The 8.4.10 Cisco StrataView Plus for AIX software release supports the existing Cisco StrataCom switch family (including the Cisco StrataCom IGX and Cisco StrataCom BPX) running either Switch software version 8.2.5x or 8.4 based releases, and introduces the following features:
The Connection Service Agent is enhanced to support management of ATM-ATM and ATM-FR types of connections for both SWSW 8.4 based and SWSW 8.2.5x based releases.
The Port Service Agent is enhanced to support ASI ports and BXM (Monarch) OC3 and OC12 ports for both SWSW 8.4 based and SWSW 8.2.5x based releases.
The Connection Service Agent and Port Service Agent are enhanced to support AXIS release 4.0.02 cards including CESM4, FRSM4, AUSM4, BNM T3/E3, BNM 155, SRM T1/E1, SRM 3T3, IMATM, FRSM8, FRSM-HS1/X21 and AUSM8.
The Port Service Agent is enhanced to support ELMI feature for AXIS release 4.0.02 FRSM4, FRSM8 and FRSM-HS1/X21 cards.
The Connection Service Agent is enhanced to support SWSW 8.2.5x release Service Interworking feature and UFM-U cards for IGX.
The Equipment Management application is enhanced to support management of SRM 1:1, 1:N redundancy and IMATM cards for AXIS release 3.
The statd process is replaced by emsd/emsc (parent/child processes) to enhance the sync up performance for both SWSW 8.4 based and SWSW 8.2.5x based releases.
The Equipment Management application is enhanced to support AXIS release 4.0.02 cards including CESM4, FRSM4, AUSM4, BNM T3/E3, BNM 155, SRM T1/E1, SRM 3T3, IMATM, FRSM8, FRSM-HS1/X21 and AUSM8.
The Equipment Management application is enhanced to support ELMI feature for AXIS release 4.0.02 FRSM4, FRSM8 and FRSM-HS1/X21 cards.
The Equipment Management application is enhanced to support real time counter feature for AXIS release 4 AUSM4, AUSM8 and IMATM cards.
Network Browser is a new application that summarizes and displays the status of all nodes in a tabular form for both SWSW 8.4 based and SWSW 8.2.5x based releases.
SV+ Administration application is added to SV+ desktop. The user is able to view system error log and SV+ process status.
NwTopology and HPOvTopology map are enhanced to discover and display Cisco 3800 nodes and ESP (Extended Services Processor) nodes for SWSW 8.2.5x based release.
SV+ 8.4.10 will support networks with 200,000 end-to-end user connections, and will synchronize with these networks within 2 hours on a recommended high end machine configuration for both SWSW 8.4 based and SWSW 8.2.5x based releases.
SV+ 8.4.10 Connection Manager is enhanced to support new ATM connection types, such as UBR and standard ABR connections for both SWSW 8.4 based and SWSW 8.2.5x based releases.
SV+ 8.4.10 Connection Manager is enhanced to support SWSW 8.2.5x release SIW feature and UFM-U cards for IGX.
The Fault management and Statistics Collection Manager are enhanced to support BXM and AXIS release 4.0.02 cards including CESM4, FRSM4, AUSM4, BNM T3/E3, BNM 155, SRM T1/E1, SRM 3T3, IMATM, FRSM8, FRSM-HS1/X21 and AUSM8.
The Fault management is enhanced to support traps sent by the Cisco 3800 and ESP (Extended Services Processor) nodes for SWSW 8.2.5x based release.
SV+ 8.4.10 supports image download feature for routing nodes via TFTP protocol for both SWSW 8.4 based and SWSW 8.2.5x based releases.
SV+ 8.4.10 supports the image download feature for ESP nodes via TFTP protocol for SWSW 8.2.5x based release.
SV+ 8.4.10 is extended to support the configuration save and restore feature for ESP nodes for SWSW 8.2.5x based release.
SV+ 8.4.10 supports 40 simultaneous SV+ desktops with proper hardware configuration for both SWSW 8.4 based and SWSW 8.2.5x based releases.
SV+ 8.4.10 supports physical port scheme for FRSM and logical port scheme for all other cards. The physical port support is implemented on EM, CM and service proxies. For CESM and FRP, logical port scheme and physical port scheme are the same.
SV+ 8.4.10 SCM is enhanced to support Cisco 3800 statistics, UVM and UFM-U statistics for SWSW 8.2.5x based release.
SV+ 8.4.10 does not support Wingz report generator feature for Cisco 3800 nodes. However, the Cisco 3800 statistics are collected and saved in the SV+ database.
SV+ 8.4.10 does not support the ALM-A cards for IGX. As a result, the connections terminated at ALM-A cards will not be shown in the Connection Manager GUI.
SV+ 8.4.10 does not support voice connections. As a result, the connections terminated at UVM cards or FTM cards will not shown in the Connection Manager GUI.
SV+ 8.4.10 does not support ELMI on UFM cards.
The upgrade from SV+ release 8.1.4x (AIX 4.1.4 based) or SV+ release 8.2 (AIX 3.2.5 based) to release 8.4.10 (AIX 4.1.4 based) is supported.
Please refer to the "StrataView Plus 8.4 AIX Installation Guide" for detailed information.
The typical SV+ upgrade procedures include importing the Informix database from previous SV+ release. The user has to check the data integrity of existing SV+ 8.1 or 8.2 database prior to executing the SV+ 8.4 database upgrade procedures. The recommended tool for this purpose is the connmiss program located in /usr/users/svplus/tools directory.
StrataView Plus 8.4.10 supports AIX 4.1.4/4.1.5 on IBM Power PC model 42T or E30.
The recommended system configuration for SV+ 8.4.10 is, any one of the above mentioned workstations, with greater than or equal to 256 megabytes of RAM, two 2 Gigabytes of hard disks, CD-ROM drive, 8mm tape drive, 3 and 1/2 inch floppy drive running AIX 4.1.4/4.1.5, and NetView for AIX Version 4 Server. It is recommended that the system be configured with at least 400 megabytes of swap(paging) space (Paging space should be roughly two to three times of the RAM). The default disk space for the Informix database is 800 megabytes.
The SV+ 8.4.10 release works with IBM NetView Release 4.1 Server for AIX 4.1.4/4.1.5.
For IBM NetView installation requirements and procedures, please refer to "IBM NetView for AIX Installation Guide - Version 4".
The user needs to make sure at least 750 MBytes of disk space in /usr/users/svplus area can be allocated for SV+ 8.4.10 installation. In the case of upgrade, disk space used by existing SV+ software plus free disk space should exceed 750 MBytes.
AIX SMIT Install is used for SV+ 8.4.10. Please refer to the "StrataView Plus 8.4 AIX Installation Guide" for detailed information.
The SV+ upgrade is not supported across different platforms, for example the upgrade from a AIX-based SV+ release can't be upgraded to a Solaris based SV+ release or vice versa.
After performing the creation of a new database, i.e. executing SV+CreateDb command, if StrataView Plus is restarted before it is synchronized with the network, it will result in a database inconsistency. In this case, perform SV+CreateDb before restarting SV+ to avoid database inconsistency.
After SV+ is shut down, the user must wait for at least 10 minutes before restarting it again.
The logical_connection table count for a node in SV+ database may not match the master lcon counts in that node. This will happen if it contains FastPAD connections, or if it has slave lcons with no connections.
Any node with IP address 192.0.0.0 or 0.0.0.0 will not be displayed or stored in SV+ database.
Each IPX/BPX/IGX/Axis node to be managed by StrataView Plus must be configured with an IP Relay IP Address (cnfnwip). The gateway node must be configured with both LAN and IP Relay IP Addresses.
The IPX/BPX routing and IPX/AF feeder modes must be configured with read and write SNMP community names. The SNMP community names "public" and "private" are configured in SV+ for GET and SET respectively as defaults.
The directly attached node (Gateway node) must be configured with IP Relay IP address before starting StrataView Plus.
For adding a connection the connectionIndex must be 0(i.e., there is no need to do a GET on connAvailIndex). The actual index is internally generated by the connection service agent itself.
For the sake of backward compatibility, the 500 series traps are generated for 8.1 or 8.2 nodes, while the 20000 series traps are generated for 8.4 nodes.
For DAS connections, deleting an end point from a segment and later adding it to another segment at a very fast rate may result in a database inconsistency.
Test Connection and Test Delay do not work for connections routed through a StrataCom virtual trunk cloud when the connection originates from an Axis or BPX midpoint.
Connection Manager GUI for preferred route displays ALL available trunks without considering the traffic class. As a result, it is possible to set a preferred route for a CBR connection traversing trunks that do not support CBR traffic.
SV+ shows the status of a connection based only on the routing segment status.
In the Connection Manager GUI, the user must enter both the end points (i.e. node, shelf, slot, port) in the Add Connection window before entering any connection or midpoint parameters.
For an FRSM - ASI PVC connection, the error message "Remote SCR value out of range" generated by the remote BPX, indicates that the CIR value of the Frame Relay side is below the acceptable limit (cell rate) of the trunk between the AXIS shelf and its routing node. To correct the problem, one can increase the value of CIR. E.g., if the trunk between the AXIS shelf and the routing node is a BXM trunk, the CIR value should be at least 19.2 kbps (= 50 cell/sec).
ABR.FS connections cannot be added with default values for ATM-FR SIW connection. The 'ICR TO' value has to be changed.
Certain types of connections, such as VBR.1 or CBR, with policing parameters can't be modified by SV+ if the default was changed using the switch command line interface.
The maximum VCI that can be used for connections is 32767.
The Connection Manager GUI provides the default values of 5100 bytes for BC (Burst Committed) and BE (Burst Excess). These values are suitable for all cases of CIR (Committed Information Rate) up to 2048 Kbps. If the CIR is changed to some value higher than 2048 Kbps, the user should adjust the BC and BE accordingly, otherwise, frames might be "detagged" due to the inappropriate values of BC and BE. The following formula can be used as a guideline for these two parameters: BC = BE = 5100 * (CIR / 2048000).
