This chapter describes dialogs that show configuration information for:
Select the AUSM-B card to display AUSM-B card configuration dialogs by doing one of the following:
The AUSM-B Card Category menu contains the following items:
These dialogs are described in the sections that follow.
Use the Card Configuration dialog to view AUSM-B card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 2-1.

| Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Use this dialog to view service module features for the AUSMB card. (See Figure 2-2)

| Parameter | Description |
|---|---|
Card Supports Foresight? | BRAM parameter indicating whether this card will support ForeSight. Can be rateControlEnabled or rateControlDisabled. |
IMA Allowed? | Whether IMA groups are allowed on this card. Can be (1) imaDisabled or (2) imaEnabled. |
Use the ATM Port RealTime Counters dialog to view ATM port RealTime counters information. The ATM Port RealTime Counters dialog parameters are described in Figure 2-3.

The ATM Port RealTime Counters dialog parameters are described in Table 2-3.
| Parameter | Description |
|---|---|
Port Number | Port Number. |
IngressRcvCells | Total number of cells received in the Ingress direction. |
Ingress GFC Err Cells | Ingress Generic Flow Control error cells. |
Ingress Vpi/Vci Err Cell | Ingress Vpi/Vci error cells. |
Ingress Unknown Vpi/Vci | Total number of cells received in the Ingress direction with unknown VPI/VCI. |
Egress Xmt Cells | Total number of cells transmitted in the Egress direction. |
PortAlarm DiscCells | Total number of cells transmitted in the Egress direction. |
Egress Xmt CLP Set Cells | Total number of cells transmitted in Egress with CLP bit set. |
Egress Xmt EFCI Set Cells | Total number of cells transmitted in Egress with EFCI bit set. |
Port Xmt AIS cells | Total number of AIS cells transmitted towards the port. |
Port Xmt Segment Lpbk cells | Total number of Segment Loopback cells transmitted towards the port. |
Port Rcv AIS cells | Total number of AIS cells received in the Ingress direction. |
Port Rcv FERF cells | Total number of FERF cells received in the Ingress direction. |
Port Rcv Segment Lpbk cells | Total number of segment loopback cells received in the Ingress direction. |
Port Rcv CRC Err OAM cells | Total number of CRC Err OAM cells received in the Ingress direction. |
ingrRcvCLPSetCells | Total number of CLP Set cells received in the Ingress direction. |
ingrXmtCells | Total number of Xmt cells transmitted in the ingress direction |
egrRcvCells | Total number of cells transmitted in the Egress direction |
ingrRcvCellRate | Rate at which cells are received in the Ingress direction |
ingrRcvUtilization | Number of cells received per second from the port in the ingress direction. Maximum value is 5000 because clear E1 rate is 4830. |
egrXmtCellRate | Rate at which XMT cells are transmitted in the Ingress direction |
egrXmtUtilization | Percentage utilization of the port speed in the egress direction. |
egrRcvCellRate | Rate at which cells are received in the egress direction |
egrRcvUtilization | Percentage utilization of the port speed in the egess receive direction. |
totalIngrQfulldiscardCells | Total number of cells dropped on all the channels on this port because the ingress Q was full. Adds up all the IngressQfull discard per channel statistics for all the channels in the port. |
txFifoFullCnt | provides a count of the number of times the AUSM-B card tried to send a cell, but was unable to send because the Transmit FIFO was full. Note that this is NOT a count of the number of cells dropped. This statistics is per card statistics. This counter is duplicated in channel count group to help monitoring. |
totalIngrClpSetDiscardCells | Total number of cells with CLP=1 dropped on all the channels on this port because of either PCR Exceeded, SCR exceeded (with CLP tagging disabled) or CLP Hysteris. Adds up all the IngressClpSet discard per channel statistics for all the channels in the port. |
Rcv Hec Err Cnt | Number of HEC errored cells received on all the links currently in the group. This object does not have any default value. |
Rcv Hec Err Sec Cnt | Number of seconds in which at least one link in the IMA group experienced a HEC error. |
Rcv Hec Err SE Sec Cnt | Number of severely errored seconds received on all the links currently in the IMA group. |
Clear Port Counters? | Clears all Port Counters. Choose noAction or resetCounters form the popup menu. |
Use the LCN Partition Type dialog to configure LCN partition type on a AUSM-B card. (See Figure 2-4.)

Choose one from the cardLcnPartitionType pull-down menu:
|
|
|
|
|
|
To modify LCN partition type, make the changes you want and click Modify.
There are two dialogs for configuring ports on an AUSM-B card:
These dialogs are described in the sections that follow.
Use the Card/Ports (ATM) dialog to configure ATM Ports on an AUSM-B card. (See Figure 2-5.)

