|
|
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar, select Documentation, and click Enter the feedback form. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.
Release 1.1.12 of the SES feeder for IGX supports the following configuration highlighted below:
1. Feeder concentration to the IGX 8400 is supported in this release using Switch Software 9.2.23. Only one feeder trunk is supported.
The SES feeder for IGX contains a 45 Gbps backplane with a 1.2 Gbps switching fabric for release 1.1.12. The same backplane is used with different switching fabric cards (1.2, 45 Gbps) to achieve scalability. The SES feeder for IGX release 1.1.12 hardware components and their revisions that are supported are as follows:
| Front card model # | Rev # | Back card model # | Rev # |
|---|---|---|---|
SES-IGX Chassis | A |
|
|
MGX-DC power supply PS-1200-AC power supply | A A |
|
|
SES-PXM | A | PXM-UI | A |
SES-PXM-4-155 | A | PXM-UI MGX-MMF-4-155 MGX-SMFIR-4-155 MGX-SMFLR-4-155 | A A A A |
AX-CESM-8E1 | A | AX-SMB-8E1 AX-RJ48-8E1 AX-R-SMB-8E1 AX-R-RJ48-8E1 |
|
AX-CESM-8T1 | A | AX-RJ48-8T1 AX-R-RJ48-8T1 |
|
MGX-AUSM-8E1/B | A | AX-SMB-8E1 AX-RJ48-8E1 AX-R-SMB-8E1 AX-R-RJ48-8E1 |
|
MGX-AUSM-8T1/B | A | AX-RJ48-8T1 AX-R-RJ48-8T1 |
|
AX-FRSM-8E1 | AC | AX-SMB-8E1 AX-RJ48-8E1 AX-R-SMB-8E1 AX-R-RJ48-8E1 |
|
AX-FRSM-8E1-C | AC | AX-SMB-8E1 AX-RJ48-8E1 AX-R-SMB-8E1 AX-R-RJ48-8E1 |
|
AX-FRSM-8T1 | AC | AX-RJ48-8T1 AX-R-RJ48-8T1 |
|
AX-FRSM-8T1-C | AC | AX-RJ48-8T1 AX-R-RJ48-8T1 |
|
MGX-FRSM-HS2/B | A | MGX-SCSCI2-2HSSI/B | A |
MGX-FRSM-2CT3 | A | MGX-BNC-2T3 | A |
MGX-FRSM-2T3E3 | A | MGX-BNC-2E3 MGX-BNC-2E3A | A A |
1. The SES feeder for IGX provides high speed native ATM interfaces which can be configured as ATM trunks (only one trunk supported)
2. Service module and PXM upgrades
For more details refer to the CWM Release 9.2.05 release notes part number 78-6659-06
The SNMP SES feeder for IGX MIB is being provided with the delivery of Release 1.1.12 of the SES feeder for IGX software on CCO. The MIB is in standard ASN.1 format and is located in the in the same directory within CCO. These files may be compiled with most standards-based MIB compilers.
The SES feeder for IGX does not support the 42 MHz clock on the cell bus. (See CSCdp27092)
The correct order for the restore procedure is:
Step 1 saveallcnf
Step 2 install
Step 3 newrev
Step 4 commit
Step 5 restoreallcnf
Do NOT execute the restoreallcnf command in the middle of the installation process. If you follow the following steps:
Step 1 saveallcnf
Step 2 restoreallcnf
Step 3 install
Step 4 newrev
Step 5 commit
The dsplns command will display a line as disabled, but you cannot run an addln command. Do not execute the restoreallcnf command until the install and newrev commands have completed.(for more information, refer to CSCdm57683)
For VHS service module redundancy support, y-cabling is required.
MGX 8220 service modules (AX-FRSM-8T1/E1, and AX-CESM-8T1/E1) need to have the boot flash upgraded to MGX 8220 release 5.0.00 common boot code(1.0.01 version) before they can be plugged in the SES feeder for IGX chassis. All MGX 8220 service module versions that do not use this common boot code (release 2.0.xx, 3.0.xx, 4.0.xx of boot code) are not supported in the SES feeder for IGX.
