Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar, select Documentation, and click Enter the feedback form. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.
The 9.2 software release supports the Cisco WAN switching products, BPX 8600 series, and IGX 8400 series. This release does not support the IPX switch.
The MSSBU rollout plans for the 9.2 release is based upon a series of incremental feature releases. This phased feature release strategy is designed to allow the earliest customer availability of key new features, consistent with maintaining high product quality. For the latest status of each 9.2 feature, please see below.
The minimum release version noted in the table below represents the minimum switch software version required for each feature. As usual, it is recommended that customers use the most current maintenance releases.
Generally Available (GA)--Feature is ready for wide deployment with no restrictions. Customers deploying GA features are supported by the Technical Assistance Center (TAC).
First Customer Ship (FCS)--Feature is available for controlled introduction by selected customers. To trial use an FCS feature, please contact your account representative.
Customers selected for controlled introduction will receive assistance with test plan review and special support from the New Product Team (NPT) in addition to the normal Technical Assistance Center (TAC) support.
Pre-First Customer Ship (Pre-FCS)--Feature is not yet available in the Switch Software baseline.
Target Date--This is the date for feature delivery that is supported by current Engineering and Marketing plans. This date is subject to change.
Product | Feature Name | FCS/GA Status | Minimum Release |
|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This is a maintenance release including all features supported up to Release 9.2.30. The following files will be extracted from a TAR file upon upgrading to Software Release 9.2.34.
| File Name | File Size |
|---|---|
9234B.000 | 65536 |
9234B.001 | 65536 |
9234B.002 | 65536 |
9234B.003 | 65536 |
9234B.004 | 65536 |
9234B.005 | 65536 |
9234B.006 | 65536 |
9234B.007 | 65536 |
9234B.008 | 65536 |
9234B.009 | 65536 |
9234B.010 | 65536 |
9234B.011 | 65536 |
9234B.012 | 65536 |
9234B.013 | 65536 |
9234B.014 | 65536 |
9234B.015 | 65536 |
9234B.016 | 65536 |
9234B.017 | 65536 |
9234B.018 | 65536 |
9234B.019 | 65536 |
9234B.020 | 65536 |
9234B.021 | 65536 |
9234B.022 | 65536 |
9234B.023 | 65536 |
9234B.024 | 36752 |
9234B.img | 784 |
9234G.000 | 65536 |
9234G.001 | 65536 |
9234G.002 | 65536 |
9234G.003 | 65536 |
9234G.004 | 65536 |
9234G.005 | 65536 |
9234G.006 | 65536 |
9234G.007 | 65536 |
9234G.008 | 65536 |
9234G.009 | 65536 |
9234G.010 | 65536 |
9234G.011 | 65536 |
9234G.012 | 65536 |
9234G.013 | 65536 |
9234G.014 | 65536 |
9234G.015 | 65536 |
9234G.016 | 65536 |
9234G.017 | 65536 |
9234G.018 | 65536 |
9234G.019 | 65536 |
9234G.020 | 65536 |
9234G.021 | 65536 |
9234G.022 | 65536 |
9234G.023 | 65536 |
9234G.024 | 65536 |
9234G.025 | 65536 |
9234G.026 | 52206 |
9234G.img | 784 |
This is a maintenance release including all features supported up to Release 9.2.30.
Includes all features supported up to Release 9.2.20 and introduces the following additional features:
Includes all features supported up to Release 9.2.20.
Includes all features supported up to Release 9.2.10 and introduces the following additional features:
Includes all features supported up to Release 9.2.01 and introduces the following additional features:
Includes all features supported in Release 9.2.00 and introducing the following additional features:
Introduces the following features:
1. Release 9.2.31 introduced a new command--cnffdrlmiparms--which makes the feeder LMI timers and counters configurable. This command is currently supported on BPX only and cannot be added in the Job mode.
Timer | Description | Range (sec.) | Default (sec.) |
|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2. In Release 9.2.31 the system parameter 2 (cnfsysparm 2) is changed from "Fail Connections On Communication Break" to "Allow CPU Starvation of Fail Handler."
3. Do not mix MEE and MEF (or higher) in Y-red pairs for BXM 2-port group enhanced cards (OC-3 or OC-12 port). Addyred will fail if both are in standby mode, or the primary card has been activated with MEF (or higher) and the secondary card has MEE.
4. For the BXM 2-port group, enhanced cards activated with MEF or higher, downrev to MEE will bring the cards into MISMATCH mode. This applies to both single cards and Y-red pairs.
5. Release 9.2.30 introduced four new commands in BPX:
6. There are changes in the following command starting from Release 9.2.30:
7. The multiple partitions introduce two VSI partitions on trunk and port interfaces on the BXM card. One partition can be used for MPLS, and one can be used for PNNI. Virtual Trunk can have only one VSI partition or can be used for AutoRoute, but cannot be used for both VSI and AutoRoute simultaneously. This project introduces six service class templates in addition to the three existing templates.
8. There is a change in reporting of port group numbers in Release 9.2.32. Previous image (MEC) of BXM used to report a 1-port group for the 2-port group cards at the channel statistics level 2 and 3. This made the port belonging to second port group unusable.
9. In BPX nodes that use processor cards with 32 MB of RAM, it is possible to run out of memory in the Hitless Region. This can happen if the node is too heavily configured with cards and connections. The recommendation below should prevent memory aborts.
17100 blocks for card database
1500 blocks for EACH BXM that supports 16K conns
3000 blocks for EACH BXM that supports 32K conns
300 blocks for EACH 1000 conns
-----------------------------------------------------------------
40000 blocks maximum total (34000 blocks for 9.2 releases up to 9.2.23)
10. The minimum software required to run MPLS are:
11. The 16K connections feature increases the number of connections terminating on the BPX switch to 16,000. The count includes connections terminating on BXM or ASI endpoints on cards within the node as well as connections terminating on service modules in the feeder shelves connected to the BPX switch. For example, a Frame Relay connection that originates on an FRSM in an MGX 8220 connected to a BPX counts as one of the 16,000 terminated connections on that BPX.
12. Version 2.2 of the Virtual Switch Interface (VSI) provides the BPX switch with the ability to support multiple network protocols and multiple controllers per switch (for example, MPLS, PNNI, and so on). Switch resources can be dedicated to a specific controller or shared by multiple controllers.
13. The combinations of system limits such as the number of trunks, lines, ports, and connections as well as enabled TFTP interval statistics should be provisioned so that the node has at least 50 percent idle time usage. Use the command dspprfhist to verify.
14. When cost-based routing is used, increasing the cost of a trunk will result in deleting the preferred path on connections in the database if the sum of the preferred path cost exceeds the connection of configured cost. The connections will remain routed on its current path.
15. On the BXM and UXM, for the OC-3 MultiMode Fiber back cards, Y-Redundancy/hot standby is not supported due to hardware restrictions.
16. The trunk reconfiguration feature does not support IMA trunks.
17. HDM to UVM interworking for Nx64K connections is not supported in this release.
Please consult your Support Representative before performing any software upgrade.
1. The earliest release supported for graceful upgrade is 9.1.03.
2. The 9.2 switch software requires MEH or MFD BXM firmware.
3. Before upgrading to this release when UXM cards are to be used, certain legacy card firmware must be upgraded. See the compatibility matrix for cards affected and the exact versions to be used.
![]() |
Note Standards-compliant IMA is not compatible with the proprietary IMA protocol used in revision A firmware. Both ends of an IMA trunk must have the same protocol. |
![]() |
Caution Failure to follow this procedure may result in the card not operating. The card should be returned to Cisco if this occurs: |
In order to run Model B firmware on UXM, the card needs to be running boot code revision 6 or greater. To determine the boot code running on the card, issue the following command from CLI (user must be logged in as Service level or greater to use this command):
rsh <slot #> sys version
Step 2 Upgrade UXM's boot code if necessary
The process for loading boot code is identical to the process you would use to load firmware. The only part that changes is the name of the file.
![]() |
Note Burning the boot code will cause the card to reset. |
Step 3 Upgrade UXM's firmware
Step 4 When Y-redundant trunks are used, the red alarm in/out values must be configured to 1.25/1.5 seconds or greater, or else INVMUX failures will occur and trunk failures will be observed during a Y-redundancy switchover. Use the following command:
cnftrkparm
This is due to the IMA protocol and may cause reroute of connections.
Step 5 Upgrade NPM software to 9.2
4. Procedure for upgrading UXM-to-IMATM trunks from proprietary IMA protocol to ATM forum-compliant IMA protocol.
Step 2 On IGX, to have firmware upgrade, issue command cnffunc 15 d to disable the UXM from resetting automatically after the firmware is burned in.
Step 3 On each MGX 8220 equipped with IMATM-B, upgrade the ASC to 5.0.10.
Step 4 Download the Forum Compliant Firmware Version IMATM5.0.10.fw but do NOT reset the IMATM-B card.
Step 5 On each IGX-UXM with IMA to be upgraded, burn firmware ABE or later to each UXM with IMA trunks.
Step 6 Simultaneously reset the card at each end of each IMA trunk to minimize trunk outage.
Step 7 Upgrade 9.1 nodes to 9.2 via loadrev and runrev.
Step 8 Issue the command cnffunc 15 e after each IGX is upgraded to 9.2.20 or later.
![]() |
Note The above procedure also applies to the UXME. |
5. Procedure for upgrading UXM-to-UXM trunks from proprietary IMA protocol to ATM forum-compliant IMA protocol.
![]() |
Note For Y-redundant UXMs, issue the command cnftrkparm 18 100000 100000 prior to this procedure and return to default values after this procedure. |
Step 2 On IGX to have firmware upgraded, issue command cnffunc 15 d to disable the UXM from resetting automatically after the firmware is burned in.
Step 3 On each IGX-UXM with IMA to be upgraded, burn firmware ABE or later to each UXM with IMA trunks.
Step 4 Simultaneously reset the card at each end of each IMA trunk to minimize trunk outage.
Step 5 Upgrade 9.1 nodes to 9.2 via loadrev and runrev.
Step 6 Issue the command cnffunc 15 e after each IGX is upgraded to 9.2.20 or later.
![]() |
Note The above procedure also applies to the UXME. |
6. Procedure for upgrading BXM cards to the 9.2 firmware release.
To enable BXM cards to utilize 9.2 features, all BXM cards must be upgraded to the 9.2 firmware release. The following steps should be taken to avoid card mismatch:
For the switch running
Perform the following steps to avoid card mismatch:
Step 2 Upgrade BCC software to 9.2.30 or higher.
Step 3 Upgrade BXM firmware to MEH.
For all other cases, do the following steps:
Step 2 Upgrade BCC software to 9.2.30 or higher.
![]() |
Note See the Compatibility Matrix for the exact versions to be used. |
7. Procedure for adding new BCC cards as a part of upgrading to the 9.2 release.
![]() |
Note See the Compatibility Matrix for the tested/supported versions of other firmware and software that work with this release. |
Step 2 Upgrade the BXMs
All the BXM cards in the node are upgraded to Revision E, which is VSI Version 2 and CoS capable. After each BXM card is downloaded with the Revision E image, it temporarily experiences VSI outage until the BCC software is upgraded to the 9.2.34 image. The VSI outage during the upgrade is caused by the Revision E firmware not being backward compatible with VSI Version 1 features.
Note that from the TSC perspective, after a BXM is upgraded to the Revision E image, the interfaces that used to be on the card will "disappear." The TDP sessions that were on the interfaces will be lost. When all the BXMs are upgraded to the Revision E while still running Release 9.1 software on the BCC, the node will experience a complete outage of MPLS traffic. AutoRoute will have a hitless upgrade.
Step 3 Upgrade the BCC.
As the BCC is upgraded from software Release 9.1 to Release 9.2.34, the BCC recognizes the Revision E BXMs and downloads the VSI partition configuration. This causes the BXMs to issue ifc cfg traps to the TSC, allowing the TSC to rediscover all the MPLS interfaces on the BPX. The TDP sessions are reestablished and MPLS traffic starts flowing again through the BPX.
![]() |
Note The VSI 1.1 and VSI 2.2 are not interoperable. |
Revision interoperating upgrades are supported, from the 9.1 to 9.2 releases of Switch software, with secondary revision incorporation for network lowest revision. This will lessen the risk of new features being enabled in a mixed network after the downgrade.
A "Secondary Revision" field in the node is used for the determination of the network lowest revision. Previous to this change, software used only the nodes primary revision.
The interoperability functionality uses network lowest revision for:
For a complete list of firmware revisions supported, see the Compatibility Matrix document, which is included in this release package.
All processor cards must be configured with a minimum of 32MB of RAM. This includes BCCs and NPMs. NPMs require at least 1MB of BRAM. To verify the BRAM size on IGX 8400 nodes, use the dspcd command.
![]() |
Note If any control cards contain less than 32MB of DRAM (these would be NPMs) then they must be replaced with cards containing at least 32MB of DRAM prior to upgrading to Release 9.2. The physical upgrade of the nodes with these control cards must be done according to the upgrade procedure defined as follows. |
As specified next, the correct version of control card (CC) boot firmware must be installed on the cards prior to a software upgrade to Release 9.2.
