The PXM module performs shelf control and shared-memory switching functions. This chapter describes dialogs that show configuration information for:
Select the PXM card to display card configuration dialogs by doing one of the following:
The PXM Card Category menu contains the following dialogs:
![]() |
Note Some of these dialogs have sub-dialogs. |
Use the PXM Card Configuration dialog to view PXM card characteristics, hardware, firmware, and status information. The Card configuration dialog parameters are described in Table 9-1.

![]() |
Note This is not a configurable dialog. |
Use the PXM Features dialog to view PXM card features. (See Figure 9-2.)

The parameters are described in Table 9-2.
Parameter | Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
![]() |
Note This is not a configurable dialog. To modify these parameters, you must use the CLI. The commands related to this dialog are dspfeature and dspcd. |
The Shelf Configuration menu item provides several Shelf Configuration Dialogs.
![]() |
Note The Node dialog appears by default. |
Select one of the following dialogs from the Category pull-down menu in the config Shelf dialog:
These dialogs are described in the sections that follow.
Use the Node dialog to configure node properties. (See Figure 9-3.)

The Node dialog parameters are described in Table 9-3.
| Parameter | Description |
|---|---|
Node Name | Specifies the name of the node (and is unique among all the nodes in the network.) Whenever the name of the node is changed, AutoRoute has to propagate the information to the other nodes in the network. It also specifies the name of a PAR Feeder node.
|
Shelf Date | Sets the date for the shelf. The syntax is mm/dd/yyyy. |
Shelf Time | Sets the date for the shelf. The syntax is mm/dd/yyyy. |
Shelf Time Zone | Defines standard time for the shelf. Choose one from the popup menu:
To define a standard time not defined in here, use gmt and set the offset from the gmt in the Shelf Time Zone Offset parameter. |
Shelf Time Zone Offset (Hours) | Contains the offset from greenwich mean time in hours. If configuring for standard time in the Shelf Time Zone parameter, set this object to 0. If configuring for non standard times use this object as an offset from the GMT. |
Shelf Back Plane Type | Type of back plane, generally 336 Mbps. |
Shelf Back Plane SerialNo | Unique value for each shelf, entered in nvram by manufacturing. The serial number is on the non-volatile RAM on the backplane. |
Shelf Integrated Alarm | Status of the shelf's integrated alarm. Can be one of the following:
|
To modify an entry in the Node dialog:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information changed, re-select the Node dialog.
![]() |
Note Commands related to this dialog are cnfname, cnfdate, cnftime, cnftmzn, dspshelfalm. |
Use the Statistics Configuration dialog to view statistics information. (See Figure 9-4.)

The Statistics Configuration dialog parameters are described in Table 9-4.
Parameter | Description |
|
|
|
|
|
|
![]() |
Note This is not a configurable dialog. To modify these parameters, you must use the Command Line Interface (CLI). The command related to this dialog is dspstatparams. |
Use the Redundancy Info dialog to view and configure redundancy information. The Redundancy Info dialog parameters are described in Table 9-5.

To populate the Redundancy Info table with information, perform the following steps:

Table 9-6 describes the Create popup dialog parameters.
Parameter | Description |
|---|---|
|
|
|
|
|
|
Step 2 Enter the appropriate information.
Step 3 Click Apply.
To modify an entry in the Redundancy Info table:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the Redundancy Info dialog.
Use the APS-Redundancy Info dialog to view and configure APS-redundancy information. The parameters for this dialog are described in Table 9-7.
| Parameter | Description |
apsWorkingSlot | The chassis slot number of the working line. Slots 7 or 8 are permissible values. |
apsWorkingLine | The line number of the working line:
|
apsProtectionSlot | The chassis slot number of the protection line. Slots 7 or 8 are possible values. |
apsProtectionLine | The line number of the working line:
|
apsEnable | Enables or disables the APS feature on the working/protection line pairs. |
apsArchMode | Configures the APS architecture mode on the working/protection line pairs. |
apsActiveLine | Indicates which line is currently active on the trunk line. Possible values: 1 (apsWorkingLine) or 2 (apsProtectionLine). |
Use the LAN Interface Info dialog to view LAN interface information. (See Figure 9-8.)

