VFC Management Overview

Voice feaure cards (VFCs) for the Cisco AS5300 come with a single bundled image of VCWare stored in VFC Flash memory. Table 19 shows the extension types defined for these embedded firmware files.


Table 19: VFC Firmware Extensions
Firmware Filenames Description

VCWare

vcw-vfc-*

Latest version of VCWare stores in Flash memory, including:

  • Datapath engine

  • Message dispatcher

  • DSP manager

  • VC manager

  • Process scheduler

DSPWare

btl-vfc-*

DSP bootloader

cor-vfc-*

Core operating system and initialization

bas-vfc-*

Base voice

cdc-*-*

Voice codec files

fax-vfc-*

Fax relay files

DSPWare is stored as a compressed file within VCWare; you must unbundle VCWare to install DSPWare into Flash memory. During the unbundling process, two default lists (the default file list and the capability list) are automatically created, populated with default files from that version of VCWare, and stored in VFC Flash memory. The default file list contains the filenames indicating which files are initially loaded into DSP upon bootup. The capability list defines the set of codecs that can be negotiated for a voice call.

VFC Management Task List

VFC management enables you to add versions of VCWare to Flash memory (download and unbundle files), erase files contained in Flash memory, add files to the default file list and capability list, and delete files from the default file lists and capability lists. These tasks are described in the following sections:

Downloading VCWare

To download software to your VFC, perform the following tasks:

Determining the Number of VFCs

To determine the number of installed VFCs and their location, use the following command in privileged EXEC mode:

Command Purpose
Router# show vfc slot directory

Determines the number of installed VFCs and their location.

For each VFC identified and located, perform the tasks described in the following sections to upgrade system software on that VFC.

Identifying the VFC Mode

To identify the mode (whether VCWare or ROM Monitor), use the following command in privileged EXEC mode:

Command Purpose
Router# show vfc slot board

Determines whether your VFC is operating in VCWare mode or ROM Monitor mode.

If the mode is VCWare, the VFC status will be "VCWARE running." If the mode is ROM Monitor, the VFC status will be "ROMMON."

Downloading Software (VCWare Mode)

To download VFC software to the VFC while the VFC is in VCWare mode, use the following commands beginning in privileged EXEC mode:

Command Purpose

Step1

Router# erase vfc slot

Erases the Flash memory.

Step2

Router# show vfc slot directory

Verifies that the VFC Flash memory is indeed empty.

Step3

Router# copy tftp vfc

or

Router# copy flash vfc

Downloads the VCWare from a TFTPBoot server into VFC Flash memory.

or

Downloads the VCWare from the VFC motherboard into VFC Flash memory.

Step4

Router# clear vfc slot

Reboots the VFC.

Step5

Router# show vfc slot board

Checks whether the VFC is back up in VCWare mode.

Step6

Router# show vfc slot directory

Verifies that VCWare is in the VFC Flash.

Step7

Router# unbundle vfc slot

Unbundles the DSPWare from the VCWare and configures the default file list and the capability list.

Step8

Router# show vfc slot directory

Verifies that the DSPWare has been unbundled.

Step9

Router# show vfc slot default-list

Verifies that the default file list has been populated.

Step10

Router# show vfc slot cap-list

Verifies that the capability list has been populated.

After you have completed the preceding tasks, reboot the Cisco AS5300 for these changes to take effect.


NoteIf the VFC ROM is version 1.1, the image name must end in ".VCW." If the VFC ROM is version 1.2, the image name must start with "vcv-."

Downloading Software (ROM Monitor Mode)

To download VFC software to the VFC while the VFC is in ROM Monitor mode, use the following commands beginning in privileged EXEC mode:

Command Purpose

Step1

Router# clear vfc slot purge

Erases the VFC Flash memory.

Step2

Router# copy tftp vfc

or

Router# copy flash vfc

Downloads the VCWare from a TFTP server into VFC Flash memory.

or

Downloads the VCWare from the VFC motherboard into VFC Flash memory.

Step3

Router# clear vfc slot

Reboots the VFC.

Step4

Router# show vfc slot board

Checks whether the VFC is back up in VCWare mode.

Step5

Router# show vfc slot directory

Verifies that VCWare is in the VFC Flash.

Step6

Router# unbundle vfc slot

Unbundles the DSPWare from the VCWare and configures the default file list and the capability list.

Step7

Router# show vfc slot directory

Verifies that the DSPWare has been unbundled.

Step8

Router# show vfc slot default-list

Verifies that the default file list has been populated.

Step9

Router# show vfc slot cap-list

Verifies that the capability list has been populated.

After you have completed the preceding tasks, reboot the Cisco AS5300 for these changes to take effect.


NoteThe image name must start with "vcw-."

Copying Flash Files to the VFC

As mentioned, each VFC comes with a single bundled image of VCWare stored in Flash memory. VoIP for the Cisco AS5300 offers two different ways to copy new versions of VCWare to the VFC Flash memory: either by downloading the image from the AS5300 motherboard or by downloading the VCWare from a TFTP server.

