There are four ways to select the line (from either the front or rear view of the card) to display the appropriate Line Monitor dialog:
To view the parameters in line graph format, use the HP OpenView Grapher application. Select the parameters by clicking once, then click the Grapher button. The Monitor dialog remains open.
There are two dialogs for monitoring dsx1 counters:
Use the dsx1 Counters dialogs to view dsx1 Counters. (See Figure 13-1 and Figure 13-2.)

The dsx1 Counter (1 of 2) dialog parameters are described in Table 13-1.

The dsx1 Counter (2 of 2) dialog parameters are described in Table 13-2.
| Parameter | Description |
|---|---|
CRCES Current | Number of CRC Errored Seconds encountered by the interface. |
CRCES 15 Min Bucket | Number of CRC Errored Seconds in the last 15-minute period encountered by the interface. |
CRCES 24 Hr Bucket | Number of CRC Errored Seconds in the last 24-hour period encountered by the interface. |
CRCSES Current | Number of PCV Errored Seconds encountered by the interface. |
CRCSES 15 Min Bucket | Number of PCV Errored Seconds in the last 15-minute period encountered by the interface. |
CRCSES 24 Hr Bucket | Number of PCV Errored Seconds in the last 15-minute period encountered by the interface. |
SEFS Current | Number of Severely Errored Framing Seconds encountered by the interface. |
SEFS 15 Min Bucket | Number of Severely Errored Framing Seconds in the last 15-minute period encountered by the interface. |
SEFS 24 Hr Bucket | Number of Severely Errored Framing Seconds in the last 24-hour period encountered by the interface. |
AISS Current | Counts the number of AIS Severely Errored Seconds encountered by the interface. |
AISS 15 Min Bucket | Number of AIS Severely Errored Seconds in the last 15-minute period encountered by the interface. |
AISS 24 Hr Bucket | Number of AIS Severely Errored Seconds in the last 24-hour period encountered by the interface. |
UAS Current | Number of Unavailable Seconds encountered by the interface. |
UAS 15 Min Bucket | Number of Unavailable Seconds in the last 15-minute period encountered by the interface. |
UAS 24 Hr Bucket | Number of Unavailable Seconds in the last 24-hour period encountered by the interface. |
Percent EFS | Percentage of seconds without any LCV Errors in the total elapsed seconds. |
There are two dialogs for monitoring dsx3 counters. Use the dsx3 Counters dialogs to view dsx3 Counters. (See Figure 13-3 and Figure 13-4.)

The dsx3 Counters dialog parameters are described in Table 13-3.
| Parameter | Description |
|---|---|
Rx LOS Count | Number of times the Loss of Signal is detected with or without integrating to LOS alarm. |
Rx OOF Count | Number of times the Out Of Frame is detected with or without integrating to OOF alarm. |
RAI Count | Number of times yellow alarms is detected with or without integrating to RAI alarm. |
CCV Count | Counter associated with the number of C Bit Coding Violations encountered by a DS3/E3 interface. |
FE Count | Number of Framing Pattern Errors encountered by a DS3/E3 interface. |
LCV Current | Number of Line Code Violations encountered by the interface. |
LCV 15 Min Bucket | Number of Line Code Violations in the last 15-minute period encountered by the interface. |
LCV 24 Hr Bucket | Number of Line Code Violations in the last 24-hour period encountered by the interface. |
LES Current | Number of Line Code Violations Errored Seconds encountered by the interface. |
LES 15 Min Bucket | Number of Line Code Violations Errored Seconds in the last 15-minute period encountered by the interface. |
LES 24 Hr Bucket | Number of Line Code Violations Errored Seconds in the last 24-hour period encountered by the interface. |
LSES Current | Number of Line Code Violations Severely Errored Seconds encountered by the interface. |
LSES 15 Min Bucket | Number of Line Code Violations Severely Errored Seconds in the last 15-minute period encountered by the interface. |
LSES 24 Hr Bucket | Number of Line Code Violations Severely Errored Seconds in the last 24-hour period encountered by the interface. |
PCV Current | Number of P-Bit Code Violations encountered by the interface. |
PCV 15 Min Bucket | Number of P-Bit Code Violations in the last 15-minute period encountered by the interface. |
PCV 24 Hr Bucket | Number of P-Bit Code Violations in the last 24-hour period encountered by the interface. |
PES Current | Number of PCV Errored Seconds encountered by the interface. |
PES 15 Min Bucket | Number of PCV Errored Seconds in the last 15-minute period encountered by the interface. |
PES 24 Hr Bucket | Number of PCV Errored Seconds in the last 24-hour period encountered by the interface. |