The LAN Interface Info dialog parameters are described in Table 9-8.
| Parameter | Description |
|---|---|
InterfaceLn# | Interface line number. This number uniquely identifies the physical interface and service. |
InterfaceLn Type | Type of interface associated with the line. Can be one of the following:
|
InterfaceLn Ports | Number of physical ports for the line type. |
Interface ServiceType | Services available on this interface type. Can be one of the following:
|
Interface No. PVC | Maximum number of permanent virtual channels available per physical line. |
![]() |
Note The LAN Interface Info dialog is not a configurable dialog. |
Use the Serial Interface Info dialog to view and configure serial interface information. (See Figure 9-9.)

The Serial Interface Info dialog parameters are described in Table 9-9.
| Parameter | Description |
SerialPort# | Serial interface number. Port 1 is always defined as debug port. Port 2 on BSC can perform SLIP. |
SerialPort Type | Serial port type. Can be one of the following:
|
SerialPort Enable | Used to enable or disable the status of the serial port. |
SerialPort baudRate (bps) | Serial port Baud Rate. Choose one from the popup menu:
|
The only configurable parameters in this table are SerialPort Enable and SerialPort baud Rate. To modify these entries:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the Serial Interface Info dialog.
Use the Clock Source Info dialog to view clock source information. (See Figure 9-10.)

The Clock Source Info dialog parameters are described in Table 9-10
| Parameter | Description |
|---|---|
Current Clock | Clock source currently selected for PXM card. Can be one of the following:
If the Current Clock is primary, the Primary Clock Source further describes the clock source. If the PXM Current Clock is secondary, the PXM Secondary Clock Source further describes the clock source. |
pxmPreviousClock | Clock source previously selected for PXM card. Can be one of the following:
|
Primary Clock Source | Primary Clock source for the PXM card. Can be one of the following:
|
Primary Inband Clock Source | Primary Inband clock source. If the Primary Clock Source is the same as the Primary SM Clock or the Secondary SM Clock Source, this entry indicates the Inband Line number. |
Primary SM Clock Source Slot | Primary service module Slot Number. |
Secondary Clock Source | Secondary clock source. For Primary Inband Clock Source and Secondary Inband Clock Source, this parameter describes the line number that the clock is derived from. For Primary SM Clock Source Slot and Secondary SM Clock Source Slot, this parameter describes the SM slot number. Can be one of the following:
|
Secondary Inband Clock Source | Secondary Inband clock source. |
Secondary SM Clock Source Slot | Secondary SM clock source slot. |
External Clock Present | Indicates whether or not an external clock is present. Can be clkNotPresent or clkPresent. |
External Clock Source Impedence | Impedance on the external clock input for the card. Can be one of the following:
|
External Clock Connector Type | Type of connector available for connecting the external clock source to the PXM-LM. |
![]() |
Note This is not a configurable dialog. To modify clock source information parameters, you must use the CLI. |
Use the Front Card Info dialog to view and configure front card information. (See Figure 9-11.)

The Front Card Info table parameters are described in Table 9-11.
| Parameter | Description | ||
|---|---|---|---|
Shelf Number | Shelf number. | ||
Slot Number | Slot number. The MGX 8250 can have a maximum of 32 slots in one shelf. | ||
Function Module State | State of the front card. Can be one of the following:
| ||
Function Module Type | Front card type in a particular shelf-slot. | ||
Set to HoldInReset? | HoldInReset holds the card in a particular shelf-shot in reset. doNotHold only resets the card in the specified slot. |
To modify an entry in the Front Card Info table:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the Front Card Info dialog.
The command related to this dialog is dspcds.
Use the CellBusRates Parameter dialog to view and configure cell bus information. (See Figure 9-12.)

The CellBus RatesParameter is described in Table 9-12.
Parameter | Description |
|
|
|
|
Select one of the following dialogs from the Category pull-down menu in the config PAR dialog:
These dialogs are described in the sections that follow.
Use the PAR Self Node dialog to view and configure PAR self node on a PXM card. (See Figure 9-13.)

