Technical Specifications

Technical Specifications

This appendix provides the technical specifications relevant to the Service Expansion Shelf, its processor and service modules, and the applications and services which it provides. It contains the following sections:

SES Enclosure, Power, and Performance Specifications

This section describes the physical characteristics and system power requirements for the
MGX 8850 switch. The "SES Processor Switching Module Specifications" section lists the dimensions, weight, and power consumption for each card. The appendix titled "Cabling Specifications" lists the AC power plugs for domestic and international use.


Table A-1: Enclosure and Electrical Characteristics
Item Value

Card Slot Capacity

Supports combinations of full and single-height service modules.
Two double-height slots reserved for SES-PXMs.
Up to 10 single-height slots for service modules or
Up to 5 double-height slots for service modules.

Enclosure Size,
AC-powered system:



DC-powered system:


8 Rack Units high
Height: 14.00 inches (x cm).
Width: 17.72 ins (x cm).
Depth: 23.5 ins (x cm) (excluding cable management)


7 Rack Units high
Height: 12.25 inches (x cm).
Width: 17.72 inches (x cm).
Depth: 23.5 inches (x cm) (excluding cable management)

Shipping Weight for
Populated Enclosure:

Approximately 150 lbs.

Clearance Requirement:

Minimum 30 inches front and rear; nominal 12-inch side clearance.

Power Input Voltage:

AC system: Normal operating range is 100-240 VAC, 47 to 63 Hz.
The maximum voltage range is 90-264 VAC.
DC system: -42 to -56 VDC.

Each AC supply can provide up to 1200 watts @ 48 VDC.

Current Requirements,
AC System

Configuration-dependent: use Network Design Tool for exact requirements.

Current Requirements,
DC System

Configuration-dependent: use Network Design Tool for exact requirements. For general planning purposes: 25 Amps at nominal -48 VDC; 29 Amps at
-42 VDC maximum.

Input AC Power
Connector:

IEC 10-Amp input connector. The appendix titled "Cabling Specifications" lists the AC power cords for a variety of countries and regions.

AC Power Cable:

Provided with 8 feet (2.3 m) of 3-conductor wire with plug.

AC Plug at
Customer end

20 A NEMA L620, 3-prong plug (domestic U.S.)
13 A 250 Vac BS1363, 3-prong fused plug (UK, Ireland)
CEE 7/7 (Continental Europe)
AS3112 (Australia/New Zealand)
CEI23-16/VII (Italy)
125V/15A North America

DC Input Connections:

Three-position terminal block for 10 AWG wire (4 square millimeters).

Operating Environment:

0º-40º C (32º-104º F) normal operation (50º C or 122º F up to 72 hours). Maximum 85% relative humidity.

Shock:

Withstands 10 G, 10 ms at 1/2 sine wave.

Vibration:

Withstands 1/4 G, 20-500 Hz.

Heat Transfer to Environment:

AC-powered: 4,800 BTUs.
DC-powered: 4,100 BTUs.

SES Performance

CellBus bandwidth

Slots 3-5, 10-12:


Slots 6-7, 13-14


Serial line bandwidth



~160 Mbps per slot single speed
~320 Mbps per slot double speed

~160 Mbps per two slots single speed
~320 Mbps per two slots double speed

3.75 Gbps per slot

Alarm and error handling

Same as MGX 8850 and IGX 8400 series switches

SES Processor Switching Module Specifications

This section contains general specifications for the SES Processor Switching Module (SES- PXM). The information in Table A-1 includes information for the two types of back cards---the PXM-UI user interface for switch and the uplink card for trunking and CPE access.


Table A-2: PXM Specifications
Category Description

Maximum switch fabric throughput.

2 times OC12.

Control access:

These ports exits on the
PXM-UI back card.

Control port: RJ45 connector, EIA/TIA 232, DTE mode, asynchronous interface 19,200 baud, 1 start bit, 1 stop bit, no parity bits.

Maintenance port: RJ45 connector, EIA/TIA 232, DTE mode, asynchronous interface 9600 baud, 1 start bit, 1 stop bit, no parity bits.

LAN port: RJ45 connector, 10-baseT, 802.3 Ethernet.

Uplink ports and connectors:

An uplink card can have
one of these number and type of connectors. The wavelength on optical lines is 1310 nm.

4 OC3 multi-mode fiber, SC connectors
4 OC3 single-mode fiber, intermediate reach, SC connectors
4 OC3 single-mode fiber, long reach, SC connectors

Number of logical ports:

32 across all physical ports on the uplink card (regardless of line type).

LEDs on PXM front card:

LEDs display status, but alarm history is a switch.

