This section describes messages issued by the trace routine. These messages include T03TR000 through T03TR999.
Messages T03TR000 through T03TR899 are issued in the Trace address space. T03TR9nn messages are issued by the T03 Trace Facility in processing the OPTIONS= parameters of the TRACE CT,ON,COMP= command and the TRACE CT,OFF,COMP= command.
If no T03TRnnnn message is displayed for your TRACE CT command, look for:
ITT004I START/STOP FAILED FOR TRACE COMP=ssidRETURN=00000008, REASON= nnnnnnnn.Explanation An error occurred and the return code and reason code were passed back to the TRACE CT command.
Recommended Action Contact Customer Support.
Explanation The trace address space using subsystem id ssid has started initialization.
Explanation The trace address space using subsystem id ssid has completed initialization.
Explanation The trace address space using subsystem id ssid has terminated.
Explanation The trace address space using subsystem id ssid failed to initialize. The reason code is rsn_code.
Recommended Action Contact Customer Support.
Explanation Unable to obtain common storage.
Recommended Action There may be a problem with CSA. If the problem persists, call Customer Support.
Explanation Could not create a data space for trace buffers.
Recommended Action Call Customer Support.
Explanation Could not modify the primary address space access list.
Recommended Action Call Customer Support.
Explanation Could not define our trace address space to the IBM component trace facility.
Recommended Action Call Customer Support.
Explanation Unable to obtain private storage.
Recommended Action Check the REGION size. If the problem persists, call Customer Support.
Explanation A filter keyword was specified but is not allowed.
Recommended Action Verify the filters for the specified group_id.
Explanation This is from the HOST(host) specification in the filter data. The host IP name was not able to be resolved using the specified DNR.
Recommended Action Either use a dotted IP address or specify DNRSSID(ssid).
Explanation This is from the PORT(port) specification in the filter data. The name could not be converted or the number was invalid.
Recommended Action Specify a well-known port name or use a valid number.
Explanation This is from the PROTOCOL(proto) specification in the filter data. The name could not be converted or the number was invalid.
Recommended Action Specify a valid name or number.
Explanation An abend occurred processing the reply.
Recommended Action Contact Customer Support.
Explanation An abend occurred in the Trace Address Space processing request.
Recommended Action View the T01LOG, JESMSGLG and JESYSMSG to determine the error. Contact Customer Support with the logs available.
Explanation A request was made to start, modify or stop a trace instance but the specified parameters where invalid.
Recommended Action Review the OPTIONS= specification and re-issue the command with the necessary corrections.
Explanation A request was made to modify or stop a trace instance but the specified instance is not active.
Recommended Action Verify that you are using the correct Instance ID. Issue R nn,OPTIONS=(STATUS),END to get a list of active instances. An instance could have been stopped by another operator.
Explanation A request was made to stop a trace instance but the trace instance was not specified.
Recommended Action Re-issue the command with INSTANCE(x) specified.
Explanation A request was made to change the connection status (connect or disconnect) but the WTR= keyword was specified without INSTANCE(nn).
Recommended Action Re-issue the command with INSTANCE(nn) specified.
Explanation A request was made to disconnect an external writer from a trace instance that was not connected to an external writer.
Recommended Action Retry the command without requesting the writer be disconnected. Issue R nn,OPTIONS=(STATUS),END to get a list of active instances. An instance could have been stopped by another operator.
Explanation GROUPS((group_id [,'filter')) was entered but the group id gr_id is not valid.
Recommended Action Use one of the documented group names. See the Cisco IOS for S/390 System Management Guide for more information.
Explanation The shown trace instance was successfully started. Remember xx for any request that require INSTANCE(xx) in the specification.)
Explanation The trace instance stop processing for the shown trace instance was successful.
Explanation The trace instance modify processing for the shown trace instance was successful.
Explanation The trace instance start processing failed. The return code and reason code are displayed.
Return Code Information:
RC=16 indicates T03CTSUP was entered without an ITCB, REGION size too small.
RC=12 implies the Trace Address space is not active.
RC=08 indicates an error occurred. The Reason Codes are:
Recommended Action Contact Customer Support.
Explanation The trace instance stop processing failed. The return code and reason code are displayed.
Return Codes and Reason Codes:
Recommended Action Contact Customer Support.
Explanation A request to modify an instance failed. The return code and reason code are displayed. Refer to T03TR912E for more information.
Recommended Action Contact Customer Support.
Explanation An error occurred processing the filter parameter in a GROUPS specification.The return code and reason code are displayed.
Recommended Action Verify that the filter applies to the specified group_id.
Explanation The results of STATUS show the active trace instances and the number of trace records that have been captured for the instance.
Explanation A request was made to HALT a Trace Instance but the instance is still connected to an external writer.
Recommended Action Either disconnect the writer, or specify WTR=DISCONNECT with the HALT request.
Explanation In response to a STATUS request, there were no active traces.
Recommended Action No action required.
Explanation A WRAP type trace (default if WTR=writer is not specified) was started and a modify request with WTR=writer was attempted. A writer cannot be started for a WRAP type trace.
Recommended Action Either start the trace with WTR=writer or start it specifying option NOWRAP in OPTIONS=(options).
|
|