The PAR Self Node dialog parameters are described in Table 9-13.
Parameter | Description |
|
|
|
|
|
|
|
|
|
|
To modify an entry in the PAR Self Node table:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has been changed, re-select the PAR Self Node table.
Use the PAR Interface dialog to view and configure PAR Interface information. The PAR Interface dialog parameters are described in Table 9-14.

| Parameter | Description |
|---|---|
parIfLogicalInterface | Specifies the logical interface number assigned by Platform Software. |
parIfType | Specifies the type of interface. Choose one from the popup menu:
|
parIfOperStatus | Specifies the operation status of the interface. Can be one of the following:
For interfaces of type UNI, the status is either up or down as reported by platform. For interfaces of type NNI, the status is up, added, down, or added-failed. |
parIfTxBw | Specifies the transmit bandwidth for the interface in units of cells per second. |
parIfRxBw | Specifies the receive bandwidth for the interface in units of cells per second. |
parIfMaxConn | Specifies the maximum number of connections that can be configured over the interface. |
parIfHiAddrMin | Specifies the minimum VPI that PAR can use for configuring connection in the interface. |
parIfHiAddrMax | Specifies the maximum VPI that PAR can use for configuring connection in the interface. |
parIfLoAddrMin | Specifies the minimum VCI that PAR can use for configuring connection in the interface. |
parIfLoAddrMax | Specifies the maximum VCI that PAR can use for configuring connection in the interface. |
The only configurable parameter in this table is parIfType. To modify this entry:
Step 5 Click in the parIfType entry to display possible values.
Step 6 Select the appropriate value.
Step 7 Click Modify.
To make sure the information has changed, re-select the PAR Interface table.
Use the PAR Trunk Interface dialog to view and configure PAR Trunk Interface information. (See Figure 9-15.)

The PAR Trunk Interface dialog parameters are described in Table 9-15.
| Parameter | Description | ||
|---|---|---|---|
parIfLogicalInterface | Specifies the logical interface number assigned by Platform Software. | ||
parTrkId | Specifies the logical trunk number associated with the trunk at the local node. | ||
parTrkStatReserve | Specifies the bandwidth reserved as Statistical Reserve on the trunk in units of cells per second. This object cannot take a value beyond the bandwidth capacity of the trunk. | ||
parTrkCnfgPassSync | Specifies whether the trunk can be used to pass clock sync. Choose one from the popup menu:
| ||
parTrkCnfgAdminStatus | Used to add or delete the trunk. The default setting for this object is 0. Choose one from the popup menu:
| ||
parTrkCnfgVpcConids | Specifies the maximum number of routing resource available on the trunk for VPC connections. The default is 0. Choose add or delete from the popup menu. | ||
parTrkCnfgVccConids | Specifies the maximum number of routing resource available on the trunk for VCC connections. The default is 0. Choose add or delete from the popup menu. | ||
parTrkLocalSlotNumber | Specifies the slot number of the interface card associated with the trunk at the local node. | ||
parTrkLocalPortNumber | Specifies the port number of the interface card associated with the trunk at the local node. | ||
parTrkLocalVTrunkId | Specifies the virtual trunk of the interface card associated with the trunk at the local node. The value of this object is between | ||
parTrkRemoteTrunkId | Specifies the logical trunk number at the node on the remote end of the trunk. | ||
parTrkRemoteSlotNumber | Specifies the logical trunk number at the node on the remote end of the trunk. | ||
parTrkRemotePortNumber | Specifies the port number of the interface card to which the trunk is attached on the remote node. | ||
ParTrkRemoteVTrunkId | Specifies the virtual trunk of the interface card associated with the trunk at the remote node. The value of this object is between 1 and 254, inclusive for a virtual trunk and 255 for a physical trunk. | ||
ParTrkRemoteNodeIP | Specifies the IP address for the remote node, used for communication with NMS. | ||
ParTrkRemoteNodeType | Specifies the type of the node. Can be one of the following:
| ||
ParTrkRemoteNodeName | Specifies the name of the remote node and is unique among all the nodes in the network. | ||
ParTrkAlarmStatus | Specifies the severity of the alarm on the trunk. Can be one of the following:
| ||
ParTrkAlarm type | Specifies the type of alarm on the trunk. The value of this object has no significance if parTrkAlarmStatus indicates no alarm. Can be one of the following:
| ||
ParTrkLineLoad | Specifies the amount of bandwidth used to provide connections routed over the trunk. | ||
ParTrkBwCapacity | Specifies trunk bandwidth capacity. |
To modify an entry in the PAR Trunk Interface table:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the PAR Self Node table.
Use the PAR Connection Management dialog to view and configure PAR Connection Management information. (See Figure 9-16.)

