cc/td/doc/product/software/ioss390
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

T00IFnnn - IFS Messages

T00IFnnn - IFS Messages

This chapter describes the messages issued by the Infrastructure (IFS) program. These include messages T00IF001 through T00IF999.

T00IFnnn

T00IF001I

Address space initialization beginning

Explanation    An IFS-type address space has been started by an MVS operator command.

T00IF002I

Address space initialization complete

Explanation    Basic address space initialization is complete. Initialization includes establishing a long-term enqueue to prevent a second copy of this address space from starting, identifying PC call tables to MVS, identifying an extended ECB exit to MVS, and initializing the job step task.

T00IF003E

Address space already started (ENQ failed)

Explanation    During initialization of the address space, the long-term enqueue has failed. This means that another address space with the same definition type must already be active.

Recommended Action    Terminate the existing address space, or direct commands to the existing address space if it performs the desired functions.

T00IF004I

Task #task_num started for ver.rel

Explanation    A task, in response to a START command, has completed initialization.

T00IF005I

Task #task_num stopped for tg_name

Explanation    A task, in response to a STOP command, has terminated. The parameter tg_name indicates the task group name.

T00IF006E

uniq prfx itgb tgid tg_name Task initialization exit failed,
    task terminating

Explanation    An error occurred during task initialization.

Syntax Description
uniq Unique name of the address space where the failure occurred.
prfx Prefix name of the address space where the failure occurred.
itgb String ITGB, indicating IFS Task Group Block.
tgid Task group identifier.
tg_name Task group name.

Recommended Action    Call Customer Support.

T00IF007E

uniq prfx itgb tg_id tg_name Error processing EQT, attempting recovery

Explanation    A task group error occurred while holding the MVS local lock. A Functional Recovery Routine has gained control.

Syntax Description
uniq Unique name of the address space where the failure occurred.
prfx Prefix name of the address space where the failure occurred.
itgb String ITGB, indicating IFS Task Group Block.
tg_id Task group identifier.
tg_name Task group name.

Recommended Action    Call Customer Support.

T00IF008E

uniq prfx itgb tg_id tg_name Error in wait, attempting recovery

Explanation    A task group error occurred during MVS wait. A Functional Recovery Routine has gained control.

Syntax Description
uniq Unique name of the address space where the failure occurred.
prfx Prefix name of the address space where the failure occurred.
itgb String ITGB, indicating IFS Task Group Block.
tg_id Task group identifier.
tg_name Task group name.

Recommended Action    Call Customer Support.

T00IF009E

uniq prfx itgb tg_id tg_name Error during dispatch, attempting recovery

Explanation    A task group error occurred during local dispatching. A Functional Recovery Routine has gained control.

Syntax Description
uniq Unique name of the address space where the failure occurred.
prfx Prefix name of the address space where the failure occurred.
itgb String ITGB, indicating IFS Task Group Block.
tg_id Task group identifier.
tg_name Task group name.

Recommended Action    Call Customer Support.

T00IF010E

uniq prfx itgb tg_id tg_name Error after post, task terminating

Explanation    A task group error occurred after MVS post. A Functional Recovery Routine has gained control.

Syntax Description
uniq Unique name of the address space where the failure occurred.
prfx Prefix name of the address space where the failure occurred.
itgb String ITGB, indicating IFS Task Group Block.
tg_id Task group identifier.
tg_name Task group name.

Recommended Action    Call Customer Support.

T00IF011E

uniq prfx itgb tg_id tg_name Error ISRB termination

Explanation    A task group error occurred during local dispatching. A Functional Recovery Routine has gained control.

Syntax Description
uniq Unique name of the address space where the failure occurred.
prfx Prefix name of the address space where the failure occurred.
itgb String ITGB, indicating IFS Task Group Block.
tg_id Task group identifier.
tg_name Task group name.

Recommended Action    Call Customer Support.

T00IF012E

uniq prfx itgb tg_id tg_name Error resuming ISRB

Explanation    A task group error occurred during resume dispatching. A Functional Recovery Routine has gained control.

Syntax Description
uniq Unique name of the address space where the failure occurred.
prfx Prefix name of the address space where the failure occurred.
itgb String ITGB, indicating IFS Task Group Block.
tg_id Task group identifier.
tg_name Task group name.

