M32X Basic Rate Interface (BRI) trunk card error messages
Explanation The download of the internal microcode to the M32X failed to checksum correctly. This message usually indicates a M32X hardware failure.
Recommended Action Perform a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The M32X trunk card failed. It could not download its operational microcode.
Recommended Action Perform a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The M32X trunk card did not complete hardware initialization.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The M32X has not responded to a message within a specified time.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The M32X trunk card has failed. It could not download its operational microcode.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A hardware error occurred involving the PCI interface for an M32X trunk card
Recommended Action If it is an M32X trunk card then this is error message is caused by a malfunction. This message may also be caused by another PCI device being mistaken for an M32X. Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The M32X trunk card did not respond when commanded to download its operational microcode.
Recommended Action Perform a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software or hardware error occurred in the M32X trunk card.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The interface entered or exited a remote loopback.
Recommended Action No action is required.
Explanation A software or hardware error occurred. The M32X trunk card is not responding to commands used to initialize it.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software or hardware error occurred. The M32X trunk card did not respond to a request to disable an interface.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An output packet was detected that was smaller than the minimum allowable datagram size. An error in another driver or an error in the system software probably triggered this error message.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
ChipCom mailbox error messages
Explanation A hardware or software error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The data received from an ECHO_RESPONSE protocol data unit (PDU) did not match the original data provided in the ECHO_REQUEST. Usually, this message is seen during initialization, and indicates a catastrophic failure of the mailbox interface. See MAILBOX-3-INITFAIL for more information.
Recommended Action Confirm the router module installation. Ensure that the software revision on the management module and the router module carrier card is up-to-date. If the error persists, call your technical support representative for assistance.
Explanation The protocol data unit (PDU) received was valid, but the type is not supported in the current software implementation. It will be ignored.
Recommended Action This is an informational message only. No action is required.
Explanation A catastrophic failure involving the initialization of the administrative mailbox occurred. The mailbox will be taken offline and remain in that state until a router module reset, or a system reload, occurs. At that time, initialization will again be attempted. Note that the functionality of the router (its ability to receive and forward packets) is not affected by this error.
Recommended Action Confirm the router module installation. Ensure that the software revision on the management module and the router module carrier card is up-to-date. If the error persists, call your technical support representative for assistance.
Explanation This message is generated after a router reload to indicate the mailbox was successfully initialized.
Recommended Action This is an informational message only. No action is required.
Explanation This message header is paired with general debugging messages used to provide information about the functionality of the mailbox. To enable mailbox debugging, issue the debug mailbox command.
Recommended Action This is an advisory message only. No action is required.
Explanation An ECHO_RESPONSE was not received in the appropriate time after the generation of an ECHO_REQUEST. This failure only occurs during mailbox initialization, and indicates a problem between the communication path of the router module and its carrier card.
Recommended Action Confirm the router module installation. Ensure that the software revision on the management module and the router module carrier card is up-to-date. If the error persists, call your technical support representative for assistance.
Explanation This message is generated when an attempt is made by the management module to communicate with an offline mailbox. When it appears, it indicates a problem exists between the perceived state of the mailbox from the router's side versus the management module's side.
Recommended Action Issue a system-wide reset on the management module. If the error persists, call your technical support representative for assistance.
Explanation This message is generated only when mailbox debugging is enabled. It provides information about the state of each incoming or outgoing mailbox.
Recommended Action This is an advisory message only. No action is required.
Explanation This message is generated only when mailbox debugging is enabled. It provides very low-level information about the incoming mailbox data stream.
Recommended Action This is an advisory message only. No action is required.
Explanation A timeout occurred while sending or receiving the characters of a protocol data unit (PDU). The entire PDU will be ignored.
Recommended Action This is an informational message only. No action is required
Explanation This message is generated only when mailbox debugging is enabled. It provides very low-level information about the outgoing mailbox data stream.
Recommended Action This is an advisory message only. No action is required.
Multi-BRI port module error messages
Explanation The MBRI network module failed to complete initialization.
Recommended Action Ensure that there is sufficient memory available in the router. If you continue to get this message, copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The MBRI network module failed to complete initialization.
