cc/td/doc/product/wanbu/9_3_05
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

VSI Commands

VSI Commands

Virtual Switch Interface (VSI) is a common control interface for MSSBU switches such as the BPX 8650 and the MGX 8850. Virtual Switch Interfaces (VSIs) allow a node to be controlled by multiple controllers, such as MPLS (Multiprotocol Label Switching, formerly called Tag Switching) and PNNI.

When a virtual switch interface (VSI) is activated on a port, trunk, or virtual trunk so that it can be used by a master controller, such as a SES PNNI or an MPLS controller, the resources of the virtual interface associated with the port, trunk or virtual trunk are made available to the VSI. These control planes can be external or internal to the switch. The Virtual Switch Interface provides a mechanism for networking applications to control the switch and use a partition of the switch resources.

VSI was implemented first on the BPX 8650 in Release 9.1, which uses VSI to perform Multiprotocol Label Switching. Release 9.1 allowed support for VSI on BXM cards and for partitioning BXM resources between Automatic Routing Management (formerly called AutoRoute) and a VSI-MPLS controller. Previous to this release, you could configure partition resources to be shared between Automatic Routing Management PVCs and one VSI control plane, but not both. You now can configure partition resources between Automatic Routing Management PVCs and two VSI controllers (LSC or PNNI).

The second implementation of VSI on the BPX provides the following extensioned functionality:


Caution You can use the VSI features (such as to configure a VSI-MPLS controller or a PNNI controller). However, you can still configure and use Automatic Routing Management PVCs. Use the cnfrsrc command to configure Automatic Routing Management PVCs.

For more overview information and specific information on how to configure a BPX 8650 switch, refer to the <CellCommandItalic>Cisco BPX Series Installation and Configuration. For information about configuring a 6400, 7200 or 7500 router for MPLS operation, refer to the MPLS Configuration Guide.

VSI Terms and Acronyms

These terms relate to Virtual Switching Interface and MPLS (Multiprotocol Label Switching):

ATM Edge LSR

  A label switching router that is connected to the ATM-LSR cloud through LC-ATM interfaces. The ATM edge LSR adds labels to unlabeled packets and strips labels from labeled packets.

ATM-LSR

  An ATM-LSR is a MPLS (Multiprotocol Label Switching) router in which packets are forwarded by switching cells rather than frames, and all packet interfaces are MPLS (Label) Controller-ATM interfaces.

A label switching router with a number of LC-ATM intefaces. The router forwards the cells from these interfaces using labels carried in the VPI and/or VCI field.

BCC

  The switch control card in the BPX is the Broadband Control Card, which has a 68040 processor.

BPX

  A high-end ATM switch called the Cisco Broadband Packet Exchange (BPX). The BPX is a carrier-quality switch, with trunk and CPU hot-standby redundancy.

BPX-LSR

  An ATM label switch router consisting of a label switch controller (series 6400, 7200 or 7500 router) and a label controlled switch (BPX switch).

BXM

  The Broadband Switch Module (BXM) cards are ATM port cards for the BPX switch that use the Monarch chipset. Various different port configurations are supported by the BXM card: 8¥DS3, 12¥DS3, 4¥OC-3, 8¥OC-3, 1¥OC-12 or 2¥OC-12. The Monarch architecture supports up to 64K bidirectional cross-connect legs per BXM card, although only 16K or 32K options are supported in the first release. The BXM has very flexible input and output queueing facilities, a Segmentation Assembly and Reassembly (SAR) capability, and a MIPS 4650 control processor.

Class of Service (CoS) Buffer

  A buffer or queue that serves connections with similar QoS requirements. Also called "QBin" (though a QBin is a platform-specific instance, such as a BXM card, of the more general Class of Service Buffer (CoSB).

Class of Service (CoS) Buffer Descriptor Template

  A component of a Service Class Template that contains Class of Service Buffer configurations indexed by CoSB number.
  A QBin is a platform-specific (BXM in this case) instance of the more general Class of Service Buffer (or CosB).

CLI

  There are two separate Command-Line Interfaces on the BPX-LSR: One on the BPX itself and one on the MPLS (Multiprotocol Label Switching) Controller. The Control Point integrate these into a single command line interface.

CommBus

  The CommBus is the BPX's internal messaging protocol.

CosB

  See Class of Service (CoS) Buffer.

Feeder

  A feeder is a small switch that acts as an extension shelf, typically with lower-bandwidth interfaces, for a larger switch. The larger switch is referred to as the Routing node with the feeder(s) it supports. Collectively, the feeder(s) and routing node form a type of supernode.

LC-ATM Interface

  A Label Controlled ATM interface is an MPLS (Multiprotocol Label Switching) interface where labels are carried in the VPI/VCI bits of ATM cells, and where VC (virtual circuit) connections are established under the control of MPLS (Multiprotocol Label Switching) control software.

LCN

  Each interface card in a BPX has a certain number of Logical Connection Numbers. A Logical Connection Number is used for each cross connect leg through the card in question. "LCN" is often roughly synonymous with "cross-connect leg." In VSI terminology, an LCN is an example of an Other End Reference.

Logical Interface

  Each physical interface and every virtual trunk endpoint on a platform is represented to the VSI controllers as a different logical interface with partitions, and other VSI configuration. Logical Interface numbers are 32-bit with a format which is, in general, known only to the platform.

LSR

  Label Switching router, which is an MPLS (Multiprotocol Label Switching) router.

PNNI

  Private Network-to-Network Interface controller software that runs on the SES hardware platform. The term PNNI controller and SES may be used interchangeably.

Port

  The VSI makes no distinction between trunk ports and endpoint ports. "Port" is synonymous with "Interface."

Routing Node

  In tiered networks terminology, a routing node is a larger switch to which one or more feeders is attached. Collectively, the feeder(s) and routing node form a type of supernode.

Service Class (aka Service Type)

  A concept for grouping connections that share a common set of traffic characteristics and QoS requirements. The terms service class and service type are sometimes used interchangeably.

Note   In this release, there are some major service categories, such as VbrRt, VbrNRt, CBR, Abr, and Ubr, and under these major service categories are service types such as VbrRt1, VbrRt2, VbrRt3, and VbrNRt1, VbrNrt2, and so on.

Service Class Database

  The collection of data items that support the service class template concept, and implemented on a per-VI basis on the BXM. These items include a B2_Body2copy of the specific Service Class Template selected for a VI, as well as additional data as required.

Service Class Template (SCT):

  A set of data structures that map VSI service types to sets of pre-configured VC and QBin parameters. Consists of two sub-components—a VC Descriptor Template and a Class of Service Buffer descriptor template.

VC

  ATM and Frame Relay traffic is carried in Virtual Channels that are set up between adjacent ATM or Frame Relay switches before data transmission occurs. An ATM link between switches may support up to 228 different VCs, although a small number of VCs is reserved for special purposes.

VCI

  Each VC within a specific Virtual Path on a link has a unique Virtual Channel Identifier, which is a 16-bit number.

VC Descriptor Template

  A component of a Service Class Template which contains platform-specific VC configurations that are indexed primarily by service type. Together with a Class of Service Buffer (CoSB) descriptor template, it defines a Service Class Template (SCT).

VP, VPC, VPI

  A Virtual Path is a bundle of 216 Virtual Connections with the same Virtual Path Identifier, that is, the first 12 bits of the VPCI. Most ATM switches can switch VPs using only a single cross-connect (instead of up to 216 ). An end-to-end sequence of VPs cross-connected at the intermediate swi5tches is a Virtual Path Connection.

VPCI

  Each VC on a link has a unique Virtual Path and Channel Identifier, which is a 28-bit number. The VPCI consists of a 12-bit VPI concatenated with a 16-bit VCI.

Virtual Trunks

  A Virtual Trunks is a Virtual Path Connection which appears to VSI masters as ordinary trunk (except that the trunk supports 64K VCs at most). In a VSI platform, a virtual trunk endpoint has its own logical interface.

VSI

  Virtual Switch Interface is a proposed common control interface to all Cisco MSSBU switches. It embodies both connection management and switch configuration discovery capabilities.

VSI 2

  Virtual Switch Interface, Protocol Version 2: this is revision 2 of a proposed common control interface to all MSSBU switches. It embodies both connection management and switch configuration discovery capabilities.

VSI Controller

  A controller, such as a PNNI SVC Controller, Portable AutoRoute or Label Switch Controller, which controls a switch using the VSI.

VSI Master

  A VSI master process implementing the master side of the VSI protocol in a VSI controller. Sometimes the whole VSI controller might be referred to as a "VSI Master", but this is not strictly correct.
1) A device that controls a VSI switch, for example, a VSI Label Switch Controller.
2) A process implementing the master side of the VSI protocol.

VSI Slave

  1) A switch (in the "Single Slave model") or a port card (in the "Multiple Slave Model") that implements the VSI.
2) A process implementing the slave side of the VSI protocol.

Summary of Commands

Table 16-1 shows the command name and starting page for the description of each VSI-related command.


Table 16-1: Commands for Setting up a Virtual Switch Interface (VSI) Controller
Mnemonic Description Page

addctrlr

Attach a controller to a node; for controllers that require Annex G capabilities in the controller interface. Add a PNNI VSI controller to a BPX node through an AAL5 interface shelf.

16-6

addshelf

Add a trunk between the hub node and interface shelf, VSI-MPLS (Multiprotocol Label Switching) controller, or and SES PNNI.

16-10

cnfqbin

Configure QBin parameters.

16-18

cnfrsrc

Configure resources, for example, for Automatic Routing Management PVCs and MPLS (Multiprotocol Label Switching) Controller (LSC).

16-25

cnfvsiif

Configure VSI Interface or a different template to an interface.

16-37

cnfvsipart

Configure VSI partition characteristics for VSI.

16-39

delctrlr

Delete a controller, such as a PNNI ESP (Extended Services Processor) 4.0 controller, from a BPX node.

16-40

delshelf

Delete a trunk between a hub node and access shelf.

16-43

dspchuse

Display a summary of channel distribution in a given slot.

16-46

dspctrlrs

Display the VSI controllers, such as an PNNI controller, on a BPX node.

16-50

dspqbin

Display QBin card.

16-45

dspqbint

Display QBin template.

16-50

dsprsrc

Display LSC (Label Switching Controller) resources.

16-50

dspsct

Display Service Class Template assigned to an interface.

16-50

dspvsiif

Display VSI Interface.

16-80

dspvsipartcnf

Display information about VSI ILMI functionality.

16-82

dspvsipartinfo

Display VSI resource status for the partition.

16-45

addctrlr

Adds VSI capabilities to a trunk interface to which a feeder of type AAL5 is attached. The addctrlr command is used only to connect a Private Network to Network Interface (PNNI) controller. PNNI controller software resides on the SES hardware.

The addctrlr command is the second step in the adding of a PNNI controller to a BPX node.

The first step is to run the command addshelf with shelf type set to P to add a AAL5 feeder. This ensures that Annex G protocol runs between the BPX and the SES.

Then run the addctrlr command to set up the VSI control channels from the PNNI SES controller to the VSI slave processes running on the BXM cards to ensure full VSI functionality for the PNNI controller. You execute the addctrlr command on an existing AAL5 interface shelf.

Also note that you can add a PNNI controller to a trunk interface only if the interface already has an active VSI partition corresponding to the partition that is controlled by the PNNI controller. Suppose a PNNI controller controlling the partition 1 were added to a trunk interface 12.1. Then it would be necessary that a VSI partition corresponding to partition 1 be active on the interface 12.1. Otherwise the addctrlr command would fail.

When you add VSI controller capabilities onto an AAL5 interface shelf (or feeder), the switch software prompts you for the specifics of the VSI controller:

There could be 12 BXM cards on the BPX node and the PNNI controller would control VSI partitions on those BXM cards that support VSI capability. Hence a separate VSI control channel must be set up from the PNNI control to each BXM card that supports VSI. Suppose you specify a VPI value of 0 and start VCI value of 40 for the VSI control channels. Then the control channel corresponding to any BXM card on slot 1 would use VPI, VCI values <0, 40>. The VSI control channels to other slots would use the VPI, VCI values of <0, 40+slot-1>, where "slot" corresponds to the slot number of the BXM card.


Caution For feeder trunk interfaces, the addctrlr command will fail if the AutoRoute connections terminating on the feeder interface use the same VPI VCI as those specified for the VSI control channels. You must delete the connections before proceeding if connections with VPI and VCI in the range exist in the range you specified.

The addition of a controller to a node will fail if there are not enough channels available to set up the control VCs in one or more of the BXM slaves.

Full Name

Add VSI capabilities to a AAL5 feeder interface

Syntax

addctrlr < slot.port> <controller id> <partition id> <control_vpi> <start_vci>


Table 16-2: Parameters—addctrlr
Parameter Description

<slot.port>

Slot and Port numbers corresponding to the feeder trunk.

<controller-id>

Controller ID corresponding to the PNNI controller, values 1 - 32.

<partition-id>

Partition ID of the VSI partition controlled by the PNNI controller.

<control_vpi>

Starting VPI of the VSI control channels used for communication between the VSI master residing on the SES and VSI slaves residing on the BXM cards. There can be a total of 12 such channels one for each slave residing on each BXM card.

For a trunk interface with NNI header type:
Valid values for this parameter are: 0-4095

For a trunk interface with UNI header type
Valid values for this parameter are: 0-255.

Default value: 0


Note   For a PNNI controller, we recommend against to modifying control_vpi and start_vci

<start_vci>

Starting VCI of the VSI control channels. This VCI value is assigned to the first VSI control channel (between the VSI master and the VSI slave residing on the BXM card in slot 1). The last VSI control channel corresponding to communication with the VSI slave on slot 14 will use the VCI value of (<start_vci>+14-1).

The valid values are: 33 - 65521.

Default value: 40


Note   For a PNNI controller, we recommend against to modifying control_vpi and start_vci

Related Commands

addshelf, delctrlr, dspctrlrs

Attributes
Privilege Jobs Log Node Lock

1

No

Yes

BPX

Yes

Example 1

addctrlr 10.4 3 2 0 40

Description

Add controller to port 4 on slot 10, partition ID of 2, and controller ID of 3.