Recommended Action    Call Customer Support.

T00IF013I

Parse failed for command cmnd_name in member mem_name, RC=ret_code

Explanation    TSO parse service routines failed while parsing an operator command. This occurs when the command syntax has been confused or is incorrect. Special characters can also cause parse failures.

Another condition which can generate this error occurs when the Subsystem Recognition Character (SRC) is set to the same as that used by JES (JES2 uses $, JES3 uses *).

The variable ret_code is a decimal return code from the TSO Parse Service routine. The return code is one of the following:

Recommended Action    Try to reenter a correct command or eliminate special characters.

If your SRC is either $ or *, check with your JES Systems Programmer about what character you can use.

T00IF014I

Invalid verb cmnd_name for task tg_id

Explanation    An invalid command verb was directed to the task group. The command was directed to the task group explicitly.

Recommended Action    Try to reenter a correct command verb, direct it to another task, or omit the task group from the command.

T00IF015W

Task group ID required

Explanation    A START or STOP command was issued, but the required task group type was not supplied with the command.

Recommended Action    Reissue the command, specifying a three-character task group name with the start command.

T00IF016W

Task group ID tg_id not found

Explanation    A START, STOP, SET, or TASK command was issued, but the requested task group type is invalid or the component is not installed. The variable tg_id identifies the task group.

Recommended Action    Specify a valid three-character task group name and reissue the command.

T00IF017W

Maximum tasks active for group ID tg_id

Explanation    A START command was issued, but the requested task group already has the maximum number of active tasks permitted. The variable tg_id identifies the task group.

Recommended Action    Usable subtasks for the requested task group should already be active. Display them with the TASK command. If no tasks exist and none can be started, stop and restart the address space where the problem occurred.

T00IF018W

No tasks active or matching for group ID tg_id

Explanation    A STOP command was issued, but the requested task group type has no active subtasks. The variable tg_id identifies the task group.

Recommended Action    Correct the command syntax and retry.

T00IF019W

Invalid task group ID--tg_id

Explanation    A START, STOP, SET or TASK command was issued, but the format of the requested task group specification is incorrect. The variable tg_id identifies the task group.

Recommended Action    Specify a valid three-character task group name and reissue the command.

T00IF020I

Snap complete to class cls_name

Explanation    An operator requested, or ABEND initiated snap is complete. The variable cls_name, identifies the JES SYSOUT class to which the snap was dynamically allocated.

Recommended Action    If the class is serviced by a JES printer, it is printed. If the class is not serviced by a JES printer, an external writer procedure must be initiated to collect the snap output.

T00IF021I

Page services, object_type object_name action failed reason=rsn_code

Explanation    A request for page-fix or page-free service failed.

Possible object types are the following:

Possible actions are the following:

The variable rsn_code is a decimal reason number for the failure; either 4 (module nonexistent) or 16 (A(object)=0).

T00IF022I

Storage at stor_addr in KEY key

Explanation    Displays main storage. In the message text, the hexadecimal parameter stor_addr is the beginning address of the storage being displayed, and key is the storage key.

T00IF023I

c_blk at stor_addr

Explanation    Displays a control block in main storage. The variable stor_addr is the beginning address, in hexadecimal, of the storage displayed.

T00IF024I

addr +disp wrd1 wrd2 wrd3 wrd4 *chars16*

Explanation    Displays main storage. Shows sixteen bytes per line.

Syntax Description
addr Virtual address.
disp Displacement from the beginning address of the storage being displayed, in hexadecimal display form.
wrd1 Contents of the first word in hexadecimal display form.
wrd2 Contents of the second word in hexadecimal display form.
wrd3 Contents of the third word in hexadecimal display form.
wrd4 Contents of the fourth word in hexadecimal display form.
chars16 Contents of the four words in character display form.

T00IF025I

Maintenance level for tg_name ver.rel

Explanation    Displays the component maintenance status in response to a status command.

T00IF026I

Route code(rt_code) now set

Explanation    This is a response to a $ROUTE command to either display or vary Route Codes for a task group. The variable rt_code is a string of route code numbers representing the current settings in effect for the task group.

