FRSM-HS1/B module sits in any of the MGX 8220 Service Module slots. The FRSM HS1/B is a high Speed frame relay service module. It provides two 52 Mbps HSSI lines and a peak throughput of 104 Mbps.
This chapter describes dialogs that show configuration information for:
You can select the FRSM card to display card configuration dialogs by doing one of the following:
The FRSM HS1/B Card Category menu provides access to the following dialogs described in the sections below:
Use the Card Configuration dialog to view FRSM HS1/BFRSM HS1/B card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Figure 10-1.
The parameters are described in Table 10-1
| Parameter | Description |
|---|---|
Slot Number | Number of the current slot the card is installed in. |
Card Type | Current card type. In this case, it is an FRSM HS1/B. |
Card State | Front card status. Can be one of the following:
|
Front Card Description | Description of the front card. |
Front Card Serial No | Serial number of the front card. |
Card Hardware Revision | Current card hardware revision. |
Card Firmware Revision | Current card firmware revision. |
MIB Version Number | MIB version number updated when any part of the MIB changes. |
Card Reset Reason | Reason for the last card reset. Can be one of the following:
|
Line Module Type | Current line module number. |
Line Module State | Current back card state. Can be notPresent, Present, invalid. |
Line Module Description | Description of the current back card. |
Line Module Serial Number | Serial number of the current back card. |
Line Module Hardware Revision | Hardware revision of the current back card. |
Line Module Firmware Revision | Firmware revision of the current back card. |
Use the Service Module Features dialog to view service module features for this card. (See Figure Figure 10-2

The parameters are described in Table 10-2
| Parameter | Description |
|---|---|
Card Supports Foresight? | BRAM parameter indicating whether this card will support ForeSight. Can be rateControlEnabled or rateControlDisabled. |
Use the FR Port Realtime Counters dialog to configure FR port Realtime counters on a FRSM HS1/B card. (See Figure 10-3.)

The FR Port Realtime Counters dialog parameters are described in Table 10-3.
| Parameter | Description |
|---|---|
Port Num | Port number. |
Rcv Port Frames | Total number of receive port frames. |
Rcv Port Bytes | Total number of receive port bytes. |
Rcv Port Frames with DE | Total number of frames received in the Ingress direction. |
Rcv Port FECNs | Total number of frames with forward explicit congestion notification (FECN) bit set in the Ingress direction. |
Rcv Port BECNs | Total number of frames with backward explicit congestion notification (BECN) bit set in the Ingress direction. |
Rcv CRC ErrFrames | Total number of frames discarded in Ingress due to cycle redundancy check (CRC) error. |
Rcv Frames DiscAlignmentErr | Total number of frames discarded in Ingress due to alignment error. |
Rcv Frames DisIllLen | Total number of frames discarded in Ingress due to alignment error. |
Rcv Frames DiscIllLen | Total number of frames discarded in Ingress due to illegal length. |
Rcv Frames Illegal Header | Total number of frames discarded in Ingress due to illegal header. |
Rcv Frames Abort | Total number of received frames aborted. |
Rcv Frames Unknown DLCI | Total number of frames received with an unknown DLCI. |
Rcv Last UnKnown DLCI | Last unknown DLCI received. |
Rcv Frames Tagged FECN | Total number of frames received that were tagged with forward explicit congestion notification (FECN) bit. |
Rcv FramesTaggedBECN | Number of frames received that were tagged with backward explicit congestion notification (BECN) bit. |
Rcv Frames Tagged DE | Total number of frames received that were tagged with discard eligible (DE) bit. |
Rcv Frames Disc Exceeded Threshold | Total number of frames discarded in Ingress due to exceeded discard eligible (DE) threshold. |
Rcv Kbps AIR | Received Average Information Rate (AIR) in Kbps. |
Rcv Buf Not Available | The total number of times the receiver is turned off. |
Xmt Port Frames | Total number of frames transmitted. |
Xmt Port Bytes | Total number of bytes transmitted. |
Xmt Port Frames FECN | Total number of frames transmitted with forward explicit congestion notification (FECN) bit already set. |
Xmt Port Frames BECN | Total number of frames transmitted with backward explicit congestion notification (BECN) bit already set. |
Xmt Port Disc ExceedQDepth | Total number of frames discarded in Egress due to exceeded queue depth. |
XmtPortBytesDiscXceedQDepth | The total number of bytes discarded in Egress due to exceeded queue depth. |
Xmt Port Frames During LMI Alarm | The total number of frames transmitted during Local Management Interface (LMI) logical port alarm. |
Xmt Port Bytes During LMI Alarm | The total number of bytes transmitted during LMI logical port alarm. |
Xmt Port Frames Abort | The total number of transmit frames aborted. |
Xmt Port Underrun | The total number of frames discarded due to overrun. |
Xmt Kbps AIR | Transmit Average Information Rate in Kbps. |
Xmt Buf Not Available | The total number of times the transmitter is turned off. |
Rcv Frames Discarded due to No Chan | The total number of frames received when no channel is set up. |
Rcv Status Inquiry | The total number of Status Inquiry messages received. |
Rcv Invalid Request | The total number of Invalid Request messages received. |
Rcv Uni Seq Mismatch | The number of times User-Network Interface (UNI) messages with sequence number mismatches were received. |
Xmt Status | The number of times Status Response messages were transmitted. |
Xmt Asynch Update | The number of times Asynchronous Status messages were transmitted. |
UNI Signalling Timeout | The number of times User-Network Interface (UNI) Status Requests were not received. |
Xmt Status Inquiry | The number of status inquiry messages transmitted. |
RCV Asynch Update | The number of times asynchronous status messages were received. |
Rcv NNI Seq Mismatch | The number of times Network-to-Network (NNI) messages with sequence number mismatches were received. |
Rcv NNI Signaling Timeout | The number of times Network-to-Network (NNI) status requests were not received. |
Rcv Frames CLLM | The total number of CLLM frames received. |
Rcv Bytes CLLM | The total number of CLLM bytes received. |
Xmt Frames CLLM | The total number of CLLM frames transmitted. |
Xmt Bytes CLLM | The total number of XMT CLLM bytes received. |
CLLM Failures | The number of times an expected CLLM message was not received. |
![]() |
Note The FR Port Realtime Counters dialog is not a configurable dialog. |
Use the LCN Partition Type dialog to configure LCN partition type on a FRSM HS1/B card. (See Figure 10-4.)

