This chapter describes the StrataView Plus database column and row structure for each of the database tables. A description of how to interpret the contents of each field is included.

Structure

The database is an Informix SQL database and consists of the following 38 tables.


Table 3-1: Table of Tables
Table Description

SV_SYSTEM

Contains StrataView name and system parameters

SV_VERSION

Contains StrataView release number and date

NETWORK

Contains ID and name of each IPX/BPX network in the database

NODE

Contains name and status of each node in each network

PACKET_LINE

Contains name, topology, technical details and status of each packet line in each network

CIRCUIT_LINE

Contains name, topology, technical details and status of each circuit line in each network

FRP

Contains name, topology, technical details and status of each frame relay port in each network

USER_CONNECTION

Contains details of each user connection in each network

CONNECTION

Contains details of each connection in each network

STAT_ENABLE

Contains details of which and what type of network statistics are to be collected

PACKET_LN_DATA

Contains packet line statistic data

CIRCUIT_LN_DATA

Contains circuit line statistic data

FRP_DATA

Contains frame relay port statistic data

CONNECTION_DATA

Contains connection statistic data

LOGICAL_CONN

Contains details of the network's logical connections

ROUTES

Contains network routing information

ATM_CONNECTION

Contains ATM connection information

ASI_LINE

Contains information about BPX ASI lines

ASI_PORT

Contains information about BPX ASI ports

FPD_CONNECTION

Contains information about FastPAD connections

FTC_PORT

Contains information about FastPAD IPX ports

FPD_NODE

Contains information about FastPAD nodes

FPD_CONN_DATA

Contains information about FastPAD statistics

ASI_LN_DATA

Contains information about ASI line statistics

ASI_PORT_DATA

Contains information about BPX ASI port statistics

FTC_PORT_DATA

Contains information about FastPAD IPX port statistics

BIS_OBJECT

Contains information about BPX Interface shelf (BIS) object statistics

SHELF

Contains information about AXIS Shelves

PERIPHERAL

Contains information about AXIS Peripherals

CARD

Contains information about AXIS Cards

PLCP

Contains information about AXIS PLCPs

AUSM_PORT

Contains information about AXIS AUSM ports

AUSM_PORT_DATA

Contains information about AUSM port statistics (8.2 or above)

CESM_CONNECTION

Contains information about CESM connections (8.2 or above)

DNS_NODE

Contains information about DNS nodes (8.2 or above)

redundantCard

Contains information about redundant cards (8.4)

lineDistribution

Contains information about line distribution (8.4)

vpRange

Contains information about VP range (8.4)

Each row in a table may be referenced (accessed) through a unique identifier which is made up of one or more fields in the row. The fields that make up the unique identifier are indicated in bold in each of the table descriptions that follow.

Data Types


Table 3-2: Data Types
Data Type
(C Format)
Data Type
(Informix Format)
Remarks

int

integer

Signed 32 bit binary integer

long

integer

Signed 32 bit binary integer

short

smallint

Signed 16 bit binary integer

char (n+1)

char (n)

Fixed length character string n bytes in length. In the C format, the length is specified as one byte longer to accommodate the terminating null character that is required in C character strings. When the actual character string is shorter than the specified number of characters, the field is filled out on the right with blanks.

date

Signed 32 bit binary integer containing the date expressed as the number of days from (or before) December 31, 1899. January 1, 1900 is day 1.

Table Definitions


Table 3-3: SV_SYSTEM
Column Name Unique Identifier Field Data Type Description

name

yes

char (8+1)

name of the SV Plus parameter

val

char (20+1)

character string including revision number of database

release

yes

char (20+1)

SV+ release number

release_date

char (32+1)

SV+ release date


Table 3-4: NETWORK
Column Name Unique Identifier Field Data Type Description

netw_id

yes

short

SV Plus network ID

ipx_netw_id

short

IPX network ID

netw_name

char (8+1)

SV Plus network name assigned by user

active

short

flag for network active state

upgrade_status

short

Network upgrade status

0 = unknown

1 = upgrading

2 = not upgrading

reserved

int

reserved for future use


Table 3-5: NODE
Column Name Unique Identifier Field Data Type Description

node_id

yes

int

SV Plus node ID

netw_id

short

IPX network ID

node_name

char (10+1)

IPX node name

ipx_netw_id

short

IPX network ID. For IPX, IGX, BPX nodes only. AXIS, DAS, DNS nodes are assigned the network ID of their attached IPX/IGX/BPX node.

ipx_node_id

short

IPX node ID. For IPX, IGX, BPX nodes only; for AXIS, DAS, DNS nodes this field is set to 0.

netw_ip_address

int

network IP address for the node

lan_ip_address

int

LAN IP address for the node
Both netw_ip_address and lan_ip_address have same value.

alarm_state

short

node alarm state

0 = clear
Bit 1 = minor (1)
Bit 2 = major (2)
Bit 1 and 2 = unreachable (3)

Bit 8 = SV+ mode (64)

64 = clear & node is in SV+ mode
65 = minor & node is in SV+ mode
66 = major & node is in SV+ mode
67 = unreachable & node is in SV+ mode

gateway

short

flag for node acting as a gateway between two network domains

0 = not a gateway
1 = gateway
valid for structured networks only.

active

short

node active state flag

0 = inactive *
1 = active *
Inactive indicates that entry has been deleted.

platform

short

flag for platform type:
0 = IPX,
1 = BPX.
2 = IGX,
3 = AXIS,
4 = INS (DAS)
5 = DNS
6 = INSD

subtype

short

flag for a shelf

0 = Routing nodf
1 = Feeder or shelf

release

char (11+1)

SV+ software release revision
e.g. "8.4.0.A" indicates node is running 840A SW version

fs_inc_rate

short

FRP Foresight increase rate

fs_dec_rate

short

FRP Foresight decrease rate

fs_fdec_rate

short

FRP Foresight fast decrease rate

rst_timeout

short

Timeout for setting PVC rate to QIR

mode

short

Node mode (for AXIS node only)

0 = unknown

1 = init-sync

2 = syncing

3 = synced

mgmt_state

short

Node management state

reserved

int

reserved for future use


Table 3-6: PACKET LINE
Column Name Unique Identifier Field Data Type Description

pln_obj_id

yes

int

packet line object ID

l_network_id

short

local SV Plus network ID

l_node_id

yes

int

local SV Plus node ID

l_line

short

local logical trunk number

1_slot

short

local trunk slot number

l_port

short

local trunk logical port number

l_vtrk

short

local virtual trunk ID

card_type

short

packet line card type

3 = TXR

22 = NTC

34 = AIT

35 = FTC

103 = BNI_T3

104 = BNI_E3

110 = BNI_OC3

117 = BXM

interface

short

packet line interface type

0 = unknown
1 = T1
5 = E1

6 = subrate

7 = Broadband

line_load

int

Trunk load in cells/packets per second

For BPX/IGX truks units are cps

For IPX trunks units are pps

r_network_id

remote SV Plus network ID

r_node_id

int

remote SV Plus node ID

r_line

short

remote line number

r_slot

short

remote trunk logical slot number

r_port

short

remote trunk logical port number

r_vtrk

short

remote virtual trunk ID

alarm_state

short

packet line alarm state

0 = clear
1 = minor
2 = major

active

short

packet line active state

0 = inactive
1 = active
This field is unused.

status

short

packet line status field

1 = clear
2 = failed

stat_reserve

int

packet line statistical reserve field (in packets per second).

b_bq_depth

int

bursty data B queue depth

b_bq_efcn

int

bursty data B EFCN/ENCI threshold

clp_h_thresh

short

CLP high dropping threshold

clp_l_thresh

short

CLP low dropping threshold

time_load

int

time stamped load units

non_time

int

non-time stamped load units

v_load

int

voice load units

bursty_a_load

int

bursty data A load units

bursty_b_load

int

bursty data B load units

bursty_a_cmax

short

bursty data A Credit Max

bursty_b_cmax

short

bursty data B Credit Max

reserved

int

reserved for future use


Table 3-7: CIRCUIT LINE
Column Name Unique Identifier Field Data Type Description

cln_obj_id

yes

int

circuit line object ID

l_network_id

short

local SV Plus network ID

l_node_id

yes

int

local SV Plus node ID

l_line

short

local circuit line number

card_type

short

circuit line card type

3 = TXR ASI_T3 = 106
21 = CIP ASI_E3 = 107
29 = CDP

interface

short

circuit line interface type

0 = unknown
1 = T1
2 = E1
3 = T3/E3

active

short

circuit line active state

0 = inactive
1 = active

status

short

circuit line status field

1 = clear
2 = failed

reserved

int

reserved for future use


Table 3-8: FRP
Column Name Unique Identifier Field Data Type Description

frp_obj_id

yes

int

FRP port object ID

l_network_id

short

local SV Plus network ID

l_node_id

yes

int

local SV Plus node ID

shelf

int

shelf number. Set to 1 for AXIS ports, set to 0 for all other ports.

l_slot

short

local slot number

l -port

short

Physical port number

(logical port for UFM only)

port_speed

int

port speed in hundreds of bits per second (e.g. 256 kbps displays as 2560)

active

short

circuit line active state

0 = inactive
1 = active

status

short

FRP line status field

1 = clear

2 = failed

port_type

short

Type of port

1 = FR

4 = FRSM

5 = FUNI

6 = Frame Forward

7 = Port Concentrator

8 = Channelized UFM

queue_depth

int

port queue depth

ecn_thresh

in_

ECN queue depth

de_thresh

short

DE threshold

logical_port

short

Logical port number used in the MIB (For FRSM Port only). For FRP port it is 0.

line

short

Line number associated with this port. (For FRSM/UFM Port only)

Default value for IPX/IGX is 0

timeslot_num

short

Number of timeslots (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

timeslot_speed

short

Timeslot speed (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

1- speed = 56k

2- speed = 64k

port_bitmap

int

Port bitmap (For AXIS FRSM/UFM Port only)

Default value for IPX/IGX is 0

port_equ

short

Port Equeue service ratio (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

port_flag

short

Port flags between frames(For AXIS FRSM Port only)

Default value for IPX/IGX is 0

protocol_type

short

Signalling protocol type (For FRSM Port only )

1---other

2---noSignalling

3---strataLMI

4---annexAUNI

5---annexDUNI

6---annexANNI

7---annexDNNI

asyn_upd

short

Asynchronous Updates. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

link_timer

short

t391 Line Integrity Timer. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

poll_timer

short

t392 Polling Verification Timer. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

poll_counter

short

n391 Full Status Polling Counter. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

err_thresh

short

n392 Error Threshold. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

event_count

short

n393 Monitored Event Count. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

xmt_timer

short

Xmt CLLM Status Timer. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

rcv_timer

short

Rcv CLLM Status Timer. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

cllm_ena

short

CLLM enable/disable. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

signal_state

int

Port signalling state. (For AXIS FRSM Port only)

Default value for IPX/IGX is 0

1 = LMI failure
2 = CLLM failure

reserved

int

reserved for future use


Table 3-9: USER CONNECTION
Column Name Unique Identifier Field Data Type Description

l_node_id

yes

int

local SV Plus node ID

num_segs

short

Number of segments

termination

short

Type of local and remote end-points.