BCC Type | Firmware |
|---|---|
|
|
|
|
|
|
|
|
NPM Type | Firmware |
|---|---|
|
|
|
|
|
|
|
|
With the new version of NPM boot code (RXS), the boot code upgrading does not require physical card resetting with the following steps:
Step 2 Execute the switchcc command and wait until the NPM(1) becomes standby. NPM(2) is now active.
Step 3 Execute the resetcd command to reset the standby (resetcd 1 h). Wait until the reset card NPM(1) becomes standby.
Step 4 Burn the boot code on the active NPM(2).
Step 5 Execute the switchcc command and wait until the NPM(2) becomes standby. NPM(1) is now active.
Step 6 Execute the resetcd command to reset the standby (resetcd 2 h). Wait until the reset card NPM(2) become standby.
Each redundant pair of BCC cards in a given BPX 8600 node must be of the identical type and memory configuration. That is, for example, if the active card is a BCC-3-32, then so must be the standby. BCC-3 cards with 32MB of RAM cannot be mixed with BCC-3 cards with 64MB of RAM.
Each redundant pair of NPM cards in a given IGX 8400 node must be of the identical type and memory configuration. That is, for example, if the active card is an NPM-32, then so must be the standby. NPM cards with 32MB of RAM cannot be mixed with NPM cards with 64MB of RAM. Also, NPM-64 cards cannot be mixed with NPM-64B cards.
This is a requirement for all software upgrade and downgrade procedures. It does not apply to the physical card upgrade procedure, described in the following section.
When performing a control card (CC) upgrade, the following procedure must be used. This applies to all processors: BCCs, and/or NPMs.
Step 2 Replace with new CC front and back cards. (Replace back card only apply to BCC.)
Step 3 Wait for the standby updates on the newly installed standby CC to complete.
Step 4 Issue a switchcc command to utilize the newly installed CC.
Step 5 Verify that the network is stable.
Step 6 Remove the current standby CC front and back card. (Remove back card only applies to BCC.)
Step 7 Replace with new CC front and back cards that are identical to the current active CC. (Replace back card only apply to BCC)
Step 8 Wait for the standby updates on the newly installed standby CC to complete.
Step 9 The CC physical upgrade is now complete.
Step 10 With the secondary card in the standby state, cause a switchover using the switchcc command. This will test that the hardware is working correctly.
![]() |
Note After Step 2, the node will contain a mix of an old type CCs and the new type CCs. This condition is permitted only while the standby updates to the new CC are in progress, which will take less than one hour. The time during which this mixture of CC types exists must be kept to a minimum by immediately replacing the second old type CC with the matching one of the new type. |
1. Switch Software Release 9.2 is not compatible with UXM firmware Model A.
2. If attempting to burn UXM firmware Model B into UXM firmware Model A with 9.2 software, the firmware Model B will not be burned into the UXM card due to the incompatibility of software 9.2 and UXM firmware Model A. The UXM has to be returned to Cisco for service.
3. If using MEA/MEB/MEC BXM firmware and upgrading to MED or later, the 9.2.30 or later software has to be upgraded first so that the BXM will report 2-port groups for 2-port cards all the time. The smooth transition between the earlier 1 port group and the newly reported 2-port groups also displays message in dspcd "Inconsistency with logical PG #" (port group number). All earlier software will mismatch the card. This applied to BXM-OC3 or BXM-OC12 and configured to channel statistic level 2 or higher.
4. Firmware MED and earlier supports APS Redundancy on Legacy BXM only.
5. Because of hardware limitations, BXM hardware is not able to recognize all user-programmed cell transmission rates. Rather only discrete transmission rates can be used instead.
if (configured cell rate == full line cell rate) then
transmitted cell rate = full line cell rate
else
transmitted cell rate = from equation below or from table below

1464865 | 56552 | 28832 | 19348 | 14559 | 11670 | 9738 | 8355 |
733860 | 54458 | 28278 | 19097 | 14416 | 11579 | 9674 | 8308 |
489558 | 52513 | 27744 | 18852 | 14277 | 11488 | 9611 | 8261 |
367288 | 50703 | 27231 | 18614 | 14139 | 11399 | 9549 | 8215 |
293888 | 49013 | 26736 | 18381 | 14005 | 11311 | 9487 | 8169 |
244938 | 47432 | 26258 | 18154 | 13872 | 11225 | 9426 | 8124 |
209966 | 45950 | 25798 | 17933 | 13743 | 11140 | 9366 | 8079 |
183733 | 44558 | 25353 | 17717 | 13616 | 11056 | 9307 | 8035 |
163327 | 43247 | 24923 | 17506 | 13491 | 10974 | 9248 | 7992 |
147001 | 42012 | 24508 | 17300 | 13368 | 10892 | 9190 | 7948 |
133642 | 40845 | 24106 | 17099 | 13248 | 10812 | 9133 | 7906 |
122509 | 39741 | 23717 | 16902 | 13129 | 10733 | 9077 | 7863 |
113088 | 38695 | 23341 | 16710 | 13013 | 10656 | 9021 | 7822 |
105012 | 37703 | 22976 | 16522 | 12899 | 10579 | 8966 | 7780 |
98013 | 36761 | 22623 | 16339 | 12787 | 10503 | 8912 | 7739 |
91889 | 35864 | 22280 | 16159 | 12677 | 10429 | 8858 | 7699 |
86485 | 35010 | 21947 | 15983 | 12568 | 10355 | 8805 | 7659 |
81681 | 34196 | 21625 | 15812 | 12462 | 10283 | 8753 | 7619 |
77383 | 33419 | 21311 | 15643 | 12357 | 10212 | 8701 | 7580 |
73515 | 32676 | 21007 | 15479 | 12254 | 10141 | 8650 | 7541 |
70014 | 31966 | 20711 | 15318 | 12153 | 10072 | 8599 | 7502 |
66833 | 31286 | 20423 | 15160 | 12053 | 10003 | 8549 | 7464 |
63927 | 30634 | 20143 | 15005 | 11955 | 9936 | 8500 | 7427 |
61264 | 30009 | 19871 | 14853 | 11859 | 9869 | 8451 | 7389 |
58814 | 29409 | 19606 | 14705 | 11764 | 9803 | 8403 | 7352 |
..... |
|
|
|
|
|
|
|
6. On the BPX with MGX 8220 feeder(s), regardless of the setting of the Node Parameter "42 Enable Feeder Alert," a feeder alert message will be sent to all MGX 8220 feeders immediately before a hitless rebuild takes place. The feeder alert message will temporarily disable the LMI polling from the MGX 8220 feeders. The MGX 8220 polling will resume as soon as the BPX is ready to exchange LMI messages.
7. The amount of traffic allowed on a VP tunneling connection is two-thirds bandwidth of that connection. The minimum bandwidth must be 100 cells per second. For example, a CBR connection with a peak cell rate 1500 cps then can pass traffic up to 1000 cps.
8. For IMA trunks, the configuration is blocked if the converted cps of the number of links to be decremented is MORE than the transmit rate (CSCdm71616).
1. For Switch Software 9.2, MPLS and PNNI controllers cannot coexist.
2. In Release 9.2.30 and later, nodes might declare a communication break when using the BXM virtual trunking feature. The problem has been observed under the following conditions:
3. When the cnfrsrc command is used to delete VSI partitions on an interface, software does not check if any Soft Permanent Virtual Circuit (SPVC) connections exists on that partition. Even if there are SPVC connections on a partition, the partition can be deleted using the cnfrsrc command. The only protection is that users are provided with a warning when they try to delete the partition.
4. Switch Software 9.2.30 or later and BXM firmware MFC and later support the attachment of multiple MPLS controllers.
5. For UVM cards, there will be no new revisions of Model A firmware. When attempting to download Model A firmware to a UVM, software will give the user an error message indicating that the firmware does not match the card type. Note that there is no problem with continuing to use existing UVM cards running the old firmware(CSCdp08741).
6. For a virtual trunk on a BXM/UXM, the Transmit Trunk Rate (the transmit rate of the virtual trunk) is configurable to match the PCR value of the subscribed public VPC service. In this release, the actual shaping rate for a virtual trunk is higher than the configured Transmit Trunk Rate (CSCdm80482). The actual virtual trunk shaping rates are 1/(n x 680 x 10-9) cells per second, where n is an integer from 1 to 29,411. In this release, the user-configured Transmit Trunk Rate is rounded to the next higher (as opposed to lower) actual shaping rate for shaping.
Step 2 Configure the Transmit Trunk Rate for the virtual trunk to be less than 1/(n x 680 x 10-9) cps but greater than 1/((n+1) x 680 x 10-9) cps. For example, if the PCR value of the subscribed public VPC service is 10 Mbps or 23,585 cps, configure the Transmit Trunk Rate for the virtual trunk to be less than 1/(63 x 680 x 10-9) = 23,342.67 cps but greater than 1/(64 x 680 x 10-9) = 22,977.94 cps.
7. There is a new traffic class added in Release 9.2.20 that causes a trunk parameter conflict with pre-9.2.20 node. The conflict fails adding trunk between 9.2.20 BTM/ATM and pre- 9.2.20 BTM/ATM.
8. The cloud port to which a virtual trunk is connected should have ILMI polling disabled. Otherwise, it could lead to a virtual trunk being clear on one end and declaring Virtual Trunk Path Failure at the other end (CSCdm52909).
9. In a BPX that contains BCC cards with 64MB, there is no limitation. All 12 available slots can contain BXM or Enhanced-BXM cards.
10. For performance reasons, AIS status of connections is not sent to the standby BCC. After switchcc, it may take a few minutes to update the AIS status of connections. If dspcon does not show the proper status of AIS or the dspalms screen shows an incorrect number of AIS, (after switchcc) wait for few minutes so that the status gets updated. (The dspalms and dspcon commands show the status of AIS.)
11. Hitless rebuild has similar limitations to that of a switchcc and full rebuild:
12. UVM cards in Y-redundancy will mismatch if one is burned with Idle Code Suppression Firmware and the other is not.
13. Mismatch is reported when replacing a BXM card with another BXM card that has a different port group, even though both BXM cards have the identical channel number.
14. When upgrading from Release 9.1 to 9.2, the 9.1 statistics on BXM/UXM cards are supported to maintain compatibility. However, once a user configures a statistics level in 9.2, the statistics cannot be configured back to 9.1 statistics.
15. The BXM and UXM channel statistics level feature gives these cards the capability of collecting more than four statistics per connection. However, it is the controller card's limitations, available memory, and performance, that indicates how many statistics can actually be collected from the cards and then reported to the Cisco Wan Manager (CWM).
16. In Release 9.1, the UXM card ran a proprietary IMA communication protocol. This protocol matched that used on the MGX 8220 4 IMATM-B cards and hence could be connected together to form a trunk. In Release 9.2, we now support standards-compliant IMA on the UXM card. The standards-compliant IMATM-B on MGX 8220 5.0 is not yet released. Hence, when the network is upgraded to 9.2., the UXM will be running compliant IMA protocol and the IMATM-B will still be running the proprietary IMA communication protocol. They will no longer communicate and the trunk will fail. This will be fixed in the MGX 8220 5.0 release containing IMATM-B. However, it should be noted that an upgrade at that time will also incur some amount of downtime as there will be a difference in timing between the MGX 8220 upgrade and the switch software upgrade. There should be no effect to UXM-IMA trunks connected to other UXM-IMA trunks in 9.1 to 9.2 interoperability mode.
17. The transmit rate on an IGX IMA trunk can be altered at the local node with any trunk outage. It is possible that the transmit rates are different at the two ends of an IMA trunk. After this trunk is deleted, it cannot be added back unless the transmit rates are the same.
18. When doing a grouped upgrade from Release 9.1 to 9.2, the software error 1427 may be logged on the BPX/IGX node during a non-graceful upgrade. This error can be ignored since it is harmless to the network (CSCdm14613).
19. Reconfiguring trunk parameters might cause connections to be rerouted if the changed bandwidth load is smaller than what was used by the connections that use the trunk.
20. If LMI/ILMI is provided by the BCC:
21. Virtual Path Connections with cells whose VCI values are above 4095 will be transmitted correctly only if the path is exclusively through BXM trunks and terminate at BXM ports.
22. The feature of CIR=0 for Frame Relay connections is not supported for connections terminating between FRM cards in IGX nodes and FRSM cards in an MGX 8220 shelf.
23. SVC connections are derouted after decreasing the allocated bandwidth (increasing Statistic Reserve). It is the design intent that increasing the statistical reserve will cause SVC conns to derouted and not be rerouted (CSCst92308).
24. For the loadrev operation, it is important that the Cisco Wan Manager/TFTP buffers are maintained at their default size.
25. Due to a hardware limitation, the BNI trunk will send 13-15 percent more traffic than what it is configured for when the trunk is configured for less speed (cps) than the maximum port speed. This is especially important when the BNI trunk is connected to IMATM pairs, which carry less than T3 bandwidth.
26. When using the shift/no-shift feature on a BPX 8600 node's port card, controlled via the cnfport command, the other end of the connection must have the same setting. Otherwise, there will be a loss of continuity.
27. When deleting trunks, there is a known limitation with the switch software. The deltrk command should always be executed on the node that remains as part of the network, rather than from the node that ends up being removed from the network. This is to ensure that all the necessary updates are sent to the rest of the network (CSCdi85134). Also if the command is not used as recommended here, a software error 419 could occur (CSCdi91285).