Recommended Action Ensure that there is sufficient memory available in the router. If you continue to get this message, copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The network module hardware reports that a non-MBRI port module was detected.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The requested operation could not be accomplished because a global pool of timer elements was empty. This may be caused by a transient condition.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The MBRI driver detected an invalid Layer 1 condition.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Maintenance bus error messages
Explanation The slot must see the fabric clock from at least one of the CSC cards. If just one CSC is present, the card must sync to that clock to operate on the fabric. If two CSCs are present, the following cases are possible:
Recommended Action Verify that the card is seated correctly. Try to reset or power cycle the card. Run diagnostics for the card if possible. If the condition recurs, copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation The primary clock for the system had to be changed because of frame sync errors detected in the specified slot. The switch will be done under the conditions described below. Note that when the switch to a new clock is made, the RP/CSC combination is not known to have failed previously. The switch is made when
Recommended Action This is a hardware failure. Run diagnostics on the specified card and the original primary CSC if possible. If fabric errors persist, remove the CSC, copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation The slot clock changed its redundancy state. If the card lost its redundancy state, it can still operate with the other clock. This problem may be localized to the line card or may be a global event caused by a malfunctioning CSC card. In the latter case, all line cards will show this condition.
Recommended Action Verify that the other clock is seen correctly using the show controller clock command.
Explanation Failed to lock fabric clocks. This implies that Clock/Scheduler redundancy cannot be achieved in this configuration. If this failure occurred during the boot process, the system primary clock will be chosen by a majority rule (that is, the primary clock will be the clock synched to by the majority of the cards). If this failure occurred during an OIR event, the initial primary clock will be maintained. Cards that do not sync to the selected primary clock will not operate over the fabric. Use the show controller clock command to check the clock configuration for the individual cards.
Recommended Action This is a hardware failure. Replace or re-insert the CSC cards and try again. If the condition recurs, copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation There are two CSC cards in the system but they cannot sync to each other. Therefore, they are configured as non-redundant.
Recommended Action Copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation Slots 16 through 17 can contain only CSC cards.
Recommended Action Remove non-CSC cards from specified slot. If you are sure it is a CSC card, verify that the EEPROM is programmed correctly. Use the show diags details command to read the EEPROM contents and report it to your technical support representative.
Explanation The CSC card represents a different chassis type than programmed into the chassis backplane NVRAM.
Recommended Action Contact your technical support representative.
Explanation This is the list of discovered cards.
Recommended Action No action is required.
Explanation The specified image could not be downloaded to the card. The card will be automatically reset and the download retried.
Recommended Action Try resetting or re-inserting the card. You may also try power cycling the card. If the condition recurs, copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation The specified module is an old version.
Recommended Action Obtain the new version from your technical support representative.
Explanation Failed to read the EEPROM contents in the specified slot.
Recommended Action Check other error messages that follow.
Explanation The Switch Fabric is configured as mentioned.
Recommended Action No action is required.
Explanation Errors have been detected by the line card/RP from the indicated switch card. However, because of the lack of redundancy in the fabric, this card cannot be removed.
Recommended Action Replace this switch card and contact your technical support representative.
Explanation Check the previous set of error messages. At least one CSC card must be detected and configured.
Recommended Action Insert a CSC card. If a CSC card is present, verify it is seated correctly and then power cycle or reboot the GSR. If the condition persists, copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation The FIA was configured as specified.
Recommended Action No action is required.
Explanation The FIA has been halted.
Recommended Action No action is required.
Explanation An MBUS message was sent and a response was received (or at least it did not time out), but when the scheduler was asked for the message, an error occurred.
Recommended Action Submit a bug with as much information as possible, including the console output at the time of the error.
Explanation The GRP must see Frame Syncs every 1.04 ms.
Recommended Action Power cycle the GSR. If the condition recurs, contact your technical support representative.
Explanation This message indicates GRP Master/Slave status information.
Recommended Action No action is required.
Explanation The ROM monitor reports that the Cisco IOS software on the line card crashed.