The Card/Ports (ATM) dialog parameters are described in Table 2-4.
| Parameter | Description |
|---|---|
Port No. | Logical port number. |
Line No. | Line number. |
Port Enable | Port enabled status. Choose enable or disable from the popup menu. |
Port State | Logical port state. Can be:
|
Clear Port Counters | Port speed. Choose noAction or resetCounters from the popup menu. |
Clear Port ILMI Counters | Number of flags transmitted between frame relay frames. Choose noAction or resetCounters from the popup menu. |
Port Oversubscribed | Number of times queue 1 is serviced for every time queue 2 is serviced. |
Port Type | Port type. Choose one from the popup menu:
|
Port Interface Type | Port interface type. |
Port Speed (Cells Per Sec) | Port speed in Kbps. |
Cell Framing | Indicates the supported cell framing type. Choose one from the popup menu:
|
Cell Scramble | Indicates whether or not cell scrambling is required. Choose noScramble or scramble from the popup menu. |
Single Bit ErrCorrection | Single bit error correction line status. Choose disable or enable from the popup menu. Disable is the default. |
Port Signalling Protocol Type | Port signalling protocol. Choose one from the popup menu:
|
Port Signalling Vpi | VPI on which signalling cells arrive. |
Port Signalling Vci | VCI on which signalling cells arrive. |
ILMI Trap Enable | ILMI trap enabled status. Choose disable or enable from the popup menu. |
Min Trap Interval (Secs) | Number of seconds between traps. |
Keep Alive Polling Enable | Keep alive polling enabled status. Choose disable or enable from the popup menu. |
Error Threshold | Error threshold. |
Event Threshold | Event threshold. |
Polling Interval (Secs) | Polling interval. Choose one from the popup menu:
|
Min Enquiry Interval (Secs) | Minimum enquiry interval. |
Use the Cards/Ports (Forum Compliant IMA Groups) dialog to configure Forum Compliant IMA Ports on an AUSM-B card. (See Figure 2-6.)

The Cards/Ports (Forum Compliant IMA Groups) dialog parameters are described in Table 2-5.
| Parameter | Description |
|---|---|
IMAPort Num | IMA port number. Choose onenoAction or resetCounters from the popup menu. |
IMAPort State | IMA Port State. Choose onenoAction or resetCounters from the popup menu. |
IMAPort Enable | Modifies, enables, or disables the configuration of the port. Choose one from the popup menu:
|
IMAPort Speed(Cells per Sec.) | Speed of the port in cells per second. |
Num. Links in Group | Number of links configured in the IMA group. |
List of Links In Group | List of links in the IMA group delimited by dots. |
Period LCP Cells Tx (Cells) | Period at which LCP cells of the IMA protocol can be transmitted. A value of 32 indicates that after 32 cells, one LCP cell is transmitted on that link of the IMA group. Currently, the only value supported is 128. |
Max. Tolerable Diff. Delay(Milli Secs) | Indicates the maximum tolerable differential delay in milliseconds between the various links in the IMA group. |
IMA Port Type | Indicates whether or not the port is to be configured for UNI/NNI/STI mode. Choose one from the popup menu:
|
AxisImaGroupTxAvailCellRate | Current cell rate (truncated value in cells per second) provided by the IMA group in the transmit direction, considering all the transmit links in the active state. |
AxisImaGroupSymmetry | Symmetry of the IMA group. Choose symmetricOperation. |
AxisImaGroupMinNumRxLinks | Minimum number of receive links required to be active for the IMA group to be in the Up state. At present since only symmetric configuration is supported, this should be equal to axisImaGroupMinNumTxLinks. |
AxisImaGroupNetTxClkMode | Transmit clocking mode used by the near-end IMA group. Choose ctc or itc from the popup menu. |
AxisImaGroupNumRxCfgLnks | Number of links that are configured to receive in this IMA group. |
AxisImaGroupTestLinkIfIndex | Designates an interface as the test link. A value of -1 specifies that the implementation may choose the test link. In this case, the implementation may also choose the value of axisImaGroupTestPattern. |
AxisImaGroupTestPattern | Specifies the test pattern in an IMA group loopback operation. A value in the range 0 to 255 designates a specific pattern. A value of -1 specifies that the implementation may choose the value. In this case, the implementation may also choose the value of axisImaGroupTestLinkIfIndex. |
AxisImaGroupTestProcStatus | Used to enable or disable the Test Pattern Procedure, and to note whether at least one link failed the test. |
AxisImaGroupIntegrationUpTime | Integration up time for alarm integration. |
AxisImaGroupIntegrationDownTime | Integration down time for alarm integration. |
To modify the parameters, make the changes you want and click Modify.
Use the ATM Signalling dialog to view and ATM Signalling information. (See Figure 2-7.)