The dsx3 Counters dialog parameters are described in Table 13-4.
| Parameter | Description |
|---|---|
PSES Current | Number of P-Bit Code Violations Severely Errored Seconds encountered by the interface. |
PSES 15 Min Bucket | Number of PCV Severely Errored Seconds in the last 15-minute period encountered by the interface. |
PSES 24 Hr Bucket | Number of PCV Severely Errored Seconds in the last 24-hour period encountered by the interface. |
SEFS Current | Number of Severely Errored Framing Seconds encountered by the interface. |
SEFS 15 Min Bucket | Number of Severely Errored Framing Seconds in the last 15-minute period encountered by the interface. |
SEFS 24 Hr Bucket | Number of Severely Errored Framing Seconds in the last 24-hour period encountered by the interface. |
AISS Current | Counter counts the number of AIS Severely Errored Seconds encountered by the interface. |
AISS 15 Min Bucket | Number of AIS Severely Errored Seconds in the last 15-minute period encountered by the interface. |
AISS 24 Hr Bucket | Number of AIS Severely Errored Seconds in the last 24-hour period encountered by the interface. |
UAS Current | Number of Unavailable Seconds encountered by the interface. |
UAS 15 Min Bucket | Number of Unavailable Seconds in the last 15-minute period encountered by the interface. |
UAS 24 Hr Bucket | Number of Unavailable Seconds in the last 24-hour period encountered by the interface. |
CCV Current | Number of C-Bit parity Code Violations encountered by the interface. |
CCV 15 Min Bucket | Number of C-Bit parity Code Violations in the last 15-minute period encountered by the interface. |
CCV 24 Hr Bucket | Number of C-Bit parity Code Violations in the last 24-hour period encountered by the interface. |
CES Current | Number of C-Bit parity Errored Seconds encountered by the interface. |
CES 15 Min Bucket | Number of C-Bit parity Errored Seconds in the last 15-minute period encountered by the interface. |
CES 24 Hr Bucket | Number of C-Bit parity Errored Seconds in the last 24-hour period encountered by the interface. |
CSES Current | Number of C-Bit parity Severely Errored Seconds encountered by the interface. |
CSES 15 Min Bucket | Number of C-Bit parity Severely Errored Seconds in the last 15-minute period encountered by the interface. |
CSES 24 Hr Bucket | Number of C-Bit parity Severely Errored Seconds in the last 24-hour period encountered by the interface. |
Percent LCV EFS | Percentage of seconds without any LCV Errors in the total elapsed seconds. |
There are two dialogs for monitoring dsx3 PLCP counters:
Use the Dsx3 Counters dialogs to view Dsx3 Counters. The dsx3 PLCP Counters (1 of 2) dialog parameters are described in Table 13-5.
| Parameter | Description |
|---|---|
Rcv Bip-8 Cnt | Number of BIP-8 errors. |
Rcv OOF Cnt | Number of times the Out Of Frame is detected with or without integrating to OOF alarm. |
Rcv RAI Cnt | The number of times yellow alarms is detected with or without integrating to RAI alarm. |
FE Cnt | Number of framing errors detected. |
FE Sec Cnt | Number of framing error errored seconds. |
SEFE Sec Cnt | Number of severely errored framing error seconds. |
FEBE Cnt | Number of FEBE errors. |
FEBE Sec Cnt | Number of errored FEBE seconds. |
SEFBE Sec Cnt | Number of severely errored FEBE seconds. |
Hec Cnt | Number of HEC errors. |
Hec Sec Cnt | Number of errored HEC seconds. |
SEHEC Sec Cnt | Number of severely errored HEC seconds. |
The dsx3 PLCP Counters (2 of 2) dialog parameters are described in Table 13-6.
| Parameter | Description |
|---|---|
PSES Current | Number of P-Bit Code Violations Severely Errored Seconds encountered by the interface. |
PSES 15 Min Bucket | Number of PCV Severely Errored Seconds in the last 15-minute period encountered by the interface. |
PSES 24 Hr Bucket | Number of PCV Severely Errored Seconds in the last 24-hour period encountered by the interface. |
SEFS Current | Number of Severely Errored Framing Seconds encountered by the interface. |
SEFS 15 Min Bucket | Number of Severely Errored Framing Seconds in the last 15-minute period encountered by the interface. |
SEFS 24 Hr Bucket | Number of Severely Errored Framing Seconds in the last 24-hour period encountered by the interface. |
AISS Current | Number counts the number of AIS Severely Errored Seconds encountered by the interface. |
AISS 15 Min Bucket | Number of AIS Severely Errored Seconds in the last 15-minute period encountered by the interface. |
AISS 24 Hr Bucket | Number of AIS Severely Errored Seconds in the last 24-hour period encountered by the interface. |
UAS Current | Number of Unavailable Seconds encountered by the interface. |
UAS 15 Min Bucket | The number of Unavailable Seconds in the last 15-minute period encountered by the interface. |
UAS 24 Hr Bucket | Number of Unavailable Seconds in the last 24-hour period encountered by the interface. |
CCV Current | Number of C-Bit parity Code Violations encountered by the interface. |
CCV 15 Min Bucket | Number of C-Bit parity Code Violations in the last 15-minute period encountered by the interface. |
CCV 24 Hr Bucket | Number of C-Bit parity Code Violations in the last 24-hour period encountered by the interface. |
CES Current | The number of C-Bit parity Errored Seconds encountered by the interface. |
CES 15 Min Bucket | Number of C-Bit parity Errored Seconds in the last 15-minute period encountered by the interface. |
CES 24 Hr Bucket | Number of C-Bit parity Errored Seconds in the last 24-hour period encountered by the interface. |
CSES Current | Number of C-Bit parity Severely Errored Seconds encountered by the interface. |
CSES 15 Min Bucket | Number of C-Bit parity Severely Errored Seconds in the last 15-minute period encountered by the interface. |
CSES 24 Hr Bucket | Number of C-Bit parity Severely Errored Seconds in the last 24-hour period encountered by the interface. |
Percent LCV EFS | Percentage of seconds without any LCV Errors in the total elapsed seconds. |
There are four dialogs for monitoring Logical Ports on a FRSM 8T1 card:
Use the FR Port Monitor (Rcv) Counters dialog to monitor received FR port counters. (See Figure 13-5.)