If loading of the correct common boot code image is required then it will have to be performed on an MGX 8220 chassis, and cannot be performed on an SES feeder for IGX chassis. Please refer to the procedure below.
Step 1 Use ftp to port the Axis 5 common boot image for the service module to a workstation
Step 2 Plug in the card into the MGX 8220 shelf
Step 3 Download the proper MGX 8220 shelf release 5.0 boot image using the following commands from the workstation:
tftp <ip address of the MGX 8220 shelf > bin put <boot filename> AXIS_SM_1_<slot#>.BOOT
Now you must insure that tftp downloaded the appropriate boot code by verifying the flash checksums.
Step 1 Login to the shelf.
cc <slot #>' chkflash'
Step 2 Verify that the two checksums are the same.
If NOT, repeat the process until they are the same. If they are the same, then you can safely remove the card. At this point the service module can be used in the SES feeder for IGX shelf.
A minimum of two and up to four IP addresses are needed to be configured for SES feeder for IGX (one or more of the following: ethernet, ATM, SLIP) and the boot IP address. The user should use "bootChange" to set up IP gateway when the PXM card is just installed. The IP default gateway should be on the same subnet as the PXM board. Use the bootChange command to set correct IP address, netmask, and default gateway.
You can only configure an AUSM service module as the clock source. If you try to configure an FRSM-8E1/T1 as the clock source, the error message displays that the service module does not provide clock driving support, but the dspclksrc command shows FRSM-8T1/E1 even though it is the previous configured AUSM clock source (CSCdm38800)
To configure the external clock source use the interface label 1.35. Do not use 0.33 or 1.33
You must reboot your PXM after each modification with "bootChange" for it to take effect. Also make sure the subnet mask is 255.255.0.0
. bootChange
- Only enter the ethernet IP address, netmask and default gateway.
- Type "." to erase incorrect entries.
tigers.1.1.PXM.a > bootChange
'.' = clear field; '-' = go to previous field; ^D = quit
boot device :lnPci
processor number :0
host name :C <-- Please put "C".
file name :
inet on ethernet (e) :172.29.37.40:ffffff00 <-- Ethernet IP Addr/Netmask
inet on backplane (b):
host inet (h) :
gateway inet (g) :172.29.37.1 <-- Default Gateway
user (u) :
ftp password (pw) (blank = use rsh):
flags (f) :0x0
target name (tn) :
startup script (s) :
other (o) :
- Type in reboot, after this the command "ping" will work:
tigers.1.1.PXM.a > ping 171.71.54.53 1
171.71.54.53 is alive
Configuration save and restore is only supported through the CLI (CWM does not support configuration save and restore).- Service module upgrades error handling is not provided. If the user skips any of the steps during upgrade or if a power failure happens in the middle of the upgrade, results will be unpredictable. See the Special Installation and Upgrade requirements section for service module upgrades. To recover from procedural errors contact your TAC support personnel.
The SES feeder for IGX supports 15 simultaneous telnet sessions and 10 tftp sessions.
You must use the following Y cables for FRSM-HS2 and FRSM-CT3 redundancy as specified in the Product Orderability Matrix (Straight Cable: 72-0710-01, Crossover Cable: 72-1265-01, Straight Y-cable: FRSM-HS2: CAB-SCSI2-Y, FRSM-CT3: CAB-T3E3-Y). Other cables are not supported.
Y cable redundancy for FRSM-HS2, FRSM-2CT3, FRSM-2T3, FRSM-2E3 is only supported for adjacent slots.