Status for the card:

  • Green means active.

  • Red means failed.

  • Yellow indicates the standby card.

LAN activity: flashing green indicates activity.

Node alarm:

  • Red indicates major alarm.

  • Yellow indicates minor alarm.

Node power (note that each AC power supply also has an LED):

  • "DC OK A" is green for okay or red for trouble.

  • "DC OK B" is green for okay or red for trouble.

Alarm history: ACO

Port interface (for the Uplink port):

  • Green means active and okay.

  • Red means active and local alarm.

  • Yellow means active and remote alarm.

  • No light means inactive or not provided.

LEDs on back cards:

Green means active. No light means inactive or not provided.

Synchronization:

These clock sources satisfy Stratum 4 requirements.

8 KHz clock derived from the following sources:

  • Internal 8 KHz clock (10 ppm).

  • Service modules or trunk line interfaces.

  • External BITS clock port.

  • T1 clock rate 1.544 MHz ± 32 ppm.

  • E1 clock rate 2.048 MHz ± 50 ppm (can be either sync or data signal).

BITS clock interface:

E1/T1 with an RJ45 connector.

E1 with an SMB connector.

Trunk history counters:

Ingress, per connection:
Number of received cells with CLP=0.
Number of received cells with CLP=1.

Egress, per connection:
Number of received cells.
Number of transmitted cells.
Number of received cells with EFCI bit set.
Number of transmitted cells with EFCI bit set.

Connection capacities
supported by PXM:

Maximum number of connections:
16,000 bi-directional channels for local switching.
32,000 bi-directional channels for switching across uplink card.

Maximum aggregate bandwidth:
600 Mbps local switching (service module to service module).
1,200 Mbps switching across uplink.

Cell memory: 256K cells.

Processor clock speed and memory specifics:

Clock speed: 200 MHz internal, 50 Mhz external.

Flash memory: 2 Mbytes.

DRAM: 64 Mbytes, upgradeable to 128 Mbytes.

Secondary cache: 512 Kbytes.

BRAM: 128 Kbytes.

Hard disk: 6 Gbytes.

Alarm indicators (audible and visual):

Central office-compatible alarm indicators and controls through a DB15 connector.

Maintenance features:

Internal isolation loopback.
External remote loopback.
Hot-pluggable.

Card dimensions:

Front card: 15.65 inches by 16.83 inches (39.75 cm by 42.75 cm)
Back cards: 7.25 inches by 4.125 inches (18.42 cm by 10.48 cm)

Power:

Requires -48 VDC, dissipates 150 W.

AUSM/B-8T1E1 Interface Characteristics

This section contains details for the AUSM/B-8T1E1. For physical characteristics, see Table A-3. For the T1 and E1 characteristics, see Table A-4 and Table A-5, respectively. For ATM interface characterisitcs, see Table A-6. For statistics and counters, see Table A-7.


Table A-3: Physical Characteristics of the AUSM/B-8T1E1l
Category Description

LED Indicators Per Card:

Active (green), Standby (yellow), Fail (red)

LED Indicators Per Line:

One per line: Active and OK (green)
Active and Local Alarm (red)
Active and Remote Alarm (yellow)

Maintenance/Servicability:

Facility loopback via Loop up/down per ANSI T1.408 and
ATT TR 62411 (T1), CCITT G.7xx (E1)
Facility Loopback via Management Console
Internal Problem Isolation Loopbacks
Hot pluggable

Card Size:

Front card: 7.25" x 16.25" (18.43 cm x 41.28 cm)
Back cards: 7" x 4.5" (17.78 cm x 11.43 cm)

Power:

-48VDC, 30 W

Safety:

EN 60950 2nd edition (including EN 41003) UL 1950 2nd edition

Compliance:

T1: G.703, G.824
E1: G.703, G.823

ESD:

IEC 61000-4-2


Table A-4:
T1 Interface Characteristics
Category Description

Line Interface :

RJ48 (100 ohms) on the LM-RJ48-8T1 back card

Line Rate:

1.544 Mbps ± 50 bps (T1)

Synchronization:

Transmitter can be: loop-timed, Receiver, or synchronized to node (normal mode)

Line Code:

Bipolar 8 Zero Substitution (B8ZS) per ANSI T1.408 (T1)

Line Framing:

Extended Superframe Format (ESF 24 frame multiframe) per ANSI T1.408

ESF Maintenance:

Bit-oriented alarm and loopback messages of ESF Data Link per ANSI T1.408

Input Jitter Tolerance:

Per ITU-T G.824

Output Jitter:

Per ITU-T G.824 using normal mode synchronization.