The PAR Interface dialog parameters are described in Table 9-16.
Parameter | Description |
|
|
|
|
To modify a parameter in the PAR Connection Management dialog:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the PAR Connection Management dialog.
Use the PAR SW Function dialog to view and configure PAR SW Function information. (See Figure 9-17.)

The PAR SW Function dialog parameters are described in Table 9-17.
Parameter | Description |
|
|
|
|
To modify a parameter in the PAR SW Function dialog:
Step 2 Click Modify.
To make sure the information has changed, re-select the PAR SW Function dialog.
Use the PAR Systems Parameters dialog to view and configure PAR System information. (See Figure 9-18.)

The PAR System Parameters are described in Table 9-18.
Parameter | Description |
|
|
|
|
|
|
To modify the parSysParmsTSPacketAge parameter in the PAR System Parameters dialog:
Step 2 Click Modify.
To make sure the information has changed, re-select the PAR System Parameters dialog.
Use the PAR Network Parameter dialog to view and configure PAR Network information. (See Figure 9-19.)

The PAR Network Parameter is described in Table 9-19.
Parameter | Description |
|
|
To modify the parNetParmNetwLetWait parameter:
Step 2 Click Modify.
To make sure the information has changed, re-select the PAR Network Parameter dialog.
Use the PAR Clock Parameters dialog to view and configure PAR Clock Parameters. (Figure 9-20.)

The PAR Clock Parameters are described in Table 9-20.
Parameter | Description |
|
|
|
|
|
|
|
|
To modify an entry in the PAR Clock Parameters table:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the PAR Clock Parameters table.
The Broadband Interfaces menu item provides several Broadband Interfaces dialogs.
![]() |
Note The Broadband Interface table appears by default. |
Select one of the following dialogs from the Category pull-down menu in the config Shelf dialog:
These dialogs are described in the subsections that follow.
Use the Broadband Interface dialog to configure an interface on a PXM card. (See Figure 9-21.)

The Broadband Interface table parameters are described in Table 9-21.
Parameter | Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To populate the Broadband Interface table with Information:
The following popup dialog appears:

Table 9-22 describes the parameters in the Create popup dialog parameters.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
Step 2 Enter the appropriate information.
Step 3 Click Apply.
To modify an entry in the Broadband Interface table:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the Broadband Interface table.
Use the Resource Partition dialog to view and configure resource partition information. (See Figure 9-23.)

The Resource Partition table parameters are described in Table 9-23.
Parameter | Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To populate the Resource Partition dialog with information:
![]() |
Note The parameters in this dialog correspond to those in the Resource Partition table. |
Step 2 Enter the appropriate information.
Step 3 Click Apply.
To modify an entry in the Resource Partition table:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the Resource Partition table.
Use the State dialog to view broadband interface state information. (See Figure 9-24.)

The State table parameters are described in Table 9-24.
Parameter | Description |
|
|
|
|
|
|
|
|
|
|
![]() |
Note This is not a configurable table. To configure these parameters, use the CLI. |
Use the PXM Interface Counters Dialog to view PXM interface counters information. (See Figure 9-25.)

