Configuring FRSM-HS1 Cards

The FRSM-HS1 module sits in any of the MGX 8220 Service Module slots. The FRSM-HS1 is a high-speed Frame Relay service module. It provides 252 Mbps HSSI lines and a peak throughput of 104 Mbps.

Selecting the Card and Displaying Card Parameters

Select the FRSM card to display FRSM card configuration dialogs by doing one of the following:

The FRSM-HS2 Card Category menu contains the following items:

These dialogs are described in the sections that follow.

FRSM-HS1 Port Card Configuration Dialog

Use this dialog to view FRSM-HS1 card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 9-1.


Table 9-1: Card Configuration Dialog Parameters
Parameter Description

Slot Number

Number of the current slot the card is installed in.

Card Type

Current card type. In this case, it is an FRSM.

Card State

Front card status. Can be

  • nocard

  • standby

  • active

  • failed

  • selfTest

  • heldInReset

  • boot

  • mismatch

  • unknown

  • coreCardMisMatch

  • blocked

  • reserved

Front Card Description

Description of the front card.

Front Card Serial No

Serial number of the front card.

Card Hardware Revision

Current card hardware revision.

Card Firmware Revision

Current card firmware revision.

MIB Version Number

MIB version number updated when any part of the MIB changes.

Card Reset Reason

Reason for the last card reset. Can be Powerup, parityError, watchDog, resource, clrAll, missingTask.

Line Module Type

Current line module number.

Line Module State

Current back card state. Can be notPresent, Present, invalid.

Line Module Description

Description of the current back card.

Line Module Serial Number

Serial number of the current back card.

Line Module Hardware Revision

Hardware revision of the current back card

Line Module Firmware Revision

Firmware revision of the current back card.


Note This is not a configurable dialog.

FRSM-HS1 Service Module Features

Use this dialog to view service module features for the FRSM-HS1 card. (See Figure 9-1.)


Figure 9-1: FRSM-HS1 Service Module Features Dialog


The parameters are described in Table 9-2.


Table 9-2: FRSM-HS1 Service Module Features Dialog Parameters
Parameter Description

Channelized Card?

Indicates whether or not this card is channelized. Can be channelized or nonChannelized.

Card Supports ForeSight?

Indicates whether or not this card supports ForeSight. Can be rateControlEnabled or rateControlDisabled.

FR Port RealTime Counters

Use this table to configure FR Port RealTime Counters on an FRSM-HS1 card. (See Figure 9-2.)


Figure 9-2: FR Port RealTime Counters Table


The FR Port RealTime Counters table parameters are described in Table 9-3.


Table 9-3: FR Port RealTime Counters Dialog Parameters
Parameter Description

Port Num

Port number.

Rcv Port Frames

Total number of receive port frames.

Rcv Port Bytes

Total number of receive port bytes.

Rcv Port Frames with DE

Total number of frames received in the Ingress direction.

Rcv Port FECNs

Total number of frames with FCNS bit set in the Ingress direction.

Rcv Port BECNs

Total number of frames with BECN bit set in the Ingress direction.

Rcv CRC ErrFrames

Total number of frames discarded in Ingress due to CRC error.

Rcv Frames DiscAlignmentErr

Total number of frames discarded in Ingress due to alignment error.

Rcv Frames DisIllLen

Total number of frames discarded in Ingress due to alignment error.

Rcv Frames DiscIllLen

Total number of frames discarded in Ingress due to illegal length.

Rcv Frames Illegal Header

Total number of frames discarded in Ingress due to illegal header.

Rcv Frames Abort

Total number of received frames aborted.

Rcv Frames Unknown DLCI

Total number of frames received with an unknown DLCI.

Rcv Last UnKnown DLCI

Last unknown DLCI received.

Rcv Frames Tagged FECN

The total number of frames received that were tagged with FECN bit.

Rcv FramesTaggedBECN

Total number of frames received that were tagged with BECN bit.

Rcv Frames Tagged DE

Total number of frames received that were tagged with DE bit.

Rcv Frames Disc Exceeded Threshold

Total number of frames discarded in Ingress due to exceeded DE threshold.