The FR Port Monitor (Rcv) Counters dialog parameters are described in Table 13-7.
| Parameter | Description |
|---|---|
Rcv Port Frames | Number of frames received in the Ingress direction. |
Rcv Port Bytes | Number of bytes received in the Ingress direction. |
Rcv Port Frames DE | Number of frames with DE bit set received in the Ingress direction. |
Rcv Port Frames FECN | Number of frames with FECN bit set received in the Ingress direction. |
Rcv Port Frames BECN | Number of frames with BECN bit set received in the Ingress direction. |
Rcv Frames Disc CRC Err | Number of frames discarded on the Ingress due to CRC error. |
Rcv Frames Disc Alignment Err | Number of frames discarded on the Ingress due to alignment error. |
Rcv Frames Disc Illegal Len | Number of frames discarded on the Ingress due to illegal length. |
Rcv Frames Disc Illegal Hdr | Number of frames discarded on the Ingress due to illegal header. |
Rcv Frames Abort | Number of received frames aborted. |
Rcv Frames Unkn DLCI | Number of frames received with an unknown DLCI. |
Rcv Frames Last Unkn DLCI | Last unknown DLCI received. |
Rcv Frames Tagged FECN | Number of frames received that were tagged with FECN bit. |
Rcv Frames Tagged BECN | Number of frames received that were tagged with BECN bit. |
Rcv Frames Tagged DE | Number of frames received that were tagged with DE bit. |
Rcv Frames Disc DE Thresh Xceed | Number of frames discarded on the Ingress due to exceeded DE threshold. |
Rcv Port Kbps AIR | Received Average Information Rate in Kbps. |
Rcv Buf Not Available | Number of times the receiver is turned off. |
Rcv Frames Disc No | Number of times the receiver is turned off. |
Use the FR Port Monitor (Xmt) Counters dialog to monitor transmitted FR port counters. (See Figure 13-6.)