The PXM Interface Counters table parameters are described in Table 9-25.
Parameter | Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To modify an entry in the PXM Interface Counters dialog:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the PXM Interface Counters table.
Use the ILMI dialog to view ILMI parameters. The ILMI table parameters are described in Table 9-26.

| Parameter | Description | ||
|---|---|---|---|
bbIfSigPortNum | Refers to the logical interface index on the PXM card. | ||
bbIfILMIenable | Used to enable/disable ILMI. Logical interface is a generic entity, it can be used as either a virtual trunk, or user port with UNI support.
| ||
bbIfSignallingProtocolType | Sets the signalling protocol. Choose one from the popup dialog:
| ||
bbIfSignallingVpi | Indicates the VPI on which signalling cells arrive. The range is from 0..4095. | ||
bbIfSignallingVci | Indicates the VCI on which signalling cells arrive. | ||
bbIfAddrPrefix | Network Prefix for the ATM address. | ||
bbIfCustomerId | For the INS as a read/write variable. | ||
bbIfProtocolRevNum | For the INS as a read/write variable. | ||
bbIfIlmiTrapEnable | Used to enable/disable ILMI Trap sending. | ||
bIfMinTrapInterval | Number of seconds between traps. | ||
bbIfKeepAlivePollingEnable | Used to enable/disable Keep Alive Polling. | ||
bbIfErrorThresholdN491 | Error Threshold (N491) value. The range is 1..10. | ||
bbIfErrorThresholdN492 | Error Threshold (N492) value. The range is 1..10. | ||
bbIfPollingIntervalT491 | Polling Interval (T491) value. The range is v1..v12. | ||
bbIfMinEnquiryIntervalT493 | Minimum Enquiry Interval. The range is 1..20. | ||
bbIfAddreRegEnable | Used to enable/disable ILMI Address Registration. |
To modify an entry in the ILMI table:
Step 2 Click in the entry to display possible values.
Step 3 Select the appropriate value.
Step 4 Click Modify.
To make sure the information has changed, re-select the ILMI table.
Use the LCN Partition Type dialog to configure the LCN partition type on a PXM card. (See Figure 9-27.)
Choose one from the pulldown menu under cardLcnPartitionType:
|
|
|
|
|
|
![]() |
Note This dialog must be configured before adding any connections. Once a connection is added, this dialog cannot be changed until all of the connections are deleted. |
To modify LCN partition type, make the changes you want and click Modify.
There are four ways to select the line (using either a front or rear view of the card) to display the appropriate line configuration dialog:
To display the configuration parameters for a particular line/port, select the name of the category from the Category popup menu at the top of the dialog. The categories of line configuration available are:
Use these dialogs to view and configure dsx3 line information. (If you reached any of these dialogs by device selection, the total number of rows read is displayed at the bottom of the dialog.) To select another line for viewing, enter a line number in the LINE field at the top of the dialog. The dialog is refreshed and displays the new information.
The categories of line configuration for dsx3 lines are:
These dialogs are described in the sections that follow.
Use the Physical Line Configuration dialog to view and configure dsx3 physical line configuration information. (See Figure 9-28.)

The Physical Line Configuration (dsx3) dialog parameters are described in Table 9-27.
| Parameter | Description |
|---|---|
Line Number | Line number. |
Line Enable | Choose enable or disable. |
Line Type | Line type Choose one from the popup menu:
|
Line Coding | Line coding. Can be dsx3B3ZS or e3HDB3. |
Line Length (Feet) | Line length. Choose lessThan225 or moreThan225 from the popup menu. |
Line OOF Criteria | Line OOF decision criteria. Can be fBits30f8 or fBits3Of16. |
Line check AIS Bits? | Choose checkCbits or ignorebits from the popup menu. If checkCbits, AIS is declared when 1010 pattern is found and C-Bits are all zero. If ignorebits, an AIS condition is declared when the AIS pattern 1010 is detected, regardless of the state of the C-Bits. |
Line Loopback Command | Loopback configuration of the DS3/E3 interface. Choose one from the popup menu:
|
Line Receive FEAC Validation | Far-end alarm and control (FEAC) code validation criteria. Choose fFEACCodes4Of5 or fFEACCodes8Of10 from the popup menu. If FEACCodes4Of5 is specified, a valid FEAC codes is declared if four of five codes match. If fFEACCodes8Of10 is specified, a valid FEAC code is declared when eight of ten codes match. |
Line Transmit FEAC Code | Indicates the bit-oriented code to transmit over the far-end alarm and control (FEAC) channel. Choose one from the popup menu:
|
Line XMT Clock Src | Line transmit clock source. Choose one from the popup menu:
|
Far End Loopback Status | Bitmap of the dsx3 FarEnd line loopback status bits. |
Line Equalizer | Determines type of line equalizer. Choose one from the popup menu:
|
To modify the parameters, make the changes you want and click Modify.
Use the dsx3 Physical Line Alarm Configuration dialog to view and configure dsx3 physical line alarm information. (See Figure 9-29.)

