This document explains how to install or upgrade memory and data modules on system processing engine (SPE) 200 cards and multiservice route processor (MRP) 200 cards in the Cisco Integrated Communications System 7750, referred to from this point as the SPE 200, the MRP 200, and the Cisco ICS 7750, respectively.
Use this document in conjunction with the Cisco ICS 7750 Hardware Installation Guide and the Regulatory Compliance and Safety Information for the Cisco ICS 7750 publication.
This document contains the following sections:
This section describes the modules that you can install in an SPE 200 or an MRP 200.
The SPE 200 ships with 512 MB of RAM, provided by two dual in-line memory modules (DIMMs), as shown in Figure 3. This document provides instructions on how to remove and replace DIMMs in the SPE 200.
Table 1 provides information about the replacement DIMM for the SPE 200:
| Description | Cisco Part Number |
|---|---|
256-MB SDRAM DIMM | MEM-SPE-256D= |
The MRP 200 ships with 64 MB of on-board RAM. You can install the following types of modules in an MRP 200:
This document provides instructions on how to install, remove, and replace DIMMs and PVDMs in the MRP 200.
Table 2 provides information about the modules that you can install in the MRP 200:
| Description | Cisco Part Number |
|---|---|
16-MB SDRAM DIMM | MEM-MRP-16D= |
32-MB SDRAM DIMM | MEM-MRP-32D= |
4-channel packet voice/fax data DSP module | PVDM-4= |
8-channel packet voice/fax data DSP module | PVDM-8= |
12-channel packet voice/fax data DSP module | PVDM-12= |
16-channel packet voice/fax data DSP module | PVDM-16= |
20-channel packet voice/fax data DSP module | PVDM-20= |
Read the warnings in this section before removing or installing the SPE 200 and the MRP 200. For translations of these and other warnings that appear in Cisco ICS 7750 documentation, refer to the Regulatory Compliance and Safety Information for the Cisco ICS 7750 publication.
![]() |
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. |
![]() |
Warning This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 16A international) is used on the phase conductors (all current-carrying conductors). |
![]() |
Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use. |
![]() |
Warning Only trained and qualified personnel should be allowed to install or replace this equipment. |
![]() |
Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. |
![]() |
Warning The device is designed to work with TN power systems. |
![]() |
Warning The SPE 200 contains a lithium battery. There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. |
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled. ESD can result in complete or intermittent failures. Always follow ESD-prevention procedures when removing and replacing the SPE 200 and the MRP 200:
Ensure that the chassis is electrically connected to earth ground.
![]() |
Caution For safety, periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohms (Mohm). |
You need the following tools and equipment to remove and install SPE 200 or MRP 200 modules:
This section explains how to remove cards from the chassis. A typical Cisco ICS 7750 chassis is shown in Figure 1.

![]() |
Warning Removing cards can expose you to high-energy (high-amperage) circuits and possible ejection of molten metal, or to the shock hazard of telephony circuit voltages. Be sure to remove all rings, watches, and other jewelry from fingers, wrists, and arms before removing cards. |
![]() |
Note Depending on your system configuration, hot swapping SPE 200 cards or MRP 200 cards can adversely affect users connected to the system. For example, if Cisco CallManager is running on only one SPE 200, hot swapping that card disconnects calls to or from the PSTN and prevents the system from processing further PSTN traffic until an operational SPE 200 is properly re-inserted in the chassis. Similarly, hot swapping an MRP 200 that is in the process of routing voice or WAN traffic prevents that traffic from reaching its destination. Contact your Cisco sales representative for guidelines on installing cards and software on your system for maximum availability and redundancy. |
![]() |
Note You do not need to turn off power for this hot-swap procedure. |
Follow these steps to remove the SPE 200 or the MRP 200 (see Figure 2):
Step 2 Press the SHTDN button, and confirm that the STATUS LED on the card first blinks and then goes off.
Step 3 After the STATUS LED turns off, press the upper and lower ejector levers outward at the same time to eject the card.
Step 4 Gently pull the card from the chassis.

This section shows you how to locate the DIMM and the PVDM slots on the SPE 200 and the MRP 200.
The SPE 200 has two DIMM slots. Figure 3 shows the location of the slots.

The MRP 200 has one DIMM slot and two PVDM slots. Figure 4 shows the location of these slots.