T00IF027I

Route code value out of range (1-16)

Explanation    This is a response to a $ROUTE command vary Route Codes for a task group. There is a value in the new route code specification outside the acceptable range of values of 1 to 16.

Recommended Action    The request is ignored. Reenter the request, if desired, with a set of correct route code values.

T00IF028I

Console ID cons_id, console area area_id set

This is a response to a $CON command to either display or vary Console Routing for a task group. The parameter cons_id is a hexadecimal word representing the current task console routing.

IF the first half of the word is...

THEN the...

nonzero routing is to a TSO terminal.
zero second half word represents a one byte console ID and a one byte area ID for that console.

area_id corresponds to the WTO AREAID option and forces WTO descriptor codes to 8 and 9.

T00IF029E

Authorization key length invalid

Explanation    This is an error message from the Component Authorization facility. The key entered in the AUTH statement of the IJTCFG00 member is not the correct length. This message will also appear on the console log.

Recommended Action    Examine the IJTCFG00 member of the PARM data set. Edit the KEY field with the correct key from the Component Authorization form. Stop and restart Cisco IOS for S/390 for the new key to take effect. If the message is repeated, contact Customer Support.

T00IF030E

Authorization key validation failed!

Explanation    This message reports an error detected by the Component Authorization facility. This message will also appear on the console log.

Recommended Action   

T00IF031E

CPU ID not authorized to execute product

Explanation    An error was detected by the Component Authorization facility. You may not run the Cisco IOS for S/390 product on this CPU. This message will also appear on the console log.

Recommended Action    Verify your CPU ID and contact Customer Support.

T00IF032E

Parsing error occurred in AUTH statement; command buffer follows:

Explanation    An error was detected by the Component Authorization facility parsing the AUTH statement of the IJTCFG00 member. This message will also appear on the console log.

Recommended Action    Examine the IJTCFG00 member of the PARM data set. Verify that the AUTH statement has the correct number of parentheses and that the key and customer number were entered correctly.

T00IF033E

Use of TCP/IP is no longer permitted

Explanation    The Component Authorization facility has determined that an attempt has been made to start TCP/IP past the expiration date encoded in the authorization key. This message will also appear on the console log.

Recommended Action    Contact Customer Support for a new authorization key.

T00IF034E

Module mod_name ILATCH function_name failure for latch latch_name,
    latch addr=ltach_addr, rtn code=ret_code

Explanation    IILATCH call for function function_name for latch latch_name failed with a return code of ret_code. The latch address is at location latch_addr.

Recommended Action    This problem should not occur during normal operation. Look for related messages in the logs. Dump the address space via the operator console and contact Customer Support.

Issue the "/f jobname,ilatch free" command to free any held latches.

T00IF035E

TCP unable to allocate a timer element.

Explanation    TCP was unable to allocate a timer element for a new connection. Either there are the maximum number of connections active or there was no virtual storage for the timer element.

Recommended Action    Increase the virtual storage available to the address space or retry the connection when there are fewer other connections.

T00IF036E

Required statement, AUTH, missing from IJTCFG00

Explanation    An error was detected by the Component Authorization facility parsing the IJTCFG00 member. The AUTH statement is required for component authorization. This message will also appear on the console log.

Recommended Action    Edit the IJTCFG00 member of the PARM data set to include the AUTH statement, including the CUSTNUM and KEY fields. Contact Customer Support if you don't know your customer number or key.

T00IF037E

Authorization for 1 or more features will expire in nnnn days

Explanation    The Component Authorization facility has determined that the expiration date for one or more of the features of Cisco IOS for S/390 will arrive in nnnn days. This message will also appear on the console log.

Recommended Action    Contact Customer Support for a new component authorization key.

T00IF038W

The following latch has been held over number seconds:

Explanation    A latch has been found that has been held for too long. number is the number of seconds used to determine if the latch has been held too long.

Recommended Action    Use the ILATCH DISPLAY command to determine who is holding the latch. Consider terminating that user; consider using the ILATCH FREE command to release the latch.

T00IF039I

Freeing the following Latch:

Explanation    A latch is being freed by the ILATCH command processor. Subsequent messages will display information about the latch being freed.

