Messages T03TR000 through T03TR899 are issued in the Trace address space. T03TR9nn messages are issued by the T03 Trace Facility in processing the OPTIONS= parameters of the TRACE CT,ON,COMP= command and the TRACE CT,OFF,COMP= command.

No T03TRnnn Message Displayed

If no T03TRnnnn message is displayed for your TRACE CT command, look for:

ITT004I START/STOP FAILED FOR TRACE COMP=ssidRETURN=00000008, REASON= nnnnnnnn.

Explanation    An error occurred and the return code and reason code were passed back to the TRACE CT command.

Recommended Action    Contact Customer Support.

T03TR000I

TRACE ssid initialization started

Explanation    The trace address space using subsystem id ssid has started initialization.

T03TR001I

TRACE ssid initialization successfully completed

Explanation    The trace address space using subsystem id ssid has completed initialization.

T03TR002I

TRACE ssid termination successfully complete

Explanation    The trace address space using subsystem id ssid has terminated.

T03TR003E

TRACE ssid initialization failed; reason code = rsn_code

Explanation    The trace address space using subsystem id ssid failed to initialize. The reason code is rsn_code.

Recommended Action    Contact Customer Support.

T03TR004E

STORAGE OBTAIN error for TAB (and TGV)- R15=ret_code R00=rsn_code

Explanation    Unable to obtain common storage.

Recommended Action    There may be a problem with CSA. If the problem persists, call Customer Support.

T03TR005E

DSPSERV CREATE error - R15=ret_code R00=rsn_code

Explanation    Could not create a data space for trace buffers.

Recommended Action    Call Customer Support.

T03TR006E

ALESERV ADD error - R15=ret_code R00=rsn_code

Explanation    Could not modify the primary address space access list.

Recommended Action    Call Customer Support.

T03TR007E

CTRACE DEFINE error - R15=ret_code R00=rsn_code

Explanation    Could not define our trace address space to the IBM component trace facility.

Recommended Action    Call Customer Support.

T03TR008E

STORAGE OBTAIN error for TIV - R15=ret_code R00=rsn_code

Explanation    Unable to obtain private storage.

Recommended Action    Check the REGION size. If the problem persists, call Customer Support.

T03TR101E

UNALLOWABLE FILTER KEYWORD

Explanation    A filter keyword was specified but is not allowed.

Recommended Action    Verify the filters for the specified group_id.

T03TR102E

HOST IP NAME/ADDRESS UNRESOLVABLE

Explanation    This is from the HOST(host) specification in the filter data. The host IP name was not able to be resolved using the specified DNR.

Recommended Action    Either use a dotted IP address or specify DNRSSID(ssid).

T03TR103E

PORT NAME OR NUMBER UNRESOLVABLE

Explanation    This is from the PORT(port) specification in the filter data. The name could not be converted or the number was invalid.

Recommended Action    Specify a well-known port name or use a valid number.

T03TR104E

PROTOCOL UNRESOLVABLE

Explanation    This is from the PROTOCOL(proto) specification in the filter data. The name could not be converted or the number was invalid.

Recommended Action    Specify a valid name or number.

T03TR901E

Abend xxxx occurred processing TRACE CT (+xxxx) Base(xxxxxxxx) PSW(xxxxxxxx)

Explanation    An abend occurred processing the reply.

Recommended Action    Contact Customer Support.

T03TR902E

Abend xxxx during TRACEUP/TRACEDN PC call

Explanation    An abend occurred in the Trace Address Space processing request.

Recommended Action    View the T01LOG, JESMSGLG and JESYSMSG to determine the error. Contact Customer Support with the logs available.

T03TR903E

Invalid OPTIONS specified

Explanation    A request was made to start, modify or stop a trace instance but the specified parameters where invalid.

Recommended Action    Review the OPTIONS= specification and re-issue the command with the necessary corrections.

T03TR904E

Instance(xx) is not an active trace

Explanation    A request was made to modify or stop a trace instance but the specified instance is not active.

Recommended Action    Verify that you are using the correct Instance ID. Issue R nn,OPTIONS=(STATUS),END to get a list of active instances. An instance could have been stopped by another operator.

T03TR905E

HALT specification requires Instance

Explanation    A request was made to stop a trace instance but the trace instance was not specified.

Recommended Action    Re-issue the command with INSTANCE(x) specified.

T03TR906E

Writer connection change requires Instance

Explanation    A request was made to change the connection status (connect or disconnect) but the WTR= keyword was specified without INSTANCE(nn).

Recommended Action    Re-issue the command with INSTANCE(nn) specified.

T03TR907E

Writer Disconnect invalid. Instance(xx) is not connected to writer

Explanation    A request was made to disconnect an external writer from a trace instance that was not connected to an external writer.

Recommended Action    Retry the command without requesting the writer be disconnected. Issue R nn,OPTIONS=(STATUS),END to get a list of active instances. An instance could have been stopped by another operator.

T03TR908E

Invalid GROUP name of gr_id

Explanation    GROUPS((group_id [,'filter')) was entered but the group id gr_id is not valid.

Recommended Action    Use one of the documented group names. See the Cisco IOS for S/390 System Management Guide for more information.