System Response
night           TN   StrataCom     BPX 8600   9.2.00 Apr. 11 1998 14:31 GMT  
                                                                                
                    BPX Controllers Information 
 
 Trunk   Name       Type      Part Id   Ctrl ID   Ctrl IP       State        
 10.3    PNNI    VSI       1         1         192.0.0.0     Enabled
 11.1    VSI        VSI       2         2         192.0.0.0     Disabled
                                                                                
                                                                                
                                                                                
Warning partition already in use do you want to add redundant controller                                                                         
                                                                                
Last Command: addctrlr 10.4 3 2 0 40 
                                                                                
                                                                                
Next Command:      
 
Description

Adds a controller, such a PNNI controller, to a BPX interface shelf.

System Response
night           TN   StrataCom     BPX 8600   9.2.00 Apr. 11 1998 14:31 GMT  
                                                                                
                    BPX Controllers Information 
 
 Trunk   Name       Type      Part Id   Ctrl ID   Ctrl IP       State        
 10.3    PNNI    VSI       1         1         192.0.0.0     Enabled
 11.1    VSI        VSI       2         2         192.0.0.0     Disabled
                                                                                
                                                                                
                                                                                
Warning partition already in use do you want to add redundant controller                                                                         
                                                                                
Last Command: addctrlr 10.3 3 1 0 40 
                                                                                
                                                                                
Next Command:      
 
 
 
 

addshelf

Adds an ATM link between a hub node and an interface shelf such as an MGX 8220, an MGX 8850, or IGX shelf in a tiered network; or an ATM link between a BXM card on a BPX node and an MPLS (Multiprotocol Label Switching) controller such as a series 6400, 7200 or 7500 router; or an ATM link between a BXM card on a BPX node and an SES PNNI Controller. (An MPLS Controller or an SES PNNI Controller is considered an interface shelf from the BPX switch's perspective.) The routing hub can be either a BPX or an IGX.

The interface shelf can be one of the following:

The signaling protocol that applies to the trunk on an interface shelf is Annex G. For example, in this release, the IGX 8400 interface shelf with a BTM E1 interface communicates with the routing hub through the Annex G LMI using STI cell format. However, the MGX 8850 interface shelf, or feeder, communicates over a UXM/UXM-E interface with the routing hub over Annex G LMI using AAL5 format.


Note   Because tiered network capability is a paid option, personnel in the Cisco Technical Assistance Center (TAC) must telnet to the unit and configure it as an interface shelf before you can execute addshelf.

Each IGX/AF, MGX 8220, or MGX 8850 shelf has one trunk that connects to the BPX or IGX node serving as an access hub. A BPX routing hub can support up to 16 T3 trunks to the interface shelves, which can be IGX/AF, MGX 8220, or MGX 8850 interface shelves. An IGX hub can support up to four trunks to the interface shelves, which can be IGX/AF shelves only.

An IGX 8400 interface shelf can connect to an IGX 8400 routing hub over a BTM E1 interface using STI cell format. In Release 9.1, an IGX 8400 interface shelf can connect to an MGX 8800 over a UXM/UXM-E interface using ATM cell format.

Before it can carry traffic, you must "up" trunk on an interface shelf (using uptrk) on both the interface shelf and the hub node and "add" it to the network (using addshelf). Also, a trunk must be free of major alarms before you can add it with the addshelf command.

In this release, the new parameters "Control VPI" and "Control VCI start" have been added.

In this release, addshelf will prevent adding a feeder to a trunk if a VSI ILMI session is active on a VSI partition on the trunk interface.

Adding a VSI Controller

The maximum number of controllers that can be attached to a given node is limited by the maximum number of feeders (16) that can be attached to a BPX hub. Therefore the total number of feeders and controllers cannot exceed 16.

You add a VSI controller, such as an MPLS (Multiprotocol Label Switching) Controller, to a switch with the addshelf command using the vsi option. The vsi option of the addshelf command is used to identify VSI controllers and tell them apart from interface shelves (feeders). The VSI controllers are allocated a partition of the switch resources. VSI controllers manage their partition through the VSI interface. The controllers run the VSI master. The VSI master entity interacts with the VSI slave running on the BXMs through the VSI interface, to set up VSI connections using the resources in the partition assigned to the controller. Two controllers that are intended to be used in a redundant configuration must specify the same partition when added to the node through the addshelf command.

When a controller is added to the node switch software will set up the infrastructure so that the controllers can communicate with the slaves in the node. The VSI entities decide how and when to use these communication channels.

In addition, the controllers require a communication channel between them. This channel could be in-band or out-of-band. When a controller is added to the switch, switch software will send controller information to the slaves. This information will be advertised to all the controllers in the partition. The controllers may decide to use this information to set up an intermaster channel. Alternatively the controllers may use an out-of-band channel to communicate.

The maximum number of controllers that can be attached to a given node is limited by the maximum number of interface shelves (feeders) that can be attached to a BPX hub. This number in Release 9.2 is 16. Therefore the total number of feeders and controllers cannot exceed 16.

To add a controller to the node, use the addshelf command. A redundant controller is added in the normal way, except that it specifies a partition that may be already in use by another controller. In this release the addshelf command allows for up to two controllers to manage the same partition.

One of the parameters that must be specified with the addshelf command when a VSI controller is added to the switch is the controller id. This is a number between 1 and 32 that uniquely identifies the controller. Two different controllers must always have different controller IDs.

The management of resources on the VSI slaves requires that each slave in the node has a communication control VC to each of the controllers attached to the node. When a controller is added to the BCC via the addshelf command, the BCC sets up the set of master-slave connections between the new controller port and each of the active slaves in the switch. The master slave connections are specified via the <Control VPI> and <Control Start VCI> parameters. The default for these parameters is 0/0.

Feature Mismatching to Verify VSI Support

The cnfrsrc and addshelf commands, in addition to other configuration commands, will perform mismatch verification on the BXM and UXM cards. For example, the cnfrsrc and addshelf commands will verify whether the cards both have VSI 2.0 support configured.

The Feature Mismatching capability will not mismatch cards unless the actual feature has been enabled on the card. This allows for a graceful card migration from an older release.

Full Name

Add an interface shelf (feeder) or a controller to a routing node or hub.

Syntax

Interface shelf:

addshelf <slot.port> <shelf-type> <vpi> <vci>

MPLS (Multiprotocol Label Switching) controller:

addshelf <trunk slot.port> v <ctrlr id> <part id> <control vpi> <control vci start> <redundant ctrlr warning>


Note   If you manage a tiered network through the command line interface, you can manage only Frame Relay interworking connections (ATFR) across the network. Three-segment connections for carrying serial data or voice between IGX/AFs is allowed, but you must manage them through WAN Manager.

Related Commands

addctrlr, delshelf, dspnode, dsptrks

Attributes
Privilege Jobs Log Node Lock

1-4

Yes

Yes

BPX switch with IGX interface shelf
IGX switch with IGX shelves

BPX switch with the MGX 8220 shelf

BPX with the MGX 8850 shelf

BPX switch for MPLS (Multiprotocol Label Switching) controller (LSC)

Yes

Example 1

Interface shelf: addshelf 11.1 a 21 200

MPLS (Multiprotocol Label Switching) controller: addshelf 4.1 vsi 1 1

Description

Interface shelf:

Add trunk 11.1 as an MGX 8220 interface shelf. After you add the shelf, the screen displays a confirmation message and the name of the shelf.

MPLS (Multiprotocol Label Switching) controller:

Add trunk 4.1 as a VSI-MPLS (Multiprotocol Label Switching) Controller interface shelf. After you add the LSC, the screen displays a confirmation message and the name of the shelf.

Description for Interface Shelves

An interface shelf can be one of the following:


Table 16-3: addshelf—Interface Shelf Parameters
Parameter Description

slot.port (trunk)

slot.port

Specifies the slot and port number of the trunk.

shelf-type

I or A or X

On a BPX node, shelf type specifies the type of interface shelf when you execute addshelf. The choices are I for /AF or IGX/AF, A for the MGX 8220 and PNNI SES, V for VSI, or X for the MGX 8800. On an IGX hub, only the IGX/AF is possible, so shelf type does not appear.

vpi vci

Specifies the VPI and VCI (Annex G VPI and VCI used). For the MGX 8220 only, the valid range for VPI is 5-14 and for VCI is 16-271. For an IGX/AF interface shelf, the valid range for both VPI and VCI is 1-255.

On an IGX 8400 node, when using an MGX 8800 interface shelf, the following VPI/VCI limits apply:

  • Use the VPI/VCI combination of 3/31 for the LMI signaling channel. When adding an MGX 8800 as an interface shelf, do not use 3/31 for anything else but the LMI signaling channel.

  • For VCC addressing, the VPI range is 1-255 and the VCI range is 1-65535.

  • For VPC addressing, the interface type is significant: UNI or NNI may be supported. When the interface type is UNI, the available VPI range is 1-255 and VCI range is 1-65535. When the interface type is NNI the available VPI range is 1-4095 and VCI range is 1-65535.

control_vpi

Choose the value for <control_VPI> such that:

if <control_VPI> = 0, <control_VCI_start> can be set to a value > 40.

If any VSI partition exists on the interface, then control_VPI < start_VPI or control_VPI > end_VPI for all partitions on that interface. An error message appears if the control VPI falls into the VPI range belonging to a VSI partition.

No AutoRoute connection exists on (VPI.start_VCI to VPI.start_VCI+14). If any AutoRoute connection exists on these VPI/VCI values, you are not allowed to use these VPI/VCI values.

This VPI is reserved for control VCs.

Default = 0

control_vci_start

Default = 40

The (VPI.VCI) of the 15 control VCs is:
(control_VPI.control_VCI_start) to (control_VPI.control_VCI_start+14).

The control VC used for slot n (1<= n<=15) is:
(control_VPI.control_VCI_start + n -1).

Example for Interface Shelves

Add an MGX 8220 at trunk 11.1 After you add the shelf, the screen displays a confirmation message and the name of the shelf. Add the MGX 8220 (may be referred to on screen as AXIS) as follows:

addshelf 11.1 a

The sample display shows a partially executed command prompting you for the interface shelf type:

System Response
nmsbpx23       TN    SuperUser       BPX 8620    9.2   Apr. 4 1998 13:28 PST
 
                        BPX Interface Shelf Information
 
Trunk    Name      Type      Alarm
 1.3     AXIS240   AXIS      OK
 11.2    A242      AXIS      OK
 
 
 
 
 
 
This Command: addshelf 11.1 
 
Enter Interface Shelf Type:  I (IGX/AF), A (AXIS), P (APS), V (VSI), X (AAL5)  
 
Next Command:
 
Example for Adding an MGX 8850 AAL5 (ATM Adaptive Layer/5) Interface Shelf

Add an MGX 8850 at trunk 4.8. After you add the MGX 8800 shelf, the screen displays a confirmation message and the name of the shelf. Add the MGX 8850 (may be referred to on screen as AAL5) as follows:

addshelf 4.8 x

The sample display shows that an MGX 8850 was added on trunk 4.8 as an AAL5 (ATM Adaptive Layer/5 type of interface shelf. (Adding an MGX 8850 interface shelf is similar to adding an MPLS Controller interface shelf.)

System Response
pswbpx3       TN    SuperUser       BPX 8600    9.1   June 6 1998 13:28 PST
 
                        BPX Interface Shelf Information
 
Trunk    Name      Type      Part Id    Ctrl Id    Alarm
 4.8     SIMFDR0   AAL5         -           -      OK
 
 
 
 
 
This Command: addshelf 4.8 x 
 
Enter Interface Shelf Type:  I (IGX/AF), A (AXIS), P (APS), V (VSI), X (AAL5)  
 
Next Command:
 
Description for MPLS

For MPLS, before it can carry traffic, you need to up the link to a MPLS controller (by using uptrk) at the BPX node. You can then add the link to the network (by using addshelf). Also, the link must be free of major alarms before you can add it with the addshelf command.


Note   Once you up a port on the BXM in either trunk or port mode by using either the uptrk or upport commands, respectively, you can only up the ports in the same mode.


Table 16-4: addshelf—MPLS Parameters
Parameter Description

slot.port

Specifies the BXM slot and port number of the trunk. You can configure the port for either trunk (network) or port (service) mode.

device-type

VSI, which is "virtual switch interface, specifies a virtual interface to an MPLS controller (TSR) such as a Cisco 6400, 7200 or 7500 series router.

control ID

Control IDs must be in the range of 1 to 32, and you must set these identically on the LSC and in the addshelf command. A control ID of "1" is the default used by the MPLS (Multiprotocol Label Switching) controller (LSC).

control VPI

Starting VPI of the VSI control channels used for communication between the VSI master residing on the SES and VSI slaves residing on the BXM cards. There can be a total of 12 such channels one for each slave residing on each BXM card.

For a trunk interface with NNI header type:

Valid values for this parameter are: 0-4095

For a trunk interface with UNI header type

Valid values for this parameter are: 0-255.

Default value: 0

start VCI

Starting VCI of the VSI control channels. This vci value is assigned to the first VSI control channel (between the VSI master and the VSI slave residing on the BXM card in slot 1). The last VSI control channel corresponding to communication with the VSI slave on slot 14 will use the vci value of

(<start_vci>+14-1).

The valid values are: 33 - 65521.

Default value: 40

Example for MPLS

Add a MPLS controller link to a BPX node by entering the addshelf command at the desired BXM port as follows:

addshelf 4.1 vsi 1 1

System Response
nmsbpx23       TN    SuperUser       BPX 15    9.1   Apr. 4 1998 13:28 PST
 
                        BPX Interface Shelf Information
 
Trunk    Name      Type      Alarm
 5.1     j6c       AXIS      MIN
 5.3     j5c       /AF    MIN
 4.1     VSI       VSI       OK
 
 
 
 
 
 
This Command: addshelf 4.1 v 1 1 
 
Next Command:
 
Example for VSI Controller

Add a VSI controller link to a BPX node by entering the addshelf command at the desired BXM port as follows:

addshelf 13.2

System Response
 
sw237          TN    StrataCom       BPX 8620  9.2.L3    May  10 1999 14:48 PST 
 
TRK       Type     Current Line Alarm Status               Other End
 4.1     [T3       Clear - OK                              VSI(VSI)
10.1      OC-3      Clear - OK                              VSI(VSI)
10.5      OC-3      Clear - OK                              VSI(VSI)
13.1.1    OC-3      Clear - OK                              -
13.2      OC-3      Clear - OK                              -
 
 
 
 
 
 
 
                                                                                
This Command: addshelf 13.2  
 
 

addyred

Enables card redundancy for IGX and BPX cards. Use the addyred command to specify the slots of the primary and secondary (standby) cards that form the redundant pair.