| Parameter | Description |
|---|---|
SigPortNum | Port number in the range 1-4 for a four port card, 1-8 for an eight port card |
Port Signalling Protocol Type | Signalling type: 1 (other), 2 (no signalling), or 3 (ILMI). |
Port Signalling Vpi | Virtual path identifier in the range 0 - 259. |
Port Signalling Vci | Virtual circuit identifier in the range 0 - 65535. |
ILMI Trap Enable | Takes two values: 1 (disable), or 2 (enable). |
Min. Trap Interval (Secs) | The range of 1 - 10 seconds. |
Keep Alive Polling Enable | Takes two values: 1 (disable), or 2 (enable). |
Error Threshold | Error threshold (N491) value1..10. |
Event Threshold | Event threshold (N492) value1..10. |
Polling Interval (Secs) | Polling interval (T493) value in 5 second increments 5..60 (e.g. 5, 10, 15). |
Min. Enquiry Interval (Secs) | Minimum enquiry interval (T493) value 1..20. |
Use the Card/Channels dialog to configure channels on an AUSM-B card. (See Figure 2-8).

The AUSM-B Channels dialog parameters are described in Table 2-7.
| Parameter | Description |
|---|---|
Channel No. | Virtual connection number. |
Channel Row Status | Channel status. Choose one from the popup menu:
|
Clear Channel Counters | Resets all the counters. Choose noAction or resetCounters from the popup menu. |
Channel Conn Type | Connection type. Choose vpc or vcc from the popup menu. |
Channel Service Type | Service type. Choose one from the popup menu:
|
Channel Conn Descr. | Description of the connection. |
Channel Conn Type | Connection type. Choose vpc or vcc from the popup menu. |
Channel Port No. | Logical port on the board to which the logical channel is associated. |
Channel VPI | VPI value for the channel. |
Channel VCI | VCI value for the channel. |
Channel Egress Q Select | Select one out of the 16 possible queues. Each queue may have a different service algorithm. |
Ingress Q Depth | Sets the maximum depth for Queue before it starts dropping the cells. In AUSM-B, the valid range is from 1..8000. |
High Threshold for Dropping CLP | Sets the higher threshold for dropping CLP set cells in the Ingress direction. In AUSM-B, the valid range is from 1..8000. |
Low Threshold for Dropping CLP | Sets the lower threshold for dropping CLP set cells in the Ingress direction. In AUSM-B, the valid range is from 1..8000. |
Channel CLP State | CLP state for the channel. Can be low or high. |
Channel EFCI Threshold | Sets the EFCI threshold value for setting EFCI bit in the Ingress direction. In AUSM-B, the valid range is from 1..8000. |
Ingress UPC Enable? | Enables and disables UPC for the Ingress cells. Choose disable or enable from the popup menu. |
PCR for CLP (0+1) Cells | Peak Cell Rate for CLP [0+1] cells. The actual value depends on the speed of the logical port [T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal), or IMA E1 (clear)]. The IMA port's speed is variable and depends on the number of links in the port. In AUSM-B (4-port card), the maximum value is 4830. |
Compliant Information Rate (CPS) | Complaint Information Rate. The actual value depends on the speed of the logical port [T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal), or IMA E1 (clear)]. The IMA port's speed is variable and depends on the number of links in the port. In AUSM-B (4-port card), the maximum value is 4830. |
Compliant CDV For Cells (Micro Secs) | Complaint Cell Delay Variation for all cells. |
Compliant Burst Size | Complaint Burst Size. |
Initial Burst Size | Initial Burst Size. |
Max Frame Size | Maximum Frame Size. |
SCR Policing | Selects SCR policing for CLP=0 or all cells. Choose one from the popup menu:
|
PCR for CLP=0 Cells | Peak Cell Rate for CLP=0 cells. The actual value depends on the speed of the logical port, which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal), or IMA E1 (clear) port. The IMA port's speed is variable and depends on the number of links in the port. In AUSM-B, the maximum value is 4830. |
Compliant CDV for CLP=0 Cells | Complaint Cell Delay Variation for CLP=0 cells. |
Enable/Disable CLP Tagging | Used to enable or disable CLP tagging for Ingress cells. |
Enable/Disable Frame Based GRCA | Used to enable or disable Frame based GCRA. |
Enable/Disable Foresight | Used to enable or disable Foresight. |
Min. Information Rate (CPS) | Minimum Information Rate. The actual value depends on the speed of the logical port, which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal), or IMA E1 (clear) port. The IMA port's speed is variable and depends on the number of links in the port. In AUSM-B , the maximum value is 4830. |
Peak Information Rate (CPS) | Peak Information Rate. The actual value depends on the speed of the logical port, which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal), or IMA E1 (clear) port. The IMA port's speed is variable and depends on the number of links in the port. In AUSM-B, the maximum value is 4830. |
Quiescent Information Rate (CPS) | Quiescent Information Rate. The actual value depends on the speed of the logical port, which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal), or IMA E1 (clear) port. The IMA port's speed is variable and depends on the number of links in the port. In AUSM-B, the maximum value is 4830. |
Enable/Disable Remote Lpbk | Enables or disables the remote loopback for each channel. When you enable this option on a connection (channel), all the cells that are coming from the network side would be lopped back toward the network and all the frames coming from the user side would be dropped. Choose disable or enable from the popup menu. |
Test Type | Choose one from the popup menu:
The chanTestType starts testing the continuity or delay of a connection. It sends specific cell patterns toward the network and the terminating end of this connection has to be an AXIS or ASI of a BPX in order for this test to be working. The receiving node would loop back when it receives these cells. The test should be complete in about a couple of seconds. To test the delay, follow these steps: 1. Set Channel Test Type to testdelay. 2. Read Channel Test State until it is "Pass" or "Fail." 3. Read Round Trip Delay for the delay if it is "Pass." The chanTestType will return to "notest" when the test is completed. To test the continuity, follow these steps: 1. Set Channel Test Type to testcon. 2. Read Channel Test State until it is "Pass" or "Fail." You cannot select two tests back-to-back. You must select test and wait for the result before starting the other test. |
Test State | State of the test. Choose one from the popup menu:
|
Round Trip Delay (Milli. Sec) | Round trip delay in milliseconds. When chanTestType is testdelay, the result of the test can be read in chanRTResult. |
Test Type CPE Side | ChanTestType starts testing the segment continuity of a connection. It sends OAM Segment Loopback cells towards the port side (CPE). The CPE loops back the cell. Choose testconseq or notest from the popup menu. Notest is the default. To test the continuity, follow these steps: 1. Set chanTestTypeCPESide to "testconseq." 2. Read chanTestState until it is "Pass" or "Fail." chanTestType returns to "notest" when the test is completed. |
Test State CPE Side | State of the test. Choose one from the popup menu:
|
Ingress Percent Util | Percentage utilization of the IngrService Rate, used for connection admission control. |
Egress Percent Util | Percentage utilization of the EgrService Rate, used for Egress bandwidth calculation and connection admission control. |
Egress Service Rate | Used for Egress bandwidth calculation and for connection admission control. The actual value depends on the speed of the logical port, which can be a T1, E1 (normal), E1 (clear), IMA T1, IMA E1 (normal), or IMA E1 (clear) port. The IMA's port speed is variable and depends on the number of links in the port. In AUSM-B, the maximum value is 4830. |
Oversubscribe Override | Allows you to add a new connection on a port, even if it is oversubscribed. Choose disable or enable from the popup menu. |
Local VP ID | Every VP connection will have a unique VP ID of between 1 and 340. This is sent to ASC at the time of VP connection setup. This number, along with the slot number, forms a number that is unique across the shelf. This will be set only when adding the connection. The range varies, depending on the BNM interface: STI 1..100UNI 1..20NNI 1..340AUSM-B-4P 1..255 |
Enable/Disable RM Cells | Enables and disables the sending of Resource Management Cells. Choose disable or enable from the popup menu. |
Ingress Discard Option | Enables and disables the sending of Resource Management Cells. Choose disable or enable from the popup menu. |
CDR Number | Key to correlate cell/frame counts, start/end record. |
To modify the parameters, make the changes you want and click Modify.
There are four ways to select the line (from either the front or rear view of the card) to display the dsx1 line configuration dialogs:
The categories of line configuration for dsx1 lines are:
Use the Physical Line Config (dsx1) dialog to view and configure the dsx1 physical line information. (See Figure 2-9.)

