Caution Please note that the automated installation CD must NOT be used for upgrades or reinstalls, but for new installations only. If the Cisco uOne software is reinstalled over existing software, it will overwrite existing files including any configuration files and subscriber messages. To determine whether you currently have Cisco uOne installed on your system, please check Add/Remove Programs in the Windows Control Panel folder of your system. |
The Automated Installer consists of a set of two Cisco Media Convergence Server (MCS) Quickbuilder CDs which sets up the operating system for a new MCS-7835 machine and installs uOne and its supporting servers. The first CD configures the new system and installs Windows NT 4.0. The second CD-ROM performs the automated installation of the uOne components.
The Automated Installer assists in the installation and configuration of uOne software. Before beginning the installation process, the Automated Installer performs some checks to ensure that the parameters for a successful installation are in place.
If you have uOne currently installed, a warning message displays advising you that the CD is for new installations only. Proceeding with a reinstallation may overwrite any existing data. For migrating your existing uOne system to this Corporate version, please see the "Migrating uOne" chapter of this guide. If you need to reinstall the software, please refer to the "Removing and Reinstalling Software" chapter of this guide.
The Automated Installer controls the Windows NT Administrator password during installation of the operating system and uOne. At the end of the installation of uOne, you are prompted to enter an Administrative password for the NT system.
The domain name is an important element of your system, and must adhere to certain parameters in order for the installation to complete successfully. The domain name must adhere to the following restrictions.
1. It must be 32 characters or less. The Automated Installer does not allow a domain name longer than 32 characters.
2. It must be a top-level domain name (that is, machine.com rather than cisco.machine.com). If it is not, the Automated Installer displays an error message reminding you that only a top-level domain name may be used.
3. The domain name cannot include hyphens, underscores, or any other special character, such as:
![]() |
Caution Do not change your domain name after installation. Be sure that your domain name meets the installation parameters BEFORE you begin the installation process. If you decide to change your domain name after installation, you must remove and reinstall the software from your system. To remove and reinstall software, please refer to the "Removing and Reinstalling Software" chapter of this guide. |
Follow these procedures to set up a new system for the uOne messaging software:
To set up the operating system for a new Cisco MCS-7835 system, you should use Table 1-1 to gather the necessary information for the installation.
| Parameter | Example | Your Value |
|---|---|---|
Product Key | ORAG FJGH IJJK RXQR |
|
User Name | Technology |
|
Organization | Cisco Systems |
|
ComputerName | uOnePC |
|
Workgroup Name | Domain1 |
|
DNS Domain | cisco.com |
|
IP Address for uOne system | 198.166.34.40 |
|
Subnet Mask | 255.255.255.0 |
|
Default Gateway | 198.166.34.30 |
|
DNS Server IP Address, if your system is using DNS server |
|
|
Follow these instructions to install the NT operating system.
![]() |
Note After turning on the system, if you do not automatically receive the Cisco Avvid Welcome screen after the system processes the array configuration, press F1 at the configuration information in the DOS window to continue the installation CD. |
Step 2 At the Welcome dialog for the MCS setup, press Next.
Step 3 After the installation process evaluates the system, the Type of Installation dialog appears. For a new installation or server replacement, select New Installation or Server Replacement. Press Next.
Step 4 Press Next at the Configuration Process dialog. The system restarts and proceeds to check the hardware.
Step 5 Press Next at the dialog warning that the system will be cleaned of all information and reconfigured. The installation process continues performing hardware configuration and installing files. The system automatically restarts. Do not remove the installation CD during this restart.
Step 6 Enter your Product Key number at the Product Key dialog. This product key is an identification number given to you by your Account Representative for your software license. Press Next.
Step 7 Read the Software License Agreements and if you agree to its terms press the I Agree button. The installation process will not proceed unless you agree to the terms of the License Agreement.
Step 8 Press Next at the Server Replacement Option dialog.
![]() |
Note The checkbox should remain blank unless you are recovering a system from backup and have restoration information located on tape or a network area. |
Step 9 Press Next to complete the installation process, which should take approximately 5 minutes.
Step 10 After installation is complete, you see a DOS message stating MCS SERVER BUILD IS COMPLETE. EJECT THE CD AND PRESS ANY KEY TO REBOOT. Remove the operating system installation CD and press Enter to restart your system.
After restarting the new MCS-7835 system, you use the Cisco MCS Configuration Wizard to set up the system for the network. To set up your system, follow these steps.
Step 2 Enter the User Name and Organization for this system. Press Next.
Step 3 Enter the ComputerName, Workgroup name, and DNS Domain information for this system in each of the fields. Press Next to continue.
Step 4 Select the appropriate Time Zone. Press Next.
Step 5 Select the correct Date and Time. Press Next.
Step 6 Enter the IP address, Subnet mask, and Default Gateway information to be used by the MCS-7835. Press Next.
Step 7 Enter the IP address for the DNS server, if a DNS server will be used. Press Next.