Rcv Kbps AIR

Received Average Information Rate in Kbps.

Rcv Buf Not Available

Total number of times the receiver is turned off.

Xmt Port Frames

Total number of frames transmitted.

Xmt Port Bytes

Total number of bytes transmitted.

Xmt Port Frames FECN

Total number of frames transmitted with FECN bit already set.

Xmt Port Frames BECN

Total number of frames transmitted with BECN bit already set.

Xmt Port Disc ExceedQDepth

Total number of frames discarded in Egress due to exceeded queue depth.

XmtPortBytesDiscXceedQDepth

Total number of bytes discarded in Egress due to exceeded queue depth.

Xmt Port Frames During LMI Alarm

Total number of frames transmitted during LMI logical port alarm.

Xmt Port Bytes During LMI Alarm

Total number of bytes transmitted during LMI logical port alarm.

Xmt Port Frames Abort

Total number of transmit frames aborted.

Xmt Port Underrun

Total number of frames discarded due to overrun.

Xmt Kbps AIR

Transmit Average Information Rate in Kbps.

Xmt Buf Not Available

Total number of times the transmitter is turned off.

Rcv Frames Discarded due to No Chan

Total number of frames received when no channel is set up.

Rcv Status Inquiry

Total number of Status Inquiry messages received.

Rcv Invalid Request

Total number of Invalid Request messages received.

Rcv Uni Seq Mismatch

Number of times UNI messages with sequence number mismatches were received.

Xmt Status

Number of times Status Response messages were transmitted.

Xmt Asynch Update

Number of times Asynchronous Status messages were transmitted.

UNI Signalling Timeout

Number of times UNI Status Requests were not received.

Xmt Status Inquiry

Number of Status Inquiry messages transmitted.

RCV Asynch Update

Number of times Asynchronous Status messages were received.

Rcv NNI Seq Mismatch

Number of times NNI messages with sequence number mismatches were received.

Rcv NNI Signaling Timeout

Number of times NNI Status requests were not received.

Rcv Frames CLLM

Total number of CLLM frames received.

Rcv Bytes CLLM

Total number of CLLM bytes received.

Xmt Frames CLLM

Total number of CLLM frames transmitted.

Xmt Bytes CLLM

Total number of XMT CLLM bytes received.

CLLM Failures

Number of times an expected CLLM message was not received.


Note This is not a configurable dialog.

Ports

Use this table to configure X21/HSSI Ports on an FRSM-HS1 card. (See Figure 9-3.)


Figure 9-3: FRSM-HS1 Ports Dialog


The Ports table parameters are described in Table 9-4.


Table 9-4: X21/HSSI Ports Dialog Parameters
Parameter Description

Port Num

Logical port number.

Port Line Number

Line number.

Port Row Status

Port row enabled status. Choose one from the pop-up menu:

  • del

  • mod

Port Flags Between Frames

Number of flags transmitted between two consecutive HDLC frames. The default is one flag.

Port Equeue Service Ratio

Number of times queue 1 is serviced for every time queue 2 is serviced.

Line/Port Rate (Kbps)

Configures the X21/HSSI line rate.

Port Admin

Up/down used to up and down the port. Default is the up state.

Port Type

Port type. Choose one from the pop-up menu:

  • Frame-relay

  • frFUNI

  • frame-forward

Channels

Use this table to configure channels on an FRSM-HS1 card. (See Figure 9-4.)


Figure 9-4: FRSM-HS1 Channels Dialog


The Channels dialog parameters are described in Table 9-5.

:
Table 9-5: Channels Dialog Parameters
Parameter Description

Channel Number

Virtual connection number.

Channel RowStatus

Channel status. Choose one from the pop-up menu:

  • del

  • mod

Channel Port Number

Specifies the port number.

Clear Channel Counters

Clears Channel Port Counters. Choose noaction or yes.

DLCI

DLCI number of the channel.

Egress Q Select

Selects one of two possible port queues. Can be highPriority or lowPriority.

Ingress Q Depth

Sets the maximum depth for queue before it starts dropping cells.