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Physical Layer
Performance Statistics:

LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS


Table A-5:
E1 Interface Characteristics
Category Description

Line Interface Connector:

RJ48 (120 ohms) on LM-RJ48-8E1, or SMB (75 ohms) on LM-SMB-8E1

Line Rate:

2.048 Mbps ± 100 bps

Synchronization:

Transmitter can be: loop-timed, Receiver, or synchronized to shelf (normal mode)

Line Code:

HDB3 (E1)

Line Framing:

16-frame multiframe as in G.704

Input Jitter Tolerance:

As specified in ITU G.823 for 2.048 Mbps

Output Jitter Generation:

As specified in ITU G.823 for 2.048 Mbps

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Physical Layer Statistics:

LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS


Table A-6:
ATM Interface Characteristics
Category Description

Standards:

ATM UNI v3.1, ITU-T G.804, per CCITT I.361.

Channel Configuration:

1000 per card, across any of the T1 or E1 ports.

VPI/VCI Ranges:

VPI: 0-255.
VCI: 0-4096.

Traffic Classes:

CBR, VBR, VBR+.

UPC Parameters:

PCR, SCR (VBR), CCDV (CBR).

Congestion Control Support:

ForeSight (towards Network for VBR+).

ForeSight Parameters:

MIR, PIR, Rate Up, Rate Down, QIR, QIR Timeout, IBS.


Table A-7:
AUSM/B-8T1E1 Statistics and Counters
Counter Type Description

Per Port:

Number of cells received from the interface.
Number of cells received with unknown VPI/VCI.
Last known VPI/VCI received from the port.
Number of cells discarded due to error in Cell Header.
Number of cells received with non zero GRC field.
Number of cells transmitted to the interface.
Number of cells transmitted for which EFCI was set.
Number of egress cells discarded due to service interface physical alarm.

Endpoint (channel):

Ingress:

Number of cells received from port.
Number of cells received from the port with CLP = 1.
Number of cells received from the port with EFCI = 1.
Number of cells from the port discarded due to queue exceeded QDepth.
Number of cells (with CLP) set) discarded due to queue exceeded CLP threshold.
Number of cells from the port for which CLP was set due to UPC violations.

ATMizer channel Counters:

Ingress:

Number of cells transmitted to CellBus.
Number of cells to cell bus for which EFCI was set.
Number of cells to cell bus discarded due to shelf alarm.

Egress

Number of cells received from the CellBus.
Number of cells discarded due to queue exceeded QDepth (per Egress Q).
Number of cells discarded due to queue exceeded CLP threshold
(per Egress Q).

Number of cells received with CLP = 1.

Other Counters:

Ingress:

Number of OAM cells discarded.
Number of AIS cells received from the port.
Number of RDI (FERF) cells received from the port.
Number SegmentLpBk cells received from the port.
Number of SegmentLpBk cells transmitted to CellBus.

Egress:

Number of OAM cells discarded.
Number of AIS cells transmitted to the port.
Number of SegmentLpBk cells transmitted to the port.
Number of SegmentLpBk cells received from the port.

Diagnostic Statistics:

Peak Queue Depth (Ingress: per channel).

FRSM-2CT3 Specifications

This section provides details for the FRSM-2CT3. Topics consist of the following:


Table A-8: Frame Relay Interface Standards
Interface Standard

Frame Relay Interface

ANSI T1.618, 2-octet header

ATM Layer

CCITT I.361 and ATM UNI v3.1

AAL Layer

AAL5 per ITU-T I.363

FR-Cell Interworking

Per ITU-T I.555 and I.36x.1, as summarized in "ATM-to-Frame Relay Interoperability Implementation Agreement" v 1.0


Table A-9:
FRSM-2CT3 Front Card Physical Characteristics
Feature Significance or Value

Power

48 V DC, 60 W (estimated)

Card Status Indicator LEDs

Active (Green),
Failed (Red),
Standby (Yellow)

Line Status Indicator LEDs

Active & Okay (Green),
Active & Local Alarm (Red),
Active & Remote Alarm (Yellow)

Reliability

> 85000 hours MTBF (target)

Card Size

7.25 inches by 16.5 inches


Table A-10:
FRSM-2CT3 Line Level
Feature Significance or Value

Number of T3 Lines

Two

Line Interface Connector

75 ohm BNC

Line Rate

44.736 Mbps +/- 20 ppm

Line Coding

B3ZS

Transmit Timing

Normal or Loop timed

Input Jitter Tolerance

Per GR-449-CORE, ITU-T G.824

Output Jitter

0.05 UI maximum with jitter-free input clock

Output Pulse

Per T1.102.1993

FRSM-2CT3 Framer

The FRSM-2CT3 line framer:

FRSM-2CT3 Line Alarms

For line alarms, the FRSM-2CT3 supports:

FRSM-2T3E3 Specifications

This section provides details for the FRSM-2T3E3. Where appropriate, it has separate sections for T3 and E3 technologies. Topics consist of the following:


Table A-11: Frame Relay Interface Standards
Interface Standard

Frame Relay Interface

ANSI T1.618, 2-octet header

ATM Layer

CCITT I.361 and ATM UNI v3.1

AAL Layer

AAL5 ITU-T I.363

FR-Cell Interworking

Per ITU-T I.555 and I.36x.1, as summarized in "ATM-to-Frame Relay Interoperability Implementation Agreement" v 1.0


Table A-12:
FRSM-2T3E3 Front Card Physical Characteristics
Feature Significance or Value

Power

48 V DC, 60 W (estimated)

Card Status Indicator LEDs

Active (Green),
Failed (Red),
Standby (Yellow)

Line Status Indicator LEDs

Active & Okay (Green),
Active & Local Alarm (Red),
Active & Remote Alarm (Yellow)

Reliability

> 85000 hours MTBF (target)

Card Size

7.25 inches by 16.5 inches

FRSM-2T3E3 T3 Line

The T3 line characetristics appear in Table A-13.


Table A-13: T3 Line Level
Feature Significance or Value

Number of T3 Lines

Two

Line Interface Connector

75 ohm BNC

Line Rate

44.736 Mbps +/- 20 ppm

Line Coding

B3ZS

Transmit Timing

Normal or Loop timed

Input Jitter Tolerance

Per GR-499-CORE, ITU-T G.824

Output Jitter

0.05 UI maximum with jitter-free input clock

Output Pulse

Per ANSI T1.102

T3 Framer Level

For the framing characteristics of T3 operation, the FRSM-2T3E3:

FRSM-2T3E3 E3 Line

For characteristics of the line on an FRSM-2T3E3 with an E3 back card:


Table A-14: E3 Line Level
Feature Significance or Value

Number of E3 Lines

Two

Line Interface Connector

75 ohm BNC

Line Rate

34.368 Mbps +/- 20 ppm

Line Coding

HDB3

Transmit Timing

Normal or Loop timed

Input Jitter Tolerance

Per ITU-T G.823

Output Jitter

0.05 UI maximum with jitter-free input clock per AT&T TR54014

Output Pulse

Per ITU-T G.703

E3 Framer Level

For line framing, the E3 operation of the FRSM-2T3E3 complies with ITU-T G.751.

FRSM-2T3E3 Line Alarms

For line alarms, the FRSM-2T3E3 supports:

Statistics and Counter Specifications

See the section titled "Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2" for lists of applicable statistics and counters.

FRSM-HS2 Specifications

The FRSM-HS2 is the Frame Relay module with two HSSI ports. The topics in this section are:

For lists of the counters and statistics that are available on the FRSM - VHS series of cards, see the section titled "Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2."


Table A-15: Frame Relay Interface Standards
Interface Standard

Frame Relay Interface

ANSI T1.618, 2-octet header

ATM Layer

CCITT I.361 and ATM UNI v3.1

AAL Layer

AAL5 per ITU-T I.363

FR-Cell Interworking

Per ITU-T I.555 and I.36x.1, as summarized in ATM-to-Frame Relay Interoperability Implementation Agreement v 1.0


Table A-16:
FRSM-HS2 Physical Characteristics
Feature Significance or Value

Power

48 V DC, 75 W (estimated)
The SCSI2-2HSSI back card consumes 5 watts at 5 VDC and
6 watts at -5 VDC.

Card Status Indicator LEDs

Active (Green),
Failed (Red),
Standby (Yellow)

Line Status
Indicator LEDs

Active & Okay (Green),
Active & Local Alarm (Red),
Active & Remote Alarm (Yellow)

Reliability

> 85000 hours MTBF (target)

Card Size

Front card: 7.25" x 16.25" (18.43 cm x 41.28 cm)
Back card: 7" x 4.5" (17.78 cm x 11.43 cm)


Table A-17: FRSM-HS2 Line Characteristics
Feature Significance or Value

Number of HSSI Lines

Two

Connector Type

SCSI-2

Signaling Rate

52 Mbps max

Line Alarms

  • Control lead is inactive.

  • Recovered clock does not match configured line rate.

Synchronization

Transmitter may be either loop-timed to Receiver (DTE mode) or synchronized to shelf (DCE mode)

Electrical Interchange Characteristics

ITU-T V.12

Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2

This section lists counters and statistics that apply to most types of cards in the FRSM-VHS group.


