The FRSM-HS1 module sits in any of the MGX 8220 Service Module slots. The FRSM-HS1 is a high-speed Frame Relay service module. It provides 252 Mbps HSSI lines and a peak throughput of 104 Mbps.
Select the FRSM card to display FRSM card configuration dialogs by doing one of the following:
The FRSM-HS2 Card Category menu contains the following items:
These dialogs are described in the sections that follow.
Use this dialog to view FRSM-HS1 card characteristics, hardware, firmware, and status information. The Card Configuration dialog parameters are described in Table 9-1.
| Parameter | Description |
|---|---|
Slot Number | Number of the current slot the card is installed in. |
Card Type | Current card type. In this case, it is an FRSM. |
Card State | Front card status. Can be
|
Front Card Description | Description of the front card. |
Front Card Serial No | Serial number of the front card. |
Card Hardware Revision | Current card hardware revision. |
Card Firmware Revision | Current card firmware revision. |
MIB Version Number | MIB version number updated when any part of the MIB changes. |
Card Reset Reason | Reason for the last card reset. Can be Powerup, parityError, watchDog, resource, clrAll, missingTask. |
Line Module Type | Current line module number. |
Line Module State | Current back card state. Can be notPresent, Present, invalid. |
Line Module Description | Description of the current back card. |
Line Module Serial Number | Serial number of the current back card. |
Line Module Hardware Revision | Hardware revision of the current back card |
Line Module Firmware Revision | Firmware revision of the current back card. |
![]() |
Note This is not a configurable dialog. |
Use this dialog to view service module features for the FRSM-HS1 card. (See Figure 9-1.)

The parameters are described in Table 9-2.
| Parameter | Description |
Channelized Card? | Indicates whether or not this card is channelized. Can be channelized or nonChannelized. |
Card Supports ForeSight? | Indicates whether or not this card supports ForeSight. Can be rateControlEnabled or rateControlDisabled. |
Use this table to configure FR Port RealTime Counters on an FRSM-HS1 card. (See Figure 9-2.)

The FR Port RealTime Counters table parameters are described in Table 9-3.
| Parameter | Description |
|---|---|
Port Num | Port number. |
Rcv Port Frames | Total number of receive port frames. |
Rcv Port Bytes | Total number of receive port bytes. |
Rcv Port Frames with DE | Total number of frames received in the Ingress direction. |
Rcv Port FECNs | Total number of frames with FCNS bit set in the Ingress direction. |
Rcv Port BECNs | Total number of frames with BECN bit set in the Ingress direction. |
Rcv CRC ErrFrames | Total number of frames discarded in Ingress due to CRC error. |
Rcv Frames DiscAlignmentErr | Total number of frames discarded in Ingress due to alignment error. |
Rcv Frames DisIllLen | Total number of frames discarded in Ingress due to alignment error. |
Rcv Frames DiscIllLen | Total number of frames discarded in Ingress due to illegal length. |
Rcv Frames Illegal Header | Total number of frames discarded in Ingress due to illegal header. |
Rcv Frames Abort | Total number of received frames aborted. |
Rcv Frames Unknown DLCI | Total number of frames received with an unknown DLCI. |
Rcv Last UnKnown DLCI | Last unknown DLCI received. |
Rcv Frames Tagged FECN | The total number of frames received that were tagged with FECN bit. |
Rcv FramesTaggedBECN | Total number of frames received that were tagged with BECN bit. |
Rcv Frames Tagged DE | Total number of frames received that were tagged with DE bit. |
Rcv Frames Disc Exceeded Threshold | Total number of frames discarded in Ingress due to exceeded DE threshold. |
Rcv Kbps AIR | Received Average Information Rate in Kbps. |
Rcv Buf Not Available | Total number of times the receiver is turned off. |
Xmt Port Frames | Total number of frames transmitted. |
Xmt Port Bytes | Total number of bytes transmitted. |
Xmt Port Frames FECN | Total number of frames transmitted with FECN bit already set. |
Xmt Port Frames BECN | Total number of frames transmitted with BECN bit already set. |
Xmt Port Disc ExceedQDepth | Total number of frames discarded in Egress due to exceeded queue depth. |
XmtPortBytesDiscXceedQDepth | Total number of bytes discarded in Egress due to exceeded queue depth. |
Xmt Port Frames During LMI Alarm | Total number of frames transmitted during LMI logical port alarm. |
Xmt Port Bytes During LMI Alarm | Total number of bytes transmitted during LMI logical port alarm. |
Xmt Port Frames Abort | Total number of transmit frames aborted. |
Xmt Port Underrun | Total number of frames discarded due to overrun. |
Xmt Kbps AIR | Transmit Average Information Rate in Kbps. |
Xmt Buf Not Available | Total number of times the transmitter is turned off. |
Rcv Frames Discarded due to No Chan | Total number of frames received when no channel is set up. |
Rcv Status Inquiry | Total number of Status Inquiry messages received. |
Rcv Invalid Request | Total number of Invalid Request messages received. |
Rcv Uni Seq Mismatch | Number of times UNI messages with sequence number mismatches were received. |
Xmt Status | Number of times Status Response messages were transmitted. |
Xmt Asynch Update | Number of times Asynchronous Status messages were transmitted. |
UNI Signalling Timeout | Number of times UNI Status Requests were not received. |
Xmt Status Inquiry | Number of Status Inquiry messages transmitted. |
RCV Asynch Update | Number of times Asynchronous Status messages were received. |
Rcv NNI Seq Mismatch | Number of times NNI messages with sequence number mismatches were received. |
Rcv NNI Signaling Timeout | Number of times NNI Status requests were not received. |
Rcv Frames CLLM | Total number of CLLM frames received. |
Rcv Bytes CLLM | Total number of CLLM bytes received. |
Xmt Frames CLLM | Total number of CLLM frames transmitted. |
Xmt Bytes CLLM | Total number of XMT CLLM bytes received. |
CLLM Failures | Number of times an expected CLLM message was not received. |
![]() |
Note This is not a configurable dialog. |
Use this table to configure X21/HSSI Ports on an FRSM-HS1 card. (See Figure 9-3.)

