This appendix provides details on the IPX system specifications.
This appendix contains the following:
The following are general conditions applicable to the IPX 8, 16, and 32.
Operating Environment: | Operating Conditons are listed in Table A-1. |
Shock: | Withstands 10G, 10 ms. at 1/2 sine wave. |
Vibration: | Withstands 1/4 G, 20 to 500 Hz. |
Heat Transfer to Room: | IPX 16: 3600 BTUs max |
| Conditions | Limits | |
|---|---|---|
| Fahrenheit | Centigrade | |
Operating Temperature Recommended: | +40 to +100 degrees +68 to 86 degrees | +4.5 to 38 degrees +20 to +30 degrees |
Short-Term Temperature1 | +35 to +120 degrees | +1.7 to + 49 degrees |
Operating Relative Humidity | 20% to 55% non-condensing | |
Short-Term Relative Humidity | 10% to 80% non-condensing. | |
| 1Room temperature refers to conditions at a location 5 feet above the floor and 15 inches in front of the equipment. |
System Capacity: | 1 or 2 shelves, each with 16 card slots. |
Cabinet Size: | 65.6 inches (166.7 cm) high. |
Shipping Weight: | 700 pounds (318 kilos) for IPX 32 fully loaded. |
Clearance Requirement: | At least 30 inches front and rear clearance; nominal |
Power Input: | AC system: 180 to 264 VAC, 47 to 63 Hz. |
Power Requirements: | Configuration dependent - use Network Design Tool for exact requirements. For planning purposes, use: |
· AC Power | Max . Current Max. VA Max. Power IPX 16: 9.2 A 1.7 KVA 1.1 KW IPX 32: 17 A 3.1 KVA 2 KW |
· DC Power | Max . Current Max. Power IPX 16: 28 A 1.2 KW IPX 32: 50 A 2.1 KW |
Input AC Power Connector: | AC Power Distribution unit is the same for all cabinets shipped: · For North America and Japan: NEMA L6-20 Twist Clock · For Continental Europe: CEE 7/7 (Schuko) · *For Italy: CEI 23-16/VII (16-amp plug) · For United Kingdom and Ireland: BS 1263 · For Australia and New Zealand: AS 3112 · For those countries not appearing in the preceding list, use a power cord with an IEC 320 C-19 coupler for the system end, and an appropriate ground-type attachment plug at the other end in accordance with local standards. |
DC Input Connections: | DC power is the same for all IPX 16/32 cabinets shipped. DC: 3 ring lug screw terminal connectors. |
System Capacity: | 1 shelf with 8 card slots. |
System Controller: | NPC, single or redundant |
System Software: | Release 8.1 or later |
System Throughput: | 32 Mbps. |
External Clock Sources: | IPX synchronizes to the nearest, highest-stratum clock available. Any E1 or T1 circuit line, trunk, or external clock input can be used as a clock source. |
Internal to Node Source: | T1: 1.544 MHz, ± 50 Hz (Stratum 4). |
Cabinet Size: | 24.5 inches (62.2 cm) high. |
Shipping Weight: | 122 pounds (55.5 kgs) fully loaded. |
Clearance Requirement: | At least 30 inches front and rear clearance; nominal |
Voice Channel Interface: | 24-channel T1 (D4 format). |
Voice Compression | 32/24/16 Kbps ADPCM (Rel. 6 systems). |
Compression Algorithm: | CCITT G.721, G.723, G.726 (Rel. 6 systems). |
PCM Encoding Types: | Accommodates µ-Law or A-Law encoding, |
Channel Gain Control: | -8 dB to +6 dB. |
Signaling Modes: | T1: Robbed bit or CCS (ISDN). |
Signaling Conditioning: | Various make-busy and forced idle routines during circuit alarm can be specified on a per-channel basis. |
Quantizing Distortion Added: | 2.5 Quantizing Distortion Units (QDU)s with 32 Kbps ADPCM over 1 hop plus 0.7 (QDU)s with Digital Loss PAD (µ-law or A-Law). |
Sync. Data Interfaces: | RS-232C/D, RS-449/422, V.24, X.21, and V.35 |
Sync. Data Rates (SDP): | 2.4 Kbps to 1.344 Mbps. |
Low-Speed Data Rates: | 2.4 to 19.2 Kbps per LDP port. |
Ports per card: | LDI: 4 or 8. |
Control Leads Supported: | SDI: Per interface standards. |
Control Lead Sync | Control leads are sampled every 50 ms. and changes will normally follow data within 100 to 1000 msec. Fast EIA lead will be within 1 byte. |
DS0A Interface: | Superrate, 56 Kbps to 512 Kbps (8 DS0s) per port. |
Data Clocking: | Synchronous and isochronous clocking. |
Pleisochronous | ± 2 percent of nominal data rate. |
Line Rate: | 1.544 Mbps, ± 50 bps (± 200 bps VCO lock range). |
Line Code: | Bipolar AMI or B8ZS. |
Framing Formats: | Fractional T1, adjacent or alternating channels. |
Signal Level: | DSX-1 compatible. |
Line Impedance: | Terminated = 100 ohms nominal. |
Base-to-Peak Height: | 6V, ± 0.6V. |
Minimum Pulse Density: | Zero code suppression, either LSB or MSB. |
Frame Format: | D3/D4 superframe or ESF. |
VF Signalling: | Robbed bit D4 with A and B bits, ESF with A, B, C, and D bits. |