Cooling and Power limitations: Customer should be aware of the need for extra power supplies and fans beyond certain limitations. A single fan tray will support all configurations that draw between 1200 and 1400 watts. For power requirements, the SES feeder for IGX requires a minimum of one power supply to support the power requirement for 5 cards.
| 0-5 cards | 6-10 cards | 11 and above |
Single Line Cord (N+1): | 1 | 1 | 2 |
This is based on an estimated worst case power requirement of 150W plus margin per card slot.
CONNECTION MANAGEMENT RELATED
The name of the node cannot be changed if there are PVCs. The node name must be changed from the default value before adding connections, since it cannot be changed later. Use the cnfname command to change the node name.
Only one feeder trunk can be configured.
The slave end of a connection must be added first.
The slave end cannot be deleted and re-added back by itself. If you delete the slave end, the entire connection must be completely torn down and re-added back. If the slave end of the connection is deleted and re-added back by itself, then unpredictable results will happen.
For user connections, VCI 3 and VCI 4 on every VPI are reserved for VPC OAMs.
The actual number of feeder connections you can provision on the PXM is always two less than you have configured. One connection is used for LMI and another one for IP relay.
There is no error handling detection while provisioning through the CLI. Invalid endpoints and unsupported connection types (such as connections between FRSM-CESM ports or connections between structured and unstructured connections) are permitted using the CLI. The user should not configure these connections.
The sum of CIR of all channels of a port can be greater than port speed as long as CAC is disabled. However, it is not acceptable for one channel's CIR to be greater then port speed even if CAC is disabled. Two channels added up can exceed port speed. This means you cannot oversubscribe a port if only one channel is configured.
When trying to add a port on DS0 slot 32 of a CESM-8E1 line using an SNMP set or the CiscoView Equipment Manager, the SNMP agent in CESM will time out, without adding the port.The SNMP libraries treat the 32 bit DS0 slotmap (cesPortDs0ConfigBitMap) as an integer. The value for the last DS0 is treated as the sign value. This causes a corruption in the packet coming to the agent. As the agent does not receive a complete SNMP packet, it does not respond and times out. Use the command line interface to add a port on DS0 slot 32 of a CESM-8E1 line.
The cnfport command does not allow VPI ranges to be reduced. The cnfport command only allows the VPI range to expand. The correct sequence is to delete all connections on the partitions, delete the partitions, delete the port and add the port with new VPI range.
SLIP is supported on the maintenance port, but there is no PPP support on the maintenance port.
1. SES Feeder for IGX Software Interoperability with other Products
SES feeder for IGX Platform Software: PXM 1.1.12
MGX 8220 Firmware: Rev: 4.1.19 (Refer to the MGX 8220 Release Notes)
Compatible Switch Software: SwSw 9.2.23 for IGX and UXM firmware - ABE (Refer to the SwSw 9.2.23 Release Notes)
Network Management Software: CWM 9.2.05
(Refer to the CWM 9.2.05 Release Notes)