You must use the addyred command to configure a VSI slave redundant card. When a standby slave card is first started (either by having been inserted into the slot, or if the user issues the addyred command from the CLI console), the active slave VSI forward all VSI messages it had received from the Master VSI controller card to the standby slave VSI controller card.

Redundant card sets must have the following characteristics:

In both the single and multiport card sets, if the secondary card set becomes active, the primary card set serves as its backup (assuming the primary card set is complete and not failed). You cannot use the addyred command if the primary and secondary slots are empty. If cards reside in the primary and secondary slots, the system checks for card compatibility. Two types of incompatibility can occur: back card and jumper or cable inconsistencies. (On SDI, FRI, and FTI cards, jumpers determine whether a port is configured as DCE or DTE. On LDI cards, either a DCE or DTE adapter cable connects to the LDI port. For descriptions of the jumper positions and cabling, see the Cisco IGX 8400 Series Installation and Configuration manual.)

Note that the addyred command prevents invalid configurations when you try to configure the SONET APS feature. When SONET Automatic Protection Switching (APS) is configured, you will not be able to use the addyred or delyred commands on a card configured for APS 1:1 architecture. That is, you will not be able to execute the addyred command, then configure the APS 1:1 architecture. Similarly, you will not be able to configure APS 1:1, then execute the addyred command. You will be blocked from executing these commands at the command line interface.

If incompatibilities exist, the message "Y-Cable Conflict" appears on the screen. Specific conflicts are listed in reverse video in the dspyred display. See the dspyred description for more information.

To ensure that only cards with the Idle Code Suppression feature enabled on them are allowed to be a Y-redundancy pair, addyred blocks cards that have different idle code suppression capability.

Full Name

Add Y-cable redundancy.

Syntax

addyred <primary slot> <secondary slot>

Related Commands

delyred, dspyred, prtyred

Attributes
Privilege Jobs Log Node Lock

1-4

No

Yes

IGX, BPX

Yes

Example 1

addyred 25 26

Description

Add Y-cable redundancy to the SDP/SDI card sets in slots 25 and 26.

System Response
beta           TRM   YourID:1        IGX 8420    9.2    Aug. 15 1998 14:27 MST 
                                                                                
     Slot Other Front  Back   Channel Configuration                             
Slot Type Slot  Card   Card     1    2    3    4    5    6    7    8            
2    Pri    3   BXM    LM-BXM                              
3    Sec    2   BXM    LM-BXM                              
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
 
                                                                                
                                                                                
Last Command: addcdred 2 3                                                      
                                                                                
                                                                                
Next Command: 
 


Table 16-5: baddyred-Parameters
Parameter Description

primary slot

Specifies the slot number of the primary card set.

secondary slot

Specifies the slot number of the secondary card set.

cnfqbin

Use the cnfqbin command to configure the Qbin (Class of Service Buffers parameters on a selected BXM port or trunk. The cnfqbin command prompts you to configure the Qbin from the template assigned to a logical interface.

This command now lets you accept the interface template as the values, as an option. For example, you can type in Yes when prompted whether the interface service class template (SCT) should be used, and the command will use the card Qbin values from the Qbin templates. You will not be allowed to enter values for any Qbin parameter in this case. You can, however, enter desired values if the template option has not been chosen.

When a VSI interface is activated, the default template gets assigned to an interface. The corresponding Qbin template gets copied into the card Qbin data structure for that interface. When you want to change this, by giving new values using the cnfqbin command, the Qbin is now user configured as opposed to template configured. This information is displayed on the dspqbin screen. It indicates whether the values in the Qbin are from the template assigned to the interface OR the values have been changed to user-defined values. The cnfqbin command will prompt you whether template should be used for Qbin parameters. In this release, the dspqbin command now displays all the fields of a Qbin template.

The cnfqbin command was introduced in Rel 9.1 to configure any Qbin on the BXM cards. In this release, it has been extended to support virtual trunks. When the virtual trunk is dedicated to the controller, you can only configure Qbin 10-15.

VC connections are grouped into large buffers called Qbins. (Per-VC queues can be specified on a connection-by-connection basis also). In this release, all VSI connections use Qbin 10 on each interface.

You configure Multiprotocol Label Switching (formerly Tag Switching) for VSIs on a BXM card is configured using the cnfrsrc and cnfqbin commands. Qbin 10 is assigned to label switching.

Use the cnfqbin command is used to adjust the threshold for the traffic arriving in Qbin 10 of a given VSI interface as away of fine tuning traffic delay.

If you use the cnfqbin command to set an existing Qbin to disabled, the egress of the connection traffic to the network is disabled. Re-enabling the Qbin restores the egress traffic.


Note   Cell Delay Variation (CDV) is based on the Qbin depths and the transmission speed of the virtual switch interface. The default Qbin depths are specified in the service class templates (SCTs). You can configure the Qbin depths by using the cnfqbin command.
Cell Tolerance Delay (CTD), which is the fixed delay, is based on a fixed value, and is not configurable.

The cnfqbin command prompts you whether "template" should be used for Qbin parameters.

Full Name

Configure Qbin

Syntax

cnfqbin <slot number>.<port number>.<vtrk>

Related Commands

dspqbin

Attributes
Privilege Jobs Log Node Lock

1-6

Yes

No

BPX

No

Example 1

cnfqbin 13.1

Description

Create a Qbin configuration on the OC-3 trunk on port 1 of slot 13 on the BPX to support MPLS.

System Response
sw57           TN    SuperUser       BPX 8600    9.2    Mar. 10 1997 10:41 GMT 
 
Port/Trunk:       13.1    [ACTIVE ]
Qbin Id :
Enable Qbin (Y/N) :
Minimum Bandwidth : 	
Qbin Discard threshold:
Low CLP threshold: 	[80] %
High CLP threshold: 	[80] %
EFCI threshold:	[30]%
 
 
 
                                                                                
Last Command: cnfqbin 13.1
 
 
Example 2

cnfqbin 4.1 10

Description

Configure the Qbin 10 for port 4.1; also configure ports 4.2 and 4.3, and enter port 4.2 and 4.3 where applicable.

If the Qbin is not configured, configure the queues on the ports using the cnfqbin command:

  cnfqbin 4.1 10
  enable/disable: e

For all other parameters, accept the (default).

The previous parameters can also be set for Qbin 10 as follows:

  cnfqbin 4.1 10 e 0 65536 95 100 40
System Response
Sample Display:
n4             TN    SuperUser       BPX 15    9.2      Apr. 4 1998  16:41 PST 
Qbin Database 4.1 on BXM qbin 10
Qbin State:                   Enabled
Minimum Bandwidth:             0
Qbin Discard threshold:       65536
Low CLP/EPD threshold:        95%
High CLP/EPD threshold:       100%
EFCI threshold:               40%
                                                                                
This Command: cnfqbin 4.1 10  
'E' to Enable, 'D' to Disable [E]: 
 
Next Command:
 
System Response
n4             TN    SuperUser       BPX 8620    9.2      Apr. 4 1998  16:41 PST 
 
Qbin Database 4.1 on BXM qbin 10
 
Qbin State:                   Enabled
Minimum Bandwidth:             0
Qbin Discard threshold:       65536
Low CLP/EPD threshold:        95%
High CLP/EPD threshold:       100%
EFCI threshold:               40%
                                                                                
                                                                                
Last Command: cnfqbin 4.1 10 e 0 65536 95 100 40
 
Next Command: 
 


Table 16-6: cnfqbin—Parameters
Parameter Description

slot.port

Specifies the BXM card slot and port number.

Qbin ID

Specifies the ID number of the Qbin available for use by the LSC (MPLS Controller) for VSI. The range is 0 to 255.; 0 is the default. Always use 10 in 9.1.

Enable Qbin

Answer yes or no to enable your Qbin configuration.

Minimum Bandwidth

Specifies the minimum bandwidth in cells per second available for the Qbin. The range is 0 to 352207; 0 is the default.

Qbin Discard Threshold

Specifies the threshold in percentage for Qbin discard. The range is 0 to 100.

CLP Low Threshold

Specifies the threshold in percentage for CLP low. The range is 0 to 100; 80% is the default.

CLP High Threshold

Specifies the threshold in percentage for CLP high. The range is 0 to 100; 80% is the default.

EFCI threshold

Specifies the threshold in percentage for EFCI. The range is 0 to 100; 30% is the default.

Template

Specifies that the interface service class template should be used to configure the Qbin parameters. Thus the cnfqbin command will use the card's Qbin values from the Qbin template. If you do not chose the template option, you can enter your own desired values for the Qbin parameters.

Qbin Dependencies

The available Qbin parameters are shown in Table 16-7. Notice that the Qbins available for VSI are restricted to Qbins 10-15 for that interface. All 32 possible virtual interfaces are provided with 16 For Qbin default settings, see Table 16-7. Qbins. Refer to Table 16-8 for a listing of cnfqbin parameters with possible values and ranges.

.
Table 16-7: Qbin Default Settings
Qbin Max Qbin Threshold (usec) CLP High CLP Low/EPD EFCI Discard Selection
LABEL
Template 1

10 (Null, Default, Signalling, Tag0,4)

300,000

100%

95%

100%

EPD

11 (Tag1,5)

300,000

100%

95%

100%

EPD

12 (Tag2,6)

300,000

100%

95%

100%

EPD

13 (Tag3,7)

300,000

100%

95%

100%

EPD

14 (Tag Abr)

300,000

100%

95%

6%

EPD

15 (Tag unused)

300,000

100%

95%

100%

EPD

PNNI
Templates 2 (with policing) and 3

10 (Null, Default, CBR)

4200

80%

60%

100%

CLP

11 (VbrRt)

53000

80%

60%

100%

EPD

12 (VbrNrt)

53000

80%

60%

100%

EPD

13 (Ubr)

105000

80%

60%

100%

EPD

14 (Abr)

105000

80%

60%

20%

EPD

15 (Unused)

105000

80%

60%

100%

EPD

Full Support for ATMF and reduced support for Tag CoS without Tag-Abr
Templates 4 (with policing) and 5

10 (Tag 0,4,1,5, Default, UBR, Tag-Abr*)

300,000

100%

95%

100%

EPD

11 (VbrRt)

53000

80%

60%

100%

EPD

12 (VbrNrt)

53000

80%

60%

100%

EPD

13 (Tag 2,6,3,7)

300,000

100%

95%

100%

EPD

14 (Abr)

105000

80%

60%

20%

EPD

15 (Cbr)

4200

80%

60%

100%

CLP

Full Support for Tag ABR and ATMF without Tag CoS Templates 6 (with policing) and 7

10 (Tag 0,4,1,5,2,6,3,7 Default, UBR)

300,000

100%

95%

100%

EPD

11 (VbrRt)

53000

80%

60%

100%

EPD

12 (VbrNrt)

53000

80%

60%

100%

EPD

13 (Tag-Abr)

300,000

100%

95%

6%

EPD

14 (Abr)

105000

80%

60%

20%

EPD

15 (Cbr)

4200

80%

60%

100%

CLP

Full Support for Tag CoS and reduced support for ATMF Templates 8 (with policing) and 9

10 (Cbr, Vbr-rt)

4200

80%

60%

100%

CLP

11 (Vbr-nrt, Abr)

53000

80%

60%

20%

EPD

12 (Ubr, Tag 0,4)

300,000

100%

95%

100%

EPD

13 (Tag 1, 5, Tag-Abr)

300,000

100%

95%

6%

EPD

14 (Tag 2,6)

300,000

100%

95%

100%

EPD

15 (Tag 3, 7)

300,000

100%

95%

100%

EPD


Table 16-8: cnfqbin—Parameters
Template Object Name Template Units Template Range/Values

Qbin Number

enumeration

0 -15 (10-15 valid for VSI)

Max Qbin Threshold

u sec

1-2000000

Qbin CLP High Threshold

% of max Qbin threshold

0 - 100

Qbin CLP Low Threshold

% of max Qbin threshold

0 - 100

EFCI Threshold

% of max Qbin threshold

0 - 100

Discard Selection

enumeration

1 - CLP Hystersis

2 - Frame Discard

Weighted Fair Queueing

enable/disable

0: Disable

1: Enable

cnfrsrc

Use the cnfrsrc command to partition resources for Automatic Routing Management PVCs, VSI-MPLS (Multiprotocol Label Switching), or VSI-PNNI (Private Network to Network Interface).

You can configure a port, trunk, or virtual trunk to support VSI. You can configure a virtual trunk to be dedicated to VSI or to Automatic Routing Management. You cannot configure a virtual trunk for both VSI and Automatic Routing Management.

The switch software:

Configurable resources (using cnfrsrc) are:

Resource Partitioning

The VSIs need to partition the resources between competing controllers: Automatic Routing Management, MPLS (Multiprotocol Label Switching), and PNNI for example. You can have different types of controllers splitting up a partition's assets. For example, Automatic Routing Management, and MPLS, or Automatic Routing Management and PNNI (SVCs), but not PNNI and MPLS.

The PVC VIP ranges are added to facilitate migration of PVCs to PNNI SPVCs. PVC VIP ranges are allowed to overlap with the VSI VPI range if the VSI partition is for PNNI. Overlapping of PVC VPI range with MPLS VPI range is not supported. When overlapping VIP range, users will be asked if the VSI partition is for MPLS. If it is, the command will fail.

This release supports one or two partitions only. In this release, two controllers of a single type are supported. The user interface will block the activation of partitions with ID higher than 1 if the card does not support multiple partitions.