The Physical Line Config (dsx1) dialog parameters are described in Table 2-8.
| Parameter | Description |
|---|---|
Line Number | Line number. |
Type | Line type. Choose one from the popup menu:
|
Connector | Line connector type and the back card type. Can be one of the following:
|
Line Enable | Line enabled status. Choose one from the popup menu:
|
Coding | Type of zero code suppression used on the line, which affects a number of its characteristics. Choose one popup menu:
JBZS = Jammed Bit Zero Suppression |
Length | Line length. Choose one from the popup menu:
|
Xmt Clock | Transmit clock source. Choose one from the popup menu:
On a CESM card, only localTiming is supported. |
Loopback | Line loopback configuration of the DS1 interface. Choose one of the following from the popup menu:
|
Code Sent | Type of code sent across DS1. Choose one from the popup menu:
|
DS0's Used | DS0s used for this line. |
Loopback code Detect | Indicates whether or not detection of line loopback codes is enabled. Choose codeDetectDisabled or codeDetectEnabled from the popup menu. |
Enable BERT | Indicates whether or not BERT is enabled. Choose disabled or enabled from the popup menu. |
To modify the parameters, make the changes you want and click Modify.
Use the Physical Line Alarm Config (dsx1) dialog to view and configure the dsx1 physical line alarm information. (See Figure 2-10.)

The Physical Line Alarm Config (dsx1) dialog parameters are described in Table 2-9.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To modify the parameters, make the changes you want and click Modify.
Use the Dsx1 Line RealTime Counters dialog to view and configure the dsx1 RealTime counters. (See Figure 2-11.)