When the user starts a stand-alone SCM, the following message is not an error message: Cannot communicate with SV+, either SV+ is not active or another GUI is running presently.
The user should select a routing node for the SCM time sync node.
For a group of selected nodes from which stats files are to be collected by a stand-alone SCM, the collection period should be set to the same value for all nodes.
If stats files are being saved, the SCM does not purge these files even if the disk is full.
The SCM supports 3100 nodes maximum in stand-alone mode.
For Cisco 3800 nodes, the network parameter 'Time-out period' has to be 5 seconds.
Prior to SWSW release 8.1 P2, the user is able to specify any time period for a peak interval from SV+. In SWSW 8.4, following rules are used when the user configures peak interval through SV+. Violating the rule will cause TFTP error 22 displayed in the SCM.
While SV+ Desktop is running, if the X server crashes for any reason then SV+ desktop should be restarted.
While SV+ is running, if remote display is killed without properly shutting down the SV+ Desktop then reopening it remotely may not succeed.
Whenever SV+ core processes are stopped, NetView for AIX also need to be stopped, if it is running. To get the proper updates, NetView for AIX should be restarted after the SV+ core processes have been restarted.
A VNS node is not to be attached to feeder nodes.
A VNS node may be added to a node isolated from the network.
The Wingz "Add Comment" option is not supported for virtual trunk and ATM connections. Wingz sometimes does not scroll up the list box properly.
Sometimes it may take 2-3 minutes to display new nodes after addition of virtual trunks. This is due to the time required to setup link0 and link1 subscriptions.
Although SV+ 8.4.10 is designed to be backward compatible with pure 8.1 and pure 8.2 networks, the SIT testing was done only on a pure 8.4 network.
The basic SNMP Agent functionality is unchanged from release 8.2. ATM-ATM and ATM-FR cross connections are supported through the Connection Service Agent.The Port Service Agent will support a physical port addressing for FRSM and a logical port addressing for the rest of the cards. In the case of CESM and FRP, the logical port addressing is identical to physical port addressing. The structure of the SV+ 8.4 service MIB has been re-organized.
The SNMP master agent is configured to use 8161 as a default port id for agent communication. The configuration file SNMPAgent.conf for the master agent is located in /usr/users/svplus/config. If user is running another Network Manager which uses port number 8161, this UDP port can be configured to some other port number in this file as follows:
The Service MIB (Connection Service MIB and Port Service MIB) uses community strings for authentication. The Connection Service Agent and Port Service Agent processes use /usr/users/svplus/config/SNMPProxy.conf file as a configuration file. The SNMP community name strings can be configured in this file as follows:
The SNMP community names "public" and "private" are configured in this file for GET and SET respectively as defaults.
In order to run Wingz2.5 successfully on AIX 4.1.4/4.1.5 user needs to do the following:
Step 1 User should extract Wingz2.5 to /usr/users/Wingz directory. If it is extracted to any other directory, then user has to create a link /usr/users/Wingz pointing to the extracted directory.
Step 2 The extracted Wingz2.5 directory should be owned by user svplus, and group users.
Step 3 User needs to create a link DBLink in /usr/users/Wingz directory which points to /usr/users/Wingz/DataLink/DBLink.(Assuming the Wingz2.5 is extracted in /usr/users/Wingz directory)
The 'telnet' command in AIX 4.x(x>= 1) has the following problem. If it is used to login to any of the StrataView nodes (BPX/IPX/IGX), the login user name and password are not taken properly and the login always fails. The workaround for this is to set the 'telnet' mode to character mode. For this enter the telnet escape character (usually combination of Control key and ']' - left square bracket -keys), which is shown on the screen as soon as the telnet command is given at 'Enter User ID:' prompt. telnet > mode character <ENTER>
<ENTER>
NetView-Network Topology-Objects can be placed out of the screen. But, no way to get them back in the screen. Work-around: Turn the Auto Layout "ON" on all the submaps. This will re-layout the map using NetView for AIX layout algorithms and bring the out of screen objects on this screen.
NetView for AIX refresh map does not work occasionally for READ-ONLY map.
NetView for AIX displays blanks in the filter window occasionally.
ovw binary goes to loop sometimes.
While using Reports feature of StrataView Plus(using Wingz 2.5), 'Window not found' messages appear on screen. These are harmless messages(press OK for the window).
While using Wingz2.5 the Config.wkz or ConfigRep.wkz, worksheets flicker when any of the list box items are selected. This is not a problem.
Sometimes, SV+ desktop does not start giving the Bad Font error. This is a problem with MWM on AIX 4.1.4. When this happens exit the MWM and restart it again, then desktop comes up ok. If the problem still exists perform the following steps:
Step 1 On the machine where you want the desktop to be up, do a xlsfonts and redirect the output to a file.
$ xlsfonts > xx
Step 2 Set the environment variable 'FONT_FILE' to xx.
$ setenv FONT_FILE xx
This will take care of the font problem.
The following two new traps have been added to Axis mib ( axis.mib file in mibs subdirectory of svplus home directory).
50022 - shelfLossLmiAlarmTrap
Indicates the Loss of LMI Alarm for AXIS BNM trunk.
(ANNEX G signalling failure)
50023 - shelfLossLmiAlarmClearTrap
Indicates the Clear of Loss of LMI Alarm for AXIS BNM trunk.
(ANNEX G signalling failure has cleared)
The above traps also have been added to StrataCom_trapd.conf, the NetView/HPOV-SV+ interface file.
The following changes are done in axis.mib (changes from axis.mib release 4.0.03 to 4.0.06).
1. Additional enumerations have been added for the following objects due to introduction of new card types.
shelfFunctionModuleType
redPrimaryType
redSecondaryType
functionModuleType
2. The object dsx3LineType has been changed.
a. Added enumeration dsx3M23(3).
b. Changed access from read-only to read-write.
3. The default value of chanOvrSubOvrRide has been changed from disable to enable.
4. Changed varbinds in traps.
a. Varbind #4 has been changed from shelfSlotNum to moduleSlotNumber for all traps.
b. Varbinds #6 and #7 have been changed for the traps 50000, 50002-50009
shelfFunctionModuleState to functionModuleState
shelfFunctionModuleType to functionModuleType
5. Varbinds #6 and #7 have been changed in the following traps
a. bnmNolinealarmTrapnum (50100)
b. bnmlinealarmTrapnum (50101)
c. bnmLineLpbkEnableTrapnum (50102)
d. bnmLineLpbkDisableTrapnum (50103)
Varbind #6 has been changed from dsx3LineNum to lineNum.
Varbind #7 has been changed from dsx3LineType to lineType.
6. Changes in Descriptions have been done for some MIB objects.
The following changes are done in axis.mib (changes from axis.mib release 4.0.06 to 4.0.07).
1. Modify(3) enumeration has been deleted from SRM3T3 object.
2. Additional enumerations have been added for portState object. These are done as part of BERT related changes.
latchDS0DropFeLoop(9)
latchDS0LineFeLoop(10)
latchOcuFeLoop(11)
latchCsuFeLoop(12)
latchDsuFeLoop(13)
latchHL96FeLoop(14)
v54PolynomialFeLoop(15)
The following changes are done between release 4.0.07 and 4.0.08 versions of axis.mib.
1. The stratacom definition was removed from the MIB. This can be imported from the RTM-MIB instead.
2. NetPrefix definition has been changed. Instead of SIZE(8|13), now it is SIZE(8..13). This clears errors from the smic compiler.
3. Changed bertDDSCode enumerations from HEX to decimal equivalents. This clears errors from the smic compiler.
4. NsapAddress definition has been changed. Instead of SIZE(1 | 4..21), now it is SIZE(1..21). This clears errors from the smic compiler.
5. Trap definitions have been modiefied for the traps 50040, 50041, 50060, 50061 and 50062. In the previous release, the varbind moduleSlotNumber appeared twice in the trap definition, resulting in smic compiler errors. So, to avoid the problem of duplicate moduleSlotNumber varbinds, now the second moduleSlotNumber has been changed to shelfSlotNum.
The following changes are done between release 4.0.08 and 4.0.09 versions of axis.mib.
1. The traps 50120-50123 have been added.
2. The traps 50100-50103 have been obsoleted from Axis release 4.0.
The following changes are done between release 4.0.08 and 4.0.09 versions of axis.mib.
1. The traps 50120-50123 have been added.
2. The traps 50100-50103 have been obsoleted from Axis release 4.0.
The following changes have been done to switch mib (/usr/users/svplus/mibs/strata.mib) and SV+Service.mib.
1. The range of atmEndptMinAdjustICA object has been changed from 1..100 to 3..255.
2. The description of atmEndptMinAdjustICA object has been updated. Following is the new description.
DESCRIPTION
"ForeSight minimum adjustment period. Also known as TRM, which provides an upper bound on the time between forward RM-cells for an active source.
. Units: milliseconds.
. Applicable connection types:
standard ABR, ABR FST, ATFST: VSVD = enable(1)
. Default: 100 "
1. The range of atmEndPointMinAdjustPeriod object has been changed from 1..100 to 3..255.
2. The description of atmEndPointMinAdjustPeriod object has been updated. Following is the new description.
DESCRIPTION
"ForeSight minimum adjustment period. Also known as TRM, which provides an upper bound on the time between forward RM-cells for an active source.
. Units: milliseconds.
. Applicable connection types:
. ABR.1, ABR.FS: VSVD = enable(1)
. Range:
. ASI/BNI T3/E3: 20-250 msec
. BXM: 3-255 msec
. Applicable cards: BXM, BNI, ASI-T3/E3
StrataView Plus 8.4.10 will operate with IPX/BPX/IGX releases 8.4.0, 8.1 and 8.2, Axis release 2.x, 3.x (AUSM4, CESM4, FRSM4, ASC and IMATM) and Axis release 4.0.02 (CESM4, FRSM4, AUSM4, BNM T3/E3, BNM 155, SRM T1/E1, SRM 3T3, IMATM and FRSM8) for all supported features.
