The Universal Frame Model (UFM-C) supports either 4 or 8 T1 or E1 ports per backcard. The UFM-4C supports 4 ports regardless of the presence of the eight connectors on the UFI backcard. The UFM-8C supports all 8 ports. Both models of the UFM-C support 1 to 24 or 1 to 31 DS0s per physical line.
The UFM-C can also operate unchannelized for E1 only, with 32 DS0s constituting one unchannelized E1. In the unchannelized mode, one logical E1 port maps to one E1 line.
To display the Card Configuration dialog for this device (using the rear or front view), right-click on the card to display the card "Configure" pop-up menu, then select Configure.
Use this dialog to display UFM-C card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 14-1.
| Parameter | Description |
|---|---|
Slot No | Identifies the slot the card is in. |
Card Status | Status of the card. Examples are:
|
FrontCard Type | Identifies the type of front card. In this case, it is an NTM. |
Front Card Serial# | Serial number on the front card. |
FrontCard Revision | Model, hardware revision, and firmware revision of the front card. |
Card Y-RedStatus | Card Y-Redundancy status. The values can be one of: primary, secondary, null. |
AssocCard for Y-red | Associated slot for this card's Y-Redundancy. If the Card Y-RedStatus is primary, the secondary card index displays in this field. If the Card Y-RedStatus is secondary, the primary slot index displays in this field. If Card Y-RedStatus is null, a zero (0) appears in this field. |
BOOTId | Boot ID of the processor card. If the card is not a processor card, this field is blank. |
No. Ports (Front Card) | Number of ports on the front card. |
![]() |
Note This is not a configurable dialog. |
Use this dialog to view backcard characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 14-2.
| Parameter | Description |
|---|---|
Slot No. | Number that identifies the slot the card is installed in. |
Card Status | Status of the card. Examples are:
|
BackCard Type | Backcard type. |
BackCard Serial # | Serial number on the card. |
BackCard Revision | Model number and hardware revision of the backcard. |
No. Ports (Backcard) | Number of ports on the back of the card. |
![]() |
Note The parameters in this dialog cannot be configured. |
To open the Line Configuration dialog, right-click on a line (rear view) to display the "Configure" pop-up menu, then click Configure. The Physical Line Configuration dialog is displayed. From the Category pull-down menu, select one of the following options:
These dialogs are described in the subsections that follow.
To display and configure physical lines on a UFM-C card, select IGX: Physical Line Configuration from the Category menu. The parameters are described in Table 14-3.
| Parameter | Description |
Card | Number that identifies the slot the card is in. |
Line | Number of the line. |
Interface Type | Line Interface type. |
Admin Status | Choose one from the pop-up menu:
|
Service | Choose framrelay from the pop-up menu. The other options do not apply to the UFM-C interface. |
To display and configure lines on a UFM-C card, select IGX: Line Config from the Category menu. The IGX: Line Config dialog displays as shown in Figure 14-1.

The parameters are described in Table 14-4.
| Parameter | Description |
|---|---|
Card | Number that identifies the slot the card is in. |
Line | Number of the line. |
Line Alarm Status | The status of the line alarm. Can be one of: major, minor, clear, deact (deactivated). |
Line Alarm Status Information | Information on the status of the line alarm. Can be one of:
|
Line Type | The type of line. Can be one of:
|
Line Coding | The line coding. Can be one of:
|
Transmit Clock Source | The transmit clock source. Can be
|
![]() |
Note This is not a configurable dialog. |
The UFM-C Logical Port menu item provides two port configuration dialogs:
Use the Logical Port Mod/Del dialog to configure Logical Ports on a UFM-C card. (See Figure 14-2.)

The parameters are described in Table 14-5.
| Parameter | Description |
|---|---|
Card Number | Identifies the slot the card is in. |
Port Number | Number of the logical port for that line. |
Line number | Number of the line. |
Admin Status | Admin status for the line. Choose one from the pop-up menu:
|
Operational Status | The operational status of the port. Can be active, failed, inactive, looped, or unknown. |
Port Speed | The baud rate of the port. |
Number of channels | Number of channels for the port. |
Channel Speed | The channel speed (Frame Relay T1/E1 interface only). Choose one of the following from the pop-up menu:
|
Starting channel | Starting channel. |
IDE to DE map | A flag indicating whether or not the IDE to DE mapping should be performed. Choose one of the following from the pop-up menu: yes or no. |
LMI Operation Mode | Local Management Interface (LMI) operation mode. Can be one of:
|
Use this table to configure Port Real-Time Counters on a UFM-C card. (See Figure 14-3)

The parameters are described in Table 14-6.
| Parameter | Description |
|---|---|
Card Number | Identifies the slot the card is in. |
Port Number | Number of the logical port for that line. |
Rx Bytes | Traffic received in bytes. |
Tx Bytes | Traffic transmitted in bytes. |
Rx Frms | Traffic received in frames. |
Tx Frms | Traffic transmitted frames. |
Tx FECN Frms | Total number of frames transmitted with the FECN bit set. |
Tx BECN Frms | Total number of frames transmitted with the BECN bit set. |
# DE Frms Dropped | Total number of DE frames dropped due to queue threshold met. |
Rx Frm CRC Errs | Total number of frames received with CRC errors. |
Frms with Illegal Fmts | Total number of frames received with incorrect illegal formats. |
Rx Alignment Err Frms | Total number of frames dropped with non-bytes aligned payload. |
Rx Illegal Len Frms | Total number of frames received with illegal length. |
# DMA Overruns | The total number of DMA overruns. |
Unknown DLCIs | Total number of received frames with invalid/unknown DLCI dropped. |
CLLM Tx Bytes | Total number of CLLM bytes transmitted. |
CLLM Rx Bytes | Total number of CLLM frames received. |
CLLM Tx Frms | Total number of CLLM frames transmitted. |
CLLM Rx Frms | Total number of CLLM frames received. |
CLLM Failures | Total number of CLLM failures. |
LMI Fail Frames | Total number of LMI failure frames. |
LMI Fail Bytes | Total number of LMI failure bytes. |
![]() |
Note This is not a configurable dialog. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()