T00IF040E

Unable to Free the previous latch: (RC = ret_code).

Explanation    The ILATCH command processor was unable to free a latch as requested. ret_code is the return code from the ILATCH FREE call.

Recommended Action    Contact Customer Support and tell them the return code from the message.

T00IF041I

End of ILATCH command.

Explanation    This is the end of processing a ILATCH command.

T00IF042E

No latch work area allocated.

Explanation    The ILATCH command processor was unable to locate the Latch Work Area and is unable to process the command. The Latch Work Area should be allocated as part of initialization.

Recommended Action    Contact Customer Support.

T00IF043E

No level 1 latch map allocated.

Explanation    The ILATCH command processor was unable to locate the Level 1 Latch Map, and is unable to process the command. The Level 1 Latch Map should be allocated as part of initialization.

Recommended Action    Contact Customer Support.

T00IF044E

No level 2 latch map allocated.

Explanation    The ILATCH command processor was unable to locate the Level 2 Latch Map and is unable to process the command. The Level 2 Latch Map should be allocated as part of initialization.

Recommended Action    Contact Customer Support.

T00IF045I

ILATCH display

Explanation    A latch is being displayed. This message will be followed by messages T00IF046I and T00IF047I for exclusive latches, or T00IF057I and T00IF058I for shared latches.

T00IF046I

Latch#    Addr       Asid     ASCB      ITCB     RB/Token  Jobname   Time

Explanation    Header information for message T00IF047I.

T00IF047I

latchnum  latchaddr  addr_id   ASCBaddr  TCBaddr  RBaddr    jobname   time

Explanation    This message is the result of processing an ILATCH command that displays exclusive latches. The latch number specified in the command either was not currently held, or was held less than the specified (or default) time value.

Explanation    Enter the ILATCH DISPLAY command to determine if the latch number is still held, or the amount of time it has been held. Then re-enter the ILATCH command as desired.

Syntax Description
latchnum Latch number.
latchaddr Latch block address.
addr_id Address space ID of the holder of the latch.
ASCBaddr Address of the ASCB of the holder of the latch.
TCBaddr TCB address or the SRB address.
rbaddr RB address or the first 8 bytes of the SRB token.
jobname As displayed by SDSF DA command.
time Number of seconds the latch has been held.

T00IF048W

Requested latch not found.

Explanation    The requested latch is not being held or has not been held as long as the TIME operand of the ILATCH command specifies.

Recommended Action    Specify a different TIME keyword or a different latch number. Or it is possible the specified latch is no longer held.

T00IF049E

Load failed for routine routine_name, abend code=abend_code,
    reason code=reason_code

Explanation    The routine routine_name failed with the abend code specified.

Recommended Action    Notify Customer Support.

T00IF050E

*Abend* Ssabnd/Uuabnd in module mod_id mod_size

Explanation    A standard IFS recovery routine has gained control from a module ABEND situation and is displaying the ABEND situation.

Syntax Description
sabnd MVS system ABEND code (hexadecimal).
uabnd Application user ABEND code (decimal).
mod_id Module identification, including CSECT name, assembly time and date, and version and level of the module.
mod_size Size of the module in bytes (hexadecimal).

Recommended Action    Notify Customer Support.

T00IF051E

Psw=psw1 psw2 Intc=icde Instr=idata Displ=disp

Explanation    The PSW, interrupt code, failing instruction, and displacement of the failure in a module (if possible) are formatted. See message T00IF050E.

Syntax Description
psw1 First word, in hexadecimal, of the Program Status Word at time of failure
psw2 Second word of the Program Status Word at time of failure. This word contains the address of the failing instruction (hexadecimal).
icde Hexadecimal interrupt code causing the failure
idata Failing instruction (hexadecimal)
disp Displacement of the failing instruction in the ABENDing module, in hexadecimal

Recommended Action    Notify Customer Support.

T00IF052W

Tg: tg_id tg_name itgb itcb flg1 flg2 tcb csrb

Explanation    This message contains information formatted for the task group associated with the ABEND. See message T00IF050E.

