The ATM Line Module A (ALM/A) provides an ATM UNI port that allows devices such as routers or ATM switches to support VPCs and VCCs across the IGX node.
To display the Card Configuration dialog for this device (using the rear or front view), right-click on the card to display the card "Configure" pop-up menu, then select Configure.
Use this dialog to display ALM-A card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 5-1.
| Parameter | Description |
|---|---|
Slot No. | Identifies the slot the card is in. |
Card Status | Status of the card. Examples are:
|
FrontCard Type | Identifies the type of front card. In this case, it is an NTM. |
Front Card Serial# | Serial number on the front card. |
FrontCard Revision | Model, hardware revision, and firmware revision of the front card. |
Card Y-RedStatus | Card Y-Redundancy status. The values can be one of: primary, secondary, null. |
AssocCard for Y-red | Associated slot for this card's Y-Redundancy. If the Card Y-RedStatus is primary, the secondary card index displays in this field. If the Card Y-RedStatus is secondary, the primary slot index displays in this field. If Card Y-RedStatus is null, a zero (0) appears in this field. |
No. Ports (Front Card) | Number of ports on the front card. |
![]() |
Note The parameters in this dialog cannot be configured. |
Use this dialog to view backcard characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 5-2.
| Parameter | Description |
|---|---|
Slot No. | Number that identifies the slot the card is installed in. |
Card Status | Status of the card. Examples are:
|
Backcard Type | Back card type. |
Backcard Serial # | Serial number on the card. |
Backcard Revision | Model number and hardware revision of the back card. |
No. Ports (Backcard) | Number of ports on the back of the card. |
![]() |
Note The parameters in this dialog cannot be configured. |
To open the Port Configuration dialog, right-click on the port to display the "Configure" pop-up menu, then click Configure. From the Port Configuration dialog, use the Category pull-down menu to select one of the two ALM/A Port dialogs.
These dialogs are described in the subsections that follow.
To display and configure Ports on an ALM-A card, select IGX: Port Config from the Category menu. The parameters are described in Table 5-3.
| Parameter | Description |
|---|---|
Card number | Number that identifies the slot the card is in. |
Port Number | Port number of the logical port for that line. |
Line Number | Number of the line. |
Admin Status | Admin status of the port. Choose one from the pop-up menu:
|
Operational Status | Operational status of the port. Can be active, failed, inactive, looped, or unknown. |
Port Speed | Baud rate of the port. |
IDE to DE Map | Flag indicating whether or not the IDE to DE mapping should be performed. Choose one of the following from the pop-up menu: yes or no. |
LMI Operation Mode | Local Management Interface (LMI) operation mode. Choose one from the pop-up menu:
|
To display and configure Port real time Counters on an ALM/A card, select IGX: Port Real-Time Counters from the Category>Ports menu. The parameters are described in Table 5-4.
| Parameter | Description |
|---|---|
Card Number | Number that identifies the slot the card is in. |
Port Number | Port number of the logical port for that line. |
Rx Bytes | Traffic received in bytes. |
Tx Bytes | Traffic transmitted in bytes. |
Rx Frms | Traffic received in frames. |
Tx Frms | Traffic transmitted frames. |
Tx FECN Frms | Total number of frames transmitted with the FECN bit set. |
Tx BECN Frms | Total number of frames transmitted with the BECN bit set. |
# DE Frms Dropped | Total number of DE frames dropped due to queue threshold met. |
Rx Frm CRC Errs | Total number of frames received with CRC errors. |
Frms With Illegal Fmts | Total number of frames received with incorrect illegal formats. |
Rx Alignment Err Frms | Total number of frames dropped with non-bytes aligned payload. |
Rx Illegal Len Frms | Total number of frames received with illegal length. |
# DMA Overruns | Total number of DMA overruns. |
Unknown DLCIs | Total number of received frames with invalid/unknown DLCI dropped. |
CLLM Tx Bytes | Total number of CLLM bytes transmitted. |
CLLM Rx Bytes | Total number of CLLM frames received. |
CLLM Tx Frms | Total number of CLLM frames transmitted. |
CLLM Rx Frms | Total number of CLLM frames received. |
CLLM Failures | Total number of CLLM failures. |
LMI Fail Frames | Total number of LMI failure frames. |
LMI Fail Bytes | Total number of LMI failure bytes. |
![]() |
Note This is not a configurable dialog. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Apr 17 12:02:55 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.