Table of Contents
Introduction
This manual describes the features and functions of Release 4.0 of the Cisco MGX 8220 edge concentrator. (See Figure 1-1.)
Figure 1-1: MGX 8220 Shelf
The MGX 8220 shelf is designed on the philosophy that large scale deployment of narrowband and medium-band services is best handled using an ATM infrastructure. In fact, support of these services can, by itself, justify an ATM infrastructure. This same infrastructure can then be used to provide broadband services when and where needed.
The MGX 8220 shelf is an adjunct shelf to the Cisco BPX® 8600 series wide-area switch. Architecturally it provides:
- A means for flexibly providing many narrowband and/or medium-band ATM and non-ATM service interfaces without consuming BPX switch slots.
- Conversion of non-ATM traffic streams to and from ATM traffic streams using Adaptation Layer standards.
- A means for concentrating the traffic from the narrowband and/or medium-band interfaces onto the broadband ATM ports of the BPX switch.
The MGX 8220 shelf is a flexible standards-based service access platform. The MGX 8220 shelf can support a wide range of services over narrowband and mid-band user interfaces, mapping all the service traffic to and from ATM, based upon standardized interworking methods. The aggregated traffic is sent/received over an ATM interface to an ATM switch (BPX switch), using up only a single port on the ATM switch.
Release 4.0 of the MGX 8220 shelf supports up to 80 channelized or non-channelized T1 and E1 interfaces on a single shelf providing support for Frame Relay UNI and NNI; ATM UNI, NNI, and FUNI; Frame Relay to ATM network interworking; Frame Relay to ATM service interworking and circuit emulation services. Using a new Service Resource Module (SRM), multiple T1 interfaces can be supported on physical T3 lines. Release 4.0 of the MGX 8220 shelf also supports the use of Inverse Multiplexing for ATM (IMA) to provide ATM trunking below T3/E3.
The system's modular, software-based architecture enables it to support these and other additional user services in the future, through downloadable software upgrades or new hardware modules.
All user information received by the MGX 8220 interfaces is converted into 53-byte ATM cells, using standard ATM Adaptation Layers (AALs) for transport over the ATM backbone network. Cell segmentation and reassembly (SAR) and other adaptation functions are distributed to each interface module to eliminate system bottlenecks.
- For Circuit Emulation Services AAL1 is used.
- For Frame Relay (FR to ATM network interworking) AAL5 and FR-SSCS (Frame Relay Service Specific Convergence Sublayer) are used.
- For Frame Relay to ATM service interworking, both transparent and translation modes are supported to map FR to native ATM AAL5.
- For Frame Forwarding AAL5 is used.
Each MGX 8220 shelf connects to the BPX switch across a T3 or E3 ATM to a BNI module on the BPX switch or via a SONET ATM link to a BXM-155-8 port on the BPX switch. Thus, the
MGX 8220 shelf Release 4.0 supports aggregation of traffic up to 80 T1 or E1 access ports or up to 1240 64-Kbps subscribers, onto a single T3, E3, or OC-3c trunk, using only a single port on the
BPX switch.
The MGX 8220 shelf should normally be collocated with the BPX switch. Figure 1-2 shows how the MGX 8220 shelf usage is envisioned in Release 4.0.
Figure 1-2: MGX 8220/BPX Switch Relationship
For remote locations with limited bandwidth needs, the MGX 8220 shelf can be remotely located from the BPX switch using IMA trunk machines as shown in Figure 1-3.
Figure 1-3: Remote MGX 8220 Configuration
The following subsections provide an overview of the MGX 8220 shelf, the Release 4.0 cards, and management capabilities. In-depth details are provided in subsequent chapters.
Physically, the MGX 8220 shelf consists of cards in a 19 inch rack mountable shelf.
The shelf can be powered either from a -48VDC source or from a 220V AC source. The DC version includes DC power entry modules that can be mounted in the shelf. The AC version requires an external rack mounted, AC Power Module. Both versions require a rack mounted cooling assembly. Multiple MGX 8220 shelves can be mounted in the same rack sharing power and cooling assemblies.