The dSX1 Line RealTime Counters dialog parameters are described in Table 2-10.
Parameter | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
To modify the parameters, make the changes you want and click Modify.
Use the IMA Alarm Configuration dialog to view and configure IMA alarms. (See Figure 2-12.)
The IMA Alarm Configuration dialog parameters are described in Table 2-11.
Use the IMA Alarms dialog to view and configure IMA alarms information. (See Figure 2-13.)

The IMA Alarms dialog parameters are described in Table 2-12.
There are five dialogs for logical port configuration on an AUSMB Card.
Use the Logical Port Config dialog to view and configure logical ports information. (See Figure 2-14.)

| Parameter | Description |
|---|---|
Port No. | A logical port number. In AUSM (4-port card), a logical port is the same as a physical port. |
Line No. | Identifies the physical line number associated with the logical port. In AUSM cards, the line number and logical port number can be different. An AUSM 4 port card will have the same numbers. |
Port Enable | Value 1 disables the port, value 2 enables the port. |
Port State | 1) Not configured 2) Active 3) Remote loopback 4) Line failure 5) Signalling failure 6) Out of cell delineation 7) Local loopback |
Port Type | Indicates whether the interface is UNI, or NNI. |
Port Interface Type | The integer value corresponds to the interface type: (1) unknown, (2) t1, or (3) e1. |
Port Speed (Cells Per Sec) | The speed of the port. |
Single Bit ErrCorrection | Turns on or off single bit error correction for the specified line.Values are 1) Disable or 2) Enable (the default is disable). |
Clear Port Counters? | Resets all counters. Values are 1) noAction and 2) resetCounters. |
Use the ATM Signalling dialog to view and ATM Signalling information. (See Figure 2-15.)

| Parameter | Description |
|---|---|
SigPortNum | Port number in the range 1-4 for a four port card, 1-8 for an eight port card |
Port Signalling Protocol Type | Signalling type: 1 (other), 2 (no signalling), or 3 (ILMI). |
Port Signalling Vpi | Virtual path identifier in the range 0 - 259. |
Port Signalling Vci | Virtual circuit identifier in the range 0 - 65535. |
ILMI Trap Enable | Takes two values: 1 (disable), or 2 (enable). |
Min. Trap Interval (Secs) | The range of 1 - 10 seconds. |
Keep Alive Polling Enable | Takes two values: 1 (disable), or 2 (enable). |
Error Threshold | Error threshold (N491) value1..10. |
Event Threshold | Event threshold (N492) value1..10. |
Polling Interval (Secs) | Polling interval (T493) value in 5 second increments 5..60 (e.g. 5, 10, 15). |
Min. Enquiry Interval (Secs) | Minimum enquiry interval (T493) value 1..20. |
Address Registration | Value 1 enables address registration while 2 disables address registration. |
Clear Port ILMI Counters? | Values are noAction and resetCounters which clears all ILMI counters. |
To view and configure ATM RealTime counters, select ATM RealTime Counters from the Category pull-down menu. The parameters are described in Table 2-15.
| Parameter | Description |
|---|---|
Port Number | Logical port number. |
IngressRcvCells | Number of cells received in the Ingress direction. |
Ingress GFC Err Cells | Number of cells received in Ingress direction with non zero-GF. |
Ingress Vpi/Vci Err Cells | Number of cells received in Ingress direction with unknown Vpi/Vci. |
Ingress UnknownVpi/Vci | Last unknown Vpi/Vci value. |
Egress Xmt Cells | Number of cells transmitted in the egress direction. |
PortAlarm DiscCells | Number of cells discarded due to port alarm. |
Egress Xmt CLP set cells | Number of cells transmitted in Egress direction with CLP bit set. |
Egress Xmt EFCI set cells | Number of cells transmitted in Egress direction with EFCI bit set. |
Port Xmt AIS cells | Number of AIS cells transmitted towards port. |
Port Xmt Segment Lpbk cells | Number of Segment Loopback cells transmitted towards port. |
Port Rcv AIS cells | Number of AIS cells received in Ingress direction. |
Port Rcv FERF cells | Number of FERF cells received in Ingress direction. |
Port Rcv Segment Lpbk cells | Number of Segment Loopback cells received in Ingress direction. |
Port Rcv CRC Err OAM Cells | Number of OAM cells received in Ingress direction with CRC error. |
ingrRcvClpSetCells | Number of cells received from the port which had the CLP bit in the ATM cell header equal to 1. |
ingrXmtCells | Number of cells received from the port that were sent to the network. This count is taken after policing and ingress queueing. |
egrRcvCells | Number of cells received from the network in the egress direction. |
ingrRcvCellRate | Number of cells received per second from the port in the ingress direction. Maximum value is 5000 because clear E1 rate is 4830. |
ingrRcvUtilization | Percentage utilization of the port speed in the ingress direction. |
egrXmtCellRate | Number of cells transmitted to the port in the egress direction. |
egrXmtUtilization | Percentage utilization of the port speed in the egress direction. |
egrRcvCellRate | Number of cells received per second from the network in the egress receive direction. |
egrRcvUtilization | Percentage utilization of the port speed in the egress receive direction. |
totalIngrQfulldiscardCells | Total number of cells dropped on all the channels on this port because the ingress Q was full. Adds up all the IngressQfull discard per channel statistics for all the channels in the port. |
txFifoFullCnt | Count of the number of times the AUSM card tried to send a cell, but was unable to send because the Transmit FIFO was full. Note that this is NOT a count of the number of cells dropped. This statistics is per card statistics. This counter is duplicated in channel count group to help monitoring. |
totalIngrClpSetDiscardCells | Total number of cells with CLP=1 dropped on all the channels on this port because of either PCR Exceeded, SCR exceeded (with CLP tagging disabled), or CLP Hysteris. |
Rcv Hec Err Cnt | Number of cells with HEC error. |
Rcv Hec Err Sec Cnt | Number of seconds in which HEC error was there. |
Rcv Hec Err SE Sec Cnt | Number of Severely errored seconds. |
Clear Port Counters? | Resets all the counters. |
Use the ATM Interface Resource Partitions dialog to view ATM Interface Resource Partitions information. (See Figure 2-16.)