The FR Port Monitor (Xmt) Counters dialog parameters are described in Table 13-8.
| Parameter | Description |
|---|---|
Xmt Port Frames | Number of frames transmitted. |
Xmt Port Bytes | Number of bytes transmitted. |
Xmt Port Frames FECN | Number of frames transmitted with FECN bit set. |
Xmt Port Frames BECN | Number of frames transmitted with BECN bit set. |
Xmt Port Frames Disc Xceed Q Length | Number of frames discarded on the Egress due to exceeded queue length. |
Xmt Port Bytes Disc Xceed Q Depth | Number of bytes discarded on the Egress due to exceeded queue length. |
Xmt Port Frames during LMI Alarm | Number of frames transmitted during LMI logical port alarm. |
Xmt Port Bytes during LMI Alarm | Number of bytes transmitted during LMI logical port alarm. |
Xmt Frames abort | Number of transmit frames aborted. |
Xmt Frames Underrun | Number of frames discarded due to underrun. |
Xmt Port Kbps AIR | Transmit Average Information Rate in Kbps. |
Xmt Buf Not Available | Number of times the transmitter is turned off. |
Use the FR Port Monitor (ILMI/CLLM) Counters dialog to monitor FR port (ILMI/CLLM) counters. (See Figure 13-7.)

The FR Port Monitor (ILMI/CLLM) Counters dialog parameters are described in Table 13-9.
| Parameters | Description |
|---|---|
Row Status Inquiry | Number of Status Inquiry messages received. |
Rcv Invalid Req | Number of Invalid Request messages received. |
PCV VMI Seq Mismatch | Number of times UNI messages with sequence number mismatches were received. |
XMT Status | Number of times Status response messages were transmitted. |
XMT Asynch Update | Number of times Asynch Status messages were transmitted. |
UNI Signalling Timeout | Number of times UNI Status requests were not received. |
Xmt Status Inquiry | Number of Status Inquiry messages were transmitted. |
Row Status | Number of times Status response messages were received. |
RCV Asynch Update | Number of times Asynch Status messages were received. |
RCV NNI Seq Mismatch | Number of times NNI messages with sequence number mismatches were received. |
NNI Signalling Timeout | Number of times NNI Status requests were not received. |
RCV Frames CLLM | Number of CLLM frames received. |
Rcv Bytes CLLM | Number of CLLM bytes received. |
Xmt FRMS CLLM | Number of CLLM frames transmitted. |
Xmt Bytes CLLM | Number of CLLM bytes transmitted. |
CLLM Failures | Number of times an expected CLLM message was not received |
Use the ATM-ILMI Port RealTime Counters dialog to monitor ATM-ILMI port RealTime counters. The ATM-ILMI Port RealTime Counters dialog parameters are describe in Table 13-10.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Use the ATM RealTime Counters dialog to monitor ATM RealTime counters. (See Figure 13-8.)

