cc/td/doc/product/wanbu/82/switch
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Specification

Specification

BNM-T3 Specification

Intershelf Link

T3 Line Interface Connector: BNC connector per ANSI T1.404
T3 Cable Recommended: Coax, 75 ohm, 728A or equivalent
T3 Line Signal: DSX-3 Specification per ANSI T1.102 and ATT PUB 54014
T3 Line Rate: 44.736 Mbps ± 895 bps
T3 Framing: Asynch. C-bit Parity per ANSI T1.107a
Input Jitter Tolerance: Per ATT TR 54014, Category II Equipment
Output Jitter Generation: Per ATT TR 54014, Table B1, "Equipment with DS3 Oscillator" Category
PMD Layer Alarms: LOS, OOF, AIS, RAI
PMD Layer Performance Statistics: LCV, LES,%EFS, LSES, SEFS, PCV, PES, PSES, SEFS, UAS
Trans. Convergence Protocol: PLCP per TR-TSV-000773
TC Layer Alarms: OOF, RAI
TC Layer Performance Statistics: BIP8-CV, BIP8-ES, BIP8-SES, SEFS, UAS
ATM Layer Protocol: Per CCITT I.36. Header check sum is XORed with the COSET function (0x55)
ATM Layer Counters: Number of cells received good
Number of cells received and discarded due to bad HEC
Number of cells transmitted good
Number of cells received from CellBus
Number of cells transmitted to CellBus
Diagnostics: Header of first cell received with invalid egress
translation entries
Number of cells dropped due to invalid egress
translation entries

Card General

Synchronization: Derives 8KHz shelf synchronization clock
from a variety of sources:

· internal 8 kHz clock (10 ppm)

· BNM-T3 PLCP

· external T1/E1 clock port with a clock rate of
1.544 Mbps±50 bps (T1) or 2.048 Mbps±100 bps (E1)

External OFfice clock interface: DB15 connector via LM-T3E3-D (T1 clock)
BNC connector via LM-T3E3-B (E1 clock)
Alarm interface: CO compatible alarm indicator and counter

DB15 connector

Indicators: Per Card: Active (Green), Failed (Red), Standby (Yellow)
T3 Interface: Active & Okay (Green)
Active & Local Alarm (Red)
Active & Remote Alarm (Yellow)

Minor DS-3 Statistical Alarm

Maintenance/Serviceability Features: Internal Isolation Loopbacks
External remote loopback
Hot-pluggable
Reliability: > 65000 hours MTBF
Card Size: BNM-T3: 7.25"x 16.25"
LM-T3E3-D: 7.25" x 4.5"
LM-T3E3-B: 7.25" x 4.5"
Power: -48V DC, 25W

BNM-E3 Specification

Intershelf Link

E3 Line Interface Connector: BNC connector per ANSI T1.404
E3 Cable Recommended: Coax, 75 ohm, 728A or equivalent
E3 Line Signal Per G.703
E3 Line Rate: 34.368 Mbps
E3 Framing: G.832 and G.804
Input Jitter Tolerance: Per G.703
Output Jitter Generation: Per G.703
PMD Layer Alarms: LOS, OOF, AIS, RAI
PMD Layer Performance Statistics: LCV, LES, %EFS, LSES, SEFS, PCV, PES, PSES, SEFS, UAS
Trans. Convergence Protocol: PLCP per TR-TSV-000773
TC Layer Alarms: OOF, RAI
TC Layer Performance Statistics: BIP8-CV, BIP8-ES, BIP8-SES, SEFS, UAS
ATM Layer Protocol: Per CCITT I.36; Header check sum is XORed with the COSET function (0x55)
ATM Layer Counters: Number of cells received good
Number of cells received and discarded due to bad HEC
Number of cells transmitted good
Number of cells received from CellBus
Number of cells transmitted to CellBus
Diagnostics: Header of first cell received with invalid egress translation entries
Number of cells dropped due to invalid egress translation entries
Number of unacknowledged cells transmitted to CellBus

Card General

Synchronization: Derives 8KHz shelf synchronization clock from a variety of sources:

E3 physical interface

external T1/E1 clock port with a clock rate of 1.544 Mbps±50 bps (T1) or 2.048 Mbps±100 bps (E1)