Choose one from the cardLcnPartitionType pulldown menu:
No Partition | Disables partitioning on the current card. |
controllerBased | Enables controller based resource type for the current card. This means the total number of LCNs available to each controller is fixed but no reservation on each port. |
portControllerBased | Enables card specific resource partitioning on the current card. This means that a certain number of LCNs available on each port for each controller is reserved as specified in the port resource. |
![]() |
Note The dialog must be configured before adding any connections. Once a connection is added, this dialog cannot be changed until all of the connections are deleted. |
To modify LCN partition type, make the changes you want and click Modify.
Use the Ports dialog to configure X.21/V.35 Ports on a FRSM HSI/B card as shown in Figure 10-5.

The Ports dialog parameters are described in Table 10-4.
Use the Channels dialog to configure Channels on a FRSM HS1/B card as shown in Figure 10-6. The Channels dialog parameters are described in Table 10-5.

There are four ways to select the line (from either the front or rear view of the card) to display the appropriate line configuration dialog:
To display the configuration parameters for an X21 or V.35 line/port, select the Category popup menu at the top of the dialog. The categories of line configuration are:
Use the Physical Line Config (X.21/V.35) dialog to view and configure line information. (See Figure 10-7.)

The X.21/V.35 Line Config dialog parameters are described in Table 10-6.
| Parameter | Description |
|---|---|
Line Number | Line number. |
Line Enable | Disables, enables, or modifies a line. Can be one of the following:
The default is enable. |
Line Type | Line type. Can be dte or dce. The default is dce. |
Line/Port Rate (Kbps) | Line rate. |
Line Loopback Command | Line loopback command. Can be one of the following:
|
Line Send Code | Line send code. Can be one of the following:
|
Line Loopback Code Detection | Enables detection of line loopback codes. Can be codeDetectEnabled or codeDetectDisabled. The default is codeDetectDisabled. |
x21InvertClock | Each setting onfigures two options:
The possible settings are:
The default for X.21/HSSI is nonInvertedNotLooped. The default for V.35 is nonInvertedLooped. |
To modify the parameters, make the changes you want and click Modify.
Use the Physical Line Alarm Config (X.21/V.35) dialog to view and configureX.21/V.35 physical line alarm information. (See Figure 10-8.)
The Physical Line Alarm Config (X.21/V.35) dialog parameters are described in Table 10-7.
| Parameter | Description |
|---|---|
Alarm Line Num | Line number of the X21/HSSI interface. |
Lin Alarm State | Status of the line alarms. A value of zero indicates no alarms. |
Line EIA Status | Status of the X21/HSSI lines. |
Line Severity | Used to set up the severity of an LOS or clock mismatch alarm. When an LOS or clock mismatch occurs, the FRSM-HS1 sends an alarm with the appropriate status. Can be one of the following:
|
To modify the parameters, make the changes you want and click Modify.
There are four dialogs for FRSM HS1/B port configuration:
These dialogs are described in the sections that follow.
Use the Logical Port Config dialog to view and configure logical ports on an FRSM card. (See Figure 10-9.)

