|
|
The HDM front card in an IGX node is a programmable communications processor that can support one to four high speed, synchronous data channels. It operates at speeds from 1.2 Kbps up to 1344 Kbps on all four ports while performing link error monitoring.
To display the Card Configuration dialog for this device (using the rear or front view), right-click on the card to display the card "Configure" pop-up menu, then select Configure.
Use this dialog to display HDM card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 9-1.
| Parameter | Description |
|---|---|
Slot No | Identifies the slot the card is in. |
Card Status | Status of the card. Examples are:
|
FrontCard Type | Identifies the type of front card. In this case, it is an NTM. |
Front Card Serial# | Serial number on the front card. |
FrontCard Revision | Model, hardware revision, and firmware revision of the front card. |
Card Y-RedStatus | Card Y-Redundancy status. The values can be one of: primary, secondary, null. |
AssocCard for Y-red | Associated slot for this card's Y-Redundancy. If the Card Y-RedStatus is primary, the secondary card index displays in this field. If the Card Y-RedStatus is secondary, the primary slot index displays in this field. If Card Y-RedStatus is null, a zero (0) appears in this field. |
Processor BOOTId | Boot ID of the processor card. If the card is not a processor card, this field is blank. |
No. Ports (Front Card) | Number of ports on the front card. |
![]() |
Note This is not a configurable dialog. |
Use this dialog to view back card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 9-2.
| Parameter | Description |
|---|---|
Slot No. | Number that identifies the slot the card is installed in. |
Card Status | Status of the card. Examples are:
|
BackCard Type | Back card type. |
BackCard Serial # | Serial number on the card. |
BackCard Revision | Model number and hardware revision of the back card. |
No. Ports (Backcard) | Number of ports on the back of the card. |
![]() |
Note The parameters in this dialog cannot be configured. |
To open the Port Configuration dialog, right-click on a port (rear view) to display the "Configure" pop-up menu, then click Configure. The HDM Port Configuration dialog appears as in Figure 9-1.
The parameters are described in Table 9-3.
| Parameter | Description |
Card | Number that identifies the slot the card is in. |
Line | Number of the line. |
SerialPort Interface Type | Type of physical interface associated with the port. Can be one of: RS-232, RS-449, X21, V35, HSSI (High Speed Serial Interface). |
Oper Status | Operational status of the port. Can be up, down, other, or failed. |
SerialPort DCE/DTE | DCE/DTE type of the port. |
SerialPort Clock | Port clocking configuration. Choose one of the following from the pop-up menu: other, normal, split, looped. |
SerialPort Utilization | Port percentage utilization. Enter the appropriate value into the field. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Apr 17 12:05:17 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.