Table A-18: Counters per Line
Counter

Received frames lost due to aborts

Received frames lost due to illegal header (EA bit)

Received frames lost due to CRC errors

Received frames with bit alignment errors

Received frames with unknown DLCI

Received frames with illegal frame length

Received good frame

Transmit frames lost due to under-run/Abort count

Transmit good frame

LMI status inquiry request count

LMI signaling protocol (keep alive time-out count)

LMI sequence number error count

LMI status transmit count (in response to request)

LMI update status transmit count (in response to configuration changes

Frames with FECN set count

Frames with BECN set count

DE frames discarded count

Number of frames reassembled but discarded due to service interface physical layer alarm


Table A-19: Service-Related Statistics
Service Statistic

Number of received frames

Number of bytes received

Number of frames received with DE=1

Number of frames received but discarded

Number of received bytes discarded

Number of frames received but discarded due to

CRC error
Illegal frame length
Alignment error
Abort

Number of frames reassembled and transmitted

Number of frames reassembled and transmitted with DE=1

Number of frames discarded due to reassembly errors

Number of frames transmitted

Number of bytes transmitted

Number of frames transmitted with DE set

Number of frames transmitted during LMI logical port alarm

Frames FECN set count

Frames BECN set count

Number of transmit frames discarded

Number of transmit bytes discarded

Number of transmit frames discarded due to:

CRC error
Illegal frame length
Alignment error
Abort
DE egress queue threshold exceeded
Physical link failure

Table A-20: ATM Cell-Related Statistics
ATM Cell Statistic

Number of cells transmitted to PXM

Number of cells discarded due to intershelf link alarm

Number of cells transmitted with CLP bit set

Number of AIS cells transmitted

Number of FERF cells transmitted

Number of BCM cells transmitted

Number of end-end loop-back cells transmitted

Number of segment loop-back cells transmitted

Number of cells received from PXM

Number of cells received with CLP bit set

Number of AIS cells received

Number of FERF cells received

Number of BCM cells received

Number of end-end loop-back cells received

Number of segment loop-back cells received

Number of OAM cells discarded due to CRC-10 error


Table A-21: Diagnostic-Related Statistics
Diagnostic Statistic

Header of last cell with unknown LCN

Header of last received frame with unknown DLCI

ECN current queue depth


Table A-22: Troubleshooting Statistics
Troubleshooting Statistic

ECN current queue depth, per channel

FRSM-8T1 Specification

This section provides information on the T1 operation of the FRSM-8T1E1 card set. Topics are


Table A-23: General Card Specifications
Category Description

Indicators per card:

Active (Green), Standby (Yellow), Fail (Red)

Indicators per line:

Active & Okay (Green)
Active & Local Alarm (Red)
Active & Remote Alarm (Yellow)

Line Interface connector:

RJ-48 when used with RJ48-8T1 back card

Line Rate:

1.544 Mbps ± 50 bps

Line Framing:

ESF per ATT TR 54016

Maintenance/Serviceability Features:

Internal Problem Isolation Loopbacks
Hot-pluggable cards

Reliability, MTBF:

> 65000 hours

Card Size:

FRSM-8T1: 7.25" x 16.25"
LM-DB15-8T1: 7.0" x 4.5"
Power: -48V DC, 30W with 8 active T1 lines


Table A-24:
Frame Relay Service With T1 Lines
Category Description

Synchronization:

Transmitter may be either loop-timed to Receiver or synchronized to shelf (called normal mode)

Input Jitter Tolerance:

Per ITU-T G.824

Output Jitter Generation:

Per ITU-T G.824 using normal mode synchronization

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Number of Frame Relay Ports:

One-a single Frame Relay stream occupying N consecutive time slots

Frame Relay Interface Rates:

Either of the following:

  • 56 Kbps

  • N x 64 Kbps (where N is the number of consecutive time slots)

Frame Relay Interface:

Per ANSI T1.618, 2-octet header

Frame Relay Performance Counters (per Port; n x DS0):

Received frames discarded due to Aborts
Received frames discarded due to illegal header (EA bit)(s)
Received frames discarded due to CRC errors (s)
Received frames discarded due to alignment errors (s)
Received frames discarded due to unknown DLCI (s)
Received frames discarded due to illegal frame length (s)
Received frames discarded due to DE threshold exceeded
Received frames with DE already set
Received frames with FECN already set
Received frames with BECN already set
Received frames tagged FECN
Received frames (s)
Received bytes (s)
Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (s)
Transmit bytes discarded due to egress Q-depth exceeded (s)
Transmit frames discarded due to egress DE threshold
exceeded Transmit frames (s)