Syntax Description
tg_id Task group ID.
tg_name Task group name.
itgb Hexadecimal address of the failing IFS Task Group Block.
itcb Hexadecimal address of the failing IFS Task Control Block.
flg1 Hexadecimal value of flag1 in the IFS Task Control Block.
flg2 Hexadecimal value of flag2 in the IFS Task Control Block.
tcb Hexadecimal address of the failing MVS Task Control Block.
csrb Hexadecimal address of the associated IFS Command SRB.

Recommended Action    Notify Customer Support.

T00IF053W

Regs r1-r2 reg1 reg2 reg3 reg4

Explanation    This message contains formatted register information associated with the ABEND. This line appears four times, each time with four of the sixteen hexadecimal registers. See message T00IF050E.

Syntax Description
r1 First register shown on the line, either 0, 4, 8, or C.
r2 Last register shown on the line, either 3, 7, 9, or F.
reg1 Value of the first register in the group, 0, 4, 8, or 12.
reg2 Value of the second register in the group, 1, 5, 9, or 13.
reg3 Value of the third register in the group, 2, 6, 10, or 14.
reg4 Value of the fourth register in the group, 3, 7, 11, or 15.

Recommended Action    Notify Customer Support.

T00IF054W

Sdwafgls = erra errb errc errd

Explanation    This message contains formatted information from the MVS System Diagnostic Work Area associated with the ABEND. See message T00IF050E.

Syntax Description
erra Hexadecimal value of the byte known as SDWAERRA.
errb Hexadecimal value of the byte known as SDWAERRB.
errc Hexadecimal value of the byte known as SDWAERRC.
errd Hexadecimal value of the byte known as SDWAERRD.

Recommended Action    Notify Customer Support.

T00IF055I

VTAM interface installed, A(VCVT)=vcvt

Explanation    This message is in response to a VTAM command, showing the address of the VTAM Communication Vector Table built. The single parameter, vcvt, is the hexadecimal address of the VTAM CVT.

T00IF056I

VTAM interface already installed, A(VCVT)=vcvt

Explanation    This message is in response to a VTAM command, showing the address of the VTAM Communication Vector Table that has already been installed by a previous VTAM command. The single parameter, vcvt, is the address of the VTAM CVT.

T00IF057I

Latch#         Addr           Shr_cnt      Time

Explanation    Header information for message T00IF058I.

T00IF058I

latch_num      latch_addr     Shr_cnt      time_held

Explanation    This message is the result of processing an ILATCH command that displays shared latches. The latch number specified in the command either was not currently held, or was held less than the specified (or default) time value.

Explanation    Enter the ILATCH DISPLAY command to determine if the latch number is still held, or the amount of time it has been held. Then re-enter the ILATCH command as desired.

Syntax Description
latch_num Latch number.
latch_addr Latch block address.
Shr_cnt Shared count.
time_held Number of seconds the latch has been held.

T00IF059I

Not authorized for Fault Tolerance

Explanation    If the Fault Tolerance option is not installed, the startup sequence will fail with this message if either the IP statement contains the GATED keyword, or if the MEDIA statement contains the IDLENET keyword.

T00IF060E

Unknown abend parameter specification (abend_code)

Explanation    There was a syntax error on the ABEND command. The allowable values are S0C1-S0CF, and S806.

Recommended Action    Correct the syntax and retry.

T00IF062I

Log started

Explanation    A date stamp of the start of the log file.

T00IF063E

Address space terminating in error

T00IF064E

Incompatible releases using same subsystem name

T00IF065E

Restart prior running release; issue P CLEAR. Restart current release (xxxx)

Explanation    Messages T00IF063E, T00IF064E, and T00IF065E always display together.

An incompatibly was recognized between a system startup stage and residual components from the previous running system. The residual components are still resident because the previous termination did not specify a P,CLEAR option.

Recommended Action    Reactivate the previous version of TCP/IP, terminate it with the CLEAR option, then restart the newer version.

T00IF066I

Virtual storage statistics: vvv bytes available above/below the line,     uu% used, mm% min, xx% max

Explanation    This message displays an estimate of the used and available virtual storage, first for the below-the-line area, then for above-the-line. The numbers are extracted from the VSMLIST statistics as reported by MVS. The available byte values are based on subtraction from the region size.