The MGX 8220 shelf contains 16 slots. Each slot can accommodate a front card and a back card. The front row is used for function modules, cards that perform more complex functions within the unit (for example, frame relay to ATM conversion). The back row is used for line modules, cards that provide interfaces to one or more transmission lines connected to the MGX 8220 shelf (for example, the trunk line to the BPX switch or an RS-232 line to a control terminal).
Unless a service module uses the SRM 3T3 distribution bus, MGX 8220 cards are installed as a pair consisting of a front card (function module) and a matching back card (line module) in the same slot, except for the SRM-T1E1 card which only has a front card. Communication between slots is achieved through buses in the shelf backplane.
Release 4.0 consists of the following module pairs:
- MGX 8220 Shelf Controller(ASC)
This is a pair of cards providing overall control of the shelf and providing line interfaces to maintenance and control ports which are used for user configuration and management of the shelf.
- Broadband Network Module (BNM-T3)
This is a pair of cards which together provide the interface to the attached BPX switch over a
T3 ATM interface.
- Broadband Network Module (BNM-E3)
This is a pair of cards which together provide the interface to the attached BPX switch over a
E3 ATM interface.
- Broadband Network Module (BNM-155)
This is a pair of cards which together provide the interface to the attached BPX switch over a SONET ATM interface.
- Frame Service Module for T1 (FRSM-4T1)
This card provides interfaces for up to four T1 lines, each of which can support one 56 kbps or one Nx64 kbps FR-UNI, FR-NNI port, ATM-FUNI, or a Frame Forwarding port.
- Frame Service Module for T1 (FRSM-8T1)
This card provides interfaces for up to eight T1 lines, each of which can support one 56 kbps or one Nx64 kbps FR-UNI, FR-NNI port, ATM-FUNI, or a Frame Forwarding port.
- Frame Service Module for T1 channelized (FRSM-4T1-C)
This card provides interfaces for up to four T1 lines, each of which can support multiple (up to 24) 56 kbps or Nx64 kbps FR-UNI, FR-NNI, ATM-FUNI, or a Frame Forwarding port.
- Frame Service Module for T1 channelized (FRSM-8T1-C)
This card provides interfaces for up to eight T1 lines, each of which can support multiple (up to 24) 56 kbps or Nx64 kbps FR-UNI, FR-NNI, ATM-FUNI, or Frame Forwarding port.
- Frame Service Module for E1 (FRSM-4E1)
This card provides interfaces for up to four E1 lines, each of which can support one 56 kbps or one Nx64 kbps FR-UNI, FR-NNI, ATM-FUNI, or Frame Forwarding port.
- Frame Service Module for E1 (FRSM-8E1)
This card provides interfaces for up to eight E1 lines, each of which can support one 56 kbps or one Nx64 kbps FR-UNI, FR-NNI, ATM-FUNI, or Frame Forwarding port.
- Frame Service Module for E1, channelized (FRSM-4E1-C)
This card provides interfaces for up to four E1 channelized frame relay lines, each of which can support multiple (up to 31) 56 kbps or Nx64 kbps FR-UNI, FR-NNI, ATM-FUNI, or Frame Forwarding port.
- Frame Service Module for E1, channelized (FRSM-8E1-C)
This card provides interfaces for up to eight E1 channelized frame relay lines, each of which can support multiple (up to 31) 56 kbps or Nx64 kbps FR-UNI, FR-NNI, ATM-FUNI, or Frame Forwarding port.
- ATM UNI Service Module for T1 (AUSM-4T1)
This card provides interfaces for up to four T1 lines, each of which can support one T1 ATM UNI or ATM NNI.
- ATM UNI Service Module for E1 (AUSM-4E1)
This card provides interfaces for up to four E1 lines, each of which can support one E1 ATM UNI or ATM NNI.
- ATM UNI Service Module for T1 (AUSM-8T1)
This card provides interfaces for up to eight T1 lines, each of which can support one T1 ATM UNI or ATM NNI plus additional support for IMA.
- ATM UNI Service Module for E1 (AUSM-8E1)
This card provides interfaces for up to eight E1 lines, each of which can support one E1 ATM UNI or ATM NNI plus additional support for IMA.