StrataView Plus 8.4.10 has been tested with IPX/BPX/IGX release 8.4.0 and Axis release 4.0.02.
StrataView Plus 8.4.10 will be backward compatible with AXIS release 3. In the case of IMATM, StrataView Plus 8.4.10 will fully support IMATM starting on IMATM release 3.0.03 onwards. The support for any previous releases of IMATM is limited to display on Equipment Manager. No other support is available from SV+.
Although SV+ 8.4.10 equipment manager shelf view displays AUSM release 2 cards, the user needs to enable the line and ports from AUSM CLI. The Equipment Manager line configuration window and port configuration windows will not fully functional for AUSM R2 cards.
StrataView Plus 8.4 Connection Manager does not support AUSM R2 due to the lack of port speed information in the SV+ database. This limitation will not allow the user to specify the PCR(0+1) parameter related to AXIS.
StrataView Plus 8.4 does not support the BERT feature of AXIS/SRM R4. The user has to use CLI interface to configure the BERT functions.
The following is the list of known anomalies in this Cisco StrataView Plus software release.
Bug ID Descriptions
CSCst97513 DNS trap number 7012, 7014, 7015 are shown in the rtm.log but not in HP Openview/NetView event log.
CSCdj23550 The Connection Manager GUI provides the default values of 5100 bytes for Bc(Burst committed) and Be (Burst excess). These values are suitable for all cases of CIR(Committed Information Rate) up to 2048 Kbps. If the CIR is changed to some value higher than 2048 Kbps, the user should adjust the Bc and Be accordingly, otherwise, frames might be "detagged" due to the inappropriate values of Bc and Be. The following formula can be used as a guide line for these two parameters: Bc = Be = 5100 * (CIR / 2048000). The workaround is specifying correct Bc and Be parameters in the case of CIR > 2048 Kbps.
CSCdj24615 SV+ should use higher time out value for BRAM save/restore application. Current application level time out value is 1 minute which is the same as the robust protocol level time out value. The workaround is the user has to restart the BRAM save/restore process when the protocol transmission is not reliable.
CSCdj31076 The Frame Viewer program which pops up when SV+ desktop is launched remains on after SV+ core processes have been stopped and desktop has exited. The impact is some amount of memory occupied by the Frame Viewer process. The workaround is the user manually kills the Frame Viewer process after SV+ core processes have been stopped.
CSCdj38135 On any axis card, upon bringing up the line menu, if any of the
lines are disabled then the "operational state" displays "disabl" and not
"disabled".
CSCdj40594 The ConnProxy can not be used to "unset" a preferred route. This is typically done by setting the preferred route to NULL.
CSCdj68477 The value of svPortAlarmTable from Service MIB and port status on switch do not match for BXM cards.
CSCdj69154 The Frame Viewer program which pops up when SV+ desktop is launched remains on after SV+ core processes have been stopped and desktop has exited. The impact is some amount of memory is occupied by the Frame Viewer process. The workaround is the user manually kills the Frame Viewer process after SV+ core processes have been stopped.
CSCdj72731 Wrong err msg shown (End Pt. does not exist), if out of range parameters are given for FR-ATM PVC on BXM card, while setting the PVC using SNMP proxy agent.
CSCdj73647 When SV+ Desktop fails to start, the error message given is not clear. The message includes two possible reasons for the failure.
CSCdj76510 Real Time Counters not accessible from the StrataView proxy agents, but the proxy documentation says that they are accessible.
CSCdj79083 After TestCon if a SNMP GET operation is done on svConnLocalStr and svConnRemoteStr objects ConnProxy returns NULL.
CSCdj83866 NWTopology process exits intermittently in an unexpected way.
CSCdj81530 Specifying a value more than 255 for atmEndPointVpi for BXM card as part of the ConnProxy script results in an error.
CSCdj88137 TestCon returns erroneous data in SNMP for FR-ATM PVC. The returned values do not match with the values described in SV+Service.mib file.
CSCdj88286 TestCon on FR-ATM PVC is available through SNMP Proxy agent, but Connection Manager GUI does not allow.
CSCdj88324 If time Sync to a node times out the next node from the node table in the same subnet is tried as alternate time sync host. While trying this the type of the node is not checked (routing/feeder).
CSCdj83876 The Connection Manager GUI does not allow the CDVT(0+1) parameter to have a value larger that 250,000 micro seconds for BXM ports. The maximum value supported by the BXM cards is 5,000,000 micro seconds.
As a work-around for the above problem BPX CLI can be used to adjust the CDVT(0+1) parameter if the value > 250,000 usecs is desired.
CSCdj84198 The treatments of failed connection in the case of Testcon and TestDelay by Connection Manager GUI and Connection Proxy Agent are not consistent. When the connection is in the "Failed" state, the GUI still allows the Testcon and TestDelay operations to be performed on the connection. However, the proxy agent would not attempt the operations, but instead, generate an general error.
CSCdj85527 SV+ install script overwrites the perl executable in /usr/local/bin with the version bundled StrataView media.
CSCdj88210 SNMP Proxy Agent dose not send cardAlarmTrap, when a BXM front card is removed.
CSCdj88215 Incorrect trapReason#3025 (card inserted) will be sent when a BXM back card is removed.
CSCdj88443 Equip Management GUI and SNMP Proxy agent return wrong value for chanSecUpTime counter
CSCdj89302 SCM doesn't give any warning message while exiting, that the stats collection will be stopped.
The following conditions have been corrected in the 8.4.10 version of the software release. In addition, all corrections applied to previous 8.4 releases are included in this release.
Bug ID Descriptions
CSCdj24454 downld program rejects requests even if it doesn't have any active download sessions. This could happen when there is lot of network traffic generated due to multiple download sessions, and some of the sessions may end up in above state.
CSCdj28230 Shared memory values for feeder node ids are wrong and also some of the SV+ processes like databroker etc. would suddenly exit with an error. This can happen if Desktop is started before all the links are up or having ESP and/or ACCESS nodes in the network.
The workaround for the wrong feeder ids in the Network with no ESP or Access nodes is to start the SV+ Desktop after all the links have come up. However, there is no workaround if the Network has ESP or Access nodes, and SV+ process like databroker etc. start exiting.
CSCdj39053 Using dbexport tool of Informix to export StrataView Plus DB stratacom, results in a failure with 'Illegal Stored Procedure Entry'. All the stored procedures used by StrataView Plus have been updated with the fix.
There is no workaround for the above problem. However, this message can be ignored as it doesn't seem to have any adverse effect on SV+ DB creation. User needs to run /usr/users/svplus/bin/create_sp program manually after importing the DB, if manual DB export and import operations are being done using Informix DBATools.
CSCdj40746 statsmain and statschild processes have been enhanced to validate stats file checksum and re-get file if validation fails.
This problem only happens on BPG/IPX/IGX running software version 8.4 or later.
CSCdj41663 For SCM, statsenablelist.stats & enable.master.81.stats files are changed to use defaults and enable.master.81.stats has been fixed to match with statsenablelist.stats file.
CSCdj41747 A problem in RtmProxy that walking the lineGroup object in StrataView Plus Service MIB results in "General Failure Error", has been fixed.
This problem happens only if there is more than one circuit line on the IPX/IGX.
CSCdj41775 The 500 trap, which is sent for connection alarms from BPX/IPX/IGX, has a new value '5' defined for svConnType in StrataView Plus Service MIB and related changes in emsc. The same is done for trap 20000 also.
CSCdj41906 Unable to disable VS/VD feature for BXM-BXM ABR.1 connection by using Connection Manager GUI nor SV+ SNMP proxy agent. This problem only occurs on BXM-BXM ABR.1 connections. Once such a connection is added through the GUI/Proxy agent, the VS/VD feature of the connection cannot be turned off. The workaround is delete the connection and then create it again with the desirable VS/VD turned off.
CSCdj42722 Cannot get Physical to Logical map on FRSM connections. This problem effects the Port Proxy Subsystem only.
CSCdj42728 'status' field in 'packet_line' table is being populated with'0' value. The status field will now be correct. This effected the topology packet_line table and had no visual effect on the SV+ GUI or topology maps.
CSCdj42760 Cannot add cons with ICRTO > 8000. The range has been updated to be up to 250 seconds or 250000. This effects the Connection Proxy subsystem and the MIB comment.
CSCDj42895 PortProxy exits under heavy system Loads. This problem correction only effects the Port Proxy subsystem only.
CSCdj42987 Cannot add FR-FR cons from SV+ 8.4 managing 8.2 network, using ConnProxy.
CSCdj43616 Memory config of greater than 256 but less than 512 Megs memory get "Out of Shared Mem" error.
CSCdj45001 "maintlog messages not converted to traps".
The maintlog messages are sent directly to eventd, who converts them to traps and sends them ONLY to OpenView/NetView (trapd). The robust object alarms, are processed by emsc, sent to eventd, who converts them to traps and sends them ONLY to RtmProxy.
The problem was that the process emsc was checking the status of the robust object alarm with the current status for that object. If they were the same, a duplicate alarm was assumed - even though they could have different "reason" codes. The change/fix is to not do this checking.
CSCdj45010 Cannot modify connection on a FRP card in 8.2 network, when the modify command is given using ConnProxy from a SV+ 8.4 station, other than the one from where the connection has been created.
CSCdj45470 A problem in statsparser, where it aborts parsing stats file when there is more than 127 stat types enabled for one object instance, has been fixed .
CSCdj47539 Multiple statsparser processes are running at a given instance on a StrataView Plus station. There are now two differently named processes - statsparser and statsager which are both independently started/stopped by the watchdog process.