Recommended Action The line card is automatically reset by the GRP. If the problem recurs, try re-inserting the line card or run diagnostics on the line card.
Explanation The specified module could not be successfully launched.
Recommended Action Reset the line card. If the condition recurs, copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation The fabric configurations for the cards are assigned by the master GRP. The configurations may be temporarily different during reconfiguration of fabric (such as insertion, removal, or malfunction of switch cards) because the GRP has changed its configuration but has not yet notified the line card. A line card may modify its FIA configuration without changing its bandwidth mode. In addition, it is possible for the line card to have a different primary clock if there are two CSCs configured as redundant.
Recommended Action No action is required.
Explanation The model type programmed into the backplane NVRAM is invalid. The CSCs in the chassis also contained invalid types.
Recommended Action Contact your technical support representative.
Explanation The software called send_mbus_msg with a length greater than 254. This is a software defect.
Recommended Action Submit a bug with as much information as possible, including the console output at the time of the error.
Explanation No cards were detected. At least the GRP must be discovered via the MBUS.
Recommended Action Power cycle the GSR and retry.
Explanation At least one CSC card must be present in the system.
Recommended Action If necessary, insert a CSC card in slot 16 or 17 and reboot the system.
Explanation No fabric card was detected in the system.
Recommended Action If necessary, insert a CSC card in slot 16 or 17 and reboot the system.
Explanation The slot must see the fabric clock from at least one of the CSC cards.
Recommended Action Try resetting or re-inserting the card. You may also try power cycling the card. If the condition recurs, copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation The image was missing in the bundle linked with this Cisco IOS image. The image is required for downloading. This usually represents a build problem.
Recommended Action Contact your technical support representative.
Explanation The call to process_create failed when creating the process used to handle the timers for the user commands to write to the LED's. The only effect of this failure is that the user commands to write LED messages will not work, but there may be more serious problems if Cisco IOS software is having trouble creating processes during initialization.
Recommended Action Reboot the router. If the condition recurs and is isolated to just this process, ignore the problem and continue.
Explanation An insertion or removal event was detected.
Recommended Action No action is required.
Explanation The register in the specified slot could not be read.
Recommended Action Check other error messages that follow.
Explanation A register that was not being monitored has indicated a status change. This is probably a software error.
Recommended Action If the condition recurs, contact your technical support representative.
Explanation The specified registry could not be created. This is a catastrophic error for this feature.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation Errors have been detected by the line card/RP from the indicated switch card. This card has been removed from the fabric configuration and has been powered down.
Recommended Action Remove or replace this switch card and contact your technical support representative.
Explanation The GRP was not discovered via the MBUS.
Recommended Action Power cycle the GSR and retry.
Explanation Slots 18 through 20 can contain only SFC cards.
Recommended Action Remove non-SFC cards from the specified slot. If you are sure it is a SFC card, verify that the EEPROM is programmed correctly. Use the show diags details command to read the EEPROM contents and report it to your technical support representative.
Explanation The indicated CSC card was to be designated as the secondary clock. It failed to phase lock with the primary clock. Therefor, they are not configured in redundant mode.
Recommended Action Copy the error message exactly as it appears (as well as previous error messages) and report it to your technical support representative.
Explanation The selected clock has changed on the card. If the slot was configured with redundant clock, then this is the new clock for this card. It should continue functioning in non-redundant mode. If the redundancy mode is maintained, the clock should not switch (unless there is an external user specification or command forcing it to do so).
Recommended Action No action is required.
Explanation An MBUS message was sent and timed out while waiting for a response. This error could be caused by possible hardware or software problems. Some of the hardware that could cause this problem are the MBUS module on the RP, the slot it was sending the message to, or the GRP.
Recommended Action For an occasional problem, just ignore the message. For a persistent problem or one involving lots of timeouts, you should send e-mail to the appropriate cs- mailing list. If the problem is always associated with a single slot or MBUS device, Cisco recommends that you replace the MBUS module and/or the whole FRU (such as line card or power supply). If the problem is associated with many different slots or MBUS devices, it is recommended that you replace the RP MBUS module and/or the whole GRP. If replacing hardware does not solve the problem, submit a bug report with as much information as possible, including the console output at the time of the error.
