T3 Line Interface Connector: | BNC connector per ANSI T1.404 |
T3 Cable Recommended: | Coax, 75 ohm, 728A or equivalent |
T3 Line Signal: | DSX-3 Specification per ANSI T1.102 and ATT PUB 54014 |
T3 Line Rate: | 44.736 Mbps ± 895 bps |
T3 Framing: | Asynch. C-bit Parity per ANSI T1.107a |
Input Jitter Tolerance: | Per ATT TR 54014, Category II Equipment |
Output Jitter Generation: | Per ATT TR 54014, Table B1, "Equipment with DS3 Oscillator" Category |
PMD Layer Alarms: | LOS, OOF, AIS, RAI |
PMD Layer Performance Statistics: | LCV, LES,%EFS, LSES, SEFS, PCV, PES, PSES, SEFS, UAS |
Trans. Convergence Protocol: | PLCP per TR-TSV-000773 |
TC Layer Alarms: | OOF, RAI |
TC Layer Performance Statistics: | BIP8-CV, BIP8-ES, BIP8-SES, SEFS, UAS |
ATM Layer Protocol: | Header check sum is XORed with the COSET function (0x55) per CCITT I.361 |
ATM Layer Counters: | Number of cells received good |
Diagnostics: | Header of first cell received with invalid egress |
Synchronization: | Derives 8 kHz shelf synchronization clock
|
External Office clock interface: | DB15 connector via LM-T3E3-D (T1/E1 clock) |
Indicators: | Per Card: Active (Green), Failed (Red), Standby (Yellow) Minor DS-3 Statistical Alarm |
Maintenance/Serviceability Features: | Internal Isolation Loopbacks |
Reliability: | > 65000 hours MTBF |
Card Size: | BNM-T3: 7.25"x 16.25" |
Power: | -48V DC, 25W |
E3 Line Interface Connector: | BNC connector per ANSI T1.404 |
E3 Cable Recommended: | Coax, 75 ohm, 728A or equivalent |
E3 Line Signal: | Per G.703 |
E3 Line Rate: | 34.368 Mbps ± 20 PPM |
E3 Framing: | G.832 and G.804 |
Input Jitter Tolerance: | Per G.703 |
Output Jitter Generation: | Per G.703 |
PMD Layer Alarms: | LOS, OOF, AIS, RAI |
PMD Layer Performance Statistics: | LCV, LES, %EFS, LSES, SEFS, PCV, PES, PSES, SEFS, UAS |
Trans. Convergence Protocol: | PLCP per TR-TSV-000773 |
TC Layer Alarms: | OOF, RAI |
TC Layer Performance Statistics: | BIP8-CV, BIP8-ES, BIP8-SES, SEFS, UAS |
ATM Layer Protocol: | Header check sum is XORed with the COSET function (0x55) per CCITT I.361 |
ATM Layer Counters: | Number of cells received good Number of cells received and discarded due to bad HEC Number of cells transmitted good Number of cells received from cell bus Number of cells transmitted to cell bus |
Diagnostics: | Header of first cell received with invalid egress translation entries Number of cells dropped due to invalid egress translation entries Number of unacknowledged cells transmitted to cell bus |
Synchronization: | Derives 8 kHz shelf synchronization clock from a variety of sources:
|
External Office clock interface: | DB15 connector via LM-T3E3-D (T1/E1 clock) |
Alarm interface: | CO compatible alarm indicator and controls DB15 connector |
Indicators: |
|
Per Card: | Active (Green), Failed (Red), Standby (Yellow) |
E3 Interface: | Active & Okay (Green) Minor DS-3 Statistical Alarm |
Shelf Voltage: | A voltage OK (Green) B voltage OK (Green) |
Alarms: | Major (Red), Minor (Yellow) ACO (Yellow), History (Green) |
Maintenance/Serviceability Features: | Internal Isolation Loopbacks External remote loopback Hot-pluggable |
Card Size: | BNM-T3: 7.25" x 16.25" LM-T3E3-D: 7.25" x 4.5" LM-T3E3-B: 7.25" x 4.5" |
Power: | -48V DC, 25W |
Framing: | SONET STS-3c per ANSI T1.105 |
PMD Layer Alarms: | Loss of Signal (LOS) |
Transmission Convergence Protocol: | Per GR-253-CORE and ANSI T1.105 |
TC Layer Alarm: | Loss of Cell Delineation ((LCD) |
ATM Layer Protocol: | Header check sum is XORed with the COSET function (0x55) per CCITT I.361 |
ATM Layer Counters: | Number of cells received good |
Diagnostics: | Number of cells received from cell bus |
SMF Line Interface Connector | SC connectors |
Fiber Recommendation | Single-mode |