Explanation    Message display and frequency is governed by the VSREPORT keyword of the IFSPARM statement in the IJTCFGxx member. Statistics are recalculated with each display to insure accuracy.

Syntax Description
vvv Current amount of unallocated virtual storage, in bytes.
above/below Either ABOVE or BELOW the 16MB line.
uu Current amount used, expressed as a percentage of the region size.
mm Minimum amount used, expressed as a percentage of the region size.
xx Maximum amount used, expressed as a percentage of the region size.

T00IF067I

Region size is value1, value2 below the line

Explanation    Both region sizes are displayed for the Cisco IOS for S/390 job as byte counts.

The region size specifies the maximum amount of storage that can be allocated to the Cisco IOS for S/390 job by any single variable-length GETMAIN request. Depending on how the region size was requested, it may include the region above 16MB. The below-the-line value specifies the maximum total storage that can be allocated to below-the-line requests.

Explanation    These values are set by the IBM-supplied or installation-written exit routine. The region size usually is set equal to the REGION parameter specified by the Cisco IOS for S/390 JCL (or installation default if not specified), and the region size limit is usually equal to the region size plus 64K.

Syntax Description
value1 The region size registered.
value2 The size of the region below the 16MB line.

T00IF068I

Date is date

Explanation    This message displays during a message logging procedure when a date change is detected. It identifies subsequent log entries with their appropriate logging date.


Note With the exception of T00IF071E, all messages between T00IF070D and T00IF088D display only when security monitoring is activated via the XSEC statement in the IJTCFGxx member. The security functions to be monitored are specified as keyword selections on the XSEC statement, and the appropriate messages display at runtime.

Some functions occur frequently and monitoring will contribute to the volume of the message log.

T00IF070D

Entering ACSECPC routine

Explanation    The security handling module is invoked.

T00IF071E

Bad parms passed to ACSECPC

Explanation    This is an Internal error. The TCP/IP system will abend.

Recommended Action    Call Customer Support

T00IF072D

Processing a sign-on

Explanation    This message displays when a userid attempts to log on.

T00IF073D

Processing a sign-off

Explanation    This message displays when a userid logs off.

T00IF074D

Processing a dataset check

Explanation    This message displays when a data set name is authorized.

T00IF075D

Placing an ACEE on the TCB

Explanation    This message displays when the ACEE monitoring option is selected.

T00IF076D

Removing an ACEE from the TCB

Explanation    This message displays when the ACEE monitoring option is selected.

T00IF077D

RACLIST directory create function in progress

Explanation    This message displays at startup when the private security directory is built.

T00IF078D

RACLIST directory delete function in progress

Explanation    This message displays at termination when the private security directory is deleted.

T00IF079D

Processing authorization call

Explanation    This message displays when authorization for a userid is verified.

T00IF080D

Result: R15 - return_code, AC#PSRC = feedback_code

Explanation    This message displays the return and feedback codes from the authorization subsystem interface.

T00IF081D

Userid = userid, Termid = termid

Explanation    This message usually follows another message and displays the userid and termid.

T00IF082D

Resource=resource_name

Explanation    This message usually follows another message and displays the resource (such as a data set name).

T00IF083D

SECACEE = address

Explanation    This is associated with ACEE monitoring and displays the SECACEE address.

T00IF084D

TCBACEE = address

Explanation    This is associated with ACEE monitoring and displays the TCBACEE address.

T00IF085D

TCBADDR =address

Explanation    This is associated with ACEE monitoring and displays the TCB address.

T00IF088D

Extracting a password

Explanation    This message displays when the password for a userid is verified.

T00IF089I

IFS timer services started

Explanation    This message is a confirmation that the timer support initialization and allocation routines have successfully completed.

T00IF090E

IFS timer services initialization failed

Explanation    The timer initialization routines failed due to storage or system related reasons.

Recommended Action    Notify Customer Support.

T00IF091E

IFS timer services allocation failed

Explanation    The timer allocation routines failed due to storage or system related reasons.

Recommended Action    Notify Customer Support.

T00IF092W

Storage usage above|below 16 meg line is at nnn%

Explanation    Storage utilization is above the alarm percentage specified in the MAXSTGPCT keyword of the IFSPARM statement in the IJTCFGxx member. Message T00IF093I will report storage utilization dropping back to acceptable levels.