Cisco View: CV 4.2 WAN CV 2.04
(Refer to the CWM 9.2.05 Release Notes)
2. Software Boot and Runtime Firmware Requirements
| Board Pair | Boot Code | Version | Firmware | Tested Version | Minimum Version |
|---|---|---|---|---|---|
SES-PXM | pxm_sc_bkup_1.1.12.fw | 1.1.12 | pxm_sc_1.1.12.fw | 1.1.12 | 1.1.11 |
SES-PXM-4-155 | pxm_sc_bkup_1.1.12.fw | 1.1.12 | pxm_sc_1.1.12.fw | 1.1.12 | 1.1.11 |
AX-CESM-8E1 | cesm_8t1e1_CE8_BT_1.0.01.fw | 1.0.01 | cesm_8t1e1_10.0.05.fw | 10.0.05 | 10.0.04 |
AX-CESM-8T1 | cesm_8t1e1_CE8_BT_1.0.01.fw | 1.0.01 | cesm_8t1e1_10.0.05.fw | 10.0.05 | 10.0.04 |
MGX-AUSM-8E1/B | ausm_8t1e1_AU8_BT_1.0.01.fw | 1.0.01 | ausm_8t1e1_10.0.05.fw | 10.0.05 | 10.0.04 |
MGX-AUSM-8T1/B | ausm_8t1e1_AU8_BT_1.0.01.fw | 1.0.01 | ausm_8t1e1_10.0.05.fw | 10.0.05 | 10.0.04 |
AX-FRSM-8E1 | frsm_8t1e1_FR8_BT_1.0.01.fw | 1.0.01 | frsm_8t1e1_10.0.05.fw | 10.0.05 | 10.0.04 |
AX-FRSM-8E1-C | frsm_8t1e1_FR8_BT_1.0.01.fw | 1.0.01 | frsm_8t1e1_10.0.05.fw | 10.0.05 | 10.0.04 |
AX-FRSM-8T1 | frsm_8t1e1_FR8_BT_1.0.01.fw | 1.0.01 | frsm_8t1e1_10.0.05.fw | 10.0.05 | 10.0.04 |
AX-FRSM-8T1-C | frsm_8t1e1_FR8_BT_1.0.01.fw | 1.0.01 | frsm_8t1e1_10.0.05.fw | 10.0.05 | 10.0.04 |
MGX-FRSM-HS2 | frsm_vhs_VHS_BT_1.0.01.fw | 1.0.01 | frsm_vhs_10.0.05.fw | 10.0.05 | 10.0.04 |
MGX-FRSM-2CT3 | frsm_vhs_VHS_BT_1.0.01.fw | 1.0.01 | frsm_vhs_10.0.05.fw | 10.0.05 | 10.0.04 |
MGX-FRSM-2T3E3 | frsm_vhs_VHS_BT_1.0.01.fw | 1.0.01 | frsm_vhs_10.0.05.fw | 10.0.05 | 10.0.04 |
For this release the image will be pre installed as 1.1.12. All customers will only need to use these PXM installation procedures to upgrade to future maintenance releases.
Step 1 Download the 1.1.12 PXM runtime image to the PXM.
tftp <node_name or IP address> bin put pxm_sc_1.1.12.fw POPEYE@PXM_ACTIVE.FW quit
Step 2 Download the ComMat.dat file to the C:/ directory of the Active PXM. Use the tftp put command:
tftp <node_name or IP address>
bin
put ComMat.dat
Step 3 Copy the ComMat.dat file to the C:/FW directory of the Active PXM.
cp /FW quit
Step 4 Execute the install 1.1.12 command.
Step 5 Answer Yes to the question the install command will ask.
Step 1 Verify that one PXM is Active and the other Standby.
Step 2 Download the 1.1.12 PXM runtime image to the Active PXM.
Step 3 Download the ComMat.dat file to the C:/ directory of the Active PXM.
Step 4 Copy the ComMat.dat file to the C:/FW directory of the Active PXM.
Step 5 On the Active PXM, execute the command "install 1.1.12".
[The cards will reset at this point, and it is not determinate which card will become the Active and which will become the Standby.]
Step 6 After the Standby card is reset and successfully enters the hold state, on the Active PXM, execute the command "newrev 1.1.12".
Step 7 After the Active PXM is reset and successfully enters the hold state, on the Active PXM, execute the command "commit 1.1.12".
Step 1 Download the PXM backup image to the PXM.
tftp <node_name or IP address> bin put pxm_sc_bkup_<revision>.fw POPEYE@PXM.BT quit
Step 2 While in the same directory that you downloaded the backup boot file to, execute the downloadflash command.
or
While in the same directory that you downloaded the backup boot file to, execute the command install bt 1.1.12.
Step 3 Answer Yes to the question the install command will ask.