Maximum Fiber Length | 20 km |
SMF Line Signal | Optical, SONET OC-3c per ANSI T1.105 and GR-253-CORE |
SMF Line Rate | 155.52 Mbps |
Input Jitter Tolerance | Per Gr-253-CORE |
Output Jitter Generation | Per Gr-253-CORE |
Synchronization | Derives 8 kHz shelf synchronization clock from a variety of sources: |
External Clock Interface | DB-15 connector or BNC connector (both are available) |
Alarm Interface | CO compatible alarm indicator and controls via DB-15 connector |
Indicators | Ten LEDs |
· Per Card | Active (Green) |
· OC-3 Interface | Single multihue LED |
· Shelf Voltage | A Voltage OK (Green) |
· Alarms | Major (Red) |
Maintenance Serviceablity Features | Internal isolation loopbacks |
· Reliability | > 65000 hours MTBF |
· Card Size | BNM-155: 7.25" x 16.25" |
· Power | -48V DC, 25W |
802.3 LAN Interface Connector: | AUI interface via DB-15 connector Control port: DB-25 RS232 connector; Asynch interface, 99200 baud, 1 start, |
Trouble shooting interface: | Maintenance port: DB-25 RS232 connector; Asynch interface, 9600 baud, 1 start, 1 stop, no parity |
Indicators: | Per Card: Active (Green), Failed (Red), Standby (Yellow) LAN activity/Flashing green |
Maintenance/ Serviceability Features: | RS232 maintenance/debug port Internal Isolation Loopbacks Hot-pluggable |
Reliability: | > 65000 hours MTBF |
Card Size: | ASC: 7.25" x 16.25" LM_ASC: 7.0" x 4.5" |
Power: | -48V DC, 25W |
T1/E1 Line Interface Connector: | BNC-3T# |
Line Rate: | T1: 1.544 Mbps ±75 bps (50 ppm) |
Transmit Clocking: | Normal or Looped timed |
Input Jitter Tolerance: | Per AT&T Accunet T1.5 Service 1990 - T1 |
Physical Layer Alarms: | Indicated in Service Modules |
Physical Layer Performance Statistics: | N/A |
Indicators: |
|
Per Card: | Active (green), Failed (red), Standby (yellow) |
BERT: | Active (green), Errors (yellow) |
1 to N Redundancy: | Active (green) |
Indicator for each T3: | Active (green) |
Maintenance/Serviceability Features: | DS1 Loopback toward service modules |
Reliability: | >85000 hous MTBF |
Card Size: | Front card 7.25" x 16.25" |
Power: | 48V DC, 50 W |
Loopback codes: | Fractional T1 in-band loopback - DS0 loopback - |
Monitoring trouble codes: | TA-TSY-000077 |
Line Interface connector: | DB15---when used with LM-DB15-4T1 line module |
Line Rate: | 1.544 Mbps ± 50 bps |
Line Framing: | ESF per ATT TR 54016 |
Synchronization: | Transmitter may be either loop-timed to Receiver or synchronized to shelf (called normal mode) |
Input Jitter Tolerance: | Per ATT TR 62411 |
Output Jitter Generation: | Per ATT TR 62411 using normal mode synchronization |
Physical Layer Alarms: | LOS, OOF, AIS, RAI |
Number of Frame Relay Ports: | 1-Single Frame Relay stream occupying n consecutive time slots |
Frame Relay Interface Rates: | Either 56 kbps or n* 64 kbps; nas defined above |
Frame Relay Interface: | Per ANSI T1.618, 2-octet header |
Frame Relay Performance Counters (per Port; n x DS0): | Receive frames discarded due to Aborts |
| Transmit bytes(s) |
| LMI receive status inquiry request count (s) |
Diagnostics (per port): | Last unknown DLCI received |
ATM Layer: | Per CCITT I.361 and ATM UNI v3.1 |
AAL Layer: | AAL5 per Draft CCITT I.363 |
FR-Cell Interworking: | Per Draft CCITT I.555 and I.36x.1, as summarized in Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FRF.5 |
Channels (Endpoints): | 256 per card---may be allocated across any of the frame relay interfaces |
Counters: |
|
Service Counters: | Number of frames received (s) |
| Number of frames transmitted (s) |
| Number of frames transmitted with DE set (s) |
Statistics: | All of the above counters followed by an (s) can be configured as statistics |
Diagnostics: | Last unknown LCN received Cells with unknown LCN count |
Indicators: |
