This chapter describes messages written by the Cisco IOS for S/390 OpenEdition (UNIX System Services) interface. These messages are T01OE000 through T01OE999.
Messages in this range detail information about the network protocol layers, Transmission Control Protocol (TCP), Internet Protocol (IP), Internet Control Message Protocol (ICMP), and User Datagram Protocol (UDP). These messages help someone familiar with the TCP/IP suite of protocols to troubleshoot problems arising in this area on the local system, remote system, or network.
Explanation A call to module mod_name failed with a return value of value, a return code of ret_code, and a reason code of rsn_code.
This could be a normal message if the module is BPXVOSIT and OpenEdition is not running at the time of the message.
Recommended Action Check the logs for other related error messages. Let the other messages guide your action.
If ret_code is EMVSINITIAL (x'9C') and rsn_code is in the range of JRSAFnoUser (x'F9') - JRSAFInternal (x'FE'), the OpenEdition PFS will not be operational until the RACF configuration error has been corrected and the Cisco IOS for S/390 region has been recycled.
If ret_code is EACCESS (x'6F'), and if the address family is AF_INET and the PFS is configured to work under the control of converged sockets (that is. it needs a master socket to operate), the OpenEdition Cisco IOS for S/390 PFS will not be operational until the RACF configuration error is corrected and the Cisco IOS for S/390 address space recycled.
Explanation A load request for module mod_name failed with a ABEND code of abend_code and a reason code of rsn_code.
Recommended Action If OpenEdition is running at your installation and the module name is BPXVOSIT make sure its library is in the link list.
Explanation A cross memory connection has been established between the ACP task group and the OpenEdition address space to support Socket API functions. The name of the provider in the OpenEdition address space is provider.
Explanation The cross memory connection to OpenEdition address space was shutdown normally.
Recommended Action Determine why OpenEdition terminated. Restart OpenEdition to re-establish socket connectivity.
Explanation The cross memory connection to OpenEdition address space was shutdown abortively.
Recommended Action Determine why OpenEdition terminated. Restart OpenEdition to re-establish socket connectivity.
Explanation An attempt to establish connection with OpenEdition failed because the module indicated could not be located. This is an installation error.
Recommended Action If the module name mod_name is BPXmmmmm, check installation of OpenEdition.
Explanation Message generated for diagnostic purposes.
Recommended Action Check for an SVC dump titled Cisco IOS for S/390 T01AMSCK - Abended T01AMSCK=00000000, MWA=00X000000, DB#A=000000000. Contact Customer Support.
Explanation Initialization of the OpenEdition Cisco IOS for S/390 PFS named pfs_name has begun.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name is using the Cisco IOS for S/390 address space with the subsystem identifier of subsys_name.
Explanation Initialization of the OpenEdition Cisco IOS for S/390 PFS named pfs_name has successfully completed.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has attached a subtask with a Task Control Block (TCB) located at address tcb_address in the OpenEdition address space.
Explanation Initialization of the OpenEdition Cisco IOS for S/390 PFS named pfs_name has failed.
Recommended Action Check for any prior error messages issued from this PFS. Correct any incorrect configuration statements and restart OpenEdition.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name subtask located at address tcb_address in the OpenEdition address space, terminated unexpectedly.
Recommended Action Locate any error prior error message which may explain why the subtask prematurely terminated. The subtask will automatically be restarted.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has begun to terminate.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name attempted to load module mod_name into storage but failed with an ABEND code of abend_code and a reason code of rsn_code.
Recommended Action Determine why the LOAD failed by using code as a reference. The most probable causes are that the specified module is not in a data set in the STEPLIB concatenation, insufficient storage exists in the region or the load data set has gone into secondary extents after OpenEdition started.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has processed the NETWORK statement with a TYPE of type, DOMAINNAME of domain_name, DOMAINNUMBER of domain_number and MAXSOCKETS of sockets.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has determined the Cisco IOS for S/390 address space with a subsystem identifier of subsys_name does not have an operational OpenEdition PFS Transport Provider active.
Recommended Action Verify that the Cisco IOS for S/390 address space is executing on the same processor with a subsystem identifier of subsys_name. If Cisco IOS for S/390 is not active, start Cisco IOS for S/390. If Cisco IOS for S/390 is active, verify that the TCP task group is active and if not, restart it.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name was configured to support the Domain domain_number. This domain is not supported by the Cisco IOS for S/390 PFS.
Recommended Action Correct the domain number and restart OpenEdition. If the condition continues, contact Customer Support.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name was attempting to allocate the inode pool via a Storage Obtain system call. The call failed with a return code of ret_code.
Recommended Action Use the return code from the Storage Obtain call to determine why the call failed. If the call failed for insufficient virtual storage in the region, either increase the region size or decrease the maximum number of sockets.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name was attempting to create a Named Token with name token_name, but the call to IEANTCR returned with return code 4, indicating the Named Token already exists. token_value is the value of token as reported by the IEANTRT service. The specified token is deleted by calling IEANTDL and an attempt is made to recreate the Named Token by calling IEANTCR a second time.
Recommended Action The probable cause of this message is the definition of multiple PFS' within OpenEdition that have the same Cisco IOS for S/390 subsystem as the TCP service provider. A single Cisco IOS for S/390 address space can only service one PFS per MVS. Correct the PFS definitions to point to separate Cisco IOS for S/390 address space or remove the duplicate definitions.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name issued a call to the MVS Named Token Function function_name and the call returned an error code indicating a permanent error had occurred.
Recommended Action Determine the cause of the error by locating error code error_code for service function_name in IBM manual MVS/ESA SP V5 AUTHORIZED ASSEMBLER SERVICES REFERENCE ENF-ITT, GC28-1476-00. Follow the recommend action for the error to correct the problem.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has begun the listing of configuration parameter data. This message may be followed by message T01OE116I.
Explanation This is a continuation message for T01OE115I and will be repeated until all configuration parameter data has been listed.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has encountered invalid configuration parameter data.
Recommended Action Correct the parameter data and restart OpenEdition.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has determined that a configuration keyword was invalid or not specified.
Recommended Action Correct the required keyword parameter and restart OpenEdition.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has determined that a configuration keyword specified incorrect or omitted parameter data.
Recommended Action Correct the keyword parameter data and restart OpenEdition.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has determined that a configuration keyword parameter data was specified incorrectly.
Recommended Action Correct the keyword parameter data and restart OpenEdition.
Explanation The OpenEdition Cisco IOS for S/390 PFS named pfs_name has detected an ABEND abend_code having occurred in a subtask while processing the specified subcommand. The addresses of various control blocks are specified by addr to assist in problem determination.
Recommended Action This condition indicates an internal error in T010PST. Contact local Cisco IOS for S/390 personnel unless the problem was caused by some operational type problem (for example, OpenEdition canceled, insufficient virtual storage, etc.).
|
|