Bit(0) - Local end has feeder
Bit(1) - Remote end has feeder
Bit(2-4) - Local endpoint type
Voice_Data (0)
Frame-Relay (1)
ATM (2)
Bit(5-7) -Remote endpoint type
Voice_Data (0)
Frame-Relay (1)
ATM (2)

l_slot

yes

short

Local slot number

l_line

yes

short

Local line number (For FRSM connection only)

l_port

yes

short

Local port number
(logical port except for FRSM)

logical port = physical port (ASI/BXM/FRP)

logical port = physical line (AUSM4/CESM)

logical port (UFM/AUSM8)

Physical port (FRSM)

l_subchnl_1

yes

short

First local sub-channel number
For Frame relay end-points this is set to DLCI.

For ATM end-points this is set to VPI.

l_subchnl_2

yes

int

Second local sub-channel number
For Frame relay end-points this is set to 0.

For ATM end-points this is set to VCI.

lr_slot

short

Local slot number

lr_line

yes

short

Local line number (For AXIS connection only)

lr_port

short

Local port number

lr_subchnl_1

short

First local sub-channel number

lr_subchnl_2

int

Second local sub-channel number

lc_node_id

int

Local hub SV+ node id.

(Same as local node id for connections that originate in a routing node.)

lc_slot

short

Local hub slot number

(Same as local slot id for connections that originate in a routing node.)

lc_port

short

Local hub port number

(Same as local port id for connections that originate in a routing node.)

lc_subchnl_1

yes

short

First local hub sub-channel number

(Same as first local sub-channel number for connections that originate in a routing node.)

lc_subchnl_2

yes

int

Second local hub sub-channel number

(Same as second local sub-channel number for connections that originate in a routing node.)

rc_node_id

int

Remote hub SV+ node id.

(Same as remote node id for connections that originate in a routing node.)

rc_slot

short

Remote hub slot number

(Same as remote slot id for connections that originate in a routing node.)

rc_port

short

Remote hub port number

(Same as remote port id for connections that originate in a routing node.)

rc_subchnl_1

short

First remote hub sub-channel number

(Same as first remote sub-channel number for connections that originate in a routing node.)

rc_subchnl_2

int

Second remote hub sub-channel number

(Same as second remote sub-channel number for connections that originate in a routing node.)

rr_slot

short

Remote hub slot number

(Same as remote slot id for connections that originate in a routing node.)

rr_port

short

Remote hub port number

(Same as remote port id for connections that originate in a routing node.)

rr_subchnl_1

short

First remote hub sub-channel number

(Same as first remote sub-channel number for connections that originate in a routing node.)

rr_subchnl_2

int

Second remote hub sub-channel number

(Same as second remote sub-channel number for connections that originate in a routing node.)

r_node_id

int

Remote SV+ node id

r_slot

short

Remote slot number

r_line

short

Remote line number (For FRSM connection only)

r_port

short

Remote-end port number (logical port except for FRSM)

logical port = physical port (ASI/FRP)

logical port = physical line (AUSM4/CESM)

logical port (UFM/AUSM8)

Physical port (FRSM)

r_subchnl_1

short

First remote sub-channel number

r_subchnl_2

int

Second remote sub-channel number

parm_type

short

A flag to indicate if StrataCom or standard FR parameters are used.

state

short

Connection state

1 = Clear

2 = Fail

3 = Down

4 = Incomplete

proc_state

short

The processing state (used by data broker).

con_type

short

Connection type

0 = V_COMPR_CON

1 = V_ADPCM_CON

2 = V_CON

3 = V_PCM

4 = DATA

5 = Frame Relay

6 = ATM

7 = CE

sub_type

short

Service type

1 = ATF

2 = VBR

3 = CBR

4 = unknown

5 = ABR

6 = ATFST

7 = CE

8 = FR_VBR

9 = FR_ABR_FS

10= UBR

l_endpt_obj_id

int

Local endpoint object id.

lc_endpt_obj_id

int

Local hub endpoint object id.

rc_endpt_obj_id

int

Remote hub endpoint object id.

r_endpt_obj_id

int

Remote endpoint object id.

master_node_id

int

Master end node id.

master_lcon_obj_id

int

Master end logical connection object id.

l_rate_info

short

Local end combination field of rate info:

bit(7) Fast EIA Enabled(1)/Disabled(0)
bit(6) DFM Enabled(1)/Disabled(0)
bits(5-3) Encoding:
undefined(0)
7/8(1)
8/8(2)
8/8l(3)
7/8E(4)
bit(2-0) Load Type:
undefined(0)
voice(1)
non-TS(2)
TS(3)
Bursty Data A(4)
Bursty Data B(5)

l_mir

int

Local end minimum guaranteed bandwidth in hundreds of bits per second (e.g. 256 kbps displays as 2560)

l_qir

int

Local end QIR in hundreds of bits per second

l_pir

int

Local end PIR in hundreds of bits per second

l_vc_q_depth

int

Local end VC queue depth in bytes

l_vc_q_thresh

int

Local end VC queue threshold in bytes

l_vc_q_de_thresh

int

Local end VC queue DE threshold in bytes

l_eg_q_depth

int

Local end Egress queue depth in bytes

l_eg_q_de_thresh

int

Local end Egress queue DE threshold in bytes

l_eg_q_ecn_thresh

int

Local end Egress queue ECN threshold in bytes

l_de_tag_ena

int

Local end DE tagging enable/disable

l_cmax

short

Local end maximum threshold for FRP credit manager in packets

l_per_util

short

Local end percent utilization

l_con_info_flag

short

Local end connection information flags

bit(7) Foresight

Enabled (1)
Disabled (0)
bit(6)

High Priority (1)
bit(5-0) unused

l_cir

short

Local end CIR in bits per second

l_bc

int

Local end committed burst in bytes

l_be

int

Local end excess burst in bytes

l_eg_q_select

short

egress queue selection

l_ibs

int

Local end initial burst size (IBS) in bytes

l_channel_type

short

Local end channel type (currently used by

connections terminating on FRSM)

1= FR-NetworkInterWorking

2= FR-ServiceInterWorking-Transparent

3= FR-ServiceInterWorking-Translate

4= FR-FUNI
5 = Frame-Forwarding

l_fecn

short

Local end forward explicit congestion notification

l_de_to_clp_map

short

Local end discard-eligible to CLP mapping
2 = set DE 0 and set CLP 0

3 = set DE 1 and set CLP 1

l_clp_to_de_map

short

Local end CLP to discard-eligible mapping
2 = set DE 0 and set CLP 0

3 = set DE 1 and set CLP 1

l_efci_q_threshold

short

Local end EFCI queue threshold

l_cbs

int

Local end committed burst size

l_mfs

int

Local end maximum frame size

l_ccdv

int

Local end CCDV

l_clp_hi

short

Local end CLP high threshold

l_clp_lo

short

Local end CLP low threshold

l_fst_rate_up

short

Local end ForeSight rate up

l_fst_rate_dn

short

Local end ForeSight rate down

l_fst_fast_dn

short

Local end ForeSight fast down

l_fst_qir_to

short

Local end ForeSight QIR time out

l_fst_max_adj

int

Local end ForeSight maximum adjustment

l_clp_tagging

int

Local end CLP tagging

1 = disable

2 = enable

l_upc_enable

int

Local end UPC enable

1 = disable

2 = enable

l_rm_enable

int

Local end RM enable

1 = disable

2 = enable

l_u_fgcra

int

Local end FGCRA

1 = disable

2 = enable

l_u_scr_policing

int

Local end SCR policing

l_u_pcr01

int

Local end PCR 0 + 1 in 100 bps unit

l_u_ccdv01

int

Local end CCDV 0 + 1

l_u_ccdv0

int

Local end CCDV 0

l_max_buf_size

int

Local end maximum buffer size

l_cell_loss_period

int

Local end cell loss period

l_cdv_rx_t

int

Local end CDV received

l_nrm

short

Local End NRM

l_tbe

int

Local End TBE

l_frtt

short

Local End FRTT

l_vsvd

short

Local End VSVD

r_rate_info

short

Remote end combination field of rate info:

bit(7) Fast EIA

Enabled (1)
Disabled (0)
bit(6) DFM

Enabled (1)
Disabled (0)
bits(5-3) Encoding:
undefined (0)
7/8 (1)
8/8 (2)
8/8l (3)
7/8E (4)
bit(2-0) Load Type:
undefined (0)
voice (1)
non-TS (2)
TS (3)
Bursty Data A (4)
Bursty Data B (5)

r_mir

int

Remote end minimum guaranteed bandwidth in hundreds of bits per second (e.g. 256 kbps displays as 2560)

r_qir

int

Remote end QIR in 100 bps unit

r_pir

int

Remote end PIR in 100 bps unit

r_vc_q_depth

int

Remote end VC queue depth

r_vc_q_thresh

int

Remote end VC queue threshold

r_vc_de_thresh

int

Remote end VC queue DE threshold

r_eg_q_depth

int

Remote end Egress queue depth

r_eg_q_de_thresh

int

Remote end Egress queue DE threshold

r_eg_q_ecn_thresh

int

Remote end Egress queue ECN threshold

r_de_tag_ena

int

Remote end DE tagging enable/disable

r_cmax

short

Remote end maximum threshold for FRP credit manager

r_per_util

short

Remote end percent utilization

This parameter is taken from routing segment

r_con_info_flag

short

Remote end connection information flags

bit(7) Foresight Enabled(1)/Disabled(0)
bit(6) High Priority(1)
bit(5-0) unused

r_cir

int

Remote end CIRin 100 bps unit

r_bc

int

Remote end commited burst

default = 0

r_be

int

Remote end excess burst

default = 0

r_eg_q_select

short

egress queue selection

r_ibs

int

Remote end initial burst size

r_channel_type

short

Remote end channel type
default = 0

r_fecn

short

Remote end forward explicit congestion notification
default = 0

r_de_to_clp_map

short

Remote end discard-eligible to CLP mapping

2 = set DE 0 and set CLP 0

3 = set DE 1 and set CLP 1

r_clp_to_de_map

short

Remote end CLP to discard-eligible mapping

2 = set DE 0 and set CLP 0

3 = set DE 1 and set CLP 1

r_efci_q_threshold

short

Remote end EFCI queue threshold

r_cbs

int

Remote end committed burst size

r_mfs

int

Remote end maximum frame size

r_ccdv

int

Remote end CCDV

r_clp_hi

short

Remote end CLP high threshold

r_clp_lo

short

Remote end CLP low threshold

r_fst_rate_up

short

Remote end ForeSight rate up

r_fst_rate_dn

short

Remote end ForeSight rate down

r_fst_fast_dn

short

Remote end ForeSight fast down

r_fst_qir_to

short

Remote end ForeSight QIR time out

r_fst_max_adj

int

Remote end ForeSight maximum adjustment

r_clp_tagging

int

Remote end CLP tagging

r_upc_enable

int

Remote end UPC enable

r_rm_enable

int

Remote end RM enable

r_u_fgcra

int

Remote end FGCRA

r_u_scr_policing

int

Remote end SCR policing

r_u_pcr01

int

Remote end PCR 0 + 1 in 100 bps unit

r_u_ccdv01

int

Remote end CCDV 0 + 1

r_u_ccdv0

int

Remote end CCDV 0

r_max_buf_size

int

Remote end maximum buffer size

r_cell_loss_period

int

Remote end cell loss period

r_cdv_rx_t

int

Remote end CDV received

r_nrm

short

Remote End NRM

r_tbe

int

Remote End TBE

r_frtt

short

Remote End FRTT

r_vsvd

short

Remote End VSVD

cos

short

Class of Service

avoid_trk_type

short

Trunk types to avoid:
None (1)
Satellite (2)
Terrestrial (3)

avoid_zcs

short

Avoid ZCS trunks
True (1)