|
Per Card: | Active (Green), Standby (Yellow), Fail (Red) |
Lines (one per): | Active & Okay (Green) |
Maintenance/Serviceability Features: | Internal Problem Isolation Loopbacks Hot-pluggable |
Reliability: | > 65000 hours MTBF |
Card Size: | FRSM-4T1: 7.25" x 16.25" |
Line Interface connector: | DB15 when used with LM-DB15-4E1 line module. BNC when used with LM-BNC-4E1 line module. |
Line Rate: | 2.048 Mbps ± 100 bps. |
Synchronization: | Transmitter may be either loop-timed to receiver or synchronized to shelf (called normal mode). |
Input Jitter Tolerance: | Per G.703. |
Output Jitter Generation: | Per G.703. |
Physical Layer Alarms: | LOS, OOF, AIS, RAI. |
Number of Frame Interfaces: | I to 31 occupying n where 1 < n < 31. Sum of all < 31 for CCS. 1-30 for CAS. |
Frame Relay Interface Rates: | Either 56 kbps or n* 64 kbps; n as defined above. |
Frame Relay Interface: | Per ANSI T1.618, 2-octet header. |
Frame Relay Performance Counters (per Port; n x DS0): | Receive frames discarded due to Aborts |
| Transmit frames discarded due to underrun |
Diagnostics (per port): | Last unknown DLCI received |
ATM Layer: | Per CCITT I.361 and ATM UNI v3.1 |
AAL Layer: | AAL5 per Draft CCITT I.363 |
FR-Cell Interworking: | Per Draft CCITT I.555 and I.36x.1, as summarized in "Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FERF.5" |
Channels (Endpoints): | 256 per card---may be allocated across any of the frame relay interfaces |
Counters: | Service Counters: Number of frames received (s) |
| Number of frames received tagged FECN |
| ATM cells: Number of cells transmitted to BNM |
Indicators: | Per Card: Active (Green), Standby (Yellow), Fail (Red) |
Maintenance/Serviceability Features: | Internal Problem Isolation Loopbacks |
Card Size: | FRSM-4E1: 7.25" x 16.25" |
Power: | -48V DC, 30W (4 E1s) |
Ingress: | 8000 cell buffer shared between virtual channels/paths |
Egress: | 8000 cell storage capacity shared between four ports |
Line Interface connector: | RJ-48 when used with LM-RJ-48-8T1 line module. |
Line Rate: | 1.544 Mbps ± 50 bps |
Line Framing: | ESF per ATT TR 54016 |
Synchronization: | Transmitter may be either loop-timed to receiver or synchronized to shelf (called normal mode) |
Input Jitter Tolerance: | Per ATT TR 62411 |
Output Jitter Generation: | Per ATT TR 62411 using normal mode synchronization |
Physical Layer Alarms: | LOS, OOF, AIS, RAI |
Number of Frame Relay Ports: | 1-Single frame relay stream occupying n consecutive time slots |
Frame Relay Interface Rates: | Either 56 kbps or n * 64 kbps; n as defined above |
Frame Relay Interface: | Per ANSI T1.618, 2-octet header |
Frame Relay Performance Counters (per Port; n x DS0): | Receive frames discarded due to Aborts |
| Transmit bytes(s) |
| LMI receive status inquiry request count (s) |
Diagnostics (per port): | Last unknown DLCI received |
ATM Layer: | Per CCITT I.361 and ATM UNI v3.1 |
AAL Layer: | AAL5 per Draft CCITT I.363 |
FR-Cell Interworking: | Per Draft CCITT I.555 and I.36x.1, as summarized in Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FRF.5 |
Channels (Endpoints): | 256 per card---may be allocated across any of the frame relay interfaces |
Counters: |
|
Service Counters: | Number of frames received (s) |
| Number of frames transmitted (s) |
| Number of frames transmitted with DE set (s) |
Statistics: | All of the above counters followed by an (s) can be configured as statistics |
Diagnostics: | Last unknown LCN received cells with unknown LCN count |
Indicators: |
|
Per Card: | Active (Green), Standby (Yellow), Fail (Red) |
Lines (one per): | Active & Okay (Green) |
Maintenance/Serviceability Features: | Internal Problem Isolation Loopbacks Hot-pluggable |
Reliability: | > 65000 hours MTBF |