Explanation The mode set does not need the specified SFC. It is ignored for the configuration; removing it will make no difference to system performance.
Recommended Action Verify that this is indeed the case (that is, verify that the bandwidth mode of the fabric is the expected bandwidth). No action is usually required.
Explanation When sending an MBUS message and waiting for a response, the process wake up reason is changed while waiting for the response. There was an error getting the current wake up reason for the process. This is caused by an error in the scheduler or some other software bug in the MBUS code.
Recommended Action For any occurrence of this problem, contact your support representative. Include the exact message and the traceback that accompanies it. If the problem is persistent or happens frequently, reload the router.
MBUS system error messages
Explanation Failed to enqueue a message from the interrupt for process level software. The message will be dropped. This error message points to a potential problem in the mbus process level message handling. The error can occur if there are problems with the mbus process specifically or if there are general software process related issues. It may also occur if the mbus process is not scheduled for extended periods of time and there is heavy MBUS traffic.
Recommended Action If this is a persistent problem, either the mbus process is dead or there are other software related problems. Consider rebooting the GRP if possible.
Explanation A message from a slot exceeded the maximum message size and will be dropped. This should not occur during normal operations.
Recommended Action Verify the health of MBUS using the show mbus counters and show mbus can-error commands. If a particular card shows errors and this condition persists, try reloading the card if possible. The error counts in the show mbus commands can be cleared by using the clear mbus-statistics command.
Explanation An attempt was made to send a message on an invalid MBUS channel.
Recommended Action Submit a bug with as much information as possible, including the console output at the time of the error.
Explanation An attempt was made to send a message with a length greater than 254.
Recommended Action Submit a bug with as much information as possible, including the console output at the time of the error.
Explanation A message from the slot was dropped since there were no MBUS buffers available. Either the messages are coming too fast or the process level message handling is not draining messages quickly enough.
Recommended Action This condition should correct itself. Check if the GRP is being inundated by messages from the chassis. If the condition persists, consider rebooting the GRP.
Explanation An MBUS channel could not be allocated for sending messages. There is either very heavy MBUS traffic or there is a hardware problem. If there is temporarily heavy traffic, the condition will clear itself. In the case of hardware errors, either the MBUS agent has died or the hardware interface to the mailbox is not draining messages. Resetting the processor (including the agent) may clear the problem. If the problem persists, the card probably has hardware problems and needs diagnosis.
Recommended Action Power cycle the card. If the problem persists, check for hardware problems.
Explanation A reassembly error was detected for the given slot/stream combination. Either the slot/stream combination was incorrect (so that it gave an invalid reassembly buffer index) or the first or last packets were lost. The message will be dropped, which may cause errors for the application running over MBUS.
Recommended Action This condition should correct itself. No action is required.
Explanation The specified registry could not be created. This is a catastrophic error for this feature.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation An incorrect sequence number was detected in a multi-packet message. This could happen if the source packetized the message incorrectly or more likely, one or more packets got dropped.
Recommended Action Check if there is excessive MBUS activity, copious printing from a line card and so forth. Issue the command show mbus counters to obtain lost message count.
Explanation Failed to receive a response from a mbus request. This could be either a request for a EEPROM field or a register read.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation A message could not be transmitted because all the transmit buffers were full for over 10 seconds. This may be a temporary problem if there is heavy MBUS traffic. Otherwise, it is probably a hardware problem. Either the mbus agent is not responding or the hardware interface is not generating interrupts.
Recommended Action If this is a persistent problem, power cycle the card. If the problem still continues, it is likely to be a hardware problem and needs diagnosis.
Explanation An unexpected response to a read register or read EEPROM was received.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Modem ISDN Channel Aggregation modem error messages
Explanation The block information that is necessary to download modem firmware was missing for the indicated firmware version.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Run-time checks for modem health determined that the indicated modem was no longer functional because of a hardware or software error.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The modem module in the indicated socket is bad, possibly because the serial EEPROM on the module is misprogrammed.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A message was received from the indicated modem that had an illegal opcode.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An attempt was made to transmit a message to the indicated modem that had an illegal opcode.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software error occurred, resulting in an unexpected packet being set up for transmission and then the packet was dropped.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software error occurred on the modem firmware executing on the indicated modem module.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The indicated modem module was successfully initialized.