If none of the PVC VPI range is defined, when enabling a partition, if [start_VSI_VPI, end_VSI_VPI] of the partition contains any "reserved" VPI, an error message is displayed and you are prompted for different values for start_VPI, end_VPI. Thus, if VPI 10 is used for control VCs on an interface, then you cannot include VPI 10 in any VSI partition by using the cnfrsrc command. An error message would be displayed.

If PVC VIP ranges are defined such that they covers all PVCs including VSI control VCs, users are allowed to enable a VSI partition with VPI range overlapping with the PVC VPI ranges. Thus, if VPI 10 is used for VSI control VC on an interface, then you can include VPI 10 in a VSI partition if it is also included in the PVC VPI range for that interface. A warning message of VPI overlapping will be displayed.

The resources that you need to configure for a partition are shown in Table 16-9 for a partition designated ifci, which stands for interface controller 1, in this example. The three parameters that need to be distributed are: 1) number of logical connections (lcns); 2) bandwidth (bw); and 3) virtual path identifiers (vpi).


Table 16-9: ifci—Parameters (Virtual Switch Interface)
ifci parameters Min Max

lcns

min_lcnsi

max_lcnsi

bw

min_bwi

max_bwi

vpi

min_vpi

max_vpi

The controller is supplied with a logical LCN connection number, that is slot, port, and so on. Information is converted to a logical connection number (lcn).

Some ranges of values available for a partition are listed in Table 16-10:


Table 16-10: Partition Criteria
Partition Range

trunks

1-4095 VPI range

ports

0-4095 (NNI), 0-255 (UNI)

virtual trunk

Only one VPI available per virtual trunk since a virtual trunk is currently delineated by a specific VP

virtual trunk

Each virtual trunk can either be Automatic Routing Management or VSI, not both

When you add a trunk, the entire bandwidth is allocated to Automatic Routing Management (formerly known as AutoRouting). To change the allocation to provide resources for a VSI, use the cnfrsrc command on the BPX switch. A view of the resource partitioning available is shown in Figure 16-1.


Figure 16-1: Graphical View of Resource Partitioning, Automatic Routing Management and VSI


Partition Information Sent to Cisco WAN Manager

When the partition information is configured for the first time or any parameters are changed, Cisco WAN Manager will be updated through a robust message.

Partitioning

On each interface (port or trunk) on the BXM cards used for label switching, two sets of resources must be divided up between traditional PVC connections and label switching connections. The traditional PVC connections are configured directly on the BPX platform, and label switching connections are set up by the TSC using the VSI. The following resources are partitioned on each interface:

As with all ATM switches, the BPX switch supports up to a specified number of connections. On the BPX switch, the number of connections supported depends on the number of port/trunk cards installed. On each interface, space for connections is divided up between traditional BPX switch permanent virtual circuit (PVC) connections, and Label Switching VCs (LVCs), or PNNI SPVCs/SVCs.

cnfrsrc Parameters, Possible Values, and Descriptions

See Table 16-11 for a listing of cnfrsrc parameters, ranges and values, and descriptions. These parameters appear on the cnfrsrc screen.


Table 16-11: cnfrsrc Parameters, Ranges/Values, and Descriptions
Object Name Range/Values Default Description

VSI Start LCN

0... 64K-1

NA

Start LCN for the whole VSI partition.

Each VSI sub-partition (specific partition-id) will be given lcns from this partition. subject to the min/max ranges for that partition-id specified in object 3.

The Start LCN once set will not be permitted to change if there are any active/configured VSI partitions.

VSI End LCN

0...64 K-1

NA

End LCN for the whole VSI partition.

If End LCN cannot be satisfied due to existing VSI connections or other constraints in this range then firmware will reject this request with a get response (same message tag) with this Object indicating the possible new End LCN that firmware can accommodate.

VSI partition

1...3

0

identifies the partition

Partition state

0 = Disable Partition

1 = Enable Partition

NA

For Partition state = 1, Objects (8, 9, A, B, C, D, E, F) are mandatory

Min LCNs

0...card

NA

Min lcns (conns) guaranteed for this partition

Max LCNs

0...Card limit

NA

Maximum LCNs permitted on this partition

Start VPI

0 ... 4095

NA

Partition Start VPI

End VPI

0 ... 4095

NA

Partition End VPI

Min Bw

0...port bandwidth

NA

Minimum Partition bandwidth

Max Bw

0...port bandwidth

NA

Maximum Partition bandwidth

Feature Mismatching to Verify VSI Support

In this release, the cnfrsrc and addshelf commands, in addition to other configuration commands, performs mismatch verification on the BXM and UXM cards. For example, the cnfrsrc and addshelf commands will verify whether the cards both have VSI 2.0 support configured.

The Feature Mismatching capability will not mismatch cards unless the actual feature has been enabled on the card. This allows for a graceful card migration from an older release.

Full Name

Configure resources

Syntax

cnfrsrc <slot.port.vtrk>

or

cnfrsrc <slot>.<port>.<vtrk> <maxpvclcns><maxpvcbw><configurepvcvpirange> <pvcstartvpi><pvcendvpi><pvcstartvpi><pvcendvpi><pvcstartvpi><pvcendvpi><pvcstartvpi><pvcendvpi><configurevsipart><partition> <e/d> <minvsilcns> <maxvsilcns> <vsistartvpi> <vsiendvpi><vsiminbw> <vsimaxbw>

Related Commands

dsprsrc

Attributes
Privilege Jobs Log Node Lock

1-6

No

No

BPX

No

Example 1

cnfrsrc 9.1 256 96000 N N

Description

Configure resource for port 9.1.

System Response
	
sw215          TN    Cisco           BPX 8620  9.3.f9    May  31 2000 15:29 GMT 
 
Port : 9.1
                                      Full Port Bandwidth: 96000
Maximum PVC LCNS:             256     Maximum PVC Bandwidth: 96000
                                      (CAC Reserve: 0)
 
PVC VPI RANGE [1]:   -1    /-1        PVC VPI RANGE [2]: -1    /-1
PVC VPI RANGE [3]:   -1    /-1        PVC VPI RANGE [4]: -1    /-1
 
          Partition :  1                 2                 3
    Partition State :  Disabled          Disabled          Disabled
  VSI LCNS (min/max):  0      /0         0      /0         0      /0
 VSI VPI (start/end):  0     /0          0     /0          0     /0
    VSI BW (min/max):  0      /0         0      /0         0      /0
     VSI ILMI Config:  CLR               CLR               CLR
 
                                                                                
Last Command: cnfrsrc 9.1 256 96000 N N
 
	Next Command:
 
Example 2

cnfrsrc 12.1 800 348207 y 1 E 100 3000 10 300 2000 96000

System Response
sonofsam       TN    Cisco           BPX 8620  9.3.0k    June 20 2000 08:51 GMT
 
Trunk : 12.1
                                      Full Port Bandwidth: 353208
Maximum PVC LCNS:             800     Maximum PVC Bandwidth: 252207
                                      (Statistical Reserve: 5000)
 
PVC VPI RANGE [1]:   -1    /-1        PVC VPI RANGE [2]: -1    /-1
PVC VPI RANGE [3]:   -1    /-1        PVC VPI RANGE [4]: -1    /-1
 
          Partition :  1                 2                 3
    Partition State :  Enabled           Disabled          Disabled
  VSI LCNS (min/max):  100    /3000      0      /0         0      /0
 VSI VPI (start/end):  10    /300        0     /0          0     /0
    VSI BW (min/max):  2000   /96000     0      /0         0      /0
     VSI ILMI Config:  SET               CLR               CLR
 
 
Last Command: cnfrsrc 12.1 800 348207 y 1 E 100 3000 10 300 2000 96000
Description

Partition resource on trunk 12.1 on the BPX to support VSI service such as MPLS or PNNI.


Note   By default the LSC will use either a starting VSI VPI of 1 or 2 for label switching, whichever is available. If both are available, a starting VSI VPI of 1 is used. The VPI range should be 2-3 on a BPX VSI connected to a 6400, 7200 or 7500 AIP. If VPI 2 is not to be used, the label switching VPI interface configuration command can be used on the TSC to override the defaults


Note   The VSI range for label switching on the BPX switch is configured as a VSI partition, usually VSI partition number 1. VSI VPI 1 is reserved for Automatic Routing Management, so the VSI partition for label switching should start at VPI 2. Two VPIs are sufficient for the current release, although it may be advisable to reserve a larger range of VPIs for later expansion, for example, VPIs 2-15.

Table 16-12 lists the cnfrsrc parameters, focusing more on configuring resources for VSI partitions (an MPLS controller, for example). For more information on configuring resources for Automatic Routing Management PVCs, refer to the cnfrsrc command.

Example 3

cnfrsrc 9.6.1 256 3096

Description

Configure virtual port 6.1 on the BXM card in slot 9 with a maximum of 256 PVC LCNS and a bandwidth of 3096.

System Response
sw215          TN    Cisco           BPX 8620  9.3.f9    May  31 2000 15:28 GMT 
 
Port : 9.6.1
                                      Full Port Bandwidth: 3096
Maximum PVC LCNS:             256     Maximum PVC Bandwidth: 3096
                                      (CAC Reserve: 0)
 
PVC VPI RANGE [1]:   -1    /-1        PVC VPI RANGE [2]: -1    /-1
PVC VPI RANGE [3]:   -1    /-1        PVC VPI RANGE [4]: -1    /-1
 
          Partition :  1                 2                 3
    Partition State :  Disabled          Disabled          Disabled
  VSI LCNS (min/max):  0      /0         0      /0         0      /0
 VSI VPI (start/end):  0     /0          0     /0          0     /0
    VSI BW (min/max):  0      /0         0      /0         0      /0
     VSI ILMI Config:  CLR               CLR               CLR
 
                                                                                

Last Command: cnfrsrc 9.6.1 256 3096


Table 16-12: cnfrsrc—Parameters
Parameter Description

slot.port.vtrk

Specifies the BXM card slot and port number and virtual trunk.

Maximum PVC LCNs

The maximum number of LCNs allocated for Automatic Routing Management PVCs for this port. The range depends upon the card type (1-11771 for the BNI T/E3 and 1-15867 for the BNI OC) 256 is the default. The default is 256 only if 256 are available. If other ports and trunks on the card have been configured to use LCNs such that there are only 100 remaining, then the default value for the newly added port would be 100. In this instance trunk upping would be blocked indicating that there are not enough LCNs to support the trunk.

For trunks, there are additional LCNs allocated for Automatic Routing Management that are not configurable.

You can use the dspcd <slot> command to display the maximum number of LCNs you can configure using the cnfrsrc command for the given port. For trunks, configurable LCNs represent the LCNs remaining after the BCC has subtracted the networking LCNs needed. A trunk has 270 networking LCNs, or channels. You can use the dspcd command to display VSI channels also.

For a port card, a larger number is shown, as compared with a trunk card. This is because a trunk uses 270 networking LCNs, as compared with a port card, which uses no networking LCNs. You can use dspcd to display VSI channels also.

Setting this field to "0" would disable Automatic Routing Management PVCs on the specified port.


Note   You must specify a value greater than 0 for the Maximum PVC LCNs, Maximum PVC Bandwidth, and Maximum VSI LCNs parameters. Otherwise, you will not be able to create any Automatic Routing Management connections on a BXM card. Also, if these parameters do not have values greater than 0, you will be unable to change the connection channel amount when you configure the BXM trunk using cnftrk.

Logical Interface (slot.port [.vtrk] for trunks and slot.port for lines).

The bandwidth is logical interface based. The default value for this object is the line rate of this interface.

Maximum PVC Bandwidth

Specifies the maximum bandwidth of the port allocated for Automatic Routing Management use depends upon the card type (1-11771 for the BNI T/E3 and 1-15867 for the BNI OC); 256 is the default. The default is 256 only if 256 is available. If other ports and trunks on the card have been configured to use LCNs such that there are only 100 remaining, then the default value for the newly added port would be 100. In this instance trunk upping would be blocked indicating that there are not enough LCNs to support the trunk.

You can configure the Maximum PVC Bandwidth value for ports, but not for trunks.


Note   Note that you must specify a value greater than 0 for the Maximum PVC LCNs, Maximum PVC Bandwidth, and Maximum VSI LCNs parameters. Otherwise, you will not be able to create any Automatic Routing Management PVCs on the BXM card.

Configure PVC VCI Range

You will be prompted when configuring a port or feeder trunk only. Answer Yes or No to begin configuring the PVC VPI range. Enter Y if you are migrating PVCs on this interface to PNNI SPVCs, otherwise answer N. If you enter Y, you will be prompted for the four PVC VPI ranges.

Start of PVC VPI range x

User can define 4 VPI ranges. ALl the existing PVCs have to be using a VPI in one of the defined PVC VIP ranges.

End of PVC VPI range x

Together with Start of PVC VPI range, it defines a VPI range for PVCs.

Configure Partition

Answer yes or no to begin configuring resources for the partition. To configure Automatic Routing Management PVCs, enter n for No. You will not be prompted to enter VSI options to configure VSI partition resources.
However, if you want to configure VSI options, enter y for Yes, and you will be prompted to configure partition resources for VSI.

Partition ID

Specifies the ID number of the partition. In previous releases, use 1. In release 9.1, use 1 for the partition ID. (The default is 0. The range of values for Partition ID is 1-3 In this release, you may use 2.

Enable Partition

Answer yes or no to enable your configured partition.

Minimum VSI LCNs

The minimum number of LCNs guaranteed for this partition. Range is from 0 to card limit: 0 is the default. The VSI controller guarantees at least this many connection endpoints in the partition, provided there are sufficient free LCNs in the common pool to satisfy the request at the time the partition is added. When a new partition is added or the value is increased, it may be that existing connections have depleted the common pool so that there are not enough free LCNs to satisfy the request. The BXM gives priority to the request when LCNs are freed. The net effect is that the partition may not receive all the guaranteed LCNs (min LCNs) until other LCNs are returned to the common pool.

You can increase this value dynamically when there are enough unallocated LCNs in the port group to satisfy the increase.