The Logical Port Config dialog parameters are described in Table 10-8.
| Parameter | Description |
|---|---|
Port No. | Logical port number. |
Line No. | Line number associated with the logical port. |
Port RowStatus | Port row status. Choose add, delete, or modify. |
Port Ds0 Config Bitmap | Bitmap of DS0s for a line, used to form this logical port. Bit 0 represents DS0-1. |
Port Ds0 Speed | Port DSO speed in cells per second. |
Port Flags | Number of flags transmitted between frame relay frames. |
EQueue Service Ratio | Number of times queue 1 is serviced for every time queue 2 is serviced. |
Port Speed (kbps) | Port DSO speed in kbps. |
Port Admin Status | Port administrative status. Choose one from the popup menu:
|
Port State | Logical port state. |
portSvcStatus | Port SVC status. |
portSvcShareLcn | Indicates whether or not the LCN and VPid address spaces are shared across all the ports. |
portSvcLcnLow | Beginning of the LCN range reserved for SVCs. |
portSvcLcnHigh | End of the LCN range reserved for SVCs. |
portSvcDlciLow | Beginning of the DLCI range reserved for SVCs. |
portSvcDlciHigh | End of the DLCI range reserved for SVCs. |
Port Type | Port type. Choose one from the pop-up menu:
|
Signalling Protocol Type | Signalling protocol type. Choose one from the pop-up menu:
|
Async Updates | Enables asynchronous status updates. Choose disable or enable. |
Link Integrity Timer (Secs) | Interval in seconds for NNI to do status polling. |
Poll Verification Timer (Secs) | Interval in seconds for UNI to expect status polling. |
Status Polling Counter | Number of UNI/NNI polling cycles. |
Error Threshold | UNI/NNI error threshold. |
Event Count | UNI/NNI events, always greater than the Error Threshold parameter. |
Enhance LMI | Indicates whether or not enhanced LMI is enabled on a logical port. Choose disable or enable. |
CLLM Enable | Enables or disables CLLM. Choose disable or enable. |
CLLM Xmt Status Timer (Milli Secs) | Interval in milliseconds for CLLM to send CLLM updates. |
Port Signalling State | Port signalling state. Bit 0 = 0 LMI okay or not enabled Bit 0 = 1 LMI failed Bit 1 = 0 CLLM okay or not enabled Bit 1 = 1 CLLM failed |
Port Oversubscribed | Indicates whether or not the port is oversubscribed. Can be one of: true or false. |
Port Ingress Percent Utilization | Percentage of utilization of the port in the Ingress direction. |
Port Egress Percent Utilization | Percentage of utilization of the port in the Egress direction. |
Use the FR Port RTCs dialog to view and configure port RealTime counters on a FRSM card. (See Figure 10-10.)
The FR Port RTCs dialog parameters are described in Table 10-9.
| Parameter | Description |
|---|---|
Port Num | Logical port number. |
Rcv Port Frames | Total number of frames received in the Ingress direction. |
Rcv Port Bytes | Total number of bytes received in the Ingress direction. |
Rcv Port Frames with DE | Total number of frames with DE bit set in the Ingress direction. |
Rcv Port FECNs | Total number of frames with FCNS bit set in the Ingress direction. |
Rcv Port BECNs | Total number of frames with BECN bit set in the Ingress direction. |
Rcv CRC ErrFrames | Total number of frames discarded in Ingress due to CRC error. |
Rcv Frames DiscAlignmentErr | Total number of frames discarded in Ingress due to alignment error. |
RcvFrames DiscIllLen | Total number of frames discarded in Ingress due to illegal length. |
Rcv Frames IllegalHeader | Total number of frames discarded in Ingress due to illegal header. |
Rcv Frames Abort | Total number of received frames aborted. |
Rcv Frames Unkn DLCI | Total number of frames received with an unknown DLCI. |
Rcv Last Unkn DLCI | Last unknown DLCI received. |