Recommended Action No action is required.
Explanation The modem state machine received an unexpected event while in the state indicated by the error message.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A message sent to the indicated modem was rejected.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The software structures that are used to drive the DMA engines were temporarily exhausted while attempting the task indicated in the error message; the task was aborted as a result.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software structure was found in an unexpected state during run-time for the indicated modem.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The software structures that are used to receive and transmit messages from the MICA modems were temporarily exhausted.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software structure was found in an unexpected state during run-time for the indicated modem.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software structure was found in an unexpected state during run-time for the indicated modem.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A hardware error occurred involving the PCI interface chip.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software structure was found in an unexpected state during run-time for the indicated modem.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Modem firmware of the indicated version, bundled into the modem card image, did not pass the sanity tests used to verify a firmware image.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The diagnostic message that is expected back from a MICA modem after successful download and initialization of the modem firmware was never received.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The indicated modem module suffered a run-time error and had to be reset and an attempt is now being made to restart the modem module.
Recommended Action No action is required.
Explanation The packet to be transmitted needed more descriptors than are available on the transmit ring, and the packet was dropped.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
PCI MC68840 FDDI port adapter error messages
Explanation The number of interfaces found was not what was expected. This could indicate a hardware failure.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The FDDI driver failed to initialize.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The requested device or port is not supported as a FDDI interface.
Recommended Action No action is required.
Explanation This message indicates an internal software inconsistency.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
MCOM integrated modem network modules error messages
Explanation The integrated modem network module hardware may be bad.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The integrated modem network module hardware may be bad.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The integrated modem network module hardware may be bad.
Recommended Action Power down, reinsert the network module and reboot. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The integrated modem network module hardware may be bad.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The integrated modem network module hardware may be bad.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The integrated modem hardware may be bad.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The router does not have enough memory to perform the function.
Recommended Action Ensure that there is sufficient memory available in the router. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A critical error occurred and the device driver unsuccessfully attempted to reset the modem.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The network module is not compatible with the current platform that it is plugged into.
Recommended Action Power down, remove the network module and reboot.
MK5025 serial controller error messages
Explanation An internal software error occurred.
Recommended Action If either of these messages recur, call your technical support representative for assistance.
Explanation The hardware failed to initialize correctly.
Recommended Action Repair or replace the controller.
Explanation The hardware failed to initialize correctly.
Recommended Action Repair or replace the controller.
Explanation The hardware failed to initialize correctly.
Recommended Action Repair or replace the controller.
Explanation Too many modem control interrupts have been received. The port was disabled to prevent excessive use of the CPU.
Recommended Action Check the cable on the serial port.
Explanation A network serial interface detected a hardware problem.
Recommended Action Repair or replace the controller.
Explanation The requested operation could not be accomplished because of a low-memory condition.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation An internal software error occurred.
Recommended Action If either of these messages recur, call your technical support representative for assistance.
Explanation A network serial interface detected a hardware problem.
Recommended Action Repair or replace the controller.
Explanation A network serial interface detected a hardware problem.
Recommended Action Repair or replace the controller.
Explanation A network serial interface detected a hardware problem.
Recommended Action Repair or replace the controller.
Explanation A network serial interface detected a hardware problem.
Recommended Action Repair or replace the controller.
Integrated modem network module error messages
Explanation The integrated modem Network Module hardware may be bad.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The integrated modem override file does not contain valid images.
Recommended Action The integrated modem Network Module will be loaded with the default software images. Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The integrated modem override file is not compatible with the version of integrated modem hardware.
Recommended Action The integrated modem Network Module will be loaded with the default software images. This override file can only be used with specified Network Module hardware versions.
Explanation The integrated modem override file is not compatible with the version of integrated modem hardware.
