This chapter describes messages issued by the TCPEEP trace facility. These messages include T03PE001 through T03PE999.
Explanation TCPEEP has completed processing.
Explanation The Trace Address Space for subsystem ssid is not active. If TRCSSID(ssid) was not specified then the default subsystem ACTR is not active. If TRCSSID(ssid) was specified then that Trace address space is not active.
Recommended Action Either start the Trace address space or use TRCSSID(ssid) to use a Trace address space other than the default.
Explanation The HALT keyword was specified with the INSTANCE keyword.
Recommended Action Reissue the request specifying the INSTANCE keyword.
Explanation The Trace Address Space for subsystem ssid is not active. This usually means the Trace Address Space has never been started (since the last IPL). This address space is separate from the stack running TCP/IP. If TRCSSID(ssid) was not specified, then the default subsystem ACTR is not active. If TRCSSID(ssid) was specified, then that Trace address space is not active.
Recommended Action Either start the Trace address space or use TRCSSID(ssid) to use a Trace address space other than the default.
Explanation A request to start a new trace instance was made but the maximum number has already been reached.
Recommended Action Issue TRACE CT,ON,COMP=ssid and reply with: R nn,OPTIONS=(STATUS),END to display all the active traces. You must stop one of the active traces before initiating a new trace.
Explanation Either the group_id is too long, or the filter data is too long, or extraneous data after the filter specification was entered.
Recommended Action Verify the (group_id,'filter') specification is correct.
Explanation A group_id was entered that is invalid.
Recommended Action See the Cisco IOS for S/390 System Management Guide for valid names.
Explanation An invalid combination of parameters were entered, e.g. HALT and SYSOUT.
Recommended Action See the syntax in Cisco IOS for S/390 System Management Guide.
Explanation This is issued in response to an attention interrupt (ATTN key for LU2 or PA1 for LU0).
Recommended Action To continue the trace hit the ENTER key with no data. To stop the trace, enter H.
Explanation A dynamically allocated SYSOUT data set has been allocated.
Explanation A trace has been started with instance number nn.
Explanation An abend occurred. Various SDWA fields are displayed.
Recommended Action Contact Customer Support.
Explanation An error occurred initiating a trace.
Recommended Action Contact Customer Support.
Explanation An error occurred stopping a trace.
Recommended Action Contact Customer Support.
Explanation An error occurred retrieving trace data.
Recommended Action Contact Customer Support.
Explanation An error occurred during dynamic allocation.
Recommended Action Contact Customer Support.
Explanation An error occurred during OPEN for the dynamically allocated SYSOUT data set.
Recommended Action Contact Customer Support.
Explanation An error occurred generating the filter. func is either STOR or PARS for STORAGE or IKJPARS respectively.
Recommended Action If func is PARS make sure the filter parameters are valid.
Explanation An error occurred trying to load module.
Recommended Action Make sure the LINK library is either in the STEPLIB or Link-List.
Explanation An error occurred trying to obtain storage.
Recommended Action Inspect the REGION size for TSO.
|
|