cc/td/doc/product/wanbu/9_1/nms
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Bulk Statistics File Format

Bulk Statistics File Format

Cisco StrataView Plus (SV+) collects statistics from IPX, IGX, BPX, FastPAD, DNS, and AXIS nodes using the Trivial File Transfer Protocol (TFTP).

Cisco SV+ issues a get request and the node responds by transmitting the statistics, in bulk, to a statistics collection file.

The statistic values received are used to update the Cisco SV+ database. Knowing the file name and format, you can parse the file to extract the value of each statistic type.

File Name

Each statistics collection file received from a node is uniquely identified in Cisco SV+ using the following filename format:

<Nodename.mmddyyhhmm>

where <Nodename> is the name of the node from which the statistics were collected and <mmddyyhhmm> is the date and time (GMT) the statistics were collected.

File Format

As indicated in the lists of statistic types in Chapter 3, "Database Definition", each type of statistic collected in an IPX/BPX/IGX/AXIS network is categorized under a major grouping known by an object type name and an object type number, and a minor grouping known as a sub-type. Within the sub-type, the statistic has a statistic type number.

For example, the statistic "ATM Cell Header HEC Errors" has an object type name of IPX-ATM, an object type of 2, a sub-type of 1, and a statistic type of 45. This combination of groups and type numbers uniquely identify a particular type of statistic.

The format of the statistics collection file consists of a fixed-length header and a sequential string of statistics identified by their object type, sub-type, and statistic type.


Table A-1: Format of Statistics Collection File
Field Description Field Size
Fixed Header Section

Domain number of node.

1 byte

Node number.

1 byte

Release number (example, 725a for release 7.2.5.A).

4 bytes

Node type.

1 byte

Status byte.

2 bytes

Peak flag (1 = enabled, 0 = disabled).

1 byte

Bucket interval.

1 byte

Number of Object types. (always FF [255] when node type is MGX 8220)

1 byte

Data Dependent Section

Object type identifier.

1 byte

Number of Object sub-types.

1 byte

Object Sub-type identifier.

1 byte

Number of instances of key.

2 bytes

Key instance.

variable length*

Stat type count.

1 byte

Stat type.

1 byte

Number of buckets.

1 byte

Stat value (reverse chronological order).

5 bytes

Peak value (1st bucket = file time stamp).

5 bytes

Repeat Stat type, Stat value, and Peak value for number of buckets.

n bytes

Repeat Object Sub-type identifier section.

n bytes

Repeat Object type section.

n bytes

Checksum.

4 bytes

The Object Sub-types to Key List table depicts the keying information based upon Object Sub Type.


Table A-2: Object Sub-Type to Key List
Object Sub-type Key Field 1 Key Field 2 Key Field 3 Key Field 4 Key Field 5

IPX Frame Relay Connection

Slot

Channel

DCLI, 2 bytes

N/A

N/A

IPX Voice Connection

Slot

Channel

N/A

N/A

N/A

IPX Data Connection

Slot

Channel

N/A

N/A

N/A

ATM Connection ASI

Slot

Port

VPI, 2 bytes

VCI, 2 bytes

N/A

ATF Connection BPX Local

Slot

Port

DCLI, 2 bytes

N/A

N/A

ATF Connection IPX Local
(ATM for AIT card)

Slot

Port

DCLI, 2 bytes

N/A

N/A

FastPAD Connection (includes Voice, Switched Voice, and Data)

Slot

Port

FP slot

FP Port

N/A

FastPad Frame Relay

Slot

Port

Slot

Port

DLCI 2

FastPad ATM

Slot

Port

VPI 2

VCI 3

N/A

AXIS Frame Relay

Slot

R VCI 2

N/A

N/A

N/A

AXIS ATM

Slot

CN 2

N/A

N/A

N/A

AXIS CE

Slot

R VCI 2

N/A

N/A

N/A

ASI Line (Service interface)

Slot

Port

N/A

N/A

N/A

AXIS T1 (Service interface)

Slot

Line

N/A

N/A

N/A

AXIS ATM (Service interface)

Slot

Line

N/A

N/A

N/A

IPX Service Interface (T1/E1)

Line

N/A

N/A

N/A

N/A

IPX Trunk, includes ATM and AIT cards

Line

N/A

N/A

N/A

N/A

BPX ATM Trunk

Line

N/A

N/A

N/A

N/A

AXIS Narrowband Trunk

Slot

Line

N/A

N/A

N/A

AXIS ATM Trunk

Slot

Line

N/A

N/A

N/A

IPX Frame Relay Port

Slot

Port

N/A

N/A

N/A

ASI Port

Slot

Port

N/A

N/A

N/A

FTC Port (FastPAD)

Slot

Port

N/A

N/A

N/A

AXIS Frame Relay Port

Slot

Logical Port

N/A

N/A

N/A

AXIS ATM Port

Slot

Line

N/A

N/A

N/A

All key fields are one byte in length unless otherwise noted.