External Office clock interface: DB15 connector via LM-T3E3-D (T1 clock)
BNC connector via LM-T3E3-B (E1 clock)
Alarm interface: CO compatible alarm indicator and controls DB15 connector
Indicators:
Per Card: Active (Green), Failed (Red), Standby (Yellow)
E3 Interface: Active & Okay (Green),
Active & Local Alarm (Red),
Active & Remote Alarm (Yellow)

Minor DS-3 Statistical Alarm

Shelf Voltage: A voltage OK (Green) B voltage OK (Green)
Alarms: Major (Red), Minor (Yellow) ACO (Yellow), History (Green)
Maintenance/Serviceability Features: Internal Isolation Loopbacks

External remote loopback

Hot-pluggable

Card Size: BNM-T3: 7.25" x 16.25"

LM-T3E3-D: 7.25" x 4.5"

LM-T3E3-B: 7.25" x 4.5"

Power: -48V DC, 25W

ASC Specification

802.3 LAN Interface Connector: AUI interface via DB-15 connector control port: DB-25 RS232 connector; Asynch interface, 99200 baud, 1 start, 1 stop, No Parity
Trouble shooting interface: Maintenance port: DB-25 RS232 connector; Asynch interface, 9600 baud, 1 start, 1 stop, No Parity
Indicators: Per Card: Active (Green), Failed (Red), Standby (Yellow)

LAN activity flashing green

Maintenance/ Serviceability Features: RS232 maintenance/debug port

Internal Isolation Loopbacks

Hot-pluggable

Reliability: > 65000 hours MTBF
Card Size: ASC: 7.25" x 16.25"

LM_ASC: 7.0" x 4.5"

Power: -48V DC, 25W

FRSM-4T1 Specification

Service Interface

Line Interface connector: DB15--when used with LM-DB15-4T1 line module
Line Rate: 1.544 Mbps ± 50 bps
Line Framing: ESF per ATT TR 54016
Synchronization: Transmitter may be either loop-timed to Receiver, or synchronized to shelf, (called normal mode)
Input Jitter Tolerance: Per ATT TR 62411
Output Jitter Generation: Per ATT TR 62411 using normal mode synchronization
Physical Layer Alarms: LOS, OOF, AIS, RAI
Number of Frame Relay Ports: 1-Single frame relay stream occupying n consecutive time slots
Frame Relay Interface Rates: Either 56 Kbps or n*64 Kbps; n as defined above
Frame Relay Interface: Per ANSI T1.618, 2-octet header
Frame Relay Performance Counters (per Port; n x DS0): Receive frames discarded due to Aborts
Receive frames discarded due to illegal header (EA bit)(s)
Receive frames discarded due to CRC errors (s)
Receive frames discarded due to alignment errors (s)
Receive frames discarded due to unknown DLCI (s)
Receive frames discarded due to illegal frame length (s)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (s)
Receive bytes (s)
Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (s)
Transmit bytes discarded due to egress Q-depth exceeded (s)
Transmit frames discarded due to egress DE threshold
exceeded Transmit frames (s)
Transmit bytes(s)
Transmit Frames with FECN set (s)
Transmit Frames with BECN set (s)
LMI receive status inquiry request count (s)
LMI transmit status inquiry request count
LMI invalid receive status count (s)
LMI signaling protocol (keep alive time-out count) (s)
LMI sequence number error count (s)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (s)
Transmit bytes during LMI alarm (s)
LMI update status transmit count (in response
to configuration changes)
Diagnostics (per port): Last unknown DLCI received

System Interface

ATM Layer: Per CCITT I.361 and ATM UNI v3.1
AAL Layer: AAL5 per Draft CCITT I.363.
FR-Cell Interworking: Per Draft CCITT I.555 and I.36x.1, as summarized in Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FRF.5.