This section explains how to remove and install SPE 200 and MRP 200 modules.
![]() |
Warning When performing the procedures in this section, wear grounding wrist straps to avoid ESD damage to the Cisco ICS 7750. Do not directly touch the backplane with your hand or any metal tool, to prevent personal injury or equipment damage. |
This section explains how to remove and install DIMMs.
DIMMs are manufactured with polarization notches to ensure proper orientation and with alignment holes to ensure proper positioning. Figure 5 shows the notches and holes on a DIMM. DIMMs are installed with the connector edge down.
![]() |
Caution To avoid damaging ESD-sensitive components, observe all ESD precautions. To avoid damaging the underlying board, do not use excessive force when you remove or replace DIMMs. |

Follow these steps to remove a DIMM from an SPE 200.
Step 2 Locate the DIMM slots on the SPE 200. See Figure 3.
![]() |
Caution Handle DIMMs by the edges only. DIMMs are ESD-sensitive components and can be damaged by mishandling. |
Step 3 Remove the DIMM by pushing the plastic release latches on each side of the DIMM slot outward. (See Figure 6.) This ejects the DIMM from its socket.
Step 4 Hold the DIMM by the edges with your thumbs and index fingers, and lift it out of the socket. Place the removed DIMM in an antistatic bag to protect it from ESD damage.
Step 5 If necessary, repeat Step 3 and Step 4 for the other DIMM.

Follow these steps to install a DIMM in an SPE 200.
![]() |
Caution Handle DIMMs by the edges only. DIMMs are ESD-sensitive components and can be damaged by mishandling. |
Step 2 Remove the DIMM from its antistatic packaging.
Step 3 Hold the DIMM with the polarization notches closer to the card edge and with the connector edge at the bottom.
![]() |
Caution It is normal to feel some resistance when installing a DIMM, but do not use excessive force on the DIMM, and do not touch the surface components. |
Step 4 Insert the DIMM perpendicular to the socket. Push the DIMM firmly into place (see Figure 7), using the minimum amount of force required. When the DIMM is properly seated, the socket guide posts fit through the alignment holes, and the locking spring clips click into place.

Step 5 Ensure that each DIMM is straight (perpendicular to the socket).
Step 6 If necessary, repeat Steps 3 through 5 for the other DIMM.
![]() |
Note When you finish installing DIMMs, if you do not intend to install components on any other cards, proceed to the "Installing Cards" section. If you intend to install DIMMs on an MRP 200, continue. If you intend to install PVDMs on an MRP 200, proceed to the "Removing and Installing PVDMs" section. |
Follow these steps to remove the DIMM from an MRP 200.
Step 2 Locate the DIMM slot on the MRP 200. See Figure 4.
![]() |
Caution Handle DIMMs by the edges only. DIMMs are ESD-sensitive components and can be damaged by mishandling. |
Step 3 Remove the DIMM by pushing the plastic release latches on each side of the DIMM slot outward. (See Figure 8.) This ejects the DIMM from its socket.
Step 4 Hold the DIMM by the edges with your thumbs and index fingers, and lift it out of the socket. Place the removed DIMM in an antistatic bag to protect it from ESD damage.

Follow these steps to install a DIMM in an MRP 200.
![]() |
Caution Handle DIMMs by the edges only. DIMMs are ESD-sensitive components and can be damaged by mishandling. |
Step 2 Remove the replacement DIMM from its antistatic packaging.
Step 3 Hold the DIMM with the polarization notches closer to the center of the card and with the connector edge at the bottom.
![]() |
Caution It is normal to feel some resistance when installing a DIMM, but do not use excessive force on the DIMM, and do not touch the surface components. |
Step 4 Insert the DIMM perpendicular to the socket. Push the DIMM firmly into place (see Figure 9), using the minimum amount of force required. When the DIMM is properly seated, the socket guide posts fit through the alignment holes, and the locking spring clips click into place.