The dsx3 Physical Line Alarm Configuration dialog parameters are described in Table 9-28.
| Parameter | Description |
|---|---|
Line Alarm State | Status of the line alarm. A value of zero indicates no alarms. |
Line Statistical Alarm State | Status of the line statistical alarms. A value of zero indicates no alarms. |
Red Severity | Used to set up the severity of RED alarm. When an LOS/LOF alarm is detected, the BNM sends the alarm with the appropriate alarm status. Can be minor or major. |
RAI Severity | Used to set up the severity of RAI alarm. When RAI alarm is detected, the BNM sends the alarm with the appropriate alarm status. Can be minor or major. |
Near End Alarm Up Count | Specifies the increment to the near-end alarm integration counters. The local alarms are LOS and LOF. The default is 6, and the integration counter is incremented by this value every 10 milliseconds when the alarm persists. The counter is decremented by the value of Near End Alarm Down Count while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds dsx3NEAlarmThreshold, an alarm of the severity specified for the particular NE alarm is declared. |
Near End Alarm Down Count | Specifies the decrement to the near-end alarm integration counters. The local alarms are LOS and LOF. The default is 1, and the integration counter is decremented by this value every 10 milliseconds while no alarm persists. The counter is incremented by the value of Near End Alarm Up Count while there is no alarm (the counter does not decrement below zero). When the integration counter reaches zero, any alarm previously declared is removed. |
Near End Alarm Threshold | Determines the value that the alarm integration counter must reach for a near-end alarm to be declared. If the up count is 6, the down count is 1, and the threshold is 1500, an alarm is integrated in 2.5 seconds and removed in 15 seconds. |
Far End Alarm Up Count | Determines the value that the alarm integration counter must reach for a near-end alarm to be declared. If the up count is 6, the down count is 1, and the threshold is 1500, an alarm is integrated in 2.5 seconds and removed in 15 seconds. |
Far End Alarm Down Count | Specifies the decrement to the far-end alarm integration counters. The local alarms are RAI and AIS. The default is 1, and the integration counter is decremented by this value every 10 milliseconds while no alarm persists. The counter is incremented by the value of Far End Alarm Up Count while there is no alarm (the counter does not decrement below zero). When the integration counter decrements to zero, any previously declared alarm is removed. |
Far End Alarm Threshold | Determines the value that the alarm integration counter must reach for a far-end alarm to be declared. If the up count is 6, the down count is 1, and the threshold is 1500, an alarm is integrated in 2.5 seconds and removed in 15 seconds. |
Statistical Alarm Severity | Used to set up the severity of any of the statistical alarms. When a statistical counter exceeds it specified threshold, the AUM sends the alarm with the appropriate severity. Can be minor or major. |
To modify the parameters, make the changes you want and click Modify.
There are two dialogs for dsx3 counter configuration. Use the dsx3 Counters dialogs to view and configure dsx3 Counters. (See Figure 9-30 and Figure 9-31.)

