The alarm relays are controlled by system software through Control Bus commands. The ARM interface with the Control Bus allows the card to receive alarm signals from the NPM and to send status signals back to the NPM. The firmware on the ARM decodes the alarms. The ARM does not connect to the Cellbus because it does not packetize user-data.

Selecting the Card and Displaying Card Parameters

Select the card (on both the rear or front view) to display the the Card Configuration dialog by doing one of the following:

Front Card Configuration Dialog

Use this dialog to display ARM card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 16-1.


Table 16-1: Card Configuration Dialog Parameters---Front View

Parameter

Description

Slot No

Identifies the slot the card is in.

Card Status

Status of the card. Examples are:

  • Active---Card in use. No failure.

  • Standby---Card idle. No failures.

  • Failed---Card failed.

  • Down---Card downed.

  • Mismatch---Mismatch between front card and back card.

  • Missing---An active card has been removed.

FrontCard Type

Identifies the type of front card. In this case, it is an NTM.

Front Card Serial#

Serial number on the front card.

FrontCard Revision

Model, hardware revision, and firmware revision of the front card.

Card Y-RedStatus

Card Y-Redundancy status. The values can be one of: primary, secondary, null.

AssocCard for Y-red

Associated slot for this card's Y-Redundancy. If the Card Y-RedStatus is primary, the secondary card index displays in this field. If the Card Y-RedStatus is secondary, the primary slot index displays in this field. If Card Y-RedStatus is null, a zero (0) appears in this field.

Processor BOOTId

Boot ID of the processor card. If the card is not a processor card, this field is blank.

Processor RAM Size(Mbytes)

RAM size of the processor card in megabytes. If the card is not a processor card, na appears in this field.

Processor FEPROM Size

FEPROM size of the processor card. Can be one of: meg4, meg3, meg2, unknown, meg8. If the card is not a processor card, "na" appears in this field.

Processor BRAM Size(Mbytes)

BRAM size of the processor card in megabytes. If the card is not a processor card, na appears in this field.

No. Ports(Front Card)

Number of ports on the front card.

Slot No.

Identifies the slot the card is in.


Note This is not a configurable dialog.

Back Card Configuration Dialog

Use this dialog to view back card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 16-2.


Table 16-2:
Parameter Description

Slot No.

Number that identifies the slot the card is installed in.

Card Status

Status of the card. Examples are:

  • Active---Card in use. No failure.

  • Standby---Card idle. No failures.

  • Failed---Card failed.

  • Down---Card downed.

  • Mismatch---Mismatch between front card and back card.

  • Missing---An active card has been removed.

BackCard Type

Back card type.

BackCard Serial #

Serial number on the card.

BackCard Revision

Model number and hardware revision of the back card.

No. Ports (Backcard)

Number of ports on the back of the card.

Card Configuration Dialog Parameters---Rear View