Step 8 Press Next for the MCS Configuration Wizard to set up your Windows NT system and automatically restart.
After multiple automatic reboots, you are logged on to the system as administrator by default, and a dialog reflects the additional software that your Product Key allows you to install. You will now proceed to install uOne using the instructions in the "Installing uOne" section of this guide.
Please check that you have completed the following prior to installing uOne:
For a new installation of uOne software on your system, follow these steps.
Step 2 Press Next at the Welcome screen for the uOne Installation Wizard.
Step 3 Select CallManager 2.4 (MS Access) at the CallManager Database Location dialog.
Step 4 Enter the CallManager Host Name for your CallManager system, without the domain name (for example, CallMgrHost).
![]() |
Note If your network is running Domain Name Service (DNS), you can enter the host name for your CallManager system or the IP address for that system. If you are not running DNS on your network, you need to use the IP address for your CallManager Host Name, or edit the C:\WinNT\System32\Drivers\etc\hosts file to add the CallManager IP address and name. |
Step 5 Press Next to proceed with the installation of uOne Messaging Platform.
![]() |
Caution If the host information is invalid, you receive a message that this information must be entered correctly. Pressing Yes to continue the installation without the valid information may cause difficulties when reconfiguring CallManager settings after installation. To return to the dialog and edit the host information, press No. |
The installation process takes approximately 20 minutes to complete and includes Netscape Communicator, Netscape Directory Server, Netscape Messaging Server, Apache Server, and Diskeeper.
The installation of the uOne Messaging Platform continues with the following steps.
Step 2 A confirmation message displays and allows the option to configure additional backup targets. Press OK.
Step 3 The Cisco MCS Backup Utility Configuration dialog allows you to configure CallManager targets, uOne targets, backup destination, and scheduling. It is not necessary to complete the backup information at the time of installation. Press OK to accept the default information.
Step 4 Select Yes to confirm that you wish to save the backup settings.
Step 5 You are prompted to enter a new password for the Administrator account, and confirm the password. After entering this password, press OK.
Step 6 At the prompt confirming change of password, press OK.
Step 7 When installation is complete, eject the CD. Then press Yes to the dialog to reboot the system.
Step 8 After the system restarts, press Ctrl+Alt+Del to log on to the system as Administrator.
Step 9 Enter your Administrator password, and press OK.
All uOne services are automatically stopped and restarted. Once the computer has restarted, you need to set the schedule for Diskeeper.
During installation of uOne components, Diskeeper 5.0 is installed on your system. Diskeeper is a utility that allows you to maintain maximum system performance, as well as providing a restoration utility.
To get the best performance from Diskeeper, it is recommended that you set Diskeeper to run once a week, and that you run Diskeeper with as few background processes as possible. To set the Diskeeper schedule, follow these steps.
Step 2 Select the Programs menu in the popup menu.
Step 3 Select Executive Software, then DiskeeperServer, then Diskeeper. The Microsoft Management Console window displays.
Step 4 Click OK to access the Diskeeper scheduling utility.
Step 5 Click on the Action menu.
Step 6 From the Action menu, select Set It and Forget It, then Disk Volume Scheduler to display the scheduler window.
Step 7 Select the disk volume C: [NTFS] [MCS7835] from the Disk Volume List.
Step 8 To set Diskeeper to run once a week:
a. Select Continuous from the Run dropdown menu.
b. Select a day of the week on which you want Diskeeper to run from the when dropdown menu.
c. Select a start time for Diskeeper to run from the between dropdown menu.
d. Select a stop time for Diskeeper to stop running from the and dropdown menu.
![]() |
Note It is recommended that you schedule Diskeeper for at least three hours to complete the defragmentation process. |
Step 9 Click the Start button. The entry is added to the scheduler window.
Step 10 Click Close.
Step 11 To exit Diskeeper, click on the X from the window title bar to close the application.
If problems occur during the automated installation (relating to system performance or installation errors) which cause you to restart the system, you need to restart the full installation process. This procedure assures accurate installation of all components.
To stop and restart the Automated Installer, follow these steps:
Step 2 Reboot the MCS system to restart the full installation process. If the system does not reboot, be sure to shutdown the system manually before continuing with the uOne installation.
Step 3 Proceed with the instructions in the section entitled Installing the Operating System, in this chapter.
After you have successfully installed the uOne software, you must configure both uOne and CallManager for successful operation. Instructions for uOne configuration are found in the "Configuring uOne" chapter of this guide. For more information on uOne configuration, see the uOne Administration and Operations, Corporate Edition 4.1 guide. Instructions for CallManager configuration are found in the "Configuring CallManager" chapter of this guide.
The uOne installation CD contains the installation software only. If you are migrating from a single-box solution to the Corporate dual-box solution, you need to perform the steps found in the "Migrating uOne" chapter of this guide to transfer your information from an existing directory server database and messaging server database to the new uOne corporate server.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Jun 12 11:28:29 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.