Virtual Circuits

Channels (Endpoints): 256 per card--may be allocated across any of the frame relay interfaces
Counters:
Service Counters: Number of frames received (s)
Number of bytes received (s)
Number of frames received with DE already set (s)
Number of bytes received with DE already set (s)
Number of frames received with unknown DLCI
Number of frames received but discarded (s)
Number of received bytes discarded (s)
Number of received bytes discarded due to exceeded Q-depth (s)
Number of frames received and discarded due to: intershelf alarm
exceeded DE threshold (s)
exceeded Q depth (s)
Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (s)
Number of bytes transmitted (s)
Number of frames transmitted with DE set (s)
Number of frames discarded due to reassembly errors (s)
Number of frames transmitted during LMI logical port alarm(s)
Number of frames transmitted with FECN set (s)
Number of frames transmitted with BECN set (s)
Number of transmit frames discarded (s)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (s)
egress Q depth exceeded (s)
egress DE threshold exceeded source abort
physical link failure (T1)
ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (s)
Number of OAM FERF cells transmitted (s)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (s)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (s)
Number of OAM FERF cells received (s)
Number of BCM cells received
Number of OAM end-end loopback cells received (s)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (s)
Statistics: All of the above counters followed by an (s) can be configured as statistics.
Diagnostics: Last unknown LCN received Cells with unknown LCN count

Card General

Indicators:
Per Card: Active (Green), Standby (Yellow), Fail (Red)
Lines (one per): Active & Okay (Green)
Active & Local Alarm (Red)
Active & Remote Alarm (Yellow)
Maintenance/Serviceability Features: Internal Problem Isolation Loopbacks Hot-pluggable
Reliability: > 65000 hours MTBF
Card Size: FRSM-4T1: 7.25" x 16.25"
LM-DB15-4T1: 7.0" x 4.5"
Power: -48V DC, 30W (4 T1s)

FRSM-4E1 Specification

Service Interface

Line Interface connector: DB15--when used with LM-DB15-4E1 line module

BNC--when used with LM-BNC-4E1 line module

Line Rate: 2.048 Mbps ± 100 b
Synchronization: Transmitter may be either loop-timed to Receiver, or synchronized to shelf, (called normal mode)
Input Jitter Tolerance: Per G.703
Output Jitter Generation: Per G.703
Physical Layer Alarms: LOS, OOF, AIS, RAI
Number of Frame Interfaces: 1 to 31 occupying n where 1 < n < 31. Sum of all < 31 for CCS 1-30 for CAS
Frame Relay Interface Rates: Either 56 Kbps or n*64 Kbps; n as defined above
Frame Relay Interface: Per ANSI T1.618, 2-octet header
Frame Relay Performance Counters (per Port; n x DS0): Receive frames discarded due to Aborts
Receive frames discarded due to illegal header (EA bit)(s)
Receive frames discarded due to CRC errors (s)
Receive frames discarded due to alignment errors (s)
Receive frames discarded due to unknown DLCI (s)
Receive frames discarded due to illegal frame length (s)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (s)
Receive bytes (s)
Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (s)
Transmit bytes discarded due to egress Q-depth exceeded (s)
Transmit frames discarded due to egress DE threshold exceeded Transmit frames (s)
Transmit bytes(s)
Transmit Frames with FECN set (s)
Transmit Frames with BECN set (s)
LMI receive status inquiry request count (s)
LMI transmit status inquiry request count
LMI invalid receive status count (s)
LMI signaling protocol (keep alive time-out count) (s)
LMI sequence number error count (s)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (s)
Transmit bytes during LMI alarm (s)
LMI update status transmit count (in response to configuration changes)
Diagnostics (per port): Last unknown DLCI received

System Interface

ATM Layer: Per CCITT I.361 and ATM UNI v3.1
AAL Layer: AAL5 per Draft CCITT I.363
FR-Cell Interworking: Per Draft CCITT I.555 and I.36x.1, as summarized in "Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FERF.5"

