cc/td/doc/product/software/ioss390
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

T03PEnnn - TCPEEP Messages

T03PEnnn - TCPEEP Messages

This chapter describes messages issued by the TCPEEP trace facility. These messages include T03PE001 through T03PE999.

T03PEnnn

T03PE000I

TCPEEP Processing Completed

Explanation    TCPEEP has completed processing.

T03PE001E

The Trace A.S. (Subsystem Id ssid) is not active

Explanation    The Trace Address Space for subsystem ssid is not active. If TRCSSID(ssid) was not specified then the default subsystem ACTR is not active. If TRCSSID(ssid) was specified then that Trace address space is not active.

Recommended Action    Either start the Trace address space or use TRCSSID(ssid) to use a Trace address space other than the default.

T03PE002E

HALT REQUEST REQUIRES INSTANCE

Explanation    The HALT keyword was specified with the INSTANCE keyword.

Recommended Action    Reissue the request specifying the INSTANCE keyword.

T03PE003E

TCPEEP requires a Trace Address Space separate from TCP/IP
The Trace A.S. (Subsystem Id ssid) is not active.
TCPEEP cannot initialize without the Trace Address Space

Explanation    The Trace Address Space for subsystem ssid is not active. This usually means the Trace Address Space has never been started (since the last IPL). This address space is separate from the stack running TCP/IP. If TRCSSID(ssid) was not specified, then the default subsystem ACTR is not active. If TRCSSID(ssid) was specified, then that Trace address space is not active.

Recommended Action    Either start the Trace address space or use TRCSSID(ssid) to use a Trace address space other than the default.

T03PE004E

MAXIMUM TRACE INSTANCES ALREADY ACTIVE

Explanation    A request to start a new trace instance was made but the maximum number has already been reached.

Recommended Action    Issue TRACE CT,ON,COMP=ssid and reply with: R nn,OPTIONS=(STATUS),END to display all the active traces. You must stop one of the active traces before initiating a new trace.

T03PE005E

ERROR PARSING GROUPS

Explanation    Either the group_id is too long, or the filter data is too long, or extraneous data after the filter specification was entered.

Recommended Action    Verify the (group_id,'filter') specification is correct.

T03PE006E

Invalid GROUP name group_id

Explanation    A group_id was entered that is invalid.

Recommended Action    See the Cisco IOS for S/390 System Management Guide for valid names.

T03PE007E

Invalid combination of parameters

Explanation    An invalid combination of parameters were entered, e.g. HALT and SYSOUT.

Recommended Action    See the syntax in Cisco IOS for S/390 System Management Guide.

T03PE008I

nnnn RECORDS, ENTER 'H' TO HALT TCPEEP TRACE

Explanation    This is issued in response to an attention interrupt (ATTN key for LU2 or PA1 for LU0).

Recommended Action    To continue the trace hit the ENTER key with no data. To stop the trace, enter H.

T03PE009I

SYSOUT allocated to ddname

Explanation    A dynamically allocated SYSOUT data set has been allocated.

T03PE010I

TRACE INITIATED - INSTANCE: nn

Explanation    A trace has been started with instance number nn.

T03PE011S

Abend SDWANAME SDWAMODN SDWACMPC SDWAGR12 SDWANXT1

Explanation    An abend occurred. Various SDWA fields are displayed.

Recommended Action    Contact Customer Support.

T03PE012E

TRACE UP FAILED: RC=rc RSN=reason

Explanation    An error occurred initiating a trace.

Recommended Action    Contact Customer Support.

T03PE013E

TRACE DOWN FAILED: RC=rc RSN=reason

Explanation    An error occurred stopping a trace.

Recommended Action    Contact Customer Support.

T03PE014E

TRACE READ FAILED: RC=rc RSN=reason

Explanation    An error occurred retrieving trace data.

Recommended Action    Contact Customer Support.

T03PE020E

SYSOUT ALLOCATION ERROR RC=rc ERR=error INFO=info

Explanation    An error occurred during dynamic allocation.

Recommended Action    Contact Customer Support.

T03PE021E

Error OPENing SYSOUT RC=rc

Explanation    An error occurred during OPEN for the dynamically allocated SYSOUT data set.

Recommended Action    Contact Customer Support.

T03PE022E

Error Generating FILTER RC=rc CC=cc func

Explanation    An error occurred generating the filter. func is either STOR or PARS for STORAGE or IKJPARS respectively.

Recommended Action    If func is PARS make sure the filter parameters are valid.

T03PE023E

Error LOADing module

Explanation    An error occurred trying to load module.

Recommended Action    Make sure the LINK library is either in the STEPLIB or Link-List.

T03PE024E

No STORAGE for PROGRAM Table

Explanation    An error occurred trying to obtain storage.

Recommended Action    Inspect the REGION size for TSO.

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1998 © Cisco Systems Inc.