The dsx3 Counters (1 of 2) dialog parameters are described in Table 9-29.
| Parameter | Description |
|---|---|
dsx3CounterClrButton | Choose noAction or clear. |
Rcv LOS Count | Number of times the Loss of Signal is detected with or without integrating to LOS alarm. |
Rcv OOF Count | Number of times the Out Of Frame is detected with or without integrating to OOF alarm. |
RAI Count | Number of times yellow alarms is detected with or without integrating to RAI alarm. |
CCV Count | Number of C Bit Coding Violations encountered by a DS3/E3 interface. |
FE Count | Number of Framing Pattern Errors encountered by a DS3/E3 interface. |
LCV Current | Number of Line Code Violations encountered by the interface. |
LCV 15 Min Bucket | Number of Line Code Violations in the last 15-minute period encountered by the interface. |
LCV 24 Hr Bucket | Number of Line Code Violations in the last 24-hour period encountered by the interface. |
LES Current | Number of Line Code Violations Errored Seconds encountered by the interface. |
LES 15 Min Bucket | Number of Line Code Violations Errored Seconds in the last 15-minute period encountered by the interface. |
LES 24 Hr Bucket | Number of Line Code Violations Errored Seconds in the last 24-hour period encountered by the interface. |
LSES Current | Number of Line Code Violations Severely Errored Seconds encountered by the interface. |
LSES 15 Min Bucket | Number of Line Code Violations Severely Errored Seconds in the last 15-minute period encountered by the interface. |
LSES 24 Hr Bucket | Number of Line Code Violations Severely Errored Seconds in the last 24-hour period encountered by the interface. |
PCV Current | Number of P-Bit Code Violations encountered by the interface. |
PCV 15 Min Bucket | Number of P-Bit Code Violations in the last 15-minute period encountered by the interface. |
PCV 24 Hr Bucket | Number of P-Bit Code Violations in the last 24-hour period encountered by the interface. |

The dsx3 Counters (2 of 2) dialog parameters are described in Table 9-30.
| Parameter | Description |
|---|---|
dsx3CounterClrButton | Clears all dsx3 counters. Choose noAction or clear. |
dsx3LineAlarmClrButton | Clears all dsx3 line alarms. Choose noAction or clear. |
PES Current | Number of P-Bit Code Violations Severely Errored Seconds encountered by the interface. |
PES 15 Min Bucket | Number of PCV Severely Errored Seconds in the last 15-minute period encountered by the interface. |
PES 24 Hr Bucket | Number of PCV Severely Errored Seconds in the last 24-hour period encountered by the interface. |
PSES Current | Number of Severely Errored Framing Seconds encountered by the interface. |
PSES 15 Min Bucket | Number of PCV Severely Errored Seconds in the last 15-minute period encountered by the interface. |
PSES 24 Hr Bucket | Number of PCV Severely Errored Seconds in the last 24-hour period encountered by the interface. |
SEFS Current | Number of Severely Errored Framing Seconds encountered by the interface. |
SEFS 15 Min Bucket | Number of Severely Errored Framing Seconds in the last 15-minute period encountered by the interface. |
SEFS 24 Hr Bucket | Number of Severely Errored Framing Seconds in the last 24-hour period encountered by the interface. |
AISS Current | Number of AIS Severely Errored Seconds encountered by the interface. |
AISS 15 Min Bucket | Number of AIS Severely Errored Seconds in the last 15-minute period encountered by the interface. |
AISS 24 Hr Bucket | Number of AIS Severely Errored Seconds in the last 24-hour period encountered by the interface. |
UAS Current | Number of Unavailable Seconds encountered by the interface. |
UAS 15 Min Bucket | Number of Unavailable Seconds in the last 15-minute period encountered by the interface. |
UAS 24 Hr Bucket | Number of Unavailable Seconds in the last 24-hour period encountered by the interface. |
Percent LCV EFS | Percentage of seconds without any LCV Errors in the total elapsed seconds. |
To modify the parameters, make the changes you want and click Modify.
These dialogs show sonet line configuration information. (If you reached any of these dialogs by device selection, the total number of rows read is displayed at the bottom of the dialog.) To select another line for viewing, enter a line number in the LINE field at the top of the dialog. The dialog is refreshed and displays the new information.
There are four dialogs for configuring SONET lines:
These dialogs are described in the sections that follow.
Use the Physical Line Config (SONET) dialog to view and configure SONET physical line information. (See Figure 9-32.)