Card Size: | FRSM-8T1: 7.25" x 16.25" |
Line Interface connector: | RJ-48 when used with LM-RJ-48-8E1 line module. |
Line Rate: | 2.048 Mbps ± 100 bps |
Synchronization: | Transmitter may be either loop-timed to receiver or synchronized to shelf (called normal mode) |
Input Jitter Tolerance: | Per G.703 |
Output Jitter Generation: | Per G.703 |
Physical Layer Alarms: | LOS, OOF, AIS, RAI |
Number of Frame Interfaces: | I to 31 occupying n where 1 < n < 31. Sum of all < 31 for CCS 1-30 for CAS |
Frame Relay Interface Rates: | Either 56 Kbps or n * 64 kbps; n as defined above |
Frame Relay Interface: | Per ANSI T1.618, 2-octet header |
Frame Relay Performance Counters (per Port; n x DS0): | Receive frames discarded due to Aborts |
| Transmit frames discarded due to underrun |
Diagnostics (per port): | Last unknown DLCI received |
ATM Layer: | Per CCITT I.361 and ATM UNI v3.1 |
AAL Layer: | AAL5 per Draft CCITT I.363 |
FR-Cell Interworking: | Per Draft CCITT I.555 and I.36x.1, as summarized in "Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FERF.5" |
Channels (Endpoints): | 256 per card---may be allocated across any of the frame relay interfaces |
Counters: | Service Counters: Number of frames received (s) |
| Number of frames received tagged FECN |
| ATM cells: Number of cells transmitted to BNM |
Indicators: | Per Card: Active (Green), Standby (Yellow), Fail (Red) |
Maintenance/Serviceability Features: | Internal Problem Isolation Loopbacks |
Card Size: | FRSM-8E1: 7.25" x 16.25" |
Power: | -48V DC, 30W (8 E1s) |
Ingress: | 8000 cell buffer shared between virtual channels/paths |
Egress: | 8000 cell storage capacity shared between four ports |
Receive frames lost due to Aborts
Receive frames lost due to illegal header (EA bit)
Receive frames lost due to CRC errors
Receive frames with bit alignment errors
Receive frames with unknown DLCI
Receive frames with illegal frame length
Receive good frame
Transmit frames lost due to under-run/Abort count
Transmit good frame
LMI status inquiry request count
LMI signaling protocol (keep alive time-out count)
LMI sequence number error count
LMI status transmit count (in response to request)
LMI update status transmit count (in response to configuration
changes
Frames FECN set count
Frames BECN set count
DE frames discarded count
No. of frames reassembled but discarded due to service
interface physical layer alarm
Trouble shooting statistics: ECN current queue depth (per channel)
Statistics
Service: No. of frames received
No. of bytes received
No. of frames received with DE = 1
No. of frames received but discarded
No. of received bytes discarded
No. of frames received but discarded due to:
- CRC error
- illegal frame length
- alignment error
- Abort
No. of frames reassembled and transmitted
No. of frames reassembled and transmitted with DE=1
No. of frames discarded due to reassembly errors
No. of frames transmitted
No. of bytes transmitted
No. of frames transmitted with DE set
No. of frames transmitted during LMI logical port alarm
Frames FECN set count
Frames BECN set count
No. of transmit frames discarded
No. of transmit bytes discarded
No. of transmit frames discarded due to:
- CRC error
- illegal frame length
- alignment error
- Abort
- exceeding DE egress queue threshold
- physical link failure
ATM cells No. of cells transmitted to BNM
No. of cells discarded due to intershelf link alarm
No. of cells transmitted with CLP bit set
No. of AIS cells transmitted
No. of FERF cells transmitted
No. of BCM cells transmitted
No. of end-end loop-back cells transmitted
No. of segment loop-back cells transmitted
No. of cells received from BNM
No. of cells received with CLP bit set
No. of AIS cells received
No. of FERF cells received
No. of BCM cells received