CSCdj47926 "database current and preferred route strings missing nodenames"
The problem was that the emsd process was corrupting its cache and the database due to a problem reading large topology messages from the topod process.
CSCdj49165 When adding a intra-switch frame relay connection on an IPX/IGX routing node using ConnMgr or ConnProxy, the switch will reject the request if the percent utilization parameter is set to any value other than 100. This problem now has been fixed in cmgrd.
Workaround for this problem is not to set the percent utilization parameter when adding such connection using ConnProxy. If ConnMgr GUI is used, not to change the percent utilization parameter from its default value of 100.
CSCdj49244 The log files of SV+ processes in /usr/users/svplus/log directory show year portion as 100 and ImageDownLoad window from NetView/OpenView menu also shows 100 in date stamp of images, when system's date is changed to year 2000.
CSCdj49457 When INS station icon is dragged into NetView/OpenView map, the following error message appears on SV+ terminal.
"Ilb Error Function void ::msgPort(InsMsgHeader*) not exported by SVOV949.pid949@daslab8.
Ilb Fatal Error Mismatch between versions of ILB generated protocol.
INSD process gets restarted due to the above error.
CSCdj49468 Clicking the "Refresh" button on the Connection Manager GUI main window after the transition between "Normal" and "ANI/Dial up" modes may cause the GUI process to exit occasionally.
The workaround for this is to first click the "Apply" button to enforce the filter setup before using the "Refresh" button.
CSCdj49612 cmgrd process may get disconnected from databroker process for long time and gets reconnected on its own after sometime.
This can happen on networks with more number of feeder nodes.
The above problem happened because databroker process is busy reading its messages in the memory sent by topod process, to respond to cmgrd process when cmgrd tried to check its connection with databroker.
CSCdj50252 When a MOD(ify) operation is performed on ICRTO value of an existing connection using Connection Proxy the following error is generated
"Invalid Value[value] for atmEndPtICRTO"
The only workaround for the above problem is to delete the connection and add it again with desired value of ICRTO.
CSCdj50369 INS ANI Configuration window does not come up when it is started from SV+ menu (option 8), even when INS is installed.
The workaround for this is to open an 'xterm' and run insAniConfig.
CSCdj50377 Scroll bar in connection list window of Connection Manager GUI disappears, when an ANI is selected in Dial Up window and Apply button is clicked.
The workaround for the above problem to exit Connection Manager GUI and restart it.
CSCdj50479 An intermittent problem in tftpchild process, where uploaded config files in current session are corrupted, if the previous tftp session had error timedout.
CSCdj50752 Network Topology application shows only the configuration saved date of the saved configuration ID, when it is selected from "Images->Config ..." screen. It doesn't show the BRAM ID and Node name information of the saved configuration.
CSCdj51047 Can not add 1-1 redundancy to FRSM-HSI cards on Axis shelf, using SV+ Equipment Manager GUI.
The workaround for this is to use addred command from Axis CLI.
CSCdj51831 When clicking on the NWTopology map on a multiple trunk line to open up a multiple trunks window the following message is displayed on SV+ start-up terminal.
"Warning
Name popup
Class XmForm
Top attachment widget for widget named 'list_label' (class XmLabelGadget) must not be null."
However, this warning message doesn't effect any functionality of the Network Topology map.
CSCdj52061 The configuration file for watchdog process, watchdog.conf becomes empty or is completely removed when the SV+ Proxy processes are killed at the same time.
The above problem happens only when the proxy processes are killed manually in one kill command or SNMPAgent process is killed before the proxy process.
The workaround for the above problem is not to manually kill these SV+ Proxy processes. Stopping SV+ will terminate these processes without this problem. Another alternative is kill the proxy processes one by one and kill SNMPAgent last.
CSCdj54165 Modifying or deleting a PVC might fail with an error message "No SUCH NAME" for certain configured node names. The problem only occurs in cmgrd process, if the node name is configured as "D" or "Dx" where x is any alphanumeric character.
The workaround for this is to change the node name to a string at least 3 characters long or use any character other than 'D' as the starting character.
CSCdj52243 "packet_line table has corrupted entries".
The packet_line (trunk) information is reported to SV+ in two ways. First, topology messages contain packet_line information and are processed by the topod process. Second, there are robust object/alarm messages that are processed by the emsc process. The problem was that the emsc process was sending updates to the topod process, which was causing the topod process to corrupt it's cache and the database. The fix is to stop the emsc process from sending packet_line updates to the topod process.
CSCdj53355 The Test Delay operation is not available from Connection Manager GUI on a connection with both end points on the same switch (DAX connection).
The workaround for this is to run tstdelay command on switch.
As a result of the fix for above problem user will be able to click on 'Test Delay' button in Connection Manager GUI, after selecting a DAX connection. However, the 'Test Delay' may or may not be successful depends on the support by switch for that type of connections. Currently 'Test Delay' on DAX conns is supported by BPX, but not by IPX or IGX.
CSCdj53956 EMGUI doesn't show SRM in slot 16 until a node resync. This happens in networks with SV+ 8.4.xx where xx < 09 and Axis FW release 4.0.0x where x < 4. StrataView portion of fix has been done in Equipment Manager GUI and AXIS fw release 4.0.04 has AXIS fix.
CSCdj53960 After core card switch SRM card can not be configured from Equipment Manager GUI.
The work-around for this is to remove the card entry for that slot from SV+ database and do a node resync from Equipment Manager GUI.
CSCdj54384 Modifying PIR parameter value of FR-FR PVC fails as RIF parameter of the connection is not adjustable. The problem is fixed in cmgrd process.
The workaround for this is to use the CLI on switch to lower the RIF value.
CSCdj55784 When a tftpchild process is killed tftpMgr process kills all the remaining tftpchild process, and restarts them. This problem has been fixed in tftpMgr process.
CSCdj55790 The rtm process is taking longer time to inform topology applications of the DAS/INS station status update (UP/DOWN).
CSCdj57299 Inconsistent display between AXIS CLI and Equipment Manager GUI clock config screen. This problem only occurs with release 3 BNM card.
CSCdj59417 An intermittent exit problem in statsparser has been fixed. This happens due to some internal memory corruption.
CSCdj59754 Modification of atmEndPointPolicing for ATM endpoints using SNMP Proxy fails. The following variables also have similar problems:
atmEndPointNRM
atmEndPointTBE
atmEndPointFRTT
atmEndPointVSVD
This has been fixed in in ConnProxy process.
CSCdj59952 When using the MIB browser in OpenView/NetView for BPX node in the StrataView map, the nodename is postfixed -bpx. As a result MIB browser doesn't understand if this name is given.
In release SV+ 8.4.10 in the routing level map, all bpx nodes label and selection names are constructed from node names sufixed with "-hub". In the feeder level map, the label and selection name of the core shelf are the same as the node name. User has to select the core shelf for the bpx node in the feeder level map to launch Mib Browser. For IPX, IGX and AXIS, user can select the respective node and launch Mib Browser. The name/ip address displayed in the MIB Browser will be correct.
As a work-around for the above problem the core shelf for the bpx node can be selected from the feeder level map. Then from the Misc menu, if SNMP Mib Browser is selected, the name/ip address displayed in the MIB Browser will be correct.
CSCdj60485 An unexpected exit problem in emsc process has been fixed. This can happen if SV+ station is attached to IPX/IGX network with FTM/FTC cards.
CSCdj60520 NWTopology process exits in an unexpected manner. This can happen when user clicks on trunk 2 in the topology map, after double clicking on the same trunk and then clicking on Cancel when 'Trunk Description' window shows up.
CSCdj60587 strata.mib doesn't get loaded into NetView by StrataView install program.
The workaround for this is to load strata.mib using options from NetView menu.
CSCdj62427 Connection status and Abit status shown in Connection GUI, doesn't match with their status on the switch or axis shelf. This happens usually if the connections are added when the axis shelf is under LMI failure.
CSCdj62505, CSCdj63377 SV+ processes gets unregistered intermittently with all the AXIS shelves. This happens only in the networks having large number of AXIS shelves with lots of activity. This problem has been fixed in rtm and databroker process. With this fix databroker directly sends the user connection traps to trapd and RTMProxy, instead of routing them thru rtm. This will reduce the load on rtm and will avoid above problem occurrences.
The workaround for the above problem is to kill snmpcomm process or to stop and start StrataView Plus.
CSCdj63341 After SV+ warmstart, when Connection Manager GUI is started it pops up a message that shared memory is not accessible and the customary node list is not shown. This problem has been fixed in topod process.
This can happen on systems where several Network Topology (NWTopology) processes are running and being stopped and restarted.
The workaround for the above problem is to kill all the Desktop processes, bring up one, wait until the node list is seen in Connection Manager GUI, and bring up other Desktops.
CSCdj63598 Setting peak interval same as the bucket interval to collect statistics as mentioned in StrataView release notes, will result in Cell Tx and Rx stats collected with wrong value. The documentation problem has been fixed in StrataView release notes.
The workaround for this is to restart collecting stats with a peak value less than the bucket interval.
CSCdj63905 Equipment Manager GUI does not reflect the correct color for administrative state on SRM3T3 in release 4 AXIS shelves. This problem happens because of improper handling of the related trap by emc process.
The workaround for this is to do a node resync from Equipment Manager GUI after disabling the line.
CSCdj64646 Display of the real time counters from EMGUI does not get updated if the port/channel number is changed in the input window. The counters shown are still related to the port/channel previously entered. This problem has been fixed in Equipment Manager GUI.
The work-around for the above problem is to stop and start Equipment Manager GUI.
CSCdj65376 EMGUI real time counter do not match the counter on Axis shelf. This problem has been fixed in Equipment Manager GUI.