28. Due to trunk-based loading, any commands having to do with trunk loading and the load model (dspload chklm dsplm, and so on.) need to be done only after waiting a certain period of time. This time is a direct function of the trunk load update interval time (as configurable) plus the conditional update latency time.
29. The external ABR segment control loop on ForeSight (ABRFST) is an option at the user interface. It is supported by UXM-E/BXM-E but is not supported by UXM/BXM hardware. The user should not enable this option on ForeSight connections (CSCdi92451). In any case, there is no coupling between the loops.
30. On a heavily loaded BPX 8600 node, during connection rerouting, the status of a particular connection is indicated as OK even though the line status of the other end of the connection is listed as failed. The connection is in fact OK, because the conditioning of the connection (to update the status for both ends) is done by a low-priority process so that the rerouting of the connections can be given high priority. The status will be eventually updated. (CSCdj10762)
31. A node whose number is greater than 63 cannot have a clrcnf operation performed on it. This is as designed. A clrallcnf can be done, or the node must be renumbered to less than 63 before running clrcnf (CSCdj14920).
32. The interface between a BXM feeder trunk and an MGX 8220 feeder is always considered to be an NNI interface. (CSCdj16808)
33. When adding more than 4000 connections on a BPX node, the VC polling rate must be changed to a higher interval, to accommodate the additional time needed to poll for the statistics for each VC. The cnfsysparm command, parameter 24, must be changed according to the following:
| Polling Rate: 5 Minutes (or higher) | |
| Polling Rate: 10 Minutes (or higher) | |
| Polling Rate: 15 Minutes | |
34. Given a connection that terminates on an IGX 8400 FRM at one end and an ASI on the other end, tstdelay initiated at the FRM end may not work if the ASI firmware is below the appropriate revision and does not support OAM cells as opposed to supervisory cells. This is because the updated BTM on the IGX will always generate OAM cells. Please check the Compatibility Matrix.
35. Because the detailed card error event log is not retained within BRAM, this information will be lost should a processor rebuild occur. Therefore, when issuing a dspcderrs command on a particular slot, the display will not show the detailed card error information should a rebuild event occur. This functionality has not been modified from previous releases.
36. When a physical-layer failure (for example, LOS) is detected on the BXM, a Major Alarm is generated, and any connection routed over that port is downed (fail state). The software sends a command to the remote end of the connection to generate AIS in the egress direction (CSCdj30543).
37. There are problems in the downgrade mechanism that can cause database corruption. If a downgrade is performed immediately after upgrading, the Stby_Info revision fields are not yet filled in on the new active CC. They don't get filled in until there is an upcard response from the new locked CC. This causes a restart instead of a switchcc. If the locked CC is reset, then downgrade immediately, a restart will occur instead of a switchcc. (CSCdj30811).
38. In order to test/simulate the Y-redundant switchover of ASI T3 or E3 pairs the resetcd command must be used, or by pulling out the active card. It will not be correctly simulated by doing a dncd (down card) on the active card. Using dncd will cause cell discards (CSCdj08923).
39. UBR traffic gains an advantage over ABR traffic when UBR and ABR PVCs are combined on the same network. This is because UBR and ABR PVCs share the same Qbin (Class of Service Queue) on the BXM card. ABR PVCs use a flow control mechanism, VSVD, which ensures that traffic sources slow down when the Qbin usage exceeds the EFCI threshold. However, UBR PVCs do not have this throttling mechanism. Therefore, ABR will throttle back whereas UBR will not. This unfair advantage is not considered a problem, since the decision to share a Qbin for ABR and UBR traffic was intentional. Any best-effort service that one would route over UBR can be routed over ABR(VSVD), with the additional benefit of protecting resources in the network. If UBR and ABR PVCs are required then:
Step 2 Enable VSVD.
Step 3 Disable FCES (Flow Control External Segment).
Step 4 Disable DEFAULT EXTENDED PARAMETERS.
Step 5 Choose policing option "4" to allow access as UBR.1 (PCR policing only). This connection has ABR VSVD in the network and allows UBR.1 access. The MCR for such ABRSTD connection may be set at the minimum acceptable value of 6 cells per second (explained later to do so).
40. Combining Frame Based Traffic Control (FBTC) and non-FBTC connections within a Class of Service can cause FBTC connections to not receive a fair share of bandwidth. For example, if VBR connections are added at a terminating port, and some of these VBR connections have FBTC enabled while other VBR connections have FBTC disabled, the VBR connections with FBTC disabled may obtain all of the excess bandwidth before the connections with FBTC enabled receive any of the excess bandwidth. The same holds true for ABR or UBR connections. This is relevant only where FBTC and non-FBTC connections share a Qbin, either at a port or at a trunk.
41. The maximum number of VC PARMs supported: 749 for BCC-32 MB, 2,999 for BCC-64 MB. (CSCdj48589).
42. Care must be taken when changing the Deroute Delay parameter, which is controlled by the cnftrk command. This defaults to zero, but if set to anything but zero, connection rerouting, due to a trunk failure, will be delayed as provided by the parameter.
1. When adding a node into an existing network, ensure that its node number is unique prior to a actually adding it into the network. Use the rnmnd command, and renumber the individual node while it is still stand-alone. This will make the joining of this node much simpler, and will avoid the problem of a node renumbering an active network, as described below.
2. There is a problem with node renumbering. Node renumbering (the rnmnd command) should be executed only during a stable network environment and only if absolutely necessary. A stable network environment would be, for example, one in which no connection was added for the past 30 minutes and no topology change was made in the last hour and there are no alarms or node unreachabilities. Node renumbering must be done only when the network is stable to reduce the possibility of certain temporarily blocked messages during the node renumbering process from being delivered to the wrong nodes. This would occur after the completion of the node renumbering process. It is recommended that a node be renumbered prior to being added to the network.
3. The settling time for network-wide updates can take a long time in certain situations. Specifically, the settling time for updates due to network-wide topology changes and connections in a large network when a processor switchover occurs can take a long time. The time is proportional to the number of nodes as well as the number of connections. A general estimate would be 30 seconds per node. During the period of transitions (when the updates are occurring) some network operations such as adding connections might in some cases take somewhat longer to complete.
4. When using Cisco Wan Manager, there could be a problem with communicating with a node that just had a processor switchover. The problem is within the SPARCstation itself and its caching of EtherNet addresses. It can be solved by execution the following command on the workstation as the superuser: # arp -d <node_name>
5. Users may not use the command addcon slot.1-24 v to add 24 voice connections to a CVM/UVM at once. Instead, they must separate this activity into two or more commands, so that no more than 16 connections are added at once. This is an issue only for voice connections. Data connections can be added using the "1-24" syntax. This also applies when the CVM/UVM circuit line is an E1, in which case "1-32" would apply (CSCdj14319).
6. Statistics must be disabled prior to the start of an upgrade, prior to the issuing of the first loadrev command. Statistics should be disabled from the Cisco Wan Manager, which is the Statistics collection manager.
7. Statistics sampling must be disabled prior to the start of an upgrade (using off1/off2), prior to the issuing of the first loadrev command. Statistics sampling state machines should be disabled from the Command Line Interface.
8. When a switchcc is executed on a BPX 8600 configured with two BCC-4 cards and contains a BXM-622 trunk card, there may be a bad clock path problem reported. It is indicated as a Minor Alarm - bad clock path. This is a transitory problem, although the alarm indication persists. To clear this, execute the clrclkalm command.
9. Currently, T3-3 and T3-2 back cards are not interchangeable between ASI and BNI front cards, as this has been the case since the introduction of these cards. The back cards must be configured using cnfbkcd (with setnovram) so as to avoid back card mismatch (CSCdj41999).
16-Bit Word | Byte # (hex) | Contents |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Front card supports card synchronization
For a complete list of firmware revisions supported, see the Compatibility Matrix document, which is included in this release package.
This release will run with Release 4.0.0x, 4.1.0x, or 5.0.0x of the MGX 8220.
PCB Description | dspcds Name | Card Name in FW Image | Model | Latest F/W | Min F/W |
|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PCB Description | dspcds Name | Card Name in Firmware Image | Model | Latest F/W | Min F/W |
|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
![]() |
Note IGX-UVM model E is a superset of models A, B, and C firmware. A, B, and C are obsoleted and should not be used. |
PCB Description | CW2000 Name | Latest F/W | Min F/W |
|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PCB Description | CW2000 Name | Latest F/W | Min F/W |
|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Card Type | Part Numbers | Latest H/W | Min. H/W |
|---|---|---|---|
Controller Cards | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Alarm Group | |||
|
|
|
|
|
|
|
|
|
|
|
|
BroadBand Switch Group | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Card Type | Part Numbers | Latest H/W | Min. H/W | * Note Below |
|---|---|---|---|---|
Controller Cards | ||||
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
|
Alarm Group | ||||
|
|
|
| |
|
|
|
| |
Trunk Group | ||||
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
Port Group | ||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
The following is the list of known anomalies in this Switch Software delivery. Included with each is a brief discussion of the problem. A more in-depth discussion is available in the release note enclosure of the problem record in Bug Navigator.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The following is the list of known anomalies in previous Switch Software deliveries. Included with each is a brief description of the problem. A more in depth description is available in the release note enclosure of the problem record in Bug Navigator.
Bug ID | Disposition of Anomaly |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
![]() |
Note These anomalies were closed because they were internally found (and not customer-found). Also, in most cases, they either require significant effort to resolve, are unreproducible, or have a benign effect on the system. |
Following is the list of fixed problems in the 9.2.34 Switch Software release. Included with each is a brief discussion of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.33 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.32 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.31 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.30 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.23 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
Following is the list of fixed problems in the 9.2.22 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.21 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.20 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.10 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Following is the list of fixed problems in the 9.2.01 Switch Software release. Included with each is a brief description of the problem.
Bug ID | Description |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The SNMP IGX/BPX switch SNMP MIB is being provided with the delivery of Release 9.2.33 Switch Software. The MIB is in standard ASN.1 format and is located in the ASCII text files agent.m, ilmi.m, ilmi_ctl.m, ilmiaddr.m, switch.m, swtraps.m, and errors.m which are included in the same directory as the Switch Software images. These files may be compiled with most standards-based MIB compilers.
The following Switch MIB changes were introduced since Release 9.2.00. The changes include Obsolete objects, Modified objects, and New objects:
New objects:
switchIfCtrlVPI switchIfCtrlVCIStart
Modified objects:
switchIfEntry switchIfScTmpltId
New objects:
atmPortHcfShift
Modified objects:
atmPortEntry atmPortMetro
Modified objects:
atmPortQueueType atmPortQueueDepth
Modified objects:
connCurrRouteDesc connPrefRouteDesc
Modified objects:
atmEndptDesc atmOtherEndptDesc atmEndptSubType atmEndptMCR
Modified objects:
atmBwClassConType
The following objects are associated with the switchShelf configuration branch.
shelfCnfgFBTC shelfCnfgSerialLeadTypeIndex shelfCnfgSerialLeadMonitorTimer shelfCnfgSystemTime
Modified objects:
slotBackType slotFrontNumPort slotBackSonetMode slotCardMinBusUBU
Modified objects:
sonetIfType
New objects:
sonetStatsYelTcs sonetStatsAisTcs sonetStatsLocs sonetStatsLops sonetStatsPthAis sonetStatsPthYels sonetStatsSecBip8s sonetStatsLnBip24s sonetStatsLnFebes sonetStatsPthBip8s sonetStatsPthFebes sonetStatsSecBip8Es sonetStatsLnBip24Es sonetStatsLnFebeEs sonetStatsPthBip8Es sonetStatsPthFebeEs sonetStatsSecBip8Ses sonetStatsSecSefs sonetStatsLnBip24Ses sonetStatsLnFebeSes sonetStatsPthBip8Ses sonetStatsPthFebeSes sonetStatsLnUas sonetStatsLnFarendUas sonetStatsPthUas sonetStatsPthFarendUas sonetStatsHcsCrtblErrEs
Modified objects:
sonetStatsEntry
Modified objects:
atmTrkType atmTrkTrafCls
New objects:
rsrcPartiVsiIlmiEnable
Modified objects:
rsrcPartiEntry rsrcPartiVsiVpiEnd
New objects:
serialPortLeadState
Modified objects:
SerialPortEntry serialPortLeadState
The default values for BXM and Enhanced-BXM cards are the same.