Recommended Action The integrated modem Network Module will be loaded with the default software images. This override file can only be used with specified Network Module hardware versions.
Explanation The integrated modem override file is not compatible with the Cisco IOS release running on this router.
Recommended Action The integrated modem Network Module will be loaded with the default software images. This override file can only be used with specified Cisco IOS releases.
Explanation The integrated modem override file is not compatible with the Cisco IOS release running on this router.
Recommended Action The integrated modem Network Module will be loaded with the default software images. If you wish to use this modem override image file, you must upgrade to the specified Cisco IOS release.
Explanation The integrated modem override file does not contain valid firmware images.
Recommended Action The integrated modem Network Module will be loaded with the default software images. Copy the error message exactly as it appears, and report it to your technical support representative.
Router shelf modem management error messages
Explanation This is a tracing message that indicates a back-to-back test failed between the two specified MICA modems.
Recommended Action Perform more back-to-back tests by pairing the failed modems with other modems to determine which modem is bad. Check the failed modems again after performing a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A back-to-back test connection has been made between the selected modems. The test is still in progress.
Recommended Action No action is required.
Explanation This is a tracing message that indicates an automatic back-to-back test was initiated by the specified MICA modem.
Recommended Action This is a debug message only. No action is required.
Explanation The reported modems have passed the back-to-back test without any errors.
Recommended Action No action is required.
Explanation The modem management facility received an unrecognized event.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software or hardware problem was detected on a modem. The specific modem and reason are listed in the message.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The two modems reported in the message failed a back-to-back test. At least one of them has failed.
Recommended Action Perform more back-to-back tests by pairing the failed modems with other modems to determine which modem is bad. Check the failed modems again after performing a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The fast-answer configuration conflicts with the country setting. The country was given priority and fast-answer was disabled.
Recommended Action No action is required.
Explanation The specified modem failed to download its internal microcode.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The specified modem succeeded downloading its internal microcode.
Recommended Action No action is required.
Explanation The specified modem has begun downloading its internal microcode.
Recommended Action No action is required.
Explanation Tests on the specified modem were successful.
Recommended Action No action is required.
Explanation The direct-connect (DC) session did not have enough time to complete.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The modem management subsystem's status-polling state machine received an undefined event for or from the specified modem.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The modem management subsystem's status-polling state machine for the specified modem entered an undefined state.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Router shelf modem history/tracing messages
Explanation This is a tracing message indicating a reply to a control message was received.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating the number of the ISDN line receiving a call.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating the number of an incoming ISDN caller.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a dialed ISDN number.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a dynamic event reported by the specified MICA modem.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating an end-connection event from the specified MICA modem.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a lead event reported by the specified MICA modem.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating an out-of-service event from the specified MICA modem.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a successful startup of the specified MICA modem.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a state event reported by the specified MICA modem.
Recommended Action This is debug message only. No action is required.
Explanation This is a tracing message indicating a static event reported by the specified MICA modem.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a status event reported by the specified MICA modem.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a change in analog signal status.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating caller ID data received.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating establishment of a connection.
Recommended Action This is a debug message only. No action is required.
Explanation This is a continuation of the connection state tracing message.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a connection state change.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a change in the DTR signal.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating end-of-connection status.
Recommended Action This is a debug message only. No action is required.
Explanation This is a continuation of the end-of-transmission status message.
Recommended Action This is a debug message only. No action is required.
Explanation This is another continuation of the end-of-transmission status message.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a polling protocol error.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a polling event was lost.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a change in data activity status.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a modem state change.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating that no response was received to a poll.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a phone number being dialed.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating status of a call in progress.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating RS232 events.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating transmit and receive events.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating that the modem event history contained an unrecognized event. One or more events may be missing from the trace.
Recommended Action This message could be caused by insufficient space to store the modem history. If these events are desirable, a possible remedy is to shorten the number of events recorded between history dumps. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation This is a tracing message indicating successful startup of the specified modem.
Recommended Action This is a debug message only. No action is required.
Explanation This is the initial message for the trace of the specified modem. The modem's stored trace messages will follow.
