Select the card (on both the rear or front view) to display the Card Configuration dialog by doing one of the following:
Use the Card Configuration dialog to view BNI-155 card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 7-1.
| Parameter | Description |
|---|---|
Slot No. | Number that identifies the slot the card is installed in. |
Card Status | Status of the card. Examples are:
|
BackCard Type | Back card type. |
BackCard Serial # | Serial number on the card. |
BackCard Revision | Model number and hardware revision of the back card. |
No. Ports (Backcard) | Number of ports on the back of the card. |
Select the Line (on the rear view) to display the Intf Configuration dialog by doing one of the following:
The BNI-155 Intf menu item provides one of more of the following configuration dialogs. The dialogs provided differ according to the interface:
These dialogs are described in the subsections that follow.
Use the Physical Line Configuration dialog to view physical line configuration features on a BNI-155. The Physical Line Configuration dialog parameters are described in Table 7-1.
| Parameter | Description |
Card | Number that identifies the slot the card is in. |
Line | Number of the line. |
Interface Type | Line Interface type. |
Vtrk | Virtual trunk number. |
| Parameter | Description |
Service | Type of service for the line. Choose one from the popup menu:
|
Admin Status | Administrative status of the line. Choose one from the popup menu:
|
Oper Status | Operational status of the line. Can be one of the following:
|
Use the ATM Trunk Configuration dialog to view ATM trunk configuration features on a BNI-155. The ATM Trunk Configuration dialog parameters are described in Table 7-3.
| Parameter | Description |
vtrk | Identifies the slot the trunk is in. |
Trunk Status | Status of the trunk. Can be one of: major, minor, clear, down, deact (deactivated). |
Disable Trunk Alarm | Allows you to disable the trunk alarm. Choose one of the following from the pop-up menu: enable or disable. The default is enable. |
Xmit Rate (cps) | Trunk transmission rate in unit of cells per second. |
Xmit Capacity (cps) | Transmit capacity of this trunk in cells per second. |
Xmit Load (cps) | Transmit load of this trunk in cells per second. |
Rcv Rate (1000 pkts/sec) | Receive rate in 1000 packets per second. Enter a value in the field. |
Rcv Capacity (cps) | Receive capacity in cells per second. |
Receive Load (cps) | Receive load in cells per second. |
Use the More ATM Trunk Configuration dialog to view more ATM trunk configuration features on a BNI-155. The More ATM Trunk Configuration dialog parameters are described in Table 7-3.
| Parameter | Description |
vtrk | Number that identifies the slot the trunk is in. |
Trunk Type | Status of the trunk. Can be one of: major, minor, clear, down, deact (deactivated). |
VPI Used | Virtual path identifier address for trunks using CAM or SAM. Enter a value in the field. |
Chans Reserved | Number of channels reserved for this trunk. Enter a value in the field. |
Traffic Class | Integer containing bits representing the traffic classes of this trunk. Enter one of the following into the field:
|
| Parameter | Description |
Other end Node Type | Type of node or shelf at the other side of this trunk. Can be one of:
|
Other end Node Name | Name of the node at the other side of this trunk. |
Other end IfIndex | Index for the other end point. |
Pass Synch? | Indicates whether or not the trunk is allowed to pass synchronization signals from a clock source to another node. Choose yes or no from the pop-up menu. |
State Reserve (cps) | Bandwidth reserved for statistical variations in cells per second. Enter a value in the field. The default is 1000. |
Loop Rcv Clock to Tx | Indicates whether or not to loop the clock to the transmit clock. Choose one of the following from the pop-up menu: yes or no. |
atmTrkDerouteDelayTimer | Deroute delay timer of the trunk in unit of second. The default value is 0. |
atmTrkGtwyChCount | Gateway Channel count. This cannot exceed the total number channels per port. |
Physical Link | Link type. Choose one of the following from the pop-up menu: satellite or terrestrial. The default is terrestrial. You cannot change this value after adding the trunk. |
Use the ATM Trunk Real Time Counters dialog to view ATM trunk Real Time counters on a BNI-155. The ATM Trunk Real Time Counters dialog parameters are described in Table 7-4.
| Parameter | Description |
Vtrk | Identifies the slot the trunk is in. |
cells to line | Total cells transmitted on the line. |
cells from port | Total cells received from the port. |
Voice cell drops | Number of transmitted ATM voice cell dropped. This statistics is not applicable to ATM Virtual Trunks, 0 is returned for ATM Virtual trunks. |
Ts cell drops | Number of transmitted time-stamped ATM cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. |
| Parameter | Description |
NTS cell drops | Number of transmitted non time-stamped ATM cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. |
Hi Pri cell drops | Number of transmitted high priority ATM cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. |
BurstyA cell drops | Number of transmitted bursty data A cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. |
BurstyB cell drops | Number of transmitted bursty data B cell dropped. This statistics is not applicable to ATM Virtual Trunks. 0 is returned for ATM Virtual trunks. |
CBR cell drops | Number of constant bit rate transmitted cells dropped. 0 is returned for ATM Virtual trunks. |
VBR cell drops | Number of variable bit rate transmitted cells dropped. 0 is returned for ATM Virtual trunks. |
ABR cell drops | Number of available bit rate transmitted cells dropped. 0 is returned for ATM Virtual trunks. |
Use the BPX:Line Config (DS3 Interface) dialog to view DS3 line configuration counters on a BNI-155. TheBPX:Line Config (DS3 Interface) dialog parameters are described in Table 7-5.
| Parameter | Description |
Card | Number that identifies the slot the card is in. |
Line | Number of the line. |
| Parameter | Description |
Line Alarm Status Information | Information on the status of the line alarm. Can be one of:
|
Line Coding | Type of ZCS line coding used on this line. Can be one of the following:
|
Clock Source | Transmit clock source. Can be one of: loopTiming, localTiming, throughTiming. |
Line Local Loopback | The current local loopback status. Choose enable or disable from the popup menu. |
Line Remote Loopback | The line remote loopback. Choose enable or disable from the popup menu. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Jun 7 20:05:14 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.