The following is the list of known anomalies in the SES feeder for IGX, release 1.1.12 delivery. Included with each is a brief discussion of the problem. A more in depth discussion is available in the release note enclosure of the problem record in Bug Navigator
| Bug ID | Description |
|---|---|
CSCdk71643 | Symptom/Condition: This is suppose to be an added feature that gives robust end to end connectivity with full recovery in cases of error. But unfortunately, with the current design it will take some extra effort and time to provide this. It will be part of future enhancement and may be available in the next release. Just a little note about why, any Traps sent to PAR are directed by LCN number which is not available without a complete end to end connection, which currently limits the generation of Traps for incomplete connections (after a stipulated timeout period). For now, due to absence of these traps a little more responsibility goes to the end user who is creating end to end connections. It is important that if and when a connection is added or removed both Master and Slave end of the connection should be added or removed respectively. Only one side of a connection should not be removed to create a new connection with the other side. Hence creating and deleting connections under any circumstance is complete only with the creation and deletion of both end of the connections. Failure to do this can result in unneeded dangling connections. |
CSCdk86638 | Symptom: When using CWM to add connections, if the connection addition request times out, subsequent addition of the same connection may fail as well, complaining that the connection already exists (even though it timed out). Description: This is caused by two factors: 1. CWM assumes that when time out, connections are not added on the switch on which the timeout occurs, and thereby only removes other segments of the timed out connection on other involved nodes. 2. On MGX switch, when CWM reports connection timeout, it does not necessarily mean a timeout on the switch. The CWM timeout may be caused, for example, by the network delay etc. from switch and CWM. The connection may actually be provisioned on the switch. Workaround: Don't use the same VPI/VCI/DLCI used by the timed out connections. This can be fixed by CWM to perform a retrieval to check if the connection is actually provisioned or not on the switch, after connection addition times out. |
CSCdm05358 | Symptom: When modifying a particular protected memory address on CESM8p which causes CESM HW watchdog reset, PXM got reset or lost SAR functionality. Description: When this happens, CESM sent a huge amount of traffic onto the management connection which is supposed to be used for intercard communication activities such as polling. This traffic causes the SAR to spend all its resources on doing the cleaning/flushing in ISR (interrupt service). This address should never be modified using the shellConn 'modify' command. It was used unknowingly in debug/test process. Workaround: Don't try to modify this protected address in shellConn (m 0xb300060) (0xb300060 is ATMizer CPU address for SAR on CESM8P). As a general guideline, shellConn commands like 'modify memory' should not be used by the customer. |
CSCdm10722 | Symptom/Condition: The install, newrev and commit commands for service module upgrade (there is no concept of downgrade here, as there exits only one valid, service module image on the disk at a time), do not follow, the same state machine as PXM commands in the current release. Hence, it is mandatory, that for service modules, these commands are given in the documented order, which is: (1) install (2) newrev (3) commit WARNING: If these, commands are not given in the above specified order, we can be in a situation where we can have two different images running on the primary/secondary combination. However, on the disk, there is only one valid image for the service modules. Workaround: Assuming, that these commands were given out of order, and now we have two different images, running, on primary / secondary combination. f1 - Old image version f2 - Newly downloaded image (1) Reset the secondary card, so that it comes up, with f2. (2) Do a softswitch between the two cards, so that secondary takes over and becomes active. At the same time, primary is reset, and comes up with f2. (3) If you may, you can now, do a softswitch, to revert back to the original primary, to restore normal state. |