CSCdj65933 EMGUI does not show alarms on SRM card in Axis shelf running 4.0.04. This problem has been fixed in Equipment Manager GUI.
The workaround for the above problem is to look at the line alarm, and then go to individual line screen and look at the alarm state.
CSCdj66288 A problem in topod process, which causes SV+ database inconsistency by leaving some of the deleted trunks in the database has been fixed. This happens only if trunks are deleted using 'deltrk' command on CLI, when SV+ is down and not using 'dntrk' command after 'deltrk' command.
Workaround for this problem is to do 'dntrk' command on the spurious trunks using CLI.
CSCdj66348 A problem in ConnectionManager GUI, where it incorrectly shows ICR TO ADTF unit in seconds, has been fixed. This is shown in both ATM-ATM ABR.FS and ATM-FR ABR.FS provision windows.
CSCdj66681 On certain systems after auto installing StrataView, an attempt to start SV+ fails with message "error - unable to initialize shared memory".
The workaround for this to run INSTALL program in StrataView home directory as user root after editing the /etc/system file to delete the duplicate entries, leading white spaces and rebooting the system with 'reboot -- -r' command as user root.
CSCdj67625 PortProxy process returns incorrect results for svPortAlarmTable variable, if a get next query is done for ports on AXIS FRSM-8 and FRSM-HS1 cards.
CSCdj68460 PortProxy process doesn't show status of AUSM-8 ports, if a snmpwalk is done on svPhysicalToLogicalMapTable. This problem has been fixed in PortProxy.
CSCdj68473 Statistics for FRM/CVM T1 circuit line can not be collected. This problem has been fixed in statsparser.
CSCdj69022 The mib object svFrPortStartingCh in the svFrPortTable is listed as "Read/Write" for FRSM-4, FRSM-8 and FRSM-HS1 card. However, no matter what value you set on svFrPortStartingCh, the value you get back on snmp get is always the same as that of svFrPortPort. Similar problem exists for svFrPortLine. In this case, the value returned is that of svFrPortLineIndex.
The above problem happens when attempting to set the mib objects svFrPortStartingCh and svFrPortTable on AXIS FRSM-4, FRSM-8 and FRSM-HS1 card using PortProxy process.
CSCdj69146 An intermittent problem in cmgrd and databroker processes which blocks PVC provisioning. The problem only occurs when PVC provisioning is happening non-stop while the databroker process is busy processing topology messages or alarm messages.
As a work-around, warm start of the SV+ core will gracefully cause the back-end to recover.
CSCdj69172 A problem in topod process, where it leaves some entries in the trunk table of SV+ database with no endpoints or wrong endpoints. This only happens if trunks are moved on the network ( by holding one endpoint constant and changing other), while SV+ is not running.
CSCdj69756 PortProxy process intermittently returns wrong value for the variable svPortCardType, for the GET requests.
This problem only happens if the GET request contains variables from multiple tables.
CSCdj70378 Selecting real time counters display make Equipment Manager GUI to terminate in an unexpected manner. This problem has been fixed in Equipment Manager GUI. This happens only if the channel counts are selected before the port counters.
The workaround for the above problem is to select and display port counters before the channel counters.
CSCdj70381 Connection Manager GUI does not reflect correct connection status of AUSM 8T1. This problem has been fixed in emc.
The connection manager shows either a "OK" or "OK/A-Bit Alarm" status on the connections instead of "Fail/A-bit" status. if a LOS is caused on a port on 8T1 AUSM.
CSCdj70786 The snmpcomm process might exhaust its resources intermittently and blocking the user to perform test con/test delay thru Connection Manager GUI. This problem only occurs when a relatively large no. of Connection Manager GUI's were restarted after running test con/test delay operation.
The work-around for this problem is stop and start SV+.
CSCdj70855 An intermittent and unexpected exit problem has been fixed in emc process.
CSCdj71053 SV+ INSTALL gives error messages like 'grep cannot open /tmp/swap.*' etc.
This happens only in SV+ DB configurations where there is more than one disk involved.
Workaround To create a dummy file (0 byte) with the same name as it is shown in the error message, without interrupting the INSTALL. This can be done from a different terminal and it has to be done whenever the error message is shown in the INSTALL window.
CSCdj71731 A problem with Connection Manager GUI where it shows incorrect user connection status and also fails to show some of the connections has been fixed.
This happens when the user deletes a channel on AXIS shelf where there are some more channels on the same slot with the same physical port number and DLCI.
The workaround for the above problem is to do a node resync operation on the AXIS shelf from Equipment Manager GUI.
CSCdj71795 Functional inconsistencies between some of the objects in SV+Service MIB and EquipmentManager GUI have been fixed. The fixes have been done SV+Service.MIB and PortProxy process.
The updated MIB objects are svFrPortCLLMEnable, svFrPortCLLMTimer, svFrPortAsyncUpd, svFrPortPollVerTimer, svFrPortErrThresh, svFrPortMonEveCnt, svFrPortLinkTimer, svFrPortPollCycle. After these modifications the above attributes on a port are no longer modifiable thru PortProxy, if the signaling protocol on the port is disabled.
CSCdj72186 An intermittent exit problem in tftpmgr process has been fixed.
CSCdj72187 An intermittent exit problem in configSave process has been fixed. This problem happens only if configSave receives a SIGTERM signal. This could be caused by exiting HP-OV ovw while configSave is still running.
CSCdj72188 An intermittent abnormal exit problem in Equipment Manager GUI process has been fixed. This problem has been observed to be happening usually after using real time counter screen for long time, to view counters on Axis AUSM and FRSM cards.
CSCdj72220 Inability to change CLLM xmt status timer alone for FRSM cards using EquipmentManager GUI. This problem has been fixed in EquipmentManager GUI.
The workaround for this problem is to disable CLLM first using AXIS CLI and then enable it and change the Xmt status timer at the same time.
CSCdj72753 The documentation error regarding atmEndPointMinAdjustPeriod object in SV+Service.mib has been fixed. The range now has been changed to 3 to 255.
CSCdj72953 When the selected/highlighted connection on the Connection Manager GUI main window has a change of state event, the PVC would become deselected/un-highlighted. This problem has been fixed in Connection Manager GUI.
The work-around for the above problem is to select/highlight the connection.
CSCdj72989 An attempt start SNMPAgent from SV+ menu results in the following error messages.
" Unable to start SNMPAgent
Unable to start ConnProxy
Unable to start PortProxy
Unable to start DasProxy
Unable to start RtmProxy"
This happens only if SV+ INSTALL programming has been run after installing SNMPAgent software.
The workaround for this is to run INSTALL_AGENT program in /usr/users/svplus directory as user root.
CSCdj73570 Setting up or updating a ATM-ATM/ATM-FR connection using ConnProxy process fails, if atmEndPointMBS parameter given is more than 24000.
CSCdj73910 Inability to delete INS node from a OpenView/NetView map. This problem has been fixed in topod process.
This problem happens only if INS and INSD nodes are added in one session of NetView/OpenView, and trial to delete INS node made after stopping and starting SV+. This results in "No active INSD present. Can't delete INS node" error message.
CSCdj75824 Enumeration for 4001 was missing from trapReason field in SV+Network.mib. So when "Power supply clear" (defined as 4001) TRAP was sent to user from SV+ with 4001 reason field value, he/she could not map it to any value.
This has been fixed in SV+Network.mib file by defining 4001 as "Power supply clear" reason field.
CSCdj76442 SV+ INSTALL gives error messages like "'/usr/sbin/prtvtoc -h $i | awk '{print $5}' Ambiguous input" etc.
This happens only in SV+ Patch1 or Patch2 configurations and only if non meta devices ( no /dev/md/* /dev/vx/* ) are used to configure DB partitions.
CSCdj77420 An enhancement has been done to Connection Manager GUI to include logical and the corresponding physical port information for the all the port types, in SlotPortHelp list.
Prior to this enhancement, the SlotPortHelp list used to display all the FRSM ports in physical notation i.e., <physical line no.>.<Starting DS0 channel no.>, and all the other ATM/FR/CE ports in logical notation.
The work-around for the above exists only for Axis shelves. For Axis shelves one can always invoke Equipment Manager GUI to display the port list of a selected slot. The port list includes both the logical and physical notation
CSCdj77436 SCM may not collect statistics files 12 collection cycles back if the history files are set to >= 12. This problem has been fixed in statsmain process.This problem only occurs if the number of history files to collect is set to >= 12.
CSCdj78846 Unable to collect the following statistics via TFTP from BXM trunk lines when selected from SV+ stats manager:
T3 Trunk
41) BIP-8 Errors
98) Frame Sync Errors
197) Tx NTS Cells Discarded
198) Tx Hi-Pri Cells Discarded
199) Tx Voice Cells Discarded
200) Tx TS Cells Discarded
201) Tx BData A Cells Discarded
202) Tx BData B Cells Discarded
203) Tx CBR Cells Discarded
204) Tx ABR Cells Discarded
205) Tx VBR Cells Discarded
E3 Trunk
41) BIP-8 Errors
197) Tx NTS Cells Discarded
198) Tx Hi-Pri Cells Discarded
199) Tx Voice Cells Discarded
200) Tx TS Cells Discarded
201) Tx BData A Cells Discarded
202) Tx BData B Cells Discarded
203) Tx CBR Cells Discarded
204) Tx ABR Cells Discarded
205) Tx VBR Cells Discarded
(98) Frame Sync Errors and
(141) FEBE Counts can be configured for a T3 trunk but don't appear for an E3 trunk.
(170) Loss of Cell Delineation can be configured for an E3 trunk but doesn't appear for a T3 trunk..
Further explanation of the problem:
Frame Sync Errors
As of today, On E3 trunks only Direct Map mode OR HEC framing is supported. With this type of Line Framing "Frame Sync Errors" are NOT supported.
Loss of cell deliniation
If the Line Framing was SET to HEC framing by doing cnftrk, ONLY then this stat is valid. When it is configured in the PLCP mode, this count is not valid.