The Ports table parameters are described in Table 9-4.
| Parameter | Description |
|---|---|
Port Num | Logical port number. |
Port Line Number | Line number. |
Port Row Status | Port row enabled status. Choose one from the pop-up menu:
|
Port Flags Between Frames | Number of flags transmitted between two consecutive HDLC frames. The default is one flag. |
Port Equeue Service Ratio | Number of times queue 1 is serviced for every time queue 2 is serviced. |
Line/Port Rate (Kbps) | Configures the X21/HSSI line rate. |
Port Admin | Up/down used to up and down the port. Default is the up state. |
Port Type | Port type. Choose one from the pop-up menu:
|
Use this table to configure channels on an FRSM-HS1 card. (See Figure 9-4.)

The Channels dialog parameters are described in Table 9-5.
| Parameter | Description |
|---|---|
Channel Number | Virtual connection number. |
Channel RowStatus | Channel status. Choose one from the pop-up menu:
|
Channel Port Number | Specifies the port number. |
Clear Channel Counters | Clears Channel Port Counters. Choose noaction or yes. |
DLCI | DLCI number of the channel. |
Egress Q Select | Selects one of two possible port queues. Can be highPriority or lowPriority. |
Ingress Q Depth | Sets the maximum depth for queue before it starts dropping cells. |
Ingress Q ECN Threshold | Sets the maximum depth for queue before it starts flow control. |
Ingress Q DE Threshold | Sets the maximum depth for queue before they become discard eligible. |
Egress Q Depth | Sets the maximum depth for queue before it starts dropping the cells. |
Egress Q DE Threshold | Sets the maximum depth for queue before they become discard eligible. |
Egress Q ECN Threshold | Sets the maximum depth for queue before it starts flow control. |
Enable DE Tagging | Enables DE tagging in the Ingress direction only. Choose enable or disable from the pop-up menu. The default is disable. |
Committed Information Rate (BPS) | Defines the Committed Information Rate in bits per second. The default is 2400. The maximum value for E1 is 2048000; the maximum value for T1 is 1536000. CIR has to be less than or equal to the port speed. |
Burst Committed | Defines the Burst Committed. The default value is 5100. If CIR is not 0, BC cannot be 0. BC must be 0 if CIR is 0. |
Burst Excess | Defines the Burst Excess. The default value is 5100. If CIR is not 0, BE cannot be 0. |
Burst Size | Default is 100. IBS should be less than or equal to BC when CIR is greater than 0. IBS must be 0 when CIR is 0. |
Enable ForeSight | Sets the ForeSight option. Choose enable or disable from the pop-up menu. The default is disable. |
Quiescent Information Rate (CPS) | Defines Quiescent Information Rate for ForeSight in cells per second. The default is 10. |
Minimum Information Rate (CPS) | Defines Minimum Information Rate for ForeSight in cells per second. The default is 10. |
Peak Information Rate (CPS) | Defines Peak Information Rate for foreSight in cells per second. The default is 10. |
Remote Lpbk State | Enables or disables the remote loopback for each channel. When you enable this option on a channel, all the cells coming from the network side are looped back toward the network and all the frames coming from the user side are dropped. Choose enable or disable from the pop-up menu. The default is disable. |
Channel Test Type | Tests the continuity or delay of a connection, sending specific cell patterns toward the network. Choose one from the pop-up menu:
|
Channel Test State | State of the test. Can be
|
Round Trip Delay (Milli Secs) | Round trip delay in milliseconds. When chanTestType is testdelay, the result of the test can be read in chanRTDResult. |
Channel Type | Sets the channel type. Choose one from the pop-up menu:
|
Channel FECN Config | Sets FECN config mapEFCI, valid only for SIW. The FECN bits in Frame Relay are mapped to EFCI bit in the ATM cells. Choose mapEFCI or setEFCIzero from the pop-up menu. |
Map CLP Bit | Sets the mapping of CLP bit. Choose one from the pop-up menu:
|
Map DE Bit | Sets the mapping of DE bit. Choose one from the pop-up menu:
|
Ingress Percent Util | Channel Ingress utilized percentage. |
Egress Percent Util | Channel Egress utilized percentage. |
Egress CIR | Channel Egress CIR. |
Override Oversubscription | Permits adding a new connection on a port even if it is oversubscribed. Choose disable or enable from the pop-up menu. |
FR Conn Type | Channel connection type. Choose pvc or svc from the pop-up menu. |
FR CDR Number | Key to correlate cell/frame counts, start/end record. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Feb 4 10:58:36 PST 2000