cc/td/doc/product/software/ioss390
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

T00CFnnn - Configuration Messages

T00CFnnn - Configuration Messages

The configuration messages are the most generic group of messages and can be written by any task group as well as the Trace and IUCV address spaces. Any message that can be written by any IJT-level parsing routines are in this group. These include messages T00CF000 through T00CF999.

T00CF000 Through T00CF999

This section describes messages T00CF000 through T00CF999.

T00CF002E

Unknown configuration command - member = mem_name,     command number = cmnd_num, command = cmnd_name

Explanation    The configuration member contains an invalid statement. Initialization of APP task group or LU pool failed.

Syntax Description
mem_name Name of the configuration member.
cmnd_num Logical statement number.
cmnd_name Invalid statement.

Recommended Action    Remove the statement command from the configuration parameters and restart the APP task group. If the problem was LU pool related, correct the invalid statement, then issue an REFRESH LUPARM(mem_name) command from the console.

T00CF003E

Load of module mod_name failed

Explanation    The configuration member contains an invalid parameter.

Recommended Action    Remove the statement command from the configuration parameters and restart the APP task group. If the problem was LU pool related, correct the invalid statement, then issue an REFRESH LUPARM(mem_name) command from the console.

T00CF004E

Configuration member mem_name does not exist in SYSPARM dataset

Explanation    During initialization of the LU pool facility, the LU pool configuration member (mem_name) was not specified correctly. This message displays when the startup command script does not correctly identify the APPCFGxx or APPLUPxx configuration files, or the REFRESH LUPARM(mem_name) operator command incorrectly specifies the member name.

Recommended Action    Correctly specify the APPCFGxx and APPLUPxx configuration files and reinitialize the APP task group or issue the REFRESH LUPARM(mem_name) command with the correct APPLUPxx member.

T00CF005E

Missing required keyword = kywd - member = mem_name,     command number = cmnd_num command = cmnd_name.

Explanation    A syntax error was encountered with an APPLUPxx command statement. The LU pool facility is not activated.

Syntax Description
kywd Keyword in error.
mem_name Member name.
cmnd_num Logical number of the statement.
cmnd_name Statement containing the syntax error.

Recommended Action    Correct the statement and issue the REFRESH LUPARM(mem_name) command from the operator console.

T00CF006E

Mutually exclusive keywords = kywd - member = mem_name,
    command number = cmnd_num, command = cmnd_name.

Explanation    A syntax error was encountered in an LU pool configuration statement. The LU pool facility is not activated.

Syntax Description
kywd Keyword in error.
mem_name Member name.
cmnd_num Logical number of the statement.
cmnd_name Statement containing the error.

Recommended Action    Eliminate the conflicting keyword specification and issue the REFRESH LUPARM(mem_name) command from the operator console.

T00CF014E

Error in kywd keyword of stmt statement.

Explanation    An improper value was coded in a keyword of a statement. This error message is usually preceded by another message with more details.

Syntax Description
kywd Specified keyword.
stmt Specified statement.

Recommended Action    Correct the value in the configuration parameters and restart the APP task group.

T00CF015I

Invalid character in kywd keyword

Explanation    The keyword entered was not a valid decimal data. It must be between 0 and 9, inclusive.

T00CF016E

Unrecognized value value in keyword kywd

Explanation    A keyword was coded with a value that did not match a list of expected values.

Syntax Description
value Coded value.
kywd Specified keyword.

Recommended Action    Correct the value in the configuration parameters and restart the APP task group.

T00CF018E

Configuration statement syntax error - member mem_name,
    command cmnd_name, logical record number rec_num.

Explanation    The TSO parser detected a syntax error while processing a statement. This message is followed by message T00CF038E describing which statement is in error.

Syntax Description
mem_name Member name.
cmnd_name Failing command statement.
rec_num Logical record number of the statement containing the error.

Recommended Action    Read the Cisco IOS for S/390 Customization Guide for more information about parsing. Correct the value in the configuration parameters and restart the APP task group.

T00CF019E

value value is out of range

Explanation    The specified value is out of range.

Recommended Action    Correct the specified value and retry.

T00CF020I

driver driver has been added for device dev_name

Explanation    The named driver has been added for named device.

T00CF025E

Invalid value for subparm subparameter of statement's kywd keyword

Explanation    Value of subparm parameter is invalid or out of range.

Recommended Action    Correct the value and restart.

T00CF033W

stmnt kywd value value too large, reduced to max_value

Explanation    A value was specified that was too large. It was reduced to a lower value.

Syntax Description
stmnt Statement.
kywd Keyword.
value Value specified.
max_value Maximum value allowed.

Recommended Action    To avoid a recurrence of this message, correct the value in the configuration parameters and restart the APP task group.

T00CF034W

stmnt kywd value value too small, increased to min_value

Explanation    A value was specified that was too small. It was increased to higher value.

Syntax Description
stmnt Statement.
kywd Keyword.
value Value specified.
min_value Minimum value allowed.

Recommended Action    To avoid a recurrence of this message, correct the value in the configuration parameters and restart the APP task group.

T00CF036E

Unidentified keyword found in member(mem_name), command(cmnd_name),
    keyword(kywd), record number(rec_num)

Explanation    The TSO parser detected an unidentified keyword. This message is followed by message T00CF038E.

Syntax Description
mem_name Name of the configuration member.
cmnd_name Command statement.
kywd Unidentified keyword.
rec_num Record number of the configuration statement that contains the error

Recommended Action    Correct the value in the configuration parameters and restart the APP task group.

T00CF038E

Error statement: stmnt

Explanation    This message always follows message T00CF018E or T00CF036E. It displays the parameter and value (up to 80 characters) of the configuration statement causing the error.

Recommended Action    Take corrective action specified in the associated T00CF018E or T00CF036E message.

T00CF039E

Return code(ret_code) returned from configuration file I/O handler.

Explanation    An unexpected error was detected in the configuration file I/O handler. The code is the error/return code.

Recommended Action    Report this error to the Cisco IOS for S/390 administrator.

T00CF046E

stmnt statement # mem_rec_num in member mem_name exceeds 64K

Explanation    The parameter text in a statement exceeds 65,586 characters. All further configuration statement processing is halted.

Syntax Description
stmnt Specified statement.
mem_rec_num Configuration member record number.
mem_name Configuration member.

Recommended Action    Correct the value in the configuration parameters and restart the APP task group.

T00CF066W

stmnt kywd value class is invalid; using oclass

Explanation    Keyword kywd value class is invalid. The previous value oclass will be used.

T00CF067W

stmnt kywd invalid subfield field - bypassing

Explanation    Keyword kywd of statement stmnt contains invalid subfield of field.

T00CF100W

Component component not recognized in LOGGING statement

Explanation    The component specified by component is unknown in the LOGGING statement.

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1998 © Cisco Systems Inc.