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
System-Wide Parameters
1 Max Time Stamped Packet Age (msec) ................................ 32
2 Allow CPU Starvation of Fail Handler .............................. No
3 Max Network Delay for 'v' connections (msec)....................... 14
4 Max Network Delay for 'c' connections (msec)....................... 27
5 Max Network Delay for 't' & 'p' connections (msec)................. 14
6 Max Network Delay for 'a' connections (msec)....................... 27
7 Max Network Delay for High Speed Data connections (msec)........... 32
8 Max Network Delay for CDP-CDP 'v' connections (msec)............... 64
9 Max Network Delay for CDP-CDP 'c' connections (msec)............... 64
10 Max Network Delay for CDP-CDP 't' & 'p' connections (msec)......... 64
11 Max Network Delay for CDP-CDP 'a' connections (msec)............... 64
12 Max Network Delay for CDP-CDP High Speed Data connections (msec)... 64
13 Enable Discard Eligibility......................................... No
14 Use Frame Relay Standard Parameters Bc and Be...................... No
15 Max Local Delay for Interdom CDP-CDP 'v' conns (msec).............. 27
16 Max Local Delay for Interdom CDP-CDP 'c' conns (msec).............. 27
17 Max Local Delay for Interdom CDP-CDP 't' & 'p' conns (msec)........ 27
18 Max Local Delay for Interdom CDP-CDP 'a' conns (msec).............. 27
19 Max Local Delay for Interdom CDP-CDP High Speed Data conns (msec).. 27
20 Max Local Delay for Interdom High Speed Data conns (msec).......... 28
21 FastPAD Jitter Buffer Size (msec)................................. 15
22 Number of Consecutive Invalid Login Attempts to Cause Major Alarm . 0
23 Enable Connection Deroute Delay feature............................ No
24 Interval Statistics polling rate for ATM VCs....................... 5
25 Interval Statistics polling rate for ports on IPX/IGX 8400 nodes... 5
This Command: cnfsysparm
1 Update Initial Delay [ 5000] (D) 16 Stats Memory (x 100KB) [ 132] (D)
2 Update Per-Node Delay [30000] (D) 17 Standby Update Timer [ 10] (D)
3 Comm-Break Test Delay [30000] (D) 18 Stby Updts Per Pass [ 50] (D)
4 Comm-Break Test Offset [ 10] (D) 19 Gateway ID Timer [ 30] (D)
5 Network Timeout Period [ 1700] (D) 20 GLCON Alloc Timer [ 30] (D)
6 Network Inter-p Period [ 4000] (D) 21 Comm Fail Delay [ 60] (D)
7 NW Sliding Window Size [ 1] (D) 22 Nw Hdlr Timer (msec) [ 50] (D)
8 Num Normal Timeouts [ 7] (D) 23 SAR CC Transmit Rate [ 560] (D)
9 Num Inter-p Timeouts [ 3] (D) 24 SAR High Transmit Rate [ 280] (D)
10 Num Satellite Timeouts [ 6] (D) 25 SAR Low Transmit Rate [ 56] (D)
11 Num Blind Timeouts [ 4] (D) 26 SAR VRAM Cngestn Limit [ 7680] (D)
12 Num CB Msg Timeouts [ 5] (D) 27 SAR VRAM Cell Discard [ 256] (D)
13 Comm Fail Interval [10000] (D) 28 ASM Card Cnfged [ Y] (Y/N)
14 Comm Fail Multiplier [ 3] (D) 29 TFTP Grant Delay (sec) [ 1] (D)
15 CC Redundancy Cnfged [ Y] (Y/N) 30 TFTP ACK Timeout (sec) [ 10] (D)
31 TFTP Write Retries [ 3] (D) 46 Max Htls Rebuild Count [ 100] (D)
32 SNMP Event logging [ Y] (Y/N) 47 Htls Counter Reset Time[ 1000] (D)
33 Job Lock Timeout [ 60] (D) 48 Send Abit early [ N] (Y/N)
34 Max Via LCONs [50000] (D) 49 Abit Tmr Multiplier M [ 0] (D)
35 Max Blind Segment Size [ 3570] (D) 50 Abit Tmr Granularity N [ 3] (D)
36 Max XmtMemBlks per NIB [ 3000] (D) 51 FBTC with PPDPolicing [ N] (Y/N)
37 Max Mem on Stby Q (%) [ 33] (D)
38 Stat Config Proc Cnt [ 1000] (D)
39 Stat Config Proc Delay [ 2000] (D)
40 Enable Degraded Mode [ Y] (Y/N)
41 Trk Cell Rtng Restrict [ Y] (Y/N)
42 Enable Feeder Alert [ N] (Y/N)
43 Reroute on Comm Fail [ N] (Y/N)
44 Auto Switch on Degrade [ Y] (Y/N)
45 Max Degraded Aborts [ 100] (D)
This Command: cnfnodeparm
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
Index Status Function
1 Enabled Automatic TRK Loopback Test on Local/Remote Alarms
2 Enabled User Command Logging
3 Enabled Automatic Card Reset on Hardware Error
4 Enabled Card Error Record Wraparound
5 Disabled Card Test After Failure
6 Disabled Download From Remote Cisco StrataView Plus
7 Disabled Logging of conn events in local event log
8 Disabled Logging of conn events in Cisco StrataView Plus event log
9 Disabled Force Download From a Specific IP address
This Command: cnffunc
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
Index Status Function
1 Disabled Configuration Save/Restore
2 Enabled ForeSight
3 Disabled Multiple VTs (1 session enabled)
4 Disabled Virtual Trunks
5 Enabled ABR standard with VSVD
This Command: cnfswfunc
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
Card Test - - - - - - Self Test - - - - - - - - - Background Test - - -
Type Freq Enable Inc Thresh Timeout Enable Inc Thresh
---- ----- -------- ------- ------- ------- -------- ------- -------
BCC 1600 Enabled 100 300 800 N/A 100 300
ASM 300 Disabled 100 300 60 N/A 100 300
BNI-T3 300 Enabled 100 300 150 N/A 100 300
BNI-E3 300 Enabled 100 300 150 N/A 100 300
ASI-E3 900 Enabled 100 300 800 Enabled 100 300
ASI-T3 900 Enabled 100 300 800 Enabled 100 300
ASI-155 900 Enabled 100 300 800 Enabled 100 300
BNI-155 300 Enabled 100 300 150 N/A 100 300
BXM 4000 Enabled 100 300 3000 Enabled 100 300
This Command: cnftstparm
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
1 Normalization Interval [ 2] (D)
2 Max Number To Normalize [ 5] (D)
3 Normalization Logging [ No]
4 Settling Interval [ 4] (D)
5 Minimum Open Space [ 1000] (D)
6 Normalization Priority [ Load]
7 Load Sample Period [ 4] (D)
8 Maximum Routing Bundle [ 90] (D)
9 Reroute Timer [ 0] (secs)
10 Reset Timer on Line Fail [ Yes]
11 Max Down/Up Per Pass [ 50] (D)
12 Down/Up Timer [30000] (msecs)
13 Max Route Errs per cycle [ 50] (D)
14 Time between Rrt cycles [ 5] (mins)
15 Max. Rrt Err cycles [ 10] (D)
16 Routing pause timer [ 0] (msecs)
17 Max msgs sent per update [ 10] (D)
18 Send SVC urgent msg [ No]
19 Max SVC Retry [ 0] (D)
20 Wait for TBL Updates [ 70] (100 msecs)
21 Max Derouting Bndl (0=all)[ 500] (D)
22 Enable Cost-Based Routing [ No]
23 Enable Route Cache Usage [ No]
24 Use Delay for Routing [ No]
25 # of reroute groups used [ 50] (D)
26 Starting size of RR grps [ 0] (CLU)
27 Increment between RR grps [ 100] (CLU)
This Command: cnfcmparm
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
1 Rmt Blk Freq (msec) [ 100] 16 FW Dnld Msgs/Block(dec) [ 4]
2 Rmt Blk Size (hex) [ 400] 17 Flash Write TO(msec) [ 16000]
3 Lcl Blk Freq (msec) [ 100] 18 Flash Erase TO(msec) [ 100]
4 Lcl Blk Size (hex) [ 400] 19 Erase Verify TO(msec) [ 16000]
5 Image Req Freq (msec) [ 10000] 20 Standby Flash TO(sec) [ 300]
6 Dnld Req Freq (msec) [ 10000] 21 Lcl Flash Init TO(msec) [ 1000]
7 Session Timeout (msec) [ 30000] 22 Flsh Write Blk Sz (hex) [ 10000]
8 Request Hop Limit (dec) [ 1] 23 Flsh Verfy Blk Sz (hex) [ 400]
9 Crc Throttle Freq (dec) [ 5000] 24 Chips Per Write/Erase [ 1]
10 Crc Block Size (hex) [ 400]
11 Rev Change Wait(dec) [ 0]
12 CCs Switch Wait(dec) [ 1000]
13 Lcl Response TO(msec) [ 5000]
14 Rmt Response TO(msec) [ 20000]
15 FW Dnld Block TO(msec) [ 50]
This Command: cnfdlparm
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
1. Logout Time ........... 20 minutes
2. VT Logout Time ........ 4 minutes
3. Prompt Time ........... 60 seconds
4. Command Time .......... 3 minutes
5. UID Privilege Level ... 6
6. Input Character Echo .. Enabled
7. Screen Update Time .... 10 seconds
This Command: cnfuiparm
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
Function Number Status Function Number Status
Background Upcard 1 Enabled Conn Stat Sampling 15 Enabled
Background Updates 2 Disabled Neighbor Update Errs 16 Disabled
Standby Terminal 3 Enabled
Memory Protection 4 Enabled
Comm Break 5 Enabled
Comm Fail Test 6 Enabled
CRC Test 7 Enabled
Bus Fail Detection 8 Enabled
Line Diag 9 Enabled
Clock Restoral 10 Enabled
Cm_Rerouting 11 Enabled
Clock Routing 12 Enabled
Dynamic BW Allocation 13 Enabled
Modem Polling 14 Enabled
This Command: on1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
Function Number Status Function Number Status
Line Stat Sampling 1 Enabled Robust Alarm Updates 15 Enabled
Statistical Alarm 2 Enabled Realtime Counters 16 Enabled
Job Ready Checker 3 Enabled LAN Interface 17 Enabled
Configuration Backup 4 Enabled Update Standby Stats 18 Enabled
Standby Update 5 Enabled Telnet Access 19 Enabled
Downloader 6 Enabled Junction ID 20 Enabled
Cm Updates 7 Enabled Mult SV+/Routing Node 21 Disabled
Topo/Stat Updates 8 Enabled Simulated Fdr Trks 22 Disabled
Card Statistical Alms 9 Enabled Deroute Delay 23 Enabled
Card Stat Sampling 10 Enabled Auto Renum Fail Recov 24 Enabled
Address Validation 11 Enabled Card Simulation Tool 25 Disabled
ASM Stats Polling 12 Enabled
Port Stat Sampling 13 Enabled
Robust Updates 14 Enabled
This Command: on2
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
Function Number Status
Region memory init 1 Disabled
Trace Msg Sent 2 Disabled
Multi-DB Stby Updates 3 Enabled
Trace Conv Msg 4 Disabled
This Command: on3
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 2.1 Config T3 [96000 cps] BNI-T3 slot: 2
Transmit Rate: 96000 VPC Conns disabled: --
Protocol By The Card: -- Line framing: PLCP
VC Shaping: -- coding: --
Hdr Type NNI: -- recv impedance: --
Statistical Reserve: 1000 cps cable type:
Idle code: 7F hex length: 0-225 ft.
Connection Channels: 1771 Pass sync: No
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR Loop clock: No
SVC Vpi Min: -- HCS Masking: Yes
SVC Channels: 0 Payload Scramble: No
SVC Bandwidth: 0 cps Frame Scramble: --
Restrict CC traffic: No Virtual Trunk Type: --
Link type: Terrestrial Virtual Trunk VPI: --
Routing Cost: 10 Deroute delay time: 0 seconds
Last Command: dsptrkcnf 2.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 2.1 Parameters
1 Q Depth - rt-VBR [ 242] (Dec) 15 Q Depth - CBR [ 600] (Dec)
2 Q Depth - Non-TS [ 360] (Dec) 16 Q Depth - nrt-VBR [ 1000] (Dec)
3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [ 8878] (Dec)
4 Q Depth - BData A [ 1000] (Dec) 18 Low CLP - CBR [ 100] (%)
5 Q Depth - BData B [ 8000] (Dec) 19 High CLP - CBR [ 100] (%)
6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - nrt-VBR [ 100] (%)
7 Max Age - rt-VBR [ 20] (Dec) 21 High CLP - nrt-VBR [ 100] (%)
8 Red Alm - I/O (Dec) [ 2500 / 15000]22 Low CLP/EPD-ABR [ 60] (%)
9 Yel Alm - I/O (Dec) [ 2500 / 15000]23 High CLP - ABR [ 80] (%)
10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 30] (%)
11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 0] (Dec)
12 Low CLP - BData B [ 25] (%)
13 High CLP - BData B [ 75] (%)
14 EFCN - BData B [ 30] (Dec)
This Command: cnftrkparm 2.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 3.1 Config E3 [80000 cps] BNI-E3 slot: 3
Transmit Rate: 80000 VPC Conns disabled: --
Protocol By The Card: -- Line framing: --
VC Shaping: -- coding: --
Hdr Type NNI: -- recv impedance: --
Statistical Reserve: 1000 cps cable type:
Idle code: 7F hex length: 0-225 ft.