| Parameter | Description |
|---|---|
bbRscPartIFNum | Broadband Interface resource number, a logical interface number. |
bbRscPartCtrlrNum | Index for the controller for this logical interface:
|
bbIfRscPrtRowStatus | Used to add, modify, or delete a port. The default is delete. |
bbIfRscPrtIngrPctBandwidth | Percentage of logical interface Ingress bandwidth available for UNI channels. Default is 0% |
bbIfRscPrtEgrPctBandwidth | Percentage of logical interface Egress bandwidth available for UNI channels. Default is 0% |
bbIfRscPrtVpiLow | Beginning of the VPI range reserved for this partition. For VPI connections the valid VPI values are 0 to 4095. |
bbIfRscPrtVpiHigh | End of the VPI range reserved for this partition. For VPI connections the valid VPI values are 0 to 4095. |
bbIfRscPrtVciLow | Beginning of the VCI range reserved for this partition. For VCI connections the valid VCI values are 0-4095. |
bbIfRscPrtVciHigh | End of the VCI range reserved for this partition. For VCI connections the valid VCI values are 0-4095. |
bbIfRscPrtMaxChans | The maximum number of channels for a port. |
To view and configure ATM port resource partitions, select ATM Port Resource Partitioning from the Category pull-down menu. The parameters are described in Table 2-17.

| Parameter | Description |
|---|---|
ausmResPartPortNum | Logical port number. |
ausmPortSvcInUse | Indicates whether the resources have been partitioned. Choose one from the popup menu:
The default value is NotInUse. |
ausmPortSvcShareLcnVpid | Indicates whether or not the LCN and VPid address spaces are shared across all the ports.
|
ausmPortSvcLcnLow | Beginning of the LCN range reserved for SVCs. This value applies to all ports when atmPortSvcShareLcnVpid is set to cardBased. |
ausmPortSvcLcnHigh | End of the LCN range reserved for SVCs. |
ausmPortSvcVpidLow | Beginning of the VPID range reserved for SVCs. Both the VPID low and high values apply to all ports when the atmPortSvcShareLcnVpid object is set to cardBased. |
ausmPortSvcVpidHigh | End of the VPID range reserved for SVCs. For VPI connections the valid VCI values are 0 to 4095. |
ausmPortSvcVciLow | Beginning of the VCI range reserved for SVCs. Both the VCI low and high values apply to all ports when the atmPortSvcShareLcnVpid object is set to cardBased. |
ausmPortSvcVciHigh | End of the VCI range reserved for SVCs. For VCI connections the valid VCI values are 0-4095. |
egrXmtCellRate | Number of cells transmitted to the port in the egress direction. |
egrXmtUtilization | Percentage utilization of the port speed in the egress direction. |
egrRcvCellRate | Number of cells received per second from the network in the egress receive direction. |
egrRcvUtilization | Percentage utilization of the port speed in the egress receive direction. |
totalIngrQfulldiscardCells | Total number of cells dropped on all the channels on this port because the ingress Q was full. Adds up all the IngressQfull discard per channel statistics for all the channels in the port. |
txFifoFullCnt | Number of times the AUSM card tried to send a cell, but was unable to send because the Transmit FIFO was full. Note that this is NOT a count of the number of cells dropped. This statistics is per card statistics. This counter is duplicated in channel count group to help monitoring. |
totalIngrClpSetDiscardCells | Total number of cells with CLP=1 dropped on all the channels on this port because of either PCR Exceeded, SCR exceeded (with CLP tagging disabled) or CLP Hysteris. |
Rcv Hec Err Cnt | Number of HEC errored cells received on all the links currently in the IMA group. |
Rcv Hec Err Sec Cnt | Number of HEC errored seconds for the IMA groupthat is, the number of seconds in which at least one link in the IMA group experienced a HEC error. |
Rcv Hec Err SE Sec Cnt | Number of severely errored seconds received on all the links currently in the IMA group. |
Clear Port Counters? | Values are noAction and resetCounters which clears all port counters. |
There are five dialogs for IMA port configuration on an AUSMB Card.
Use the Logical Port Configuration (Forum Compliant IMA Groups) dialog to view and configure IMA logical ports. (See Figure 2-18.)