Transmit bytes(s)
Transmit Frames with FECN set (s)
Transmit Frames with BECN set (s)

LMI receive status inquiry request count (s)
LMI transmit status inquiry request count
LMI invalid receive status count (s)
LMI signaling protocol (keep alive time-out count) (s)
LMI sequence number error count (s)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (s)
Transmit bytes during LMI alarm (s)
LMI update status transmit count (in response
to configuration changes)

Diagnostics (per port):

Last unknown DLCI received


Table A-25:
System Interface
Category Description

ATM Layer:

Per ITU-T I.361 and ATM UNI v3.1

AAL Layer:

AAL5 per ITU-T I.363

FR-Cell Interworking:

Per ITU-T I.555 and I.36x.1, as summarized in Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FRF.5


Table A-26:
List of Counters
Category Description

Channels (endpoints) per card:

256, which you can allocate across any of the interfaces

Service Counters:

Note that an (s) at the end of
the description means the
data in the counter is usable as
a statistic.

Number of frames received (s)
Number of bytes received (s)
Number of frames received with DE already set (s)
Number of bytes received with DE already set (s)
Number of frames received with unknown DLCI
Number of frames received but discarded (s)
Number of received bytes discarded (s)
Number of received bytes discarded due to exceeded Q-depth (s)
Number of frames received and discarded due to: intershelf alarm
exceeded DE threshold (s)
exceeded Q depth (s)
Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN

Number of frames transmitted (s)
Number of bytes transmitted (s)

Number of frames transmitted with DE set (s)
Number of frames discarded due to reassembly errors (s)
Number of frames transmitted during LMI logical port alarm(s)
Number of frames transmitted with FECN set (s)
Number of frames transmitted with BECN set (s)
Number of transmit frames discarded (s)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (s)
egress Q depth exceeded (s)
egress DE threshold exceeded source abort
physical link failure (T1)
ATM cells: Number of cells transmitted to PXM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (s)
Number of OAM FERF cells transmitted (s)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (s)
Number of OAM segment loopback cells transmitted
Number of cells received from PXM
Number of cells received with CLP bit set
Number of OAM AIS cells received (s)
Number of OAM FERF cells received (s)
Number of BCM cells received
Number of OAM end-end loopback cells received (s)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (s)

Statistics:

If any of the counters in the preceding category of Service Counters includes an "(s)," you can configure it for statistics usage.

Diagnostics:

Last unknown LCN received,
Number of cells with unknown LCN.

FRSM-8E1 Specification

This section provides information on the E1 operation of the FRSM-8T1E1 card set. Topics are:


Table A-27: General Card Specifications
Category Description

Line Interface connector:

RJ-48 when used with RJ-48-8E1 line module.
SMB when used with SMB-8E1 line module

Line Rate:

2.048 Mbps ± 100 bps

Synchronization:

Transmitter may be either loop-timed to Receiver or synchronized to shelf (normal mode)

Input Jitter Tolerance:

Per ITU-T G.823

Output Jitter Generation:

Per ITU-T G.823

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Indicators per card:

Active (Green), Standby (Yellow), Fail (Red)

Indicators per line:

Active & Okay (Green)
Active & Local Alarm (Red)
Active & Remote Alarm (Yellow)

Maintenance/Serviceability Features:

Internal Problem Isolation Loopbacks
Hot-pluggable cards

Reliability, MTBF:

> 65000 hours

Card Size:

FRSM-8E1: 7.25" x 16.25" (18.43 cm x 41.28 cm)
RJ48-8E1: 7.0" x 4.5" (17.78 cm x 11.43 cm)
SMB-8E1: 7.0" x 4.5" (17.78 cm x 11.43 cm)

Power:

-48V DC, 30W with 8 active E1 lines


Table A-28:
Frame Relay Service With E1 Lines
Category Description

Number of Frame Interfaces:

1-31 occupying n, where 1 < n < 31. Sum of all < 31 for CCS or 1-30 for CAS.

Frame Relay Interface Rates:

Either 56 Kbps or n x 64 Kbps, where n is the same as defined in the preceding item the preceding item "Number of Frame Interfaces."