Virtual Circuits

Channels (Endpoints): 256 per card--may be allocated across any of the frame relay interfaces
Counters: Service Counters: Number of frames received (s)
Number of bytes received (s)
Number of frames received with DE already set (s)
Number of bytes received with DE already set (s)
Number of frames received with unknown DLCI
Number of frames received but discarded (s)
Number of received bytes discarded (s)
Number of received bytes discarded due to exceeded Q-Depth (s)
Number of frames received and discarded due to: intershelf alarm
exceeded DE threshold (s)
exceeded Q depth (s)
Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (s)
Number of bytes transmitted (s)
Number of frames transmitted with DE set (s)
Number of frames discarded due to reassembly errors (s)
Number of frames transmitted during LMI logical port alarm(s)
Number of frames transmitted with FECN set (s)
Number of frames transmitted with BECN set (s)
Number of transmit frames discarded (s)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (s)
egress Q depth exceeded (s)
egress DE threshold exceeded source abort physical link failure (T1)
ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (s)
Number of OAM FERF cells transmitted (s)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (s)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (s)
Number of OAM FERF cells received (s)
Number of BCM cells received
Number of OAM end-end loopback cells received (s)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (s)
Statistics: All of the above counters followed by an (s) can be configured as statistics.
Diagnostics: 8Last unknown LCN received
Cells with unknown LCN count
Card General
Indicators: Per Card: Active (Green), Standby (Yellow), Fail (Red)
Lines (one per): Active & Okay (Green)
Active & Local Alarm (Red)
Active & Remote Alarm (Yellow)
Maintenance/Serviceability Features: Internal Problem Isolation Loopbacks
Hot-pluggable
Card Size: FRSM-4E1: 7.25" x 16.25"
LM-DB15-4E1: 7.0" x 4.5"
LM-BNC-4E1: 7.0" x 4.5"
Power: -48V DC, 30W (4 E1s)
Ingress 8000 cell buffer shared between virtual channels/paths
Standard Usage Parameter Control (UPC)
Selective Cell Discard
Virtual Circuit Queuing
EFCI setting per VC
Egress 8000 cell storage capacity shared between four ports
Up to 12 user selectable Egress Queues per port
Selective Cell Discard
EFCI setting per Queue

AUSM Specification

Service Interface (T1)

Line Interface Connector Miniature 15 pin female DB-15 (100 W)--(Use LM-DB15-4T1)
Line Rate: 1.544 Mbps ± 50 bps (T1)
Synchronization: Transmitter may be either loop-timed or Receiver, or synchronized to shelf (called normal mode)
Line Code: Bipolar 8 Zero Substitution (B8ZS) as specified in ANSI T1.408 (T1)
Line Framing: Extended Superframe Format (ESF 24 frame multiframe) as ANSI T1.408
ESF Maintenance Functions: Bit-oriented alarm and loopback messages of ESF Data Link as per ANSI T1.408
Input Jitter Tolerance: Per ATT TR 62411
Output Jitter Tolerance: Per ATT TR 62411 using normal mode synchronization
Physical Layer Alarms: LOS, OOF, AIS, RAI
Physical Layer Performance Stats: LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS

Service Interface (E1)

Line Interface Connector Miniature 15 pin female DB-15 (120 W)--(Use LM-DB15-4E1), BNC (120 W)--(Use LM-BNC-4E1)
Line Rate: 2.048 Mbps ± 50 bps (E1)
Synchronization: Transmitter may be either loop-timed or Receiver, or synchronized to shelf (called normal mode)
Line Code: HDB3 (E1)
Line Framing: 16 frame Multiframe as in G.704
Input Jitter Tolerance: As specified in ITU G.823 for 2.048 Mbit/s
Output Jitter Tolerance: As specified in ITU G.823 for 2.048 Mbit/s
Physical Layer Alarms: LOS, OOF, AIS, RAI
Physical Layer Performance Stats: LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS

ATM Interface:

ATM UNI v3.1, ITU-T G.804, per CCITT I.361
Channel Configuration: 256 per card
May be allocated across any of the T1 (E1) ports
VPI/VCI: VPI: 0-255
VCI: 0-4096
Traffic Classes: CBR, VBR, VBR+
UPC Parameters: PCR, SCR (VBR), CCDV (CBR)
Congestion Control Support: ForeSight (towards Network for VBR+)
ForeSight Parameters: MIR, PIR, Rate Up, Rate Down, QIR, QIR Timeout, IBS