The Logical Port Configuration (Forum Compliant IMA Groups) parameters are described in Table 2-18.
| Parameter | Description |
|---|---|
IMAPort Num | Logical port number. |
IMAPort State | IMA port state. |
IMAPort Enable | Enables, disables or modifies the configuration of the port. Choose one from the popup menu: delportDisables the entire IMA group. addportEnables the IMA group. addlinksAdds links to an existing IMA group. Use this selection to increase the bandwidth. dellinksDeletes links from an existing IMA group. Use this selection to decrease the bandwidth. modifyModifies parameters, other than links in an existing IMA group. An IMA group is synonymous with an IMA port. To configure an IMA port, the different lines in the IMA port should be enabled and then the IMA port should be added. |
IMAPort Speed (Cells per Sec) | Speed of the port in cells per second. This depends on the number of links in the IMA group and the configuration of the physical interface on each link. |
Num Links In Group | Number of links configured in the IMA group. |
List of Links in Group | List of links in the IMA group delimited by dots. |
Period LCP Cells Tx (Cells) | Period at which LCP cells of the IMA protocol can be transmitted. A value of 32 indicates that after 32 cells, one LCP cell is transmitted on that link of the IMA group. Currently, the only value supported is 128. |
Max. Tolerable Diff. Delay | Indicates the maximum tolerable differential delay in milliseconds between the various links in the IMA group. |
IMA Port Type | Indicates whether the port is to be configured for UNI/NNI/STI mode. STI mode is supported only in the case of IMATM. vpTrkUni should be used only in IMATM when virtual trunks are passing through IMATM (in other words, when the cell format is UNI but ForeSight information is carried in the lower 16 bits). Choose one from the popup menu:
|
axisImaGroupTxAvailCellRate | Current cell rate (truncated value in cells per second) provided by the IMA group in the transmit direction, considering all the transmit links in the Active state.
|
axisImaGroupSymmetry | Symmetry of the IMA group. Choose one from the popup menu:
|
axisImaGroupMinNumRxLinks | Minimum number of receive links required to be active for the IMA group to be in the Up state. At present since only symmetric configuration is supported, this should be equal to axisImaGroupMinNumTxLinks. |
axisImaGroupNeTxClkMode | Transmit clocking mode used by the near-end IMA group. Choose one from the popup menu:
|
axisImaGroupNumRxCfgLnks | Number of links that are configured to receive in this IMA Group. |
axisImaGroupTestLinkIfIndex | Designate an interface as the test link. A value of -1 specifies that the implementation may choose the test link. In this case,the implementation may also choose the value of axisImaGroupTestPattern. |
axisImaGroupTestPattern | Specifies the test pattern in an IMA group loopback operation. A value in the range 0 to 255 designates a specific pattern. A value of -1 specifies that the implementation may choose the value. In this case, the implementation may also choose the value of axisImaGroupTestLinkIfIndex. |
axisImaGroupTestProcStatus | Used to enable or disable the Test Pattern Procedure and notes. The test is started by setting operating status. If any link should fail the test, the IMA will set the status to linkfail. The linkfail state will persist until either the disabled state is set or until no instance of imaLinkTestProcStatus has the value linkfail. |
axisImaGroupIntegrationUpTime | Integration UP time in milliseconds for alarm integration. |
axisImaGroupIntegrationDownTime | Integration DOWN time milliseconds for alarm integration. |
axisImaGroupMinNumTxLinks | Minimum number of transmit links required to be active for the IMA group to be in the Up state. Even though the range is 1..8, this value should be equal to the maximum number of configured links in IMA group. |
Use the Logical Port State Config (Forum Compliant IMA Groups) dialog to view and configure IMA compliant logical port state information. (See Figure 2-19.)