Recommended Action This is a debug message only. No action is required.
Explanation This is a tracing message indicating a formatting error in the modem event history. One or more events may be missing from the trace.
Recommended Action This is a debug message only. No action is required.
Modem NVRAM error message
Explanation This message type is created for all messages that have simple ASCII text and do not take parameters. The message indicates what the problem is.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
VIP Multi-channel Port Adapter error messages
Explanation The download of the internal microcode to the MPA68360 failed to checksum correctly. This usually indicates a hardware failure of the MPA68360.
Recommended Action Perform a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The MPA68360 interface failed. It could not download its operational microcode.
Recommended Action Perform a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The MPA68360 failed to complete hardware initialization.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The MPA68360 has not responded to a message within a specified time.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The MPA68360 failed. It could not download its operational microcode.
Recommended Action Perform a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The MPA68360 hardware failed. A non-MPA68360 device pointed at the software for the MPA68360 serial.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The MPA68360 did not respond when commanded to download its operational microcode.
Recommended Action Perform a power cycle. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software or hardware error occurred in the MPA68360 interface.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software or hardware error occurred. The MPA68360 is not responding to commands used to initialize it.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software or hardware error occurred. The MPA68360 failed to respond to a request to disable an interface.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An output packet was detected that was smaller than the minimum allowable datagram size. An error in another driver or an error in the system software probably triggered this error message.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Multiprotocol-over-ATM error messages
Explanation A software error occurred in the multiprotocol-over-ATM client (MPC) software.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation This is a multiprotocol-over-ATM client (MPC) status or information message
Recommended Action No action is required.
Explanation This is a non-fatal warning from the multiprotocol-over-ATM client (MPC) software---probably the result of an incorrect configuration or operator command. Details about the warning are included in the message.
Recommended Action Try to determine if a configuration or operator error caused this warning. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software error occurred in the multiprotocol-over-ATM subsystem.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A software error occurred in the multiprotocol-over-ATM server (MPS) software.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation This is a multiprotocol-over-ATM server (MPS) status or information message
Recommended Action No action is required.
Explanation This is a non-fatal warning from the multiprotocol-over-ATM server (MPS) software---probably the result of an incorrect configuration or operator command. Another possible but less likely cause could be an internal software error.
Recommended Action Try to determine if a configuration or operator error caused this warning. If the message recurs, copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A multiprotocol-over-ATM entity was brought up or down.
Recommended Action This is only a status message. No action is required.
Multicast route error messages
Explanation An error in the multicast routing table occurred. A route could not be deleted from the routing table.
Recommended Action Execute a clear ip mroute command. Determine whether the router is low on memory. If the message recurs, copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation Insufficient memory is available to initialize the IP multicast routing table.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An error in the multicast routing table occurred. A route could not be inserted in to the routing table.
Recommended Action Execute a clear ip mroute command. Determine whether the router is low on memory. If the message recurs, copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Mx serial ASIC error messages
Explanation A user has changed the DSU bandwidth using DS3 remote management commands. This will not change the user configured DSU bandwidth.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The Mx serial hardware failed. Some interfaces on the board failed to come up.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The Mx serial hardware failed. It could not download its operational microcode.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The Mx serial firmware failed.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The Mx serial port adapter failed to complete hardware initialization.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The Mx serial hardware failed. A non-Mx serial device pointed at the Mx serial software.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation A software or hardware error occurred. The Mx serial driver detected that the transmit ring is in an inconsistent and unrecoverable state.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation A software or hardware error occurred. The Mx serial interface is not responding to commands used to initialize it.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The Mx serial port adapter failed to respond to a request to disable an interface.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Network clock synchronization error messages
Explanation This warning message indicates a change in the clock source.
Recommended Action No action is required.
Explanation This warning message indicates that the internal network clock will be used.
Recommended Action No action is required.
Explanation The clock source has failed.
Recommended Action If an alternate source is available, it will be used.
Next Hop Resolution Protocol error messages
Explanation An error indication packet was received, indicating that the system sent a bad packet previously.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation An NHS rejected or failed to serve the request packet.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
|
|