Virtual Circuits

Counters:
Per Port: Number of cells received from the interface.
Number or cells received with unknown VPI/VCI.
Last known VPI/VCI received from the port.
Number of cells discarded due to error in Cell Header.
Number of cells received with non zero GRC field.
Number of cells transmitted to the interface.
Number of cells transmitted for which EFCI was set.
Number of egress cells discarded due to service interface physical alarm.
Endpoint (channel):
Ingress: Number of cells received from port.
Number of cells received from the port with CLP = 1.
Number of cells received from the port with EFCI = 1.
Number of cells from the port discarded due to queue exceeded QDepth.
Number of cells (with CLP) set) discarded due to queue exceeded CLP threshold.
Number of cells from the port for which CLP was set due to UPC violations.
ATMizer channel counters:
Ingress: Number of cells transmitted to CellBus.
Number of cells to CellBus for which EFCI was set.
Number of cells to CellBus discarded due to shelf alarm.
Egress: Number of cells received from the CellBus
Number of cells discarded due to queue exceeded QDepth (per Egress Q)
Number of cells discarded due to queue exceeded CLP threshold
(per Egress Q)
Number of cells received with CLP = 1
Other Counters: .
Ingress: Number of OAM cells discarded.
Number of AIS cells received from the port.
Number of RDI (FERF) cells received from the port.
Number SegmentLpBk cells received from the port.
Number of SegmentLpBk cells transmitted to CellBus.
Egress: Number of OAM cells discarded.
Number of AIS cells transmitted to the port.
Number of SegmentLpBk cells transmitted to the port.
Number of SegmentLpBk cells received from the port.
Diagnostic Stats: Peak Queue Depth (Ingress: per channel).

Card General:

Indicators:
Per Card: Active (green), Standby (yellow), Fail (red)
Per Line: One per line: Active & OK (green)
Active and Local Alarm (red)
Active and Remote Alarm (yellow)
Maintenance/Serviceability: Facility loopback via Loop up/down per ANSI T1.408 & AT&T
TR 62411 (T1), CCITT G.7xx (E1)
Facility Loopback via Management Console
Internal Problem Isolation Loopbacks
Hot pluggable
Card Size: 7.25" x 15"
Power: -48VDC, 30 W
Safety: EN 60950 2nd edition (including EN 41003) UL 1950 2nd edition
Compliance: T1: Accunet 62411 E1: G.703, G.823
ESD: IEC 1000-4-2

CESM-4T1/E1 Specification


Note The CESM-4T1/E1 specification is the same as the FRSM-4T1/4E1 specification except as shown below.

Service Interface (T1/E1)

Synchronization: Transmitter is synchronized to the shelf (Stratum traceable)
Line Framing: None
Channel Configuration:
Number of CBR Interfaces: 4
Cell Delay Variation (CDV): Configurable by setting reassembly buffer depth to a maximum of 250 msec. CDV = 1/2 buffer depth

Virtual Circuits

Channels (Endpoints):

One per physical por
Counters: MIB Name
AAL1:
Number of lost SAR-PDUs
Number of buffer overflow events
Number of buffer underflow events
Number of SAR-PDU's with header error
Number of SAR-PDU's received out of sequence
Number of cells played out to T1/E1 port
Number of cell generated from T1/E1 port
Number of bytes discarded due to shelf alarm, from port
Number of all 1's cells inserted during buffer underflow
Number of bytes discarded due to egress overflow
cesLostCells
cesBufOverflows
cesBufUnderflows
cesHdrErrs
cesCellSeqMismatchCnt
cesReassCells
cesGenCells
cesIngrDiscardedBytes

cesUflowInsCells

cesOflowDropBytes
Diagnostic: Egress buffer depth (per port)
Alarms: MIB Name
T1/E1 Port: Red, Loss of Signal (LOS)

Blue, Alarm Indication Signal (AIS)

LineAlarmState--bit 5 set

LineAlarmState--bit 2, set and cesChanState = 3

Line Code Violation (LVC) LineStatisticalAlarmState
SAR Port:
Transmit state: SendingAIS

Sending FERF

cesXmtATMState = 3

cesXmtATMState = 4

Receiving state:
Receiving AIS

Receiving FERF

Cell Loss

cesRcvATMstate = 3

cesRcvATMstate = 4

cesCellLossStatus = 2


Note All service specific alarms, except RED, will be passed through transparently.

Loss of Signal (RED) at CBR interface will result in All Ones cells being transmitted.

Brief periods of cell loss "Starvation" will result in insertion of 47 octects of one's.

Extended periods of cell loss will result in All Ones (Unframed AIS) being generated.