- Circuit Emulation Service Module for T1 (CESM-4T1)
This card provides interfaces for up to four T1 lines, each of which is a 1.544 Mbps unstructured synchronous data stream.
- Circuit Emulation Service Module for E1 (CESM-4E1)
This card provides interfaces for up to four E1 lines, each of which is a 2.048 Mbps unstructured synchronous data stream.
- Inverse Multiplexing for ATM Trunk Module---T3 to T1 (IMATM-8T1)
This card acts as an extension of the BPX BNI card and permits the BPX ATM trunk to be used over multiple (up to 8) T1 lines instead of a single T3 line.
- Inverse Multiplexing for ATM Trunk Module---E3 to E1 (IMATM-8E1)
This card acts as an extension of the BPX BNI card and permits the BPX ATM trunk to be used over multiple (up to 8) E1 lines instead of a single E3 line.
- Service Resource Module (SRM-T1E1)
This card provides loopback and bit error rate testing (BERT) functions and 1:N redundancy for the service modules.
- Service Resource Module (SRM-3 T3)
This card provides loopback and bit error rate testing (BERT) functions and 1:N redundancy for the service modules. Three T3 service lines are also provided to carry multiple T1 service lines which are then mapped to T1 based service module slots and ports in the MGX 8220 shelf.
The ASC and the BNM modules must always be present in an MGX 8220 shelf and are referred to as the core modules. The MGX 8220 shelf in Release 4.0 supports redundant core modules where one ASC/BNM set is an active set and a second ASC/BNM is a standby set. In the event of a malfunction, the standby set automatically takes over as the active set. The SRM is optional. If present, it is part of the core card set, with switchover to the standby upon a malfunction of the active BNM or ASC.
The functions and operation of the MGX 8220 shelf are achieved through downloaded firmware. The firmware controls the overall operation of the shelf and responds to configuration and other commands received from a user terminal or workstation. The MGX 8220 shelf has a command repertoire of over 60 user commands which are used to configure and display the various operational parameters of the shelf.
The current status and configuration parameters of the MGX 8220 modules are maintained in a Management Information Base (MIB) which is updated by the firmware as changes in status and configuration occur. The MIB can be interrogated using SNMP commands.
Most of the functions of the MGX 8220 shelf in Release 4.0 can be effected through the graphical user interface provided in StrataView Plus Release 8.4.
The ASC module includes three ports for user input of management commands. A further means of management access is provided in-band over the ATM trunk.
The maintenance port is a simple RS-232 port for direct connection to an alpha-numeric terminal into which the user can type commands through a Command Line Interface (CLI).
The control port (SLIP protocol only), the LAN (Ethernet) port and the in-band ATM connection all support the CLI (via Telnet), TFTP and SNMP protocols for communicating with the MGX 8220 shelf.
This section provides a very brief description of the new MGX 8220 shelf features that have been added since Release 3:
- A new Broadband Network Module is available which supports SONET 155 Mbit/s trunking to the BPX switch.
- The Frame Service Modules (FRSM) now support 4 and 8 ports per card versions.
- AUSM support for eight T1 or E1 ports per card.
- The ATM UNI Service Module (AUSM) now supports a number of new features including SRM BERT support, enhanced CAC (Connection Admission Control) and Virtual Path Connection capability.
- The new optional SRM (Service Resource Module) which provides support for 3 T3 service ports in addition to loopback and BERT testing of lines and ports and 1:N redundancy for service modules as a feature license. Supports bulk distribution of T1 circuits.
- UNI and NNI cell formats have been added to the STI cell format as available modes for communication with the BPX switch.
- A graceful upgrade procedure has been added which permits upgrading firmware from an earlier version without the need to reset the shelf.
- CLLM is now supported for both UNI and NNI interfaces, previously CLLM was supported for NNI only.
- Standard based OAM segmented loopback cells are now supported for testcom/testdelay operations.
- IMATM8T1/8E1 now supports multiple trunking.
- FRSM-HS1 with 2 HSSI or 4 X.21 ports







Posted: Thu Feb 18 19:17:50 PST 1999
Copyright 1989-1999©Cisco Systems Inc.