CSCdm12929 | Symptom: FRSM-2CT3 card throughput drops as frame size drops below 144 octets. Conditions: Currently FRSM-2CT3 has some system limitations when the frame size is less than 144 bytes. We will improve this to some extent in the next release. Workaround: There is no work-around for this. |
CSCdm17478 | Symptom: This bug is a cell spacing/rate issue of the traffic being pumped. It's under analysis still. Workaround: The work around is to increase the IBS to 100 so that no drops are seen. |
CSCdm19747 | Conditions: cnfrscprtn and change VPI range to: VPI min =0, VPI max =0 This will lead to deleting connections that VPI is not 0. Symptoms: swerr 20909, swerr 20182, swerr 21501, swerr 20320 Work Around: If there are many connections on the feeder trunk, don't change the VPI range to smaller value than the connections' VPI. The cnfrscprtn should be blocked at the source if there are conns on the interface. |
CSCdm22510 | Symptom: Connection traps are not sent out when receiving A bit update from CPE. Conditions: The end result of this is that CWM will not be notified about the channel status change (failure or normal), neither will PXM/PAR. The remote end is notified via in band OAM. This applies to all service modules. Workaround: No Workaround |
CSCdm23426 | Symptom: Config change trap carries the port resource partition row status as ADD while deleting the resource partition. Conditions: Wrong status will be sent with all resource partition DEL traps. Workaround: Currently there is no work around to avoid database inconsistency between CWM and the service module. |
CSCdm28951 | Symptom: PXM having wrong A-bit status Conditions: Unknown. Workaround: There is no work-around for this. |
CSCdm30541 | Symptom: cnfrscprtn fails to configure given VCI range. Description: Only one dimensional resource partitioning, either VPI or VCI resource partitioning is available. If resource partitioning is attempted for both VPI & VCI, only VPI partitioning will take affect (if possible). The VCIs will be given full range for every controller. The command will not return error. VCI partitioning is only possible if the port is configured with only ONE VPI value instead of a range. Workaround: To use VCI partitioning, configure only ONE VPI value instead of a range. |
CSCdm33677 | Symptom: Not able to add ABR1 connection from PXMUNI to PXMUNI (3-segment) whenever the feeder trunk has some of its bandwidth used up due to other connections. Condition: Using SV+ to add ABR1 connection. The SCR field is default to the max port bandwidth and not editable (greyed out). If there is at least one other connection already added, the available bandwidth will be less than that of the port speed.The new connection addition will fail. Workaround: Use CLI to add connection (addcon) then modify the SCR to the desired value (within what is available) via cnfupcabr (another CLI command). |
CSCdm40113 | Symptom: It takes over 20 minutes for the FRSM-2CT3 cards to go active after a clrallcnf command has been issued. Conditions: Occurs when there are several FRSM-2CT3s in the shelf along with other service modules. Workaround: None. Wait for cards to go active. Further Problem Description: Creation of default service module config takes a long time and is processed one service module at a time. Subsequently, all the other SM wait to go active until the default config upload for all the service modules are done. |
CSCdm44173 | Symptom: Negative test failure. Changing the DC type results in connection being lost. Conditions: Changing the daughter card type (e.g oc3 to t3 or vice-versa) results in the PXM connections to be lost. This is due to the restore failure on a different physical interface type. Once the type of the daughter card is changed, the line driver will not add the line due to a different card type. However, the higher modules (PAR, VSI) etc. must have a mechanism in case of a restore failure and the should not result in connection deletion. Workaround: There is currently no workaround for this. |