During periods of Cell Bus configuration SAR-PDUs will be discarded.IMATM Specification

IMATM Specification

Physical Interface (T3.T1) RJ48-T3T1-LM:

T1 Line Interface connector: Miniature RJ-48C, 100 ohms balanced
T3 Line Interface connector: BNC, 75 ohms unbalanced
Physical Interface (E3.E1) RJ48-E3E1-LM:
E1 Line Interface connector: Miniature RJ-48C, 100 ohms balanced
E3 Line Interface connector: BNC, 75 ohms unbalanced
Physical Interface (E3.E1B) SMB-E3E1-LM:
E1 Line Interface connector: Miniature SMB, 75 ohms unbalanced
E3 Line Interface connector: Miniature SMB, 75 ohms unbalanced

Physical Layer Interface T1:

Line rate: 1.544Mbps +/- 50 bps.
IMATM Synchronization: Digital PLL to synchronize all transmitters to a choice of one of the following: the T3 line, any of the T1 lines, the MGX 8220 shelf 8KHz clock.
Line Code: Bipolar 8 zero substitution (B8ZS) as specified in ANSI T1.408.
Line Framing: Extended Superframe Format (ESF 24 frame multifrm) as in
ANSI T1.408.
Input Jitter Tolerance: Per ATT TR 62411.
Output Jitter Tolerance: Per ATT TR 62411 using normal mode synchronization.
Physical Layer Alarms: LOS, OOF, AIS, RDI.
Physical Layer Performance Parms: LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS.

Physical Layer Interface E1:

Line rate: 2.048Mbps +/- 50 bps
IMATM Synchronization: Digital PLL to synchronize all transmitters to a choice of one of the following: the E3 line, any of the E1 lines, the MGX 8220 shelf 8KHz clock.
Line Code: HDB3 (E1).
Line Framing: 16 frame Multiframe as in G.704.
ESF Maintenance Functions: None.
Input Jitter Tolerance: As specified in ITU G.823 for 2.048 Mbits/s.
Output Jitter Tolerance: As specified in ITU G.823 for 2.048 Mbits/s.
Physical Layer Alarms: LOS, OOF, AIS, RDI.
Physical Layer Performance Parms: LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS.

Physical Layer Interface T3:

Line Rate: 44.736 Mbps ±200 ppm (T3)
Line Code: B3ZS for DS3
Framing: Physical Layer Conversion Procedure for DS3 to ANSI TA-TSY-000772 and TA-TSY-000773
Input Compliance: Per ATT 54014 and CCITT G.703

Physical Layer Interface E3:

Line Rate: 36.368 Mbps ±200 ppm (T3)
Line Code: HDB for E3
Framing: Per ITU-T Recommendation G.804 and G.832
Input Compliance: Per CCITT G.824
ATM Interface:
Cell support (type): STI cells
Congestion Control: EFCI/FFCI setting on Egress (AIM)
EFCI setup: Via programmable EFCI threshold
IMAIM Alarms: IMAIM complies with DS3 and G.832 physical layer protocols: Supports FERF, LOS, LOF, OOF, AIS, yellow and red alarms

AIM Groups and Links

Counters:
High Speed Port: DS3/E3 physical layer line alarm indication and insertion
DS3/E3 SUNI-PDh number of cells: Tx and Rx
PLL clock recovery status
AIM Group: Number of cells received from AIM interface
Number of cell discarded due to error in Cell Header
Number of cells from AIM interface discarded due to Queue Full on both Ingress and Egress directions
Number of ACP cells received
Number of ACP cells received with errors
Number of LCP cells received
Number of LCP cells received with errors
Number of cells served from Egress queue to AIM interface
Number of cell transmitted by trunk interface, two types: Date and Filler + Data
Number of times a link went off the IMAIM group
ATMizer (Cellbus) counters:
Ingress: Number of cells transmitted.
Number of cells discarded due to shelf alarm
Egress: Number of cells received
Number of cells discarded due to queue depth exceeded QDepth

Card General

Indicators:
Per Card: Active (Green), Standby (Yellow), Fail (Red)
Lines (one per): Active and OK (Green)
Active and Local Alarm (Red)
Active and Remote Alarm (Yellow)
Maintenance/Serviceability Features: Internal Problem Isolation Loopbacks
Hot-pluggable
Card Size: IMATM front card: 7.25" x 16.25"
RJ48-T3T1-LM: 7.0" x 4.5"
RJ48-E3E1-LM: 7.0" x 4.5"
SMB-E3E1-LM: 7.0" x 4.5"
Power: -48V DC

hometocprevnextglossaryfeedbacksearchhelp