False (2)

snmp_index

int

The SNMP-Proxy index for user connection


Table 3-10: CONNECTION
Column Name Unique Identifier Field Data Type Description

con_obj_id

yes

int

Local-end Connection Object ID

rcon_obj_id

int

Remote-end Connection Object ID

lcon_obj_id

short

Local-end Logical Connection Object ID

master_flag

short

Flag that indicates if this end is the master.
True (1)
False (0)

l_network_id

short

local-end SV Plus network ID

l_node_id

yes

int

local-end SV Plus node ID

shelf

int

Shelf number

termination

short

local-end Type of local and remote end-points.

Bit(0)---Local end has feeder
Bit(1)---Remote end has feeder
Bit(2-4)---Local endpoint type
Voice_Data (0)
Frame-Relay (1)
ATM (2)
Bit(5-7) -Remote endpoint type.

Voice_Data (0)
Frame-Relay (1)
ATM (2)

l_slot

short

local-end slot number

l_line

short

local-end line number (For FRSM connection only)

l_channel

short

local-end logical port (physical port for FRSM)

l_dlci

short

local-end DLCI number

l_vci

int

local-end VCI number for AIT endpoint only (not valid for FRP/FRSM/UFM)

r_network_id

short

remote-end SV Plus network ID

r_node_id

int

remote-end SV Plus node ID

r_slot

short

remote-end slot number

r_channel

short

remote-end logical port (physical port for FRSM)

r_dlci

short

remote-end DLCI number

r_vci

int

remote-end VCI number for AIT endpoint only (not valid for FRP/FRSM/UFM)

con_type

short

connection type

0 = ADPCM voice
1 = ADPCM no voice activation detection (VAD)
2 = PCM voice
3 = transparent voice
4 = data (SDP)
5 = frame relay
6 = ATM

rate_info

short

combination field of rate information.

This field is a 16 bit value of which the lower order 8 bits are interpreted as 4 fields (bit 7, bit 6, bits 3-5, and bits 0-2). The values of the fields are the result of ORing together the following 16 bit values. *

0x08 = Fast EIA Enabled
0x40 = DFM enabled

0x08 = 7/8 Encoded
0x10 = 8/8 Encoded
0x18 = 8/8 Inverted Encoded
0x20 = 7/8 Inverted Encoded

0x01 = Voice
0x02 = Non-timed stamped
0x03 = Time-stamped
0x04 = Bursty data
0x05 = Multicast combination field of rate info:

bit(7) Fast EIA Enabled(1)/Disabled(0)
bit(6) DFM Enabled(1)/Disabled(0)
bits(5-3) Encoding:
undefined(0)
7/8(1)
8/8(2)
8/8l(3)
7/8E(4)
bit(2-0) Load Type:
undefined(0)
voice(1)
non-TS(2)
TS(3)
Bursty Data A(4)
Bursty Data B(5)

l_load_unit

short

local-end maximum number of packets per second allocated to the connection

r_load_unit

short

remote-end maximum number of packets per second allocated to the connection

min_bw

short

minimum guaranteed bandwidth in hundreds of bits per second

dax_con

short

DAX connection flag

0 = non DAX
1 = DAX

txr_card

short

flag to identify voice connection end point card is TXR card type

0 = non TXR
1 = TXR

active

short

connection active state

0 = inactive
1 = active

status

short

connection status
1 = clear
2 = failed
3 = down

qir

int

quiescent information rate in hundreds of bits per second

pir

int

peak information rate in hundreds of bits per second

vc_q_depth

int

vc queue depth in bytes

vc_q_thresh

int

vc queue threshol d in bytes (ingress queue ECN threshold)

vc_de_thresh

int

ingress queue DE threshold

eg_q_depth

int

egress queue depth in bytes

eg_q_de_thresh

int

egress queue DE threshold in bytes

eg_q_ecn_thresh

int

egress queue ECN threshold in bytes

de_tag_ena

int

DE tagging enable/disable

cmax

short

credit max.for a connection in packets

lper_util

short

local percent utilization

rper_util

short

remote percent utilization

conn_info_flag

short

connection information flag
bit(7) Foresight

Enabled (1)
Disabled (0)
bit(6)

SNA Priority

High (1)
Low (0)
bit(5-0) unused

cir

int

committed information rate in hundreds of bits per second

a_bit_status

short

connection a bit status field

Bit 7 is 1 if NNI a-bit status is OK

Bit 6 is 1 if NNI remote PVC does not exist

Bit 5 to Bit 0 unused

ibs

int

initial burst size

bc

int

burst-committed in bytes

default = 0

be

int

burst-excess in bytes

default = 0

eg_q_select

short

egress queue selection

efci_q_threshold

short

EFCI queue threshold

cbs

int

committed burst size

mfs

int

maximum frame size

ccdv

int

CCDV

clp_hi

short

CLP high threshold

clp_lo

short

CLP low threshold

fst_rate_up

short

ForeSight rate up

fst_rate_dn

short

ForeSight rate down

fst_fast_dn

short

ForeSight fast down

fst_qir_to

short

ForeSight QIR time out

fst_max_adj

int

ForeSight maximum adjustment

channel_type

short

channel type( currently used by

connections terminating on FRSM)

1= FR-NetworkInterWorking

2= FR-ServiceInterWorking-Transparent

3= FR-ServiceInterWorking-Translate

4= FR-FUNI

5= Frame-Forwarding

fecn

short

forward explicit congestion notification
default = 0

de_to_clp_map

short

discard-eligible to CLP mapping
2 = set DE 0 and set CLP 0

3 = set DE 1 and set CLP 1

clp_to_de_map

short

CLP to discard-eligible mapping
2 = set DE 0 and set CLP 0

3 = set DE 1 and set CLP 1

reserved

int

reserved for future use


Table 3-11: STAT_ENABLE
Column Name Unique Identifier Field Data Type Description

obj_id

yes

int

IPX/BPX object ID

l_node_id

yes

int

local SV Plus node ID

object_type

yes

short

object type
0 = connection
1 = circuit line (service line)
2 = packet line (trunk line)
3 = frame relay port

stat_type

yes

short

statistic type

bucket_type

yes

short

duration, in minutes, of the bucket

owner_netw_id

short

IPX network ID of node to which SV Plus is connected

owner_node_id

short

IPX Node ID to which SV Plus is connected

num_buckets

short

maximum number of buckets residing in the IPX real-time memory

bucket_size

short

size of bucket in bytes

retain_peak

short

flag to indicate to have peak saved. A two byte value where:

High order byte has the format:

bit 7 (high)

0 = interval in minutes
1 = interval in seconds
bits 0-6 = peak interval

Low order byte has the format:

0 = don't save peak
1 = save peak

auto_stat

short

flag to indicate whether the statistic is enabled by system by default

0 = not enabled by default
1 = enabled by default

enable_flag

short

flag to indicate the active status of the statistic type

0 = inactive
1 = active

collect_interval

int

the time interval in minutes to collect statistical data

enable_time

int

the UNIX time when the statistic was enabled

retain_period

int

the duration period in minutes of the records saved in the SV Plus database

reserved

int

reserved for future use


Table 3-12:
Column Name Unique Identifier Field Data Type Description

timestamp

yes

long

timestamp of the statistical record

pln_obj_id

yes

int

packet line object ID

l_node_id

yes

int

local SV Plus node ID

stat_type

yes

short

statistic type

bucket_type

yes

short

duration, in minutes, of each bucket

totald

float

total of raw data collected in the sample interval

peak

float

peak rate of raw data in the sample interval

PACKET_LN_DATA

Table 3-13:
Column Name Unique Identifier Field Data Type Description

timestamp

yes

int

timestamp of the statistical record

cln_obj_id

yes

int

circuit line object ID

l_node_id

yes

int

local SV Plus node ID

stat_type

yes

short

statistic type

bucket_type

yes

short

duration, in minutes, of each bucket

totald

float

total of raw data collected in the sample interval

peak

float

peak rate of raw data in the sample interval

CIRCUIT_LN_DATA

Table 3-14:
Column Name Unique Identifier Field Data Type Description

timestamp

yes

int

timestamp of the statistical record

frp_obj_id

yes

int

frame relay port object ID

l_node_id

yes

int

local SV Plus node ID

stat_type

yes

short

statistic type

bucket_type

yes

short

duration, in minutes, of each bucket

totald

float

total of raw data collected in the sample interval

peak

float

peak rate of raw data in the sample interval

FRP_DATA

Table 3-15: CONNECTION_DATA
Column Name Unique Identifier Field Data Type Description

timestamp

yes

int

timestamp of the statistical record

con_obj_id

yes

int

connection object ID

l_node_id

yes

int

local SV Plus node ID

stat_type

yes

short

statistic type

bucket_type

yes

short

duration, in minutes, of each bucket

totald

float

total of raw data collected in the sample interval

peak

float

peak rate of raw data in the sample interval


Table 3-16: IP_ADDRESS
Column Name Unique Identifier Field Data Type Description

network

yes

short

SV+ network ID

node_id

yes

int

SV+ node ID

slot

yes

short

slot number of FR card

port

yes

short

port number

IP address

char(16)

IP address of device on port

type

short

type of port

0 = UNI FRP
1 = NNI FRP
2 = ATM FRP

reserved

int

reserved for future use


Table 3-17:
Column Name Unique Identifier Field Data Type Description

lcon_obj_id

yes

int

logical connection object id

src_node_id

yes

int

SV+ source node id in the routes

lcon_type

yes

short

local lcon or junction lcon
lcon (0)

junction (1)

round_trip_delay

short

round trip delay (only applicable to local lcon)

dst_node_id

int

SV+destination node id in the local routes

l_lcon_index

short

local logical connection index

r_lcon_index

short

remote logical connection index

r_lcon_p_index

short

remote logical partner connection index

j_dst_node_id

int

SV+ destination node in the junction route

cos

short

Class of Service
False (0)

True (1)

group_flag

short

grouped connection
False (0)

True (1)

avoid_trk_type

short

Trunk types to avoid:
None (1)
Satellite (2)
Terrestrial (3)

avoid_zcs

short

Avoid ZCS trunks
False (0)

True (1)

pref_route

char

(255)

Preferred route

curr_route

char

(255)

Current route

LOGICAL_CONN

Table 3-18:
Column Name Unique Identifier Field Data Type Description

l_con_id

yes

int

the logical connection object id. It can be either a junction logical connection id or a non-junction connection id.

owner_node_id

yes

int

the SV+ node id that owns the route

hop_node_id

yes

int

the source SV+ node id

route_type

yes

short

current or preferred route
current (0)

preferred (1)
junction current (2)

junction preferred (3)

hop_number

short

the hop number

src_line_number

short

the source trunk line number

ROUTES

Table 3-19:
Column Name Unique
Identifier
Field
Data Type Description

con_obj_id

yes

int

ATM Connection segment object id

rcon_obj_id

int

Remote Connection Object ID

lcon_obj_id

int

Logical Connection Object ID

master_flag

short

Flag that indicates if this end is the master.
True (1)

False (0)

l_network_id

short

local SV Plus network ID

l_node_id

yes

int

local SV Plus node ID

termination

short

Type of local and remote end-points.