CSCdm44523 | Symptom: bootChange inputs must include host name, or inet on ethernet field will go into the host name and file name fields as shown below -> bootChange
'.' = clear field; '-' = go to previous field; ^D = quit
boot device : lnPci
processor number : 0
host name : e=172.16.156.29
file name : ffffff00
inet on ethernet (e) :
inet on backplane (b):
host inet (h) :
gateway inet (g) : 172.16.156.1
user (u) :
ftp password (pw) (blank = use rsh):
flags (f) : 0x0
target name (tn) :
startup script (s) :
other (o)
:
Conditions: Occurs when executing the bootChange command, and nothing is entered in the host name field Workaround: Be sure to put something into the host name field, and this problem will not be seen |
CSCdm45141 | Symptom: Switchcc displays ssiFrameXmt failed and VSI master: invalid sw clock info pg Condition: The ssiXmtFrame failure was caused by SCM transmitting on GLCN=0, which is reserved. This is due to scmSwitch including slot 31 and slot 32 which are not mapped in SCM master. switchcc on PXM displays the following message in the PXM log: 1. ssiFrameXmt failed, error status -1 - 31 dropped 2. Vsi master: invalid sw clock info pg ; 2, 3, -2104681808 - 1 dropped 05/27/1999-06:16:13 07 PAR:Vsi PAR-7-VSIM_DEBUG Vsi master: invalid sw clock info pg ; 2, 3, -2104681808 - 1 dropped 05/27/1999-06:16:10 07 PAR:Vsi PAR-7-VSIM_DEBUG Vsi master: invalid sw clock info pg ; 2, 3, -2104681808
Workaround: No Workaround |
CSCdm46245 | Symptom: LED alarm light displays but dspalms shows no alarms. Condition: This intermittent condition occurs where Major Alarm red LED light displays while there is no actual alarm(s). CLI command "dspcds" shows Major shelfIntegratedAlarm, but dspcd (on service module) or dspalms shows all clear. This problem/condition is under investigation. Workaround: None. |
CSCdm46394 | Symptom: SYSTEM ERROR 20208 occurred during SM images upgrading to 10.0.02_01Jun99_1 Condition: This is a one time occurrence. The following is observed: ################################### ###### SYSTEM ERROR 20208 1 1179649 1 1179649 ###################################
Description: The above error indicates that PAR is receiving bulk interface trap before the interfaces known to PAR, so PAR is logging the bad interface system error. This is a rare race condition. Subsequently when the individual port trap comes, the interface will be created in PAR properly. Workaround: No workaround. This error is not causing any problem as the port state will be updated correctly subsequently by the individual port trap. |
CSCdm47203 | Symptoms: In rare cases, adding huge amount of connections may cause FRSM-VHS SMs to slow down on "cc" responses. Conditions: The FRSM-VHS SMs may show warning messages on the console reporting "no more SCM buffers" or "no more session available". In some cases, the FRSM-VHS just simply not responding, or very slow on the console. Workaround: Increase timeout value for the "cc" command: > shellConn
-> cliCcTimeout = 60
. Reset the service module. . There will be a fix to increase number of SCM buffers for FRSM-VHS service modules. |
CSCdm49090 | Symptoms: FRSM-VHS card fails to go to Active state during the upgrade process. It also fails to log any message. Conditions: This occurs when FRSM-VHS card has 16 MB DRAM and the firmware upgrade process (to firmware supporting 2000/4000 connections) is done. Work Around: User has to upgrade the hardware from 16MB to 32MB DRAM. |
CSCdm49862
| Symptom: dspln fails, returning "undefined symbol" mgx1.1.3.VHS2E3.a > dspln 1
undefined symbol: dspln
mgx1.1.3.VHS2E3.a > dsp
Unknown Command : dsp
The possibilities are :
dspalm dspalmcnf dspalmcnt
dspalms dspbufoverflow dspcd
dspcderrs dspcdprtntype dspcdrscprtn
dspchan dspchancnt dspchanmap
dspchans dspchstats dspcon
dspcons dspds3ln dspds3lns
dspdsx3bert dspegrq dspegrqs
dspfeature dspfst dsplcn
dspln dsplns dspmaptbl
dspmsgcnt dspport dspportcnt
dspportrscprtn dspports dspportstats
dspsarcnt dspsarcnts dspservrate
dspslftst dspslftsttbl dspstatparms
dspsvcrange dsptaskinfo dsptotals
dspusedlnmap
mgx1.1.3.VHS2E3.a > version
***** Cisco System. AXIS FRSM-VHS Card *****
Firmware Version = 10.0.01
Backup Boot version = 5.0.00_15Dec98
VxWorks (for CISCO) version 5.3.1.
Kernel: WIND version 2.5.
Made on Sat May 8 00:43:44 PDT 1999.