Rcv Frames Tagged FECN | Total number of frames received that were tagged with FECN bit. |
Rcv Frames Tagged BECN | Total number of frames received that were tagged with BECN bit. |
Rcv Frames Tagged DE | Total number of frames received that were tagged with DE bit. |
Rcv Frames Disc Exceeded Threshold | Total number of frames discarded in Ingress due to exceeded DE threshold. |
Rcv Kbps AIR | Received Average Information Rate in Kbps. |
Rcv Buf Not Available | Total number of times the receiver is turned off. |
Xmt Port Frames | Total number of frames transmitted. |
Xmt Port Bytes | Total number of bytes transmitted. |
Xmt Port Frames FECN | Total number of frames transmitted with FECN bit already set. |
Xmt Port Frames BECN | Total number of frames transmitted with BECN bit already set. |
Xmt Port Disc. Exceed Q Depth | Total number of bytes discarded in Egress due to exceeded queue depth. |
Xmt PortBytesDiscXceedQDepth | Total number of frames discarded in Egress due to exceeded queue depth. |
Xmt Port Frames During LMI Alarm | Total number of frames transmitted during LMI logical port alarm. |
Xmt Port Bytes During LMI Alarm | Total number of bytes transmitted during LMI logical port alarm. |
Xmt Frames Abort | Total number of transmit frames aborted. |
Xmt Frames Underrun | Total number of frames discarded due to overrun. |
Xmt Kbps AIR | Transmit Average Information Rate in Kbps. |
Xmt Buf Not Available | Total number of times the transmitter is turned off. |
Rcv Frames Discarded due to No Chan | Total number of frames received when no channel is set up. |
Rcv Status Inquiry | Total number of Status Inquiry messages received. |
Rcv Invalid Request | Total number of Invalid Request messages received. |
Rcv UNI Seq. Mismatch | Number of times UNI messages with sequence number mismatches were received. |
Xmt Status | Number of times Status Response messages were transmitted. |
Xmt Async Update | Number of times Asynchronous Status messages were transmitted. |
UNI Signalling Timeout | Number of times UNI Status Requests were not received. |
XMT Status Inquiry | Number of Status Inquiry messages transmitted. |
Rcv Async Update | Number of times Asynchronous Status messages were received. |
Rcv NNI Seq. Mismatch | Number of times NNI messages with sequence number mismatches were received. |
Rcv NNI Signalling Timeout | Number of times NNI Status requests were not received. |
Use the FR Port RTCs (CLLM) dialog to view and configure CLLM port RealTime counters on a FRSM card. (See Figure 10-11.)

The FR Port RTCs (CLLM) dialog parameters are described in Table 10-10.
| Parameter | Description |
|---|---|
Rcv Frames CLLM | Number of CLLM frames received. |
Rcv Bytes CLLM | Number of CLLM bytes received. |
Xmt Frames CLLM | Number of CLLM frames transmitted. |
Xmt Bytes CLLM | Number of CLLM bytes transmitted. |
CLLM Failures | Number of times an expected CLLM message was not received. |
Use the FR Port Resource Partition dialog to view and configure port resource partitions on a FRSM card. (See Figure 10-12.)
The FR Port Resource Partition dialog parameters are described in Table 10-11.
| Parameter | Description | ||
|---|---|---|---|
frResPartPortNum | Logical port number.
| ||
frResPartCtrlrNum | Index number for the controller using this port. Can be one of the following:
| ||
frResPartRowStatus | Used to add, delete or modify the partition. | ||
frResPartDlciLow | Represents low end of reserved DLCI. | ||
frResPartDlciHigh | Represents high end of reserved DLCI. | ||
frResPartIngrPctBw | Percentage of total ingress bandwidth reserved. | ||
frResPartEgrPctBw | Percentage of total egress bandwidth reserved. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()