Connection Channels: 1771 Pass sync: No
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR Loop clock: No
SVC Vpi Min: -- HCS Masking: Yes
SVC Channels: 0 Payload Scramble: Yes
SVC Bandwidth: 0 cps Frame Scramble: --
Restrict CC traffic: No Virtual Trunk Type: --
Link type: Terrestrial Virtual Trunk VPI: --
Routing Cost: 10 Deroute delay time: 0 seconds
Last Command: dsptrkcnf 3.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 3.1 Parameters
1 Q Depth - rt-VBR [ 202] (Dec) 15 Q Depth - CBR [ 600] (Dec)
2 Q Depth - Non-TS [ 300] (Dec) 16 Q Depth - nrt-VBR [ 1000] (Dec)
3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [ 8978] (Dec)
4 Q Depth - BData A [ 1000] (Dec) 18 Low CLP - CBR [ 100] (%)
5 Q Depth - BData B [ 8000] (Dec) 19 High CLP - CBR [ 100] (%)
6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - nrt-VBR [ 100] (%)
7 Max Age - rt-VBR [ 20] (Dec) 21 High CLP - nrt-VBR [ 100] (%)
8 Red Alm - I/O (Dec) [ 2500 / 15000]22 Low CLP/EPD-ABR [ 60] (%)
9 Yel Alm - I/O (Dec) [ 2500 / 15000]23 High CLP - ABR [ 80] (%)
10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 30] (%)
11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 0] (Dec)
12 Low CLP - BData B [ 25] (%)
13 High CLP - BData B [ 75] (%)
14 EFCN - BData B [ 30] (Dec)
This Command: cnftrkparm 3.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 4.1 Config OC3 [353207cps] BNI-155 slot: 4
Transmit Rate: 353208 VPC Conns disabled: --
Protocol By The Card: -- Line framing: STS-3C
VC Shaping: -- coding: --
Hdr Type NNI: -- recv impedance: --
Statistical Reserve: 1000 cps cable type: --
Idle code: 7F hex length: --
Connection Channels: 16050 Pass sync: No
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR Loop clock: No
SVC Vpi Min: -- HCS Masking: Yes
SVC Channels: 0 Payload Scramble: Yes
SVC Bandwidth: 0 cps Frame Scramble: Yes
Restrict CC traffic: No Virtual Trunk Type: --
Link type: Terrestrial Virtual Trunk VPI: --
Routing Cost: 10 Deroute delay time: 0 seconds
Last Command: dsptrkcnf 4.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 4.1 Parameters
1 Q Depth - rt-VBR [ 885] (Dec) 15 Q Depth - CBR [ 600] (Dec)
2 Q Depth - Non-TS [ 1324] (Dec) 16 Q Depth - nrt-VBR [ 1000] (Dec)
3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [15463] (Dec)
4 Q Depth - BData A [ 1000] (Dec) 18 Low CLP - CBR [ 100] (%)
5 Q Depth - BData B [ 8000] (Dec) 19 High CLP - CBR [ 100] (%)
6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - nrt-VBR [ 100] (%)
7 Max Age - rt-VBR [ 20] (Dec) 21 High CLP - nrt-VBR [ 100] (%)
8 Red Alm - I/O (Dec) [ 2500 / 10000]22 Low CLP/EPD-ABR [ 60] (%)
9 Yel Alm - I/O (Dec) [ 2500 / 10000]23 High CLP - ABR [ 80] (%)
10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 30] (%)
11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 0] (Dec)
12 Low CLP - BData B [ 25] (%)
13 High CLP - BData B [ 75] (%)
14 EFCN - BData B [ 30] (Dec)
This Command: cnftrkparm 4.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 5.1 Config T3 [96000 cps] BXM slot: 5
Transmit Rate: 96000 VPC Conns disabled: No
Protocol By The Card: No Line framing: PLCP
VC Shaping: No coding: --
Hdr Type NNI: Yes recv impedance: --
Statistical Reserve: 1000 cps cable type: --
Idle code: 7F hex length: 0-225 ft.
Connection Channels: 256 Pass sync: No
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR Loop clock: No
SVC Vpi Min: 0 HCS Masking: Yes
SVC Channels: 0 Payload Scramble: No
SVC Bandwidth: 0 cps Frame Scramble: --
Restrict CC traffic: No Virtual Trunk Type: --
Link type: Terrestrial Virtual Trunk VPI: --
Routing Cost: 10 Deroute delay time: 0 seconds
Last Command: dsptrkcnf 5.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 5.1 Parameters
1 Q Depth - rt-VBR [ 242] (Dec) 15 Q Depth - CBR [ 400] (Dec)
2 Q Depth - Non-TS [ 360] (Dec) 16 Q Depth - nrt-VBR [ 5000] (Dec)
3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [10000] (Dec)
4 Q Depth - BData A [ 8000] (Dec) 18 Low CLP - CBR [ 60] (%)
5 Q Depth - BData B [ 8000] (Dec) 19 High CLP - CBR [ 80] (%)
6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - nrt-VBR [ 60] (%)
7 Max Age - rt-VBR [ 20] (Dec) 21 High CLP - nrt-VBR [ 80] (%)
8 Red Alm - I/O (Dec) [ 2500 / 15000]22 Low CLP/EPD-ABR [ 60] (%)
9 Yel Alm - I/O (Dec) [ 2500 / 15000]23 High CLP - ABR [ 80] (%)
10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 20] (%)
11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 0] (Dec)
12 Low CLP - BData B [ 25] (%)
13 High CLP - BData B [ 75] (%)
14 EFCN - BData B [ 30] (Dec)
This Command: cnftrkparm 5.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set TRK 13.1 Config E3 [80000 cps] BXM slot: 13 Transmit Rate: 80000 VPC Conns disabled: No Protocol By The Card: No Line framing: -- VC Shaping: No coding: -- Hdr Type NNI: Yes recv impedance: -- Statistical Reserve: 1000 cps cable type: -- Idle code: 7F hex length: 0-225 ft. Connection Channels: 256 Pass sync: No Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR Loop clock: No SVC Vpi Min: 0 HCS Masking: Yes SVC Channels: 0 Payload Scramble: Yes SVC Bandwidth: 0 cps Frame Scramble: -- Restrict CC traffic: No Virtual Trunk Type: -- Link type: Terrestrial Virtual Trunk VPI: -- Routing Cost: 10 Deroute delay time: 0 seconds Last Command: dsptrkcnf 13.1 hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set TRK 13.1 Parameters 1 Q Depth - rt-VBR [ 202] (Dec) 15 Q Depth - CBR [ 400] (Dec) 2 Q Depth - Non-TS [ 300] (Dec) 16 Q Depth - nrt-VBR [ 5000] (Dec) 3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [10000] (Dec) 4 Q Depth - BData A [ 8000] (Dec) 18 Low CLP - CBR [ 60] (%) 5 Q Depth - BData B [ 8000] (Dec) 19 High CLP - CBR [ 80] (%) 6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - nrt-VBR [ 60] (%) 7 Max Age - rt-VBR [ 20] (Dec) 21 High CLP - nrt-VBR [ 80] (%) 8 Red Alm - I/O (Dec) [ 2500 / 15000]22 Low CLP/EPD-ABR [ 60] (%) 9 Yel Alm - I/O (Dec) [ 2500 / 15000]23 High CLP - ABR [ 80] (%) 10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 20] (%) 11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 0] (Dec) 12 Low CLP - BData B [ 25] (%) 13 High CLP - BData B [ 75] (%) 14 EFCN - BData B [ 30] (Dec) This Command: cnftrkparm 13.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 6.1 Config OC3 [353207cps] BXM slot: 6
Transmit Rate: 353208 VPC Conns disabled: No
Protocol By The Card: No Line framing: STS-3C
VC Shaping: No coding: --
Hdr Type NNI: Yes recv impedance: --
Statistical Reserve: 1000 cps cable type: --
Idle code: 7F hex length: --
Connection Channels: 256 Pass sync: No
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR Loop clock: No
SVC Vpi Min: 0 HCS Masking: Yes
SVC Channels: 0 Payload Scramble: Yes
SVC Bandwidth: 0 cps Frame Scramble: Yes
Restrict CC traffic: No Virtual Trunk Type: --
Link type: Terrestrial Virtual Trunk VPI: --
Routing Cost: 10 Deroute delay time: 0 seconds
Last Command: dsptrkcnf 6.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 6.1 Parameters
1 Q Depth - rt-VBR [ 885] (Dec) 15 Q Depth - CBR [ 600] (Dec)
2 Q Depth - Non-TS [ 1324] (Dec) 16 Q Depth - nrt-VBR [ 5000] (Dec)
3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [20000] (Dec)
4 Q Depth - BData A [10000] (Dec) 18 Low CLP - CBR [ 60] (%)
5 Q Depth - BData B [10000] (Dec) 19 High CLP - CBR [ 80] (%)
6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - nrt-VBR [ 60] (%)
7 Max Age - rt-VBR [ 20] (Dec) 21 High CLP - nrt-VBR [ 80] (%)
8 Red Alm - I/O (Dec) [ 2500 / 10000]22 Low CLP/EPD-ABR [ 60] (%)
9 Yel Alm - I/O (Dec) [ 2500 / 10000]23 High CLP - ABR [ 80] (%)
10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 20] (%)
11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 0] (Dec)
12 Low CLP - BData B [ 25] (%)
13 High CLP - BData B [ 75] (%)
14 EFCN - BData B [ 30] (Dec)
This Command: cnftrkparm 6.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 9.1 Config OC12 [1412679cps] BXM slot: 9
Transmit Rate: 1412830 VPC Conns disabled: No
Protocol By The Card: No Line framing: STS-12C
VC Shaping: No coding: --
Hdr Type NNI: Yes recv impedance: --
Statistical Reserve: 1000 cps cable type: --
Idle code: 7F hex length: --
Connection Channels: 256 Pass sync: No
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR Loop clock: No
SVC Vpi Min: 0 HCS Masking: Yes
SVC Channels: 0 Payload Scramble: Yes
SVC Bandwidth: 0 cps Frame Scramble: Yes
Restrict CC traffic: No Virtual Trunk Type: --
Link type: Terrestrial Virtual Trunk VPI: --
Routing Cost: 10 Deroute delay time: 0 seconds
Last Command: dsptrkcnf 9.1
hugo TN StrataCom BPX 8620 9.2.34 Date/Time Not Set
TRK 9.1 Parameters
1 Q Depth - rt-VBR [ 3533] (Dec) 15 Q Depth - CBR [ 1200] (Dec)
2 Q Depth - Non-TS [ 5297] (Dec) 16 Q Depth - nrt-VBR [10000] (Dec)
3 Q Depth - TS [ 1000] (Dec) 17 Q Depth - ABR [40000] (Dec)
4 Q Depth - BData A [40000] (Dec) 18 Low CLP - CBR [ 60] (%)
5 Q Depth - BData B [40000] (Dec) 19 High CLP - CBR [ 80] (%)
6 Q Depth - High Pri [ 1000] (Dec) 20 Low CLP - nrt-VBR [ 60] (%)
7 Max Age - rt-VBR [ 20] (Dec) 21 High CLP - nrt-VBR [ 80] (%)
8 Red Alm - I/O (Dec) [ 2500 / 10000]22 Low CLP/EPD-ABR [ 60] (%)
9 Yel Alm - I/O (Dec) [ 2500 / 10000]23 High CLP - ABR [ 80] (%)
10 Low CLP - BData A [ 100] (%) 24 EFCN - ABR [ 20] (%)
11 High CLP - BData A [ 100] (%) 25 SVC Queue Pool Size [ 0] (Dec)
12 Low CLP - BData B [ 25] (%)
13 High CLP - BData B [ 75] (%)
14 EFCN - BData B [ 30] (Dec)
This Command: cnftrkparm 9.1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
System-Wide Parameters
1 Max Time Stamped Packet Age (msec) ................................ 32
2 Allow CPU Starvation of Fail Handler .............................. No
3 Max Network Delay for 'v' connections (msec)....................... 14
4 Max Network Delay for 'c' connections (msec)....................... 27
5 Max Network Delay for 't' & 'p' connections (msec)................. 14
6 Max Network Delay for 'a' connections (msec)....................... 27
7 Max Network Delay for High Speed Data connections (msec)........... 32
8 Max Network Delay for CDP-CDP 'v' connections (msec)............... 64
9 Max Network Delay for CDP-CDP 'c' connections (msec)............... 64
10 Max Network Delay for CDP-CDP 't' & 'p' connections (msec)......... 64
11 Max Network Delay for CDP-CDP 'a' connections (msec).............. 64
12 Max Network Delay for CDP-CDP High Speed Data connections (msec)... 64
13 Enable Discard Eligibility......................................... No
14 Use Frame Relay Standard Parameters Bc and Be...................... No
15 Max Local Delay for Interdom CDP-CDP 'v' conns (msec).............. 27
16 Max Local Delay for Interdom CDP-CDP 'c' conns (msec).............. 27
17 Max Local Delay for Interdom CDP-CDP 't' & 'p' conns (msec)........ 27
18 Max Local Delay for Interdom CDP-CDP 'a' conns (msec).............. 27
19 Max Local Delay for Interdom CDP-CDP High Speed Data conns (msec).. 27
20 Max Local Delay for Interdom High Speed Data conns (msec).......... 28
21 FastPAD Jitter Buffer Size (msec)................................. 15
22 Number of Consecutive Invalid Login Attempts to Cause Major Alarm . 0
23 Enable Connection Deroute Delay feature ........................... No
24 Interval Statstics polling rate for ATM/Frame Relay VCs............ 5
25 Interval Statistics polling rate for ports......................... 5
This Command: cnfsysparm
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
1 Update Initial Delay [ 5000] (D) 16 CC Redundancy Cnfged [ Y] (Y/N)
2 Update Per-Node Delay [30000] (D) 17 MT3 Pass Through Relay [ Y] (Y/N)
3 Comm-Break Test Delay [30000] (D) 18 Nw Pkt Tx Rate (pps) [ 500] (D)
4 Comm-Break Test Offset [ 10] (D) 19 Stats Memory (x 100KB) [ 130] (D)
5 Network Timeout Period [ 1700] (D) 20 Standby Update Timer [ 10] (D)
6 Network Inter-p Period [ 4000] (D) 21 Stby Updts Per Pass [ 50] (D)