The Logical Port State Config (Forum Compliant IMA Groups) dialog parameters are described in Table 2-19.
Use the ATM Signalling dialog to view and ATM Signalling information. (See Figure 2-20.)

| Parameter | Description |
|---|---|
sigPortNum | Port number in the range 1-4 for a four port card, 1-8 for an eight port card |
Port Signalling Protocol Type | Signalling type: 1 (other), 2 (no signalling), or 3 (ILMI). |
Port Signalling Vpi | Virtual path identifier in the range 0 - 259. |
Port Signalling Vci | Virtual circuit identifier in the range 0 - 65535. |
ILMI Trap Enable | Takes two values: 1 (disable), or 2 (enable). |
Min. Trap Interval (Secs) | The range of 1 - 10 seconds. |
Keep Alive Polling Enable | Takes two values: 1 (disable), or 2 (enable). |
Error Threshold | Error threshold (N491) value1..10. |
Event Threshold | Event threshold (N492) value1..10. |
Polling Interval (Secs) | Polling interval (T493) value in 5 second increments 5..60 (e.g. 5, 10, 15). |
Min. Enquiry Interval (Secs) | Minimum enquiry interval (T493) value 1..20. |
Address Registration | Value 1 enables address registration while 2 disables address registration. |
Clear Port ILMI Counters? | Values are noAction and resetCounters which clears all ILMI counters. |
Use the IMA RealTime Counters dialog to view and configure IMA RealTime counters. (See Figure 2-21.)

The parameters are described in Table 2-21.
| Parameter | Description |
|---|---|
imaCntPortNum | Logical port number. |
rcvAcpCells | Number of ACP cells received. |
xmtAcpCells | Number of ACP cells transmitted on this IMA group. |
xmtAcpCellsMissed | Number of ACP cells that could not be transmitted on this IMA group due to lack of resources (buffers). |
Rcv HEC Err Count | Number of HEC errored cells received on all the links currently in the IMA group. |
Rcv HEC Err Sec Count | Number of HEC errored seconds for the IMA group-- that is, the number of seconds in which at least one link in the IMA group experienced a HEC error. |
Rcv HEC Err Severe Sec Count | Number of severely errored seconds received on all the links currently in the IMA group. |
To view and configure ATM RealTime counters, select ATM RealTime Counters from the Category pull-down menu. The parameters are described in Table 2-22.
| Parameter | Description |
|---|---|
Port Number | Logical port number. |
IngressRcvCells | Number of cells received in the Ingress direction. |
Ingress GFC Err Cells | Number of cells received in Ingress direction with non zero-GF. |
Ingress Vpi/Vci Err Cells | Number of cells received in Ingress direction with unknown Vpi/Vci. |
Ingress UnknownVpi/Vci | Last unknown Vpi/Vci value. |
Egress Xmt Cells | Number of cells transmitted in the egress direction. |
PortAlarm DiscCells | Number of cells discarded due to port alarm. |
Egress Xmt CLP set cells | Number of cells transmitted in Egress direction with CLP bit set. |
Egress Xmt EFCI set cells | Number of cells transmitted in Egress direction with EFCI bit set. |
Port Xmt AIS cells | Number of AIS cells transmitted towards port. |
Port Xmt Segment Lpbk cells | Number of Segment Loopback cells transmitted towards port. |
Port Rcv AIS cells | Number of AIS cells received in Ingress direction. |
Port Rcv FERF cells | Number of FERF cells received in Ingress direction. |
Port Rcv Segment Lpbk cells | Number of Segment Loopback cells received in Ingress direction. |
Port Rcv CRC Err OAM Cells | Number of OAM cells received in Ingress direction with CRC error. |
ingrRcvClpSetCells | Number of cells received from the port which had the CLP bit in the ATM cell header equal to 1. |
ingrXmtCells | Number of cells received from the port that were sent to the network. This count is taken after policing and ingress queueing. |
egrRcvCells | Number of cells received from the network in the egress direction. |
ingrRcvCellRate | Number of cells received per second from the port in the ingress direction. Maximum value is 5000 because clear E1 rate is 4830. |
ingrRcvUtilization | Percentage utilization of the port speed in the ingress direction. |
egrXmtCellRate | Number of cells transmitted to the port in the egress direction. |
egrXmtUtilization | Percentage utilization of the port speed in the egress direction. |
egrRcvCellRate | Number of cells received per second from the network in the egress receive direction. |
egrRcvUtilization | Percentage utilization of the port speed in the egress receive direction. |
totalIngrQfulldiscardCells | Total number of cells dropped on all the channels on this port because the ingress Q was full. Adds up all the IngressQfull discard per channel statistics for all the channels in the port. |
txFifoFullCnt | Count of the number of times the AUSM card tried to send a cell, but was unable to send because the Transmit FIFO was full. Note that this is NOT a count of the number of cells dropped. This statistics is per card statistics. This counter is duplicated in channel count group to help monitoring. |
totalIngrClpSetDiscardCells | Total number of cells with CLP=1 dropped on all the channels on this port because of either PCR Exceeded, SCR exceeded (with CLP tagging disabled), or CLP Hysteris. |
Rcv Hec Err Cnt | Number of cells with HEC error. |
Rcv Hec Err Sec Cnt | Number of seconds in which HEC error was there. |
Rcv Hec Err SE Sec Cnt | Number of Severely errored seconds. |
Clear Port Counters? | Resets all the counters. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Sep 29 13:11:23 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.