You may not decrease the value dynamically. All partitions in the same port group must be deleted first and reconfigured in order to reduce this value.

To avoid this deficit condition, which could occur with maximum LCN usage by a partition or partitions, it is recommended that all partitions be configured ahead of time before adding connections. Also, it is recommended that all partitions be configured before adding a VSI controller using the addshelf command.

Maximum VSI LCNs

The total number of LCNs the partition is allowed for setting up connections. The min LCNs is included in this calculation. If max LCNs equals min LCNs, then the max LCNs are guaranteed for this partition.

Otherwise, (max - min) LCNs are allocated from the common pool on a FIFO basis.

If the common pool is exhausted, new connection setup requests will be rejected for the partition, even though the maximum LCNs has not been reached.

You may increase this value dynamically when there are enough unallocated LCNs in the port group to satisfy the increase.

You may not decrease the value dynamically. All partitions in the same port group must be deleted first and reconfigured in order to reduce this value.

Different types of BXM cards support different maximum values. If you enter a value greater than the allowed maximum, a message is displayed with the allowable maximum value.

Note that you must specify a value greater than 0 for the Maximum VSI LCNs, Maximum PVC Channels, and Maximum PVC Bandwidth parameters. Otherwise, you will not be able to add any connections on a BXM card.

Start VSI VPI

By default the LSC (for example, the 6400, 7200 or 7500 series router) will use either a starting VSI VPI of 1 or 2 for MPLS, whichever is available. If both are available, a starting VSI VPI of 1 is used. The VPI range should be 2-15 on a BPX  8620 VSI. The VSI range for MPLS on the BPX 8620 is configured as a VSI partition, usually VSI partition number 1. VSI VPI 1 is reserved for Automatic Routing Management PVCs. (This restriction applies only to trunks, not to ports. For a port, you can use any VPI value.) For a port UNI, the VPI range is 1 to 255. For a port NNI, the range is 1 to 4095. For trunks that do not have Automatic Routing Management configured, the VPI ranges are the same as for ports.

The VSI partition for MPLS should start at VPI 2. If VPI 2 is not to be used, you can use the MPLS VPI interface configuration on the LSC to override the defaults.

For trunks with Automatic Routing Management configured, the range is 2 to 4095. Always set to 2 for trunks. For ports in port mode it should be set to "1". By default the TSC (for example, 6400, 7200 or 7500 series router) will use either a starting VSI VPI of 1 or 2 for label switching, whichever is available. They default to 1.

End VSI VPI

Two VPIs are sufficient for Release 9.1, although it may be advisable to reserve a larger range of VPIs for later expansion, for example, VPIs 2-15.

The range is the <Start VSI VPI > value to 4095.

Minimum VSI Bandwidth

The minimum port bandwidth that can be used by this partition in cells per second.

The range is 0 to <Maximum Line Rate>. For example, the OC-3 line rate is 352207; 0 is the default.

Maximum VSI Bandwidth

The maximum port bandwidth that can be used by this partition. This value is used for VSI Qbin bandwidth scaling.

The range is 0 to <Maximum Line Rate>. For example, the OC-3 line rate is 352207; 0 is the default.

cnfvsiif

Use the cnfvsiif command to assign a Service Class Templates (SCT) to an interface.

Use the dspvsiif command to display a service class template assigned to an interface (VI), as well as display a summary of the resources allocated to the VSI partition on a given interface.

Assigning a Service Template to an Interface

A default service template is assigned to a logical interface (VI) when you up the interface by using upport/uptrk.

For example:

This default template has the identifier of 1. You can change the service template from service template 1 to another service template using the cnfvsiif command. The dspvsiif command allows you to display the template associated with the interface. For example:

cnfvsiif Example

You use the cnfvsiif command to assign a selected service template to an interface (VI) by specifying the template number. It has the following syntax:

  cnfvsiif <slot.port.vtrk> <tmplt_id>
Full Name

Configure a service class template and assign it to an interface

Syntax

cnfvsiif <slot.port.vtrk> <tmplt_id>

Related Commands

cnfrsrc, dsprsrc, cnfqbin, dspqbin

Attributes
Privilege Jobs Log Node Lock

1-6

Yes

Yes

BPX

Yes

Example 1

cnfvsiif 11.1 2

System Response
sw53           TN    StrataCom       BPX 8600  9.2.a5    Date/Time Not Set
 
              Port: 11.1
 
              Service Class Template ID: 2
 
 
 
 
 
 
 
 
 
                                                                                
Last Command: cnfvsiif 11.1 2
 
 
Next Command: 
 

cnfvsipart

Use the cnfvsipart command to enable or disable VSI ILMI support.

Full Name

Configure VSI paritition characteristics

Syntax

cnfvsipart <slot.port.[vtrk]> <part_id> <enable_option>


Table 16-13: cnfvsipart-Parameters
Parameter Description

slot.port.[vtrk]

Slot, port (and virtual port if applicable) of the interface.

part_id

Partition ID corresponding to the VSI partition.

enable_option

This parameter indicates whether to enable or disable VSI ILMI functionality.

Valid values:

  • Y enables the VSI ILMI session.

  • N disables the VSI ILMI session.

Related Commands

cnfrsrc, dspvsipartcnf, cnfport, cnftrk

Attributes
Privilege Jobs Log Node Lock

1-2

Yes

Yes

BPX

Yes

delctrlr

Deletes VSI capabilities on a trunk interface to which a feeder of type AAL5 is attached. Use this command to delete a controller, such as a PNNI SES controller, from a BPX node. It deletes the VSI control channels used to communicate between the VSI master on the PNNI controller and the VSI slaves on the BXM cards.

You run this command as the first step in deleting a PNNI controller from a BPX node. The second step is to run the command delshelf to delete the AAL5 feeder.

(Do not use delctrlr to delete a VSI Label Switching controller from a BPX node; you must use delshelf to delete a VSI Label Switching controller from a BPX node.)

In this release, PNNI runs on the Service Expansion Shelf (SES) hardware.

To add VSI controller capabilities onto the newly created AAL5 interface, you use the addctrlr command. You are prompted to enter the controller ID and partition ID. This creates an interface through which a PNNI controller can use the VSI protocol to control the node resources that were previously specified by using the cnfrsrc command.

You remove a PNNI controller from a BPX node by using the delctrlr command. For example, this might be a VSI controller such as an PNNI controller configured with VSI capabilities as an AAL5 interface shelf to a BPX. When you delete one of the controllers by using the delctrlr command, the master-slave connections associated with this controller are deleted. The control VCs associated with other controllers managing the same partition will not be affected.


Note   To add a VSI Label Switch Controller, you use addshelf and delshelf commands, as in releases previous to Release 9.2.

Full Name

Delete VSI capabilities from a AAL5 feeder interface

Syntax

delctrlr <slot.port> <controller id>


Table 16-14: delctrlr-Parameters
Parameter Description

slot.port

Slot and port numbers corresponding to the feeder trunk.

controller id

Controller ID number corresponding to the PNNI controller you are deleting. ID numbers should correspond to an active PNNI controller.

Valid controller values are 1 - 32

Related Commands

addctrlr, dspctrlrs, dspnode

Attributes
Privilege Jobs Log Node Lock

1

Yes

Yes

BPX

Yes

Example 1

delctrlr 10.3

Description

Delete VSI controller with interface shelf (feeder) type of AAL5 connected on trunk 10.3 from the list of controllers connected to BPX node named "night."

System Response
night          TN    StrataCom       BPX 8600    9.2.00 Apr. 11 1998 14:31 GMT
 
 
                        BPX Controllers Information
 
Trunk	    Name		     Type			    Part Id	     Ctrl Id    Ctrl IP     State
10.3 	    PAR 		      VSI     1          2          192.0.0.0   Enabled
11.1	     VSI		       VSI			     2          2          192.0.0.0   Disabled  
 
 
 
 
Last Command: delctrlr 10.3 
 
System Response
night          TN    StrataCom       BPX 8600    9.2.   Apr. 11 1998 14:31 GMT
 
 
                        BPX Controllers Information
 
Trunk	    Name		     Type			    Part Id	     Ctrl Id    Ctrl IP     State
10.3 	    PAR 		      VSI     1          2          192.0.0.0   Enabled
11.1	     VSI		       VSI			     2          2          192.0.0.0   Disabled  
 
 
 
 
Last Command: delctrlr 10.3 
 

Example 2

delctrlr <slot.port><controller_id>

Description

Deletes controller from port 3 on slot 10, with controller name E, and controller ID of 1.

System Response
 
night          TN    StrataCom       BPX 8600    9.2.00 Apr. 11 1998 14:31 GMT
 
 
                        BPX Controllers Information
 
Trunk	    Name     Type     Part Id    Ctrl Id    Ctrl IP      State
10.3     PAR 		     VSI			      1	          1          192.0.0.0    Enabled 
11.1     VSI		      VSI			      2	          2	          192.0.0.0    Disabled
 
 
 
 
Last Command: delctrlr 10.3 

delshelf

Deletes an interface shelf from a tiered network. The identifier for an interface shelf is either the trunk number or the name of the shelf. Normally, you do not execute delshelf only at the hub node, but on the IGX/AF itself. The command delshelf has the single function of letting you turn off LMI if the trunk is not allowing communication. In contrast to the deltrk command, you can execute delshelf at any time if no connections terminate at the trunk.

Deleting a Controller

You remove a controller from the node by using the delshelf command. When one of the controllers is deleted using the delshelf command, the master-slave connections associated with this controller will be deleted. The control VCs associated with other controllers managing the same partition will not be affected.

The deletion of the controller will trigger a new VSI configuration CommBus (internal BPX protocol) message. This message will include the list of the controllers attached to the node. The controller deleted will be removed from the list. This message will be sent to all active slaves in the shelf. In cluster configurations, deleting a controller will be communicated to the remote slaves by the slave directly attached through the inter-slave protocol.

While there is at least one controller attached to the node controlling a given partition, the resources in use on this partition should not be affected by a controller being deleted. Only when a given partition is disabled, the slaves will release all the VSI resources used on that partition.

Full Name

Delete an interface shelf

Syntax

delshelf <trunk> | <shelf-name>

Related Commands

addshelf, dspnode

Attributes
Privilege Jobs Log Node Lock

1

Yes

Yes

IGX, BPX

Yes

Example 1

delshelf 4.1

Description

Delete shelf trunk A241 from a BPX node.

System Response
nmsbpx23       TN    SuperUser       BPX 8600    9.2    Aug. 16 1998 13:26 PST
 
                        BPX Interface Shelf Information
 
Trunk    Name      Type      Alarm
 1.3     AXIS240   AXIS      OK
11.2     A242      AXIS      OK
 
 
 
 
 
 
 
 
 
 
 
Last Command: delshelf A241
 
Shelf has been deleted
Next Command:
 
 


Table 16-15: delshelf-Parameters
Parameter Description

trunk or shelf name

Specifies the slot and port number of the trunk or the name of the interface shelf.

delyred

This command disables Y-redundancy for the card set in the specified primary slot number. If the secondary card slot is being used as the active slot at the time you use the delyred command, the system attempts to switch back to the primary slot. The substitution takes place only if the primary slot has a complete set of cards and the cards are in a Standby or a Standby-F state (not if they are Failed). See the dspcds description for information on card states. See the addyred and dspyred commands for more information on Y-cable redundancy.

When you issue the delyred command, it always completes. If the primary card is incomplete, control will still be given to the primary card.

Full Name

Delete Y-cable redundancy

Syntax

delyred <primary slot>

Related Commands

addyred, dspyred, prtyred

Attributes
Privilege Jobs Log Node Lock

1-4

No

Yes

IGX, BPX

Yes

Example

delyred 16

Description

Disable Y-cable redundancy at slot 16.

dspchuse

The dspchuse command displays the a summary of the channel distribution in a given slot. It shows the distribution of channels between AutoRoute pvcs, networking channels, VSI management channels, and channels allocated to the VSI slave.

This command applies only to BXM cards. Previously a debug command; dspchuse is available to multiple users at all privilege levels in this release.

Full Name

Display channel distribution

Syntax

dspchuse <slot >

Related Commands

dspvsiif, dspvsipartinfo

Attributes
Privilege Jobs Log Node Lock

1-6

No

No

BPX

No

Parameters

Table 16-16: dspchuse—Parameters
Parameter
Description

max

Maximum number of channels supported on the card or port group.

used

Number of channels currently used; this includes all types of channels: networking channels, pvcs, svcs, vsi master-slave vcs, and channels allocated to VSI partitions.

avail

Number or channels still available for use.

netw

Number of network channels used. For each trunk interface (feeder trunk, physical trunk, or virtual trunk) that is upped some channels are reserved for networking. For a feeder or a physical trunk 271 channels are reserved. For a virtual trunk, the first one upped on the port will reserve 271, any subsequent virtual trunk on the same port will reserve 1 more channel.

pvc cnfg

Number of pvcs configured.

svc cnfg

Number of svcs configured.

vsi mgmt

Number of channels used for VSI master-slave vcs. Note: the sum of port group VSI management vcs may be less than the number of VSI management vcs at the card level. This is because the backplane management connection (the leg of the connection from the backplane to the slave) requires resources at the card level but not at the port group level.

vsi cnfg

VSI channels reserved for use by the slave to set up connections requested via the VSI interface. Although the configuration of the partitions is done on a per-interface basis, the pool of LCNs is managed at the card level and at the port group level.

pvc used

Channels currently used by AutoRoute connections.

vsi min

VSI min channels configured for a partition via the cnfrsrc command.

vsi max

VSI max channels configured for a partition via the cnfrsrc command.

Example 1

dspchuse 13

Description

Display channel management summary for slot 13.

System Response
sw53 		TN 	StrataCom 		BPX 8600  9.2.10 		 Jan. 10 1999 14:31 GMT
 
            Channel Management Summary for Slot 13
 
          		max 	   used 	  avail   	netw	pvc  cnfg	vsi  mgmt	 vsi cnf
 
card 13:  		16320 	 8675   	7645 	   1358	    2304     	13    	5000
port grp 	1:	8160  	5849   	2311    	813 	    1024     	12	    4000
port grp 2:		8160 	 2825 	  5335 	   545     	1280 	     0    	1000
 
          		pvc cnfg 	pvc used 	nw used 	vsi mgmt	 vsi min 	vsi max 
 
port 1:   256              	0 	   271 	      0
	part 1:                                       					1000	   4000
	part 2: 					                                      2000	   4000
port 2: 		  256 	             0    	271 	      0
port 3: 		  256              	0    	271      	12
 
This Command: dspchuse 13
 
Continue? 
 