FEBE Count
This fix is done in Switch Software.
The rest of the missing counters are fixed in Starata View SCM.
CSCdj79397 A problem in emc process, which causes DB inconsistency has been fixed. The above problem causes SV+ DB to have multiple entries in connection table with same node.slot.port.dlce and when only one of them actually exists on the node. This problem happens only if connections are added or deleted when SV+ is down.
The work-around for this problem is to stop SV+, recreate SV+ DB and to restart SV+.
CSCdj80656 An intermittent and unexpected exit problem with emc process has been fixed. The above problem has been observed with SV+ 8.4.09 Patch2 software.
CSCdj80718 A problem in emc process, which causes SV+ DB inconsistency by showing some of the deleted connections in user_connection table but not in connection table. The above problem has been observed with connections on Axis FRSM cards.
The work-around for this problem is to
1. stop SV+ core, run conmiss program in /usr/users/svplus/tools directory, and re-start SV+ core
2. stop SV+ core, re-create the database, and re-start SV+ core.
CSCdj81657 A problem in emsc process, where it updates card table in the SV+ DB with a erroneous value '0' for the card state value. This has been observed with BNI/BXM cards only.
CSCdj81658 An internal problem in Connection Manager GUI process has been fixed for it not to depend on the line values from the frp table for error checking of FRP/FRM/UFM ports. As a result of this problem FRP ports are not shown in SlotPortHelp screen.
CSCdj81728 The real time counters screen in Equipment Manager GUI gives incorrect value for AIR in frsm port counter. This problem has been fixed in Equipment Manager GUI.
CSCdj82171 The percent utilization value reported by the Connection Manager GUI/Conn Proxy Agent might be reported as -1 occasionally. This problem has been fixed in databroker process. This problem only occurs when the 8.4 SV+ is managing an 8.2 network.
CSCdj82198 An intermittent problem in the cmgrd and databroker processes which blocks the PVC provisioning process. This problem only occurs after the Connection Manager GUI was exited and restarted more than 200 times.
As a work-around for the above problem, a warm start of the SV+ core will gracefully cause the back-end to recover.
CSCdj82416 An intermittent abnormal exit problem in ConnProxy process has been fixed. This problem is experienced when the SNMP Agent gets detached from ConnProxy, and subsequent reconnection fails during SV+ shutdown.
CSCdj82504 The time stamp of traps from RtmProxy is different when its first received as compared to the recovered trap. This problem has been fixed in RtmProxy process.
CSCdj84308 Wingz Raw Data Report shows multiple "line 255" entries for T1 service line. This happens only if the node has multiple FRP-T1 cards. This problem has been fixed in util_ext process and Wingz command files.
CSCdj84552 An intermittent problem in Connection Manager GUI where complete connections will be shown as incomplete, has been fixed. The above situation occurs when the ILOG connection between emd and databroker gets into an invalid state which makes emd think that it is not connected to databroker.
As a work-around for this, emd process can be killed, which will eventually be started by watchdog process.
CSCdj84905 Documentation problem related to stats "Total Cells Tx to Line" in and "ATM Cell Header HEC Errors" StrataView database schema documentation has been fixed.
The "Total Cells Tx to Line" stat is not supported in AXIS shelf for trunk/line. AXIS shelf only supports this stat for port.
The "ATM Cell Header HEC Errors" stat is supported in SCM as well as in the AXIS shelf.
CSCdj85874 BXM port status will not get updated in the asi_port table for BXM cards except for BXM having card type 117. Also, there won't be any BXM port alarm generated by SV+. This problem has been fixed in emsc process.
CSCdj87239 Trunk comments get truncated periodically. This problem has been fixed in NWTopology process.
The following conditions have been corrected with patch 1 to the 8.4.07 version of the software release. In addition, all corrections applied to previous 8.4 releases are included in this release.
Bug ID Descriptions
CSCdj40431 The SCM randomly skips stats collection data files (not make a tftp request), due to statsmain process not being able to communicate with any of its child processes whose process id is more than 32K
The following conditions have been corrected with the 8.4.07 version of the software release. In addition, all corrections applied to previous 8.4 releases are included in this release.
Bug ID Descriptions
CSCdj01722 SV+ database counts and alarm states were not consistent between two SV+ stations. This problem was found once during stress test in the large network. However, follow up tests could not reproduce similar problem.
CSCdj01109 SV+ statsparser coredumped when reading Unix password file (/etc/passwd). This problem has been reported to Sun Microsystems for investigation. This problem was found once in SIT.
CSCdj21534 The CMGUI takes a long time (about 25 minutes) to show a large number of connections (about 7000 connections) in the connection list.
CSCdj21366 Sometimes SV+ port proxy coredumped on handling a non existent IPX X.21 backyard. (MR72342)
CSCdj17225 There is a problem of displaying correct Line trap information
(501). The information in slot, idstring, status, severity fields are
incorrect. (MR972248)
CSCdj17240 There is a problem of displaying correct Port alarm information
(503). The information in status and severity fields are incorrect. (MR972249)
CSCdj17251 There is a problem of displaying correct Trunk trap information
(502). The information in status and severity fields are incorrect. (MR972251)
CSCdj15683 The fc_state field is not correct in the SV+ database. (MR972211)
CSCdj15391 The line information is missing from EMGUI for those cards
support physical port scheme. (MR971849)
CSCdj15564 Sometimes the remote per_util of a connection is stored as 0 in the
user_connection table when it should be non zero. (MR972262)
CSCdj19368 There is problem of displaying correct status field information for
20k series traps. (MR972290)
CSCdj19371 There is problem of displaying correct status and severity fields
information for 25k series traps. (MR972290)
CSCdj00196 The user is not able to change the frame relay signalling from
Annex DNNI to no signalling through EMGUI. (MR971858)
CSCdj11457 The rate up (RIF) parameter of a ABR foresight connection is not
calculated correctly. (MR972086)
CSCdj27225 eqpmgr core dump, while viewing Line Alarms.
CSCdj15678 The nwip_on option for savecnf command does not work with 8.4.01 IPX feeders. (MR972220)
CSCdj20689 Sometimes databroker restarted without sending a trap to the user.
CSCdj19360 Sometimes there is a problem of showing correct PVC status in CMGUI and EMGUI/alarm view. The CMGUI failed to show an A-bit problem.
CSCdj25970 The SNMP object svFrPortSpeed in 8.4 is not matching with 8.1 for set/get results. One uses units of kbps, the other uses 100bps.
CSCdj19575 The trapCardType for BXM-12T3 is not supported in SV+MIB and schema.
CSCdj20902 Sometimes CMGUI does not show connections of a failed IPX port.
CSCdj22291 Sometimes incomplete connection not showing in CMGUI. This problem is intermittent.
CSCdj27485 cmgrd core dumps occasionally during multiple delete requests
CSCdj08401 The SV+ Service MIB should be enhanced to support following ATM parameters: CLPHighThresh, CLPLowThresh, EFCIThresh, IBS and VCQ size.
CSCdj29021 Sometime the number of user connections between two SV+ stations managing the same network do not match. This problem observed on a 8.2.50 based network only.
CSCdj33564 Sometime the connection states for AXIS connections are showing up as "OK/Abit failed" when they are actually "FAILED/Abit failed". The line on the axis shelf is in alarm state.
CSCdj33872 When the user performs MIB walk (from NetView/HP OpenView) on the
svNodeGroup of SV+ Service MIB for an IPX/IGX/BPX node, the process stops at
MIB object svNodeGrpName. This problem does not impact SV+ management
applications. The workaround is querying these MIB objects individually from
NetView/Hp Openview.
CSCdj36017 Sometime cmgrd process core dumps at deleting one segment
incomplete AXIS connections.
CSCdj37361 SV+ does not process traps sent from Axis Shelves with IP Addresses
defined as X.0.X.X format where X is a non zero number. The impact is the user
can't assign X.0.X.X format for AXIS IP address.
CSCdj39399 The back card type was recorded incorrectly in the SV+ database
card table. This problem exists for all back card types.
CSCdj33142 Following alarms were not available from SV+: BCC restarted due
to system reset, BCC restarted due to a power failure, CC redundancy, Y
redundancy and communication break for a node.
CSCdj39189 The SV+ Solaris installation script specifies incorrect device name
for CD device and it asks the user to rewind CD device.
CSCdj37451 There is a problem of populating current routes through SNMP get
requests.
The following conditions have been corrected with the 8.4.06 version of the software release. In addition, all corrections applied to previous 8.4 releases are included in this release.
Bug ID Descriptions
CSCdj01722 SV+ database counts and alarm states were not consistent between two SV+ stations. This problem was found once during stress test in the large network. However, follow up tests could not reproduce similar problems.
CSCdj01109 SV+ statsparser core dumped when reading Unix password file (/etc/passwd). This problem has been reported to Sun Microsystems for investigation. This problem was found once in SIT.
CSCdj21534 The CMGUI takes a long time (about 25 minutes) to show a large number of connections (about 7000 connections) in the connection list.
CSCdj21366 Sometimes SV+ port proxy core dumped on handling a nonexistent IPX X.21 backyard.
CSCdj17225 There is a problem of displaying correct Line trap information (501). The information in slot, idstring, status, severity fields are incorrect.
CSCdj17240 There is a problem of displaying correct Port alarm information (503). The information in status and severity fields are incorrect.
CSCdj17251 There is a problem of displaying correct Trunk trap information (502). The information in status and severity fields are incorrect.
CSCdj15683 The fc_state field is not correct in the SV+ database.
CSCdj15391 The line information is missing from EMGUI for those cards support physical port scheme.
CSCdj15564 Sometimes the remote per_util of a connection is stored as 0 in the user_connection table when it should be non zero.
CSCdj19368 There is problem of displaying correct status field information for 20k series traps.