Bit(0)---Local end has feeder
Bit(1)---Remote end has feeder
Bit(2-4)---Local endpoint type
Voice_Data (0)
Frame-Relay (1)
ATM (2)
Bit(5-7)---Remote endpoint type.

Voice_Data (0)
Frame-Relay (1)
ATM (2)

l_slot

short

Local slot number

l_port

short

Local logical port number

l_vpi

short

Local vpi number

l_vci

int

Local vci number

r_network_id

short

Remote SV+ network id

r_node_id

int

Remote SV+ node id

r_slot

short

Remote slot number

r_port

short

Remote logical port number

r_vpi

short

Remote vpi number

r_vci

int

Remote vci number

con_type

short

Connection type (e.g. voice, data, frame relay, atm connection etc.)
ATM = 6

sub_type

short

Service type

1 = ATF

2 = VBR

3 = CBR

4 = unknown

5 = ABR

6 = ATFST

7 = CE

8 = FR_VBR

9 = FR_ABR_FS

10= UBR

mir

int

minimum information rate in 100 bits per second

qir

int

quiescent information rate in 100 bits per second

pir

int

peak information rate in 100 bits per second

cir

int

commited information rate in 100 bits per second

lper_util

short

Local Percent Utilization

rper_util

short

Remote Percent Utilization

active

short

Connection active state

0 = inactive

1 = active

status

short

Connection status field

1 = Clear

2 = Failed

3 = Down

con_info_flag

short

Connection information flag


bit(7) Foresight

Enabled (1)

Disabled (0)
bit(6)

SNA Priority
High (1)
Low (0)
bit(5-0) unused

ibs

int

initial burst size

vc_q_depth

int

vc queue depth in bytes

efci_q_threshold

short

EFCI queue threshold

cbs

int

committed burst size

mfs

int

maximum frame size

ccdv

int

CCDV

clp_hi

short

CLP high threshold

clp_lo

short

CLP low threshold

fst_rate_up

short

ForeSight rate up

fst_rate_dn

short

ForeSight rate down

fst_fast_dn

short

ForeSight fast down

fst_qir_to

short

ForeSight QIR time out

fst_max_adj

int

ForeSight maximum adjustment

clp_tagging

int

CLP tagging (enable = 2, disable = 1)

upc_enable

int

UPC enable (enable = 2, disable = 1)

rm_enable

int

RM enable (enable = 2, disable = 1)

u_fgcra

int

FGCRA (enable = 2, disable = 1)

u_scr_policing

int

SCR policing (CLP0 = 1, CLP0 and 1 = 2, off = 3)

u_pcr01

int

PCR 0 + 1

ccdv01

int

CCDV 0 + 1

ccdv0

int

CCDV 0

lcn

int

Logical Connection Number

nrm

short

NRM

tbe

int

TBE

frtt

short

FRTT

vsvd

short

VSVD

reserved

int

Reserved for future use

ATM CONNECTION

Table 3-20:
ColumnName Unique
Identifier
Field
Data Type Description

asiLine_obj_id

yes

int

ASI line BPX object id

l_network_id

short

Local SV+ network id

l_node_id

yes

int

Local SV+ node id

card_type

short

ASI line card type

(ASI_T3 = 106, ASI_E3 = 107

ASI_0C3_SMF = 110

ASI_OC3_MMF = 111

BXM = 117 )

interface

short

ASI line interface type
(3 = T3/E3)

l_slot

short

ASI line slot number

l_port

short

ASI line port number

active

short

ASI line active state

0 = inactive

1 = active

status

short

ASI line status field

1 = Clear

2 = Failed

reserved

int

Reserved for future use

ASI_LINE

Table 3-21:
ColumnName Unique
Identifier
Field
Data Type Description

asiPort_obj_id

yes

int

ASI port BPX object id

l_node_id

yes

int

Local SV+ node id

l_slot

short

ASI slot number

l_port

short

ASI physical port number

svc_in_use

short

SVC used (0 = unused, 1 = used)

svc_lcn_lo

int

SVC LCN Low value

svc_lcn_hi

int

SVC LCN High value

svc_vpi_lo

int

SVC VPI Low value

svc_vpi_hi

int

SVC VPI High value

svc_vci_lo

int

SVC VCI Low value

svc_vci_hi

int

SVC VCI High value

port_speed

int

Port speed (baud rate) in 100 bps

active

short

ASI port active state

0 = inactive

1 = active

status

short

ASI port status field

1 = Clear

2 = Failed.

reserved

int

Reserved for future use

ASI_PORT

Table 3-22:
ColumnName Unique
Identifier
Field
Data Type Description

fpdcon_obj_id

yes

int

FastPAD Connection FastPAD object id

lcon_obj_id

int

Logical Conn. Object Id

l_node_id

yes

int

Local SV+ node id

l_slot

short

Local slot number

l_port

short

Local port number

l_subtype

short

Local FastPAD connection subtype (e.g. voice, data, session, etc.)

l_fpdslot

short

Local FastPAD slot number

l_fpdport

short

Local FastPAD port number

l_fpddlci

int

Local FastPAD DLCI number

r_network_id

short

Remote SV+ network id

r_node_id

int

Remote SV+ node id

r_slot

short

Remote slot number

r_port

short

Remote port number

r_subtype

short

Remote FastPAD connection subtype (e.g. voice, data, session, etc.)

r_fpdslot

short

Remote FastPAD slot number

r_fpdport

short

Remote FastPAD port number

r_fpddlci

int

Remote FastPAD DLCI number

con_type

short

Connection type (e.g. voice, data, frame relay, atm, atf, FastPAD etc.)

0 = ADPCM voice
1 = ADPCM no voice activation detection (VAD)
2 = PCM voice
3 = transparent voice
4 = data (SDP)
5 = frame relay
6 = ATM

rate_info

short

Combination field of rate info:

bit(7) Fast EIA Enabled(1)/Disabled(0)
bit(6) DFM Enabled(1)/Disabled(0)
bits(5-3) Encoding:
undefined(0)
7/8(1)
8/8(2)
8/8l(3)
7/8E(4)
bit(2-0) Load Type:
undefined(0)
voice(1)
non-TS(2)
TS(3)
Bursty Data A(4)
Bursty Data B(5)

l_load_unit

short

Local max number of packets per second allocated

r_load_unit

short

Remote max number of packets per second allocated

mir

short

Minimum Information Rate in hundreds of bits per second

active

short

Connection active state

status

short

Connection status field

1 = Clear

2 = Failed

3 = Down

conn_info_flag

short

Connection information flags


bit(7) Foresight

Enabled (1)

Disabled (0)
bit(6)

High Priority (1)
bit(5-0) unused

reserved

int

Reserved for future use

FPD_CONNECTION

Table 3-23:
Column Name Unique
Identifier
Field
Data Type Description

ftcPort_obj_id

yes

int

FTC port IPX object id

l_network_id

short

Local SV+ network id

l_node_id

yes

int

Local SV+ node id

l_slot

short

FTC slot number

l_port

short

FTC port number

port_speed

int

Port speed (baud rate in 100 bps units)

active

short

FTC port active state

status

short

FTC port status field

1 = Clear

2 = Failed

reserved

int

Reserved for future use

FTC_PORT

Table 3-24:
Column Name Unique
Identifier
Field
Data Type Description

fpdNode_obj_id

yes

int

FastPAD node object id

network_id

short

SV+ network id

node_id

yes

int

SV+ node id

ipx_netw_id

short

IPX network id

ipx_node_id

int

IPX node id

l_slot

short

FastPAD slot number

l_port

short

FastPAD port number

fpd_name

char
[9 + 1]

FastPAD name

active

short

FastPAD active state

status

short

FastPAD status field

reserved

int

Reserved for future use

FPD_NODE

Table 3-25: FPD_CONN_DATA
ColumnName Unique
Identifier
Field
Data Type Description

timestamp

yes

int

Timestamp of the statistical data record

fpdcon_obj_id

yes

int

FastPAD connection IPX object id

l_node_id

yes

int

Local SV+ node id

stat_type

yes

short

Statistic type (object dependent field)

bucket_type

yes

short

Bucket type (duration in minutes of each collection bucket)

totald

float

Total raw data collected in the sample interval

peak

float

Peak raw data in the sample interval


Table 3-26: ASI_LN_DATA
ColumnName Unique
Identifier
Field
Data Type Description

timestamp

yes

int

Timestamp of the statistical data record

asiLine_obj_id

yes

int

ASI line BPX object id

l_node_id

yes

int

Local SV+ node id

stat_type

yes

short

Statistic type (object dependent field)

bucket_type

yes

short

Bucket type (duration in minutes of each collection bucket)

totald

float

Total raw data collected in the sample interval

peak

float

Peak raw data in the sample interval


Table 3-27:
ColumnName Unique
Identifier
Field
Data Type Description

timestamp

yes

int

Timestamp of the statistical data record

asiPort_obj_id

yes

int

ASI port BPX object id

l_node_id

yes

int

Local SV+ node id

stat_type

yes

short

Statistic type (object dependent field)

bucket_type

yes

short

Bucket type (duration in minutes of each collection bucket)

totald

float

Total raw data collected in the sample interval

peak

float

Peak raw data in the sample interval

ASI_PORT_DATA

Table 3-28:
ColumnName Unique
Identifier
Field
Data Type Description

timestamp

yes

int

Timestamp of the statistical data record

ftcPort_obj_id

yes

int

FTC port IPX object id

l_node_id

yes

int

Local SV+ node id

stat_type

yes

short

Statistic type (object dependent field)

bucket_type

yes

short

Bucket type (duration in minutes of each collection bucket)

totald

float

Total raw data collected in the sample interval

peak

float

Peak raw data in the sample interval

FTC_PORT_DATA

Table 3-29:
ColumnName Unique
Identifier
Field
Data Type Description

obj_id

int

Feeder (BIS) object id

name

char(11)

name of BIS

type

short

feeder type

subtype

short

Flag that indicates if this BIS is a feeder.
True (feeder only) (1)