The Physical Line Config (SONET) dialog parameters are described in Table 9-31.
| Parameter | Description |
|---|---|
Sonet Line Number | Line number. |
AXISSonetLineEnable | Cell framing. The default is STM-1. |
Sonet Line Type | Cell Framing. The default is STM-1. |
Line Loopback Command | Loopback Configuration of the SONET Interface. Can be one of the following:
|
Line HCS Masking | HCS masking. Can be disable or enable. The default is enable. |
Line Payload Scrambling | STS3c or STM-1 payload scrambling. Can be disable or enable. The default is enable. |
Line Frame Scrambling | STS3c or STM-1 frame scrambling. Can be disable or enable. The default is enable |
Sonet Medium Type | Identifies whether or not a SONET or an SDH signal is used across this interface. Can be SONET or sdh. |
Sonet Medium Time Elapsed (Secs) | Number of seconds, including partial seconds, that have elapsed since the beginning of the mandatory error-measurement period. |
Sonet Medium Valid Intervals | Number of previous intervals for which valid data has been stored. A SONET device must support at least n intervals, where n: 4 = minimum value 32 = default value 96 = maximum value The value of this object is n unless the device was brought on-line within the last nx15 minutes, in which case the value is the number of complete 15-minute intervals the device has been on-line. |
Sonet Line Coding | Line Coding for the SONET interface. Can be one of the following:
|
Sonet Line Type | Line type for the SONET interface. The line types are Short and Long Range Single Mode fiber or Multi-Mode fiber interfaces, and coax and UTP for electrical interfaces. Can be one of the following:
|
Sonet Circuit Identifier | Transmission vendor's circuit identifier for facilitating troubleshooting. |
Use the Physical Line Alarm Config (SONET) dialog to view and configure SONET physical line alarm information. (See Figure 9-33.)

The Physical Line Alarm Config (SONET) dialog parameters are described in Table 9-32.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Use the SONET Counters dialog to view and configure SONET counters. (See Figure 9-34.)

The SONET Counters dialog parameters are described in Table 9-33.
| Parameter | Description |
|---|---|
AXISsonetSectionCurrentClrButton | Clears all the section's current 15 minute counters. Choose noAction or clear. |
AXISsonetSectionCurrentDayClrButton | Clears all the section's current Day counters. Choose noAction or clear. |
AXISsonetSectionCounterClrButton | Clears all the section's counters. Choose noAction or clear. |
AXISsonetLineCurrentClrButton | Clears all the SONET line's current 15 minute counters. Choose noAction or clear. |
AXISsonetLineCurrentDayClrButton | Clears all the SONET line's current Day counters. Choose noAction or clear. |
AXISsonetFarEndLineCurrentClrButton | Clears all the SONET Far End Line's current 15 minute counters. Choose noAction or clear. |
AXISsonetFarEndLineCurrentDayClrButton | Clears all the SONET Far End Line's current Day counters. Choose noAction or clear. |
AXISsonetLineCounterClrButton | Clears all the SONET line's counters. Choose noAction or clear. |
AXISsonetPathCurrentClrButton | Clears all the SONET path's current counters. Choose noAction or clear. |
AXISsonetPathCurrentDayClrButton | Clears all the SONET path's current Day counters. Choose noAction or clear. |
AXISsonetFarEndPathCurrentClrButton | Clears all the SONET Far End path's current 15 minute counters.Choose noAction or clear. |
AXISsonetFarEndPathCurrentDayClrButton | Clears all the SONET Far End path's current Day counters. Choose noAction or clear. |
AXISsonetPathCounterClrButton | Clears all the SONET path's counters. Choose noAction or clear. |
Use the ATM Lines dialog to view and configure ATM line information. (See Figure 9-35.)

The ATM Lines dialog parameters are described in Table 9-34.
Parameter | Description |
|---|---|
|
|
|
|
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Oct 2 21:13:03 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.