The Nodal Processor Module (NPM) is a 68040 microprocessor-based system controller that runs the software for controlling the IGX switch. The NPM communicates with the other system cards over the control bus. The NPM performs the following major functions:

The NPM communicates with all other nodes through a trunk that uses a reserved queue on the trunk. The NPM communication link with other nodes carries information about new connections, topology changes, and rerouting.

Selecting the Card and Displaying Card Parameters

Select the card (on both the rear or front view) to display the the Card Configuration dialog by doing one of the following:

Front Card Configuration Dialog

Figure 17-1 shows the parameters for an NPM front card. Use this dialog to display NPM card characteristics, hardware, firmware, and status information.


Figure 17-1: NPM Card Configuration Dialog

The Card Configuration dialog parameters are described in .


Table 17-1: Card Configuration Dialog Parameters---Front View

Parameter

Description

Slot No

Identifies the slot the card is in.

Card Status

Status of the card. Examples are:

  • Active---Card in use. No failure.

  • Standby---Card idle. No failures.

  • Failed---Card failed.

  • Down---Card downed.

  • Mismatch---Mismatch between front card and back card.

  • Missing---An active card has been removed.

FrontCard Type

Identifies the type of front card. In this case, it is an NTM.

Front Card Serial#

Serial number on the front card.

FrontCard Revision

Model, hardware revision, and firmware revision of the front card.

Card Y-RedStatus

Card Y-Redundancy status. The values can be one of: primary, secondary, null.

AssocCard for Y-red

Associated slot for this card's Y-Redundancy. If the Card Y-RedStatus is primary, the secondary card index displays in this field. If the Card Y-RedStatus is secondary, the primary slot index displays in this field. If Card Y-RedStatus is null, a zero (0) appears in this field.

Processor BOOTId

Boot ID of the processor card. If the card is not a processor card, this field is blank.

Processor RAM Size(Mbytes)

RAM size of the processor card in megabytes. If the card is not a processor card, na appears in this field.

Processor FEPROM Size

FEPROM size of the processor card. Can be one of: meg4, meg3, meg2, unknown, meg8. If the card is not a processor card, "na" appears in this field.

Processor BRAM Size(Mbytes)

BRAM size of the processor card in megabytes. If the card is not a processor card, na appears in this field.

No. Ports(Front Card)

Number of ports on the front card.

Slot No.

Identifies the slot the card is in.


Note This is not a configurable dialog.

Back Card Configuration Dialog

Use this dialog to view back card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 17-2.


Table 17-2:
Parameter Description

Slot No.

Number that identifies the slot the card is installed in.

Card Status

Status of the card. Examples are:

  • Active---Card in use. No failure.

  • Standby---Card idle. No failures.

  • Failed---Card failed.

  • Down---Card downed.

  • Mismatch---Mismatch between front card and back card.

  • Missing---An active card has been removed.

BackCard Type

Back card type.

BackCard Serial #

Serial number on the card.

BackCard Revision

Model number and hardware revision of the back card.

No. Ports (Backcard)

Number of ports on the back of the card.

Card Configuration Dialog Parameters---Rear View

Note The parameters in this dialog cannot be configured.