T03TR909I

Trace start successful Instance(xx)

Explanation    The shown trace instance was successfully started. Remember xx for any request that require INSTANCE(xx) in the specification.)

T03TR910I

Trace shutdown successful Instance(xx)

Explanation    The trace instance stop processing for the shown trace instance was successful.

T03TR911I

Trace modify successful Instance(xx)

Explanation    The trace instance modify processing for the shown trace instance was successful.

T03TR912E

Trace start error RC(xx) Reason(xx) Info(xxxx)

Explanation    The trace instance start processing failed. The return code and reason code are displayed.

Return Code Information:

RC=16 indicates T03CTSUP was entered without an ITCB, REGION size too small.

RC=12 implies the Trace Address space is not active.

RC=08 indicates an error occurred. The Reason Codes are:

for Invalid xxxx, the control block ID is not valid
01 Invalid Trace Instance
02 Invalid Trace Group ID see System Management Guide for valid names
03 DSPSERV Error - Info is Return Code from DSPSERV
04 TFE Storage Obtain Error - Info is Return Code from STORAGE
05 ITIM ALLOC Error - Info is Return Code from ITIME
06 Trace Address Space not Active
07 Max Trace Limit exceeded
09 Invalid TFPL
10 TFPL Storage Obtain Error - Info is Return Code from STORAGE
11 Invalid TAB
12 Invalid TIV
13 TSKB Storage Obtain/Release Error - Info is Return Code from STORAGE
14 Invalid TDSB
15 ILOAD Error for Sink Exit - Info is Return Code from ILOAD
16 T03STM2Q address error - address is zero
17 ITIME SET Error - Info is Return Code from ITIME
18 Invalid TSCB
19 TGV area size error - internal error with TGV allocation
20 Buffer request exceeds segment size
21 No free TSCB control blocks - internal error
22 Segment not on page boundary - internal error
23 DataSpace ALET error - Info is Return Code from TESTART
24 SFRR error - Info is Return Code from SFRR
25 ILOAD error for T03STBFF - Info is Return Code from ILOAD
30 Abend

Recommended Action    Contact Customer Support.

T03TR913E

Trace shutdown error for Instance(xx) RC(xx) Reason(xx) Info(xxxx)

Explanation    The trace instance stop processing failed. The return code and reason code are displayed.

Return Codes and Reason Codes:

RC=16 indicates T03CTTDN was entered without an ITCB, REGION size too small.
RC=12 implies the Trace Address space is not active.
RC=04 indicates an error occurred. The reason codes are:
for Invalid xxxx, the control block ID is not valid
01 Invalid Trace Instance
02 TSKB Storage Release Error - Info is Return Code from STORAGE
03 ITIM Error - Info is Return Code from ITIME
04 DSPSERV Release error - Info is Return Code from DSPSERV
05 Abend
06 Trace Address Space not Active
07 Invalid TAB
08 Invalid TIV
09 Invalid TGV
10 Invalid TFE
11 Invalid TFPL
12 Invalid TSKB
13 Invalid TSCB
14 Invalid TDSB
15 TGV area size error - internal error with TGV allocation
16 TFPL Storage release error - Info is Return Code from STORAGE
17 ECB Post error - Info is Return Code from POST
18 Flush Exit error - error from routine to flush buffers
19 ECB Storage Obtain/Release error - Info is Return Code from STORAGE
20 Buffer Flush error - Info is Return Code from ITIME
21 Invalid TBUF
22 TRTM Parm Storage Obtain/Release err - Info is Return Code from STORAGE
23 DataSpace ALET error - Info is Return Code from TESTART
24 ILOAD for T03STRTM failed - Info is Return Code from ILOAD
25 Tear Down already running - requested instance already being stopped

Recommended Action    Contact Customer Support.

T03TR914E

Trace modify error for Instance(xx) RC(xx) Reason(xx) Info(xxxx)

Explanation    A request to modify an instance failed. The return code and reason code are displayed. Refer to T03TR912E for more information.

Recommended Action    Contact Customer Support.

T03TR915E

Error processing Filter specification RC(xx) Reason(xx)

Explanation    An error occurred processing the filter parameter in a GROUPS specification.The return code and reason code are displayed.

Recommended Action    Verify that the filter applies to the specified group_id.

T03TR916I

Instance(xx) Active, records=records

Explanation    The results of STATUS show the active trace instances and the number of trace records that have been captured for the instance.

T03TR917E

Disconnect Writer before halting Instance

Explanation    A request was made to HALT a Trace Instance but the instance is still connected to an external writer.

Recommended Action    Either disconnect the writer, or specify WTR=DISCONNECT with the HALT request.

T03TR918I

No active Trace Instances

Explanation    In response to a STATUS request, there were no active traces.

Recommended Action    No action required.

T03TR919E

Writer Connect invalid for existing WRAP trace

Explanation    A WRAP type trace (default if WTR=writer is not specified) was started and a modify request with WTR=writer was attempted. A writer cannot be started for a WRAP type trace.

Recommended Action    Either start the trace with WTR=writer or start it specifying option NOWRAP in OPTIONS=(options).

hometocprevnextglossaryfeedbacksearchhelp