False (routing only) (0)

ipaddress

yes

int

IP address of Feeder shelf

p_ipaddress

yes

int

IP address of Feeder's parent node

p_slot

short

Parent slot number

p_port

short

Parent port number

f_slot

short

Feeder slot number

f_port

short

Feeder port number

status

short

Alarm status of a BIS object

0 = clear

1 = minor

2 = major

3 = unreachable

active

short

BIS object active state

BIS_OBJECT

Table 3-30:
ColumnName Unique
Identifier
Field
Data Type Description

node_id

yes

int

SV+ node id of the AXIS

network_id

short

SV+ network id

name

char(10)

name of shelf

mac_addr

char(6)

MAC address

routing_ip_addr

int

IP address for routing

lan_ip_addr

int

IP address of Feeder shelf

slip_ip_addr

int

SLIP IP address

shelf

yes

int

shelf number

serial_id

char(21)

backplane serial number

shelf_type

short

Shelf type based on number of slots

1 = 16 slot shelf

(currently only used by AXIS)

status

short

ASM Alarm status of the shelf object

ASM alarm off (1)

ASM alarm on (2)

reserved

int

reserved for future use

SHELF

Table 3-31:
ColumnName Unique
Identifier
Field
Data Type Description

obj_id

int

SV+ object id of the AXIS

node_id

yes

int

SV+ node id of the AXIS

network_id

short

SV+ network id

node_type

short

SV+ node id

shelf

yes

int

shelf number

peri_type

yes

short

Alarm status of the Shelf:

other (1)

temperature (2)

Power Supply (3)

DC level (4)

Fan unit (5)

unit_num

yes

short

Unit numbers

status

int

Physical Alarm state

severity

short

Alarm severity

minor (1)

major (2)

alarm_num.

short

Alarm number

reserved

int

reserved for future use

PERIPHERAL

Table 3-32:
ColumnName Unique
Identifier
Field
Data Type Description

obj_id

int

SV+ object id of the AXIS

node_id

yes

int

SV+ node id of the AXIS

network_id

short

SV+ network id

node_type

short

SV+ node id

shelf

yes

int

shelf number

slot

yes

short

Slot number

fc_type

short

Front card type

asc (2),

bnm-T3 (10),

frsm-4T1 (30),

frsm-4E1 (31),

ausm-4T1 (40),

ausm-4E1 (41)

fc_dscrp

char(21)

Front card description (AXIS only)

fc_serial_num

char(7)

Front card serial number

fc_hw_rev

char(3)

Front card hardware revision

fc_fw_rev

char(21)

Front card firmware revision

fc_reset_reason

int

Front card Reset reason

Power Up (1),

Parity Error (2),

watchDog (3),

Resource Overflow (4),

Clear All Config (5),

Missing Task (6)

(AXIS only)

fc_state

int

Front card state

No Card (1),

Standby (2),

Active (3),

Failed (4),

Self Test (5),

Held in Reset (6),

mib_version

int

MIB version number (AXIS only)

bc_type

short

Back card type

lm-ASC (2),

lm-DB15-4T1 (16),

lm-DB15-4E1 (17),

lm-BNC-4E1 (18),

lm-T3-E3-D (32),

lm-T3-E3-B (33)

bc_dscrp

char(21)

Back card description(AXIS only)

bc_serial_num

char(7)

Back card serial number

bc_hw_rev

char(3)

Back card hardware revision

bc_fw_rev

char(9)

Back card firmware revision

bc_state

short

Back card state

Not Present (1)

Present (2)

rate_up

int

Rate up ( FRSM/AUSM only)

rate_dn

int

Rate down ( FRSM/AUSM only)

fast_dn

int

Rate fast down ( FRSM/AUSM only)

measure_time

int

RTD measure time ( FRSM/AUSM only)

qir_timeout

int

QIR timeout ( FRSM only)

chan_allowed

short

Channelized data allowed (FRSM only)

rate_ctrl_allowed

short

Rate control allowed (FRSM only)

curr_clk_src

short

Current clock source

pri_clk_src

short

Primary clock source

sec_clk_src

short

Secondary clock source

clk_impedence

short

Clock impedance

out_of_sync

short

Configuration upload failed during last resynchronization

reserved

int

reserved for future use

CARD

Table 3-33:
ColumnName Unique
Identifier
Field
Data Type Description

node_id

yes

int

SV+ node id of the AXIS

obj_id

yes

int

dsx1 or dsx3 line object id

network_id

small

SV+ network id

shelf

int

shelf number

slot

short

slot number

line

short

line number

line_type

short

line type

DS1_LINE (T1/E1) = 1

DS3_LINE (T3/E3) = 2

connector

short

dsx1 line connector type (dsx1 only)

DB-15 (1)

BNC (2)

enable

short

dsx1 line enable/disable(dsx1 only)

enable (1)

disable (2)

subtype

short

dsx1 or dsx3 line type

For dsx1-line:

dsx1ESF (1),

dsx1D4 (2),

dsx1E1 (3),

dsx1E1CRC (4),

dsx1E1MF (5),

dsx1E1CRC-MF (6),

dsx1E1clearchannel (7)

For dsx3-line:

dsx3 Cbit Parity (1),

g834-g804 (2)

coding

short

Line coding

dsx1JBZS (1),

dsx1B8ZS (2),

dsx1HDB3 (3),

dsx1AMI (4)

length

short

Line length

For T1 lines:

0 to 110 Feet (1),

110 to 220 Feet (2),

220 to 330 Feet (3),

330 to 440 Feet (4),

440 to 550 Feet (5),

550 to 660 Feet (6),

660 Feet Plus (7),

For E1 lines:

lineLength---75-Ohm (8),

lineLength---120-Ohm (9)

clock_src

short

Line Xmt clock source (dsx1 only)

LoopTiming (1),

LocalTiming (2)

loopback

short

Line loopback command

line_bitmap

int

Bit map of used DS0 for line (bit 0 corresponds to timeslot1, bit 31 corresponds to timeslot 32, FRSM only)

oof_criteria

short

Line Out of Frame Criteria (dsx3 only)

1=3 of 8 Framing bits in error

2 = 3 0f 16 Framing bits in error

aisc_check

small

Line AISc Bits Check (dsx3 only)

1 = Check `C' bits

2 = Ignore `C' bits

tx_timing_marker

small

Transmit Timing Marker

tx_payload_type

small

Transmit Payload Type

red_severity

short

Received LOS/OOF alarm severity

1 = Minor

2 = Major

rai_severity

short

RAI alarm severity

1 = Minor

2 = Major

stat_severity

short

Statistical alarm severity

1 = Minor

2 = Major

alarm_state

int

Line alarm state
It is represented by bitmap

0 = No Alarm

1 = Receiving RAI

2 = Transmitting RAI

4 = Receiving AIS

8 = Transmitting AIS

16= Receiving OOF

32= Receiving LOS

64= Near End Local Loopback in effect

128= Near End Remote Loopback in effect

256= Receiving test pattern

stat_alarm_state

int

Statistical Alarm state

(Currently unused in SV+)

agg_state

short

Aggregate Alarm state

0 = No alarm

15 = One of the parents in object hierarchy (such as card) is in alarm.

rate

short

Rate

hcs_masking

short

HCS masking

payload_scramble

short

Payload scramble

frame_scramble

short

Frame scramble

section_state

short

Section state

section_stat_sev

short

Section status severity

section_stat_state

short

Section status state

line_state

short

Line state

line_stat_sev

short

Line status severity

line_stat_state

short

Line status state

path_state

short

Path state

path_stat_sev

short

Path status severity

path_stat_state

short

Path status state

reserved

int

reserved for future use

LINE

Table 3-34:
ColumnName Unique
Identifier
Field
Data Type Description

node_id

yes

int

SV+ node id of the AXIS

obj_id

yes

int

PLCP object id

network_id

short

SV+ network id

shelf

int

shelf number

slot

short

Slot number

line

short

line number

plcp

short

PLCP number

enable

short

enable/disable (Not used in Release 8.1)

cell_frm

short

PLCP Cell framing (PLCP, ATM)

scramble

short

PLCP payload scramble enable/disable

1 = enableScrambling

2 = disableScrambling

loopback

short

PLCP loopback configuration

red_severity

short

Received LOS/OOF alarm severity

1 = Minor

2 = Major

rai_severity

short

RAI alarm severity

1 = Minor

2 = Major

lss_severity

short

LSS alarm severity

1 = Minor

2 = Major

stat_severity

short

Statistical alarm severity

1 = Minor

2 = Major

alarm_state

int

PLCP alarm state
Its represented by bitmap

0 = No Alarm

1 = Receiving RAI

2 = Transmitting RAI

4 = Receiving OOF State

8 = Receiving LSS Link UP

16 = Transmitting LSS Link UP

32 = Receiving LSS Link Down

64 = Transmitting LSS Link Down

128 = Local Loopback state

256 = Remote Line Loopback state

stat_alarm_state

int

Statistical Alarm state

(Unused in Release 8.1)

agg_state

short

Aggregate Alarm state:

0 = No alarm

15 = One of the parents in object hierarchy (such as card) is in alarm.

bit_err_corr

short

bit error correction

reserved

int

reserved for future use

PLCP

Table 3-35:
ColumnName Unique
Identifier
Field
Data Type Description

con_obj_id

yes

int

Connection object id (a.k.a. VC/End-Point Index)

master_flag

short

Flag that indicates if this end is the master

l_network_id

short

Local SV+ network id

l_node_id

yes

int

Local SV+ node id for IPX or AXIS

shelf

int

Shelf number

termination

short

Local and remote termination type

l_slot

short

Local slot number

l_port

short

Local port number (physical port number)

l_vpi

short

Local vpi number

l_vci

short

Local vci number

r_network_id

short

Remote SV+ network id

r_node_id

int

Remote SV+ node id

r_slot

short

Remote slot number

r_port

short

Remote port number (physical port number)

r_vpi

short

Remote vpi number

r_vci

short

Remote vci number

r_subtype

short

Remote FastPAD connection subtype (e.g. voice, data, session, etc.)

con_type

short

Connection type (e.g. voice, data, frame relay, atm, atf, FastPAD etc.)

