cc/td/doc/product/voice/ics7750
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Error Message Summary

Error Message Summary

This appendix lists system error messages and is organized as follows:

Understanding Error Messages

System error messages begin with a percent sign (%) and are structured as follows:

%FACILITY-[SUBFACILITY-]SEVERITY-MNEMONIC:message_text%

Error Message Elements

The elements of system error messages are described below.

The following is an example of a system error message:

%SPE-FMM-0-41100:Fan X failure

where SPE is the FACILITY keyword (representing the system processing engine), FMM is the SUBFACILITY keyword (representing the system software fault management module), 0 is the SEVERITY, 41100 is the MNEMONIC, and Fan X failure is the message text.


Table A-1: Representation of Variable Fields in Error Messages
Representation Type of Information

[char]

Single character

[chars]

Character string

[dec]

Decimal number

[enet]

Ethernet address (such as 0000.FEED.00C0)

[hex]

Hexidecimal number

[inet]

Internet address (such as 12.128.2.16)

[node]

Address or node name

Error Message Lists

This section lists error messages that are unique to the Cisco ICS 7750. The following types of lists are available:


Note   For a comprehensive list of error messages that are not unique to the Cisco ICS 7750, refer to the Cisco IOS Software System Error Messages publication.

Categorical List of Error Messages

The following list shows each error message that is specfic to the Cisco ICS 7750, grouped according to the following categories:

Within each category, messages are listed alphabetically.

Fan Malfunction and System Overheat Error Messages

The ambient temp [dec][char] exceeded recommended value

Card [dec] is overheated [dec][char]

Fan [dec] failure

Fan tray absent

The system is overheated [dec][char]

Power Error Messages

AC power is off, using DC

Power supply [dec] failure

UPS battery low

UPS module failure

Numerical List of Error Messages

The following list shows each Cisco ICS 7750 error message, in numerical (mnemonic) order. An explanation of the possible cause of the error and a suggested course of action are provided for each message.


Note   In actual error messages, the mnemonic (error message number) is preceded by the message severity level. For example, a UPS module failure (which has a severity level of "1" and a "40100" mnemonic) is displayed as 1-40100:UPS module failure. (See "Error Message Elements" earlier in this chapter for a full description of error message syntax.)

40100:UPS module failure

41102:The ambient temp [dec][char] exceeded recommended value

41103:Card [dec] is overheated [dec][char]

41100:Fan [dec] failure

41101:Fan tray absent

41104:The system is overheated [dec][char]

41105:AC power is off, using DC

41107:Power supply [dec] failure

41109:UPS battery low


hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Oct 2 13:41:18 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.