CSCdj19371 There is problem of displaying correct status and severity fields information for 25k series traps.
CSCdj00196 The user is not able to change the frame relay signalling from Annex DNNI to no signalling through EMGUI.
CSCdj11457 The rate up (RIF) parameter of a ABR foresight connection is not calculated correctly.
CSCdj15678 The nwip_on option for savecnf command does not work with 8.4.01 IPX feeders.
CSCdj20689 Sometimes databroker restarted without sending a trap to the user.
CSCdj19360 Sometimes there is a problem of showing correct PVC status in CMGUI and EMGUI/alarm view. The CMGUI failed to show an A-bit problem.
CSCdj25970 The SNMP object svFrPortSpeed in 8.4 is not matching with 8.1 for set/get results. One uses units of kbps, the other uses 100 bps.
CSCdj19575 The trapCardType for BXM-12T3 is not supported in SV+MIB and schema.
CSCdj20902 Sometimes CMGUI does not show connections of a failed IPX port. (
CSCdj22291 Sometimes incomplete connection not showing on CMGUI. This problem is intermittent.
CSCdj08401 The SV+ Service MIB should be enhanced to support following ATM parameters: CLPHighThresh, CLPLowThresh, EFCIThresh, IBS and VCQ size.
CSCdj29021 Sometime the number of user connections between two SV+ stations managing the same network do not match. This problem observed on a 8.2.50 based network only.
CSCdj33564 Sometime the connection states for AXIS connections are showing up as "OK/Abit failed" when they are actually "FAILED/Abit failed". The line on the axis shelf is in alarm state.
The 'telnet' command in AIX 4.x(x>= 1) has the following problem. If it is used to logon to any of the StrataView nodes (BPX/IPX/IGX), the login user name and password are not taken properly and the login always fails.
The workaround for this is to set the 'telnet' mode to character mode. For this enter the telnet escape character (usually combination of Control key and ']' - left square bracket -keys), which is shown on the screen as soon as the telnet command is given at 'Enter User ID:' prompt.
telnet > mode character <ENTER> <ENTER>
NetView-Network Topology-Objects can be placed out of the screen. But, no way to get them back in the screen. Work-around: Turn the Auto Layout "ON" on all the submaps. This will re-layout the map using NetView for AIX layout algorithms and bring the out of screen objects on this screen.
NetView for AIX refresh map does not work occasionally for READ-ONLY map.
NetView for AIX displays blanks in the filter window occasionally.
ovw binary goes to loop sometimes.
While using Reports feature of StrataView Plus (using Wingz 2.5), 'Window not found' messages appear on screen. These are harmless messages (press OK for the window).
While using Wingz2.5 the Config.wkz or ConfigRep.wkz, worksheets flicker when any of the list box items are selected. This is not a problem.
Sometimes, SV+ desktop does not start giving the Bad Font error. This is a problem with MWM on AIX 4.1.4. When this happens exit the MWM and restart it again, then desktop comes up ok. If the problem is still exists perform the following steps:
Step 1 On the machine where you want the desktop to be up, do a xlsfonts and redirect the output to a file.
$ xlsfonts > xx
Step 2 Set the environment variable 'FONT_FILE' to xx.
$ setenv FONT_FILE xx.
This will take care of the font problem.
One of the problems in the field is the quick dissemination of patches and release notes to ISC support and internal distribution. To standardize on a solution for this problem, the following process is adopted for the interface between TAC and internal distribution, and Strataview Plus 3rd Level support team.
SV+ Development is actively attempting to add patches to CCO for additional references to the patches. Once this is done, one should be able to find the links to the StrataView patches at the CCO site.
http://www.cisco.com
The field software support engineers can contact The Cisco TAC support center for information on the latest patch for a given version of StrataView, or browse the directory specified above for the release notes. All patches are described in the latest version of the release notes. You may find you do not need any of the patches available for a specific release of StrataView Plus.
All patches are "Inclusive" patches. Each subsequent SV+ patch includes the previous patch. This makes patch installation a single step. You MUST have previously installed SV+ or the SV+ Service Agents BEFORE applying the patches. The patch ASSUMES this has been done.
To install a patch a user would do the following:
Step 3 Get the patch tar file on to the SV+ machine.
Step 4 If the tar file name does NOT end in "Z", the file is uncompressed. These instructions are for compressed files. If your patch is not compressed, as user 'root', use the command "compress <tarfilename>" and go to step 3.
Step 5 Stop Strataview Plus.
Step 6 As user 'root' do the following on the patch level you have decided to install:
zcat <patchfilename> | tar xvf -Step 7 5. Start SV+.
The files on the patch have already been setup for the correct execution privileges, and are ready to use.
The Serial Configuration Upload Download (SCUD) product, as the name says, supports IPX/BPX/IGX configuration save and restore functionality over a serial interface.
The current available is 2.0. This tool is used for disaster recovery and is available free of cost to Cisco SV+ users having support contract.
SV+ Development is actively attempting to add this tool to CCO. Once this is done, one should be able to find the links to the SCUD patches at the CCO site.
http://www.cisco.com
1. Supports configuration save and restore for a single node network.
2. SCUD uses serial line interface on 'Control Port' of switch.
3. Following baud rates are supported:
2400, 4800, 9600, 19200 and 38400
4. The "Node Administration" window is used for user logins.No topology map will be shown.
5. SCUD supports IPX, BPX and IGX switches.
6. SCUD can be launched by any user and does not need special privileges.
7. SCUD uses the same directory structure used by SV+ to save/restore configurations.
The SCUD software will run on any Sun workstation running SunOS 4.1.x operating system. It can also be run on Sun workstation running Solaris 2.5 or 2.6 with binary compatibility support. The minimum memory requirement is 64MB. There is no special hardware requirement.
SCUD software is available on quarter inch tape in UNIX tar format. Following procedure needs to be followed for installation.
Step 1 Login on Sun workstation.
Step 2 Change directory to where you need to install SCUD (SCUD home directory). It is advisable to install SCUD in the /usr/users/svplus directory. For this you have to move any existing SV+ installation in /usr/users/svplus to some other place before installing SCUD.
Step 3 Insert tape in the tape drive.
Step 4 Use tar command as shown below to get software loaded.
$ tar xvf /dev/<driveid> where <dirveid> indicates the tape drive identifier
e.g. rst0, rmt0 etc.
There is no install script to be run. The software is ready for use.
This version of SCUD is compatible with Switch Software release 8.1, 8.2 and 8.4 only.
SCUD software uses two configuration files. Configuration file 'cnfnodes' is used to specify the switch identification. Second file 'config.sv' is similar to one used by SV+ product and contains the serial line configurations.
'cnfnodes' file can have only one line with format shown below:
<nodename>|<switch_node_id>|<switch_net_id>|<SV+_netid>|
e.g.
nmsipx02|2|1|1|
'switch_node_id' is node id of a switch.
'switch_net_id' is network (also called as domain) is of a switch.
'SV+_netid' is SV+ network id (from config.sv file)
'config.sv' can have only one line with following fields and '|' as delimiter:
SV+_netid NO NEED TO CHANGE
networkname NO NEED TO CHANGE
serialport Specify the device file name for the serial port used
Baudrate Set serial port speed, must match speed of control port at the node
autodial Phone # to dial out including any prefix needed, 0 for not dialing
SV_Timeout NOT ALLOWED TO CHANGE
Retransmit NOT ALLOWED TO CHANGE
DL_Thresh_TO NOT ALLOWED TO CHANGE
DL_Ack_TO Set application level time-out value in seconds as appropriate
DL_Blk_Size Set transmission block size in bytes, no greater than 1024
Release Specify switch software release as appropriate
e.g.
1|Network1|/dev/ttya|19200|0|7|3|0|30|256|8.1
If SCUD is running with SunOS system, no configuration is needed for the serial port. User only need to identify which tty (/dev/ttya or /dev/ttyb) is for SCUD to use.
If SCUD is running with Solaris system, user need to run the system administration tool "admintool" to configure the serial port as "Modem - Dial-Out Only". This tool can only be run by super user (root). The serial port device name to use in the "config.sv" file should be "/dev/cua/a" for ttya and "/dev/cua/b" for ttyb.
Configure the control port of the remote node to be connected as follows:
Step 1 Run "cnftermfunc c 1" command to set control port function as VT100/StrataView.
nmsipx06 TN StrataCom IPX 8 8.1.50 Sep. 18 1997 19:16 PST
Control port Auxiliary port
1. VT100/StrataView 1. Okidata 182 Printer
2. VT1002. Okidata 18 2 Printer with LOG
3. VT100
4. Alarm Message Collector
5. External Device Window
6. Autodial Modem
Last Command: cnftermfunc c 1
Next Command:
Step 2 Run "cnfterm c 19200 n 8 1 x x y n" command, replacing the port speed parameter (19200) to match the setting in 'config.sv' file, to configure the control port to this settings:
nmsipx06 TN StrataCom IPX 8 8.1.50 Sep. 18 1997 19:29 PST
Control port Auxiliary port
Baud Rate: 19200 Baud Rate: 9600
Parity: None Parity: None
Number of Data Bits: 8 Number of Data Bits: 8
Number of Stop Bits: 1 Number of Stop Bits: 1
Output flow control: XON/XOFF Output flow control: XON/XOFF
Input flow control: XON/XOFF Input flow control: XON/XOFF
CTS flow control: Yes CTS flow control: Yes
Use DTR signal: No Use DTR signal: Yes
Last Command: cnfterm c 19200 n 8 1 x x y n
Next Command:
Modem settings we use in this recommendation is for Motorola Codex 3220+ model. If you are not using this model, use the corresponding commands for your modem to configure same settings.