0 = ADPCM voice
1 = ADPCM no voice activation detection (VAD)
2 = PCM voice
3 = transparent voice
4 = data (SDP)
5 = frame relay
6 = ATM

rate_info

short

Combination field of rate info:

bit(7) Fast EIA Enabled(1)/Disabled(0)
bit(6) DFM Enabled(1)/Disabled(0)
bits(5-3) Encoding:
undefined(0)
7/8(1)
8/8(2)
8/8l(3)
7/8E(4)
bit(2-0) Load Type:
undefined(0)
voice(1)
non-TS(2)
TS(3)
Bursty Data A(4)
Bursty Data B(5)

l_load_unit

int

Max size of the reassembly buffer (in octets)

cell_loss_period

int

Cell loss integration period in milliseconds

cdv_rx_t

int

Maximum cell arrival jitter tolerated by the reassembly process (in 10 microsecond increments)

comment

char
[20 + 1]

Comment field to be used to further qualify the CESM connection

active

short

Connection active state

(This field is unused)

status

short

Connection status field

1 = Clear

2 = Failed

3 = Down

CESM_CONNECTION

Table 3-36: AUSM_PORT
ColumnName Unique
Identifier
Field
Data Type Description

ausmp_obj_id

yes

int

SV+ object id of the AXIS

l_node_id

yes

int

SV+ Local node id

shelf

int

Shelf number

l_slot

short

Local slot number

line

short

Line number associated with this port

l_port

short

Physical port number for AUSM port

port_speed

int

Port speed (baud rate x 100 bps)

active

short

AUSM port active state

status

short

AUSM port alarm status field

1 = Clear

2 = Failed

signal_state

int

Port signalling state

port_type

short

Type of port

interface_type

short

Type of interface

protocol_type

short

Signalling protocol type (No signalling, ILMI)

poll_timer

short

T491 polling interval

err_thresh

short

N491 error threshold

signalling_vpi

int

Signalling VPI

signalling_vci

int

Signalling VCI

ilmi_trap_enable

short

ILMI Trap Enable state

trap_interval

short

Minimum interval between traps

keep_alive

short

Keep alive polling state

event_thresh

short

N492 event threshold

min_enquiry

short

T493 minimum enquiry interval

svc_in_use

short

SVC used

svc_lcn_lo

short

SVC LCN Low

svc_lcn_hi

short

SVC LCN High

svc_vpid_lo

short

SVC VPID Low

svc_vpid_hi

short

SVC VPID High

svc_vci_lo

int

SVC VCI Low

svc_vci_hi

int

SVC VCI High

svc_vpi_lo

short

SVC VPI Low

svc_vpi_hi

short

SVC VPI High

addr_Prefix

char
[20 + 1]

Network Prefix for the ATM address

ima_port

int

IMA Port number

line_map

int

Line mapping

num_red_links

short

Number of redundancy links

max_delay

short

Maximum delay

ima_master

short

IMA Master number

lcl_ima_id

short

Local IMA ID

rmt_ima_id

short

Remote IMA ID

line_order

char(16)

Line order list

obs_delay

short

OBS Delay

oversubscribed

short

Over subscribed indicator

logical_port

short

Logical port number for AUSM port

reserved

int

Reserved for future use


Table 3-37:
ColumnName Unique
Identifier
Field
Data Type Description

node_id

yes

int

SV+ node id of the AXIS

name

char
(10 +1)

name of DNS node

ip_addr

int

IP address of the DNS node

p_node_name

char
(10 +1)

name of primary DNS node

redun_name

char
(10 +1)

name of redundant DNS node

redun_ip_addr

int

IP address of the redundant DNS node

alarm_status

short

Alarm status of the DNS node object

Alarm off (1)

Alarm on (2)

oper_status

short

Current operating status of the DNS node object

Active (1)

Standby (2)

reserved

int

reserved for future use

DNS_NODE

Table 3-38: Redundant Card
Column Name Unique Identifier Field Data Type Description

network_id

short

SV+ network ID

node_id

yes

int

SV+ node ID

pri_slot

yes

short

Primary slot number

pri_type

short

Primary card type

pri_status

short

Primary card status

sec_slot

short

Secondary slot number

sec_type

short

Secondary card type

sec_status

short

Secondary card status

covered_slot

short

Covered slot number

red_type

short

Redundancy type

1-to-1 = 1 (y-cable)

1-to-n = 2


Table 3-39: Line Distribution
Column Name Unique Identifier Field Data Type Description

dist_idx

yes

short

Distribution index

network_id

short

SV+ network ID

node_id

yes

int

SV+ node ID

t3line

short

T3 line number

start_t1

short

Starting T1 line number

target_slot

short

Targeted slot number

target_line

short

Targeted line

num_lines

short

number of lines


Table 3-40: VP Range
Column Name Unique Identifier Field Data Type Description

network_id

short

SV+ network ID

node_id

yes

int

SV+ node ID

slot

yes

short

Slot number

rangenum

yes

short

Range number

port

short

Port number

min_vpi

int

Minimum VPI value

max_vpi

int

Maximum VPI value

Statistic Types

The value in the statistic type field depends upon the object type and the type of statistic as follows:

Connections (Object type = 0)

Voice (Sub-type = 0)

4 = packets received
5 = receive packets discarded
6 = packets transmitted
7 = projected packets transmitted
8 = supervisory packets transmitted
13 = seconds V.35 modem on
14 = seconds DSI enabled
15 = seconds off-hook
16 = seconds in service
19 = supervisory packets received

Data (Sub-type = 1)

6 = packets transmitted
7 = projected packets transmitted
8 = supervisory packets transmitted
16 = seconds in service
19 = supervisory packets received

Frame Relay (Sub-type = 2)

0 = frames received
1 = received frames discarded
2 = frames transmitted
3 = transmitted frames discarded
4 = packets received
6 = packets transmitted
9 = bytes received
10 = receive bytes discarded
11 = bytes transmitted
12 = transmit bytes discarded
16 = seconds in service
17 = frames transmitted with FECN
18 = frames transmitted with BECN
20 = minutes congested
21 = DE frames received
22 = DE frames transmitted
23 = DE frames dropped
24 = DE bytes received
25 = frames received in excess of CIR
26 = bytes received in excess of CIR
27 = frames transmitted in excess of CIR
28 = bytes transmitted in excess of CIR
29 = IWF Frames received and Aborted
30 = IWF Frames received with the EFCI bit set
31 = Rx frames discarded-deroute/down
32 = Rx bytes discarded-deroute/down
33 = Rx frames discarded VC Q overflow
34 = Rx bytes discarded VC Q overflow
35 = Tx frames discarded Q overflow
36 = Tx bytes discarded Q overflow
37 = Tx frames discarded ingress CRC
38 = Tx bytes discarded ingress CRC
39 = Tx frames discarded trunk discard
40 = Tx bytes discarded trunk discard
41 = Tx frames during egress LMI fail
42 = Tx bytes during egress LMI fail

FastPAD Voice (Sub-type = 3)

0 = Frames received
1 = Received frames discarded
2 = Frames transmitted
3 = Transmit frames discarded
4 = Packets received
5 = Receive packets discarded
6 = Packet transmitted
9 = Bytes received
10 = Received bytes discarded
11 = Bytes transmitted
12 = Transmitted bytes discarded
16 = Seconds in service
17 = Frames transmitted with FECN
18 = Frames transmitted with BECN
20 = Minutes congested
21 = DE frames received
22 = DE frames transmitted
23 = DE frames dropped
24 = DE bytes received
25 = Frames received in excess of CIR
26 = Bytes received in excess of CIR
27 = Frames transmitted in excess of CIR
28 = Bytes transmitted in excess of CIR
31 = Rx frames discarded- deroute/down
32 = Rx bytes discarded-deroute/down
33 = Rx frames discarded-VC-Q-overflow
34 = Rx bytes discarded-VC-Q-overflow
35 = Tx frame discarded-trunk discard
36 = Tx bytes discarded-Q-overflow
37 = Tx frames discarded-trunk discard
38 = Tx bytes discarded-ingress CRC
39 = Tx frames discarded-trunk discard
40 = Tx bytes discarded--trunk discard
41 = Tx frames during ingress LMI fail
42 =Tx bytes during ingress LMI fail

FastPAD Switched Voice (Sub-type = 4)

0 = Frames received
1 = Received frames discarded
2 = Frames transmitted
3 = Transmitted frames discarded
4 = Packets received
5 = Receive packets discarded
6 = Packets transmitted
9 = Bytes received
10 = Receive bytes discarded
11 = Bytes transmitted
12 = Transmitted bytes discarded
16 = seconds in service
17 = Frames transmitted with BECN
18 = Frames transmitted with FECN
20 = Minutes congested
21 = DE frames received
22 = DE frames transmitted
23 = DE frames dropped
24 = DE bytes received
25 = Frames received in excess of CIR
26 = Bytes received in excess of CIR
27 = Frames transmitted in excess of CIR
28 = Bytes transmitted in excess of CIR
31 = Rx frames discarded-deroute/down
32 = Rx bytes discarded-deroute/down
33 = Rx frames discarded-VC-Q-overflow
34 = Rx bytes discarded-VC-Q-overflow
35 = Tx frames discarded-Q-overflow
36 = Tx bytes discarded-Q-overflow
37 = Tx frames discarded-ingress CRC
38 = Tx bytes discarded-ingress CRC
39 = Tx frames discarded-trunk discard
40 = Tx bytes discarded-trunk discard
41 = Tx frames during ingress LMI fail
42 = Tx bytes during ingress LMI fail

FastPAD Data (Sub-type = 5)

0 = Frames received
1 = Received frames discarded
2 = Frames transmitted
3 = Transmitted frames discarded
4 = Packets received
5 = Receive packets discarded
6 = Packets transmitted
9 = Bytes received
10 = Receive bytes discarded
11 = Bytes transmitted
12 = Transmitted bytes discarded
16 = seconds in service
17 = Frames transmitted with FECN
18 = Frames transmitted with BECN
20 = Minutes congested
21 = DE frames received
22 = DE frames transmitted
23 = DE frames dropped
24 = DE bytes received
25 = Frames received in excess of CIR
26 = Bytes received in excess of CIR
27 = Frames transmitted in excess of CIR
28 = Bytes transmitted in excess of CIR
31 = Rx frames discarded-deroute/down
32 = Rx bytes discarded-deroute/down
33 = Rx frames discarded-VC-Q-overflow
34 = Rx bytes discarded-VC-Q-overflow
35 = Tx frames discarded-Q-overflow
36 = Tx bytes discarded-Q-overflow
37 = Tx frames discarded-ingress CRC
38 = Tx bytes discarded-ingress CRC
39 = Tx frames discarded-trunk discard
40 = Tx bytes discarded-trunk discard
42 = Tx bytes during ingress LMI fail

FastPAD Frame Relay (Sub-type = 6)

0 = Frames received
1 = Received frames discarded
2 = Frames transmitted
3 = Transmitted frames discarded
4 = Packets received
5 = Receive packets discarded
6 = Packets transmitted
9 = Bytes received
10 = Receive bytes discarded
11 = Bytes transmitted
12 = Transmitted bytes discarded
16 = Seconds in service
17 = Frames transmitted with FECN
18 = Frames transmitted with BECN
20 = Minutes congested
21 = DE frames received
22 = DE frames transmitted
23 = DE frames dropped
24 = DE bytes received
25 = Frames received in excess of CIR
26 = Bytes received in excess of CIR
27 = Frames transmitted in excess of CIR
28 = Bytes transmitted in excess of CIR
31 = Rx frames discarded-deroute/down
32 = Rx bytes discarded-deroute/down
33 = Rx frames discarded-VC-Q-overflow
34 = Rx bytes discarded-VC-Q-overflow
35 = Tx frames discarded-Q-overflow
36 = Tx bytes discarded-Q-overflow
37 = Tx frames discarded-ingress CRC
38 = Tx bytes discarded-ingress CRC
39 = Tx frames discarded-trunk discard
40 = Tx bytes discarded-trunk discard
41 = Tx frames during ingress LMI fail
42 =Tx bytes during ingress LMI fail