Ingress:

8000 cell buffer shared between virtual channels/paths
standard usage parameter control (UPC)
Selective Cell Discard
Virtual Circuit Queuing
EFCI setting per VC

Egress:

8000 cell storage capacity shared between four ports
Up to 12 user-selectable egress queues per port
Selective Cell Discard
EFCI setting per Queue

Frame Relay Interface:

Per ANSI T1.618, 2-octet header

Frame Relay Performance Counters (per Port; n x DS0):

Received frames discarded due to Aborts
Received frames discarded due to illegal header (EA bit)(s)
Received frames discarded due to CRC errors (s)
Received frames discarded due to alignment errors (s)
Received frames discarded due to unknown DLCI (s)
Received frames discarded due to illegal frame length (s)
Received frames discarded due to DE threshold exceeded
Received frames with DE already set
Received frames with FECN already set
Received frames with BECN already set
Received frames tagged FECN
Received frames (s)
Received bytes (s)

Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (s)
Transmit bytes discarded due to egress Q-depth exceeded (s)
Transmit frames discarded due to egress DE threshold exceeded Transmit frames (s)
Transmit bytes(s)
Transmit Frames with FECN set (s)
Transmit Frames with BECN set (s)
LMI receive status inquiry request count (s)
LMI transmit status inquiry request count
LMI invalid receive status count (s)
LMI signaling protocol (keep alive time-out count) (s)
LMI sequence number error count (s)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (s)
Transmit bytes during LMI alarm (s)
LMI update status transmit count (in response to configuration changes)

Diagnostics (per port):

Last unknown DLCI that arrived


Table A-29:
System Interface
Category Description

ATM Layer:

Per ITU-T I.361 and ATM UNI v3.1

AAL Layer:

AAL5 per ITU-T I.363

FR-Cell Interworking:

Per ITU-T I.555 and I.36x.1, as summarized in Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FERF.5


Table A-30:
List of Counters
Category Description

Channels (Endpoints):

256 per card---can be allocated across any of the frame relay interfaces

Counters:

Service Counters: Number of frames received (s)
Number of bytes received (s)
Number of frames received with DE already set (s)
Number of bytes received with DE already set (s)
Number of frames received with unknown DLCI
Number of frames received but discarded (s)
Number of received bytes discarded (s)
Number of received bytes discarded due to exceeded Q-Depth (s)
Number of frames received and discarded due to

intershelf alarm

exceeded DE threshold (s)

exceeded Q depth (s)

Number of frames received with FECN set
Number of frames received with BECN set

Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (s)
Number of bytes transmitted (s)
Number of frames transmitted with DE set (s)
Number of frames discarded due to reassembly errors (s)
Number of frames transmitted during LMI logical port alarm(s)
Number of frames transmitted with FECN set (s)
Number of frames transmitted with BECN set (s)
Number of transmit frames discarded (s)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (s)
egress Q depth exceeded (s)
egress DE threshold exceeded source abort physical link failure (T1)

ATM cells: Number of cells transmitted to PXM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (s)
Number of OAM FERF cells transmitted (s)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (s)
Number of OAM segment loopback cells transmitted
Number of cells received from PXM
Number of cells received with CLP bit set
Number of OAM AIS cells received (s)
Number of OAM FERF cells received (s)
Number of BCM cells received
Number of OAM end-end loopback cells received (s)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (s)
Statistics: All of the above counters followed by an (s) can be configured as statistics.
Diagnostics: 8Last unknown LCN received
Cells with unknown LCN count
Card General

Circuit Emulation Service Module for T1 Operation

This section contains operational details for the CESM 8T1E1 with the RJ48-8T1 back card.


Table A-31: CESM 8T1 Card Information
Category Description

Back Card:

RJ48-8T1

Line Rate

T1: 1.544 Mbps ±50 bps

Transmit Clocking

Normal clock or SRTS generated

Line Coding

B8ZS

Frame mode

ESF

Line alarms

Loss or signal (LOS)
Loss of frame (LOF)
Loss of mulitframe (LOMF)
Remote loss of signal or frame (RAI)
All ones received (AIS)
Bipolar violation

Alarm indication times

Near end alarm up-count
Near end alarm down-count
Near end alarm maximum count
Far end alarm up-count
Far end alarm down-count
Far end alarm maximum count

Supported OAM cells:

AIS
FERF
End-to-end loopback
Segment loopback
RTD loopback
BCM

Physical Layer Performance Statistics

N/A

LED Indicators Per Card:

Active (green), Failed (red), Standby (yellow)

BERT

Active (green), Errors (yellow)

1 to N Redundancy

Active (green)

Indicator for each T1

Active (green)

Reliability, MTBF

Card Size

Front card: 7.25" x 16.25" (18.43 cm x 41.28 cm)
Back card: 7" x 4.5" (17.78 cm x 11.43 cm)

Power

48VDC, 30 W

Loopbacks

On or Off

Circuit Emulation Service Module for E1 Operation

This section contains operational details for the CESM-8T1E1 with an E1 back card.