Max. Line Lengths: | Up to 655 feet with equalizers using ABAM cable. |
Jitter Transfer: | Meets Bell PUB 62411 specifications. |
Jitter Tolerance: | Meets ANSI standards and Bell PUB 62411 |
Connector: | DB 15 female. |
Line Rate: | 2.048 Mbps, ± 50 bps (± 200 bps VCO lock range). |
Line Code: | Bipolar AMI or HDB3. |
Line Impedance: | 120 ohms, balanced or |
Minimum Pulse Density: | Zero code suppression via HDB3 coding. |
Frame Format: | Unframed, 32-channel (G.703). |
VF Signalling: | CAS or CCS. |
Max. Line Lengths: | Up to 50 meters with equalizers using shielded cable. |
Jitter: | Meets G.823. |
Electrical Interface: | Complies with G.703 Specification. |
Connector: | DB 15 female or BNC. |
Line Code: | B3ZS. |
Line Rate: | 44.736 Mbps ± 20 ppm. |
Clock Source Mode: | Internal (Asynchronous). |
Signal Level: | DSX-3. |
Framing Formats: | M13 mode. |
Alarms Sent: | AIS. |
Alarms Received: | AIS. |
Line Errors Counted: | BPV. |
Receiver Input Impedance: | Terminated = 75 ohms. |
Transmission Modes: | Point-to-Point or Drop and Insert. |
Jitter: | Meets ACCUNET T45 specification (Pub 54014). |
Connector: | 75 ohm BNC. |
Max. Line Lengths: | 450 ft. (137 m) using specified cable |
Indicators: | RED Alarm. |
Line Rate: | 34.368 Mbps ± 20 ppm, asynchronous. |
Line Code: | HDB3. |
Clock Source Mode: | Internal (Asynchronous). |
Signal Level: | ITU-T G.703 |
Framing Formats: | ITU-T G.804, G.832, |
Alarms Processed: | AIS. |
| LOS. |
| Remote Alarm Indication. |
| Loss Of Framing. |
Line Errors Counted: | BPV. |
| Parity Bit Errors. |
Receiver Input Impedance: | 75 ohms unbalanced. |
Transmission Modes: | Point-to-Point or Drop and Insert. |
Jitter: | per ITU-T G.823. |
Connector: | 75 ohm BNC. |
Max. Line Lengths: | 450 ft. (137 meters) |
Indicators: |
|
| RED Alarm. |
| YELLOW Alarm. |
| LOS. |
| AIS. |
Type of Service: | Permanent Virtual Circuit (PVC). |
Data Interface: | Per CCITT I.122 and ANSI T1/S1 Standards. |
Data Transfer Protocol: | LAP-D frame level core functions. |
Input Data Format: | High Level Data Link (HDLC) protocol. |
Input Data Frame Length: | Up to 4096 bytes max. |
Frame Integrity Check: | Frame Check Sequence and CRC check of data frame. If CRC fails, data frame is discarded at receiving node. |
Input Data Rate: | 56 Kbps to 2.048 Mbps. (Max. rate available only with one of four ports/card active). |
No. of Ports per Card: | 4 |
No. of PVCs per Port: | 252 per FR card, distributed in any combination. |
Port Electrical Interface: | CCITT V.35. IPX can act as a DCE or DTE for direction of control leads and timing. |
Data Clocking: | Normal or looped. |
Virtual Circuit Identifier: | Data Link Connection Identifier (DLCI). |
Control Protocol: | Local Management Interface with XON/XOFF type flow control. IPX sets FECN and BECN bits in frame relay frame. |
Bundled Connections: | 252 virtual circuits per card. |
Billing Time Accuracy: | Upon request from user device, IPX will provide GMT from any node accurate to within 1 second. |
External Clock Sources: | IPX synchronizes to the nearest, highest-stratum clock available. Any E1 or T1 l circuit line, trunk, or optional external clock input can be used as a clock source. |
Internal to Node Source: | T1: 1.544 MHz, ± 50 Hz (Stratum 4). |
Clocking Hierarchy: | Dynamic primary, secondary, and tertiary clocking. |
Network Control Terminal: | Cisco StrataView Plus workstation and software required for graphical display of network status, statistics gathering and display, automatic downloading of software, and network management including Frame Relay connection management. |
Control Terminal: | SV+ telnent session, or DEC VT100, WYSE 85, Televideo 970 or equivalent terminal for basic system configuring. |
Remote Alarm Reporting: | Autodial modem connects to one of two control ports on each IPX nodes for automatic reporting of network alarms. |
Remote Diagnostics: | Auto-answer modem connects to one of two control ports on each IPX node for remote diagnostic access by Customer Service or other authorized personnel. |
Network Control Ports: | Two ports per node, RS 232C interface. |
Alarm Notification: | Status of all trunks and nodes in network distributed to and stored by each individual node. Reported to Cisco StrataView Plus terminal at connecting node. |
External Alarms: | Meets Bellcore Compatibility Bulletin #143 and AT&T Technical Reference PUB 43801 DS1 (T1) facility alarm requirements when equipped with DTI group. |
Indicators and Controls: | Active and Fail lights on all cards and power supplies. |
|
|