Workaround: No workaround |
CSCdm51382 | Symptom: FRSM-card takes about 1 minute to report A=0 to CPE, when line goes into alarm. Conditions: The conditions when this will occur is unknown. Still investigating the problem. Workaround: There is no workaround. |
CSCdm51406 | Symptom: The remote end card does not receive any OAM cells. Conditions: This happens when the local end card continuously sends OAM cells over a long period of time. Work Around: The local end card has to be reset so that it will start transmitting OAM cells. |
CSCdm52380 | Symptom: After an ungraceful upgrade, the PXMs end up in boot state. Conditions: An ungraceful upgrade using setPXMPrimary is done. Workaround: Reset the PXMs after the problem occurs. |
CSCdm52590 | Symptom: This occurs when a PXM is reset during an upgrade/downgrade operation (other than the reset performed as part of the operation). Work Around: Nothing, the PXM eventually gets to the correct state. It just takes a while. |
CSCdm54916 | Symptom: cesm-t1 with UNI connections start showing AIS-OAM cell incrementing. This can be seen using dspchancnt. However, no traffic loss has been observed because of these AIS cell increment. Condition: This problem is intermittent. Work Around: There is currently no work around for this. |
CSCdm56094 | Symptom The far end device can not be put into a loopback using the "Far End Inband Loopback" or the "Far End ESF Loopback" options under the "DEVICE TO LOOP" menu in the "cnfbert" command. If these options are chosen as part of a BERT pattern test, then the test will not be configured as it will fail to sync the pattern. Condition The inband and ESF loopbacks are activated/de-activated by transmitting the loopback codes for the minimum number of seconds specified by the ANSI T1.403 specification. However, due to variations in the way time is measured by the AUSM and the far-end devices, some devices do not detect the code for the desired number of seconds and hence they do not activate/deactivate the loopback. Workaround This problem may not be seen on all (far-end) devices. If it is seen, then there is no workaround other than trying to repeat the test configuration till it is successful. |
CSCdm57683 | Symptom: The dsplns command will display a line as disabled, but you cannot do an addln. Conditions: User runs the following sequence of commands: saveallcnf restoreallcnf install newrev commit Workaround: Do not execute the restoreallcnf command before executing the install command. |
CSCdm57795 | Symptom: Illegal LCN error message Conditions: When performing a switchcc, the following error popped up repeatedly. This was observed 3-4 times during DevTest. rmLcnBlkGet:illegal lcn number:lcn = 0 if = 0x 0 max_lcn = 4112 firstDataLcn = 16 rmLcnBlkGet:illegal lcn number:lcn = 0 if = 0x 0 max_lcn = 4112 firstDataLcn = 16 rmLcnBlkGet:illegal lcn number:lcn = 0 if = 0x 0 max_lcn = 4112 firstDataLcn = 16 rmLcnBlkGet:illegal lcn number:lcn = 0 if = 0x 0 max_lcn = 4112 firstDataLcn = 16 Description: This error message indicates that a connection with an illegal LCN (in this case it is LCN=0) is being resynced. It is found that this is not causing any problem on the switchcc, but may delay the the standby PXM up to 1 minute to go to active. Workaround: No workaround. |
CSCdp03640 | Symptom: The dspshelf command shows fans for the SES feeder for IGX that are not an option for the SES feeder for IGX. Workaround: No workaround. |
CSCdp27092 | Symptom: The SES feeder for IGX does not support the 42 MHz clock on the cell bus. The cnfcbclk, dspcbclk, xcnfcbclk, xdspcbclk commands do not work if executed on the SES feeder for IGX platform. This is due to the fact that the cell bus mapping to slot assignment is not done correctly for the SES feeder for IGX platform. Workaround: No workaround. Use the 21 MHz clock. |
For service and support for a product purchased from a reseller, contact the reseller. Resellers offer a wide variety of Cisco service and support programs, which are described in the section "Service and Support" in the information packet that shipped with your chassis.
For service and support for a product purchased directly from Cisco, use CCO.
Cisco Connection On-line (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.

![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Dec 20 14:24:55 PST 1999
Copyright 1989-1999©Cisco Systems Inc.