 
Example 2

dspchuse 3

Description

Display channel management summary for slot 3.

System Response



dspctrlrs

Use the dspctrlrs command to display all VSI controllers, such as a SES PNNI controller on a BPX or IGX node. This command lists:


Note   You use addshelf and delshelf to add and delete a VSI controller such as a Label Switching Controller to a BPX node

You can also the dspnode command to display the VSI controllers on a BPX node.

Full Name

Displays all VSI controllers, for example, all PNNI controllers such as PNNI, on a BPX or IGX node.

Syntax

dspctrlrs <slot.port><controller name string><partition_id><controller_id>

Related Commands

addctrlr, addshelf, cnfctrlr, delctrlr, dspnode

Attributes
Privilege Jobs Log Node Lock

1

No

Yes

IGX, BPX

Yes

Example 1

dspctrlrs

Description

Display VSI controllers on BPX node sw174.

System Response
sw174          TRM    StrataCom       BPX 8620    9.2.xS  Sep 20 1998 14:31 GMT
 
 
                        BPX 8620 VSI controller information
 
Ctrl Id   Part Id    Trunk   Ctrlr Type    Intfc Type    Name
1        1           2.1     VSI           AAL5         SIMFDR0
 
 
 
Last Command: dspctrlrs
 

dspqbin

The dspqbin command displays the Qbin resources on a selected trunk, port, or virtual trunk. It displays the Qbin parameters currently configured for an interface, and shows whether the Qbin resources have been configured by the user OR by a template. The dspqbin command displays whether the Qbin has been configured by a user or by the template assigned to the interface. It also displays whether the Qbin has EPD enabled/disabled.

For this release, Class of Service buffer 10 is used for label switching connections. Check the queue buffer 10 configurations for port 4.1 as follows:

  dspqbin 4.1 10
Full Name

Display Qbin

Syntax

dspqbin <slot number>.<port number> [qbin-id]


Note   To display a specific Qbin configuration on the selected port, enter qbin-id as an optional parameter to the dspqbin command. For Release 9.1, use only Qbin 10 for VSI connections.

Related Commands

cnfqbin

Attributes
Privilege Jobs Log Node Lock

1-6

Yes

No

BPX

No

Example 1

dspqbin 13.1

Description

Display the current Qbin configuration on the OC-3 trunk on port 1 of slot 13 on the BPX to support MPLS.

System Response
sw53           TN    StrataCom       BPX 8600  9.2.a5    Date/Time Not Set
 
Qbin Database 11.1 on BXM qbin 10       (Configured by ATMF1 Template)

                                         (EPD Disabled on this qbin)

 
Qbin State:                   Enabled
Qbin Discard threshold:       8
Low CLP threshold:            90%
High CLP threshold:           95%
EFCI threshold:               50%
 
 
 
                                                                                
Last Command: dspqbin 11.1 10
 
 
Next Command: 
 
 
 
Example 2

dspqbin 4.1 10

Description

Display the current Qbin configuration on slot 4, port 1, Qbin 10.

System Response
sw237          TN    StrataCom       BPX 8620  9.2.L3    May  10 1999 14:42 PST 
 
Qbin Database 4.1 on BXM qbin 10        (Configured by MPLS1 Template)
                                        (EPD Enabled on this qbin)
 
Qbin State:              Enabled
Discard Threshold:       28800 cells
EPD Threshold:           95%
High CLP Threshold:      100%
EFCI Threshold:          100%
 
 
 
 
 
 
 
                                                                                
Last Command: dspqbin 4.1 10
 
 
 
Example 3

dspqbin 2.1.1 10

Description

Display Qbin 10 on slot 2, port 1, virtual trunk 1.

System Response
Qbin Database 2.1.1 on BXM qbin 10
 
Qbin Discard threshold:       			9800
Low CLP/EPD threshold:        			60%
High CLP threshold:           			80%
EFCI threshold:               			80%	
 
 
 
 
Example 4

dspqbin 13.1.1 10

Description

Display Qbin 10 configuration for virtual trunk 1, on port 1 of card slot 13.

System Response
sw237          TN    StrataCom       BPX 8620  9.2.L3    May  10 1999 14:42 PST 
 
Qbin Database 13.1.1 on BXM qbin 10     (Configured by ATMF1 Template)
                                        (EPD Disabled on this qbin)
 
Qbin State:              Enabled
Discard Threshold:       12 cells
Low CLP Threshold:       60%
High CLP Threshold:      80%
EFCI Threshold:          100%
 
 
 
 
 
 
 
                                                                                
Last Command: dspqbin 13.1.1 10
 
 


Table 16-17: dspqbin Parameters
Parameter Description

slot.port

Specifies the BXM card slot and port number.

Qbin ID

Specifies the ID number of the Qbin available for use by the LSC (MPLS Controller) for VSI. The range is 0 to 255; 0 is the default. Always use 10 in Release 9.1; use Qbin 13 in Release 9.2.

Class of Service Buffer Descriptor Template Configuration

Table 16-18 below lists parameters included in the Class of Service (CoS) Buffer (Qbin) portion of the Service Class Templates. (Note that a Qbin is a platform-specific instance (for example, BXM) of the more general Class of Service Buffer. A firmware command sends a command (message) to switch software to initialize the CoS Buffer Descriptors in the Service Class Templates. This command may contain multiple instances of Qbin number, each indicating a new Qbin configuration.


Table 16-18: Class of Service Buffer Parameters That Display on dspqbin Screen
Object (Parameter) Name Range/Values Default Description

Service Template ID

0 - 7

R

Service Class Template number for this parameter set.

Qbin Number

0 - 15

R

Identifies the target Qbin to modify.

Direction

0: Ingress

1: Egress

R

Indicates whether the Qbin configuration applies to the ingress or egress of the card.

Priority

0 - 15

R

Parameter defines the relative priority of the Qbin in relationship to the other Qbins in the VI. Zero is the highest priority and 15 is the lowest priority.

Discard Selection

1 - CLP Hysteresis

2 - Frame Discard

R

Indicates whether Qbin should perform the CLP Hysteresis or the Frame Discard option. The Qbin can only be configured to do one or the other.

Max Threshold

0 - ? cells

R

Determines the amount of cell memory to dedicated to this Qbin.

CLP High Threshold

0 - 100%

R

Parameter determines at which level in the Qbin CLP-tagged cells get discarded. Discard continues until the Qbin depth drops below the Qbin CLP Low Threshold.

CLP Low Threshold

0 - 100%

R

Parameter determines at which level in the Qbin CLP-tagged cells get admitted.

EFCI Threshold

0 - 100%

R

Parameter determines at which level in the Qbin EFCI bits get tagged in the departing cell(s).

EPD 0 Threshold

0 - 100%

R

Qbin Frame Discard threshold for CLP 0 traffic.

WFQ enable

0: Disable

1: Enable

R

Indicates whether weighted fair queueing/ traffic shaping is enabled for this Qbin.

dspqbint

Display the Qbin (class of service buffer) templates. You can enter optional parameters to display the service classes in a specified Qbin template.

Use the dspqbint command to display the service class template number assigned to an interface (VI). The dspsctmplt command has three levels of operation:

Additional service template commands you can use are:

See the sections that precede the VSI commands at the front of this chapter for more high-level information on VSI and more detailed information on service class templates in Release 9.2 and how you use them to configure connections with specified service classes.

Full Name

Display Qbin template

Syntax

dspqbint <template #><qbin #>

Description

Display a service class template number, which identifies one of the templates between 1-3, and the Qbin number.

Related Commands

dspsct, dspqbin, cnfrsrc, dsprsrc, cnfvsiif, dspvsiif

Attributes
Privilege Jobs Log Node Lock

1-6

No

No

BPX

No

Example 1

dspqbint <template #> <qbin>

Description

Displays the Qbin template number 1 for a specified Qbin (10).

System Response
 
sw53           TN    StrataCom       BPX 8600  9.2.a5    Date/Time Not Set
 
         Qbin Template:    1         Qbin:  10
 
CLP High        95        (% of Max Depth)
CLP Low         90        (% of Max Depth)
EFCI Threshold  50        (% of Max Depth)
EPD             Enabled    
Vc Shaping      Enabled    
Max Depth       2000      (micro secs)
 
 
 
 
                                                                                
Last Command: dspqbint 1 10
 
 
Next Command: 
 
 

dsprsrc

The dsprsrc command displays the partition of all the resources on the specified trunk or port. It also displays virtual trunks for a specified trunk or port. Resources not applicable to virtual trunks are not displayed.

Full Name

Display resources

Syntax

dsprsrc <slot number>.<port number>.<vtrk> [partition_id]


Note   To display a specific partition, you can enter the optional partition_id parameter for the dsprsrc command. In this release, the valid partitions are 1 and 2.

Related Commands

cnfrsrc, cnfqbin, dspqbin

Attributes
Privilege Jobs Log Node Lock

1-6

No

No

BPX

No

Example 1

dsprsrc 3.2.1

Description

Display partition resources on the OC-3 trunk on card slot 3, port 2, and virtual trunk 1 on the BPX node.

System Response
sw57           TN    SuperUser       BPX 8620    9.2    Mar. 10 1998 10:41 GMT 
 
 
Port/Trunk : 3.2.1
Template: 3
Maximum PVC LCNS:             256     Maximum PVC Bandwidth:1411679
Min Lcn(1) : 0 Min Lcn(2) : 0
Partition 1
Partition State :             Enabled
Minimum VSI LCNS:             0
Maximum VSI LCNS:             1       Used VSI LCNs: 25
Start VSI VP:                1
End VSI VPI :                 1
Minimum VSI Bandwidth :       0       Maximum VSI Bandwidth :        0
 
 
Example 2

dsprsrc 13.1

Description

Display partition resources on the OC-3 trunk on port 1 of slot 13 on the BPX to support MPLS.

System Response
sw57           TN    SuperUser       BPX 8620    9.2      Mar. 10 1997 10:41 GMT 
 
Port/Trunk:       13.1    [ACTIVE  ]
Interface:          OC-3-2
Available Channels: 16000
 
 
  Maximum PVC Channels         :   256 (default)
  Maximum PVC Bandwidth        :   352207 cps
 
  Partition ID                             : 0
  VSI Signalling VCI                 : 32 (default)
  Minimum VSI LCNs                : 0
  Maximum VSI LCNs                : 0
  Start VSI VPI                          : 0 
  End VSI VPI                            : 0
  Minimum VSI Bandwidth         : 0 cps
  Maximum VSI Bandwidth        : 0 cps
 
 
 
                                                                                
Last Command: dsprsrc 13.1
 
 
Example 3

dsprsrc 4.1 1

Description

Display partition resources on VSI trunk 4.1 (slot.port), specifying partition ID of 1. Note that if the partition is disabled, you only see the Max PVC LCNs Max. PVC Bandwidth available, and Partition ID number parameters.

System Response
 
sw237          TN    StrataCom       BPX 8620  9.2.L3    May  10 1999 14:27 PST 
 
Port/Trunk :4.1
 
Maximum PVC LCNS:            256     Maximum PVC Bandwidth:95000
 
Partition 1
 
Partition State :            Disable
 
 
 
 
 
 
 
 
                                                                                
Last Command:dsprsrc 4.1 1
 
Example 4

dsprsrc 4.1 1

Description

Display partition resources on VSI trunk 4.1, and partition ID 1. (If the partition is enabled, more parameters related to how resources are partitioned are displayed.)

System Response
sw237          TN    StrataCom       BPX 8620  9.2.L3    May  10 1999 14:35 PST 
 
Port/Trunk :4.1
 
Maximum PVC LCNS:            256     Maximum PVC Bandwidth:92000
 
Partition 1
 
Partition State :            Enabled
Minimum VSI LCNS:            20
Maximum VSI LCNS:            30
Start VSI VPI:               4
End VSI VPI :                6
Minimum VSI Bandwidth :      2000    Maximum VSI Bandwidth :       3000
 
 
 
                                                                                
Last Command:dsprsrc 4.1 1
 
Example 5

dsprsrc 4.1 1

Description

Display partition resources on VSI trunk 4.1.

System Response
n4             TN    SuperUser       BPX 8620      9.2      Apr. 4 1998  16:47 PST 
 
Port/Trunk : 4.1
 
Maximum PVC LCNS:             256     Maximum PVC Bandwidth:26000
 
Min Lcn(1) : 0 Min Lcn(2) : 0
Partition 1
 
Partition State :             Enabled
Minimum VSI LCNS:             512
Maximum VSI LCNS:             7048
Start VSI VPI:                2
End VSI VPI :                 15
Minimum VSI Bandwidth :       26000       Maximum VSI Bandwidth :        100000
 
 
                                                                                                                                                                
Last Command: dsprsrc 4.1 1
 
 
Next Command: 
 
 
Example 6

dsprsrc 3.7.10

Description

Display partition resources on VSI trunk 3.7, and partition ID 10. (If the partition is enabled, more parameters related to how resources are partitioned are displayed.)

System Response



Table 16-19: dsprsrc-Parameters
Parameter Description

slot.port

Specifies the BXM card slot and port number.

Partition ID

Specifies the ID number of the partition available for use by the LSC (MPLS Controller) for VSI. The range is 0 to 255; 0 is the default. Always use 1 in Release 9.1.

dspsct

The dspsct command displays a list of nine supported Service Class Templates (SCT).

Extended Services Types Support

The service-type parameter for a connection is specified in the connection bandwidth information parameter group. The service-type and service-category parameters determine the service class to be used from the service template.

