automatically available to other classes. It is necessary to provision the link share appropriately to provide higher QoS to the higher classes. For example, if ten percent of the offered load on a link is expected to belong to a "premium" class, then allocating 15 percent of the link to the class with WFQ will ensure low-loss, low-delay service to that class.

Congestion Control Mechanisms

The AUSM/B modules perform ForeSight_ABR functions as the closed-loop end-to-end traffic management. These mechanisms allow maximizing the link utilization and avoiding the network congestion. The PXM1 supports EFCI tagging. Network uses the EFCI bit in the ATM cell header to indicate congestion. When congested, the concentrator sets an EFCI flag. The receiver must respond with "marked" RM cells and the sender will slow down upon receiving Congestion Indication (CI) in the Backward Resource Management cell (BRM).

The AUSM/B card conforms to ForeSight as a congestion-control mechanism. The MGX 8250 is capable of taking several actions based on the congestion status of the concentrator. The actions that the MGX 8250 can take are:

EFCI Bit

The different service modules on the MGX 8250 react to a set EFCI bit. Depending on the configuration, each service module can take different actions upon receiving a cell with the EFCI bit set.

The EFCI bit is used in the AUSM/B as mentioned follows:

Table 7-8 shows the mapping that can be configured on FRSM cards:


Table 7-8: FRSM Mapping Configurations

<FECN/EFCI>

Mapping between FECN and EFCI fields in the range 1-2.

1 = map EFCI, (this option valid only for service interworking)

2 = make EFCI 0

<DE to CLP>

DE to CLP mapping in the range 1 - 3.

1 = map DE to CLP,

2 = make CLP 0,

3 = make CLP 1.

<CLP to DE>

CLP to DE mapping in the range 1 - 4.

1 = map CLP to DE

2 = make DE 0,

3 = make DE 1,

4 = ignore CLP (this option valid only for network interworking.)

EPD/PPD Implementation

Two types of frame discard are supported for AAL5 traffic. The type of frame-discard mechanism is configurable per connection.

The QE uses an EPD feature as acceptance criteria for new AAL5 frames. This feature is also referred to as packet discard (PD) and frame-based traffic control (FBTC). Two EPD thresholds apply selective cell-discard principles to new frame acceptance criteria. EPD0 applies to all cells, while EPD1 applies only to cells with CLP=1. These are explained further as follows.

In addition to EPD, the QE implements a random early detection (RED) feature, in which full frames are randomly discarded with increasing probability as the CoS buffer's time-averaged queue length approaches its EPD threshold. It has been shown that RED improves the performance of TCP connections.

Early Packet Discard

EPD uses the EPD0 and EPD1 thresholds for the VCs and classes of service as the acceptance criteria for new AAL5 frames. The start-of-frame (SOF) cell is determined to be the next cell to arrive following an AAL5 end-of-frame (EOF) cell.

EPD attempts to discard entire frames. However, it is possible that a cell is discarded after one or more cells of the frame have been accepted. In this case, the remainder of the frame is discarded, except that the EOF is evaluated independently (to avoid corrupting the next new frame). This is referred to as tail packet discard. In this case, if the EOF is discarded at the end of a tail discard, the next frame is also discarded, to avoid sending a corrupted frame.

The QE allows packet-discard features to be enabled on a per-connection basis. To implement these features, the QE maintains a packet-discard state for each connection that has packet discard enabled. The purpose of maintaining the states is to differentiate between a full-packet discard and tail-packet (partial) discard. There are four packet discard states:

Transitions between the states occur only upon arrival of user data cells for the corresponding connection. When an EOF cell arrives, the state machine goes to the SOF state. If an SOF cell arrives, and its corresponding cell count exceeds its VC EPD threshold (or the CoS EPD threshold is exceeded), then the cell is discarded. Note that there are separate EPD0 and EPD1 thresholds for the CLP(0+1) and CLP(1) SOF cells. That is, if any SOF cell arrives, and the cell count exceeds the EPD0 threshold, the SOF (and the following frame) is discarded. However, if the SOF cell has CLP=1, and the cell count exceeds the EPD1 threshold (which is usually programmed lower than the EPD0 threshold), then the SOF cell is also discarded in this case.

The RPM (Route Processor Module) through the Port Adapter PA-A3 can perform EDP. The shaper will drop whole packets.