The ATM RealTime Counters dialog parameters are described in Table 13-11.
| Parameter | Description |
|---|---|
Port Number | Port number. |
IngressRcvCells | Number of cells received in the Ingress direction. |
Ingress GFC Err Cells | Number of cells received in the Ingress direction with non-zero GFC. |
Ingress Vpi/Vci Err Cells | Number of cells received in the Ingress direction with unknown VPI/VCI. |
Egress Xmt Cells | Number of cells transmitted in the Egress direction. |
PortAlarm DiscCells | Number of cells discarded due to port alarm. |
Egress Xmt CLP Set cells | Number of cells transmitted in the Egress direction with CLP bit set. |
Egress Xmt EFCI Set cells | Number of cells transmitted in the Egress direction with EFCI bit set. |
Port Xmt AIS cells | Number of AIS cells transmitted towards the port. |
Port Xmt Segment Lpbk cells | Number of segment loopback cells transmitted in the Ingress direction. |
Port Rcv AIS Cells | Number of AIS cells received in the Ingress direction. |
Port Rcv FERF Cells | Number of FERF cells received in the Ingress direction. |
Port Rx Seg LpbkCells | Number of Segment Loopback cells received in the Ingress direction. |
Port Rcv CRC Err OAM Cells | Number of OAM cells received in the Ingress direction with CRC errors. |
ingrRcvCLPSetCells | Number of cells received from the port with the CLP bit in the ATM cell header equal to 1. |
ingrXmtCells | Number of cells out of the received cells from the port that were sent to the network. This count is taken after policing and Ingress queueing. |
egrRcvCells | Number of cells received from the network in the Egress direction. |
ingrRcvCellRate | Number of cells received per second from the port in the Ingress direction. |
ingrRcvUtilization | Percentage utilization of the port speed in the Ingress direction. |
egrXmtCellRate | Number of cells received transmitted to the port in the Egress direction. |
EgrXmtUtilization | Percentage utilization of the port speed in the Egress direction. |
EgrRcvCellRate | Number of cells received per second from the network in the Ingress receive direction. |
EgrRcvUtilization | Percentage utilization of the port speed in the Egress receive direction. |
totalIngrQfulldiscardCells | Total number of cells dropped on all the channels on this port because the Ingress Q was full. |
txFifoFullCnt | Number of times the AUSM card tries to send a cell but is unable to send because the Transmit FIFO is full. This is not the number of cells dropped. |
totalIngrClpSetDiscardCells | Total number of cells dropped on all the channels on this port with CLP bit set. |
Rcv Hec Err Cnt | Number of cells with HEC errors. |
Rcv Hec Err Sec Cnt | Number of seconds in which HEC errors were present. |
Rcv Hec Err SE Sec Cnt | Number of severely errored seconds in which HEC errors were present. |
Clear Port Counters? | Clears all ATM RealTime Counters for the port. |
There are four dialogs for monitoring channels on a FRSM VHS cards:
These dialogs are described in the sections that follow.
Use the FRSM Channel Counters (Rcv) dialog to monitor FRSM channel RCV counters. (See Figure 13-9.)
The FRSM Channel Counters (Rcv) dialog parameters are described in Table 13-12.
| Parameter | Description |
|---|---|
Rcv Frames | Number of frames received in the Ingress direction. |
Rcv Bytes | Number of bytes received in the Ingress direction. |
Rcv Frames DE | Number of DE frames received in the Ingress direction. |
Rcv Bytes DE | Number of DE bytes received in the Ingress direction. |
Rcv Frames Discard | Number of frames discarded in the Ingress direction. |
Rcv Bytes Discard | Number of bytes discarded in the Ingress direction. |
Rcv Frames Discard Shelf Alarm | Number of frames discarded in the Ingress direction due to Shelf alarm. |
Discarded Frames Xceed | Number of frames discarded in the Ingress direction due to exceeded queue depth. |
Discarded Bytes Xceed | Number of bytes discarded in the Ingress direction due to exceeded queue depth. |
Frames Disc Xceed | Number of frames discarded in the Ingress direction due to exceeded DE threshold. |
Rcv Frames FECN | Number of frames received with FECN bit already set. |
Rcv Frames BECN | Number of frames received with BECN bit already set. |
Rcv Frames Tagged FECN | Number of frames received that were tagged with FECN bit set. |
Rcv Frames Tagged BECN | Number of frames received that were tagged with BECN bit set |
Rcv Frames Tagged DE | Number of frames received that were tagged with DE bit set. |
Rcv Bytes Tagged DE | Number of bytes received that were tagged with DE bit set. |
Rcv Kbps AIR | Received Average Information Rate in Kbps. |
Rcv Frames Disc UPC | Number of frames discarded in the Ingress direction due to the UPC measurement in excess of CIR+EIR. |
Rcv Frames UnknownProtocols | Number of frames received with unknown protocols. Used only in Service Interworking (SIW) for PDUs that are dropped. |
Use the FRSM Channel Counters (XMT) dialog to monitor FRSM channel XMT counters. (See Figure 13-10.)

The FRSM Channel Counters (Xmt) dialog parameters are described in Table 13-13.
| Parameter | Description |
|---|---|
XMT Frames | Number of frames transmitted. |
Xmt Bytes | Number of bytes transmitted. |
Xmt Frames FECN | Number of frames transmitted with FECN bit already set. |
Xmt Frames BECN | Number of frames transmitted with BECN bit already set. |
Xmt Frames DE | Number of DE frames transmitted. |
Xmt Bytes DE | Number of DE bytes transmitted. |
Xmt Frames Discard | Number of frames discarded on the Egress. |
Xmt Bytes Discard | Number of bytes discarded on the Egress. |
Xmt Frames Xceed Q Depth | Number of frames discarded on the Egress due to exceeded queue length. |
Xmt Bytes Xceed Q Depth | Number of bytes discarded on the Egress due to exceeded queue depth. |
Xmt Frames Disc DE Thresh | Number of frames discarded on the Egress due to exceeded |
Xmt Frames Disc PhyLayer Fail | Number of frames discarded on the Egress due to physical layer failure. |
Xmt Frames Disc CRC Err | Number of frames discarded on the Egress due to CRC error. |
Xmt Frames Disc Reassm Fail | Number of frames discarded on the Egress due to reassembly failure. |
Xmt Frames Disc Src Abort | Number of frames discarded on the Egress due to source abort. |
Xmt Frames During | Number of frames transmitted during LMI logical port alarm. |
Xmt Bytes During | Number of bytes transmitted during LMI logical port alarm. |
Xmt Frames Tagged FECN | Number of frames transmitted that were tagged with FECN bit set. |
Xmt Frames Tagged BECN | Number of frames transmitted that were tagged with BECN bit set. |
Xmt Kbps AIR | Transmitted Average Information Rate in Kbps. |
Xmt Frames Tagged DE | Number of frames transmitted which have been DE tagged at the far end Ingress in excess of CIR. |
Xmt Bytes Tagged DE | Number of bytes transmitted which have been DE tagged at the far end Ingress in excess of CIR. |
Chan Sec Up Time | Number of seconds the PVC stay in service. |
Xmt Frames Invalid CPIs | Number of frames transmitted which have invalid CPI headers. |
Xmt Frames Length Violations | Number of frames transmitted with length violations. |
Xmt Frames OversizedSDUs | Number of frames transmitted with a size that is beyond the maximum. |
Xmt Frames UnknownProtocols | Number of frames transmitted with unknown protocols. Used only in Service Interworking (SIW) for PDUs that are dropped. |
Use the Channel SAR Counters dialog to monitor SAR channel counters. (See Figure 13-11.)