Downloading VCWare to the VFC from the AS5300 Motherboard

To download the VCWare file from the AS5300 motherboard to VFC Flash memory, use the following command in privileged EXEC mode:

Command Purpose
Router# copy flash vfc

Downloads (copies) the Flash file from the AS5300 motherboard to the Flash memory on the VFC.

Downloading VCWare to the VFC from a TFTP Server

To download the latest version of VCWare from a TFTP server, make sure that the file is stored on the TFTP server. If you have a copy of the current version of VCWare on disk, you must store that image on a TFTP server before you can download the file to VFC memory.

To copy the Flash file from a TFTP server, use the following command in privileged EXEC mode:

Command Purpose
Router# copy tftp vfc

Downloads (copies) the Flash file from a TFTP server to the Flash memory on the VFC.

Unbundling VCWare

VCWare needs to be unbundled for DSPWare to be loaded in Flash memory and the two necessary default lists (default file list and capability list) created and populated with the appropriate default files for that version of DSPWare. Table 20 shows the files associated with each firmware file.


Table20: VFC Firmware Filenames
Firmware Filenames

VCWare

vcw-vfc-mz.0.15.bin

DSPWare Initialization and Static Files

btl-vfc-1.0.14.0.bin
cor-vfc-1.0.14.0.bin
jbc-vfc-1.0.14.0.bin

DSPWare Overlay Files

bas-vfc-1.0.14.0.bin
cdc-g711-1.0.14.0.bin
cdc-g729-1.0.14.0.bin
fax-vfc-1.0.14.0.bin

To unbundle the current running image of VCWare, use the following command in privileged EXEC mode:

Command Purpose
Router# unbundle vfc slot

Unbundles the current image of VCWare.

Adding Files to the Default File List

When you unbundle VCWare, the default file list is automatically created and populated with the default files for that version of VCWare. The default file list indicates which files are initially loaded into DSP upon bootup. The following example shows the output from the show vfc def command, which displays the contents of the default file list:

router# show vfc 1 def
 
Default List for VFC in slot 1:
1. btl-vfc-1.0.13.0.bin
2. cor-vfc-1.0.1.bin
3. bas-vfc-1.0.1.bin
4. cdc-g729-1.0.1.bin
5. fax-vfc-1.0.1.bin
6. jbc-vfc-1.0.13.0.bin
 

Under most circumstances, these default files should be sufficient. If you need to, you can add a file (from those stored in VFC Flash memory) to the default file list or replace an existing file from the default file list. When you add a specific file to the default file list, it replaces the existing default for that extension type.

To select a file to be added to the default file list, use the following command in global configuration mode:

Command Purpose
Router(config)# default-file vfc

Selects a file stored in the Flash memory to be added to the default file list.

Adding Codecs to the Capability List

The capability list defines the set of codecs that can be negotiated for a voice call. Like the default file list, the capability list is created and populated when VCWare is unbundled and DSPWare added to VFC Flash memory. The following example shows the output from the show vfc cap command, which displays the contents of the capability list:

router# show vfc 1 cap
 
Capability List for VFC in slot 1:
1. fax-vfc-1.0.1.bin
2. bas-vfc-1.0.1.bin
3. cdc-g729-1.0.1.bin
4. cdc-g711-1.0.1.bin
5. cdc-g726-1.0.1.bin
6. cdc-g728-1.0.1.bin
7. cdc-gsmfr-1.0.1.bin
 

VFC management lets you add codec files to the capability list to meet the needs of your specific telephony network.


NoteThe capability list does not indicate codec preference; it simply reports the codecs that are available. The session application decides which codec to use.

To add a codec overlay file to the capability list, use the following command in global configuration mode:

Command Purpose
Router(config)# cap-list file-name vfc slot-number

Selects a codec overlay file to be added to the capability list.

Deleting Files from VFC Flash Memory

In some instances, you might need to delete a file from the default file list or the capability list or you might need to revert to a previous version of VCWare stored in Flash memory. To delete a file, you must identify and delete the file from VFC Flash memory. Deleting a file from Flash memory removes the file from the default file list and capability list (if the deleted file is included on those lists).

To delete a file from VFC Flash memory, use the following command in privileged EXEC mode

:
Command Purpose
Router# delete file-name vfc slot

Deletes the specified file from VFC Flash memory.

Erasing the VFC Flash Memory

When you upgrade to a later version of VCWare, the new files are stored in VFC Flash, along with those already stored in VFC Flash memory---the new files do not overwrite existing files. Consequently, you will eventually need to erase the contents of VFC Flash memory to free VFC Flash memory space. Erasing VFC Flash memory removes the entire contents stored in Flash memory, including the default file list and the capability list.

To erase the Flash memory of a specific VFC, use the following command in privileged EXEC mode:

Command Purpose
Router# erase vfc slot

Erases the Flash memory on the VFC.

For more information about VFC management commands, refer to the Cisco IOS Multiservice Applications Command Reference publication.