7 NW Sliding Window Size [ 1] (D) 22 Gateway ID Timer [ 30] (D)
8 Num Normal Timeouts [ 7] (D) 23 GLCON Alloc Timer [ 30] (D)
9 Num Inter-p Timeouts [ 3] (D) 24 Comm Fail Delay [ 60] (D)
10 Num Satellite Timeouts [ 6] (D) 25 Nw Hdlr Timer (msec) [ 100] (D)
11 Num Blind Timeouts [ 4] (D) 26 CBUS Delay (msec) [ 20] (D)
12 Num CB Msg Timeouts [ 2] (D) 27 SNMP Event logging [ Y] (Y/N)
13 Comm Fail Interval [10000] (D) 28 TFTP Grant Delay (sec) [ 1] (D)
14 Comm Fail Multiplier [ 3] (D) 29 TFTP ACK Timeout (sec) [ 10] (D)
15 Temperature Threshold [ 50] (D) 30 TFTP Write Retries [ 3] (D)
31 FRP Link Status Alarm [ Y] (Y/N) 46 Modem polling timer [ 1] (D)
32 Job Lock Timeout [ 1000] (D) 47 Verify CBA for non-FRP [ N] (Y/N)
33 Max Via LCONs [20000] (D) 48 Send Abit early [ N] (Y/N)
34 Max Blind Segment Size [ 3570] (D) 49 Abit Tmr Multiplier M [ 0] (D)
35 Max XmtMemBlks per NIB [ 3000] (D) 50 Abit Tmr Granularity N [ 3] (D)
36 Max Mem on Stby Q (%) [ 33] (D)
37 Trk Cell Rtng Restrict [ Y] (Y/N)
38 Stat Config Proc Cnt [ 1000] (D)
39 Stat Config Proc Delay [ 2000] (D)
40 Enable Degraded Mode [ Y] (Y/N)
41 Enable Rrt on Comm Fail[ N] (Y/N)
42 Auto Switch on Degrade [ Y] (Y/N)
43 Max Degraded Aborts [ 100] (D)
44 Max Htls Rebuild Count [ 100] (D)
45 Htls Counter Reset Time[ 1000] (D)
This Command: cnfnodeparm
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
Index Status Function
1 Enabled Automatic CLN/PLN Loopback Test on Local/Remote Alarms
2 Enabled FDP Loopback button
3 Enabled User Command Logging
4 Enabled Automatic Card Reset on Hardware Error
5 Enabled TXR Model D Download
6 Enabled Card Error Record Wraparound
7 Disabled Card Test After Failure
8 Disabled Download From Remote Cisco StrataView Plus
9 Disabled Logging of conn events in local event log
10 Disabled Logging of conn events in Cisco StrataView Plus event log
11 Disabled Logging SVC Connection Events
12 Disabled Force Download From a Specific IP address
13 Disabled CDP WinkStart Signalling
14 Enabled Logging of Bus Diagnostic Events in local event log
15 Enabled Automatic Card Reset after Burnfw for CBI cards
This Command: cnffunc
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
Index Status Function
1 Disabled Data Frame Multiplexing
2 Disabled Adaptive Voice
3 Enabled Frame Relay
4 Disabled Configuration Save/Restore
5 Disabled ForeSight
6 Disabled Frame Relay Network-to-Network Interface
7 Disabled Multiple VTs (1 session enabled)
8 Disabled Interface Shelf
9 Enabled Virtual Trunks
10 Disabled ABR standard with VSVD
This Command: cnfswfunc
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
Card Test - - - - - - Self Test - - - - - - - - - Background Test - - -
Type Freq Enable Inc Thresh Timeout Enable Inc Thresh
---- ----- -------- ------- ------- ------- -------- ------- -------
PSM 300 Enabled 100 300 31 N/A 100 300
HDM 300 Enabled 100 300 80 Enabled 100 300
LDM 300 Enabled 100 300 80 Enabled 100 300
NTM 300 Enabled 100 300 31 N/A 100 300
FRM 300 Enabled 100 300 80 Enabled 100 300
MT3 300 Enabled 100 300 50 N/A 100 300
CVM 300 Enabled 100 300 300 N/A 100 300
NPM 180 Enabled 100 300 120 N/A 100 300
ARM 300 Enabled 100 300 60 N/A 100 300
BTM 300 Enabled 100 300 120 N/A 100 300
FTM 300 Enabled 100 300 80 Disabled 100 300
UFM 300 Enabled 100 300 80 Enabled 100 300
UFMU 300 Enabled 100 300 80 Enabled 100 300
ALM 300 Enabled 100 300 120 N/A 100 300
UVM 300 Disabled 100 300 60 N/A 100 300
UXM 300 Enabled 100 300 800 Enabled 100 300
This Command: cnftstparm
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
1 Normalization Interval [ 2] (D)
2 Max Number To Normalize [ 5] (D)
3 Normalization Logging [ No]
4 Settling Interval [ 4] (D)
5 Minimum Open Space [ 1000] (D)
6 Normalization Priority [ Load]
7 Load Sample Period [ 4] (D)
8 Maximum Routing Bundle [ 90] (D)
9 Reroute Timer [ 0] (secs)
10 Reset Timer on Line Fail [ Yes]
11 Max Down/Up Per Pass [ 50] (D)
12 Down/Up Timer [30000] (msecs)
13 Max Route Errs per cycle [ 200] (D)
14 Time between Rrt cycles [ 5] (mins)
15 Max. Rrt Err cycles [ 1] (D)
16 Routing pause timer [ 0] (msecs)
17 Max msgs sent per update [ 10] (D)
18 Send SVC urgent msg [ Yes]
19 Max SVC Retry [ 0] (D)
20 Wait for TBL Updates [ 70] (100 msecs)
21 Max Derouting Bndl (0=all)[ 500] (D)
22 Enable Cost-Based Routing [ No]
23 Enable Route Cache Usage [ No]
24 Use Delay for Routing [ No]
25 # of reroute groups used [ 50] (D)
26 Starting size of RR grps [ 0] (CLU)
27 Increment between RR grps [ 100] (CLU)
This Command: cnfcmparm
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
1 Rmt Blk Freq (msec) [ 100] 16 FW Dnld Msgs/Block(dec) [ 4]
2 Rmt Blk Size (hex) [ 400] 17 Flash Write TO(msec) [ 16000]
3 Lcl Blk Freq (msec) [ 100] 18 Flash Erase TO(msec) [ 100]
4 Lcl Blk Size (hex) [ 400] 19 Erase Verify TO(msec) [ 16000]
5 Image Req Freq (msec) [ 10000] 20 Standby Flash TO(sec) [ 300]
6 Dnld Req Freq (msec) [ 10000] 21 Lcl Flash Init TO(msec) [ 1000]
7 Session Timeout (msec) [ 30000] 22 Flsh Write Blk Sz (hex) [ 10000]
8 Request Hop Limit (dec) [ 1] 23 Flsh Verfy Blk Sz (hex) [ 400]
9 Crc Throttle Freq (dec) [ 5000] 24 Chips Per Write/Erase [ 1]
10 Crc Block Size (hex) [ 400]
11 Rev Change Wait(dec) [ 0]
12 CCs Switch Wait(dec) [ 1000]
13 Lcl Response TO(msec) [ 5000]
14 Rmt Response TO(msec) [ 30000]
15 FW Dnld Block TO(msec) [ 50]
This Command: cnfdlparm
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
1. Logout Time ........... 20 minutes
2. VT Logout Time ........ 4 minutes
3. Prompt Time ........... 60 seconds
4. Command Time .......... 3 minutes
5. UID Privilege Level ... 6
6. Input Character Echo .. Enabled
7. Screen Update Time .... 10 seconds
This Command: cnfuiparm
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
Function Number Status Function Number Status
Background Upcard 1 Enabled Dynamic BW Allocation 15 Enabled
Background Updates 2 Disabled Modem Polling 16 Enabled
Standby Terminal 3 Disabled Conn Stat Sampling 17 Enabled
Memory Protection 4 Enabled SVC Del Bgnd Updates 18 Disabled
Comm Break 5 Enabled FastPAD Test 19 Enabled
Comm Fail Test 6 Enabled Neighbor Update Errs 20 Disabled
BRAM Memory Protect 7 Enabled
CRC Test 8 Enabled
CDT Clock Test 9 Enabled
Bus Fail Detection 10 Enabled
Line Diag 11 Enabled
Clock Restoral 12 Enabled
Cm_Rerouting 13 Enabled
Clock Routing 14 Enabled
This Command: on1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
Function Number Status Function Number Status
Line Stat Sampling 1 Enabled LAN Interface 15 Enabled
Statistical Alarm 2 Enabled Update Standby Stats 16 Enabled
Job Ready Checker 3 Enabled EIA Monitoring 17 Enabled
Configuration Backup 4 Enabled Telnet Access 18 Enabled
Standby Update 5 Enabled Junction ID 19 Enabled
Downloader 6 Enabled Mult SV+/Routing Node 20 Enabled
Cm Updates 7 Enabled Feeder with NW Trunks 21 Disabled
Power Supply Monitor 8 Enabled Multiple Fdr Trunks 22 Disabled
Topo/Stat Updates 9 Enabled Simulated Fdr Trks 23 Disabled
CDP/CIP Sig. Polling 10 Enabled Auto Renum Fail Recov 24 Enabled
Port Stat Sampling 11 Enabled IGX - ACM Selftest 25 Enabled
Robust Updates 12 Enabled Card Simulation Tool 26 Enabled
Robust Alarm Updates 13 Enabled Major Alarm on NNI 27 Disabled
Realtime Counters 14 Enabled Deroute Delay 28 Enabled
This Command: on2
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
Function Number Status
Region memory init 1 Disabled
Trace Msg Sent 2 Disabled
Multi-DB Stby Updates 3 Enabled
AIT/BTM/ALM 32h Ext2 4 Enabled
Card Synchronization 5 Disabled
Loop Access Dev Init 6 Disabled
Auto allocate UXM UBU 7 Disabled
Trace Conv Msg 8 Disabled
Automatic Cbus Diags 9 Disabled
CBUS Flood Protection 10 Enabled
This Command: on3
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 5 Config SR/30 [10000 pps] NTM slot:5
Subrate interface: X.21
Subrate data rate: 1920 kbps
Pass sync: No
Loop clock: Yes
Statistical Reserve: 600
Routing Cost: 10
Restrict PCC traffic: No
Link type: Terrestrial
Traffic: V,TS,NTS,FR,FST
Deroute delay time: 0 seconds
Last Command: dsptrkcnf 5
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 5 Parameters:
1 Yel Alm-In/Out (D) [ 1000/ 2000] 18 Red Alm-In/Out (D) [ 1000/ 2000]
2 Rx Max Age - rt-VBR (D) [ N/A] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ N/A] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ N/A]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ N/A] 21 BDataA [ 128] 23 BDataA [ 128]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ 128] 24 BDataB [ 128]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ N/A] 10 BDataA [ N/A] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ N/A] 11 BdataB [ N/A] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ N/A] 15 BDataA [ N/A] 29 rt-VBR [ 27] 32 BDataA [ 600]
13 Non TS [ N/A] 16 BDataB [ N/A] 30 Non TS [ 37] 33 BDataB [ 600]
14 TS [ N/A] 17 HighPri[ N/A] 31 TS [ 2636] 34 HighPri[ 100]
This Command: cnftrkparm 5
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 4 Config E1/32 [10666 pps] NTM slot:4
Line DS-0 map: 0-31
Pass sync: Yes
Loop clock: No
Statistical Reserve: 600 pps
Routing Cost: 10
Idle code: 54 hex
Restrict PCC traffic: No
Link type: Terrestrial
Line coding: HDB3
Line CRC: No
Line recv impedance: 75 ohm + gnd
Traffic: V,TS,NTS,FR,FST
Deroute delay time: 0 seconds
Last Command: dsptrkcnf 4
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 4 Parameters:
1 Yel Alm-In/Out (D) [ 1000/ 2000] 18 Red Alm-In/Out (D) [ 1000/ 2000]
2 Rx Max Age - rt-VBR (D) [ N/A] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ N/A] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ N/A]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ N/A] 21 BDataA [ 128] 23 BDataA [ 128]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ 128] 24 BDataB [ 128]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ N/A] 10 BDataA [ N/A] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ N/A] 11 BdataB [ N/A] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ N/A] 15 BDataA [ N/A] 29 rt-VBR [ 28] 32 BDataA [ 600]
13 Non TS [ N/A] 16 BDataB [ N/A] 30 Non TS [ 40] 33 BDataB [ 600]
14 TS [ N/A] 17 HighPri[ N/A] 31 TS [ 2632] 34 HighPri[ 100]
This Command: cnftrkparm 4
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 4 Config E1/32 [10666 pps] NTM slot:4
Line DS-0 map: 0-31
Pass sync: Yes
Loop clock: No
Statistical Reserve: 600 pps
Routing Cost: 10
Idle code: 54 hex
Restrict PCC traffic: No
Link type: Terrestrial
Line coding: HDB3
Line CRC: No
Line recv impedance: 75 ohm + gnd
Traffic: V,TS,NTS,FR,FST
Deroute delay time: 0 seconds
Last Command: dsptrkcnf 4
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 4 Parameters:
1 Yel Alm-In/Out (D) [ 1000/ 2000] 18 Red Alm-In/Out (D) [ 1000/ 2000]
2 Rx Max Age - rt-VBR (D) [ N/A] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ N/A] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ N/A]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ N/A] 21 BDataA [ 128] 23 BDataA [ 128]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ 128] 24 BDataB [ 128]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ N/A] 10 BDataA [ N/A] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ N/A] 11 BdataB [ N/A] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ N/A] 15 BDataA [ N/A] 29 rt-VBR [ 28] 32 BDataA [ 600]
13 Non TS [ N/A] 16 BDataB [ N/A] 30 Non TS [ 40] 33 BDataB [ 600]
14 TS [ N/A] 17 HighPri[ N/A] 31 TS [ 2632] 34 HighPri[ 100]
This Command: cnftrkparm 4
mulder TRM StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 6 Config T3/3 [1000 pps] ALM slot:6
Transmit Trunk Rate: 96000 cps HCS Masking: Yes
Rcv Trunk Rate: 1000 pps Payload Scramble: No
Pass sync: Yes Traffic: V,TS,NTS,FR,FST
Loop clock: No Deroute delay time: 0 seconds
Statistical Reserve: 1000 pps
Header Type: STI
Gateway Type: BAM
VPI Address: 0
VCI Address: 0
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Line cable length: 0-225 ft.