Table A-32: CESM 8E1 Card Set Details
Category Description

Back Card

RJ48-8E or SMB-8E1

Line Rate

E1: 2.048 Mbps ± 100 bps (50 ppm)

Transmit Clocking

Normal clock or SRTS generated

Line Coding

HDB3

Frame mode

single frame
multiframe

Line alarms

Loss or signal (LOS)
Loss of frame (LOF)
Loss of mulitframe (LOMF)
Remote loss of signal or frame (RAI)
All ones received (AIS)
Bipolar violation

Alarm indication times

Near end alarm up-count
Near end alarm down-count
Near end alarm maximum count
Far end alarm up-count
Far end alarm down-count
Far end alarm maximum count

Supported OAM cells:

AIS
FERF
End-to-end loopback
Segment loopback
RTD loopback
BCM

Physical Layer Performance Statistics

N/A

Indicators:

Card-level

Active (green), Failed (red), Standby (yellow)

BERT

Active (green), Errors (yellow)

1 to N Redundancy

Active (green)

Indicator for each T1

Active (green)

Reliability, MTBF

Card Size

Front card: 7.25" x 16.25" (18.43 cm x 41.28 cm)
Back card: 7" x 4.5" (17.78 cm x 11.43 cm)

Power

48VDC, 30 W

Loopbacks

On or Off

Physical and Electrical Characteristics for Cards

For quick reference, Table A-33 shows physical dimensions and power consumption for each card. Detailed information for each card appears in the section of this appendix for a specific card.


Table A-33: Physical Characteristics and Power Consumption by Card

Module Back Cards Front Card Dimensions (inches) Back Card Dimensions (inches) Weight (front and back card) Power Consumption

FRSM-8T1

FRSM-8E1

FRSM-8T1c

FRSM-8E1c

8 T1, 8 E1

7.25 x 16.25

7.00 x 4.50

1.74 lbs/
0.76 lbs

30 watts

FRSM-2CT3

2 T3

7.25 x 16.25

7.00 x 4.50

1.74 lbs/
0.76 lbs

60 watts

FRSM-2T3E3

2 T3, 2 E3

7.25 x 16.25

7.00 x 4.50

1.74 lbs/
0.76 lbs

60 watts

FRSM-HS2

2 HSSI

7.25 x 16.25

7.00 x 4.50

1.74 lbs/
0.6 lbs

75 watts

CESM-8T1E1

8 T1, 8 E1

7.25 x 16.25

7.00 x 4.50

1.74 lbs
0.76 lbs

30 watts

AUSM/B-8T1E1

8-T1, 8-E1

7.25 x 16.25

7.00 x 4.50

1.74 lbs
0.76 lbs

30 watts

SES-PXM1

OC-3c/STM-1

15.65 x 15.83

7.00 x 4.5

4.80 lbs

100 watts

Electromagnetic Compatibility

This section lists the national and international standards for electromagnetic compatibility to which the Service Expansion Shelf complies. It consists of a list of reference documents, a table
(Table A-34) that indicates applicability of the standards, and the test levels for CE mark immunity.

The applicable standards for electromagnetic compatibility are

Details on how each standard applies in this Cisco product appear in Table A-34.


Table A-34: Electromagnetic Compatibility and Immunity
Category AC-Powered (110/220 VAC DC-Powered (-48V)

U.S.A EMC

FCC Part 15, Class A

not applicable

Japan EMC

Austel 3548 Class A

not applicable

Australia EMC

VCCI Class A

not applicable

CE mark

Immunity

EMC: EN 55022 Class A

  • EN 50082-1 (generic immunity)

  • EN 61000-4-2 through -5

not applicable

NEBS

(EMC)

not applicable

EMC:
GR-1089-CORE Class A (radiated and magnetic fields) and line conductance.

GR-1089-CORE ESD (8 KV contact) RS
(10 V/meter) CS (clause 3.3.3)

European Telecom Standards (ETSI) for Surge:
ETSI 300 386-1, DC power leads only
(200 VAC-1000 VAC)

The levels for the mandatory CE mark immunity tests are

Conformance

This section contains standards compliance information for features on the SES.

ATM UNI

The ATM specifications for the User-Network Interface to which the MGX 8850 complies are

SONET/SDH

The standards and responsible organizations with which MGX 8850 SONET technology complies are as follows:

Frame Relay

The standards and responsible organizations with which MGX 8850 Frame Relay technology complies are as follows:

Circuit Emulations Service

ATM Forum CES 2.0.

Safety

The SES enclosure meets all applicable regulatory agency Product Safety requirements.

Environmental

The SES adheres to the Bellcore GR-63-CORE environmental standard.