Recommended Action    If the utilization drops below the threshold percentage, an occasional spike may be acceptable. If the system is constantly at this high level, a larger region allocation may be appropriate.

T00IF093I

Storage usage above|below 16 meg line is now under nnn%

Explanation    Storage utilization has dropped below the warning threshold. This message should shortly follow T00IF092W. If it does not, refer to the recommended action procedures following message T00IF092W.

T00IF094E

BLDL failed for table name; rc = ret_code

Explanation    The system BLDL function failed with return code ret_code. The module table is identified by name.

Recommended Action    One of the most common failures is missing libraries; make sure the Loadlib concatenation is correct. Otherwise, examine the return code in the IBM documentation of the BLDL support.

T00IF095E

Load failed for module name

Explanation    The system load mechanism failed for module name.

Recommended Action    Make sure the module is cataloged somewhere in the Loadlib chain.

T00IF096W

Unable to write SMF record; RC = ret_code, reason = rsn_code,     sub-type sub_type

Explanation    An attempt to write a record to the SMF data set failed. A ret_code of 12 indicates that the SMFEWTM macro failed. The SMFEWTM return code is given in rsn_code. The SMF record subtype is sub_type. If multiple sequential failures occur, Cisco IOS for S/390 will suppress all but the first message to avoid flooding the console or message logs. When a record is successfully written to the SMF data set, the internal indicator is reset and another message will be written if there is a subsequent failure.

Recommended Action    If ret_code is 12, see the IBM MVS System Management (SMF) manual for an explanation of the SMFEWTM return codes and respond appropriately. If ret_code value is other than 12, an internal error has occurred. Call Customer Support.

T00IF100I

Request complete

Explanation    The display from the ILATCH TRACE function is complete.

T00IF101E

Storage acquisition failure

Explanation    Insufficient storage to satisfy the ILATCH tracing request.

Recommended Action    If this is a transient condition, retry the tracing request.

T00IF102W

Tracing already active

Explanation    ILATCH tracing was requested earlier and is still active.

Recommended Action    None required.

T00IF103W

Tracing not active

Explanation    ILATCH trace termination did not find active ILATCH tracing.

Recommended Action    None required.

T00IF104W

The ILATCH support code is not yet operational

Explanation    ILATCH tracing is requested too early in the startup sequence.

Recommended Action    Wait until more of the system is active and retry.

T00IF105E

Entry count cannot be 0

Explanation    The number of entries must be at least 1.

Recommended Action    Correct the ENTRIES keyword and retry.

T00IF110W

Table saturated num_secs seconds ago. num_lost lost entries

Explanation    num_lost entries were lost due to a small table num_secs seconds ago.

Recommended Action    Increase the ENTRIES value and reactivate the ILATCH trace.

T00IF112I

Module      Offset   Latch@      Latch    Time     RC    Type    Count

Explanation    Header line for message T00IF113I

T00IF113I

aaaaaaaa   +bbbb     cccccccc    ddddd    eeeee    ff    gggg    hhhhh

Explanation    Data display for the ILATCH TRACE command.

Syntax Description
aaaaaaaa Name of module issuing the ILATCH request.
bbbb Hex offset into module aaaaaaaa.
cccccccc Address of the requested ILATCH block.
ddddd Number of the requested ILATCH.
eeeee Time latch held (in seconds).
ff Return code from latch request call.
gggg Either "Excl" or "Shrd" to identify the type.
hhhhh Current use counter.

T00IF114I

New logging parameters now in effect

Explanation    The operator command LOGGING was successfully executed.

T00IF115W

Error processing logging command, RC=ret_code

Explanation    The operator command LOGGING encountered parsing errors. A previous message will identify the actual error.

Recommended Action    Correct the syntax error and retry the LOGGING command.

T00IF116I

Latch Index      Requests      Suspensions      Suspend Time

Explanation    Header information for message T00IF117I. This is output from the ILATCH CONTENTION command.

T00IF117I

Latch_index      Requests      Suspensions      Suspend_time

Explanation    This message displays latches suspended due to contention.