Last Command: dsptrkcnf 6
mulder TRM StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 6 Parameters:
1 Yel Alm-In/Out (D) [ 2500/ 15000] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 30] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ N/A] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ 100] 10 BDataA [ 100] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ 75] 11 BdataB [ 25] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 4] 15 BDataA [ 1000] 29 rt-VBR [ 532] 32 BDataA [ 1000]
13 Non TS [ 3] 16 BDataB [ 8000] 30 Non TS [ 795] 33 BDataB [ 8000]
14 TS [ 5993] 17 HighPri[ 1000] 31 TS [ 4673] 34 HighPri[ 1000]
This Command: cnftrkparm 6
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 9 Config HSSI/3 [1000 pps] BTM slot:9
Clock Rate: 50840000 bps Line cable length: 0-225 ft.
Transmit Trunk Rate: 111491 cps HCS Masking: Yes
Rcv Trunk Rate: 1000 pps Payload Scramble: No
Pass sync: No Traffic: V,TS,NTS,FR,FST
Loop clock: No Deroute delay time: 0 seconds
Statistical Reserve: 1000 pps
Header Type: STI
Gateway Type: BAM
VPI Address: 0
VCI Address: 0
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Last Command: dsptrkcnf 9
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 9 Parameters:
1 Yel Alm-In/Out (D) [ 2500/ 15000] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 30] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ 30] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ 100] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ 100] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ 100] 10 BDataA [ 100] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ 75] 11 BdataB [ 25] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 4] 15 BDataA [ 2264] 29 rt-VBR [ 617] 32 BDataA [ 2264]
13 Non TS [ 3] 16 BDataB [ 2264] 30 Non TS [ 922] 33 BDataB [ 2264]
14 TS [11365] 17 HighPri[ 100] 31 TS [ 9833] 34 HighPri[ 100]
This Command: cnftrkparm 9
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 10 Config E1/32 [10666 pps] BTM slot:10
Line DS-0 map: 0-31 Line coding: HDB3
Transmit Trunk Rate: 4830 cps Line CRC: No
Rcv Trunk Rate: 10666 pps Line recv impedance: 75 ohm + gnd
Pass sync: Yes HCS Masking: Yes
Loop clock: No Payload Scramble: Yes
Statistical Reserve: 600 pps Traffic: V,TS,NTS,FR,FST
Header Type: STI Deroute delay time: 0 seconds
Gateway Type: BAM
VPI Address: 0
VCI Address: 0
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Last Command: dsptrkcnf 10
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 10 Parameters:
1 Yel Alm-In/Out (D) [ 1000/ 2000] 18 Red Alm-In/Out (D) [ 1000/ 2000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 30] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ N/A]
5 EFCN - Rx Space (D) [ 30] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ 100] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ 100] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ 100] 10 BDataA [ 100] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ 75] 11 BdataB [ 25] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 28] 15 BDataA [ 600] 29 rt-VBR [ 28] 32 BDataA [ 600]
13 Non TS [ 40] 16 BDataB [ 600] 30 Non TS [ 40] 33 BDataB [ 600]
14 TS [14632] 17 HighPri[ 100] 31 TS [14632] 34 HighPri[ 100]
This Command: cnftrkparm 10
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 11 Config E2/3 [1000 pps] BTM slot:11
Transmit Trunk Rate: 19900 cps HCS Masking: Yes
Rcv Trunk Rate: 1000 pps Payload Scramble: Yes
Pass sync: Yes Traffic: V,TS,NTS,FR,FST
Loop clock: No Deroute delay time: 0 seconds
Statistical Reserve: 1000 pps
Header Type: STI
Gateway Type: BAM
VPI Address: 0
VCI Address: 0
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Line cable length: 0-225 ft.
Last Command: dsptrkcnf 11
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 11 Parameters:
1 Yel Alm-In/Out (D) [ 2500/ 15000] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 30] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ 30] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ 100] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ 100] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ 100] 10 BDataA [ 100] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ 75] 11 BdataB [ 25] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 4] 15 BDataA [ 2264] 29 rt-VBR [ 111] 32 BDataA [ 2264]
13 Non TS [ 3] 16 BDataB [ 2264] 30 Non TS [ 163] 33 BDataB [ 2264]
14 TS [11365] 17 HighPri[ 100] 31 TS [11098] 34 HighPri[ 100]
This Command: cnftrkparm 11
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 7 Config E3/3 [1000 pps] BTM slot:7
Transmit Trunk Rate: 80000 cps HCS Masking: Yes
Rcv Trunk Rate: 1000 pps Payload Scramble: Yes
Pass sync: Yes Traffic: V,TS,NTS,FR,FST
Loop clock: No Deroute delay time: 0 seconds
Statistical Reserve: 1000 pps
Header Type: STI
Gateway Type: BAM
VPI Address: 0
VCI Address: 0
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Line cable length: 0-225 ft.
Last Command: dsptrkcnf 7
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 7 Parameters:
1 Yel Alm-In/Out (D) [ 2500/ 15000] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 30] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ 30] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ 100] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ 100] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ 100] 10 BDataA [ 100] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ 75] 11 BdataB [ 25] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 4] 15 BDataA [ 2264] 29 rt-VBR [ 443] 32 BDataA [ 2264]
13 Non TS [ 3] 16 BDataB [ 2264] 30 Non TS [ 662] 33 BDataB [ 2264]
14 TS [11365] 17 HighPri[ 100] 31 TS [10267] 34 HighPri[ 100]
This Command: cnftrkparm 7
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 8 Config T3/3 [1000 pps] BTM slot:8
Transmit Trunk Rate: 96000 HCS Masking: Yes
Rcv Trunk Rate: 1000 pps Payload Scramble: No
Pass sync: Yes Traffic: V,TS,NTS,FR,FST
Loop clock: No Deroute delay time: 0 seconds
Statistical Reserve: 1000 pps
Header Type: STI
Gateway Type: BAM
VPI Address: 0
VCI Address: 0
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Line cable length: 0-225 ft.
Last Command: dsptrkcnf 8
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 8 Parameters:
1 Yel Alm-In/Out (D) [ 2500/ 15000] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 30] 20 Tx EFCN - BdataB (D) [ 30]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ 30] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP - Rx_Space (%) [ 100] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ 100] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP (%) Tx High CLP (%) Tx Low CLP (%)
8 BDataA [ 100] 10 BDataA [ 100] 25 BDataA [ 100] 27 BDataA [ 100]
9 BDataB [ 75] 11 BdataB [ 25] 26 BDataB [ 75] 28 BDataB [ 25]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 4] 15 BDataA [ 2264] 29 rt-VBR [ 532] 32 BDataA [ 2264]
13 Non TS [ 3] 16 BDataB [ 2264] 30 Non TS [ 795] 33 BDataB [ 2264]
14 TS [11365] 17 HighPri[ 100] 31 TS [10045] 34 HighPri[ 100]
This Command: cnftrkparm 8
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 13.1 Config E1/30 [4528 cps] UXM slot:13
Line DS-0 map: 1-15,17-31 Line coding: HDB3
IMA Group Member(s): 1 Line recv impedance: 120 ohm
Retained links: 1 HCS Masking: Yes
Transmit Trunk Rate: 4528 cps Payload Scramble: Yes
Rcv Trunk Rate: 4528 cps Connection Channels: 256
Pass sync: Yes Gateway Channels: 200
Loop clock: No Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Statistical Reserve: 600 cps IMA Protocol Option: Disabled
Header Type: NNI IMA Max. Diff. Dly: 200 msec.
VPI Address: 1 IMA Clock Mode: CTC
Routing Cost: 10 Deroute delay time: 0 seconds
Idle code: 54 hex VC Shaping: No
Restrict PCC traffic: No VPC Conns disabled: No
Link type: Terrestrial
Last Command: dsptrkcnf 13.1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 13.1 Parameters:
1 Yel Alm-In/Out (D) [ 1000/ 2000] 18 Red Alm-In/Out (D) [ 1000/ 2000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 20] 20 Tx EFCN - BdataB (%) [ 20]
4 Gateway Efficiency (D) [ N/A]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP/EPD- Rx_Space (%) [ N/A] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
8 BDataA [ 80] 10 BDataA [ 60] 25 BDataA [ 80] 27 BDataA [ 60]
9 BDataB [ 80] 11 BdataB [ 60] 26 BDataB [ 80] 28 BDataB [ 60]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 27] 15 BDataA [10000] 29 rt-VBR [ 26] 32 BDataA [10000]
13 Non TS [ 37] 16 BDataB [10000] 30 Non TS [ 36] 33 BDataB [10000]
14 TS [ 1000] 17 HighPri[ 1000] 31 TS [ 1000] 34 HighPri[ 1000]
Rx Queue Depth(D) Tx Queue Depth(D) Rx EFCN (%) Tx EFCN (%)
35 CBR [ 600] 38 CBR [ 600]
36 nrt-VBR[ 5000] 39 nrt-VBR[ 5000]
37 ABR [20000] 40 ABR [20000] 47 ABR [ 20] 48 ABR [ 20]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
41 CBR [ 80] 44 CBR [ 60] 49 CBR [ 80] 52 CBR [ 60]
42 nrt-VBR[ 80] 45 nrt-VBR[ 60] 50 nrt-VBR[ 80] 53 nrt-VBR[ 60]
43 ABR [ 80] 46 ABR [ 60] 51 ABR [ 80] 54 ABR [ 60]
This Command: cnftrkparm 13.1
mulder TRM StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 13.1(4) Config E1/119 [17962 cps] UXM slot:13
Line DS-0 map: 1-15,17-31 Line coding: HDB3
IMA Group Member(s): 1-4 Line recv impedance: 120 ohm
Retained links: 4 HCS Masking: Yes
Transmit Trunk Rate: 17962 cps Payload Scramble: Yes
Rcv Trunk Rate: 17962 cps Connection Channels: 256
Pass sync: Yes Gateway Channels: 200
Loop clock: No Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Statistical Reserve: 600 cps IMA Protocol Option: Enabled
Header Type: NNI IMA Max. Diff. Dly: 200 msec.
VPI Address: 1 IMA Clock Mode: CTC
Routing Cost: 10 Deroute delay time: 0 seconds
Idle code: 54 hex VC Shaping: No
Restrict PCC traffic: No VPC Conns disabled: No
Link type: Terrestrial
Last Command: dsptrkcnf 13.1
mulder TRM StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 13.1(4) Parameters:
1 Yel Alm-In/Out (D) [ 1000/ 2000] 18 Red Alm-In/Out (D) [ 1000/ 2000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 20] 20 Tx EFCN - BdataB (%) [ 20]
4 Gateway Efficiency (D) [ N/A]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP/EPD- Rx_Space (%) [ N/A] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
8 BDataA [ 80] 10 BDataA [ 60] 25 BDataA [ 80] 27 BDataA [ 60]
9 BDataB [ 80] 11 BdataB [ 60] 26 BDataB [ 80] 28 BDataB [ 60]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 101] 15 BDataA [10000] 29 rt-VBR [ 100] 32 BDataA [10000]
13 Non TS [ 148] 16 BDataB [10000] 30 Non TS [ 147] 33 BDataB [10000]
14 TS [ 1000] 17 HighPri[ 1000] 31 TS [ 1000] 34 HighPri[ 1000]
Rx Queue Depth(D) Tx Queue Depth(D) Rx EFCN (%) Tx EFCN (%)
35 CBR [ 600] 38 CBR [ 600]
36 nrt-VBR[ 5000] 39 nrt-VBR[ 5000]
37 ABR [20000] 40 ABR [20000] 47 ABR [ 20] 48 ABR [ 20]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
41 CBR [ 80] 44 CBR [ 60] 49 CBR [ 80] 52 CBR [ 60]
42 nrt-VBR[ 80] 45 nrt-VBR[ 60] 50 nrt-VBR[ 80] 53 nrt-VBR[ 60]
43 ABR [ 80] 46 ABR [ 60] 51 ABR [ 80] 54 ABR [ 60]
This Command: cnftrkparm 13.1
mulder TN StrataCom IGX 8420 9.2.33 Date/Time Not Set
TRK 11.1 Config T1/24 [3622 cps] UXM slot:11
IMA Group Member(s): 1 Line coding: B8ZS
Retained links: 1 Line cable type: ABAM
Transmit Trunk Rate: 3622 cps Line cable length: 0-131 ft.