Connection Admission Control (CAC)

For this release, when a connection request is received by the VSI Slave, it is first subjected to a Connection Admission Control process before being forwarded to the firmware layer responsible for actually programming the connection. The granting of the connection is based on the following criteria:

LCNs available in the VSI partition

QoS guarantees

When the VSI slave accepts (that is, after CAC) a connection setup command from the VSI master in the Label Switch Controller, it receives information about the connection including service type, bandwidth parameters, and QoS parameters. This information is used to determine an index into the VI's selected Service Template's VC Descriptor table thereby establishing access to the associated extended parameter set stored in the table.

Supported Service Types

The service type identifier is a 32-bit number. The service type identifier appears on the dspsct screen when you specify a service class template number and service type; for example:

  dspsct <2> <vbrrt1>

A list of supported service templates and associated Qbins, and service types is shown in Table 16-20.


Table 16-20: Service Template and Associated Qbin Selection
Template Type Service Type ID Service Type Parameters Associated Qbin

VSI Special Types

0x0001

0x0002

Default

Signaling

13

10

ATMF Types

ATMF1 and

ATMF2 templates

(for PNNI controllers)

0x0100

0x0101

0x0102

0x0103

0x0104

0x0105

0x0106

0x0107

0x0108

0x0109

0x010A

0x010B

cbr.1

vbr.rt1

vbr2.rt

vbr3.rt

vbr1.nrt

vbr.2nrt

vbr.3nrt

ubr.1

ubr.2

abr

cbr.2

cbr.3

ATM Forum (ATMF) Types

See dspsct command for sample parameters for various service types, such as VbrRt1, Cbr1, and so on.

10

11

11

11

12

12

12

13

13

14

10

10

MPLS Types

(for MPLS controllers)

0x0001

0x0200

0x0201

0x0202

0x0203

0x0204

0x0205

0x0206

0x0207

0x0210

Default

Signaling

label cos0

label cos1

label cos2

label cos3

label cos4

label cos5

label cos6

label cos7

label ABR

13

10

10

11

12

13

10

11

12

13

14

Details of Connection (VC) Parameters Used in Service Class Templates

Listed below is some detailed information on connection (VC) parameters used in service class templates. Some of these parameters may appear on the dspsct display.

Qbin # 
Description 								CoS Buffer (Qbin) to use for this CoS
Range/Values: 10 - 15 (for Release 9.2)
Units: enumeration UPC Enable Description: Enable/Disable Policing function. The first 2 values are consistent with the definition for the older cards. Option #2 and #3 are new and provide the ability to turn on policing on just GCRA #1 (PCR policing) or #2 (SCR policing). Range/Values: 0 -3
0: Disable both GCRAs
1: Enable both GCRAs
2: Enable GCRA #1 only (PCR policing)
3: Enable GCRA #2 only (SCR policing) Units: enumeration UPC CLP Selection Description: Selects processing of policing Buckets based on the CLP bit. Range/Values: 0 -2
0 - Bk 1: CLP (0+1), Bk 2: CLP (0)
1 - Bk 1: CLP (0+1), Bk 2: CLP (0+1)
2 - Bk 1: CLP (0+1), Bk 2: Disabled Units: enumeration Policing Action (GCRA #1) Description: Indicates how cells that fail the second bucket (SCR bucket) of the policer should be handled, if policing is enabled. Range/Values: 0 - Discard
1 - Set CLP bit
2 - Set CLP of untagged cells, disc. tag'd cells Units: enumeration Policing Action (GCRA #2) Description: Indicates how cells that fail the second bucket (SCR bucket) of the policer should be handled, if policing is enabled. Range/Values: 0 - Discard
1 - Set CLP bit
2 - Set CLP of untagged cells, disc. tag'd cells Units: enumeration PCR Description: Peak Cell Rate; used as default value if not supplied in VSI connection request. Range/Values: 0 - 100 Units: cells/sec MCR Description: Minimum Cell Rate; used as default value if not supplied in VSI connection request. Range/Values: 0 - 100 Units: cells/sec SCR Description: Sustained Cell Rate; used as default value if not supplied in VSI connection request. Range/Values: 0 - 100 Units: cells/sec ICR Description: Initial Cell Rate . Used only for ABR VCs to set initial ACR value after idle traffic period. Range/Values: 0 - 100 Units: cells/sec MBS Description: Maximum Burst Size - used to set bucket depth in policer function. Range/Values: 1 - 5M Units: cell count CoS Min BW Description: Bandwidth reserved for this Class of Service; used to initialize the CoS Buffer (Qbin) Minimum Service Rate (HW param. = ICG), and for CAC purposes (subject to CAC treatment type). Range/Values: 0% - 100% Units: % of Partition Min BW. CoS Max BW Description: Maximum value allowed for the sum of VC Min. BW's for this CoS; used by CAC (subject to CAC treatment type). Range/Values: 0% - 100% Units: % of Partition Max BW Scaling Class Description: Scaling table used for modifying per-VC thresholds under VI or Global cell-memory congestion. Range/Values: choices are 0 - 3, 0: CBR
1: VBR
2: ABR
3: UBR Units: enumeration CAC Treatment Description: Connection Admission Control algorithm used by this CoS Range/Values: 0 - 256 0: No CAC performed; all connections admitted. 1: LCN_CAC; check for LCN availability only; no BW consideration. 2: MINBW_CAC; LCN + simple min. BW test (sum_of_VC_min_BW <= CoS_max_BW) 3: CAC_2 w/ overbooking allowed 4: ECR_CAC; LCN + ECR calculation (from table) & BW test (sum_of VC_ECR <= Cos_max_BW). 5: CAC_4 w/ overbooking allowed 6: MEASURED_CAC; LCN + ECR calculation (from dynamic measurement) & BW test (sum_of VC_ECR <= Cos_max_BW). Units: enumeration VC Max Description: Maximum VC-cell-count threshold; all cells are discarded on a VC when this threshold has been exceeded. Range/Values: 0 - VI_max_cell_count Units: cell count VC CLPhi Description: VC cell count above which CLP=1 cells are discarded Range/Values: 0 - 100 Units: % of VC Max threshold VC CLPlo Description: VC cell count below which CLP=1 cells are no longer discarded (discards having begun when CLPhi was exceeded). Range/Values: 0 - 100 Units: % of VC Max threshold VC EPD Description: VC cell count above which AAL-5 frames are discarded Range/Values: 0 - 100 Units: % of VC Max threshold VC EFCI Description: VC cell count above which congestion notification is activated Range/Values: 0 - 100 Units: % of VC Max threshold VC Discard Selection Description: Choice of frame-based discard (EPD) or CLP-hysteresis Range/Values: 0 - 1
0: CLP Hysteresis
1: EPD Units: enumeration VSVD/FCES Description: For ABR VC's, enable/disable Virtual Source/Virtual Destination (VSVD) and/or Flow Control on External Segments (FCES) functionality Range/Values: 0 -2
0: None
1: VSVD
2: VSVD w/ FCES Units: enumeration ADTF ABR only parameter Description: ACR decrease time factor; idle time before ACR -> ICR Range/Values: 10 - 1023 Units: milliseconds RDF ABR only parameter Description: Rate Decrease Factor
ACR = ACR - (ACR * RDF) Range/Values: 2 - 512, in powers of 2 Units: Inverse decrease factor RIF ABR only parameter Description: Rate Increase Factor
ACR = ACR + (PCR * RDF) Range/Values: 2 - 512, in powers of 2 Units: Inverse decrease factor NRM ABR only parameter Description: Number of data cells between FRM cells Range/Values: 2 - 512, in powers of 2 Units: cells TRM ABR only parameter Description: Range/Values: Units: CDF ABR only parameter Description: Range/Values: Units: TBE ABR only parameter Description: Range/Values: Units: FRTT ABR only parameter Description: Range/Values: Units:
Full Name

Display service class template (SCT)

Syntax

dspsct [template #][service_type]

Related Commands

dspqbint, cnfvsiif, dspvsiif

Attributes
Privilege Jobs Log Node Lock

1-6

No

No

BPX

No

Example 1

dspsct

Description

Displays all the templates in the node.

System Response
sw53           TN    StrataCom       BPX 8620  9.2.a5    May 11 1999 14:24 PST 
 
                         Service Class Templates
 
Template   Name
 
   1       MPLS1
   2       ATMF1
   3       ATMF2
 
 
                                                                                
Last Command: dspsct  
 
 
Next Command: 
 
 
 
Example 2

dspsct 2

Description

Display service class template 2, which displays service classes (also referred to as service categories or service sub-categories) for the ATMF1 template, along with designated Qbins (class of service buffers).

System Response
sw237          TN    StrataCom       BPX 8620	      9.2.1G    June 9	1999  17:48	PST
 
           Service Class Map for ATMF1 Template
 
Service Class    Qbin    Service Class    Qbin	         Service Class	    Qbin
 
Default       13          Cbr2          10
VbrRt1        11          Cbr3          10
VbrRt2        11
VbrRt3        11
VbrNRt1       12
VbrNRt2       12
VbrNRt3       12
Ubr1          13
Ubr2          13
Abr           14
Cbr1          10
 
Last Command: dspsct 2
 
 
Next Command:
 
 
Example 3

dspsct 3

Description

Display service class template 3, which displays service classes (also referred to as service categories or service sub-categories) for the ATMF1 template, along with designated Qbins (class of service buffers).

System Response
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  17:45 PST 
 
         Service Class Map for ATMF2 Template
 
Service Class    Qbin    Service Class    Qbin    Service Class   Qbin
 
    Default       13          Cbr2          10
    VbrRt1        11          Cbr3          10
    VbrRt2        11
    VbrRt3        11
    VbrNRt1       12
    VbrNRt2       12
    VbrNRt3       12
    Ubr1          13
    Ubr2          13
    Abr           14
    Cbr1          10
                                                                                
Last Command: dspsct 3
 
 
Next Command: 
 
Example 4

dspsct 2 vbrrt1

Description

Display service class template (SCT) for template number 2 called vbrrt1.

System Response
sw53           TN       BPX 8620  9.2.a3      Apr. 13 1999     17:30 PST 
 
         Service Template:ATMF1 (2)     Service Type:  VbrRt1 (101)
 
Service Category                   VbrRt (101)        
Qbin                               11                 
UPC Enable                         GCRA_1_2           
UPC CLP Selection                  CLP01_CLP01        
Policing Action 1                  DISCARD            
Policing Action 2                  DISCARD            
Sustained Cell Rate                100               (% of PCR)
Maximum Burst Size                 1024              (cells)
Scaling Class                      Scaled 3rd         
CAC Treatment                      CAC4               
VC Max Threshold                   1280              (cells)
VC Dscd Selection                  Hystersis          
VC CLP High                        80                (% of Vc MAX
Threshold)
                                                                               
Last Command:dspsct 2 vbrrt1  
 
 
 
sw236          TRM   StrataCom       BPX 8620  9.2.a8    May  11 1999 14:35 PST 
 
        Service Template:ATMF1 (2)     Service Type:  VbrRt1 (101)
 
VC CLP Low                         35                (% of Vc MAX Threshold)
Cell Delay Variation Tolerance     250000             
 
 
 
 
 
 
 
 
 
 
 
                                                                                
Last Command:dspsct 2 vbrrt1
 
 
Example 5

dspsct 2 Abr

Description

Display all the parameters of the service class template ID 2, specified by Abr.

System Response
sw53           TN    StrataCom       BPX 8600  9.2.a5    Date/Time Not Set
 
         Service Template: ATMF1 (2)      Class: Abr (104)  
 
Service Class Type                 109                
Qbin                               14                 
UPC Enable                         2                  
UPC CLP Selection                  2                  
Policing Action 1                  2                  
Peak Cell Rate                     100               (%age of PCR)
Minimum Cell Rate                  50                (% of PCR)
Initial Cell Rate                  50                (% of PCR)
Scaling Class                      0                  
CAC Treatment                      2                  
VC Max Threshold                   0                 (cells)
VC CLP High                        75                (% of Vc MAX Threshold)
VC CLP Low                         30                (% of Vc MAX Threshold)
                                                                                
This Command: dspsct 2 abr 
 
Continue? 
Example 6

dspsct 1 Default

Description

Displays the parameters for service class template 1 (the MPLS1 service class template), for the Default service type.

System Response
 
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  17:53 PST 
 
         Service Template: MPLS1 (1)     Service Type:   Default (1)
 
Service Category                   Default (1)        
Qbin                               13                 
UPC Enable                         NONE               
Scaling Class                      Scaled 1st         
CAC Treatment                      LCN                
VC Max Threshold                   61440             (cells)
VC Dscd Selection                  EPD                
VC CLP High                        100               (% of Vc MAX Threshold)
VC EPD                             40                (% of Vc MAX Threshold)
Cell Delay Variation Tolerance     250000             
 
 
 
                                                                                
Last Command: dspsct 1 Default
 
 
Next Command: 
Example 7

dspsct 1 Signaling

Description

Displays the parameters for service class template 1 (the MPLS1 service class template), for the Signaling service type.

System Response
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  17:57 PST 
 
         Service Template: MPLS1 (1)     Service Type:   Signaling (2)
 
Service Category                   Signaling (2)      
Qbin                               10                 
UPC Enable                         NONE               
Scaling Class                      Scaled 1st         
CAC Treatment                      LCN                
VC Max Threshold                   0                 (cells)
VC Dscd Selection                  Hystersis          
VC CLP High                        75                (% of Vc MAX Threshold)
VC CLP Low                         30                (% of Vc MAX Threshold)
 
 
 
 
                                                                                
Last Command: dspsct 1 signaling
 
 
Next Command: 
 
                      CD                                             MAJOR ALARM
 
Example 8

dspsct 1 Signaling

Description

Displays the parameters for service class template 1 (the MPLS1 service class template), for the Signaling service type.

System Response
 
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  17:59 PST 
 
         Service Template: MPLS1 (1)     Service Type:   Tag0 (200)
 
Service Category                   Tag0 (200)         
Qbin                               10                 
UPC Enable                         NONE               
Scaling Class                      Scaled 1st         
CAC Treatment                      LCN                
VC Max Threshold                   61440             (cells)
VC Dscd Selection                  EPD                
VC CLP High                        100               (% of Vc MAX Threshold)
VC EPD                             40                (% of Vc MAX Threshold)
 
 
 
 
                                                                                
Last Command: dspsct 1 Tag0
 
 
Next Command: 
 
 
Example 9

dspsct 1 Tag0

Description

Displays the service classes in the service template 3, which is a service class template for use with a PNNI controller.