Step 5 Ensure that the DIMM is straight (perpendicular to the socket).
![]() |
Note When you finish installing DIMMs, if you do not intend to install PVDMs on this card and do not intend to install components on any other cards, proceed to the "Installing Cards" section. If you intend to install PVDMs on an MRP 200, continue with the "Removing and Installing PVDMs" section. If you intend to install DIMMs on an SPE 200, see the previous section. |
This section explains how to remove and install PVDMs on the MRP 200.
PVDMs are manufactured with a polarization notch to ensure proper orientation and with alignment holes to ensure proper positioning. Figure 10 shows the notch and the holes on a PVDM. PVDMs are installed connector-edge down.
![]() |
Caution To avoid damaging ESD-sensitive components, observe all ESD precautions. To avoid damaging the MRP 200, avoid using excessive force when you remove or replace PVDMs. |

Follow these steps to remove PVDMs:
Step 2 Locate the PVDM slots on the MRP 200. See Figure 4.
![]() |
Caution Handle PVDMs by the card edges only. PVDMs are ESD-sensitive components and can be damaged by mishandling. |
Step 3 Remove one PVDM at a time, beginning with the PVDM closest to the rear of the card. To lift the PVDM out of its socket, pull the locking spring clips on both sides outward, and tilt the PVDM toward the rear of the card, free of the clips. (See Figure 11.)

Step 4 Hold the PVDM by the edges with your thumbs and index fingers, and lift it out of the socket. Place the removed PVDM in an antistatic bag to protect it from ESD damage.
Step 5 Repeat Step 2 and Step 3 for the second PVDM.
Follow these steps to install PVDMs:
Step 2 Locate the PVDM slots on the MRP 200. See Figure 4.
![]() |
Caution Handle PVDMs by the card edges only. PVDMs are ESD-sensitive components and can be damaged by mishandling. |
Step 3 Hold the PVDM with the polarization notch closer to the card edge and the connector edge at the bottom. (See Figure 11.)
Step 4 Beginning with the slot closer to the front of the card, insert the PVDM into the connector slot at an angle, tilted toward the rear of the card. Align or move the PVDM into a vertical position (see Figure 12), using the minimum amount of force required. When the PVDM is properly seated, the socket guide posts fit through the alignment holes, and the connector springs click into place.
Step 5 Ensure that the PVDM is straight and that the alignment holes (as shown in Figure 11) line up with the plastic guides on the socket.

![]() |
Caution It is normal to feel some resistance, but do not use excessive force on the PVDM, and do not touch the surface components. |
Step 6 Repeat Step 2 through Step 4 for the second PVDM.
This section explains how to install cards into the Cisco ICS 7750 chassis.
![]() |
Caution When installing a card into the chassis, be sure to apply equal amounts of pressure to the top and bottom of the card. You can damage the card and the chassis backplane if you apply too much pressure to either the bottom or the top of the card. |
Follow these steps to install a card:

Step 2 With the top and bottom edges of the card in the card guides, gently slide the card into the chassis until you feel resistance. Because there are grounding clips near the front and rear of the card guides, you might need to increase the amount of force to get the card past the grounding clips, particularly if this is the first time a card has been inserted in this slot. If you encounter extreme resistance, pull the card out slightly, and push it in again.
Step 3 Press the upper and lower ejection levers inward at the same time until they lock into their slots. This step firmly seats the card into the chassis.
Step 4 Repeat Steps 1 through 3 to install additional cards.
Step 5 When all cards have been installed, completely tighten the card captive screws on the top and bottom of the panel.
To verify that the cards you have just installed are operating correctly, verify that the LEDs on those cards are functioning as described in Table 3.
![]() |
Note The ALARM LED on Cisco ICS 7750 cards turns on (solid yellow) during the power-on self-test. If the ALARM LED on any card does not turn off at the completion of the power-on self-test, that card is not functioning correctly. If you installed DIMMs or PVDMs in the card that is not functioning correctly, remove the card, and verify that you installed the modules as directed in this document. For general information on solving problems with cards, refer to Chapter 5, "Solving Hardware Problems," in the Cisco ICS 7750 Administration and Troubleshooting Guide. |
| Card | LED | Verify the Following: |
|---|---|---|
MRP 200 | STATUS |
|
MRP 200 | SLOT 0 | Check this LED on all MRP cards that have a WAN interface card (WIC), voice WAN interface card (VWIC), or voice interface card (VIC) installed in Slot 0:
|
MRP 200 | SLOT 1 | Check this LED on all MRP cards that have a WIC, VWIC, or VIC installed in Slot 1:
|
SPE 200 | STATUS |
|
WIC or VIC cards | Depends on card | Refer to the Cisco WAN Interface Card Hardware Installation Guide to verify the LED activity for the specific cards that you installed in the Cisco ICS 7750. |
You can access the most current Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM is updated monthly. Therefore, it is probably more current than printed documentation. The CD-ROM package is available as a single unit or as an annual subscription.
Registered CCO users can order the Documentation CD-ROM and other Cisco Product documentation through our online Subscription Services at http://www.cisco.com/cgi-bin/subcat/kaojump.cgi.
Nonregistered CCO users can order documentation through a local account representative by calling Cisco's corporate headquarters (California, USA) at 408 526-4000 or, in North America, call 800 553-NETS (6387).
Cisco provides Cisco Connection Online (CCO) as a starting point for all technical assistance. Warranty or maintenance contract customers can use the Technical Assistance Center. All customers can submit technical feedback on Cisco documentation using the web, e-mail, a self-addressed stamped response card included in many printed docs, or by sending mail to Cisco.
Cisco continues to revolutionize how business is done on the Internet. Cisco Connection Online is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information and resources at anytime, from anywhere in the world. This highly integrated Internet application is a powerful, easy-to-use tool for doing business with Cisco.
CCO's broad range of features and services helps customers and partners to streamline business processes and improve productivity. Through CCO, you will find information about Cisco and our networking solutions, services, and programs. In addition, you can resolve technical issues with online support services, download and test software packages, and order Cisco learning materials and merchandise. Valuable online skill assessment, training, and certification programs are also available.
Customers and partners can self-register on CCO to obtain additional personalized information and services. Registered users may order products, check on the status of an order and view benefits specific to their relationships with Cisco.
You can access CCO in the following ways:
You can e-mail questions about using CCO to cco-team@cisco.com.
The Cisco Technical Assistance Center (TAC) is available to warranty or maintenance contract customers who need technical assistance with a Cisco product that is under warranty or covered by a maintenance contract.
To display the TAC web site that includes links to technical support information and software upgrades and for requesting TAC support, use www.cisco.com/techsupport.
To contact by e-mail, use one of the following:
Language | E-mail Address |
|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
In North America, TAC can be reached at 800 553-2447 or 408 526-7209. For other telephone numbers and TAC e-mail addresses worldwide, consult the following web site: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml.
If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco.
You can e-mail your comments to bug-doc@cisco.com.
To submit your comments by mail, for your convenience many documents contain a response card behind the front cover. Otherwise, you can mail your comments to the following address:
Cisco Systems, Inc.
Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate and value your comments.
This document is to be used in conjunction with the Cisco ICS 7750 Hardware Installation Guide publication.
Access Registrar, AccessPath, Any to Any, Are You Ready, AtmDirector, Browse with Me, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, the Cisco logo, Cisco Certified Internetwork Expert logo, CiscoLink, the Cisco Management Connection logo, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Capital, the Cisco Systems Capital logo, Cisco Systems Networking Academy, the Cisco Systems Networking Academy logo, the Cisco Technologies logo, Fast Step, FireRunner, Follow Me Browsing, FormShare, GigaStack, IGX, Intelligence in the Optical Core, Internet Quotient, IP/VC, IQ Breakthrough, IQ Expertise, IQ FastTrack, IQ Readiness Scorecard, The IQ Logo, Kernel Proxy, MGX, Natural Network Viewer, NetSonar, Network Registrar, the Networkers logo, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, RateMUX, ReyMaster, ReyView, ScriptShare, Secure Script, Shop with Me, SlideCast, SMARTnet, SVX, The Cell, TrafficDirector, TransPath, VlanDirector, Voice LAN, Wavelength Router, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are service marks; and Aironet, ASIST, BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, the Cisco Systems Cisco Press logo, CollisionFree, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastLink, FastPAD, FastSwitch, GeoTel, IOS, IP/TV, IPX, LightStream, LightSwitch, MICA, NetRanger, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0005R)
Installing and Upgrading Memory and Data Modules in the Cisco ICS 7750 SPE 200 Card and the MRP 200 Card
Copyright © 2000, Cisco Systems, Inc.
All rights reserved.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Oct 2 14:15:59 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.