To display the Card Configuration dialog for this device (using the rear or front view), right-click on the card to display the card "Configure" pop-up menu, then select Configure.
Use this dialog to display UFM-U card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 15-1.
| Parameter | Description |
|---|---|
Slot No | Identifies the slot the card is in. |
Card Status | Status of the card. Examples are:
|
FrontCard Type | Identifies the type of front card. In this case, it is an NTM. |
Front Card Serial# | Serial number on the front card. |
FrontCard Revision | Model, hardware revision, and firmware revision of the front card. |
Card Y-RedStatus | Card Y-Redundancy status. The values can be one of: primary, secondary, null. |
AssocCard for Y-red | Associated slot for this card's Y-Redundancy. If the Card Y-RedStatus is primary, the secondary card index displays in this field. If the Card Y-RedStatus is secondary, the primary slot index displays in this field. If Card Y-RedStatus is null, a zero (0) appears in this field. |
BOOTId | Boot ID of the processor card. If the card is not a processor card, this field is blank. |
No. Ports (Front Card) | Number of ports on the front card. |
![]() |
Note This is not a configurable dialog. |
Use this dialog to view back card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 15-2.
| Parameter | Description |
|---|---|
Slot No. | Number that identifies the slot the card is installed in. |
Card Status | Status of the card. Examples are:
|
BackCard Type | Back card type. |
BackCard Serial # | Serial number on the card. |
BackCard Revision | Model number and hardware revision of the back card. |
No. Ports (Backcard) | Number of ports on the back of the card. |
![]() |
Note The parameters in this dialog cannot be configured. |
To open the Port Configuration dialog, right-click on a port (rear view) to display the "Configure" pop-up menu, then click Configure. The Port Configuration dialog is displayed. From the Category pull-down menu, select one of the following options:
These dialogs are described in the subsections that follow.
To display and configure logical ports on a UFM-U card, select Logical Port Config from the Category>Ports menu. The Logical Port Config dialog displays as shown in Figure 15-1.

The parameters are described in Table 15-3.
| Parameter | Description |
|---|---|
Card Number | Number that identifies the slot the card is in. |
Port Number | Number of the line. |
Line number | Line number. |
Admin Status | Admin status of the port. Choose one from the pop-up menu:
|
Operational Status | Operational status of the port. |
Port Speed | Port speed in Kbps. |
Number of Channels | Number of channels. |
Channel Speed | Channel speed in Kbps. |
Starting channel | Starting channel number. |
IDE to DE map | Choose yes or no from the pop-up menu. |
LMI Operation Mode | Choose one from the pop-up menu:
|
To display and configure Port real-time Counters on a UFM-U card, select IGX: Port Real-Time Counters from the Category>Ports menu. The IGX: Port Real-Time Counters dialog displays as shown in Figure 15-2.

The parameters are described in Table 15-4.
| Parameter | Description |
Card Number | Card number. |
Port Number | Port number. |
Rx Bytes | Traffic received in bytes. |
Tx Bytes | Traffic transmitted in bytes. |
Tx Frms | Traffic transmitted in frames. |
Rx Frms | Traffic received frames. |
Tx FECN Frms | The total number of frames transmitted with the FECN bit set. |
Tx BECN Frms | The total number of frames transmitted with the BECN bit set. |
# DE Frms Dropped | The total number of DE frames dropped due to queue threshold met. |
Rx Frm CRC Errs | The total number of frames received with CRC errors. |
Frms with Illegal Fmts | The total number of frames received with incorrect illegal formats. |
Rx Alignment Err Frms | The total number of frames dropped with non-bytes aligned payload. |
Rx Illegal Len Frms | The total number of frames received with illegal length. |
# DMA Overruns | The total number of DMA overruns. |
Unknown DLCIs | The total number of received frames with invalid/unknown DLCI dropped. |
CLLM Tx Bytes | The total number of CLLM bytes transmitted. |
CLLM Rx Bytes | The total number of CLLM frames received. |
CLLM Tx Frms | The total number of CLLM frames transmitted. |
CLLM Rx Frms | The total number of CLLM frames received. |
CLLM Failures | The total number of CLLM failures. |
LMI Fail Frames | The total number of LMI failure frames. |
LMI Fail Bytes | The total number of LMI failure bytes. |
![]() |
Note This is not a configurable dialog. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()