1. Modem attached to the remote node:
AT&F Reset to factory default
ATS0=1 Enable auto-answer on first ring
ATL1 Modem speaker at low volume
AT*SM3 Enable automatic MNP error correction
AT*DC0 Disable data compression
AT*FL0 Disable XON/XOFF flow control
AT&S1 Sets DSR to "normal"
ATE0 Disable local character echo
ATQ1 Disable result codes (modem will appear dead)
AT&W Save current configuration settings
2. Modem attached to SCUD workstation:
AT&F Reset to factory default
ATL0 Modem speaker at minimum volume
AT*SM3 Enable automatic MNP error correction
AT*DC0 Disable data compression
AT*SC1 Enable DTE speed conversion
AT*FL0 Disable XON/XOFF flow control
AT&C1 DCD controlled by modem
AT&D2 Modem disconnects when SCUD toggles DTR
AT&W Save current configuration settings
SCUD allows user to save and restore configuration from/to IPX/BPX/IGX switches. The configuration saved using StrataView Plus product is stored under /usr/users/svplus directory using <saveid>_Cfgdir as directory name. When user needs to restore the saved configuration he has to copy this directory under SCUD home directory.
e.g.
If SCUD is installed under /usr/SCUD directory and the current saved configuration has saveid of 'SV72' then user will copy the 'SV72_Cfgdir' directory from /usr/users/svplus/ (or from other directory where files are manually copied) to /usr/SCUD directory.
Step 1 Change the 'cnfnodes' and 'config.sv' files to the required configurations.
Step 2 Change directory to where SCUD is installed.
Step 3 Set DISPLAY environment variable to your workstation display.
e.g. B shell --> $ set DISPLAY :0.0
$ export DISPLAY (for local display)
--> $ set DISPLAY mach1:0.0
$ export DISPLAY (for remote machine name mach1)
C shell --> % setenv DISPLAY :0.0 (for local display)
--> % setenv DISPLAY mach1:0.0 (for remote machine name mach1)
Make sure the SCUD configuration files, the remote node's control port and the modems on both sides are configured properly before launching SCUD.
Follow these steps to launch or stop SCUD:
Step 1 Type 'SCUD' on command line and hit <RETURN>
Step 2 Select option 1 to launch SCUD or select 2 to stop SCUD.
When SCUD is launched user will see "Node Administration" window on screen. User can logon to switch and use 'loadcnf' command to restore the configuration. The configuration to be restored must have already been copied to the SCUD home directory.
There are two ways to make the modem connection:
1. Use SCUD to dial out
This is enabled by putting the phone number in the "config.sv" file. The phone number can be prefixed by 'P' or 'T' for pulse or tone dialing. Comma, ',' is also allowed in this field for additional pause time. When SCUD starts, it will dial out from the modem and wait for it to connect before the actual applications are started. Messages are displayed at the start-up window to show the progression.
If SCUD fails to make the connection, it will retry indefinitely. If retries continue to fail, user should correct the failing condition and restart SCUD.
After the connection is established, the "Node Administration" window will appear. However, it may take a couple minutes before the node's login prompt is displayed in the "Node Administration" window. This is because the node may send a lot of data out once the connection is established and SCUD has to filter them out. At this time, the "RD" light on the modem is almost solid on. Wait until this "RD" light is off, you should be able to get the node's login prompt by hitting <RETURN> on the "Node Administration" window.
2. Use other communication tools, e.g. tip
In some cases, user cannot establish the modem connection by simply dialing a phone number. For example, if the remote end modem connects to a terminal server, some commands have to be issued after the modems are connected to route the connection to the port that the remote node is on. SCUD is capable of establishing this kind of connection. Hence, user has to establish the connection manually before launching SCUD.
The modem should be setup in a way that it would not drop the line even when DTR is dropped. After user has establish the connection using tools like tip, the remote node will start sending the command line interface screen data to user's screen. These data include VT100 terminal escape sequence that looks like garbage. User should wait until these are cleared and the node's login prompt appears, then exit the tip session. Make sure the line is still up by checking the "CD" light on the modem.
Before launching SCUD, verify that in SCUD's configuration file "config.sv", the autodial (phone number) field is set to 0. If this field is set to any valid phone number, SCUD will drop the line and redial that number. After SCUD is launched with the no dial out setting, the "Node Administration" window will appear right away and the node's login prompt will show up in seconds' time.
If network id in 'config.sv' does not match with one from 'cnfnodes' SCUD does not detect it.
SCUD may not be launched if SV+ software is running on the same workstation.
The protocol between SCUD and the remote node during a configuration save or restore session enforced a simple handshaking protocol that the sending side after sending a data packet, will wait for an acknowledgment (ACK) from the remote side before sending the next data packet. An application level time-out is imposed. When time-out on waiting the ACK, the sending side will send an ABORT message to the remote end and the operation is aborted completely. At the application layer, there is no retry capability. However, at the link layer, each packet will retransmit 3 times before giving up. Depending on the modem line quality, it could be so worse that the session keep aborting and never get completed.
In SCUD release 2.0, some enhancements are added to address this issue:
1. SCUD will perform retry on a configuration restore session (loadcnf). Configuration data is sent from SCUD to the remote node. When SCUD time-out on receiving the ACK, it will re-send the last data packet. By default, SCUD will try totally 3 times on the same packet before it gives up and abort the session. A "-r <num>" command line option can be given to configd in the "start_SCUD" script to specify the number of retries SCUD use.
Please note that the retry is only performed by SCUD and it works only for a configuration restore session. For configuration save, there is no retry feature at all.
2. The Baudrate (port speed), DL_Ack_TO time-out value and the DL_Blk_Size values in SCUD's configuration file "config.sv" can be tuned to optimize performance and cope with line quality. For example, if the line quality is good, port speed and block size could be set to a higher value. On the other hand, when line quality is not so good, these 2 fields should be set to a smaller value while DL_Ack_TO should be set to a larger value to give sufficient time for link layer retransmission.
One can check the quality of the serial communication between SCUD and the remote node by running "dspsv1" command at the node. This command will show any errors on the serial communication to and from the node. Time-out values at the remote node can also be configured by the "cnfdlparm" command and setting parameters #7 (Session Timeout) and #14 (Rmt Response TO).
Log files are stored in the log directory under SCUD home directory. Messages are appended to these log files continuously even when SCUD is restarted. When they grow to certain size, they are moved to *.old and new log files are used. When the new log files are full again, the *.old will be overwritten. In other words, only one backup is kept to prevent using up all disk space.
These log files are there to help debugging in case problems occur. User should saved these files when there is problem. Otherwise, there is no need to backup these files.
There are some debugging capabilities built into SCUD as highlighted here:
1. Higher levels (L3 and L4) of verbose messages for log/svmain.log can be enabled at SCUD start-up time and toggled on/off during run time. To enable these levels of verbose messages at start-up time, modify the "start_SCUD" script to include "-w" command line option for socketd as follows:
#!/bin/sh # # $RCSfile: start_SCUD,v $ $Revision: 1.1.4.1 $ # # -f option for topod and configd need to point # the same file. # If there is a port conflict then change base # 4000 to some other number. socketd -b 4000 -c config.sv -g 560x342+1+90 -w << ! topod -e topo.err -f cnfnodes downld configd -C cnfnodes
L3 and L4 verbose messages for log/svmain.log can also be toggled on/off by sending SIGUSR2 signal to svmain process. The command is: kill -USR2 <pid> where <pid> is the process id of svmain.
2. Verbose mode can also be turned on for configd process which is responsible for the configuration save and restore operation in SCUD. Modify the "start_SCUD" script to give the "-v" command line option to configd:
#!/bin/sh # # $RCSfile: start_SCUD,v $ $Revision: 1.1.4.1 $ # # -f option for topod and configd need to point # the same file. # If there is a port conflict then change base # 4000 to some other number. socketd -b 4000 -c config.sv -g 560x342+1+90 << ! topod -e topo.err -f cnfnodes downld configd -C cnfnodes -v
The output for the verbose message from configd is stored in "configd.verbose" in SCUD home directory. This file is overwritten every time SCUD is started.
1. At times, user may see the following messages:
ipc.c:598:IPC Connect Failed, Address(4001) PID(25409):: Connection refused topod: send_packet_2_IPX failed, retrying ... ipc.c:598:IPC Connect Failed, Address(4001) PID(25408):: Connection refused topod: send_packet_2_IPX retry succeeded.
This is generated by topod process when it could not communicate with another process due to the start-up time difference. This problem is fixed in SCUD 2.0 that topod will now wait for 1 second and retry until successful. Normally, it takes only one retry to succeed. As long as the "retry succeeded" message is shown, there is no problem and user does not need to restart SCUD. If the "topod: send_packet_2_IPX failed, retrying ..." message keep showing, it usually indicates a serious system problem. User may need to reboot the workstation to clear the problem.
2. If in the middle of a SCUD session, the phone line dropped or hung, user has to restart SCUD to re-establish the connection.
In the case that modem connection is made by tip or other communication tools, the re-established connection may appear to be "dead" (no prompt or any data), or showing some garbage. This is because at the remote node, it is still in StrataView mode so it would not send the VT100 screen data. User can launch SCUD as usual and SCUD would be able to communicate with the node in StrataView mode. However, if user wants to make sure the connection is working, user can send the DEL character to the remote node by pressing the "Del" key on the workstation. This will toggle the node's control port function back to VT100 mode. User would be able to see the node's login prompt.
For service and support for a product purchased from a reseller, contact the reseller. Resellers offer a wide variety of Cisco service and support programs, which are described in the section "Service and Support" in the information packet that shipped with your chassis.
For service and support for a product purchased directly from Cisco, use CCO.
CCO is Cisco Systems' primary, real-time support channel. SMARTnet customers and partners can self-register on CCO to obtain additional content and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously---a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Please use CCO to obtain general information about Cisco Systems, Cisco products, or upgrades. If CCO is not accessible, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.

![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Dec 20 14:18:06 PST 1999