T00IF118I

An SVC dump was suppressed by DAE. Dump title:

Explanation    A dump request was made by Cisco IOS for S/390 but the dump was suppressed by Dump Analysis and Elimination (DAE). For more information about DAE, see the IBM manual OS/390 MVS Diagnosis: Tools and Service Aids.

T00IF119W

An SVC dump was suppressed because a SYS1.DUMP dataset was not available.     Dump title:

Explanation    A dump request was made by Cisco IOS for S/390 but failed because no dump data sets were available.

Recommended Action    Clear any unneeded dump data sets.

T00IF120W

An SVC dump request failed. Return code ret_code was returned from SDUMPX.     Dump title:

Explanation    A dump request was made by Cisco IOS for S/390 but failed with return code ret_code.

Recommended Action    See the IBM manual S/30 MVS Auth Assembler Services Reference, Vol. 3 (LLA-SDU) for a description of the SDUMPX return codes. Take any appropriate action. If the return code indicates an error on the part of the caller of SDUMPX, contact Customer Support.

T00IF121I

Dump_title

Explanation    This message follows message T00IF118I, T00IF119W, or T00IF120W, and provides the title of the dump referred to in the previous message.

T00IF122E

num_suppressed msg_num Messages dropped due to storage shortage nnn mmmm

Explanation    More than a maximum number of messages were queued for processing. This happens when a large number of requests for a message are generated. An internal counter for the message number has been exceeded and the system is trying to avoid using up large amounts of storage for the message requests.

Syntax Description
num_suppressed Number of messages suppressed.
msg_num Message number of the messages that were suppressed.

T00IF123E

Incompatible Prefixes using same subsystem name

Explanation    In this release, the startup JCL for TCP, IUCV, and Trace contains a keyword PRFX=. The value for TCP is T01, the value for IUCV is T02, and the value for Trace is T03. Each also contains a keyword UN=. This keyword must have a unique value for TCP, IUCV, and Trace.

This message indicates that a subsystem (UN=) was used for one PRFX= value, then re-used for another PRFX= value without an intervening /P CLEAR or re-IPL.

Recommended Action    Restart the address space using the previous PRFX= value and issue a /P CLEAR or re-IPL the system, or change the UN= value for this address space.

T00IF124E

Restart using Prefix xxx; issue P CLEAR. Restart using current Prefix.

Explanation    See message T00IF123E, which also should have been issued. xxx is the PRFX= value that was used previously.

Recommended Action    Restart the address space using the previous PRFX= value and issue a /P CLEAR or re-IPL the system, or change the UN= value for this address space.

T00IF991E

Msg msg_num from tg_name - not found in message table

Explanation    A standardized message from the tables was requested, but no prototype was found.

Syntax Description
msg_num Message number requested from the message tables.
tg_name Name of the task group requesting the message.

Recommended Action    The message request is bypassed. Processing continues. Notify development support personnel.

T00IF992E

Msg msg_num from tg_name - invalid IMSGDEF format

Explanation    A prototype message from the tables was found to have format errors. The most likely cause is ampersands not coded in pairs, or the character after a pair of ampersands not being recognized as an editing letter-type designator.

Syntax Description
msg_num Message number requested from the message tables.
tg_name Name of the task group requesting the message.

Recommended Action    The message request is bypassed. Processing continues. Notify your development system support group or Customer Support.

T00IF993E

Abend abend occurred formatting msg msg_num for tg_name

Explanation    An ABEND occurred while issuing a message for the user. The most likely cause is bad addresses being requested for display. abend is a hexadecimal ABEND code associated with the failure.

Syntax Description
abend Hexadecimal ABEND code associated with the failure.
msg_num Message number requested from the message tables.
tg_name Name of the task group requesting the message.

Recommended Action    The message request is bypassed. Processing continues with recovery attempted. Notify your development system support group or Customer Support.

T00IF994E

Component XX not recognized

Explanation    The IMSG formatting routines encountered a message prefix with an invalid component identifier in positions 4-5.

Recommended Action    This is an internal problem. Call Customer Support.

T00IF999I

Explanation    A general message for terminating multi-line WTO sequences.

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1998 © Cisco Systems Inc.