System Response
 
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  17:59 PST 
 
         Service Template: MPLS1 (1)     Service Type:   Tag0 (200)
 
Service Category                   Tag0 (200)         
Qbin                               10                 
UPC Enable                         NONE               
Scaling Class                      Scaled 1st         
CAC Treatment                      LCN                
VC Max Threshold                   61440             (cells)
VC Dscd Selection                  EPD                
VC CLP High                        100               (% of Vc MAX Threshold)
VC EPD                             40                (% of Vc MAX Threshold)
 
 
 
 
                                                                                
Last Command: dspsct 1 Tag0
 
 
Next Command: 
 
 
 
Example 10

dspsct 1 Tag1

Description

Displays the service classes in the service template 3, which is a service class template for use with a PNNI controller.

System Response
 
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  18:02 PST 
 
         Service Template: MPLS1 (1)     Service Type:   Tag1 (201)
 
Service Category                   Tag1 (201)         
Qbin                               11                 
UPC Enable                         NONE               
Scaling Class                      Scaled 1st         
CAC Treatment                      LCN                
VC Max Threshold                   61440             (cells)
VC Dscd Selection                  EPD                
VC CLP High                        100               (% of Vc MAX Threshold)
VC EPD                             40                (% of Vc MAX Threshold)
 
 
 
 
                                                                                
Last Command: dspsct 1 Tag1
 
 
Next Command: 
 
 
Example 11

dspsct 1 Tag2

Description

Displays the service classes in the service template 3, which is a service class template for use with a PNNI controller.

System Response
 
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  18:02 PST 
 
         Service Template: MPLS1 (1)     Service Type:   Tag1 (201)
 
Service Category                   Tag1 (201)         
Qbin                               11                 
UPC Enable                         NONE               
Scaling Class                      Scaled 1st         
CAC Treatment                      LCN                
VC Max Threshold                   61440             (cells)
VC Dscd Selection                  EPD                
VC CLP High                        100               (% of Vc MAX Threshold)
VC EPD                             40                (% of Vc MAX Threshold)
 
 
 
 
                                                                                
Last Command: dspsct 1 Tag2
 
 
Next Command: 
 
 
 
Example 12

dspsct 1 VbrRt1

Description

Displays the service classes in the service template 3, which is a service class template for use with a PNNI controller.

System Response
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  18:09 PST 
 
         Service Template: ATMF1 (2)     Service Type:   VbrRt1 (101)
 
Service Category                   VbrRt (101)        
Qbin                               11                 
UPC Enable                         GCRA_1_2           
UPC CLP Selection                  CLP01_CLP01        
Policing Action 1                  DISCARD            
Policing Action 2                  DISCARD            
Sustained Cell Rate                100               (% of PCR)
Maximum Burst Size                 1024              (cells)
Scaling Class                      Scaled 3rd         
CAC Treatment                      CAC4               
VC Max Threshold                   1280              (cells)
VC Dscd Selection                  Hystersis          
VC CLP High                        80                (% of Vc MAX Threshold)
                                                                                
This Command: dspsct 2 VbrRt1
 
 
Continue? 
 
Example 13

dspsct 1 VbrRt1

Description

Displays the service classes in the service template 3, which is a service class template for use with a PNNI controller.

System Response
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  18:11 PST 
 
         Service Template: ATMF1 (2)     Service Type:   Cbr1 (100)
 
Service Category                   Cbr (100)          
Qbin                               10                 
UPC Enable                         GCRA_1             
UPC CLP Selection                  CLP01              
Policing Action 1                  DISCARD            
Scaling Class                      Scaled 4th         
CAC Treatment                      CAC4               
VC Max Threshold                   160               (cells)
VC Dscd Selection                  Hystersis          
VC CLP High                        80                (% of Vc MAX Threshold)
VC CLP Low                         35                (% of Vc MAX Threshold)
Cell Delay Variation Tolerance     250000             
 
                                                                                
Last Command: dspsct 2 Cbr1
 
 
Next Command: 
 
 

dspvsiif

You can use the dspvsiif command to display a service class template assigned to an interface (VI). You can also display a summary of the resources allocated to the VSI partition on a given interface. Multiple users are allowed to use the dspvsiif at one time.

Example

After using cnfvsiif command to assign a selected service class template to an interface, you can use the dspvsiif command to display the type of service template assigned to an interface (VI). It has the following syntax:

   dspvsiif <slot.port.vtrk>
Full Name

Display a service class template assigned to an interface.

Syntax

dspvsiif <slot.port.vtrk> <tmplt_id>

Related Commands

cnfrsrc, dsprsrc, cnfqbin, dspqbin

Attributes
Privilege Jobs Log Node Lock

1-6

Yes

Yes

IGX, BPX

Yes

Example 1

dspvsiif 13.1.1

Description

Display the service class template ID assigned to an interface configured on slot 13, port 1, virtual trunk of 1. In this case, service class template 2 has been assigned to this interface.

System Response
 
 
sw237          TN    StrataCom       BPX 8620  9.2.L3    May  10 1999 14:39 PST 
 
Virtual Trunk :13.1.1
 
Service Class Template ID:2
 
 
 
 
 
 
 
 
 
                                                                                
Last Command:dspvsiif 13.1.1 
 
Example 2

dspvsiif 11.1 2

Description

Display a service class template assigned to an interface.

System Response
sw53           TN    StrataCom       BPX 8600  9.2.30 Date/Time Not Set
 
Port: 11.1
 
Service Class Template ID: 2
 
 
VSI Partitions
                channels              bw             vpi
Part   E/D   min   max      min   max      start end   ilmi
 1     E     1000  4000     10000 40000    240   249   Off
 2     E     2000  4000     20000 40000    250   255   On
 
 
 
 
 
                                                                                
Last Command: dspvsiif 11.1 2
 
 
Next Command: 
 

dspvsipartcnf

Use this command to display VSI partition characteristics. It displays information about only VSI ILMI functionality. This command displays:

If no partition is specified, this command displays the above information about all the VSI partitions and also the Sys_Id downloaded to the BXM card for ILMI functionality.

Full Name

Display VSI partition characteristics

Syntax

dspvsipartcnf <slot.port.[vtrk]> [partition_id]


Table 16-21: dspvsipartcnf—Parameters
Parameter Description

slot.port.[vtrk]

Slot, port (and virtual port if applicable) of the interface.

partition_id

Partition ID corresponding to the VSI partition. This parameter is optional and if not specified, this command will display information about all VSI partitions.

Related Commands

cnfrsrc, cnfvsipart, cnfport, cnftrk

Attributes
Privilege Jobs Log Node Lock

1-2

Yes

No

BPX

Yes

dspvsipartinfo

Use the dspvsipartinfo command to display VSI statistics for a particular active partition on an interface. You can use the dspvsipartinfo command on only one partition at a time, to get VSI statistics on an interface (can be a port or virtual trunk). You can optionally specify an interval in seconds, which will display VSI statistics for the specified active partition every x seconds. The command shows you some of the same parameters that display on the cnfrsrc screen, such as Min LCNs and Max LCNs, Used LCNs and Available LCNs, and Min BW, Max BW, and Used BW.

The command dspvsipartinfo also displays a line that provides slave redundancy status. It tells you whether the standby card is in synch with the active card. You must have cards in Y-redundancy configuration for this line to display.

Multiple users may use the dspvsipartinfo command at the same time.

Job mode is not allowed.

Full Name

Display VSI statistics per partition

Syntax

dspvsipartinfo <interface>.<partition>[<interval>]

<interface>             the slot.port.[vtrk] of the interface being monitored.

<partition>             partition id for which information is to be displayed.

<interval>               the refresh interval for displaying data. Range:1-60 seconds. Default: 1 second.

Related Commands

cnfrsrc, dsprsrc, cnfvsiif, dspvsiif

Attributes
Privilege Jobs Log Node Lock Multiple Users

1-6

No

No

BPX

Yes

Yes


Table 16-22: dspvsipartinfo—Field Description
Parameter Description

Min BW

Configured minimum bandwidth for this partition (for reference only).

Max BW

Configured maximum bandwidth for this partition (for reference only).

Used BW

Bandwidth currently used by connections on this partition.

Available BW

Bandwidth currently available to connections on this partition. This is determined based on the minimum and maximum bandwidth configured for the partition and the bandwidth currently available in the common pool.

Min Lcns

Configured minimum LCNs for this partition (for reference only).

Max Lcns

Configured maximum LCNs for this partition (for reference only).

Used Lcns

Number of LCNs currently used by connections in this partition.

Available Lcns

Number of LCNs available to this partition. This is determined based on the minimum and maximum LCNs configured for the partition and the LCNs currently available in the common pool.

Example 1

dspvsipartinfo 3.1 1 10

Description

Display VSI statistics for slot 3, port 1 for interface configured on partition ID 1, at an interval of every 10 seconds.

System Response
sw237          TN    StrataCom       BPX 8620  9.2.1G    June 9 1999  17:32 PST 
 
            VSI Resources Status for trunk  3.1 Partition 1
 
Min Lcns       : 0           Min BW (cps)     : 0
Max Lcns       : 20          Max BW (cps)     : 0
Used Lcns      :             Used BW (cps)    :
Available Lcns :             Available BW(cps):
 
 
 
Next Command: dspvsipartinfo 3.1 1
 
Example 2

dspvsipartinfo 11.1 2 10

Description

Display VSI statistics for port 1 for interface configured on partition ID 2, at an interval of every 10 seconds.

sw53 		TN 	StrataCom 		BPX 8600  9.2.10 		 Jan. 10 1999 14:31 GMT
 
 
            VSI Resource Status for port 11.1 Partition 2
 
Min Lcns         1000		        Min BW (cps) 			      20000
Max Lcns         4000        		Max BW (cps)       40000
Used Lcns        500		         Used BW (cps)      20000
Available Lcns:			: 1000	        Available BW(cps)   10000
 
 
 
This Command: dspvsipartinfo 11.1 2 10
 
 
Hit DEL key to quit:
 
 
Example 3

dspvsipartinfo 4.1 1

Description

Display VSI statistics for slot 4, port 1 for interface configured on partition ID 1.

System Response
sw237          TN    StrataCom       BPX 8620  9.2.L3    May  10 1999 14:58 PST 
 
            VSI Resources Status for trunk  4.1 Partition 1          Snapshot
 
Min Lcns       :20          Min BW (cps)      :2000
Max Lcns       :30          Max BW (cps)      :3000
Used Lcns      :            Used BW (cps)     :
Available Lcns :             Available BW(cps):
 
 
 
 
 
 
 
                                                                                
Last Command:dspvsipartinfo 4.1 1
 
 

dspvsich

The dspvsich command is a debug command that displays VSI logical connections. These VSI logical connections are also sometimes referred to as management LCNs (1-6, 9-15). The dspvsich command displays the LCN number, type of channel (for example, interslave, master-slave, or intershelf); the destination slot, and destination LCN.

(Note that you must have debug level privileges to use this command, that is, either Service or StrataCom level privileges. Check with the TAC for assistance in accessing these commands.)

In this release, this command displays the control_VPI and control_VCI_start of the particular controller.

Full Name

Display VSI logical connections

Syntax

dspvsich <slot>

Description

Display the VSI channels (or LCNs) on the specified slot.

Related Commands

cnfqbin

Attributes
Privilege Jobs Log Node Lock

Service Level

No

No

BPX

No

Example 1

dspqbin 13.1

Description

Display the current Qbin configuration on the OC-3 trunk on port 1 of slot 13 on the BPX to support MPLS (Multiprotocol Label Switching).

Example 2

dspvsich 4

Description

Display VSI management channels (or LCNs) on slot 4.

System Response
sw237          TN    StrataCom       BPX 8620  9.2.a3    June 16 1999 05:10 PST 
 
                             VSI lcns for Slot 4
 
     lcn             type         dest_slot   dest_lcn    vpi     vci 
    272       slave-end msvc        13         546        -       -
    16365     control-port msvc     local      -          1       23
    16364     control-port msvc     3          16365      1       22
    16374     control-port msvc     13         8173       1       32
    16349     interslave            3          16350      -       -
    16359     interslave            13         8158       -       -
 
 
 
                                                                                
Last Command: dspvsich 4
 
 
 


Table 16-23: dspvsich—Parameters
Parameter Description

slot.port

Specifies the BXM card slot and port number.

Qbin ID

Specifies the ID number of the Qbin available for use by the LSC (MPLS Controller) for VSI. The range is 0 to 255; 0 is the default. Always use 10 in 9.1.

dspyred

Displays information for Y-cable pairings. A single slot can be specified, or all pairings are displayed when no slot is specified. Slot numbers appearing in high intensity indicate active card status. Front card, back card, and channel configuration conflicts appear in reverse video. A conflict occurs when the port interfaces are different for corresponding ports in a redundant slot pair. The output display contains the following information:

Remaining columns (Channel Configuration) describe the channel configurations when appropriate.

Full Name

Display Y-cable redundancy

Syntax

dspyred [slot]

Related Commands

addyred, delyred, prtyred

Attributes
Privilege Jobs Log Node Lock

1-4

No

No

IGX, BPX

No

Example 1

dspyred

Description

Display Y-redundancy for all cards.

System Response
beta           TRM   YourID:1        IGX 8420    9.2    Aug. 15 1998 14:28 MST 
                                                                                
     Slot Other Front  Back   Channel Configuration                             
Slot Type Slot  Card   Card     1    2    3    4    5    6    7    8            
25   Pri  26    SDP    RS232   DCE  DCE  DCE  DCE                               
26   Sec  25    SDP    RS232   DCE  DCE  DCE  DCE                               
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
 
                                                                                
Last Command: dspyred                                                           
                                                                                
                                                                                
Next Command:   
                                                             


hometocprevnextglossaryfeedbacksearchhelp
Posted: Fri Sep 29 13:43:51 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.