ASI Connection (Sub-type = 7)

1 = Received frames discarded
6 = Packets transmitted
12 = Transmitted bytes discarded
16 = Seconds in service
18 = Frames transmitted with BECN
21 = DE frames received
25 = Frames received in excess of CIR
28 = Bytes transmitted in excess of CIR
29 = Cells Rx port
30 = Frames Rx port
31 = Cells Tx network
32 = CLP Rx port
33 = Non-comp CLP Rx port
34 = Discard CLPth Rx port
35 = Discard Qfull Rx port
36 = EFCI Rx port
37 = AAL5 Rx port
38 = Non-comp Rx port
39 = Discarded failed Rx port
40 = AAL5 discarded Qfull Rx port
41 = Average Cell Q Depth
42 = Discarded Rsrc overflow Rx port
43 = Discarded Sbin full Rx port
44 = EFCI Tx port
45 = Cells Tx port
46 = Cells Rx network
47 = Discarded Qbin full
48 = Discarded Qbin CLPth port
49 = CLP Tx port
50 = BCM Rx port
51 = BCM Tx network
52 = OAM Tx network
53 = AIS Rx port
54 = FERF Rx port
55 = Cells Rx discarded due to rsrc overflow
56 = Cells Rx discarded due to VC threshold violation
57 = Current egress VC Queue Depth
58 = Number of good PDUs Rx by SAR
59 = Number of good PDUs Tx by SAR
60 = Rx PDUs discarded on ingress by SAR
61 = Tx PDUs discarded on egress by SAR
62 = Invalid crc32 PDU Rx by SAR
63 = Forward abort PDU Rx by SAR
64 = Invalid-length PDU Rx by SAR
65 = Invalid CPI snap PDUs Rx by SAR
66 = Invalid Lc snap PDUs Rx by SAR
67 = Frames Rx by SAR
68 = Short-length failures detected by SAR
69 = Long-length failures detected by SAR

AXIS Frame Relay (Sub-type = 8)

0 = Frames received
1 = Received frames discarded
2 = Frames transmitted
3 = Transmitted frames discarded
9 = Bytes received
10 = Receive bytes discarded
11 = Bytes transmitted
12 = Transmitted bytes discarded
16 = Seconds in service
17 = Frames transmitted with FECN
18 = Frames transmitted with BECN
21 = DE frames received
22 = DE frames transmitted
23 = DE frames dropped
24 = DE bytes received
33 = Rx frames discarded-VC-Q-overflow
34 = Rx bytes discarded-VC-Q-overflow
35 = Tx frames discarded-Q-overflow
36 = Tx bytes discarded-Q-overflow
37 = Tx frames discarded-ingress CRC
39 = Tx frames discarded-trunk discard
41 = Tx frames during ingress LMI fail
42 =Tx bytes during ingress LMI fail
43 = Rx Frames Discarded UPC
44 = Tx Bytes Tagged DE
45 = Tx Frames Tagged DE
46 = Tx Frames Invalid CPIs
47 = Tx Frames Length Violations
48 = Tx Frames Oversize SDUs
49 = Tx Frames Unknown Protocols
50 = Rx Frames Unknown Protocols

AXIS ATM Connection (Sub-type = 9)

16 = Seconds In Service
20 = Minutes Congested
34 = Discard CLPth Rx Port
35 = Discard Qfull Rx Port
55 = Number of Cells Rx w/CLP Set
56 = Number Of Cells Rx w/EFCI Set
57 = Number of Cells Rx w/UPC CLP Set
58 = AAL1 Sequence Mismatch
59 = Discarded Cells for Shelf Alarm
61 = Total Cells Tx from Line
70 = VC queue flushed by SAR

CE Connection (Sub-type = 10)

58 = AAL1 Sequence Mismatch
60 = Rx Buffer Overflows
62 = Rx Buffer Underflows
63 = Rx Buffer Overflows
64 = HCS Correctable Error
65 = Loss of Pointer
66 = Loss of Cell Delineation
69 = Tx Bytes Discarded-Q-Overflow
70 = Tx Cells Inserted-Q-Underflow
71 = Total Cells Tx to Line
72 = Total Cells Rx to Line

Data Connection (Object type = 1)

T1 (Sub-type = 0)

0 = bipolar violations
1 = frame slips
2 = out of frames
3 = losses of signal
4 = frame bit errors
5 = CRC errors

E1/J1 (Sub-type = 1)

0 = bipolar violations
1 = frame slips
2 = out of frames
3 = losses of signal
4 = frame bit errors
5 = CRC errors
6 = out of multi-frames
16 = all ones in timeslot 0

ASI (Sub-type = 2)

28 = B3ZS Line Code Violations
29 = Line Errored Seconds
30 = Line Severely Errored Seconds
31 = P-bit Line Parity Errors
32 = Errored Seconds - Parity
33 = Severely Errored Seconds - Parity
39 = Unavailable seconds
40 = PLCP BIP-8 Errors
41 = BIP-8 Errored Seconds
42 = BIP-8 Severely Errored Seconds
43 = PLCP Severely Errored Framing Seconds
44 = PLCP Unavailable Seconds
45 = HCS Errors
142 = PLCP FEBE Err Secs
143 = PLCP FEBE Severely Err Secs
144 = PLCP FE Counts
145 = PLCP FEBE Counts
146 = HCS Errored Seconds
147 = HCS Severely Errored Seconds
150 = YEL Transitions
152 = Alarm Indication Signal
169 = Loss of Cell Delineation
170 = Loss of Pointer
171 = OC3 Path AIS
172 = OC3 Path YEL
173 = Section BIP-8
174 = Line BIP-24
175 = Line FEBE
176 = Path BIP-8
177 = Path FEBE
178 = Section BIP-8 Errored Seconds
179 = Line BIP-24 Errored Seconds
180 = Line FEBE Errored Seconds
181 = Path BIP-8 Errored Seconds
182 = Path FEBE Errored Seconds
184 = Section Severely Errored Framing Seconds
185 = Line BIP-24 Severely Errored Seconds
186 = Line FEBE Severely Errored Seconds
187 = Path BIP-8 Severely Errored Seconds
188 = Path FEBE Severely Errored Seconds
189 = Line Unavailable Seconds
190 = Line Far End Unavailable Seconds
191 = Path Unavailable Seconds
192 = Path Far End Unavailable Seconds
193 = HCS Correctable Error
194 = HCS Correctable Error Errored Seconds
195 = HCS Correctable Error Severely Errored Seconds

AXIS E1/T1 (Sub-type = 3)

 2 = out of frames
 3 = losses of signal
 4 = frame bit errors

Trunk Lines (Object type = 2)

Narrowband (Sub-type = 0)

0 = bipolar violations
1 = frame slips
2 = out of frames
3 = losses of signal
4 = frame bit errors
5 = CRC errors
8 = packet out of frames
9 = packet CRC errors
10 = bad clock errors
11 = voice packets dropped
12 = TS packets dropped
13 = non-TS packets dropped
14 = High Priority packets dropped
15 = BData A packets dropped
16 = BData B packets dropped
17 = voice packets transmitted
18 = TS packets transmitted
19 = non-TS packets transmitted
20 = High Priority packets transmitted
21 = BData A packets transmitted
22 = BData B packets transmitted
23 = total packets transmitted
24 = BData A CLP packets dropped
25 = BData B CLP packets dropped
26 = BData A EFCN packets transmitted
27 = BData B EFCN packets transmitted
148 = BData A CLP packets transmitted
149 = BData B CLP packets transmitted

IPX_ATM (Sub-type = 1)

2 = out of frames
3 = losses of signal
9 = packet CRC errors
11 = voice packets dropped
12 = TS packets dropped
13 = non-TS packets dropped
14 = high priority packets dropped
15 = BData A packets dropped
16 = BData B packets dropped
17 = voice packets transmitted
18 = TS packets transmitted
19 = non-TS packets transmitted
20 = high priority packets transmitted
21 = BData A packets transmitted
22 = BData B packets transmitted
23 = total packets transmitted
24 = BData A CLP packets dropped
25 = BData B CLP packets dropped
26 = BData A EFCN packets transmitted
27 = BData B EFCN packets transmitted
28 = line code violations
29 = line errored seconds
30 = line severely errored seconds
31 = P-bit parity code violations
32 = errored seconds - line
33 = severely errored seconds - line
34 = C-bit parity code violations
35 = errored seconds - path
36 = severely errored seconds - path
37 = severely errored framing seconds
38 = alarm indication signal seconds
39 = unavailable seconds
45 = ATM cell header HEC errors
47 = Tx voice cells dropped
48 = Tx TS cells dropped
49 = Tx non-TS cells dropped
50 = Tx high priority cells dropped
51 = Tx Bdata A cells dropped
52 = Tx Bdata B cells dropped
53 = voice cells Tx to line
54 = TS cells Tx to line
55 = non TS cells Tx to line
56 = high priority cells Tx to line
57 = Bdata A cells Tx to line
58 = Bdata B cells Tx to line
59 = half full cells Tx to line
60 = full cells Tx to line
61 = total cells Tx to line
62 = Tx Bdata A CLP cells dropped
63 = Tx Bdata B CLP cells dropped
64 = Bdata A EFCN cells Tx to line
65 = Bdata B EFCN cells Tx to line
66 = half full cells Rx from line
67 = full cells Rx from line
68 = total cells Rx from line
69 = total packets Rx from line
70 = Rx voice packets dropped
71 = Rx TS packets dropped
72 = Rx non-TS packets dropped
73 = Rx high priority packets dropped
74 = Rx Bdata A packets dropped
75 = Rx Bdata B packets dropped
82 = Rx Bdata A CLP packets dropped
83 = Rx Bdata B CLP packets dropped
87 = Rx voice cells dropped
88 = Rx TS cells dropped
89 = Rx non-TS cells dropped
90 = Rx high priority cells dropped
91 = Rx Bdata A cells dropped
92 = Rx Bdata B cells dropped
93 = Rx Bdata A CLP cells dropped
94 = Rx Bdata B CLP cells dropped
140 = FEBE counts
141 = FERR counts (M-bit or F-bit)
142 = PLCP FEBE errored seconds
143 = PLCP FEBE severely errored seconds
144 = PLCP FEBE counts
145 = PLCP FE counts
146 = ATM HEC errored seconds
147 = ATM HEC severely errored seconds
148 = BData A CLP Packets Transmitted
149 = BData B CLP Packets Transmitted
160 = CGW Packets Received from the IPX Network
161 = CGW Cells Transmitted to Line
162 = CGW Frames Relayed to Line
163 = CGW Aborted Frames Transmitted to Line
166 = CGW Packets Transmitted to the IPX Network
167 = CGW Cells Received from Line
171 = CGW Bad CRC-32 Frames Rx From Line
173 = CGW Bad CRC-16 Frames Rx From IPX
177 = OAM Loopback Cells Transmitted
178 = OAM AIS Cells Transmitted
179 = OAM FERF Cells Transmitted
180 = OAM RTD Cells Transmitted
181 = OAM RA Cells Transmitted
183 = OAM CC Cells Transmitted
185 = OAM Loopback Cells Received
186 = OAM AIS Cells Received
187 = OAM FERF Cells Received
188 = OAM RTD Cells Received
189 = OAM RA Cells Received
191 = OAM CC Cells Received