No. of end-end loop-back cells received
No. of segment loop-back cells received
No. of OAM cells discarded due to CRC-10 error
Diagnostics: Header of last cell with unknown LCN
Header of last received frame with unknown DLCI
ECN current queue depth
Line Interface Connector: | Miniature 15 pin female DB-15 (100 |
Line Rate: | 1.544 Mbps ± 50 bps (T1). |
Synchronization: | Transmitter may be either loop-timed or receiver or synchronized to shelf (called normal mode). |
Line Code: | Bipolar 8 Zero Substitution (B8ZS) as specified in ANSI T1.408 (T1). |
Line Framing: | Extended Superframe Format (ESF 24 frame multiframe) as ANSI T1.408. |
ESF Maintenance Functions: | Bit-oriented alarm and loopback messages of ESF Data Link as per ANSI T1.408. |
Input Jitter Tolerance: | Per ATT TR 62411. |
Output Jitter Generation: | Per ATT TR 62411 using normal mode synchronization. |
Physical Layer Alarms: | LOS, OOF, AIS, RAI. |
Physical Layer Performance Stats: | LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS. |
Line Interface Connector: | Miniature 15 pin female DB-15 (120 |
Line Rate: | 2.048 Mbps ± 100 bps (E1). |
Synchronization: | Transmitter may be either loop-timed or receiver or synchronized to shelf (called normal mode). |
Line Code: | HDB3 (E1). |
Line Framing: | 16 frame Multiframe as in G.704. |
Input Jitter Tolerance: | As specified in ITU G.823 for 2.048 mbps. |
Output Jitter Generation: | As specified in ITU G.823 for 2.048 mbps. |
Physical Layer Alarms: | LOS, OOF, AIS, RAI. |
Physical Layer Performance Stats: | LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS. |
| ATM UNI v3.1, ITU-T G.804, per CCITT I.361. |
Channel Configuration: | 256 per card. May be allocated across any of the T1 (E1) ports. |
VPI/VCI: | VPI: 0-255. |
Traffic Classes: | CBR, VBR, VBR+. |
UPC Parameters: | PCR, SCR (VBR), CCDV (CBR). |
Congestion Control Support: | ForeSight (toward Network for VBR+). |
ForeSight Parameters: | MIR, PIR, Rate Up, Rate Down, QIR, QIR Timeout, IBS. |
Counters: |
|
Per Port: | Number of cells received from the interface. |
Endpoint (channel): |
|
Ingress: | Number of cells received from port. |
ATMizer channel counters: |
|
Ingress: | Number of cells transmitted to cell bus. |
Egress: | Number of cells received from the cell bus. |
Other Counters: | . |
Ingress: | Number of OAM cells discarded. |
Egress: | Number of OAM cells discarded. |
Diagnostic Stats: | Peak Queue Depth (Ingress: per channel). |
Indicators: |
|
Per Card: | Active (green), Standby (yellow), Fail (red) |
Per Line: | One per line: Active & OK (green) |
Maintenance/Servicability: | Facility loopback via Loop up/down per ANSI T1.408 & ATT TR 62411 (T1), CCITT G.7xx (E1) |
Card Size: | 7.25" x 15" |
Power: | -48V DC, 30 W |
Safety: | EN 60950 2nd edition (including EN 41003) UL 1950 2nd edition |
Compliance: | T1: Accunet 62411 E1: G.703, G.823 |
ESD: | IEC 1000-4-2 |
![]() |
Note The CESM-4T1/E1 specification is the same as the FRSM-4T1/4E1 specification except as shown below. |
Synchronization: | Transmitter is synchronized to the shelf (Stratum traceable) |
Line Framing: | None |
Channel Configuration: |
|
Number of CBR Interfaces: | 4 |
Cell Delay Variation (CDV): | Configurable by setting reassembly buffer depth to a maximum of 250 msec. CDV = 1/2 buffer depth |
Channels (Endpoints): | One per physical port | |
Counters: |
| MIB Name |
AAL1: |
|
|
| Number of lost SAR-PDUs | cesLostCells |
Diagnostic: | Egress buffer depth (per port) |
|
Alarms: |
| MIB Name |
T1/E1 Port: | Red, Loss of Signal (LOS) Blue, Alarm Indication Signal (AIS) | LineAlarmState---bit 5 set LineAlarmState---bit 2, set and cesChanState = 3 |
| Line Code Violation (LVC) | LineStatisticalAlarmState |
SAR Port: |