Rcv Trunk Rate: 3622 cps HCS Masking: Yes
Pass sync: Yes Payload Scramble: No
Loop clock: No Connection Channels: 256
Statistical Reserve: 600 cps Gateway Channels: 200
Header Type: NNI Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
VPI Address: 1 IMA Protocol Option: Disabled
Routing Cost: 10 IMA Max. Diff. Dly: 200 msec.
Idle code: 7F hex IMA Clock Mode: CTC
Restrict PCC traffic: No Deroute delay time: 0 seconds
Link type: Terrestrial VC Shaping: No
Line framing: ESF VPC Conns disabled: No
Last Command: dsptrkcnf 11.1
mulder TN StrataCom IGX 8420 9.2.33 Date/Time Not Set
TRK 11.1 Parameters:
1 Yel Alm-In/Out (D) [ 600/ 600] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 20] 20 Tx EFCN - BdataB (%) [ 20]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP/EPD- Rx_Space (%) [ N/A] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
8 BDataA [ 80] 10 BDataA [ 60] 25 BDataA [ 80] 27 BDataA [ 60]
9 BDataB [ 80] 11 BdataB [ 60] 26 BDataB [ 80] 28 BDataB [ 60]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 22] 15 BDataA [10000] 29 rt-VBR [ 21] 32 BDataA [10000]
13 Non TS [ 30] 16 BDataB [10000] 30 Non TS [ 28] 33 BDataB [10000]
14 TS [ 1000] 17 HighPri[ 1000] 31 TS [ 1000] 34 HighPri[ 1000]
Rx Queue Depth(D) Tx Queue Depth(D) Rx EFCN (%) Tx EFCN (%)
35 CBR [ 600] 38 CBR [ 600]
36 nrt-VBR[ 5000] 39 nrt-VBR[ 5000]
37 ABR [20000] 40 ABR [20000] 47 ABR [ 20] 48 ABR [ 20]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
41 CBR [ 80] 44 CBR [ 60] 49 CBR [ 80] 52 CBR [ 60]
42 nrt-VBR[ 80] 45 nrt-VBR[ 60] 50 nrt-VBR[ 80] 53 nrt-VBR[ 60]
43 ABR [ 80] 46 ABR [ 60] 51 ABR [ 80] 54 ABR [ 60]
This Command: cnftrkparm 11.1
mulder TN StrataCom IGX 8420 9.2.33 Date/Time Not Set
TRK 11.1(4) Config T1/95 [14339 cps] UXM slot:11
IMA Group Member(s): 1-4 Line coding: B8ZS
Retained links: 4 Line cable type: ABAM
Transmit Trunk Rate: 14339 cps Line cable length: 0-131 ft.
Rcv Trunk Rate: 14339 cps HCS Masking: Yes
Pass sync: Yes Payload Scramble: No
Loop clock: No Connection Channels: 256
Statistical Reserve: 600 cps Gateway Channels: 200
Header Type: NNI Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
VPI Address: 1 IMA Protocol Option: Enabled
Routing Cost: 10 IMA Max. Diff. Dly: 200 msec.
Idle code: 7F hex IMA Clock Mode: CTC
Restrict PCC traffic: No Deroute delay time: 0 seconds
Link type: Terrestrial VC Shaping: No
Line framing: ESF VPC Conns disabled: No
Last Command: dsptrkcnf 11.1
mulder TN StrataCom IGX 8420 9.2.33 Date/Time Not Set
TRK 11.1(4) Parameters:
1 Yel Alm-In/Out (D) [ 600/ 600] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 20] 20 Tx EFCN - BdataB (%) [ 20]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP/EPD- Rx_Space (%) [ N/A] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
8 BDataA [ 80] 10 BDataA [ 60] 25 BDataA [ 80] 27 BDataA [ 60]
9 BDataB [ 80] 11 BdataB [ 60] 26 BDataB [ 80] 28 BDataB [ 60]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 81] 15 BDataA [10000] 29 rt-VBR [ 80] 32 BDataA [10000]
13 Non TS [ 118] 16 BDataB [10000] 30 Non TS [ 117] 33 BDataB [10000]
14 TS [ 1000] 17 HighPri[ 1000] 31 TS [ 1000] 34 HighPri[ 1000]
Rx Queue Depth(D) Tx Queue Depth(D) Rx EFCN (%) Tx EFCN (%)
35 CBR [ 600] 38 CBR [ 600]
36 nrt-VBR[ 5000] 39 nrt-VBR[ 5000]
37 ABR [20000] 40 ABR [20000] 47 ABR [ 20] 48 ABR [ 20]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
41 CBR [ 80] 44 CBR [ 60] 49 CBR [ 80] 52 CBR [ 60]
42 nrt-VBR[ 80] 45 nrt-VBR[ 60] 50 nrt-VBR[ 80] 53 nrt-VBR[ 60]
43 ABR [ 80] 46 ABR [ 60] 51 ABR [ 80] 54 ABR [ 60]
This Command: cnftrkparm 11.1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 14.1 Config T3/636 [96000 cps] UXM slot:14
Transmit Trunk Rate: 96000 cps Payload Scramble: No
Rcv Trunk Rate: 96000 cps Connection Channels: 256
Pass sync: Yes Gateway Channels: 200
Loop clock: No Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Statistical Reserve: 1000 cps Deroute delay time: 0 seconds
Header Type: NNI VC Shaping: No
VPI Address: 1 VPC Conns disabled: No
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Line framing: PLCP
Line cable length: 0-225 ft.
HCS Masking: Yes
Last Command: dsptrkcnf 14.1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 14.1 Parameters:
1 Yel Alm-In/Out (D) [ 2500/ 15000] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 20] 20 Tx EFCN - BdataB (%) [ 20]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP/EPD- Rx_Space (%) [ N/A] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
8 BDataA [ 80] 10 BDataA [ 60] 25 BDataA [ 80] 27 BDataA [ 60]
9 BDataB [ 80] 11 BdataB [ 60] 26 BDataB [ 80] 28 BDataB [ 60]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 532] 15 BDataA [10000] 29 rt-VBR [ 532] 32 BDataA [10000]
13 Non TS [ 795] 16 BDataB [10000] 30 Non TS [ 795] 33 BDataB [10000]
14 TS [ 1000] 17 HighPri[ 1000] 31 TS [ 1000] 34 HighPri[ 1000]
Rx Queue Depth(D) Tx Queue Depth(D) Rx EFCN (%) Tx EFCN (%)
35 CBR [ 600] 38 CBR [ 600]
36 nrt-VBR[ 5000] 39 nrt-VBR[ 5000]
37 ABR [20000] 40 ABR [20000] 47 ABR [ 20] 48 ABR [ 20]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
41 CBR [ 80] 44 CBR [ 60] 49 CBR [ 80] 52 CBR [ 60]
42 nrt-VBR[ 80] 45 nrt-VBR[ 60] 50 nrt-VBR[ 80] 53 nrt-VBR[ 60]
43 ABR [ 80] 46 ABR [ 60] 51 ABR [ 80] 54 ABR [ 60]
This Command: cnftrkparm 14.1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 15.1 Config E3/530 [80000 cps] UXM slot:15
Transmit Trunk Rate: 80000 cps Payload Scramble: Yes
Rcv Trunk Rate: 80000 cps Connection Channels: 256
Pass sync: Yes Gateway Channels: 200
Loop clock: No Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Statistical Reserve: 1000 cps Deroute delay time: 0 seconds
Header Type: NNI VC Shaping: No
VPI Address: 1 VPC Conns disabled: No
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Line framing: HEC
Line cable length: 0-225 ft.
HCS Masking: Yes
Last Command: dsptrkcnf 15.1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 15.1 Parameters:
1 Yel Alm-In/Out (D) [ 2500/ 15000] 18 Red Alm-In/Out (D) [ 2500/ 15000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 20] 20 Tx EFCN - BdataB (%) [ 20]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP/EPD- Rx_Space (%) [ N/A] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
8 BDataA [ 80] 10 BDataA [ 60] 25 BDataA [ 80] 27 BDataA [ 60]
9 BDataB [ 80] 11 BdataB [ 60] 26 BDataB [ 80] 28 BDataB [ 60]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 443] 15 BDataA [10000] 29 rt-VBR [ 443] 32 BDataA [10000]
13 Non TS [ 662] 16 BDataB [10000] 30 Non TS [ 662] 33 BDataB [10000]
14 TS [ 1000] 17 HighPri[ 1000] 31 TS [ 1000] 34 HighPri[ 1000]
Rx Queue Depth(D) Tx Queue Depth(D) Rx EFCN (%) Tx EFCN (%)
35 CBR [ 600] 38 CBR [ 600]
36 nrt-VBR[ 5000] 39 nrt-VBR[ 5000]
37 ABR [20000] 40 ABR [20000] 47 ABR [ 20] 48 ABR [ 20]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
41 CBR [ 80] 44 CBR [ 60] 49 CBR [ 80] 52 CBR [ 60]
42 nrt-VBR[ 80] 45 nrt-VBR[ 60] 50 nrt-VBR[ 80] 53 nrt-VBR[ 60]
43 ABR [ 80] 46 ABR [ 60] 51 ABR [ 80] 54 ABR [ 60]
This Command: cnftrkparm 15.1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 16.1 Config OC3 [353207cps] UXM slot:16
Transmit Trunk Rate: 353208 cps Connection Channels: 256
Rcv Trunk Rate: 353207 cps Gateway Channels: 200
Pass sync: Yes Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Loop clock: No Frame Scramble: Yes
Statistical Reserve: 1000 cps Deroute delay time: 0 seconds
Header Type: NNI VC Shaping: No
VPI Address: 1 VPC Conns disabled: No
Routing Cost: 10
Idle code: 7F hex
Restrict PCC traffic: No
Link type: Terrestrial
Line framing: STS-3C
HCS Masking: Yes
Payload Scramble: Yes
Last Command: dsptrkcnf 16.1
mulder TN StrataCom IGX 8420 9.2.34 Date/Time Not Set
TRK 16.1 Parameters:
1 Yel Alm-In/Out (D) [ 2500/ 10000] 18 Red Alm-In/Out (D) [ 2500/ 10000]
2 Rx Max Age - rt-VBR (D) [ 20] 19 Tx Max Age - rt-VBR (D) [ 20]
3 Rx EFCN - BdataB (D) [ 20] 20 Tx EFCN - BdataB (%) [ 20]
4 Gateway Efficiency (D) [ 2.0]
5 EFCN - Rx Space (D) [ N/A] Tx Age Step2 (D) Tx Age Step (D)
6 Low CLP/EPD- Rx_Space (%) [ N/A] 21 BDataA [ N/A] 23 BDataA [ N/A]
7 High CLP - Rx_Space (%) [ N/A] 22 BDataB [ N/A] 24 BDataB [ N/A]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
8 BDataA [ 80] 10 BDataA [ 60] 25 BDataA [ 80] 27 BDataA [ 60]
9 BDataB [ 80] 11 BdataB [ 60] 26 BDataB [ 80] 28 BDataB [ 60]
Receive Queue Depth (D) Transmit Queue Depth (D)
12 rt-VBR [ 1952] 15 BDataA [10000] 29 rt-VBR [ 1952] 32 BDataA [10000]
13 Non TS [ 2925] 16 BDataB [10000] 30 Non TS [ 2925] 33 BDataB [10000]
14 TS [ 1000] 17 HighPri[ 1000] 31 TS [ 1000] 34 HighPri[ 1000]
Rx Queue Depth(D) Tx Queue Depth(D) Rx EFCN (%) Tx EFCN (%)
35 CBR [ 600] 38 CBR [ 600]
36 nrt-VBR[ 5000] 39 nrt-VBR[ 5000]
37 ABR [20000] 40 ABR [20000] 47 ABR [ 20] 48 ABR [ 20]
Rx High CLP (%) Rx Low CLP/EPD(%) Tx High CLP (%) Tx Low CLP/EPD(%)
41 CBR [ 80] 44 CBR [ 60] 49 CBR [ 80] 52 CBR [ 60]
42 nrt-VBR[ 80] 45 nrt-VBR[ 60] 50 nrt-VBR[ 80] 53 nrt-VBR[ 60]
43 ABR [ 80] 46 ABR [ 60] 51 ABR [ 80] 54 ABR [ 60]
This Command: cnftrkparm 16.1
For service and support for a product purchased from a reseller, contact the reseller. Resellers offer a wide variety of Cisco service and support programs, which are described in the section "Service and Support" in the information packet that shipped with your chassis.
![]() |
Note If you purchased your product from a reseller, you can access Cisco Connection Online (CCO) as a guest. CCO is Cisco Systems' primary, real-time support channel. Your reseller offers programs that include direct access to CCO's services. |
For service and support for a product purchased directly from Cisco, use CCO.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
![]() |
Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.![]() |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Aug 18 11:18:13 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.