BPX_ATM (Sub-type = 2)

2 = out of frames
3 = losses of signal
28 = B3ZS line code violations
29 = line errored seconds
30 = line severely errored seconds
31 = P-bit parity code violations
32 = errored seconds - line
33 = severely errored seconds - line
34 = C-bit parity code violations
35 = errored seconds - path
36 = severely errored seconds - path
37 = severely errored framing seconds
38 = alarm indication signal seconds
39 = unavailable seconds
45 = ATM cell header HEC errors
47 = Tx voice cells dropped
48 = Tx TS cells dropped
49 = Tx non-TS cells dropped
50 = Tx high priority cells dropped
51 = Tx Bdata A cells dropped
52 = Tx Bdata B cells dropped
53 = voice cells Tx to line
54 = TS cells Tx to line
55 = non TS cells Tx to line
56 = high priority cells Tx to line
57 = Bdata A cells Tx to line
58 = Bdata B cells Tx to line
61 = total cells Tx to line
62 = Tx Bdata A CLP cells dropped
63 = Tx Bdata B CLP cells dropped
64 = Bdata A EFCN cells Tx to line
65 = Bdata B EFCN cells Tx to line
68 = total cells Rx from line
87 = Rx voice cells dropped
88 = Rx TS cells dropped
89 = Rx non-TS cells dropped
90 = Rx high priority cells dropped
91 = Rx Bdata A cells dropped
92 = Rx Bdata B cells dropped
93 = Rx Bdata A CLP cells dropped
94 = Rx Bdata B CLP cells dropped
140 = FEBE counts
141 = FERR counts (M-bit or F-bit)
142 = PLCP FEBE errored seconds
143 = PLCP FEBE severely errored seconds
144 = PLCP FEBE counts
145 = PLCP FE errored seconds
146 = ATM HEC errored counts
147 = ATM HEC severely errored counts
150 = DS3 yellow transition counts
151 = PLCP yellow transition counts
152 = AIS transition counts
155 = Tx voice CLP cells dropped
156 = Tx TS CLP cells dropped
157 = Tx non-TS CLP cells dropped
158 = Tx high priority CLP cells dropped
160 = Tx CBR Cells Served
161 = Tx VBR Cells Served
162 = Tx ABR Cells Served
163 =Tx CBR CLP cells dropped
164 =Tx VBR CLP cells dropped
165 =Tx ABR CLP cells dropped
167 =Tx VBR Overflow cells dropped
168 =Tx ABR Overflow cells dropped
169 = Loss of Cell Delineation
170 = Loss of Pointer
171 = OC3 Path AIS
172 = OC3 Path YEL
173 = Section BIP-8
174 = Line BIP-24
175 = Line FEBE
176 = Path BIP-8
177 = Path FEBE
178 = Section BIP-8 Errored Seconds
179 = Line BIP-24 Errored Seconds
180 = Line FEBE Errored Seconds
181 = Path BIP-8 Errored Seconds
182 = Path FEBE Errored Seconds
184 = Section Severely Errored Framing Seconds
185 = Line BIP-24 Severely Errored Seconds
186 = Line FEBE Severely Errored Seconds
187 = Path BIP-8 Severely Errored Seconds
188 = Path FEBE Severely Errored Seconds
189 = Line Unavailable Seconds
190 = Line Far End Unavailable Seconds
191 = Path Unavailable Seconds
192 = Path Far End Unavailable Seconds
193 = HCS Correctable Error
194 = HCS Correctable Error Errored Seconds
195 = HCS Correctable Error Severely Errored Seconds

AXIS Narrowband (Sub-type = 3)

2 = out of frames
3 = losses of signal
4 = frame bit errors

AXIS ATM (Sub-type = 4)

2 = out of frames
3 = losses of signal
51 = Tx BData A Cells Dropped
61 = Total Cells Tx to Line
142 = PLCP FEBE errored seconds
143 = PLCP FEBE severely errored seconds
144 = PLCP FEBE counts
145 = PLCP FE counts
150 = DS3 yellow transition counts

Ports (Object type = 3)

Frame Relay Port (Sub-type = 0)

0 = frames received
1 = frames transmitted
2 = bytes received
3 = bytes transmitted
4 = frames transmitted with FECN
5 = frames transmitted with BECN
6 = receive frame CRC errors
7 = invalid format receive frames
8 = receive frame alignment errors
9 = illegal length receive frames
10 = number of DMA overruns
11 = LMI status enquiries
12 = LMI status transmit count
13 = LMI status update count
14 = LMI invalid status enquiries
15 = LMI link timeout errors
16 = LMI keepalive sequence errors
17 = receive frames undefined DLCI errors
18 = DE frames dropped
19 = transmit status enquiries
20 = received status counter
21 = asynchronous status counter
22 = invalid sequence number count
23 = transmit protocol timeout count
24 = CLLM messages frames transmitted
25 = CLLM messages bytes transmitted
26 = CLLM messages frames received
27 = CLLM messages bytes received
28 = CLLM failures
29 = Tx frames discarded queue overflow
30 = Tx bytes discarded queue overflow
31 = Tx frames while ingress LMI fail
32 = Tx bytes while ingress LMI fail

ASI Port (Sub-type = 1)

0 = Unknown VPI/VCI
1 = Cell buffer overflow
2 = Non-zero GFC count
5 = AIS Cells received
6 = Ex FERF Cell
7 = Number of cells Rx
8 = Number of cells Rx w/CLP set
9 = Number of cells Rx w/EFCI set
10 = Number of BCM cells Rx
11 = Number of cells Tx
12 = OAM cells Rx count
13 = Tx Payload Err Due to BIP-16 Err
14 = Number of cells Tx w/CLP set
15 = Number of cells Tx w/EFCI set
16 = Tx Header Error Discard
17 = Get Request Rx
18 = GetNextReq Rx
19 = GetNextReq Tx
20 = SetRequest Rx
21 =Traps Rx
22 = GetResp Rx
23 = GetRequest Tx
24 = GetResp Tx
25 = Trap Tx
26 = Unknown Rx
27 = Status Tx
28 = UpdtStatus Tx
29 = Status Ack Tx
30 = Status Enq Rx
31 = Status Enq Tx
32 = Status Rx
33 = UpdtStatus Rx
34 = Status Ack Rx
35 = Invalid LMI Rx
36 = Invalid LMI Length Rx
37 = Unknown LMI Rx
38 = Invalid LMI IE Rx
39 = Invalid Transaction IDs
64 = Cells Rx w/CLP 0
65 = Cells Rx w/CLP 0 discarded
66 = Cells Rx w/CLP discarded
67 = Cells Tx w/CLP 0
68 = Egress OAM Cell Count
69 = Ingress RM Cell Count
70 = Egress RM Cell Count

FastPAD Port (Sub-type = 2)

0 = Frames received
1 = Frames transmitted
2 = Bytes received
3 = Bytes transmitted
4 = Frames transmitted with.FECN
5 = Frames transmitted with.BECN
6 = Receive frame CRC errors
7 = Invalid format receive frames
8 = Receive frame alignment errors
9 = Illegal length receive frames
10 = Number of DMA overruns
11 = LMI status enquiries
12 = LMI status transmit count
13 = LMI status update count
14 = LMI invalid status enquiries
15 = LMI link timeout errors
16 = LMI keepalive sequence errors
17 = Receive frame undefined DLCI errors
18 = DE frames dropped
19 = Transmit status enquiries
20 = Receive status counter
21 = Asynchronous status counter
22 = Invalid sequence number count
23 = Transmit protocol timeout count
24 = CLLM message frames transmitted
25 = CLLM message bytes transmitted
26 = CLLM message frames received
27 = CLLM message bytes received
28 = CLLM failures
29 = Tx frames discarded-queue overflow
30 = Tx bytes discarded-queue overflow
31 = Tx frames while ingress LMI fail
32 =Tx bytes while ingress LMI fail

AXIS Frame Relay Port (Sub-type = 3)

0 = Frames received
1 = Frames transmitted
2 = Bytes received
3 = Bytes transmitted
4 = Frames transmitted with.FECN
5 = Frames transmitted with.BECN
6 = Receive frame CRC errors
7 = Invalid format receive frames
8 = Receive frame alignment errors
9 = Illegal length receive frames
11 = LMI status enquiries
12 = LMI Status Transmit Count
13 = LMI status update count
14 = LMI invalid status enquiries
15 = LMI link timeout errors
17 = Receive frame undefined DLCI errors
18 = DE frames dropped
19 = Transmit status enquiries
20 = Received Status Counter
21 = Asynchronous Status Counter
22 = Invalid sequence number count
23 = Transmit Protocol Timeout Count
29 = Tx frames discarded-queue overflow
30 = Tx bytes discarded-queue overflow
31 = Tx frames while ingress LMI fail
32 =Tx bytes while ingress LMI fail
33 = Receive NNI Sequence Mismatch

AXIS ATM Port (Sub-type = 4)

0 = Unknown VPI/VCI
2 = Non-zero GFC count
5 = Rx FERF Cells
6 = SNMP PDU Received
14 = Number of Cells Tx w/CLP Set
15 = Number of Cells Tx w/EFCI Set
17 = GetRequest Rx
18 = GetNext Request Rx
20 = SetRequest Rx
21 = Trap Rx
22 = GetResponse Rx
23 = GetRequest Tx
24 = GetResponse Tx
25 = Trap Tx
40 = Total Cells Rx from Line
41 = Total Cells Tx to Line
42 = OAM Loopback Cells Rx
43 = OAM Loopback Cells Tx
44 = OAM CRC Err Cells Rx
45 = Tx AIS Cells
46 = Discard Cells Tx for Port Alarm
47 = SNMP PDU Received
48 = Invalid PDU Received
49 = ASN1 Parse Error
50 = No Such Name Error
51 =Too Big Error
52 = ACP Cells Received
53 = ACP Cells Received with CRC-10 Error
54 = ACP Cells Transmitted
55 = ACP Cell Transmission Failures
56 = HEC Errored cells received per IMA group


hometocprevnextglossaryfeedbacksearchhelp