|
|
Transmit state: | SendingAIS Sending FERF | cesXmtATMState = 3 cesXmtATMState = 4 |
Receiving state: |
|
|
| Receiving AIS Receiving FERF Cell Loss | cesRcvATMstate = 3 cesRcvATMstate = 4 cesCellLossStatus = 2 |
![]() |
Note All service specific alarms, except RED, will be passed through transparently. Loss of Signal (RED) at CBR interface will result in All 1's cells being transmitted. Brief periods of cell loss "Starvation" will result in insertion of 47 octects of 1's. Extended periods of cell loss will result in All 1's (Unframed AIS) being generated. During periods of cell bus configuration SAR-PDUs will be discarded. |
T1 Line Interface connector: | Miniature RJ-48C, 100 ohms balanced |
T3 Line Interface connector: | BNC, 75 ohms unbalanced |
Physical Interface (E3.E1) RJ48-E3E1-LM: |
|
E1 Line Interface connector: | Miniature RJ-48C, 100 ohms balanced |
E3 Line Interface connector: | BNC, 75 ohms unbalanced |
Physical Interface (E3.E1B) SMB-E3E1-LM: |
|
E1 Line Interface connector: | Miniature SMB, 75 ohms unbalanced |
E3 Line Interface connector: | Miniature SMB, 75 ohms unbalanced |
Line rate: | 1.544 Mbps +/- 50 bps. |
IMATM Synchronization: | Digital PLL to synchronize all transmitters to one of the following: the T3 line, any of the T1 lines, or the MGX 8220 shelf 8 kHz clock. |
Line Code: | Bipolar 8 zero substitution (B8ZS) as specified in ANSI T1.408. |
Line Framing: | Extended Superframe Format (ESF 24 frame multiframe) as in ANSI T1.408. |
Input Jitter Tolerance: | Per ATT TR 62411. |
Output Jitter Generation: | Using normal mode synchronization per ATT TR 62411. |
Physical Layer Alarms: | LOS, OOF, AIS, RDI. |
Physical Layer Performance Parms: | LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS. |
Line rate: | 2.048Mbps +/- 100 bps. |
IMATM Synchronization: | Digital PLL to synchronize all transmitters to one of the following: the E3 line, any of the E1 lines, or the MGX 8220 shelf 8 kHz clock. |
Line Code: | HDB3 (E1). |
Line Framing: | 16 frame multiframe as in G.704. |
ESF Maintenance Functions: | None. |
Input Jitter Tolerance: | As specified in ITU G.823 for 2.048 mbps. |
Output Jitter Generation: | As specified in ITU G.823 for 2.048 mbps. |
Physical Layer Alarms: | LOS, OOF, AIS, RDI. |
Physical Layer Performance Parms: | LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS. |
Line Rate: | 44.736 Mbps ±20 ppm (T3) |
Line Code: | B3ZS for DS3 |
Framing: | Physical Layer Conversion Procedure for DS3 to ANSI TA-TSY-000772 and TA-TSY-000773 |
Input Compliance: | Per ATT 54014 and CCITT G.703 |
Line Rate: | 34.368 Mbps ±20 ppm (T3). |
Line Code: | HDB3 for E3. |
Framing: | Per ITU-T Recommendation G.804 and G.832. |
Input Jitter Tolerance: | Per ATT TR 62411. |
ATM Interface: |
|
Cell support (type) | STI cells. |
Congestion Control: | EFCI/FFCI setting on Egress (AIM). |
EFCI setup: | Via programmable EFCI threshold. |
IMATM Alarms: | IMATM complies with DS3 and G.832 physical layer protocols. Supports FERF, LOS, LOF, OOF, AIS, yellow and red alarms. |
Counters: |
|
High Speed Port: | DS3/E3 physical layer line alarm indication and insertion |
AIM Group: | Number of cells received from AIM interface |
| Number of cells served from Egress queue to AIM interface |
ATMizer (Cellbus) counters: |
|
Ingress: | Numberof cells transmitted |
Egress: | Number of cells received |
Indicators: |
|
Per Card: | Active (Green), Standby (Yellow), Fail (Red) |
Lines (one per): | Active and OK (Green) |
Maintenance/Serviceability Features: | Internal Problem Isolation Loopbacks |
Card Size: | IMATM front card: 7.25" x 16.25" |
Power: | -48V DC |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Feb 9 13:30:31 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.