Ingress Q ECN Threshold

Sets the maximum depth for queue before it starts flow control.

Ingress Q DE Threshold

Sets the maximum depth for queue before they become discard eligible.

Egress Q Depth

Sets the maximum depth for queue before it starts dropping the cells.

Egress Q DE Threshold

Sets the maximum depth for queue before they become discard eligible.

Egress Q ECN Threshold

Sets the maximum depth for queue before it starts flow control.

Enable DE Tagging

Enables DE tagging in the Ingress direction only. Choose enable or disable from the pop-up menu. The default is disable.

Committed Information Rate (BPS)

Defines the Committed Information Rate in bits per second. The default is 2400. The maximum value for E1 is 2048000; the maximum value for T1 is 1536000. CIR has to be less than or equal to the port speed.

Burst Committed

Defines the Burst Committed. The default value is 5100. If CIR is not 0, BC cannot be 0. BC must be 0 if CIR is 0.

Burst Excess

Defines the Burst Excess. The default value is 5100. If CIR is not 0, BE cannot be 0.

Burst Size

Default is 100. IBS should be less than or equal to BC when CIR is greater than 0. IBS must be 0 when CIR is 0.

Enable ForeSight

Sets the ForeSight option. Choose enable or disable from the pop-up menu. The default is disable.

Quiescent Information Rate (CPS)

Defines Quiescent Information Rate for ForeSight in cells per second. The default is 10.

Minimum Information Rate (CPS)

Defines Minimum Information Rate for ForeSight in cells per second. The default is 10.

Peak Information Rate (CPS)

Defines Peak Information Rate for foreSight in cells per second. The default is 10.

Remote Lpbk State

Enables or disables the remote loopback for each channel. When you enable this option on a channel, all the cells coming from the network side are looped back toward the network and all the frames coming from the user side are dropped. Choose enable or disable from the pop-up menu. The default is disable.

Channel Test Type

Tests the continuity or delay of a connection, sending specific cell patterns toward the network. Choose one from the pop-up menu:

  • testcon

  • testdelay

  • notest (This is the default.)

Channel Test State

State of the test. Can be

  • passed

  • failed

  • inprogress

  • notinprogress

Round Trip Delay (Milli Secs)

Round trip delay in milliseconds. When chanTestType is testdelay, the result of the test can be read in chanRTDResult.

Channel Type

Sets the channel type. Choose one from the pop-up menu:

  • frNIW: Frame Relay Network Interworking

  • frSIW-transparent: Service Interworking without any SDU translation

  • frSIW-translate: Service Interworking with SDU translation

  • frFUNI: Frame Relay UNI

  • frForward:Frame Forwarding

Channel FECN Config

Sets FECN config mapEFCI, valid only for SIW. The FECN bits in Frame Relay are mapped to EFCI bit in the ATM cells. Choose mapEFCI or setEFCIzero from the pop-up menu.

Map CLP Bit

Sets the mapping of CLP bit. Choose one from the pop-up menu:

  • mapCLP: The DE bit is mapped to CLP bit in ATM cell.

  • setCLPzero: The DE bit is ignored and CLP bit is set to a constant value.

  • setCLPone: The DE bit is ignored and CLP bit is set to a constant value.

Map DE Bit

Sets the mapping of DE bit. Choose one from the pop-up menu:

  • mapDE: The CLP bit is mapped to DE bit in frame relay.

  • setDEzero: The CLP bit is ignored and DE bit is set to a constant value.

  • setDEone: The CLP bit is ignored and DE bit is set to a constant value.

  • ignoreCLP: Ignores CLP bit and DE bit remains as received.

Ingress Percent Util

Channel Ingress utilized percentage.

Egress Percent Util

Channel Egress utilized percentage.

Egress CIR

Channel Egress CIR.

Override Oversubscription

Permits adding a new connection on a port even if it is oversubscribed. Choose disable or enable from the pop-up menu.

FR Conn Type

Channel connection type. Choose pvc or svc from the pop-up menu.

FR CDR Number

Key to correlate cell/frame counts, start/end record.


hometocprevnextglossaryfeedbacksearchhelp