The Channel SAR Counters dialog parameters are described in Table 13-14.
| Parameter | Description |
|---|---|
Xmt Cells | Number of cells transmitted on this channel. |
Xmt Cells CLP | Number of CLP cells transmitted on this channel. |
Xmt Cells AIS | Number of AIS cells transmitted on this channel. |
Xmt Cells FERF | Number of FERF cells transmitted on this channel. |
Xmt Cells BCM | Number of BCM cells transmitted on this channel. |
Xmt Cells End2End Lpbk | Number of End2End loop cells transmitted on this channel. |
Xmt Cells Seg Lpbk | Number of segment loop cells transmitted on this channel. |
Rcv Cells | Number of cells received on this channel. |
Rcv Cells CLP | Number of CLP cells received on this channel. |
Rcv Cells AIS | Number of AIS cells received on this channel. |
Rcv Cells FERF | Number of FERF cells received on this channel. |
Rcv Cells BCM | Number of BCM cells received on this channel. |
Rcv Cells End2End Lpbk | Number of End2End cells received on this channel. |
Rcv Cells Seg Lpbk | Number of segment loop cells received on this channel. |
Rcv Cells Disc OAM | Number of cells that had CRC errors on OAM cells. |
Use the CESM Channel Counters dialog to monitor CESM channel counters. (See Figure 13-12.)

The CESM channel counters dialog parameters are described in Table 13-15.
| Parameter | Description |
Cells Played Out | Number of cells played out to T1/E1 interface. It excludes cells that were discarded for any reason. |
Cells Generated | Number of cells generated from the T1/E1 interface and sent towards the network. |
Hdr Errs | Number of AAL-1 header errors detected and possible corrected. Header errors include correctable and uncorrectable CRC, plus bad parity. |
Pointer Reframes | Number of events in which the AAL-1 reassembler found that an SDT pointer is not where it is expected and the pointer must be reacquired. |
Lost Cells | Number of cells lost in the Egress direction due to AAL-1 header errors and missing cells. |
Buf Underflows | Number of buffer underflows in the Egress direction. |
Buf Overflows | Number of buffer overflows in the Egress direction. |
Ingress Disc. Bytes | Number of bytes discarded due to shelf alarm in the Ingress direction from port data. |
Egress Underflow Cells | Number of cells inserted in case of Egress buffer underflow. |
Drop Bytes | Number of bytes discarded in the Egress direction because of Egress buffer overflow. |
Sequence Mismatch Cnt | Number of sequence mismatches. |
Use the ATM Line dialog to monitor ATM lines. (See Figure 13-13.)

The ATM Line dialog parameters are described in Table 13-15.
| Parameter | Description |
|---|---|
Total Rcv Cells | Number of cells received in the egress direction. |
Total XMT Cells | Number of cells transmitted in the egress direction. |
RcvHecError Cells | Number of cells with HEC error. |
Use the Broadband Interface dialog to monitor broadband interfaces. (See Figure 13-14.)

The Broadband Interface dialog parameters are described in Table 13-17.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Use the ILMI dialog to monitor ILMI. (See Figure 13-15.)

The ILMI dialog parameters are described in Table 13-18.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The SRM Counters dialog parameters are described in Table 13-19.
Parameter | Description |
|---|---|
|
|
|
|
The IMA Group Counters dialog parameters are described in Table 13-20.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Sep 29 13:08:15 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.